TIM31X/TIM32X | SICK 8018590/ZP97/2017-07-27 • Subject to change without notice • SICK AG • Waldkirch • Germany • www.sick.com5
Model Name TiM310-1030000 (part no. 1052627)
TiM310-1130000 (part no. 1056550)
TIM310-0130000S02 (part no. 1069932)
TIM310-1030000S02 (part no. 1062221)
TIM310-1130000S02 (part no. 1067917)
TiM320-1031000 (part no. 1063467)
TiM320-1131000 (part no. 1062219)
TiM320-0131000S02 (part no. 1069933)
TiM320-1131000S02 (part no. 1067919)
Max. pulse
duration
0.5 ns
Field evaluation
1 evaluation case with 1 eld set (3 elds).
Signaling of eld infringements via a
combination of 3 switching outputs.
Number of eld
sets
TiM31x: 16 with 3 congurable elds each
TiM32x: 16 with 3 exible congurable elds
each
Aux interface
USB 2.0, for conguration
Switching inputs PNP: 4 x IN (U
e
= max. 28 V, I
e
= max. 5 mA),
opto-decoupled, debouncing time approx.
10 ms
NPN: Common reference potential 9 ... 28 V
Switching outputs 4 x OUT (each I
a
≤ 100 mA), not galvanically
isolated from the supply voltage, short-circuit
protected/temperature protected
Congurable for OUT 1 .... OUT 3:
Response time (134 ms ... 30 s)
Holding time (0 ms ... 10 s)
2)
Electrical
connections
1 x 0.9 m cable (+10 %) with 15-pin D-Sub-HD
plug
1 x 0.8 m cable (+10 %) with 12-pin M12 plug
1 x micro USB socket, type B (covered)
Function key Teach-in (eld set 1 eld contour)
Optical indicators 2 x LED
Supply voltage DC 9 ... 28 V, SELV and PELV according to
IEC 60364-4-41: 2005-12
Power
consumption
4 W (for unloaded switching outputs)
16 W (with four loaded switching outputs)
Housing Lower part: Die-cast aluminum
Optics hood: Polycarbonate with scratch-proof
coating
Weight
Approx. 150 g without cables
Electrical safety
According to IEC 61010-1 (ed.3)
Protection class
III according to EN 61140: 2006-08
IEC 61010-1 (ed.3)
Enclosure rating
IP 65 (EN 60529: 1991-10/A2: 2000-02)
EMC
Radiated emission: Residential area according
to EN 61000-6-3: 2007-01
Electromagnetic immunity: Industrial
environment according to
EN 61000-6-2: 2005-08
Vibration
resistance
According to EN 60068-2-6: 2008-02
Shock resistance
According to EN 60068-2-27: 2009-05
Ambient
temperature
Operation: –10 ... +50 °C
Storage: –30 ... +70 °C
Temperature
change
According to EN 60068-2-14: 2009-07
Damp heat
According to EN 60068-2-30: 2005-12
Air humidity
< 80%
Installation height
< 5,000 m above sea level
Ambient condi-
tions
According to EN 61010-1:2011-07, contamina-
tion level 3 outside housing
1) Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to
to Laser Notice No. 50 of June 2007
2) The TiM has an internal, system-related time delay of 67 ms.
Assignment of infringed elds - switching outputs
Fields of a eld set Switching outputs
OUT 1 OUT 2 OUT 3
Fields 1, 2, and 3 infringed Active
Active Active
Fields 2 and 3 infringed
Deacti-
vated
Active Active
Field 3 infringed
Deacti-
vated
Deacti-
vated
Active
All elds free
Deacti-
vated
Deacti-
vated
Deacti-
vated
Field 1: inner, eld 2: center, eld 3: outer
Active: in working position; deactivated: in resting position
Output level
• PNP: The level of the switching outputs OUT 1 ... OUT 3 is
active low (in resting position: high, in working position: low
(eld infringed)).
• NPN: The level of the switching outputs OUT 1 ... OUT 3 is
active high (in resting position: low, in working position:
high (eld infringed)).
All elds of a eld set are also deemed to be infringed during
switching on, booting, in the event of an error, and when the
device is switched off.
The OUT 4 switching output works with the following levels:
Function Level PNP Level NPN
Device Ready High Low
Index signal (15 Hz), corresponds to
measurement at 90°
Low-Peaks High-Peaks
Errors Low High
Technical specications
Model Name TiM310-1030000 (part no. 1052627)
TiM310-1130000 (part no. 1056550)
TIM310-0130000S02 (part no. 1069932)
TIM310-1030000S02 (part no. 1062221)
TIM310-1130000S02 (part no. 1067917)
TiM320-1031000 (part no. 1063467)
TiM320-1131000 (part no. 1062219)
TiM320-0131000S02 (part no. 1069933)
TiM320-1131000S02 (part no. 1067919)
Scanning range
Radial, aperture angle 270°
Scanning fre-
quency
15 Hz (15 scans/s)
Response time
Typical 134 ms (2 scans)
Scanning range
0.05 m ... 4 m; typically 2 m at 10 % remission
Remission
Typical 4 % ... > 1,000 % (reector)
Physical minimum
object size
(cross-section)
112 mm for a scanning range of 4 m,
61 mm for a scanning range of 2 m and 10 %
remission
Measuring error
Statistical (1 s): 30 mm
Systematic: ± 40 mm
Temperature drift 0.5 mm/K
Ambient light
immunity
80,000 lx
Light source
Laser diode, infrared (λ = 850 nm)
Device laser class
Laser class 1 according to EN 60825-1:
2014
1)
, eye-safe
Max. radiation
power
2.0 W
For further technical specications, see the Online data sheet
on the product website (www.sick.com/tim3xx)
a WARNING
Risk of potential equalization currents
The TiM is designed to be operated in a system with proper
grounding of all connected devices and mounting surfaces
to the same ground potential. If this condition is not met,
potential equalization currents may through along the cable
shields, causing the following hazards:
• Dangerous contact voltage on the metal housing
• Malfunction or destruction of the TiM
• Heating of the cables with possible spontaneous
combustion.
> See the "Electrical Installation" chapter in the & Technical
Information (no. 8014318) on the product website (www.
sick.com/tim3xx) for measures for eliminating hazards.
a ATTENTION
Risques liés à des courants d’équipotentialité
Le TiM a été conçu pour être utilisé dans une installation
prévoyant une mise à la terre correcte de tous les appareils
et surfaces de montage raccordés sur un même potentiel
de sol. Si cette condition n’est pas remplie, des courants
d’équipotentialité risquent dans certaines conditions de
passer par les blindages des câbles et d’exposer aux risques
suivants :
• tension de contact dangereuse sur le boitier en métal,
• comportement incorrect ou destruction du TiM.
• chauffe des câbles jusqu’à leur inammation spontanée.
> Pour des mesures de prévention de tels risques, voir le
chapitre « Installation électrique » de & l’Information tech-
nique (no. 8014318) ou sur la page produit sur internet
(www.mysick.com/en/tim3xx).
Field set factory settings - switching inputs
Field
set
Switching inputs Field shape
Default size of eld 1
IN 1 IN 2 IN 3 IN 4
1 0 0 0 0
Rectangle
1) 2)
, segmented
L: 1 m, W: 2 m
2 1 0 0 0
Rectangle
1) 2)
, segmented
L: 1.25 m, W: 2 m
3 0 1 0 0
Rectangle
1) 2)
, segmented
L: 1.5 m, W: 2 m
4 1 1 0 0
Rectangle
1) 2)
, segmented
L: 1.75 m, W: 2 m
5 0 0 1 0
TiM31x: Semi-circle
3)
,
radius: 0.75 m
TiM32x: Rectangle
1)
, seg-
mented L: 1 m, W: 2 m
6 1 0
1 0 TiM31x: Semi-circle
3)
,
radius: 1 m
TiM32x: Rectangle
1)
, seg-
mented L: 1.25 m, W: 2 m
7 0 1
1 0 TiM31x: Semi-circle
3)
,
radius: 1.5 m
TiM32x: Rectangle
1)
, seg-
mented L: 1.5 m, W: 2 m
8 1 1 1
0 TiM31x: Semi-circle
3)
,
radius: 2 m
TiM32x: Rectangle
1)
, seg-
mented L: 1.75 m, W: 2 m
9 0 0 0 1
Rectangle
1) 4)
, segmented
L: 1 m, W: 2 m
10 1 0 0 1
Rectangle
1) 4)
, segmented
L: 1.25 m, W: 2 m
11 0 1 0 1
Rectangle
1) 4)
, segmented
L: 1.5 m, W: 2 m
12 1 1 0 1
Rectangle
1) 4)
, segmented
L: 1.75 m, W: 2 m
13 0 0 1 1
Rectangle
1) 4)
, segmented
L: 1 m, W: 2 m
14 1 0 1 1
Rectangle
1) 4)
, segmented
L: 1.25 m, W: 2 m
15 0 1 1 1
Rectangle
1) 4)
, segmented
L: 1.5 m, W: 2 m
16 1 1 1 1
Rectangle
1) 4)
, segmented
L: 1.75 m, W: 2 m
L = length, W = width
1) Default setting, starting shape can be modied as required
2) TiM31x: Field 2 limits = eld 1 limits plus 25 %, relationship cannot be changed
Field 3 limits = eld 1 limits plus 52 %, relationship cannot be changed
3) TiM31x: Default settings:
Field 2 limits = eld 1 limits plus 25 %, limits can be adjusted freely
Field 3 limits = eld 1 limits plus 52 %, limits can be adjusted freely
4) TiM32x: Default setting, starting shape can be modied as required
Input level
• PNP: Low (in resting position): ≤ 2 V, high (in working
position): ≥ 8 V
• NPN: Active low (in working position): ≤ (IN 9...28 V) – 8 V,
inactive high (in resting position) > (IN 9...28 V) – 2 V