Simplicity 030253-0 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur

Ce manuel convient également à

Model / Modèle / Modelo
030253
Operator’s Manual
Manuel d’utilisation
Manual del Operario
Questions? Help is just a moment away!
Vous avez des questions? Vous n'avez pas besoin
d'aller loin pour trouver de l'aide!
Preguntas? La ayuda es justa un momento lejos!
Call: Generator Helpline
Appelez: Ligne d'assistance de Générateur
Llame: Línea Directa del Generador
1-800-743-4115 M-F 8-5 CT
web: www.briggsandstratton.com
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
JEFFERSON,WISCONSIN, U.S.A.
Manual No. 198171GS
Revision 1 (11/14/2005)
Before using this product, read this
manual and follow all Safety Rules and
Operating Instructions.
WARNING
Antes de utilizar el producto, lea este
manual y siga todas las Reglas de
Seguridad e Instrucciones de Uso.
ADVERTENCIA
Avant d’utiliser ce produit, veuillez lire
le manuel et suivre toutes les directives
relatives à la sécurité et à l’utilisation.
AVERTISSEMENT
2
SAFETY RULES
TABLE OF CONTENTS
Safety Rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Know Your Generator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-12
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
EQUIPMENT
DESCRIPTION
Read this manual carefully and become
familiar with your generator. Know its
applications, its limitations and any hazards
involved.
The generator is an engine–driven, revolving field,
alternating current (AC) generator. It was designed to
supply electrical power for operating compatible electrical
lighting, appliances, tools and motor loads.The generator’s
revolving field is driven at about 3,600 rpm by a single-
cylinder engine.
CAUTION! DO NOT exceed the generator’s
wattage/amperage capacity. See “Don’t Overload
Generator”.
Every effort has been made to ensure that information in
this manual is accurate and current. However, we reserve
the right to change, alter or otherwise improve the product
and this document at any time without prior notice.
The Emission Control System for this generator is
warranted for standards set by the Environmental
Protection Agency and the California Air Resources Board.
For warranty information refer to the engine operator’s
manual.
SAFETY RULES
This is the safety alert symbol. It is used to
alert you to potential personal injury hazards.
Obey all safety messages that follow this
symbol to avoid possible injury or death.
The safety alert symbol ( ) is used with a signal word
(DANGER, CAUTION,WARNING), a pictorial and/or a
safety message to alert you to hazards. DANGER indicates
a hazard which, if not avoided, will result in death or serious
injury. WARNING indicates a hazard which, if not avoided,
could result in death or serious injury. CAUTION
indicates a hazard which, if not avoided, might result in
minor or moderate injury. CAUTION, when used
without the alert symbol, indicates a situation that could
result in equipment damage. Follow safety messages to
avoid or reduce the risk of injury or death.
Hazard Symbols and Meanings
The engine exhaust from this product contains
chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
WARNING
Fire
Explosion
Toxic Fumes
Hot Surface
Electrical Shock
Kickback
Copyright © 2005 Briggs & Stratton Power Products
Group, LLC. All rights reserved. No part of this material
may be reproduced or transmitted in any form by any
means without the express written permission of Briggs &
Stratton Power Products Group, LLC.
SAVE THESE INSTRUCTIONS
3
SAFETY RULES
This generator does not meet U. S. Coast Guard Regulation
33CFR-183 and should not be used on marine applications.
Failure to use the appropriate U. S. Coast Guard approved
generator could result in death or serious injury and/or
property damage.
WARNING
When using generator for backup power, notify utility
company. Use approved transfer equipment to isolate
generator from electric utility.
Use a ground fault circuit interrupter (GFCI) in any damp or
highly conductive area, such as metal decking or steel work.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords which are worn,
frayed, bare or otherwise damaged.
DO NOT operate generator in the rain or wet weather.
DO NOT handle generator or electrical cords while standing
in water, while barefoot, or while hands or feet are wet.
DO NOT allow unqualified persons or children to operate or
service generator.
Generator produces powerful voltage.
Failure to isolate generator from power utility
can result in death or injury to electric utility
workers due to backfeed of electrical energy.
WARNING
Operate generator ONLY outdoors.
Keep exhaust gas from entering a confined area through
windows, doors, ventilation intakes or other openings.
DO NOT operate generator inside any building or enclosure
(even if doors or windows are open), including the generator
compartment of a recreational vehicle (RV).
Running generator gives off carbon monoxide,
an odorless, colorless, poison gas.
Breathing carbon monoxide can cause nausea,
fainting or death.
WARNING
WHEN ADDING OR DRAINING FUEL
Turn generator OFF and let it cool at least 2 minutes before
removing fuel cap. Loosen cap slowly to relieve pressure in
tank.
Fill or drain fuel tank outdoors.
DO NOT overfill tank.Allow space for fuel expansion.
Keep fuel away from sparks, open flames, pilot lights, heat, and
other ignition sources.
DO NOT light a cigarette or smoke.
WHEN STARTING EQUIPMENT
Ensure spark plug, muffler, fuel cap and air cleaner are in place.
DO NOT crank engine with spark plug removed.
If fuel spills, wait until it evaporates before starting engine.
WHEN OPERATING EQUIPMENT
Do not tip engine or equipment at angle which causes fuel to
spill.
This generator is not for use in mobile equipment or marine
applications.
WHEN TRANSPORTING OR REPAIRING
EQUIPMENT
Transport/repair with fuel tank EMPTY or with fuel shutoff
valve OFF.
Disconnect spark plug wire.
WHEN STORING FUEL OR EQUIPMENT WITH FUEL
IN TANK
Store away from furnaces, stoves, water heaters, clothes
dryers or other appliances that have pilot light or other
ignition source because they can ignite fuel vapors.
Fuel and its vapors are extremely flammable and
explosive.
Fire or explosion can cause severe burns or
death.
WARNING
When starting engine, pull cord slowly until resistance is felt
and then pull rapidly to avoid kickback.
NEVER start or stop engine with electrical devices plugged in
and turned on.
Rapid retraction of starter cord (kickback) will
pull hand and arm toward engine faster than
you can let go.
Broken bones, fractures, bruises or sprains could
result.
WARNING
SAFETY RULES
4
DO NOT tamper with governed speed. Generator supplies
correct rated frequency and voltage when running at governed
speed.
DO NOT modify generator in any way.
Excessively high operating speeds increase risk of injury
and damage to generator.
Excessively low speeds impose a heavy load.
CAUTION
See “Don’t Overload Generator”.
Start generator and let engine stabilize before connecting
electrical loads.
Connect electrical loads in OFF position, then turn ON for
operation.
Turn electrical loads OFF and disconnect from generator
before stopping generator.
Exceeding generators wattage/amperage capacity can
damage generator and/or electrical devices connected
to it.
CAUTION
Use generator only for intended uses.
If you have questions about intended use, ask dealer or call
1-800-743-4115.
Operate generator only on level surfaces.
DO NOT expose generator to excessive moisture, dust, dirt,
or corrosive vapors.
DO NOT insert any objects through cooling slots.
If connected devices overheat, turn them off and disconnect
them from generator.
Shut off generator if:
-electrical output is lost;
-equipment sparks, smokes, or emits flames;
-unit vibrates excessively.
Improper treatment of generator can damage it and
shorten its life.
CAUTION
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR
GENERATOR
Disconnect the spark plug wire from the spark plug and place
the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
Use approved spark plug tester.
DO NOT check for spark with spark plug removed.
Unintentional sparking can result in fire or
electric shock.
WARNING
DO NOT touch hot surfaces and avoid hot exhaust gases.
Allow equipment to cool before touching.
Keep at least 5 ft. (152 cm) clearance on all sides of generator
including overhead.
Code of Federal Regulation (CFR) Title 36 Parks, Forests, and
Public Property require equipment powered by an internal
combustion engine to have a spark arrester, maintained in
effective working order, complying to USDA Forest service
standard 5100-1C or later revision. In the State of California a
spark arrester is required under section 4442 of the California
Public resources code. Other states may have similar laws.
Running engines produce heat.Temperature of
muffler and nearby areas can reach or exceed
150°F (65°C).
Severe burns can occur on contact.
Exhaust heat/gases can ignite combustibles,
structures or damage fuel tank causing a fire.
WARNING
KNOW YOUR GENERATOR
5
KNOW YOUR GENERATOR
Read this Operator’s Manual and safety rules before operating your generator.
Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and
adjustments. Save this manual for future reference.
120 Volt AC, 20 Amp
Duplex Receptacle
Removable Fuel Tank
Choke Lever
Recoil Starter
Rocker Switch
Circuit Breakers
(AC)
120/240 Volt AC,
30 Amp Receptacle
Air Cleaner
Grounding Fastener
Oil Fill Cap/Dipstick
Vent Knob
120 Volt AC, 20 Amp, Duplex Receptacle — May be
used to supply electrical power for the operation of
120 Volt AC, 20 Amp, single phase, 60 Hz electrical lighting,
appliance, tool and motor loads.
120/240 Volt AC, 30 Amp Locking Receptacle — May
be used to supply electrical power for the operation of
120 and/or 240 Volt AC, 30 Amp, single phase, 60 Hz
electrical lighting, appliance, tool and motor loads.
Air Cleaner — Protects engine by filtering dust and
debris out of intake air.
Choke Lever — Used when starting a cold engine.
Circuit Breakers (AC) — Each receptacle is provided
with a "push to reset" circuit breaker to protect the
generator against electrical overload.
Grounding Fastener — Consult your local agency having
jurisdiction for grounding requirements in your area.
Oil Fill Cap/Dipstick — Check and add oil to engine
here.
Recoil Starter — Used to start the engine.
Removable FuelTank — Capacity of five (5) U.S. gallons.
Easily removed for convenient refueling.
Rocker Switch — Set this switch to "On" before using
recoil starter. Set switch to "Off" to switch OFF engine.
Serial Number Label — Provides model, revision and
serial number of generator. Please have these readily
available when calling for assistance.
Vent Knob — Must be open when generator is running.
Serial Number Label
ASSEMBLY
6
ASSEMBLY
Your generator requires some assembly and is ready for
use after it has been properly serviced with the
recommended oil and fuel.
If you have any problems with the assembly of your
generator, please call the generator helpline at
1-800-743-4115. If calling for assistance, please have the
model, revision, and serial number from the serial number
label available. See “Know Your Generator” for location.
Unpacking the Generator
1. Set the carton on a rigid flat surface.
2. Remove everything from carton except generator.
3. Open carton completely by cutting each corner from
top to bottom.
4. Leave generator on carton to install handle.
Attach Handle to Unit
1. Place handle assembly onto handle supports connected
to main unit. Make sure holes in handle align with holes
on handle supports (Figure 1).
NOTE: It may be necessary to move the handle supports
from side to side in order to align the handle so it will slide
over the handle supports.
2. Insert carriage bolts through holes from outside of the
unit and attach a plastic knob from inside of unit
(Figure 2).Tighten by hand.
BEFORE STARTING THE
ENGINE
Add Engine Oil
Place generator on a level surface.
Use a long neck funnel OR remove the fuel tank as
described in “Fuel Tank”, when adding or changing oil.
Refer to engine operator’s manual and follow oil
recommendations and instructions.
NOTE: Check oil often during engine break–in. Refer to
engine operator’s manual for recommendations.
NOTE: The generator assembly rotates on a prelubricated
and sealed ball bearing that requires no additional
lubrication for the life of the bearing.
Align Holes
Handle
Handle
Supports
Figure 1 — Attach Handle to Base
Figure 2 — Secure Handle
CAUTION
Refer to engine operator’s manual for oil and fuel fill
information.
Damage to equipment resulting from failure to follow this
instruction will void warranty.
Any attempt to crank or start the engine before it has
been properly filled with the recommended oil will result
in equipment failure.
7
ASSEMBLY
Add Fuel
NOTE: This gasoline engine is certified to operate on
gasoline. Exhaust Emission Control System: EM (Engine
Modifications).
1. Use clean, fresh, regular UNLEADED fuel with a
minimum of 85 octane. DO NOT use fuel which
contains Methanol. DO NOT mix oil with fuel.
2. Clean area around fuel fill cap, remove cap.
3. Slowly add regular unleaded fuel to fuel tank. Be careful
not to overfill.Allow about 1.5" of tank space for fuel
expansion (Figure 3).
4. Install fuel cap and wipe up any spilled fuel.
Fuel Tank
As is common with all plastic fuel containers, the
removable fuel tank supplied with this generator may swell
or expand due to build-up of fuel vapors when the vent
knob is closed.This tank is designed and has been tested to
safely withstand pressure-buildup.The 'ballooning' condition
is relieved by turning the vent knob fully counterclockwise
or loosening and retightening the fuel cap/gauge.When
installing the tank on your generator, relieve tank pressure
before tightening the four large plastic wing nuts.
1. Turn the vent knob fully clockwise on the fuel gauge to
close it (Figure 4).
IMPORTANT: The vent knob should be closed whenever
you move the generator or transport the fuel tank.
WHEN ADDING FUEL
Turn generator OFF and let it cool at least 2 minutes before
removing fuel cap. Loosen cap slowly to relieve pressure in tank.
Fill fuel tank outdoors.
Fuel tank must be lying flat when filling, any other position may
cause fuel to spill.
DO NOT overfill tank.Allow space for fuel expansion.
Keep fuel away from sparks, open flames, pilot lights, heat, and
other ignition sources.
DO NOT light a cigarette or smoke.
Fuel and its vapors are extremely flammable and
explosive.
Fire or explosion can cause severe burns or
death.
WARNING
Figure 4 — Vent Knob
Vent Knob
Fuel
Tank
1.5” Air Space
Figure 3 - Fuel Expansion
AVOID SPILLING FUEL WHILE REMOVING FUEL
TANK
Turn generator OFF and let it cool at least 2 minutes before
removing fuel tank. Loosen fuel gauge slowly or open vent
knob to relieve pressure in tank.
Tighten fuel gauge and close vent knob.
Turn fuel shut off valve to the Off” position.
Disconnect the quick connect on the fuel line.
Remove the four plastic fuel tank wing nuts.
Lift fuel tank straight up.
Fuel and its vapors are extremely flammable and
explosive.
Fire or explosion can cause severe burns or
death.
WARNING
ASSEMBLY
8
2. Turn the fuel shut off valve to the Off” position
(Figure 5).
3. Disconnect the quick connect on the fuel line by
pushing on the metal tab and twisting apart (Figure 6).
Release the metal tab. Some fuel that is left in the line
will spill out.
4. Remove the four large plastic wing nuts holding the
tank onto the frame by turning them counter-
clockwise (Figure 7).
5. Lift off the fuel tank by grasping the handle (provided
on the tank) with one hand and putting the other hand
in the finger pocket (Figure 8). Lift the tank straight up.
IMPORTANT:The fuel tank MUST be filled with it lying
flat, not slanted or standing upright (Figure 9). DO NOT let
the fuel valve and quick connect come in contact with any
dirt.
To place the fuel tank back on the unit, follow these same
steps in reverse order. Make sure the four large plastic wing
nuts are tightened securely.
IMPORTANT: Remove any dirt found inside the quick
connect before putting the fuel tank back on the unit.
Make sure the vent knob is turned fully counter-
clockwise to open it. If you don’t open it, fuel will not
flow into the fuel line causing the unit to not start.
Figure 5 — Fuel Shut-off Valve
Fuel Valve is shown
in the Off” position
Fuel Tank
Figure 6 — Quick Connect
Figure 7 — Plastic Tank Wing Nuts
Figure 8 — Lifting Off Fuel Tank
Figure 9 — Fuel Tank
9
OPERATION
USING THE GENERATOR
System Ground
The generator has a system ground that connects the
generator frame components to the ground terminals on
the AC output receptacles.The system ground is connected
to the AC neutral wire (the neutral is bonded to the
generator frame).
Special Requirements
There may be Federal or State Occupational Safety and
Health Administration (OSHA) regulations, local codes, or
ordinances that apply to the intended use of the generator.
Please consult a qualified electrician, electrical inspector, or
the local agency having jurisdiction.
In some areas, generators are required to be registered
with local utility companies.
If the generator is used at a construction site, there may
be additional regulations which must be observed.
Connecting to a Building’s Electrical
System
Connections for standby power to a building’s electrical
system must be made by a qualified electrician.The
connection must isolate the generator power from utility
power, and must comply with all applicable laws and
electrical codes.
Generator Location
Generator Clearance
Place generator in a well ventilated area, which will allow
for removal of deadly exhaust gas. DO NOT place
generator where exhaust gas could accumulate and enter
inside or be drawn into a potentially occupied building.
Ensure exhaust gas is kept away from any windows, doors,
ventilation intakes or other openings that can allow exhaust
gas to collect in a confined area (Figure 10). Prevailing
winds and air currents should be taken into consideration
when positioning generator.
When using generator for backup power, notify utility
company. Use approved transfer equipment to isolate
generator from electric utility.
Use a ground fault circuit interrupter (GFCI) in any damp or
highly conductive area, such as metal decking or steel work.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords which are worn,
frayed, bare or otherwise damaged.
DO NOT operate generator in the rain or wet weather.
DO NOT handle generator or electrical cords while standing
in water, while barefoot, or while hands or feet are wet.
DO NOT allow unqualified persons or children to operate or
service generator.
Generator produces powerful voltage.
Failure to isolate generator from power utility
can result in death or injury to electric utility
workers due to backfeed of electrical energy.
WARNING
Operate generator ONLY outdoors.
Keep exhaust gas from entering a confined area through
windows, doors, ventilation intakes or other openings.
DO NOT operate generator inside any building or enclosure
(even if doors or windows are open), including the generator
compartment of a recreational vehicle (RV).
Running generator gives off carbon monoxide,
an odorless, colorless, poison gas.
Breathing carbon monoxide can cause nausea,
fainting or death.
WARNING
Figure 10 — Generator Clearance
Exhaust Port
Typical Generator Shown
Keep at least 5 ft. (152 cm) clearance on all sides of generator
including overhead.
Exhaust heat/gases can ignite combustibles,
structures or damage fuel tank causing a fire.
WARNING
OPERATION
10
OPERATING THE
GENERATOR
Starting the Engine
Disconnect all electrical loads from the generator. Follow
these start instruction steps in numerical order:
1. Make sure unit is on a level surface.
IMPORTANT: Failure to start and operate unit on a level
surface will cause the unit not to start or shut down during
operation.
2. Make sure the fuel line quick connect is hooked up and
that all four tank hold-downs are firmly tight.
3. Turn the vent knob fully counter-clockwise. See
Figure 4 on page 7.
4. Rotate the fuel valve to the On” position. See
Figure 5 on page 7.
5. Start the engine according to instructions given in the
engine operator’s manual.
NOTE: If engine starts after 3 pulls but fails to run, or if
unit shuts down during operation, make sure unit is on a
level surface and check for proper oil level in crankcase.
This unit may be equipped with a low oil protection device.
See engine operator’s manual.
Connecting Electrical Loads
Let engine stabilize and warm up for a few minutes after
starting.
Plug in and turn on the desired 120 and/or 240 Volt AC,
single phase, 60 Hz electrical loads.
DO NOT connect 240 Volt loads to the 120 Volt duplex
receptacles.
DO NOT connect 3–phase loads to the generator.
DO NOT connect 50 Hz loads to the generator.
DO NOT OVERLOAD THE GENERATOR. See
“Don’t Overload Generator”.
See “Don’t Overload Generator”.
Start generator and let engine stabilize before connecting
electrical loads.
Connect electrical loads in OFF position, then turn ON for
operation.
Turn electrical loads OFF and disconnect from generator
before stopping generator.
Exceeding generators wattage/amperage capacity can
damage generator and/or electrical devices connected
to it.
CAUTION
When starting engine, pull cord slowly until resistance is felt
and then pull rapidly to avoid kickback.
NEVER start or stop engine with electrical devices plugged in
and turned on.
Rapid retraction of starter cord (kickback) will
pull hand and arm toward engine faster than
you can let go.
Broken bones, fractures, bruises or sprains could
result.
WARNING
DO NOT touch hot surfaces and avoid hot exhaust gases.
Allow equipment to cool before touching.
Keep at least 5 ft. (152 cm) clearance on all sides of generator
including overhead.
Code of Federal Regulation (CFR) Title 36 Parks, Forests, and
Public Property require equipment powered by an internal
combustion engine to have a spark arrester, maintained in
effective working order, complying to USDA Forest service
standard 5100-1C or later revision. In the State of California a
spark arrester is required under section 4442 of the California
Public resources code. Other states may have similar laws.
Running engines produce heat.Temperature of
muffler and nearby areas can reach or exceed
150°F (65°C).
Severe burns can occur on contact.
Exhaust heat/gases can ignite combustibles,
structures or damage fuel tank causing a fire.
WARNING
11
OPERATION
Stopping the Engine
1. Turn off and unplug all electrical loads from generator
panel receptacles. NEVER start or stop engine with
electrical devices plugged in and turned on.
2. Let engine run at no–load for 30 seconds to stabilize
internal temperatures of engine and alternator.
3. Turn engine off according to instructions given in
engine operator’s manual.
4. Move fuel valve to Off” position.
RECEPTACLES
120/240 Volt AC, 30 Amp, Locking
Receptacle
Use a NEMA L14–30 plug with this receptacle. Connect a
4–wire cord set rated for 250 Volt AC loads at 30 Amps (or
greater) (Figure 11).You can use the same 4–wire cord if
you plan to run a 120 Volt load.
This receptacle powers 120/240 Volt AC, 60 Hz, single
phase loads requiring up to 2,775 watts of power at
23.1 Amps for 120 Volts; 5,550 watts of power (5.55 kW)
at 23.1 Amps for 240 Volts.The outlet is protected by a
push–to–reset circuit breaker.
120 Volt AC, 20 Amp, Duplex
Receptacles
Each duplex receptacle (Figure 12) is protected against
overload by a push–to–reset circuit breaker.
Use each receptacle to operate 120 Volt AC, single–phase,
60 Hz electrical loads requiring up to 2,400 watts (2.4 kW)
at 20 Amps of current. Use cord sets that are rated for
125 Volt AC loads at 20 Amps (or greater).
Figure 12 — 120 Volt, 20 Amp Duplex Receptacle
NEVER attempt to power a device requiring more amperage
than generator or receptacle can supply.
DO NOT overload the generator. See “Don’t Overload
Generator”.
Receptacles may be marked with rating value greater
than generator output capacity.
CAUTION
Figure 11 — 120/240 Volt AC, 30 Amp Receptacle
4-Wire Cord Set
240V
120V
120V
W (Neutral)
X (Hot)
Y (Hot)
NEMA L14-30
Ground (Green)
OPERATION
12
DON'T OVERLOAD
GENERATOR
Capacity
You must make sure your generator can supply enough
rated (running) and surge (starting) watts for the items you
will power at the same time. Follow these simple steps:
1. Select the items you will power at the same time.
2. Total the rated (running) watts of these items.This is
the amount of power your generator must produce to
keep your items running. See Figure 13.
3. Estimate how many surge (starting) watts you will
need. Surge wattage is the short burst of power
needed to start electric motor-driven tools or
appliances such as a circular saw or refrigerator.
Because not all motors start at the same time, total
surge watts can be estimated by adding only the
item(s) with the highest additional surge watts to the
total rated watts from step 2.
Example:
Total Rated (Running) Watts = 3075
Highest Additional Surge Watts = 1800
Total Generator Output Required = 4875
Power Management
To prolong the life of your generator and attached devices,
it is important to take care when adding electrical loads to
your generator.There should be nothing connected to the
generator outlets before starting it's engine.The correct
and safe way to manage generator power is to sequentially
add loads as follows:
1. With nothing connected to the generator, start the
engine as described in this manual.
2. Plug in and turn on the first load, preferably the largest
load you have.
3. Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly.
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
NEVER add more loads than the generator capacity.Take
special care to consider surge loads in generator capacity,
as described above.
*Wattages listed are approximate only. Check tool or
appliance for actual wattage.
Tool or Appliance
Rated (Running)
Watts
Additional Surge
(Starting) Watts
Window Air
Conditioner
1200 1800
Refrigerator 800 1600
Deep Freezer 500 500
Television 500 -
Light (75 Watts) 75 -
3075 Total
Running Watts
1800 Highest
Surge Watts
Tool or Appliance
Rated*
(Running)
Watts
Additional
Surge
(Starting)
Watts
Essentials
Light Bulb - 75 watt
75
-
Deep Freezer
500
500
Sump Pump
800
1200
Refrigerator/Freezer - 18 Cu. Ft.
800
1600
Water Well Pump - 1/3 HP
1000
2000
Heating/Cooling
Window AC - 10,000 BTU
1200
1800
Window Fan
300
600
Furnace Fan Blower - 1/2 HP
800
1300
Kitchen
Microwave Oven - 1000 Watt
1000
-
Coffee Maker
1500
-
Electric Stove - Single Element
1500
-
Hot Plate
2500
-
Family Room
DVD/CD Player
100
-
VCR
100
-
Stereo Receiver
450
-
Color Television - 27”
500
-
Personal Computer w/17” monitor
800
-
Other
Security System
180
-
AM/FM Clock Radio
300
-
Garage Door Opener - 1/2 HP
480
520
Electric Water Heater - 40 Gallon
4000
-
DIY/Job Site
Quartz Halogen Work Light
1000
-
Airless Sprayer - 1/3 HP
600
1200
Reciprocating Saw
960
960
Electric Drill - 1/2 HP
1000
1000
Circular Saw - 7 1/4”
1500
1500
Miter Saw - 10”
1800
1800
Table Planer - 6”
1800
1800
Table Saw/Radial Arm Saw - 10”
2000
2000
Air Compressor - 1-1/2 HP
2500
2500
Figure 13 - Wattage Reference Chart
SPECIFICATIONS AND MAINTENANCE
13
SPECIFICATIONS
Starting Wattage . . . . . . . . . . . . . . . . . . . . . . .8,550 watts
Wattage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5,550 watts
AC Load Current:
At 120 Volts . . . . . . . . . . . . . . . . . . . . . . . . .46.2 Amps
At 240 Volts . . . . . . . . . . . . . . . . . . . . . . . . .23.1 Amps
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–phase
Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . .60 Hertz
Fuel Tank Capacity . . . . . . . . . . . . . . . . . . . . 5 U.S. gallons
Shipping Weight . . . . . . . . . . . . . . . . . . . . . . . . . . 176 lbs.
GENERAL MAINTENANCE
RECOMMENDATIONS
The Owner/Operator is responsible for making sure that
all periodic maintenance tasks are completed on a timely
basis; that all discrepancies are corrected; and that the unit
is kept clean and properly stored. NEVER operate a
damaged or defective generator.
NOTE: Should you have questions about replacing
components on your Briggs & Stratton Power Products
generator, please call 1-800-743-4115 for assistance.
Engine Maintenance
See engine operator’s manual for instructions.
KEEP OUT OF REACH OF CHILDREN. DON'T
POLLUTE. CONSERVE RESOURCES. RETURN
USED OIL TO COLLECTION CENTERS.
Generator Maintenance
Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with snow,
leaves or any other foreign material.
NOTE: DO NOT use a garden hose to clean generator.
Water can enter engine fuel system and cause problems. In
addition, if water enters generator through cooling air slots,
some of the water will be retained in voids and cracks of
the rotor and stator winding insulation.Water and dirt
buildup on the generator internal windings will eventually
decrease the insulation resistance of these windings.
Generator Cleaning
Use a damp cloth to wipe exterior surfaces clean.
Use a soft bristle brush to loosen caked on dirt or oil.
Use a vacuum cleaner to pick up loose dirt and debris.
Use low pressure air (not to exceed 25 psi) to blow
away dirt. Inspect cooling air slots and opening on
generator.These openings must be kept clean and
unobstructed.
Used motor oil has been shown to cause skin cancer in
certain laboratory animals.
Thoroughly wash exposed areas with soap and water.
Avoid prolonged or repeated skin contact with used
motor oil.
CAUTION
DO NOT expose generator to excessive moisture, dust, dirt,
or corrosive vapors.
DO NOT insert any objects through cooling slots.
Improper treatment of generator can damage it and
shorten its life.
CAUTION
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR
GENERATOR
Disconnect the spark plug wire from the spark plug and place
the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
Use approved spark plug tester.
DO NOT check for spark with spark plug removed.
Unintentional sparking can result in fire or
electric shock.
WARNING
STORAGE
14
STORAGE
The generator should be started at least once every seven
days and allowed to run at least 30 minutes. If this cannot
be done and you must store the unit for more than
30 days, use the following guidelines to prepare it for
storage.
Generator Storage
Clean the generator as outlined in “To Clean the
Generator.
Check that cooling air slots and openings on generator
are open and unobstructed.
Engine Storage
See engine operator’s manual for instructions.
Other Storage Tips
Always store unit with fuel shut off valve in the Off
position (Figure 5, earlier).
To prevent gum from forming in fuel system or on
essential carburetor parts, empty entire contents of both
supplied fuel stabilizer containers into fuel tank and fill
with fresh fuel. Run the unit for several minutes to
circulate the additive through the carburetor.The unit
and fuel can then be stored for up to 24 months.
Additional fuel stabilizer can be purchased locally.
Fuel tank may swell in storage if vent is closed.When
storing generator with fuel in the tank, make sure the
vent knob is turned fully counter-clockwise.
Store unit in clean and dry area.
DO NOT place a storage cover over a hot generator.
Let equipment cool for a sufficient time before placing the
cover on the equipment.
Storage covers can be flammable.
WARNING
TROUBLESHOOTING
15
TROUBLESHOOTING
Problem Cause Solution
Engine is running, but no AC
output is available.
1. Circuit breaker is open.
2. Poor connection or defective cord
set.
3. Connected device is bad.
4. Fault in generator.
1. Reset circuit breaker.
2. Check and repair.
3. Connect another device that is in
good condition.
4. Contact local service facility.
Engine runs good but bogs down
when loads are connected.
1. Short circuit in a connected load.
2. Generator is overloaded.
3. Shorted generator circuit.
1. Disconnect shorted electrical load.
2. See "Don't Overload Generator".
3. Contact local service facility.
Engine will not start; or starts and
runs rough.
1. Fuel valve is in the "Off" position.
2. Vent knob in fuel gauge is closed.
3. Quick connect in fuel line is
disconnected.
4. Out of gasoline.
1. Turn fuel valve to the "On"
position.
2. Open vent knob in fuel gauge.
3. Reconnect quick connect in fuel
line.
4. Fill fuel tank.
Engine shuts down during
operation.
Out of gasoline. Fill fuel tank.
Engine lacks power.
Load is too high. See "Don't Overload Generator".
16
NOTES
NOTES
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC EQUIPMENT OWNER WARRANTY POLICY
LIMITED WARRANTY
Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the equipment that is defective in material
or workmanship or both. Transportation charges on product submitted for repair or replacement under this warranty must be borne by
purchaser. This warranty is effective for the time periods and subject to the conditions stated below. For warranty service, find the nearest
Authorized Service Dealer in our dealer locator map at www.briggspowerproducts.com.
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM PURCHASE, OR TO THE EXTENT PERMITTED BY LAW ANY
AND ALL IMPLIED WARRANTIES ARE EXCLUDED. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARE EXCLUDED
TO THE EXTENT EXCLUSION IS PERMITTED BY LAW. Some states or countries do not allow limitations on how long an implied warranty
lasts, and some states or countries do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation
and exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state
to state or country to country.
OUR EQUIPMENT*
OUTBOARD
MOTOR
PRESSURE
WASHER
WATER PUMP
(Not available in the
USA)
PORTABLE
GENERATOR
WELDER
LLeessss tthhaann 1100 KKWW 1100 KKWW oorr ggrreeaatteerr
TTrraannssffeerr sswwiittcchh
2 years
none
1 year
90 days
1 year
90 days
2 years
1 year
2 years
none
3 years or
1500 hours
none
3 years
none
WARRANTY PERIOD**
HOME STANDBY GENERATOR SYSTEM
Consumer Use
Commercial Use
* The engine and starting batteries are warranted solely by the manufacturers of those products.
** 2 years for all consumer products in the European Union. Parts only on 2nd year for consumer use of Portable Generator and
Home Standby Generator System - Less than 10 KW, outside of European Union.
The warranty period begins on the date of purchase by the first retail consumer or commercial end user, and continues for the period of time
stated in the table above. “Consumer use" means personal residential household use by a retail consumer. “Commercial use" means all other
uses, including use for commercial, income producing or rental purposes. Once equipment has experienced commercial use, it shall thereafter
be considered as commercial use for purposes of this warranty. Equipment used for prime power in place of utility are not applicable to
this warranty. Electric powered pressure washers used for commercial purposes are not warranted.
NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS & STRATTON PRODUCTS. SAVE YOUR
PROOF OF PURCHASE RECEIPT. IF YOU DO NOT PROVIDE PROOF OF THE INITIAL PURCHASE DATE AT THE TIME WARRANTY
SERVICE IS REQUESTED, THE MANUFACTURING DATE OF THE PRODUCT WILL BE USED TO DETERMINE THE WARRANTY
PERIOD.
ABOUT YOUR WARRANTY
We welcome warranty repair and apologize to you for being inconvenienced. Any Authorized Service Dealer may perform warranty repairs. Most
warranty repairs are handled routinely, but sometimes requests for warranty service may not be appropriate. For example, warranty service would not
apply if equipment damage occurred because of misuse, lack of routine maintenance, shipping, handling, warehousing or improper installation.
Similarly, the warranty is void if the manufacturing date or the serial number on the equipment has been removed or the equipment has been altered
or modified. During the warranty period, the Authorized Service Dealer, at its option, will repair or replace any part that, upon examination, is found to
be defective under normal use and service. This warranty will not cover the following repairs and equipment:
Normal Wear: Outdoor Power Equipment, like all mechanical devices, needs periodic parts and service to perform well. This warranty does not
cover repair when normal use has exhausted the life of a part or the equipment.
Installation and Maintenance: This warranty does not apply to equipment or parts that have been subjected to improper or unauthorized
installation or alteration and modification, misuse, negligence, accident, overloading, overspeeding, improper maintenance, repair or storage so as,
in our judgment, to adversely affect its performance and reliability. This warranty also does not cover normal maintenance such as adjustments,
fuel system cleaning and obstruction (due to chemical, dirt, carbon, lime, etc.).
Other Exclusions: This warranty excludes wear items such as quick couplers, oil gauges, belts, o-rings, filters, pump packing, etc., pumps that
have been run without water supplied or damage or malfunctions resulting from accidents, abuse, modifications, alterations, or improper servicing
or freezing or chemical deterioration. Accessory parts such as guns, hoses, wands and nozzles are excluded from the product warranty. This
warranty excludes failures due to acts of God and other force majeure events beyond the manufacturers control. Also excluded is used,
reconditioned, and demonstration equipment; equipment used for prime power in place of utility power and equipment used in life support
applications.
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
JEFFERSON, WI, USA
Effective September 1, 2004 replaces all undated Warranties and all Warranties dated before September 1, 2004
RÈGLES DE SÉCURITÉ
18
TABLE DES MATIÈRES
Règles de Sécurité. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16-18
Connaissez Votre Générateur . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Assemblage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-21
Opération . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22-26
Entretien . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Rangement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Dépannage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Garantie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
DESCRIPTION DE L ÉQUIPEMENT
Lisez avec soin ce manuel et familiarisez-vous avec
votre générateur. Connaissez ses applications, ses
limitations et les dangers qu'il implique.
Ce générateur est un générateur entraîné par un moteur à champ
magnétique rotatif produisant du courant alternatif (c.a.). Il a été
conçu pour fournir du courant électrique pour faire marcher des
charges compatibles d'éclairage, d'appareils ménagers, d'outil et de
moteur. Le champ tournant du générateur est entraîné à
3,600 T/M par un moteur monocylindrique.
ATTENTION! NE PAS dépasser la capacité en watts ou en
Ampères du générateur.Voir "Ne Pas Surcharger le Générateur"
pour l'information spécifique.
Tout a été mis en oeuvre pour que les informations contenues
dans ce manuel soient exactes et à jour. Cependant, nous se
réserve le droit de changer, d'altérer ou d'améliorer le produit à
n'importe quel moment sans avis préalable.
Le Système de contrôle de l'émission du générateur est garanti pour
des normes établies par L'Agence de protection de l'environnement
et le California Air Resources Board. Pour des informations sur la
garantie, se reporter au manuel d'utilisation du moteur.
RÈGLES DE SÉCURITÉ
Ceci est la sûreté le symbole vif. Il est utilisé pour
vous alerter aux dangers de blessure personnels
potentiels. Obéir tous messages de sûreté qui suivent
ce symbole éviter la blessure ou la mort possibles.
Le symbole indiquant un message de sécurité est accompagné d'un
mot indicateur (DANGER,ATTENTION,AVERTISSEMENT), d'un
message illustré et/ou d'un message de sécurité visant à vous
avertir des dangers. DANGER indique un danger qui, s'il n'est pas
évité, provoquera des blessures graves, voire fatales.
AVERTISSEMENT indique un danger qui, s'il n'est pas évité, peut
provoquer des blessures graves, voire fatales. ATTENTION
indique un danger qui, s'il n'est pas évité, peut provoquer des
blessures mineures ou légères. Le mot ATTENTION, lorsqu'il est
utilisé sans le symbole d'alerte, indique une situation pouvant
endommager l'équipement. Suivez les messages de sécurité pour
éviter ou réduire les risques de blessures ou de mort.
Symboles de Danger et Moyens
L’échappement du moteur de ce produit contient des produits
chimiques que l’État de Californie considère comme causant le
cancer, des déformations à la naissance ou d’autres dangers
concernant la reproduction.
AVERTISSEMENT
Feu
Explosion
Emanations Toxiques
Surface Chaude
Choc Électrique
Recul
VEUILLEZ CONSERVER CES INSTRUCTIONS
RÈGLES DE SÉCURITÉ
19
Faites fonctionner le générateur SEULEMENT à l'extérieur.
Évitez que les gaz d'échappement entrent dans un espace restreint,
par une fenêtre, une porte, une prise d'aération ou toute autre
ouverture.
NE FAITES PAS fonctionner le générateur à l'intérieur d'un bâtiment
ou d'un abri (même si les fenêtres et les portes sont ouvertes), y
compris à l'intérieur du compartiment d'un véhicule de plaisance.
Le générateur, lorsqu'il fonctionne, produit du monoxyde
de carbone, un gaz toxique inodore et incolore.
Le fait de respirer du monoxyde de carbone provoque
des nausées, des évanouissements ou peut être fatal.
AVERTISSEMENT
Lorsque vous utilisez le générateur comme source d'énergie de
secours, il est nécessaire d'aviser les services publics d'électricité.
Utilisez un disjoncteur différentiel lorsque vous utilisez l'appareil dans
des endroits humides ou extrêmement conductibles, comme les
terrasses en métal ou les ouvrages métalliques.
NE touchez pas les fils dénudés ou les boîtiers.
N'UTILISEZ pas le générateur avec des cordons électriques usés,
effilochés ou dénudés, ou abîmés de quelque sorte que ce soit.
N'UTILISEZ pas le générateur sous la pluie.
NE manipulez pas le générateur ou les cordons d'alimentation lorsque
vous êtes debout dans l'eau, pieds nus ou avec les mains ou les pieds
humides.
NE laissez pas des personnes non qualifiées ou des enfants se servir
ou réparer le générateur.
Le générateur produit une tension élevée.
NE PAS isoler le générateur de l'installation électrique
risque de provoquer des blessures ou même d'être fatal
pour les ouvriers électriciens et de causer des dommages
au générateur dus à un "backfeed" d'énergie électrique.
AVERTISSEMENT
Cette génératrice ne satisfait pas aux normes U. S. Coast Guard
Regulation 33CFR-183 et ne doit pas être utilisée pour des
applications marines.
L'omission d'utiliser une génératrice appropriée et approuvée par U. S.
Coast Guard pourrait entraîner des blessures corporelles ou des
dommages matériels.
AVERTISSEMENT
LORS DE L'AJOUT OU DE LA VIDANGE DU
CARBURANT
Éteignez le générateur et laissez-le refroidir au moins 2 minutes avant
de retirer le capuchon du réservoir de carburant. Desserrez lentement
le capuchon pour laisser la pression s'échapper du réservoir.
Remplissez ou vidangez le réservoir d'essence à l'extérieur.
NE REMPLISSEZ PAS trop le réservoir. Laissez l'expansion de
l'essence.
Éloignez l'essence des étincelles, des flammes, des veilleuses, de la
chaleur et de toute autre source d'inflammation.
N'ALLUMEZ PAS de cigarette ou ne fumez pas à proximité de l'appareil.
LORS DU DÉMARRAGE DE L'ÉQUIPEMENT
Assurez-vous que la bougie d'allumage, le silencieux, le bouchon à
essence et le filtre à air sont en place.
NE démarrez PAS le moteur lorsque la bougie d'allumage est enlevée.
Si du carburant est renversé, attendez qu'il s'évapore avant de
démarrer le moteur.
LORSQUE L'ÉQUIPEMENT FONCTIONNE
NE penchez PAS le moteur ou l'équipement, vous risqueriez de
renverser de l'essence.
Cette génératrice n'est pas conçue pour être utilisée dans de
l'équipement mobile ou les applications marines.
LORSQUE VOUS TRANSPORTEZ OU RÉPAREZ
L'ÉQUIPEMENT
Le réservoir d'essence doit être VIDE ou le robinet d'arrêt de
carburant doit être à la position fermée (OFF) pendant le transport
ou la réparation.
Débranchez le câble de bougie.
LORSQUE VOUS ENTREPOSEZ L'ESSENCE OU UN
ÉQUIPEMENT AVEC UN RÉSERVOIR À ESSENCE
Entreposez-le loin des appareils de chauffage, des fours, des chauffe-
eau, des sécheuses ou de tout autre appareil électroménager
disposant d'une veilleuse ou de toute autre source d'inflammation
risquant d'enflammer les vapeurs d'essence.
L'essence et ses vapeurs sont extrêmement
inflammables et explosives.
Le feu ou l'explosion risque de provoquer des
blessures graves, pouvant être fatales.
AVERTISSEMENT
Lors du démarrage du moteur, tirez lentement sur la corde jusqu'à ce
que vous sentiez une résistance et tirez alors rapidement afin d'éviter
un effet de recul.
NE démarrez JAMAIS ni n'arrêtez jamais le moteur alors que des
appareils électriques y sont branchés et en fonction.
Une rétroaction rapide de la corde du démarreur
(effet de recul) tirera votre main et votre bras vers le
moteur plus rapidement que vous ne pouvez relâcher
la corde.
Vous risquez ainsi de subir des fractures, des
ecchymoses ou des entorses.
AVERTISSEMENT
RÈGLES DE SÉCURITÉ
20
NE TRAFIQUEZ PAS la vitesse régulée. Le générateur produit une
fréquence nominale et une tension correctes lorsqu'il fonctionne à
une vitesse régulée.
NE modifiez le générateur d'aucune façon.
Les vitesses de fonctionnement excessivement élevées
augmentent les risques de blessure ou risquent d'endommager
le générateur.
Les vitesses extrêmement lentes entraînent une charge importante.
ATTENTION
Voir la section " Ne Pas Surcharger Générateur ".
Démarrez le générateur et laissez le moteur se stabiliser avant de
brancher les charges électriques.
Branchez les charges électriques en position ARRÊT, puis, remettez en
position MARCHE.
Éteignez les charges électriques et débranchez-les du générateur avant
de l'arrêter.
Dépasser la capacité de puissance ou d'ampérage du
générateur risque d'endommager ce dernier et/ou les autres
appareils électriques qui y sont branchés.
ATTENTION
NE vous servez du générateur que pour les utilisations prévues.
Si vous avez des questions concernant les utilisations prévues,
demandez à votre distributeur ou appelez 1-800-743-4115.
Ne faites fonctionner le générateur que sur des surfaces horizontales.
N'EXPOSEZ pas le générateur à une humidité excessive, à de la
poussière, à de la saleté ou à des vapeurs corrosives.
N'INSÉREZ aucun objet dans les fentes de refroidissement.
Si les appareils branchés sont en surchauffe, éteignez-les et
débranchez-les du générateur.
Arrêtez le générateur si :
-la puissance électrique est inexistante;
-l'équipement produit des étincelles, de la fumée ou des flammes;
-l'unité vibre excessivement.
Un traitement inapproprié du générateur risque de
l'endommager et de raccourcir sa durée d'utilisation.
ATTENTION
LORSQUE VOUS RÉGLEZ OU RÉPAREZ VOTRE
GÉNÉRATEUR
Débranchez toujours le câble de bougie et placez-le de façon à ce
qu'il ne soit pas en contact avec la bougie.
LORS DE TESTS D'ALLUMAGE DU MOTEUR
Utilisez un vérificateur de bougies d'allumage approuvé.
NE vérifiez PAS l'allumage lorsque la bougie d'allumage est enlevée.
Unintentional peut résulter dans feu ou électrique.
AVERTISSEMENT
NE TOUCHEZ PAS aux pièces chaudes et évitez le contact avec les
gaz d’échappement.
Laissez l'équipement refroidir avant de le toucher.
Laissez un dégagement d’au moins 1,52 m (5 pi) tout autour de la
génératrice, y compris au-dessus.
Le Code of Federal Regulation (CFR) Title 36 Parks, Forests, and Public
Property exige que de l’équipement alimenté par un moteur à
combustion interne soit doté d’un pare-étincelles et constamment
maintenu en bon état fonctionnement, conformément à la norme de
service 5100-1C de la USDA Forest ou à une révision de celle-ci. Dans
l’État de la Californie, un pare-étincelles est requis en vertu de la section
4442 du California Public Resources Code. Il se peut que d’autres États
aient des lois semblables.aux terres fédérales. Si vous équipez le silencieux
d'un pare-étincelles, il doit être en bon état de fonctionnement.
Les moteurs en fonctionnement produisent de la
chaleur. La température du silencieux et des endroits
à proximité peuvent atteindre, voire dépasser 150°F
(65°C).
Le contact de ces pièces risque de causer de graves
brûlures.
La chaleur et les gaz d’échappement peuvent
enflammer des matériaux combustibles et les
structures ainsi que causer des dommages au
réservoir d’essence et entraîner un incendie.
AVERTISSEMENT
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Simplicity 030253-0 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur
Ce manuel convient également à