Briggs & Stratton 01532-2 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur

Ce manuel convient également à

Owner’s Manual
Manuel de l'utilisateur
Manual del Propietario
Model 01532-2
Manual No. 192115GS
Revision 0 (01/07/2003)
Questions? Help is just a moment away!
Vous avez des questions? Vous n'avez pas besoin d'aller loin pour trouver de l'aide!
Preguntas? La ayuda es justa un momento lejos!
Call: Generator Helpline - 1-800-743-4115 M-F 8-5 CT
Appelez: Ligne d'assistance de Générateur - 1-800-743-4115 M-F 8-5 CT
Llamada: Generador Helpline - 1-800-743-4115 M-F 8-5 CT
1000
Starting
Watts
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
JEFFERSON, WISCONSIN, U.S.A.
900W Generator
2
TABLE OF CONTENTS
Safety Rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Know Your Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-10
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-13
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-14
Notes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Schematic/Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . 17
Replacement Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . 18-25
Emmision Control Warranty . . . . . . . . . . . . . . . . . . . . . 26
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
EQUIPMENT
DESCRIPTION
Read this manual carefully and become familiar
with your generator. Know its applications, its
limitations and any hazards involved.
The generators are an engine–driven, revolving field,
alternating current (AC) generator. It was designed to supply
electrical power for operating compatible electrical lighting,
appliances, tools and motor loads. The generator’s revolving
field is driven at about 3,600 rpm by a single-cylinder engine.
CAUTION! DO NOT exceed the generator’s
wattage/amperage capacity. See “Don’t Overload the
Generator” on page 10.
Every effort has been made to ensure that information in this
manual is accurate and current. However, we reserve the
right to change, alter or otherwise improve the product and
this document at any time without prior notice.
The Emission Control System for this generator is warranted
for standards set by the Environmental Protection Agency.
SAFETY RULES
This is the safety alert symbol. It is used to
alert you to potential personal injury
hazards. Obey all safety messages that follow
this symbol to avoid possible injury or death.
The safety alert symbol ( ) is used with a signal word
(DANGER, CAUTION, WARNING), a pictorial and/or a
safety message to alert you to hazards. DANGER
indicates a hazard which, if not avoided, will result in death
or serious injury. WARNING indicates a hazard which, if
not avoided, could result in death or serious injury.
CAUTION indicates a hazard which, if not avoided, might
result in minor or moderate injury. CAUTION, when
used without the alert symbol, indicates a situation that
could result in equipment damage. Follow safety messages
to avoid or reduce the risk of injury or death.
The engine exhaust from this product contains
chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
WARNING
In the State of California a spark arrester is required by law
(Section 4442 of the California Public Resources Code).
Other states may have similar laws. Federal laws apply on
federal lands. If you equip the muffler with a spark arrester,
it must be maintained in effective working order.
900W Generator
3
DO NOT allow any open flame, spark, heat, or lit cigarette
during and for several minutes after charging a battery.
Wear protective goggles, rubber apron, and rubber gloves.
Storage batteries give off explosive hydrogen gas
during recharging.
Hydrogen gas stays around battery for a long
time after battery has been charged.
Slightest spark will ignite hydrogen and cause
explosion.
You can be blinded or severely injured.
Battery electrolyte fluid contains acid and is
extremely caustic.
Contact with battery fluid will cause severe
chemical burns.
DANGER
WHEN ADDING FUEL
Turn generator OFF and let it cool at least 2 minutes before
removing gas cap. Loosen cap slowly to relieve pressure in tank.
Fill fuel tank outdoors.
DO NOT overfill tank. Allow space for fuel expansion.
Keep fuel away from sparks, open flames, pilot lights, heat, and
other ignition sources.
DO NOT light a cigarette or smoke.
WHEN OPERATING EQUIPMENT
DO NOT tip engine or equipment at angle which causes fuel
to spill.
This generator is not for use in mobile equipment or marine
applications.
WHEN TRANSPORTING OR REPAIRING EQUIPMENT
Transport/repair with fuel tank EMPTY or with fuel shutoff
valve OFF.
Disconnect spark plug wire.
WHEN STORING FUEL OR EQUIPMENT WITH FUEL
IN TANK
Store away from furnaces, stoves, water heaters, clothes
dryers or other appliances that have pilot light or other
ignition source because they can ignite fuel vapors.
Fuel and its vapors are extremely flammable and
explosive.
Fire or explosion can cause severe burns or
death.
WARNING
This generator does not meet U. S. Coast Guard Regulation
33CFR-183 and should not be used on marine applications.
Failure to use the appropriate U. S. Coast Guard approved
generator could result in bodily injury and/or property damage.
WARNING
Operate generator ONLY outdoors.
Keep at least 2 feet of clearance on all sides of generator for
adequate ventilation.
DO NOT operate generator inside any building or enclosure,
including the generator compartment of a recreational vehicle (RV).
Running generator gives off carbon monoxide,
an odorless, colorless, poison gas.
Breathing carbon monoxide will cause nausea,
fainting or death.
DANGER
National Electric Code requires generator to be properly
grounded to an approved earth ground. Call an electrician for
local grounding requirements.
Failure to properly ground generator can result
in electrocution, especially if the generator is
equipped with a wheel kit.
DANGER
When using generator for backup power, notify utility
company. Use approved transfer equipment to isolate
generator from electric utility.
Use a ground circuit fault interrupter (GFCI) in any damp or
highly conductive area, such as metal decking or steel work.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords which are worn,
frayed, bare or otherwise damaged.
DO NOT operate generator in the rain.
DO NOT handle generator or electrical cords while standing
in water, while barefoot, or while hands or feet are wet.
DO NOT allow unqualified persons or children to operate or
service generator.
Generator produces powerful voltage.
Failure to isolate generator from power utility
can result in death or injury to electric utility
workers due to backfeed of electrical energy.
DANGER
900W Generator
4
DO NOT touch hot surfaces.
Allow equipment to cool before touching.
Running engines produce heat. Temperature of
muffler and nearby areas can reach or exceed
150°F (65°C).
Severe burns can occur on contact.
WARNING
DO NOT tamper with governed speed. Generator supplies
correct rated frequency and voltage when running at governed
speed.
DO NOT modify generator in any way.
Excessively high operating speeds increase risk of injury
and damage to generator.
Excessively low speeds impose a heavy load.
CAUTION
See “Don’t Overload Your Generator” on page 10.
Start generator and let engine stabilize before connecting
electrical loads.
Connect electrical loads in OFF position, then turn ON for
operation.
Turn electrical loads OFF and disconnect from generator
before stopping generator.
Exceeding generators wattage/amperage capacity can
damage generator and/or electrical devices connected
to it.
CAUTION
Use generator only for intended uses.
If you have questions about intended use, ask dealer or
contact your nearest authorized service center.
Operate generator only on level surfaces.
DO NOT expose generator to excessive moisture, dust, dirt,
or corrosive vapors.
DO NOT insert any objects through cooling slots.
If connected devices overheat, turn them off and disconnect
them from generator.
Shut off generator if:
-electrical output is lost;
-equipment sparks, smokes, or emits flames;
-unit vibrates excessively.
Improper treatment of generator can damage it and
shorten its life.
CAUTION
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR
GENERATOR
Disconnect the spark plug wire from the spark plug and place
the wire where it cannot contact spark plug.
Unintentional sparking can result in fire or
electric shock.
WARNING
900W Generator
5
12 Volt DC, 8.3 Amp Accessory Jack — May be used
to power 12 Volt DC electrical devices or recharge 12 Volt
DC batteries.
120 Volt AC, 7.5 Amp Receptacles — May be used to
supply electrical power for the operation of 120 Volt AC,
single phase, 60 Hz electrical lighting, appliance, tool and
motor loads.
Air Cleaner — Uses a foam element to limit the amount
of dirt and dust that enters the engine.
Choke Lever — Used to manually provide proper starting
mixture when engine is cold.
Circuit Breaker (AC) — Receptacles are provided with a
push-to-reset circuit breaker to protect the generator
against electrical overload.
Data Tag — Provides model, revision and serial number
of generator. Please have these readily available if calling for
assistance.
Engine ON/OFF Switch — Used to stop a running
engine.
Fuel Shut-Off Valve — Use this valve to turn the fuel
supply on and off.
Fuel Tank — Capacity of 1.2 U.S. gallons (4.5 liters) of
fuel.
Grounding Lug — Use this connection to properly
ground the generator. See ”Grounding the Generator” on
page 7.
Oil Fill/Drain — Access to oil fill dipstick and engine oil
drain plug.
Recoil Starter — Used for starting the engine.
Spark Plug — Access to engine spark plug.
KNOW YOUR GENERATOR
Read this owner’s manual and safety rules before operating your generator.
Compare the illustrations with your generator to familiarize yourself with the locations of various controls and
adjustments. Save this manual for future reference.
120 Volt AC, 7.5 Amp
Receptacle
Recoil Starter
Circuit Breaker (AC)
Oil Fill/Drain
(inside cover)
Choke Lever
Spark Plug (inside
cover)
Fuel Tank
Air Cleaner
Grounding Lug
12 Volt DC, 8.3 Amp
Accessory Jack
Engine ON/OFF Switch
Fuel Shut-Off Valve
Data Tag
900W Generator
6
ASSEMBLY
Carton Contents
Check all contents. If any parts are missing or damaged, call
the generator helpline at 1-800-743-4115. If calling for
assistance, please have the model, revision, and serial number
from the data tag available. Shipped with your generator is:
Main unit
Oil bottle
Owner’s manual
Battery charge cables
BEFORE STARTING ENGINE
Add Oil
NOTE: When adding oil to the engine crankcase in the
future, use only high quality detergent oil rated with API
service classification SG, SF/CC, CD. Select the oil’s viscosity
grade according to your expected operating temperature:
SAE 10W-30 is recommended for general all temperature
use. Multi-viscosity oils (10W30, etc.) improve starting in
cold weather, but these oils will result in increased oil
consumption. Check your engine oil level more frequently
to avoid possible damage from running low on oil.
To Add Engine Oil:
Place the generator on a level surface.
Remove the oil fill cover.
Remove oil filler cap and wipe dipstick clean (Figure 1).
If the oil level is not at the point of overflowing from the
oil filler neck, slowly fill engine with recommended oil.
Reinstall oil filler cap and tighten securely.
Replace the oil fill cover.
Check the engine oil level before starting each time
thereafter.
Add Fuel
WARNING! NEVER fill fuel tank indoors. NEVER
fill fuel tank when engine is running or hot. Allow unit
to cool for two minutes before refueling. DO NOT
light a cigarette or smoke when filling the fuel tank.
WARNING! DO NOT overfill the fuel tank.
Always allow room for fuel expansion.
Use clean fresh UNLEADED fuel with a pump rating of
86 or higher. DO NOT use premium or leaded fuel. DO
NOT mix oil with fuel.
Clean area around fuel fill cap, remove cap.
Check the fuel level.
If fuel level is low, slowly add recommended fuel to fuel
tank, up to the shoulder of the fuel strainer (Figure 2).
Be careful not to overfill (there should be no fuel in the
filler neck).
NOTE: Occasionally clear the fuel strainer of any dirt,
rust, or other particulate matter.
Install fuel cap and wipe up any spilled fuel.
Occasionally you may hear a light “spark knock” or
“pinging” (metallic rapping noise) while operating under
heavy loads. This is no cause for concern. If spark knock or
pinging occurs at a steady engine speed under normal load,
change brands of fuel or obtain a higher octane rated fuel.
If pinging or spark knock persists, see your local Briggs &
Stratton repair center.
colder 32°F warmer
SAE 10W30 SAE 30
Oil Filler Neck
Figure 1 — Adding Engine Oil
Fill to This Level
Figure 2 — Fuel Level
900W Generator
7
GROUNDING THE
GENERATOR
The National Electrical Code requires that the frame and
external electrically conductive parts of this generator be
properly connected to an approved earth ground. Local
electrical codes may also require proper grounding of the
unit. For that purpose, a GROUNDING WING NUT is
provided on the generator housing (Figure 3).
Generally, connecting a No. 12 AWG (American Wire
Gauge) stranded copper wire to the grounding wing nut
and to an earth-driven copper or brass grounding rod
(electrode) provides adequate protection against electrical
shock. Be careful to keep the grounding wire attached after
connecting the stranded copper wire. However, local codes
may vary widely. Consult with a local electrician for
grounding requirements in your area.
Properly grounding the generator helps prevent electrical
shock if a ground fault condition exists in the generator or
in connected electrical devices. Proper grounding also helps
dissipate static electricity, which often builds up in
ungrounded devices.
OPERATING THE
GENERATOR
CAUTION! NEVER start or stop the engine with
electrical loads connected to the unit and with the
connected devices turned ON.
Starting the Engine
Disconnect all electrical loads from the generator. Use the
following start instructions:
Be sure the spark plug wire is attached to the spark plug.
Turn the fuel valve to the “Open” position (fully
clockwise) (Figure 4).
Slide the choke lever to the “Choke” position (all the
way to the right) (Figure 5).
Place the engine switch in the “On” position (Figure 6).
Grasp starter grip and slowly pull the rope until you feel
some resistance, then pull the cord out with a rapid full
arm stroke. Let rope return slowly. DO NOT let rope
“snap back” against the unit.
Figure 5 — Choke Lever
Figure 4 — Fuel Valve in Open Position
Figure 6 — Engine Switch in On Position
Figure 3 — Grounding Wing Nut
Grounding Wing Nut
900W Generator
8
NOTE: If engine starts after 3 pulls, but fails to run for
more than 10 seconds, check for proper oil level in
crankcase. This unit is equipped with a Oil Alert System
(see page 8).
Slide the choke lever left to the “Run” position as the
engine warms up.
NOTE: Under no load conditions, the engine speed may
vary slightly faster or slower until engine temperatures
stabilize.
CAUTION! Breathing Hazard! NEVER run
engine in enclosed poorly ventilated areas. Engine
exhaust contains carbon monoxide, an odorless and
deadly gas.
Connecting Electrical Loads
Let engine stabilize and warm up for a few minutes after
starting.
DO NOT connect 240 Volt loads to 120 Volt receptacles.
DO NOT connect 3–phase loads to the generator.
DO NOT connect 50 Hz loads to the generator.
Plug in and turn on the desired 120 Volt AC, single
phase, 60 Hertz electrical loads.
DO NOT OVERLOAD THE GENERATOR. Add up
the rated watts (or amps) of all loads to be connected at
one time. This total should not be greater than the rated
wattage/amperage capacity of the generator. See “Don’t
Overload the Generator” on page 10.
Stopping the Engine
Unplug all electrical loads from the unit. NEVER start or
stop engine with electrical devices plugged in and turned
on.
Let engine run at no–load for two minutes to stabilize
the internal temperatures.
Move engine switch to the “Off” position.
Turn the fuel valve to the “Close” position (fully
counterclockwise).
NOTE: In an emergency, stop the engine by moving the
engine switch to the “Off” position.
Oil Alert System
The Oil Alert System is designed to prevent engine damage
caused by an insufficient amount of oil in the crankcase.
Before the oil level in the crankcase can fall below a safe
limit, the Oil Alert System will automatically shut down the
engine (the engine switch will remain in the “On” position).
If the Oil Alert System shuts down the engine, add engine
oil.
Charging a Battery
WARNING! Storage batteries emit explosive gas
while charging that remains around a battery for a
long time after it has been charged. The slightest
spark can ignite the gas, causing an explosion that
can shatter the battery and cause blindness or
other injury.
WARNING! DO NOT permit smoking, open
flame, sparks or any other source of heat around a
battery. DO NOT use a lighter or other flame for
checking battery fluid levels. Wear protective
goggles, rubber apron and rubber gloves when
working around a battery. Battery electrolyte fluid is
an extremely caustic sulfuric acid solution that can
cause severe burns. DO NOT permit fluid contact
with eyes, skin, clothing, etc. If spill occurs, flush
area with clear water immediately.
Your generator has the capability of recharging a discharged
12 Volt automotive or utility style storage battery. DO
NOT use the unit to charge any 6 Volt batteries. DO NOT
use the unit to crank an engine having a discharged battery.
To recharge 12 Volt batteries, proceed as follows:
If necessary, clean battery posts or terminals.
Check fluid level in all battery cells. If necessary, add
ONLY distilled water to cover separators in battery
cells. DO NOT use tap water.
If the battery is equipped with vent caps, make sure they
are installed and are tight.
Connect battery charge cable connector plug to the
12 Volt DC panel receptacle.
Connect battery charge cable clamp with red handle to
battery post or terminal indicated by Positive, POS or
(+) (Figure 7).
900W Generator
9
Connect battery charge cable clamp with black handle
to battery post or terminal indicated by Negative,
NEG, or () (Figure 7).
Start generator. Let the engine run while battery
recharges.
When battery has charged, shut down engine (see
“Stopping The Engine”)
NOTE: Use an automotive hydrometer to test battery
state of charge and condition. Follow the hydrometer
manufacturer’s instructions carefully. Generally, a battery is
considered to be at 100% state of charge when specific
gravity of its fluid (as measured by hydrometer) is 1.260 or
higher.
CONNECTOR PLUGS
120 Volt AC, 15 Amp Receptacle
Each outlet socket is protected against overload by a
7.5 Amp push-to-reset circuit breaker. Use each receptacle
to operate 120 Volt AC, single phase, 60 Hz electrical loads
requiring up to 1,000 watts (1.0 kW) of power (Figure 8).
CAUTION! Although each receptacle is rated
for 120 Volts at 15 Amps (1,440 watts or 1.44 kW),
the generator is rated for a total of 1,000 watts.
Powering loads that exceed the wattage capacity of
the generator can damage it or cause serious
injuries. The total of loads powered through these
receptacles should not exceed 7.5 Amps.
12 Volt DC Accessory Jack
This receptacle allows you to recharge a 12 Volt
automotive or utility style storage battery with the battery
charge cable provided. Camping-style air pumps, lanterns,
fans, or other 12 Volt devices having a cigarette lighter-type
plug may also be powered by this outlet (Figure 9).
This receptacle can not recharge 6 Volt batteries and can
not be used to crank an engine having a discharged battery.
See “Charging a Battery” (page 8) before attempting to
recharge a battery.
EXTENSION CORDS
Use only high quality, well-insulated, extension cords with
the generator’s 120 Volt electrical receptacles.
Check the ratings of all extension cords before you use
them. Such cords should be rated for 125 Volt AC loads at
15 Amps (or greater) for most electrical devices. Some
devices, however, may not require this type of extension
cord. Check the owner’s manuals of those devices for their
recommendations.
Keep extension cords as short as possible, preferably less
than 15 feet long, to prevent voltage drop and possible
overheating of wires.
Figure 8 — 120 Volt AC, 15 Amp Duplex Receptacle
Figure 9 — 12 Volt DC Accessory Jack
Red Lead
To 12 Volt DC Panel
Receptacle
Positive
Negative
Figure 7 — Battery Connections
900W Generator
10
DON'T OVERLOAD YOUR
GENERATOR
Capacity
You must make sure your generator can supply enough
rated (running) and surge (starting) watts for the items you
will power at the same time. Follow these simple steps:
1. Select the items you will power at the same time.
2. Total the rated (running) watts of these items. This is
the amount of power your generator must produce to
keep your items running. See Figure 10.
3. Estimate how many surge (starting) watts you will
need. Surge wattage is the short burst of power
needed to start electric motor-driven tools or
appliances such as a circular saw or refrigerator.
Because not all motors start at the same time, total
surge watts can be estimated by adding only the
item(s) with the highest additional surge watts to the
total rated watts from step 2.
Example:
Total Rated (Running) Watts = 3075
Highest Additional Surge Watts = 1800
Total Generator Output Required = 4875
Power Management
To prolong the life of your generator and attached devices,
it is important to take care when adding electrical loads to
your generator. There should be nothing connected to the
generator outlets before starting it's engine. The correct
and safe way to manage generator power is to sequentially
add loads as follows:
1. With nothing connected to the generator, start the
engine as described in this manual.
2. Plug in and turn on the first load, preferably the largest
load you have.
3. Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly.
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
NEVER add more loads than the generator capacity. Take
special care to consider surge loads in generator capacity,
as described above.
*Wattages listed are approximate only. Check tool or
appliance for actual wattage.
Tool or Appliance
Rated (Running)
Watts
Additional Surge
(Starting) Watts
Window Air
Conditioner
1200 1800
Refrigerator 800 1600
Deep Freezer 500 500
Television 500 -
Light (75 Watts) 75 -
3075 Total
Running Watts
1800 Highest
Surge Watts
Tool or Appliance
Rated*
(Running)
Watts
Additional
Surge
(Starting)
Watts
Essentials
Light Bulb - 75 watt
75
-
Deep Freezer
500
500
Sump Pump
800
1200
Refrigerator/Freezer - 18 Cu. Ft.
800
1600
Water Well Pump - 1/3 HP
1000
2000
Heating/Cooling
Window AC - 10,000 BTU
1200
1800
Window Fan
300
600
Furnace Fan Blower - 1/2 HP
800
1300
Kitchen
Microwave Oven - 1000 Watt
1000
-
Coffee Maker
1500
-
Electric Stove - Single Element
1500
-
Hot Plate
2500
-
Family Room
DVD/CD Player
100
-
VCR
100
-
Stereo Receiver
450
-
Color Television - 27”
500
-
Personal Computer w/17” monitor
800
-
Other
Security System
180
-
AM/FM Clock Radio
300
-
Garage Door Opener - 1/2 HP
480
520
Electric Water Heater - 40 Gallon
4000
-
DIY/Job Site
Quartz Halogen Work Light
1000
-
Airless Sprayer - 1/3 HP
600
1200
Reciprocating Saw
960
960
Electric Drill - 1/2 HP
1000
1000
Circular Saw - 7 1/4”
1500
1500
Miter Saw - 10”
1800
1800
Table Planer - 6”
1800
1800
Table Saw/Radial Arm Saw - 10”
2000
2000
Air Compressor - 1-1/2 HP
2500
2500
Figure 10 - Wattage Reference Chart
900W Generator
11
PRODUCT
SPECIFICATIONS
Generator Specifications
Rated Surge Watts . . . . . . . . . . . . . . . 1,000 Watts
Rated Running Watts . . . . . . . . . . . . . 900 Watts
Rated Maximum Current
At 120 Volts AC . . . . . . . . . . . . . .7.5 Amps
At 12 Volts DC . . . . . . . . . . . . . . .8.3 Amps
Phase . . . . . . . . . . . . . . . . . . . . . . . .Single Phase
Rated Frequency . . . . . . . . . . . . . . . .60 Hertz
Packaged Weight . . . . . . . . . . . . . . . .61 lbs.
Engine Specifications
Model
. . . . . . . . . . . . . . . . . . . . . . . .
Mitsubishi GM82
Rated Horsepower . . . . . . . . . . . . . . 2.4 at 4000 rpm
Displacement . . . . . . . . . . . . . . . . . . . 80cc
Spark Plug Type: . . . . . . . . . . . . . . . . . NGK BP6HS or
equivalent
Set Gap To: . . . . . . . . . . . . . . . . . . . . . 0.030inch (0.75mm)
Fuel Capacity . . . . . . . . . . . . . . . . . . . 1.2 U.S. gallons (4.5 l)
GENERAL MAINTENANCE
RECOMMENDATIONS
The generator warranty does not cover items that have
been subjected to operator abuse or negligence. To receive
full value from the warranty, operator must maintain
generator as instructed in this manual.
Some adjustments will need to be made periodically to
properly maintain your generator.
All adjustments in this section should be made at least
once each season. Follow the requirements in the
“Maintenance Schedule” chart shown below in Figure 11.
NOTE: Once a year you should clean or replace the spark
plug and replace the air filter. A new spark plug and clean
air filter assure proper fuel-air mixture and help your
engine run better and last longer.
GENERATOR
MAINTENANCE
Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with snow,
leaves or any other foreign material.
1 Clean more often under dirty or dusty conditions. Replace cleaner parts if very dirty.
2 Check every 10 hours or 3 months.
3 These items should be serviced by an authorized dealer, unless the owner has the proper tools and is mechanically
proficient.
Item
Operation
Each use
First Month or
25 hours
Every 3 months
or 50 hours
Engine oil
Check level
X
Change
X
X
Air cleaner
Check
X
Clean
X (1)
Spark arrester
Check Clean
X (2,3)
Spark plug
Check Clean
X
Valve clearance
Check Adjust
Fuel tank strainer
Clean
Fuel line
Check (Replace if
necessary)
Every 3 years (3)
Figure 11 – Maintenance Schedule
900W Generator
12
Check the cleanliness of the generator frequently and clean
when dust, dirt, oil, moisture or other foreign substances
are visible on its exterior surface.
NOTE: DO NOT use a garden hose to clean generator.
Water can enter engine fuel system and cause problems. In
addition, if water enters generator through cooling air
slots, some of the water will be retained in voids and
cracks of the rotor and stator winding insulation. Water
and dirt buildup on the generator internal windings will
eventually decrease the insulation resistance of these
windings.
To Clean the Generator
Use a damp cloth to wipe exterior surfaces clean.
Soft, bristle brush may be used to loosen caked on dirt
or oil.
CAUTION! NEVER insert any object or tool
through the air cooling slots, even if the engine is
not running.
A vacuum cleaner may be used to pick up loose dirt and
debris.
Low pressure air (not to exceed 25 psi) may be used to
blow away dirt. Inspect cooling air slots and opening on
generator. These openings must be kept clean and
unobstructed.
WARNING! When working on the generator
always disconnect spark plug wire from spark plug
and keep it away from spark plug.
ENGINE MAINTENANCE
Checking Oil Level
Oil level should be checked prior to each use or at least
every 5 hours of operation. Keep oil level maintained.
Changing Engine Oil
Change the oil after the first month of operation, then
every 25 hours. If you are using your generator under
extremely dirty or dusty conditions, or in extremely hot
weather, change the oil more often.
Change the oil while the engine is still warm from running,
as follows:
Remove the oil fill cover and clean area around oil drain
plug (Figure 12).
Remove oil drain plug, sealing washer, and oil filler cap.
Drain oil completely into a suitable container.
Install oil drain plug and sealing washer. Tighten securely.
Refill with recommended oil and check the level. See
page 6 for oil recommendations.
Wipe up any spilled oil.
CAUTION! Avoid prolonged or repeated skin
contact with used motor oil. Used motor oil has
been shown to cause skin cancer in certain
laboratory animals. Thoroughly wash exposed areas
with soap and water. KEEP OUT OF REACH OF
CHILDREN.
DON'T POLLUTE. CONSERVE RESOURCES.
RETURN USED OIL TO COLLECTION CENTERS.
Replace oil fill cover.
Clean/Replace Spark Plug
Check and clean the spark plug every 50 hours of
operation or every three months, whichever comes first.
This will help your engine to start easier and run better.
Remove spark plug access cover. Remove spark plug cap.
Clean the area around the spark plug.
Remove and inspect the spark plug.
Replace the spark plug if electrodes are pitted or burned
or the porcelain is cracked. Use recommended plug for
replacement.
Check electrode gap with wire feeler gauge and set spark
plug gap between 0.028 and 0.031 inch (0.7 to 0.8 mm) if
necessary (Figure 13).
Figure 12 — Oil Drain Plug
Oil Drain Plug
900W Generator
13
Reinstall spark plug.
Service Air Cleaner
Your engine will not run properly and may be damaged if
you run it using a dirty air filter element.
Check the air filter every use and clean or replace the
paper air filter element every 50 hours of operation or
every three months, whichever comes first. Clean or
replace more often if operating under dusty or dirty
conditions.
To clean or replace air filter element:
Loosen the air cleaner cover screws, remove the air
cleaner cover, and remove the element (see item
number 4, exploded view on page 22.
Wipe clean the inside of the filter housing and cover
thoroughly.
Wash the element in a solution of household detergent
and warm water, then rinse thoroughly. Or wash in
nonflammable or high flash point solvent. Allow the
element to dry thoroughly.
Soak the element in clean engine oil and squeeze out the
excess oil. DO NOT twist. The engine will smoke during
initial start-up if too much oil is left in the element.
NOTE: If you need to order a new air filter element,
please call 1-800-743-4115.
Reinstall the air cleaner element and the cover. Hand
tighten the air cleaner cover screws.
Clean Spark Arrester Screen
The engine muffler is equipped with a removable spark
arrester screen. Inspect and clean the screen every
10 hours of operation or every three months, as shown in
Figure 14:
Loosen the screw on the muffler tail pipe and remove
the spark arrester screen.
Use a brass or stiff-bristle brush to remove carbon
deposits from the spark arrester surface.
Inspect the spark arrester for breaks or tears and
replace it if necessary.
NOTE: If you need to order a new spark arrester, please
call 1-800-743-4115.
Install the clean screen in the reverse order of removal.
NOTE: If you use your generator on any forest-covered,
brush-covered or grass-covered unimproved land, it must
have a spark arrester installed. The spark arrester must be
maintained in good condition by the owner/operator.
STORAGE INSTRUCTIONS
Transporting and Storage
When transporting the generator, turn the engine switch
to “Off” and the fuel valve to “Close”. Keep the generator
level to prevent fuel spillage.
WARNING! Contact with a hot engine or
exhaust system can cause serious burns or fires. Let
the engine cool before transporting or storing the
generator.
Take care to not drop or strike the generator when
transporting. DO NOT place heavy objects on the
generator.
The generator should be started at least once every seven
days and allowed to run at least 30 minutes. If this cannot
be done and you must store the unit for more than 30 days,
use the following guidelines to prepare it for storage.
Figure 13 — Service Spark Plug
Spark Arrester
Screen
Muffler Tail Pipe
Spark Arrester
Attachment Screw
Figure 14 – Service Spark Arrester Screen
900W Generator
14
Long Term Storage Instructions
WARNING! NEVER store engine with fuel in
tank indoors or in enclosed, poorly ventilated areas
where fumes may reach an open flame, spark or
pilot light as on a furnace, water heater, clothes
dryer or other gas appliance.
Be sure the storage area is free from excessive
humidity and dust.
One Month to One Year
Drain the carburetor float bowl (see following section) and
fuel tank into a suitable container. After removal from
storage, fill with fresh fuel before starting.
More than One Year
It is important to prevent gum deposits from forming in
essential fuel system parts such as the carburetor, fuel filter,
fuel hose or tank during storage. Also, experience indicates
that alcohol-blended fuels (called gasohol, ethanol or
methanol) can attract moisture, which leads to separation
and formation of acids during storage. Acidic gas can
damage the fuel system of an engine while in storage.
To avoid engine problems, the fuel system should be
emptied before storage of 30 days or longer. Follow these
instructions:
Protect Fuel System
WARNING! Drain fuel into approved container
outdoors, away from open flame. Be sure engine is
cool. DO NOT smoke.
Drain carburetor float bowl and fuel tank into a suitable
container by loosening the drain screw (Figure 15).
Retighten drain screw before refueling.
Change Oil
While engine is still warm, change oil as described on
page 12. Refill with recommended grade.
Oil Cylinder Bore
Remove spark plug and pour about one tablespoon of
clean engine oil into the cylinder.
CAUTION! Avoid spray from spark plug hole
when cranking engine slowly.
Cover spark plug hole with rag. Crank slowly several
times to distribute oil.
Install spark plug. DO NOT connect spark plug wire.
Slowly pull the starter grip until resistance is felt. At this
point, the piston is coming up on its compression stroke
and both the intake and exhaust valves are closed.
Storing the engine in this position will help to protect it
from internal corrosion.
Generator
Clean the generator as outlined on page 12 (“To Clean
the Generator”).
Check that cooling air slots and openings on generator
are open and unobstructed.
Other Storage Tips
DO NOT store fuel from one season to another.
Replace the fuel can if it starts to rust. Rust and/or dirt
in fuel will cause problems.
If possible, store your unit indoors. BE SURE TO
EMPTY THE FUEL TANK.
Cover your unit with a suitable protective cover that
does not retain moisture.
IMPORTANT: NEVER cover your generator while engine
and exhaust area are warm.
Store generator in clean, dry area.
Carburetor Fuel
Drain Screw
Drain Screw
Access Hole
Figure 15 – Drain Fuel From Carburetor
900W Generator
15
NOTES
900W Generator
16
TROUBLESHOOTING
Problem
Cause
Correction
No AC or DC output
is available but
engine is running.
1. One of the circuit breakers is open.
2. Fault in generator.
3. Poor connection or defective cord set.
4. Connected device is bad.
1. Reset circuit breaker.
2. Contact Briggs & Stratton Power
Products service facility.
3. Check and repair.
4. Connect another device that is in
good condition.
Generator runs good
at no-load but
“bogs down" when
loads are
connected.
1. Short circuit in a connected load.
2. Engine speed is too slow.
3. Generator is overloaded.
4. Shorted generator circuit.
1. Disconnect shorted electrical load.
2. Contact Briggs & Stratton service
facility.
3. See “Don't Overload the Generator”
on page 10.
4. Contact Briggs & Stratton Power
Products service facility.
Engine will not start;
or starts and runs
rough.
1. Engine switch set to “Off”.
2. Fuel valve in the “Closed” position.
3. Dirty air cleaner.
4. Out of gasoline.
5. Stale gasoline.
6. Spark plug wire not connected to spark
plug.
7. Bad spark plug.
8. Water in gasoline.
9. Overchoked or flooded.
10. Excessively rich fuel mixture.
11. Intake valve stuck open or closed.
12. Engine has lost compression.
1. Set switch to “On”.
2. Turn fuel valve to the “Open
position.
3. Clean or replace air cleaner.
4. Fill fuel tank.
5. Drain gas tank and carburetor; fill
with fresh fuel.
6. Connect wire to spark plug.
7. Replace spark plug.
8. Drain gas tank and carburetor; fill
with fresh fuel.
9. Wait 5 minutes and re-crank engine.
10. Contact Briggs & Stratton service
facility.
11. Contact Briggs & Stratton service
facility.
12. Contact Briggs & Stratton service
facility.
Engine shuts down
when running.
1. Out of gasoline.
2. Low oil level.
1. Fill fuel tank.
2. Fill cranckcase to proper level.
Engine lacks power.
1. Load is too high.
2. Dirty air filter.
1. See “Don't Overload the Generator”
on page 10.
2. Replace air filter.
Engine “hunts” or
falters.
1. Choke is opened to soon.
2. Carburetor is running too rich or too lean.
1. Move choke to halfway position until
engine runs smoothly.
2. Contact Briggs & Stratton service
facility.
900W Generator
17
WIRING DIAGRAM
900W Generator
18
EXPLODED VIEW AND PARTS LIST – MAIN UNIT
Item Part # Qty Description
1 NSP 1 ENG, MITSUB, 2.4HP
2 187378GS 1 ROTOR
3 187411GS 1 BRG
4 187379GS 1 STATOR
5 187430GS 1 LEAD, GREEN
6 187409GS 1 BUSHING, LEAD WIRE, G790B
7 187381GS 1 RBC, 1K
8 187399GS 3 SCREW, SELF TAP, M6-12
9 187382SGS 1 FAN, COOLING
10 187388GS 1 BOLT, RTR
11 187389GS 3 BOLT, STATOR
12 187405GS 1 INSLTN, HEAT SEALED, #1
13 187384GS 1 MFFLR, SEALED
14 187407GS 1 INSLTN, HEAT SEALED, #2
15 187403GS 1 DUCT, AIR
Item Part # Qty Description
16 187392GS 2 PHMS, M6-1.0, W/L/FW
17 187383GS 1 BASE, GEN
18 187390GS 4 BOLT, FLNG, M6-1.0 X 10
19 187385GS 4 MNT, VIBR
20 187427GS 4 HHCS, FLNG, M8-1.25 X 12
21 187424GS 1 NUT, WING, M5 X 0.8
22 187423GS 1 NUT, M5 X 0.8
23 187419GS 2 WSHR, LOCK
24 187420GS 2 WSHR, FLAT
25 187401GS 2 NUT, M8-1.25, FLANGE
26 187415GS 1 PHMS, M5-0.8 X 20
27 187413GS 2 CNNCTR
28 187434GS 4 HHCS, FLNG
29 187431GS 1 STND, ENG
900W Generator
19
Item Part # Qty Description
1 187436GS 1 CAP, FUEL
2 187439GS 1 PACKING, TANK
3 187438GS 1 FLTR, FUEL
4 187769GS 3 U-PACKING
5 187437GS 1 TANK, FUEL, 4.5L
6 187766GS 1 DECAL, CHOKE
7 187756GS 4 BOLT, COVER (M5-16)
8 187875GS 1 HSG, GEN, MFFLR
10 187772GS 1 COVER, SPARK PLUG
11 187757GS 5 BOLT, COVER (M6-16)
12 187760GS 11 PHMS, M4-12 W/FW
13 187435GS 1 CVR, MFFLR, GEN
14 187775GS 3 BOLT, MFFLR CVR (M6-16)
15 191436GS 1 DECAL CAUTION HOT
16 187774GS 4 BOLT, COVER (M6-20)
17 187761GS 8 NUT, M4X0.6 W/FW
18 187463GS 1 INSLTN, MFFLR
19 187874GS 1 HSG, GEN
20 NSP 1 DECAL, EMISSIONS
21 187457GS 1 CONDENSER, 300V
22 191528GS 1 DECAL, WARNING
23 187759GS 2 BOLT, COVER (M5-10)
24 187462GS 1 DIODE, BRIDGE
Item Part # Qty Description
25 187371AGS 1 BOTTLE, OIL
26 192284GS 1 DECAL, LWR PANEL
27 187773GS 1 COVER, OIL FILL
28 187460GS 1 CB, DC
29 187454GS 1 CB, 8A, 125V
30 187873GS 1 OUTLET, ACCESSORY DC
31 187450GS 1 SWITCH, ENG, ON/OFF
32 187812GS 1 CPNL
33 187456GS 1 RECPTCL, 15A, 125V
34 187763GS 1 DECAL, CAUTION OIL
35 187876GS 1 CABLE, BATTERY CHARGE
36 192283GS 1 DECAL, UNIT
37 191545GS 1 DECAL, FUEL SHUTOFF
38 187447GS 1 INSLTN, HTSHLD, TANK #1
39 187448GS 1 INSLTN, HTSHLD, TANK #2
40 187442GS 2 BRKT, TANK, FUEL
41 187758GS 1 BRKT, FUEL COCK
42 187443GS 1 COCK, FUEL
43 187770GS 1 PHMS, M5-10 W/FW
44 187579GS 1 CLIP, FUEL HOSE
45 187440GS 1 FLTR, FUEL
46 187578GS 1 HOSE, FUEL
EXPLODED VIEW AND PARTS LIST – MAIN UNIT
900W Generator
20
EXPLODED VIEW AND PARTS LIST – ENGINE
Cylinder Block, Cylinder Head
Item Part # Qty Description
1 187404GS 1 ASSY, CYL HEAD
2 187406GS 2 TPPT, CYL HEAD
3 187408GS 2 VLV, EXH
4 187410GS 2 SPRNG, VLV
5 187412GS 2 RTNR, VLV SPG
6 187414GS 2 ROD, PUSH
7 187416GS 1 ASSY, RCKR, ARM
8 187417GS 2 NUT, CYL HEAD
9 187418GS 2 SCRW, ADJST
10 187421GS 1 PLT, CYL HEAD
Item Part # Qty Description
11 187422GS 1 SEAL, VLV STEM
12 187423GS 4 NUT, M5 X 0.8
13 187426GS 4 BOLT, FLNG
14 187428GS 2 PIN, DWL
15 187429GS 1 GSKT, HEAD
16 187468GS 1 CVR, VALVE
17 187470GS 4 BOLT, VALVE CVR
18 187472GS 1 GSKT, VALVE CVR
19 187569GS 2 BOLT, STUD
Item Part # Qty Description
1 187380GS 1 BLOCK, CYL
2 187386GS 1 ASSY, GOV, GEAR
3 187387GS 1 SLIDER, GOV
4 187391GS 1 SHFT, GOV
5 187393GS 2 PLUG, DRAIN
6 187394GS 2 SEAL, OIL
7 187395GS 1 BRG, BALL
8 187400GS 1 WSHR, CYLBLOCK
9 187402GS 2 GSKT, CYLBLOCK
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

Briggs & Stratton 01532-2 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur
Ce manuel convient également à