Enbrighten 60226 Manuel utilisateur

Taper
Manuel utilisateur
In-Wall
Smart
Fan Control
60226
ZWA4014
Suppliers Declaration of Conformity | Model #: 60226 | Jasco Products Co., 10 E. Memorial Rd., Oklahoma City, OK
73114, byjasco.com
This device complies with Part 15 of the FCC and Industry Canada license-exempt RSS standards. Operation is
subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.
FCC NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized
modifications to this equipment. Such modifications could void the user’s authority to operate the equipment
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy,
and if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined by turning
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Consult the dealer or an experienced radio/TV technician for help.
See product label for FCC/IC certification numbers.
CAN ICES-3(B)/NMB-3(B)
FCC/IC
WARNING/ADVERTENCIA/AVERTISSEMENT
FEATURES
IMPORTANT! The fixture controlled by the Z-Wave in-wall smart fan control must not
exceed ratings. The fan control is designed only for use with permanently installedxtures.
Get to you know your Z-Wave smart fan control
Turn ON/OFF and adjust fan speed levels manually or remotely via the Z-Wave controller
Can be included in multiple groups and scenes
May be used in single-pole installation or with up to two Enbrighten, UltraPro orJascoPro
Series add-on switches in 3-way or 4-way wiring congurations
Uses a standard, toggle-style wallplate for single-gang installations (wallplate
not included)
Blue LED indicates switch location in a dark room
Screw terminal installation – requires wiring connections for line (hot), load, neutral and
ground. Traveler wire required for 3-way installation
This Z-Wave device has advanced features that allow you to customize your experience.
These features can only be adjusted by a Z-Wave enabled controller that supports the
Z-Wave configuration command class. For a complete list of adjustable configurations,
visit www.ezzwave.com/config
NOTE: This smart device only controls the fan motor and does not control any lighting
connected to the fan. If your fan has an integrated light, a second switch must be installed
to control the lighting directly. No more than two identical fans should be connected to the
fan control. The total load of the fan(s) should not exceed 1/10hp(75W), motor.
WARRANTY/GARANTÍA/GARANTIE
Jasco Products Company warrants this product to be free from manufacturing defects for five years from the original
date of consumer purchase. This warranty is limited to the repair or replacement of this product only and does not
extend to consequential or incidental damage to other products that may be used with this product. This warranty is in
lieu of all other warranties, expressed or implied. Some states do not allow limitations on how long an implied warranty
lasts or permit the exclusion or limitation of incidental or consequential damage, so the above limitations may not apply
to you. This warranty gives you specific rights and you may also have other rights which vary from state to state. Please
contact our U.S.-based Consumer Care at 1-800-654-8483 (option 1) between 7AM–8PM, M-F, Central Time or
byjasco.com if the unit should prove defective within the warranty period.
ZWA4014
Voltage: 120Vac, 60Hz
Signal (frequency): 908.4/916MHz
Maximum loads: 1/10hp(75W), motor no more than two identical fans to the switch. Not to exceed 1/10hp(75W), motor resistive load.
CONTROLS FAN MOTOR ONLY. For use only with split-capacitor or shaded-pole ceiling fan motors.
Operating temperature range: 0-40° C
For indoor use only
Specifications subject to change without notice due to continuing product improvement
SPECIFICATIONS — IMPORTANT!
MADE IN CHINA
Distributed by Jasco Products Company LLC, 10 E. Memorial Rd., Oklahoma City, OK 73114.
This Jasco product comes with a 5-year limited warranty. Visit byjasco.com for warranty details.
Questions? Contact our U.S.-based Consumer Care at 1-800-654-8483 7AM-8PM, M-F, Central Time.
©Jasco 2022 | ZWA4014 | 60226 | 06/02/22 v1
All brand names shown are trademarks of their respective owners
Z-WAVE INTEROPERABILITY
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from
other manufacturers and/or other applications. All non-battery operated nodes within the network will act as
repeaters regardless of vendor to increase reliability of the network.
This device supports association command class (3 Groups)
Association Group 1 supports Lifeline, Binary Switch Report
Association Group 2 supports Basic Set and is controlled by pressing the ON or OFF button with the local load
Association Group 3 supports Basic Set and is controlled by double pressing the ON or OFF button
Each Association Group supports 5 total nodes
3-WAY CONFIGURATION
The smart device is set to work with add-on switches by default. To use with a
standard 3-way switch, follow the steps below.
1. Pull out the air gap switch
2. While pressing the top paddle, push in the air gap switch
3. Continue pressing the top paddle until the LED flashes yellow three times to
indicate standard 3-way switch configuration
4. Repeat these steps to return to the add-on switch setting – LED flashes blue
three times
ADD-ON SWITCH COMPATIBLE
Enbrighten, UltraPro and JascoPro Series add-on switches support the same
features as the Z-Wave device, such as single-, double- and triple-tap functions,
from all locations. It also allows operation from up to five locations and provides a
uniform appearance.
Visit Jasco.com to purchase add-on switches.
ADJUST FAN SPEED
The LED indicator conrms fan speed settings by flashing patterns
LOW – LED will blink every two seconds for 10 seconds
MEDIUM – LED will blink every second for 10 seconds
HIGH – LED will blink every half second for 10 seconds
1. To decrease fan speed, press and hold lower rocker.
2. To increase fan speed, press and hold upper rocker.
NOTE: This switch only controls the fan motor and does not control any lighting
that may be part of the fan control. If your fan has an integrated light, a second
light switch will need to be installed separately to control the lighting load
directly. No more than two identical fans should be controlled by one switch. The
total load of the fan(s) should not exceed 1/10hp(75W), motor maximum.
RÉGLAGE DE LA VITESSE DU VENTILATEUR
Le voyant à DEL confirme les réglages du ventilateur en respectant une série de clignotements.
Vitesse faible (LOW) La DEL clignote toutes les deux secondes pendant 10 secondes
Vitesse moyenne (MEDIUM) La DEL clignotant toutes les secondes pendant 10 secondes
Vitesse élevée (HIGH) La DEL clignote toutes les demi-secondes pendant 10 secondes
1. Pour diminuer la vitesse du ventilateur : Appuyez sur la partie inrieure de l’interrupteur
basculant, et maintenez-la enfoncée.
2. Pour augmenter la vitesse du ventilateur : Appuyez sur la partie supérieure de linterrupteur
basculant, et maintenez-la enfoncée.
REMARQUE: Cet interrupteur commande le moteur du ventilateur uniquement; il ne
commande pas le module déclairage qui pourrait faire partie de la commande de lappareil.
Dans le cas des ventilateurs avec module déclairage intégré, un second interrupteur doit être
installé séparément pour assurer la commande directe de la charge déclairage. Pas plus de
deux ventilateurs identiques pour un interrupteur. Assurez-vous que la charge totale du ou des
ventilateurs branchés nexcède pas 2.5 ampère.
CONFIGURACIÓN DE 3 VÍAS
El dispositivo inteligente escongurado para funcionar con interruptores
auxiliares de manera predeterminada. Para usarlo con un interruptor de 3 vías
esndar, siga los pasos a continuación.
1. Desconecte el interruptor de espacio de aire
2. Mientras presiona la paleta superior, empuje el interruptor de espacio de aire
3. Siga presionando la paleta superior hasta que la luz LED parpadee de color
amarillo tres veces para indicar la configuración de interruptor de 3 vías
esndar
4. Repita estos pasos para volver a la conguración de interruptor auxiliar. La luz
LED parpadea de color azul tres veces
COMPATIBLE CON INTERRUPTOR AUXILIAR
Los interruptores auxiliares Enbrighten, UltraPro y JascoPro Series son
compatibles con las mismas caractesticas que el dispositivo Z-Wave, como
funciones de una pulsación, dos pulsaciones o tres pulsaciones, desde todas las
ubicaciones. También permite la operación desde hasta cinco ubicaciones y
ofrece una apariencia uniforme.
Visite Jasco.com para comprar interruptores auxiliares.
AJUSTE DE LA VELOCIDAD DEL VENTILADOR
El indicador LED confirma cuál es la velocidad del ventilador según el tipo de parpadeo.
BAJA: la luz LED parpadeará cada 2 segundos durante 10 segundos
MEDIA: la luz LED parpadeará cada segundo durante 10 segundos
ALTA: la luz LED parpadeará cada medio segundo durante 10 segundos
1. Para disminuir la velocidad del ventilador: presione sin soltar el interruptor basculante
inferior.
2. Para aumentar la velocidad del ventilador: presione sin soltar el interruptor basculante
superior.
NOTA: El interruptor solo controla el motor del ventilador, no los dispositivos de iluminación
que puedan ser parte de dicho control. Si el ventilador cuenta con una lámpara integrada, será
necesario instalar un segundo interruptor por separado para controlar la carga de la luz
directamente. Un interruptor solo podrá controlar un máximo de dos ventiladores idénticos. La
carga total del ventilador o ventiladores no deberá ser superior a 1/10hp(75W), motor.
HECHO EN CHINA
Distribuido por Jasco Products Company LLC, 10 E. Memorial Rd., Oklahoma City, OK 73114.
Este producto de Jasco tiene una garantía limitada de 5 años. Visite byjasco.com para conocer los
detalles de la garantía.
©Jasco 2022 | ZWA4014 | 60226 | 06/02/22 v1
CARACTÉRISTIQUES
IMPORTANT! Lappareil contrôle intelligent du ventilateur montage mural Z-Wave ne doit pas
dépasser les caractéristiques nominales. Lcontrôle du ventilateur est conçu pour être utilisé
uniquement avec des appareils d’éclairage installés de fon permanente.
Familiarisez-vous avec lutilisation de votre contrôle intelligent du ventilateur Z-Wave
Turn ON/OFF and adjust fan speed levels manually or remotely via the Z-Wave controller
Can be included in multiple groups and scenes
May be used in single-pole installation or with up to two Enbrighten, UltraPro orJascoPro
Series add-on switches in 3-way or 4-way wiring configurations
Se xe sur une plaque murale de type bascule standard pour des installations à
compartiment unique (plaque murale non incluse).
Blue LED indicates switch location in a dark room
Screw terminal installation requires wiring connections for line (hot), load, neutral and
ground. Traveler wire required for 3-way installation
This Z-Wave device has advanced features that allow you to customize your experience.
These features can only be adjusted by a Z-Wave enabled controller that supports the
Z-Wave configuration command class. For a complete list of adjustable configurations, visit
www.ezzwave.com/cong
NOTE: This smart device only controls the fan motor and does not control any lighting
connected to the fan. If your fan has an integrated light, a second switch must be installed to
control the lighting directly. No more than two identical fans should be connected to the fan
control. The total load of the fan(s) should not exceed 1/10hp(75W), motor.
ZWA4014
Signal (fréquence) : 908.4/916MHz
Charges maximales : 1/10hp(75W), motor no more than two identical fans to the switch. Not to exceed 1/10hp(75W), motor resistive load.
CONTROLS FAN MOTOR ONLY. For use only with split-capacitor or shaded-pole ceiling fan motors.
Plage de températures de fonctionnement : 0-40° C
Utilisation intérieure uniquement
Les caractéristiques techniques peuvent être modifiées sans préavis en raison de lamélioration continue des
produits
CARACTÉRISTIQUES TECHNIQUES — IMPORTANT!
WARNING — SHOCK HAZARD
Turn OFF the power to the branch circuit for the device fixture at the service panel. All wiring
connections must be made with the power OFF to avoid personal injury and damage to the device.
This device is intended for installation in accordance with the National Electric Code and local
regulations in the United States or the Canadian Electrical Code and local regulations in Canada. If you
are unsure or uncomfortable about performing this installation, consult a qualified electrician.
SINGLE-SWITCH WIRING
STANDARD 3-WAY SWITCH WIRING
1. Connect green/bare wire to the GROUND terminal.
2. Connect the black wire from the light to either LINE/LOAD terminal.
3. Connect the black wire from the power source (hot) to the other LINE/LOAD terminal.
4. Connect the white wire to the NEUTRAL terminal – use jumper if necessary.
NOTE: The traveler terminal is only used for multi-switch wiring and is not used in a two-way
system (one switch and one load).
5. Secure the device into the switch box with the provided mounting screws ensure wires
are not pinched or crushed.
6. Install the wallplate.
LINE SIDE (Z-WAVE DEVICE)
1.
2. Remove line side wallplate
3. Remove switch from line side switch box – DO NOT disconnect wires
4. Label wire from the power source LINE
5. Label one remaining wire traveler 1 – note the color of this wire for installation
of the 3-way switch
6. Label the other remaining wire traveler 2
7. Disconnect all wires from the switch
8. Connect green/bare wire to the GROUND terminal
9. Connect the line wire to either LINE/LOAD terminal
10. Connect the traveler 1 wire to the other LINE/LOAD terminal
11. Connect the traveler 2 wire to the TRAVELER terminal
12. Connect one end of a jumper to the bundle of neutral wires using a wire nut
13. Connect the other end of the jumper to the NEUTRAL terminal
14. Secure the device into the switch box with the provided mounting screws –
ensure wires are not pinched or crushed
15. Install the wallplate
LOAD SIDE (3-WAY SWITCH)
1. Remove load side wallplate
2. Remove switch from load side switch box DO NOT disconnect wires
3. Label wire from the light LOAD
4. Label traveler 1 wire recall the wire color from the Z-Wave device installation
5. Label traveler 2 wire
6. Disconnect all wires from the switch
TRAVELER
LOAD/LINE
LOAD/LINE
NEUTRAL
GROUND
DD
LINE
LOAD
GROUND
NEUTRAL
JUMPER
C
C
B
B
A
A
Typical wiring schematic for 3-way installation
Line side (hot) Load side
C
H H
LINE
LINE
TRAVELER 2
TRAVELER 1
GROUND
TRAVELER 2
LINE
TRAVELER 1
C
H H
Load
Scan code for
alternate 3-way
wiring process
Z-Wave device on line side with standard 3-way switch
7. Connect green/bare wire to the GROUND terminal
8. Connect the load wire to the traveler 1 wire using a wire nut
9. Connect traveler 2 to the LINE (hot) terminal
10. Connect one end of a jumper to the bundle of neutral wires using a wire nut
11. Connect the other end of the jumper to the COMMON terminal
12. Secure the 3-way switch into the switch
box ensure wires are not pinched or crushed
13. Install the wallplate
14. Apply power to the fuse box or circuit
breaker
WIRING REQUIREMENTS
Attach using the enclosures holes, strip insulation 5/8in. (16mm).
UL specifies the tightening torque for the screws is 12lbf-in (14Kgf-cm).
CYCLE LED
The LED behind the fan control acts as a guide
light or status indicator.
How to cycle through options:
1. Press menu button forve seconds
2. Press up three times and down one time quickly
indicator flashes blue
3. Push the toggle up:
A. Once for LED ON when the load is OFF
illuminates orange to confirm
B. Twice for LED ON when the load is ON
illuminates yellow to confirm
C. Three times for always OFF – illuminates
pink to confirm
D. Four times for always ON – illuminates
purple to confirm
4. Press menu button once to save – indicator
flashes green twice
CHANGE LED INDICATOR COLOR
The LED indicator color can be changed from
the device.
1. Press menu button forve seconds
2. Press toggle up once and down once once LED
illuminates in selected color
3. Press top or bottom paddle to cycle through
color options:
Red
Orange
Yellow
Green
4. Press menu button once to save – indicator
flashes green twice
Insert wires into holes, DO NOT wrap wires around screws
DO NOT remove screws
IMPORTANT! The Z-Wave device operates with add-on switches by default. To install it with a standard 3-way switch, follow the steps under 3-way configuration. The instructions below are for wiring a standard 3-way switch. See the add-on switch manual to
install add-on switches.
Tous les noms de marque sont des marques de commerce de leurs propriétaires respectifs
INTEROPÉRABILI ENTRE LES DISPOSITIFS Z-WAVE
Ce produit peut être utilisé dans un réseau Z-Wave avec dautres appareils certifiés Z-Wave produits par
d’autres fabricants et dautres applications. Tous les nœuds fonctionnant sans pile au sein du seau joueront
le rôle de répétiteurs, quel que soit le fournisseur, afin de rehausser la fiabilité du réseau.
Cet appareil prend en charge la classe de commandes Association (trois groupes)
Le groupe d’association 1 prend en charge la ligne de sécurité et le rapport Binary Switch
Le groupe d’association 2 prend en charge le réglage de base et est commandé par une pression du bouton
de marche et d’arrêt par la charge locale
Le groupe d’association 3 prend en charge le réglage de base et est commandé par une double pression du
bouton de marche et darrêt
Chaque groupe d’association prend en charge un total de cinq (5) nœuds
CONFIGURATION À TROIS VOIES
Parfaut, lappareil intelligent est configuré pour fonctionner avec des interrupteurs
supplémentaires. Pour l’utiliser avec un interrupteur à trois voies standard, suivez les
étapes présentées ci-après.
1. Tirez sur l’interrupteur à entrefer.
2. Pendant que vous appuyez sur la palette supérieure, tirez sur linterrupteur à entrefer.
3. Continuez dappuyer sur la palette supérieure jusquà ce que le voyant à DEL jaune
clignote trois fois, ce qui indique la conguration à trois voies standard.
4. Répétez ces étapes pour revenir aux paramètres de linterrupteur supplémentaire – le
voyant à DEL bleu clignote trois fois.
COMPATIBLE AVEC LES INTERRUPTEURS COMPLÉMENTAIRES
Les interrupteurs supplémentaires Enbrighten, UltraPro et JascoPro Series prennent en
charge les mêmes caractéristiques que lappareil Z-Wave, comme les fonctions à simple,
double et triple touche, à tous les emplacements. Ils sont également opérationnels dans un
Visitez Jasco.com pour acheter des interrupteurs supplémentaires.
CARACTERÍSTICAS
¡IMPORTANTE! El aparato controlado por el control inteligente de ventiladores Z-Wave no
debe superar las clasificaciones. El control de ventiladores esdiseñado exclusivamente
para uso con aparatos de instalación permanente.
Familiarizarse con su control inteligente de ventiladores Z-Wave
Turn ON/OFF and adjust fan speed levels manually or remotely via the Z-Wave controller
Can be included in multiple groups and scenes
May be used in single-pole installation or with up to two Enbrighten, UltraPro orJascoPro
Series add-on switches in 3-way or 4-way wiring configurations
Utiliza una placa de pared de tipo palanca para instalaciones de cajas de un solo módulo
(placa de pared no incluida)
Blue LED indicates switch location in a dark room
Screw terminal installation – requires wiring connections for line (hot), load, neutral and
ground. Traveler wire required for 3-way installation
This Z-Wave device has advanced features that allow you to customize your experience.
These features can only be adjusted by a Z-Wave enabled controller that supports the
Z-Wave configuration command class. For a complete list of adjustable configurations,
visit www.ezzwave.com/config
NOTE: This smart device only controls the fan motor and does not control any lighting
connected to the fan. If your fan has an integrated light, a second switch must be installed
to control the lighting directly. No more than two identical fans should be connected to the
fan control. The total load of the fan(s) should not exceed 1/10hp(75W), motor.
ZWA4014
Voltaje: 120Vac, 60Hz
Señal (frecuencia): 908.4/916MHz
Cargas máximas: 1/10hp(75W), motor no more than two identical fans to the switch. Not to exceed 1/10hp(75W), motor resistive load.
CONTROLS FAN MOTOR ONLY. For use only with split-capacitor or shaded-pole ceiling fan motors.
Rango de temperatura de funcionamiento: 0-40° C
Para uso en espacios interiores solamente
Las especificaciones están sujetas a cambio sin aviso debido a la mejora continua de productos
ESPECIFICACIONES ¡IMPORTANTE!
Thank you for your purchase!
Instructions
made easy
Read instructions
or watch easy-to-
follow video.
Register your
product
Receive exclusive
deals and register
your product.
For additional Enbrighten products, visit
our website www.Jasco .com.
Like our product?
Leave a review on your favorite
retailer website or amazon.com.
Having problems?
Let us know how we can help.
Call 1-800-654-8483 between
7AM-8PM, M-F, Central Time.
Scan code or visit yjasco.com/60226i. Scan code or visit byjasco.com/deals.
A. LINE - Black wire/black screw (input)
B. LOAD - Black wire/black screw (output)
C. GROUND -
Green or bare wire/green screw
D. JUMPER - White wire/silver screw
TRAVELER
LOAD/LINE
LOAD/LINE
NEUTRAL
GROUND
Load
A. LINE - Black wire/black screw
B. TRAVELER 1 - Black wire/black screw (output)
C. TRAVELER 2 - Red wire/brass screw (traveler)
D. GROUND - Green or bare wire/green screw
E. JUMPER - White wire/silver screw
C
H H
D
D
EE
C
C
C
B
B
A
A
B
B
A
D
C
TRAVELER 2
TRAVELER 2
LINE
TRAVELER 1
TRAVELER 1
NEUTRAL GROUND
GROUND
JUMPER
LINE
LINE
Scan QR code below if there isn't
a line bundle in the switch box
Blue (default)
Pink
Purple
White
Todos los nombres de marcas son marcas comerciales de sus respectivos propietarios
INTEROPERABILIDAD DE Z-WAVE
Este producto se puede incluir y operar en cualquier red Z-Wave con otros dispositivos Z-Wave certificados
de otros fabricantes u otras aplicaciones. Todos los nodos que no son alimentados por pilas dentro de la
red servin como repetidores sin importar cual sea el proveedor para aumentar la conabilidad de la red.
Este dispositivo admite la clase de comando de asociación (3 grupos)
Grupo de asociación 1 admite informes de conmutador binario de la red vital (Lifeline)
Grupo de asociación 2 admite la configuración básica y se controla presionando el botón de encendido o
apagado con la carga local
Grupo de asociación 3 admite la configuración básica y se controla presionando dos veces el bon de
encendido o apagado
Cada grupo de asociación admite 5 nodos en total
FABRIQ EN CHINE
Distribué par Jasco Products Company LLC, 10 East Memorial Rd, Oklahoma City, OK 73114.
Ce produit Jasco a une garantie limitée de cinq ans. Visitez le site byjasco.com pour obtenir des détails
sur la garantie.
Des questions? Veuillez communiquer avec notre service à la clientèle aux États-Unis au 1-800-654-8483, de
© Jasco 2022 | ZWA4014 | 60226 | 06/02/22 v1
Jasco Products Company garantiza que este producto estará libre de defectos de fabricación durante cinco años a partir
de la fecha de compra original del consumidor. Esta garantía se limita a la reparación o el reemplazo solo de este
producto y no se extiende a daños consecuentes o incidentales a otros productos que puedan usarse con este producto.
Esta garantía se otorga en lugar de todas las demás garantías expresas o implícitas. Algunos estados no permiten
limitaciones a la duración de una garantía implícita ni permiten la exclusión de daños incidentales o consecuentes, por lo
que las limitaciones anteriores pueden no aplicarse a usted. Esta garantía le otorga derechos especos y posiblemente
tiene otros derechos que pueden variar de un estado a otro. Comuníquese con nuestro Servicio al Consumidor con sede
resulta defectuosa dentro del período de garantía.
Jasco Products Company garantit que ce produit est exempt de toutfaut de fabrication pour cinq ans à compter de la
date de lachat original par lacheteur. Cette garantie se limite exclusivement à la réparation ou au remplacement de ce
produit et nest pas applicable aux dommages indirects ou accessoires survenus sur dautres produits utilisés avec ce
produit. Cette garantie se substitue à toute autre garantie expresse ou implicite. Certains États ne permettent pas de
restrictions quant à la durée dune garantie implicite ou permettent l’exclusion ou la limitation des dommages indirects et
accessoires; il se peut, par conséquent, que cette garantie ne sapplique pas dans votre cas. Cette garantie vous confère
des droits juridiques précis; vous pouvez jouir dautres droits qui peuvent varier d’un État à lautre. Veuillez communiquer
ou sur byjasco.com si lappareil devient défectueux pendant la période de garantie.
Declaración de conformidad de proveedores | Modelo n.º:
60226
| Jasco Products Co., 10 E. Memorial Rd., Oklahoma
City, OK 73114, byjasco.com
El funcionamiento depende de las dos condiciones siguientes: (1) este dispositivo no puede causar interferencias
perjudiciales, y (2) este dispositivo debe aceptar toda interferencia recibida, incluyendo las que puedan causar
un funcionamiento no deseado.
NOTA DE LA FCC: El fabricante no asume ninguna responsabilidad por las interferencias de radio o televisión causadas
por modificaciones no autorizadas en este equipo. Este tipo de modificaciones podría anular la autoridad del usuario
para operar el equipo
NOTA: Este equipo se sometió a pruebas y se considera que cumple con los límites de un dispositivo digital de clase B,
de conformidad con la parte 15 de las normas de la FCC. Estos límites están diseñados para proporcionar una
proteccn razonable contra la interferencia perjudicial en una instalación residencial. Este equipo genera,
usa y puede irradiar enera de radiofrecuencia. Si no se instala y usa de acuerdo con estas instrucciones, podrá causar
interferencia perjudicial a las radiocomunicaciones. Por otro lado, tampoco es posible garantizar que
no ocurrirán interferencias en una instalación en particular. En caso de que este equipo cause interferencias perjudiciales
en la recepción de radio o televisión, algo que puede determinarse apagando y encendiendo el equipo, se recomienda
al usuario que intente corregir las interferencias aplicando una o varias de las siguientes medidas:
Cambiar la orientación o ubicación de la antena receptora.
Aumentar la distancia entre el equipo y el receptor.
Conectar el equipo a la salida de un circuito diferente al cual esconectado el receptor.
Consultar al distribuidor o a un técnico de radio/TV experimentado para obtener ayuda.
Vea la etiqueta del producto para conocer los números de certificación FCC/IC.
CAN ICES-3(B)/NMB-3(B)
60226
| Jasco Products Co., 10 E. Memorial Rd., Oklahoma City,
OK 73114, byjasco.com
brouillage préjudiciable; et 2) cet appareil doit accepter toutes les interrences reçues, notamment les interférences qui
peuvent provoquer un fonctionnement non dési.
Le fabricant nest pas responsable des interrences sur les fréquences radioélectriques ou
télévisuelles pouvant être causées par des modifications non autorisées de cet appareil. De telles modifications peuvent
annuler le droit de l’utilisateur à utiliser cet appareil.
REMARQUE :
contre le brouillage préjudiciable en milieu résidentiel. Cet appareil produit, utilise et peut émettre des ondes de
fréquence radio et, s’il nest pas installé et utilisé conformément aux instructions, il peut provoquer un brouillage
préjudiciable aux communications radio. Il nexiste toutefois aucune garantie que des interrences ne se produiront pas
dans une installation donnée. Si cet appareil provoque un brouillage préjudiciable à la réception radiophonique ou
télévisuelle (ce qui peut être vérié en lallumant et en léteignant), nous encourageons l’utilisateur à essayer de corriger
Réorienter ou déplacer l’antenne de réception.
Augmenter la distance entre lappareil et le récepteur.
Consultez le détaillant ou un technicien qualifié en radio/télévision pour obtenir de laide.
Voir létiquette du produit pour les numéros de certification FCC/IC.
CAN ICES-3(B)/NMB-3(B)
RISK OF FIRE
RISK OF ELECTRICAL SHOCK
RISK OF BURNS
CONTROLLING APPLIANCES
CAUTION: TO REDUCE THE RISK OF OVERHEATING AND POSSIBLE DAMAGE TO OTHER EQUIPMENT, DO
NOT INSTALL TO CONTROL A RECEPTACLE, MOTOR-OPERATED APPLIANCE, FLUORESCENT LIGHTING
FIXTURE OR A TRANSFORMER-SUPPLIED APPLIANCE.
DO NOT EXCEED RATINGS
DO NOT USE TO CONTROL ANY DEVICE WHERE UNINTENDED OPERATION COULD CAUSE
UNSAFE CONDITIONS (HEAT LAMP, SUN LAMP, ETC.)
NOT FOR USE WITH MEDICAL OR LIFE-SUPPORT EQUIPMENT
FOR INDOOR USE ONLY
RIESGO DE INCENDIO
RIESGO DE DESCARGA ECTRICA
RIESGO DE QUEMADURAS
CONTROL DE EQUIPOS ELECTRODOMÉSTICOS PRECAUCIÓN: A FIN DE DISMINUIR EL RIESGO
DE RECALENTAMIENTO Y DE POSIBLES DAÑOS EN LOS DEMÁS EQUIPOS, NO INSTALAR PARA
CONTROLAR APARATOS QUE FUNCIONAN A MOTOR, ARTEFACTOS DE ILUMINACIÓN DE LUZ
FLUORESCENTE O APARATOS ALIMENTADOS CON TRANSFORMADORES.
NO SUPERE LOS VALORES NOMINALES ECTRICOS
NO USAR PARA CONTROLAR DISPOSITIVOS
SE PROHÍBE SU EMPLEO EN EQUIPO MÉDICO O EQUIPO PARA EL MANTENIMIENTO DE LAS
FUNCIONES VITALES
USE SOLAMENTE EN INTERIORES
RISQUE D’INCENDIE
RISQUE DE CHOC ÉLECTRIQUE
RISQUE DE BRÛLURES
COMMANDE DES APPAREILS ATTENTION : POUR RÉDUIRE LE RISQUE DE SURCHAUFFE ET DE DOMMAGES
POSSIBLES À D’AUTRES APPAREILS, NE PAS INSTALLER POUR COMMANDER UN APPAREIL ACTIONNÉ PAR MOTEUR,
UN APPAREIL D’ÉCLAIRAGE FLUORESCENT OU UN APPAREIL ALIMENPAR
UN TRANSFORMATEUR.
NE PAS PASSER LES CARACTÉRISTIQUES NOMINALES
NE PAS UTILISER POUR COMMANDER DES APPAREILS POUR LESQUELS UN FONCTIONNEMENT IMPRÉVU
POURRAIT ENTRNER DES CONDITIONS DANGEREUSES (LAMPE À RAYONS INFRAROUGES, LAMPE
SOLAIRE, ETC.)
NE PAS UTILISER AVEC UN ÉQUIPEMENTDICAL OU DE SURVIE
POUR UTILISATION INTÉRIEURE UNIQUEMENT
REMOVE SINGLE-POLE SWITCH
1.
the circuit at the
circuit breaker or
fuse box.
IMPORTANT! Verify
power to switch box
is OFF before
continuing.
2. Remove
wallplate.
3. Remove the
switch mounting
screws.
4. Carefully remove
the switch from
the switch box –
DO NOT
disconnect
the wires.
5. Identify the following wires in the switch box:
A. Ground – Green/bare
B. Line (hot) – Black (connected to power)
C. Load – Black (connected to lighting)
D. Neutral – White
6. Disconnect the wires from the existing switch – label wires according to the
previous terminal connections.
Old switch
Out to light (load)
From breaker box
LINE
LOAD
GROUND
NEUTRAL
C
B
D
A
ADDING YOUR DEVICE TO A Z-WAVE NETWORK
1. Follow the instructions for your Z-Wave certified controller to add a device to
the Z-Wave network.
2. Once the controller is ready to add your device, push the toggle up or down.
You have complete control to turn your fixture ON/OFF according to groups,
scenes, schedules and interactive automations programmed by your controller.
If your Z-Wave certified controller features remote access, you can control your
fixture from your mobile devices.
If prompted by the controller to enter the S2 security code, refer to the QR
code/security number on the side of the box or the QR code label on the product
(see Figure 1). Enter the 5-digit code.
Figure 1:
TO REMOVE AND RESET THE DEVICE
1. Follow the instructions for your Z-Wave certified controller to remove a device
from the Z-Wave network.
2. Once the controller is ready to remove your device, push the toggle up or down.
TO RETURN YOUR SWITCH TO FACTORY DEFAULTS
1. Slide the air gap switch right.
2. While pressing the OFF (bottom) button, push the air gap left and continue
pressing the OFF button. The LED flashes through the eight colors once.
NOTE: This should only be used if your network’s primary controller is missing or
otherwise inoperable.
NOTE: SmartStart enabled products can be added into a Z-Wave network by
scanning the QR code on the product with a controller providing SmartStart
inclusion. No further action is required and the SmartStart product will be added
automatically within 10 minutes of being switched on in the network vicinity.
Z-W AVE DSK
PIN: XXXXX
DSK :
XXXX X
-25651-2267 1
-26939-4759 9
-19612-2587 2
-47752
A. Ground (Green/bare)
B. Line or load (Black)
C. Line or load (Black)
D. Traveler (Red/other)
E. Neutral (White)
F. Up — press &
release to turn fan
on, press & hold to
increase fan speed
G. Down — press &
release to turn fan
decrease fan speed
H. Menu button
I. Air gap switch — slide the
air gap switch right to
disconnect the power.
Push it left for normal
operation.
A
B
C
D
E
F
GI
H
A
B
C
D
E
A
B
C
D
E
F
GI
H
F
GI
H
A. Tierra (verde/pelado)
B. Línea o carga (negro)
C. Línea o carga (negro)
D. Viajero (rojo/otro)
E. Neutro (blanco)
F. Up — press &
release to turn fan
on, press & hold to
increase fan speed
G. Down press &
release to turn fan
decrease fan speed
H. Bon de menú
I. Interruptor de espacio de
aire: deslice el interruptor
del espacio de aire hacia
la derecha para
desconectar la fuente de
alimentación. Presiónelo
hacia la izquierda para un
funcionamiento normal.
A. Terre – (l vert/l nu)
B. Secteur ou charge (noir)
C. Secteur ou charge (noir)
D. Pendentif (l rouge/autre
couleur)
E. Neutre (blanc)
F. Up — press & release to turn
fan on, press & hold to increase
fan speed
G. Down — press & release to turn
fan speed
H. Bouton de menu
I. Interrupteur à entrefer glissez
l'interrupteur à entrefer vers la
droite pour couper
l'alimentation. Poussez-le vers la
gauche pour un
fonctionnement normal.
El dispositivo inteligente escongurado para funcionar con interruptores
auxiliares de manera predeterminada. Para usarlo con un interruptor de 3 vías
estándar, siga los pasos a continuación.
1. Desconecte el interruptor de espacio de aire
2. Mientras presiona la paleta superior, empuje el interruptor de espacio de aire
3. Siga presionando la paleta superior hasta que la luz LED parpadee de color
amarillo tres veces para indicar la configuración de interruptor de 3 vías
esndar
4. Repita estos pasos para volver a la configuración de interruptor auxiliar. La luz
LED parpadea de color azul tres veces
COMPATIBLE CON INTERRUPTOR AUXILIAR
Los interruptores auxiliares Enbrighten, UltraPro y JascoPro Series son
compatibles con las mismas características que el dispositivo Z-Wave, como
funciones de una pulsación, dos pulsaciones o tres pulsaciones, desde todas las
ubicaciones. También permite la operación desde hasta cinco ubicaciones y
ofrece una apariencia uniforme.
Visite Jasco.com para comprar interruptores auxiliares.
El indicador LED confirma cuál es la velocidad del ventilador según el tipo de parpadeo.
BAJA: la luz LED parpadeará cada 2 segundos durante 10 segundos
MEDIA: la luz LED parpadeará cada segundo durante 10 segundos
ALTA: la luz LED parpadeará cada medio segundo durante 10 segundos
1. Para disminuir la velocidad del ventilador: presione sin soltar el interruptor basculante
inferior.
2. Para aumentar la velocidad del ventilador: presione sin soltar el interruptor basculante
superior.
NOTA: El interruptor solo controla el motor del ventilador, no los dispositivos de iluminación
que puedan ser parte de dicho control. Si el ventilador cuenta con una lámpara integrada, será
necesario instalar un segundo interruptor por separado para controlar la carga de la luz
directamente. Un interruptor solo podrá controlar un máximo de dos ventiladores idénticos. La
carga total del ventilador o ventiladores no deberá ser superior a 1/10hp(75W), motor.
7. Connect green/bare wire to the GROUND terminal
8. Connect the load wire to the traveler 1 wire using a wire nut
9. Connect traveler 2 to the LINE (hot) terminal
10. Connect one end of a jumper to the bundle of neutral wires using a wire nut
11. Connect the other end of the jumper to the COMMON terminal
12. Secure the 3-way switch into the switch
box – ensure wires are not pinched or crushed
13. Install the wallplate
14. Apply power to the fuse box or circuit
breaker
CYCLE LED
The LED behind the fan control acts as a guide
light or status indicator.
How to cycle through options:
1. Press menu button for five seconds
2. Press up three times and down one time quickly
indicator ashes blue
3. Push the toggle up:
A. Once for LED ON when the load is OFF –
illuminates orange to confirm
B. Twice for LED ON when the load is ON
illuminates yellow to confirm
C. Three times for always OFF – illuminates
pink to confirm
D. Four times for always ON – illuminates
purple to confirm
4. Press menu button once to save indicator
ashes green twice
CHANGE LED INDICATOR COLOR
The LED indicator color can be changed from
the device.
1. Press menu button for five seconds
2. Press toggle up once and down once once LED
illuminates in selected color
3. Press top or bottom paddle to cycle through
color options:
Red
Orange
Yellow
Green
4. Press menu button once to save indicator
flashes green twice
Este dispositivo admite la clase de comando de asociación (3 grupos)
Grupo de asociación 1 admite informes de conmutador binario de la red vital (Lifeline)
Grupo de asociación 2 admite la configuración básica y se controla presionando el bon de encendido o
apagado con la carga local
Grupo de asociación 3 admite la conguracn básica y se controla presionando dos veces el bon de
encendido o apagado
Cada grupo de asociación admite 5 nodos en total
120Vac, 60Hz
Construction of control: Independently Mounted for Flush Mounting
Type of Action: Type 1.B Action (for air gap)
Pollution Degree: 2
Rated Impulse Voltage: 2500 V
Construction of control: Independently Mounted for Flush Mounting
Type of Action: Type 1.B Action (for air gap)
Pollution Degree: 2
Rated Impulse Voltage: 2500 V
Construction of control: Independently Mounted for Flush Mounting
Type of Action: Type 1.B Action (for air gap)
Pollution Degree: 2
Rated Impulse Voltage: 2500 V
1/10hp(75W), motor
1/10hp(75W), motor 1/10hp(75W), motor
IC Radiation Exposure Statement:
This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
Déclaration d'exposition aux radiations:
Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement non contrôlé.
Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps.
Interruptor de
pared inteligente
para el control
de ventiladores
60226
ZWA4014
ADVERTENCIA: PELIGRO DE DESCARGA ELÉCTRICA
DESCONECTE la electricidad al circuito derivado para el dispositivo en el tablero de servicio. Todas las
conexiones de los cables deben hacerse con la electricidad DESCONECTADA para evitar lesiones
personales o daños al dispositivo. Este dispositivo esdiseñado para instalarse de acuerdo con el
National Electric Code y las reglamentaciones locales de Estados Unidos o el Canadian Electrical Code
y las reglamentaciones locales de Canadá. Si no está seguro o no se siente capacitado para realizar
esta instalación, consulte a un electricista calificado.
CABLEADO DE INTERRUPTOR INDIVIDUAL
CABLEADO DEL INTERRUPTOR DE TRES VÍAS
1. Conecte el cable verde o pelado al terminal TIERRA.
2. Conecte el cable negro de la luz al terminal de LÍNEA o al de CARGA.
3. Conecte el cable negro de la fuente de enera (energizado) al otro terminal deNEA o
de CARGA.
4. Conecte el cable blanco al terminal NEUTRO, de ser necesario, use un cable de puente.
NOTA: El terminal de viajero solo se usa para cableado de múltiples interruptores y no se
utiliza en un sistema de dos vías (un interruptor y una carga).
5. Fije el dispositivo a la caja del interruptor con los tornillos de montaje provistos;
aserese de que los cables no estén pellizcados ni aplastados.
6. Instale la placa de pared.
LADO DE LA LÍNEA (DISPOSITIVO Z-WAVE)
1. Desconecte la energía al circuito en el disyuntor o la caja de fusibles
2. Retire la placa de pared del lado de la línea
3. Retire el interruptor de la caja del interruptor de lado de la línea. NO
desconecte los cables
4. Etiquete el cable de la LÍNEA de fuente de enera
5. Etiquete el cable viajero restante 1: apunte el color de este cable para la
instalacn del interruptor de 3 vías
6. Etiquete el otro cable viajero 2 restante
7. Desconecte todos los cables del interruptor
8. Conecte el cable verde o pelado al terminal A TIERRA
9. Conecte el cable de línea al terminal de LÍNEA o al de CARGA
10. Conecte el cable viajero 1 al otro terminal deNEA o de CARGA
11. Conecte el cable viajero 2 al terminal de VIAJERO
12. Conecte un extremo de un cable de puente al haz de cables neutros usando
un conector de cables
13. Conecte el otro extremo del cable de puente al terminal NEUTRO
14. Fije el dispositivo a la caja del interruptor con los tornillos de montaje
provistos. Aserese de que los cables no estén pellizcados ni aplastados
15. Instale la placa de pared
LADO DE LA CARGA (INTERRUPTOR DE 3 VÍAS)
1. Retire la placa de pared del lado de la carga
2. Retire el interruptor de la caja del interruptor del lado de la carga. NO
desconecte los cables
3. Etiquete el cable de la CARGA de la luz
4. Etiquete el cable viajero 1: recuerde el color del cable de la instalación del
dispositivo Z-Wave
5. Etiquete el cable viajero 2
TRAVELER
LOAD/LINE
LOAD/LINE
NEUTRAL
GROUND
DD
C
C
B
B
A
A
LÍNEA
CARGA
TIERRA
NEUTRO
PUENTE
Esquema de cableado típico para una instalación de 3 vías
C
H H
LÍNEA
LÍNEA
VIAJERO 2
VIAJERO 1
TIERRA
VIAJERO 2
LÍNEA
VIAJERO 1
C
H H
Carga
Lado de la Línea (energizado) Lado de la carga
Escanee el código
para conocer un
proceso alternativo
de cableado de
3 vías
Dispositivo Z-Wave en el lado de la línea con interruptor de 3 vías estándar
6. Desconecte todos los cables del interruptor
7. Conecte el cable verde o pelado al terminal A TIERRA
8. Conecte el cable de carga al cable viajero 1 usando un conector de cables
9. Conecte el cable viajero 2 al terminal de laNEA (energizado)
10. Conecte un extremo de un cable de puente al haz de cables neutros usando un
conector de cables
11. Conecte el otro extremo del cable de puente al terminal COMÚN
12. Fije el interruptor de 3 vías a la caja del interruptor. Asegúrese de que los
cables no estén pellizcados ni aplastados
13. Instale la placa de pared
14. Aplique la energía en el disyuntor o la caja
de fusibles
REQUISITOS DE CABLEADO
Fije usando los orificios de la caja, pele 5/8 pulg. (16mm) del aislamiento.
UL especifica que el par de apriete para los tornillos es de 12lbf-pulg. (14Kgf-cm).
CICLO DE LUZ LED
The LED behind the fan control acts as a guide light or
status indicator.
Cómo recorrer el ciclo de opciones:
1. Presione el botón del menú durante cinco segundos
2. Presione arriba tres veces y abajo una vez,
rápidamente. La luz indicadora parpadeará de color
azul
3. Push the toggle up:
A. Una vez para encender la luz LED cuando la
carga está desactivada. Se ilumina de color
naranja para confirmar
B. Dos veces para encender la luz LED cuando la
carga está activada. Se ilumina de color amarillo
para conrmar
C. Tres veces para que esté siempre apagada. Se
ilumina de color rosa para conrmar
D. Cuatro veces para que es siempre encendida.
Se ilumina de color morado para confirmar
4. Presione el botón del menú una vez para guardar. La
luz indicadora parpadea dos veces de color verde
CAMBIAR EL COLOR DE LA LUZ INDICADORA
Se puede cambiar el color de la luz LED indicadora
desde el dispositivo.
1. Presione el botón del menú durante cinco segundos
2. Press toggle up once and down once once – LED
illuminates in selected color
3. Presione la paleta superior o inferior para recorrer las
opciones de color:
Rojo
Naranja
Amarillo
Verde
4. Presione el botón del menú una vez para guardar. La
luz indicadora parpadea dos veces de color verde
Inserte los cables en los orificios y NO enrosque los cables en los tornillos
NO retire los tornillos
¡IMPORTANTE! El dispositivo Z-Wave opera con interruptores auxiliares de manera predeterminada. Para instalarlo con un interruptor de 3 vías esndar, siga los pasos en configuración de 3 vías. Las siguientes instrucciones son para el cableado de un
interruptor de 3 vías estándar. Consulte el manual del interruptor auxiliar para ver mo instalar interruptores auxiliares.
¡Gracias por su compra!
Instrucciones
ciles
Lea las instrucciones
o mire el video con el
paso a paso.
Registre su
producto
Reciba ofertas
exclusivas y registre
su producto.
Para ver más productos Enbrighten, visite
nuestro sitio web: byjasco.com.
¿Le gusta nuestro producto?
Deje una resa en el sitio web de
su comercio favorito o en
amazon.com.
¿Tiene algún problema?
Díganos cómo podemos ayudar.
Llame al 1-800-654-8483, de lunes
central.
Escanee el código o visite
yjasco.com/60226i.
Escanee el código o visite
byjasco.com/deals.
TRAVELER
LOAD/LINE
LOAD/LINE
NEUTRAL
GROUND
Carga
C
H H
A. NEA: cable negro/tornillo negro
B. VIAJERO 1: cable negro/tornillo negro (salida)
C. VIAJERO 2: cable rojo/tornillo de bronce (viajero)
D. TIERRA: cable verde o pelado/tornillo verde
E. PUENTE: cable blanco/tornillo plateado
D
D
EE
C
C
C
B
B
A
A
B
B
A
D
C
VIAJERO 2
VIAJERO 2
LÍNEA
VIAJERO 1
VIAJERO 1
NEUTRO
TIERRA
TIERRA
PUENTE
LÍNEA
LINE
Escanee el código QR abajo si no
hay un haz de cables de línea en
la caja del interruptor
Azul (predeterminado)
Rosa
Morado
Blanco
Montage mural
intelligent
commande
de ventilateur
60226
ZWA4014
COUPEZ lalimentation dans le circuit de dérivation relatif à l’appareil sur le panneau de branchement. Tous
d’endommager l’appareil. Ce dispositif est prévu pour une installation conforme au Code national de
l’électricité et aux règlements locaux des États-Unis ou au Code canadien de lélectricité et aux règlements
sentez pas à laise de laccomplir, veuillez consulter un électricien qualifié.
CÂBLAGE AVEC UN SEUL INTERRUPTEUR
CÂBLAGE D’INTERRUPTEUR À TROIS VOIES
1. Reliez le l vert/nu à la borne de MISE À LA TERRE.
2. Raccordez le l noir de lappareil déclairage à la borne SECTEUR/CHARGE.
3. Raccordez le l noir de la source dalimentation (sous tension) à lautre borne
SECTEUR/CHARGE.
4. Raccordez lel blanc à la borne NEUTRE utilisez un cavalier au besoin.
La borne pendentif est seulement utilisée pour le câblage à plusieurs
interrupteurs et non dans un système à deux voies (un interrupteur et une charge).
5. Fixez lappareil dans la boîte de jonction avec les vis de montage fournies en veillant à ce
que les ls ne soient pas pincés ni écrasés.
6. Installez la plaque murale.
CÔTÉ SECTEUR (APPAREIL Z-WAVE)
1. Coupez lalimentation au disjoncteur ou à la bte à fusibles.
2. Retirez la plaque murale côté secteur.
3. Retirez linterrupteur du côté secteur de la bte de jonction – NE débranchez
PAS les fils.
4. Étiquetez le l du té de la source dalimentation SECTEUR.
5. Étiquetez lel restant pendentif 1 – notez la couleur de ce fil pour linstallation
de l’interrupteur à trois voies.
6. Étiquetez lautre l restant pendentif 2.
7. Débranchez tous les fils de linterrupteur.
8. Reliez lel vert/nu à la borne de MISE À LA TERRE.
9. Raccordez le fil secteur soit à la borne SECTEUR ou CHARGE.
10. Raccordez lel pendentif 1 à lautre borne SECTEUR ou CHARGE.
11. Raccordez le l pendentif 2 à la borne PENDENTIF.
12. Reliez une extmité d’un cavalier au faisceau de ls neutre à laide d’un
capuchon de connexion.
13. Reliez lautre extrémité du cavalier à la borne NEUTRE.
14. Fixez lappareil à la boîte de jonction avec les vis de montage fournies
veillez à ce que les ls ne soient pas pincés ni écrasés.
15. Installez la plaque murale.
CÔTÉ CHARGE (INTERRUPTEUR À TROIS VOIES)
1. Retirez la plaque murale charge.
2. Retirez l’interrupteur du côté charge de la boîte de jonctionNE débranchez
PAS les ls.
3. Étiquetez lel du côté de l’appareil déclairage CHARGE.
4. Étiquetez le fil pendentif 1 voyez la couleur du fil de l’installation de lappareil
Z-Wave
5. Étiquetez le l pendentif 2.
TRAVELER
LOAD/LINE
LOAD/LINE
NEUTRAL
GROUND
DD
C
C
B
B
A
A
SECTEUR
CHARGE
MISE À LA
TERRE
NEUTRE
CAVALIER
Schéma de câblage classique pour une installation à trois voies
Côté secteur (sous tension) Côté charge
C
H H
SECTEUR
MISE À LA
TERRE
SECTEUR
C
H H
Charge
PENDENTIF 1
SECTEUR
Balayez le code
pour voir un
autre processus
de câblage
à trois voies
Appareil Z-Wave côté secteur avec interrupteur à trois voies
6. Débranchez tous les ls de linterrupteur.
7. Reliez le l vert/nu à la borne de MISE À LA TERRE.
8. Reliez le fil de charge au fil pendentif 1 à laide d’un capuchon de connexion.
9. Reliez le l pendentif 2 à la borne SECTEUR (sous tension).
10. Reliez une extmité d’un cavalier au faisceau de ls neutre à laide d’un
capuchon de connexion.
11. Reliez l’autre extrémité du cavalier à la borne COMMUNE.
12. Fixez linterrupteur à trois voies dans la boîte de jonction en veillant à ce que
les ls ne soient pas pins ni écrasés.
13. Installez la plaque murale.
14. Allumez lalimentation de la boîte à fusibles
ou du coupe-circuit.
EXIGENCES CONCERNANT LE CÂBLAGE
UL précise que le couple de serrage des vis est de 14Kgf/cm (12lbf/po).
DEL DE CYCLE
The LED behind the fan control acts as a guide light or
status indicator.
Passer dune option à lautre :
1. Appuyez sur le bouton du menu pendant cinq secondes
2. Appuyez trois fois sur la partie supérieure et rapidement
sur la partie inférieure une fois le voyant bleu clignote
3. Push the toggle up:
A. Une fois pour que la DEL soit allumée lorsque la
charge est désactivée le voyant orange sallume
pour confirmer la sélection
B. Deux fois pour que la DEL soit allumée lorsque la
charge est actie le voyant jaune sallume pour
confirmer la sélection
C. Trois fois pour que le voyant soit toujours éteint le
voyant rose sallume pour confirmer la sélection
D. Quatre fois pour que le voyant soit toujours allumé
le voyant violet sallume pour confirmer la
lection
4. Appuyez une fois sur le bouton du menu pour
enregistrer la sélection le voyant vert clignote deux fois
CHANGER LA COULEUR DU VOYANT À DEL
On peut changer la couleur du voyant à DEL à partir de
lappareil.
1. Appuyez sur le bouton du menu pendant cinq secondes
2. Press toggle up once and down once once LED
illuminates in selected color
3. Appuyez sur la palette supérieure ou inférieure pour
passer d’une option de couleur à lautre :
Rouge
Orange
Jaune
Vert
4. Appuyez une fois sur le bouton du menu pour
enregistrer la sélection le voyant vert clignote deux fois
Insérez les fils dans les trous; NE PAS enrouler les fils autour des vis
NE PAS retirer les vis
IMPORTANT! L’appareil Z-Wave fonctionne avec des interrupteurs supplémentaires parfaut. Pour linstaller avec un interrupteur à trois voies standard, suivez les étapes présentées sous la configuration à trois voies. Les instructions ci-après sont pour le
câblage dun interrupteur à trois voies standard. Consultez le manuel de l’interrupteur supplémentaire pour installer les interrupteurs supplémentaires.
Merci de votre achat!
Instructions
simplifiées
Lisez les instructions
ou regardez la vidéo
facile à comprendre.
Enregistrer
votre produit
R
exclusives et enregistrez
votre produit.
Pour voir d’autres produits Enbrighten,
visitez notre site Web www.Jasco .com.
Balayez le code ou visitez
yjasco.com/60226i.
Balayez le code ou visitez
byjasco.com/deals.
Notre produit vous plaît?
Laissez-nous un avis sur le site de
votre détaillant préféré ou sur
amazon.com.
Vous éprouvez des problèmes?
Dites-nous ce que nous pouvons faire
pour vous aider.
Appelez au 1-800-654-8483
A. SECTEUR Fil noir/vis noire (entrée)
B. CHARGE Fil noir/vis noire (sortie)
C. MISE À LA TERRE Fil vert ou nu/vis verte
D. CAVALIER Fil blanc/vis argentée
TRAVELER
LOAD/LINE
LOAD/LINE
NEUTRAL
GROUND
Charge
C
H H
A. SECTEUR Fil noir/vis noire
B.
C.
D. MISE À LA TERRE Fil vert ou nu/vis verte
E. CAVALIER Fil blanc/vis argentée
D
D
EE
C
C
C
B
B
A
A
B
B
A
D
C
PENDENTIF 2
PENDENTIF 2
SECTEUR
SECTEUR
PENDENTIF 1
PENDENTIF 1
NEUTRE
MISE À LA
TERRE
MISE À LA
TERRE
CAVALIER
SECTEUR
Balayez le code QR ci-dessous s’il
n’y a pas de faisceau secteur dans
la boîte de jonction
Bleu (parfaut)
Rose
Violet
Blanc
A. NEA: cable negro/tornillo negro (entrada)
B. CARGA: cable negro/tornillo negro (salida)
C. TIERRA: cable verde o pelado/tornillo verde
D. PUENTE: cable blanco/tornillo plateado
RETIRE EL INTERRUPTOR UNIPOLAR
1. Desconecte la
energía al circuito
en el disyuntor o
la caja de fusibles.
¡IMPORTANTE!
Verifique que la
alimentación a la
caja del interruptor
esté en OFF
(APAGADO) antes
de continuar.
2. Retire la placa de
pared.
3. Retire los tornillos
de montaje del
interruptor.
4. Retire con
cuidado el
interruptor de la
caja del
interruptor. NO
desconecte los cables.
5. Identifique los siguientes cables en la caja del interruptor:
A. Tierra: verde/pelado
B. Línea (energizado): negro (conectado a la alimentación)
C. Carga: negro (conectado a la iluminación)
D. Neutro: blanco
6. Desconecte los cables del interruptor existente. Etiquete los cables de acuerdo
con las conexiones de los terminales anteriores.
Hacia la luz (carga)
Desde la caja del
disyuntor
LÍNEA
CARGA
TIERRA
NEUTRO
C
B
D
A
Interruptor antiguo
RETIRER L’INTERRUPTEUR UNIPOLAIRE
1. Éteignez
l’alimentation
du circuit au
disjoncteur ou à
la bte à fusibles.
IMPORTANT! Avant
de poursuivre,
assurez- vous que
l’alimentation est
COUPÉE à la boîte
de jonction.
2. Retirez la plaque
murale.
3. Retirez les vis de
montage de
l’interrupteur.
4. Retirez
doucement
l’interrupteur de
la bte de jonction – NE PAS débrancher les fils.
5.
A.
B. Secteur (sous tension) – Fil noir (relié à lalimentation)
C. Charge – Fil noir (relié au luminaire)
D. Neutre – Blanc
6. branchez les ls de l’interrupteur existant – étiquetez les fils conformément
aux précédents raccords terminaux.
Ancien interrupteur
C
B
D
A
CHARGE
SECTEUR
MISE À LA
TERRE
NEUTRE
Sortie à l’appareil
d’éclairage (charge)
De la boîte des
disjoncteurs
Z-W AVE DSK
PIN: XXXXX
DSK :
XXXX X
-25651-2267 1
-26939-4759 9
-19612-2587 2
-47752
Z-W AVE DSK
PIN: XXXXX
DSK :
XXXX X
-25651-2267 1
-26939-4759 9
-19612-2587 2
-47752
AGREGAR SU DISPOSITIVO A UNA RED Z-WAVE
1. Siga las instrucciones correspondientes a su controlador Z-Wave certificado
para agregar un dispositivo a la red Z-Wave.
2. Una vez que el controlador esté listo para agregar su dispositivo, presione la
parte superior o inferior del interruptor basculante.
Tiene control total para encender o apagar su aparato de iluminación de acuerdo
con grupos, escenas, horarios y automatizaciones interactivas programadas por
su controlador.
Si su controlador Z-Wave certificado cuenta con acceso remoto, puede controlar
el aparato desde sus dispositivos móviles.
Si el controlador le pide ingresar el código de seguridad S2, consulte el código
QR/mero de seguridad en el costado de la caja o la etiqueta del digo QR en
el producto (ver Figura 1). Ingrese el código de 5 dígitos.
Figura 1:
PARA RETIRAR Y RESTABLECER EL DISPOSITIVO
1. Siga las instrucciones correspondientes a su controlador Z-Wave certificado
para retirar un dispositivo de la red Z-Wave.
2. Una vez que el controlador esté listo para extraer su dispositivo, presione la
palanca hacia arriba o hacia abajo.
PARA VOLVER A CONFIGURAR SU INTERRUPTOR SEGÚN LOS AJUSTES DE
FÁBRICA
1. Deslice el interruptor del espacio de aire hacia la derecha.
2. Mientras presiona el botón de apagado (inferior), empuje el espacio de aire
hacia la izquierda y continúe presionando el botón de apagado. La luz LED
parpadea mientras se recorren una vez los ocho colores.
NOTA: Este procedimiento solo se debe utilizar en ausencia del controlador
principal de su red o si el controlador no funciona.
NOTA: Los productos habilitados para SmartStart se pueden agregar a una red
Z-Wave escaneando el código QR que se encuentra en el producto con un
controlador que ofrezca inclusión de SmartStart. No se requieren acciones
adicionales y el producto SmartStart se agregará automáticamente dentro de 10
minutos de encenderlo en la proximidad de la red.
AJOUTER VOTRE APPAREIL À UN RÉSEAU Z-WAVE
1. Suivez les instructions relatives à votre contleur certifié Z-Wave pour ajouter
un appareil au réseau Z-Wave.
2. Une fois que le contrôleur est prêt à ajouter votre appareil, poussez sur la
partie supérieure ou inférieure de l’interrupteur basculant.
Vous avez le contrôle absolu sur la mise en marche et larrêt de votre appareil en
fonction des groupes, des scènes, des horaires et des automatisations interactives
programmés par votre contrôleur.
Si votre contrôleur certifié Z-Wave a une fonction d’accès à distance, vous pouvez
contrôler votre appareil à laide de vos appareils mobiles.
Si le contrôleur vous invite à entrer le code de sécurité S2, reportez-vous au code
QR/numéro de sécurité situé sur le côté de la boîte ou à létiquette de code QR
Figure 1:
RETIRER OU RÉINITIALISER LAPPAREIL
1. Pour retirer un appareil du réseau Z-Wave, suivez les instructions relatives à
votre contrôleur certifié Z-Wave.
2. Une fois que le contrôleur est prêt à retirer votre appareil, faites basculer
l'interrupteur vers le haut ou vers le bas.
TABLIR LES CONFIGURATIONS D’USINE DE VOTRE INTERRUPTEUR
1. Glissez l’interrupteur à entrefer vers la droite.
2. Pendant que vous appuyez sur le bouton « OFF » (bouton inférieur), tirez sur
l’interrupteur à entrefer vers la gauche et continuez dappuyer sur le bouton
« OFF ». Le voyant à DEL clignote et passe par les huit couleurs.
REMARQUE : Cette mesure ne doit être prise que si le contrôleur principal du
réseau est manquant ou autrement inutilisable.
REMARQUE : Les produits dotés de la fonction SmartStart peuvent être ajoutés à
produit au moyen d’un contrôleur permettant de lajouter à laide de la fonction
SmartStart. Aucune mesure ne doit être prise. Le produit SmartStart sera
automatiquement ajouté dans les 10 minutes qui suivent sa mise sous tension à
proximité du réseau.
  • Page 1 1
  • Page 2 2

Enbrighten 60226 Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues