Save These Instructions
Contact-Cooled Rotary Screw Air Compressor
R30, R37, R45, R55, R75, R90, R110, R132, R160
Product Information
Information produit
FR
Información del producto
ES
Product Information
EN
Informações do produto
PT
93014.15.06
PRINT LANGUAGE
ENGLISH
SPANISH
FRENCH
PORTUGUESE
EN
EN-2 80447162 Rev B
ABOUT THIS MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
TRANSPORTATION/RECEIPT/HANDLING . . . . . . . . . . . . . . . . . . . . .3
Transportation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Receipt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Unpacking and Handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Long Term Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Location in Plant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Discharge and Condensate Piping . . . . . . . . . . . . . . . . . . . . . . . . . . .4
General Electrical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Special Electrical Considerations for Variable Speed Drive (VSD)
Compressors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Primary Input Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
How to Ground. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
How to Find Which System Is Used. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
High Voltage Conditions and Secondary Protection. . . . . . . . . . . . . . 6
Power Factor Compensation Capacitors. . . . . . . . . . . . . . . . . . . . . . . . . 6
Power Supplied By Dedicated Transformer or Generator . . . . . . . . . 7
Control Power Transformer Connections . . . . . . . . . . . . . . . . . . . . . . . . 7
Water-cooled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Cooling Water Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Venting the water system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Draining the water system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Water quality recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Integrated Dryer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Environmental Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
GENERAL INFORMATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Integrated Dryer Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
OPERATING INSTRUCTIONS FOR VARIABLE SPEED DRIVE VSD
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Basic Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Prior to starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Initial check sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Start sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Stop sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Warm up mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Blower control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Emergency stopping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Restarting after emergency stopping . . . . . . . . . . . . . . . . . . . . . . . . . . 11
OPERATING INSTRUCTIONS XE90M CONTROLLER. . . . . . . . 12
User Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
LED status icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Command keys. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Navigation keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Display layout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Folder navigation and icons. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Page navigation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Accessing parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Dashboard icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Folder Options (Fixed Speed) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Home folder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Operator settings folder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Events folder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Trip history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Maintenance folder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
General settings folder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Status folder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Factory settings folder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Folder Options (Variable Speed). . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Home folder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Operator settings folder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Events folder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Trip history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Maintenance folder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
General settings folder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Status folder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Factory settings folder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
OPERATING INSTRUCTIONS XE70M CONTROLLER. . . . . . . . 33
User Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Led Status Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Command Keys. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Navigation Keys. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Display layout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Folder navigation and icons. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Page navigation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Accessing parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Dashboard icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Dashboard Status Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Fixed Speed Compressor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Home folder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Operator Settings folder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Events folder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Trip History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Maintenance folder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
General Settings folder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Integral Sequencing folder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Status folder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Factory Settings folder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Variable Speed Compressor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Home folder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Operator Settings folder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Events folder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Trip History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Maintenance folder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
General Settings folder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Integral Sequencing folder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Status folder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Factory settings folder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
MODBUS CONNECTION AND CONTROL. . . . . . . . . . . . . . . . . . . . 55
Connection to the Modbus Network . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
RS-485 Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Modbus Address Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Modbus Master Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
R4 to 37 kW Fixed Speed Modbus Table . . . . . . . . . . . . . . . . . . . . . . . . 56
R5.5 to 37 kW Variable Speed Modbus Table. . . . . . . . . . . . . . . . . . . . 58
XSERIES SYSTEM CONTROLS CONNECTION . . . . . . . . . . . . . . . 61
RS-485 Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
RS-485 Address Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Enabling System Control Capabilities . . . . . . . . . . . . . . . . . . . . . . . . . . 61
NOTICES AND DISCLAIMERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
CONTENTS
93014.15.06
80447162 Rev B EN-3
EN
SAFETY
Locate, read, understand and follow all Danger, Warning, Caution, and
Operating Instructions on the product and in all Manuals. Failure to
comply with safety precautions described in the manuals supplied with
the product, this manual or any of the labels and tags attached to the
product may result in death, serious injury or property damage.
Check that all labels, tags and data (name) plates are in place and legible.
It is your responsibility to make this information available to others.
If you have any questions about safety or procedures not included in
this manual, ask your supervisor or contact any Ingersoll Rand o ce or
quali ed Ingersoll Rand distributor.
TRANSPORTATION/RECEIPT/HANDLING
Transportation
Ensure machine is secured against movement during transportation.
Receipt
Before signing the delivery receipt, inspect for damage and missing parts. If
damage or missing parts are apparent, make the appropriate notation on the
delivery receipt, then sign the receipt. Immediately contact the carrier for an
inspection.
All material shall be held in the receiving location for the carriers inspection.
Delivery receipts that have been signed without a notation of damage or
missing parts are considered to be delivered clear. Subsequent claims are
then considered to be concealed damage claims. Settle damage claims
directly with the transportation company.
If you discover damage after receiving the compressor (concealed damage),
the carrier shall be noti ed within 15 days of receipt and an inspection shall
be requested by telephone with con rmation in writing. On concealed
damage claims, the burden of establishing that the compressor was
damaged in transit reverts back to the claimant.
Read the compressor nameplate to verify it is the model ordered, and read
the motor nameplate to verify it is compatible with your electrical conditions.
Make sure electrical enclosures and components are appropriate for the
installation environment.
Unpacking and Handling
The compressor will normally be delivered with a polyethylene or other
cover. If a knife has to be used to remove this cover, ensure that the exterior
paintwork of the compressor is not damaged.
Incorporated within the base of the compressor are slots to enable a fork lift
truck to move the compressor. Ensure truck forks are fully engaged on both
sides. Alternatively a special lifting frame can be used to enable a crane or
hoist to move the compressor. Use only marked lifting points.
Once the packaging and pallet are discarded and the compressor is in its
nal position, remove the yellow painted transit brackets from the resilient
mounts and store for future use or discard.
For Variable Speed and Fixed Speed (R30-37 kW)
(2) brackets from the Airend and separator tank support.
(1) bracket from the motor mounting bracket.
For Variable Speed Drive (VSD) (R37e-160 kW)
(3) brackets at the separator tank
(1) bracket from the air end discharge elbow.
(1) bracket from the air end support.
For Fixed Speed (FS) (R37e-160 kW)
(3) brackets at the separator tank
(1) bracket from the air end support.
(1) bracket from the motor mounting bracket.
Long Term Storage
If the product will not be commissioned within six months of receipt, it
should be prepared for long term storage. Please contact Ingersoll Rand for
details.
ABOUT THIS MANUAL
The purpose of this manual is to provide site planning, installation and operation guidelines for the compressor.
For supporting documentation refer to Table 1.
Table 1 : Product Manuals
Publication Product
Part/Document Number by Region
Americas EMEIA * Asia Paci c
Product Safety Information Manual All 80446313 80446156 80446321
Product Maintenance Manual All 80447170 80447196 80447212
Product Parts Information Manual
R30-37 24342156
R37-45 80448095
R55-75 80447592
R90-160 kW Single-Stage 80446057
R90-160 kW Two-Stage 80446065
* Europe, Middle East, India and Africa
Product speci cation sheets and reference drawings are also available.
93014.15.06
EN
EN-4 80447162 Rev B
INSTALLATION
Location in Plant
Figure 1 : Typical Air System
2
4
5
4
3
8
6
7
1
Key
Compressor
Air Receiver Dry Tank
Air Dryer
Compressed Air Filters
System Demand Points
Vent/Drain Trap
Isolation Valve
Air Receiver (“Wet Tank”)
Customer can install  exible element between machine and pressure
system to avoid vibration transmition.
The compressor can be installed on any level  oor capable of supporting
it. A dry, well ventilated area where the atmosphere is as clean as possible
is recommended.
The area selected for the location of the compressor should be free of
dust, chemicals, metal  lings, paint fumes and overspray.
Hard surfaces may re ect noise with an apparent increase in the decibel level.
When sound transmission is important, a sheet of rubber or cork can be installed
beneath the compressor to reduce noise. Flexible piping may be required.
See the general arrangement drawing for minimum space requirements
for normal operation and maintenance.
Minimum space in front of the control panel door as required by national
or local codes shall be maintained.
Ambient temperatures higher than 46 °C (115 °F) shall be avoided, as well
as areas of high humidity.
NOTICE
A minimum of 1 m (3.3 ft) all around the compressor is recommended.
If headroom is restricted, then the exhaust should be ducted or
de ected away from the compressor.
Screw type compressors should not be installed in air systems with
reciprocating compressors without means of isolation such as a common
receiver tank. It is recommended that both types of compressor be
piped to a common receiver tank using individual air lines.
The compressor is shipped with the shipping restraints in place.
Ensure that these are removed to allow free movement of the drive
assembly during operation. Each restraint is painted yellow.
Discharge and Condensate Piping
See Figure 1.
It is essential when installing a new compressor (1) to review the total air
system. This is to ensure a safe and e ective total system.
One item which should be considered is liquid carryover. Installation of air
dryers (3) is always good practice since, when properly selected and installed,
they can reduce any liquid carryover to zero.
An air receiver tank (2) is recommended to ensure that the total system
volume is su cient.
1.
2.
3.
4.
5.
6.
7.
8.
Discharge piping should be at least as large as the discharge connection
of the compressor. All piping and  ttings should be suitably rated for the
discharge pressure. Discharge piping should not exert any unresolved
moments or force on the compressor.
It is good practice to install line  lters (4).
Include a vent or drain trap (6) to vent the discharge pipework downstream
from the minimum pressure check valve located on the separator tank and
upstream of the  rst system isolation valve (7).
This compressor has an internal discharge check valve. An external check
valve is not required. An isolation valve (7) is required within 1 m (36 in) of the
compressor discharge.
NOTICE
There should be no plastic or PVC piping attached to this compressor
or used for any lines down stream with exception of condensate
removal lines.
NOTICE
The discharged air contains a very small percentage of compressor
coolant and care should be taken to ensure that downstream
equipment is compatible.
When two rotary compressors are operated in parallel, provide an isolation
vaIve (7) and drain trap (6) for each compressor before the common receiver.
Ensure the discharge piping is arranged to prevent water from being forced
into the non-operating compressor.
A wet tank (8) is recommended in cases where the air dryer is a regenerative
desiccant type to prevent short cycling the compressor during the purging
cycle when plant air demand is slow.
The built-in after-cooler reduces the discharge air temperature below the
dew point (for most ambient conditions). Therefore, considerable water vapor
is condensed. To remove this condensation, each compressor with a built-in
after-cooler is furnished with a combination condensate separator/trap.
A dripleg assembly and isolation valve should be mounted near the
compressor discharge. A drain line should be connected to the condensate
drain in the base.
NOTICE
The drain line shall slope downward from the base to work properly.
For ease of inspection of the automatic drain trap operation, the drain
piping should include an open funnel. The drain line must have a
minimum inside diameter of 8 mm (5/16 in)
NOTICE
For low volume systems that may not include an air receiver tank (2),
compressor response time may need adjusting. Contact your local
Ingersoll Rand service provider.
NOTICE
Do not use the compressor to support the discharge pipe.
93014.15.06
80447162 Rev B EN-5
EN
General Electrical
A quali ed electrician shall perform all electrical installations and service.
The compressor shall be properly grounded / earthed in compliance with all
applicable standards and regulations (local, state, country, federal, etc.).
Installation of this compressor shall be in compliance with all applicable
standards and regulations (local, state, country, federal, etc.).
The compressor shall have its own isolator situated adjacent to it. The fuse
protecting the circuit and the compressor shall be selected in accordance
with recognized code requirements on the basis of the data provided in the
speci cation sheet.
Feeder cables shall be sized to ensure that the circuit is balanced and not
overloaded by other electrical equipment. The length of wiring from a
suitable electrical feed point is critical as voltage drops may impair the
performance of the compressor.
NOTICE
For VSD, cable sizes may vary considerably so the line reactor is
equipped with copper bus connections. These connections can accept
bolts between 6 mm and 12 mm.
Feeder cable connections to incoming terminals L1-L2-L3 shall be tight and
clean.
The applied voltage shall be compatible with the compressor data plate
ratings.
The control circuit transformer has di erent voltage tappings. Ensure that
these are set for the speci c applied voltage prior to starting.
Remove the blind plate to cut a hole for incoming power connection. If it
is necessary to make a hole in the control box in a di erent location, care
should be taken to not allow metal shavings to enter the starter and other
electrical components within the box. If another hole is used, the original
hole shall be blocked o .
The feeder cable shall be suitably glanded in to the starter box to maintain
proper ingress protection. Fixed speed starter boxes are rated for NEMA 4
/IP65, and variable speed drive starter boxes are rated for NEMA 12/IP54.
For variable speed drive starter boxes, the feeder cable shall be glanded to
ensure that dirty air does not by-pass the  lters.
On completion of electrical installation, check that the blower or fan motor
rotation is correct.
Variable speed drive compressors are designed for use, where the electricity
supply is separated from nearby residential and commercial areas. If the
compressor is to be used in a light industrial, residential or commercial
environment where the local supply network is shared, further Radio
Frequency (RF) screening measures may be required. Consult your local
distributor/supplier for details of the optional RF  lter.
Variable speed drive compressors have an anti-condensation heater
and thermostat in the electrical box. This circuit can be connected to
an independent electrical supply of either 110 V or 230 V single phase,
dependent on the country of installation. The supply shall be suitably fused
and an independent isolator installed adjacent to the compressor. Verify that
the thermostat is adjusted to 29 ˚C (85 ˚F). This shall be done in accordance
with recognized codes. It is good practice, and sometimes mandatory,
to display suitable signs warning that the compressor has two separate
electrical supplies which both shall be isolated before any work is attempted.
For Variable speed drive compressors, the heater circuit can also be supplied
from the 110 V tapping of the control transformer and connected as shown
on the schematic wiring diagram furnished separately from this manual.
NOTICE
Main and fan motor insulation shall be tested by a quali ed electrician
prior to initial start-up or following an extended shutdown period in
cold and damp conditions.
Special Electrical Considerations for Variable Speed
Drive (VSD) Compressors
Primary Input Power Supply
The primary input power for the compressor can come from di erent
transformer sources and con gurations. The most typical sources and
con gurations are a wye secondary and a delta secondary.
Figure 2 : Wye and Delta Con gurations
Wye
Delta
How to Ground
In most conditions, you must ground a wye system. Refer to local electrical
codes. When you ground a wye system, the voltage to ground becomes
stable and controlled. This prevents a system from damage by conditions that
cause high voltage to ground. It is typical to ground the neutral (center) point
of a wye source.
It is not necessary to ground a delta system. If you ground a delta system,
ground it to one phase. You can also ground it to a center tap on one phase.
Figure 3 : Wye and Delta Grounding
Grounded wye(typical)
Corner grounded delta(not
typical)
Ungrounded
delta(typical)
Center grounded delta(not
typical)
Refer to electrical codes to ground the compressor to a permanent protective
ground connection. The compressor electrical enclosure contains an
electrical power ground terminal that has the identi cation of “PE”. The
typical primary input power is a four-wire connection with three power wires
and a ground wire. Connect the ground wire to the ground terminal.
NOTICE
If there are only three power wires and no ground wire, connect the
ground terminal to a correct building ground. Do not let the enclosure
frame  oat without an electrical connection to a power ground source.
93014.15.06
EN
EN-6 80447162 Rev B
How to Find Which System Is Used
NOTICE
Use a multimeter to measure the voltage. All voltage indications can
change plus or minus 10%.
In a grounded wye connected 480-volt network:
Each phase to ground (neutral) voltage is approximately 277 volts (480/
sqrt3).
277 volts is a nominal indication for 480 volt systems.
Other voltage indications are possible for 380, 415, 440 and 575 volt
systems. See Table 2.
The phase-to-phase voltage is the same as the primary supply voltage
(575, 480, 460, 440, 415, or 380 volts).
NOTICE
You must disconnect the two Electro-Magnetic Compatibility (EMC)
lters in a wye network that has a high resistance neutral connection
more than 30 ohms. See “Disconnecting the Electro-Magnetic
Compatibility (EMC) Filters”.
In an ungrounded delta connected network:
The network is capacitively grounded.
Stray capacitances are connected between each phase conductor to
ground.
All phase voltages to ground are approximately 277 volts for a 480-volt
network.
There can be many di erent indications because of the capacitive ground.
The phase-to-phase voltage is the same as the primary supply voltage
(575, 480, 440, or 380 volts).
The primary function of an ungrounded delta network is to let uninterrupted
power occur during a ground fault. At this time, the ungrounded network
is referenced to ground. The primary circuit breaker opens only when two
phases are connected to ground. Thus, it is possible to have one of the three
phases of an ungrounded delta network connected to ground or the network
be ungrounded at the time of compressor installation, but have a grounded
phase at a future time.
NOTICE
You must disconnect the two Electro-Magnetic Compatibility (EMC)
lters in a delta network that is not grounded. If you do not do this,
damage will occur to the  lter and to the VSD. This voids the factory
warranties. See “Disconnecting the Electro-Magnetic Compatibility
(EMC) Filters”.
In a delta connected network:
Only two phases to ground have a voltage, while the third phase has zero
volts. The phase with zero volts is grounded.
The two ungrounded phase voltages are the same as the primary supply
(480 volts to ground for a 480-volt system).
The phase-to-phase voltage is the same as the primary supply voltage
(480, 440, or 380 volts).
NOTICE
With all compressors that have a variable speed drive for the primary
drive, connect the ground to the L2 input of the compressor. If you do
not obey this procedure, the compressor does not operate.
NOTICE
If you  nd a grounded phase during installation, it is important to
know if the grounded phase is intentional (grounded) or accidental
(ungrounded with a ground fault condition present).
Table 2 : Input Voltage Rating
Nominal Voltage Rating (VAC) 380-460
Phase 3
Hertz 50/60
Min./Max. Voltage Tolerance (%) 400-460 V ± 10
380 V +10, -6
Min. /Max. Voltage Imbalance Between Phases (%) 3
Min./Max. Frequency Tolerance (%) ± 5
NOTICE
Ratings that do not fall in these limits can cause damage to the
compressor and make all factory warranties void.
High Voltage Conditions and Secondary Protection
A compressor with a variable speed drive contains Metal Oxide Varistors
(MOV). The MOV prevent damage to the VSD from typical voltage conditions.
Very high voltage conditions can cause damage to the MOV and the VSD.
These are examples of very high voltage conditions:
lightning storms
switching of power factor capacitors
welders
thyristors
If there are very high voltage conditions, you must add secondary protection
to prevent damage to the compressor.
NOTICE
Damage to the MOV shows that the compressor was exposed to very
high voltage conditions.
Damage to the MOV because of very high voltage makes the factory
warranty and the extended contract warranty void.
Power Factor Compensation Capacitors
Power factor compensation is not necessary for a compressor that contains a
variable speed drive. Nevertheless, if you connect the compressor to a system
that includes compensation capacitors, obey these instructions:
Do not connect a high-power capacitor to the power line while the
compressor is connected to the primary power. High voltage conditions
can open the compressor protection circuits or they can cause damage to
the compressor.
If you increase or decrease the capacitor load gradually when the
compressor is connected to the power line, make sure the connection
steps are su ciently low not to cause voltage transients that can open
the compressor protection circuits or cause damage to the compressor.
Check that the power factor compensation unit is correct for use in
systems with AC drives. The compensation unit must typically have a
blocking reactor or harmonic  lter.
Do not connect any devices to the output of the AC drive in the
compressor.
NOTICE
If you do not obey the electrical installation instructions, the factory
warranty and any extended contract warranty is void.
Disconnecting the Electro-Magnetic Compatibility (EMC) Filters
On some types of electrical power systems, you must disconnect the
internal Electro-Magnetic Compatibility (EMC)  lters. If you do not do this,
the electrical power system is connected to ground potential through the
EMC  lter capacitors. This can cause a dangerous situation and it can cause
damage to the variable speed drive.
93014.15.06
80447162 Rev B EN-7
EN
Disconnect the two EMC  lters if the electrical power system is:
ungrounded ( oating)
a high-resistance ground system (greater than 30 ohms)
a corner- grounded delta system.
WARNING
Do not try to install or remove the EMC  lters and jumpers while
power is applied to the compressors input terminals.
NOTICE
If you disconnect the internal EMC  lters, the variable speed drive
does not agree to the European requirements for Electro-Magnetic
Compatibility. If you operate the compressor without the EMC  lters,
the compressor can cause unwanted interference with electronic
devices. You can continue to operate the compressor without the EMC
lters only if Electro-Magnetic Compatibility is not necessary in your
area.
NOTICE
You must remove the two jumpers (For R37e-160 kW only). One
jumper is in the MOV/EMC metal box at the bottom of the compressor.
The other jumper is on the Printed Circuit Board (PCB) found on the
input buss bars to the drive.
Figure 4 : Location of First Jumper
A – First jumper
Figure 5 : Location of Second Jumper
A – Power
interface board
(located
underneath)
B – DC Bus sensing
board
C – Control board
D – EMC board
E – Cooling fan
F – Second jumper
NOTICE
The machine may not meet EMC requirement for connecting to a
mains network that is shared with domestic premises. If connection to
mains that are shared by other buildings for domestic use is required,
an additional EMC  lter may be required.
Power Supplied By Dedicated Transformer or Generator
High Impedance Power Source
The compressor can operate in industrial electrical networks that have
a short-circuit power 15 times greater than the rated power of the drive
(line impedance less than seven percent). Make sure that the network is
correct if you operate the compressor on a generator set or on a dedicated
transformer.
We recommend that you open the link that connects the Electro-Magnetic
Compatibility  lter capacitors to the ground point if the installation has the
following characteristics:
the distribution power network has no connection to ground and
the short-circuit current at the drive connection point and its rated
current has a ratio lower than 30.
Low Impedance Power Source
The variable speed drive can experience low impedance if the installation has
the following characteristics:
the compressor is installed near to the medium voltage/low voltage
(MV/LV) power supply transformer, and
a bank of power factor correction capacitors are connected in parallel at
the secondary side of the transformer.
The risk of a high voltage surge at the equipment terminals is high in the
condition that the voltage decrease > at the primary side of the transformer.
Example of line impedance calculation in percent
For a compressor with a rated input current of 100 amps and a line power
supply with short-circuit current capacity of 5000 amps, the line impedance is
two percent (100 A/5000 A).
Control Power Transformer Connections
The control circuit transformer has di erent voltage primary taps for di erent
power line voltage levels. Make sure that the taps are set for the correct
applied voltage before you start the compressor.
Figure 6 : Control Power Transformer Connections
93014.15.06
EN
EN-8 80447162 Rev B
Water-cooled
Cooling Water Piping
NOTICE
Water piping to and from the compressor package shall be at least
as large as the package connection size. Do not undersize the water
piping.
Isolation valves with side drains should be installed on both the inlet and
outlet lines. To maintain cooler cleanliness and reliability, it is important to
install a strainer of 2 mm mesh size on the inlet line. Strainers are available
from Ingersoll Rand.
For sea water applications (sea water option only) a zinc anode is not
recommended as it will deteriorate the copper oxide  lm on the 70/30
copper-nickel alloy tubes in contact with sea water. To minimize galvanic
corrosion and provide the greatest corrosion protection to the coolers, it
is strongly recommended that a section of iron pipe (>00 mm length) be
connected as close as possible to the air compressor package water inlet
connection. The iron pipe will act as the sacri cial anode for the copper-
nickel tubes and therefore shall be considered a regular maintenance and
replacement item. For this reason, the section of iron pipe should be installed
so that it can be easily replaced (e.g. with a union joint.).
The air compressor has a normally closed solenoid valve that is  tted to
the water outlet side within the package. The valve is wired into the air
compressor control circuit and closes when the compressor stops.
Carefully inspect the water system before installing the air compressor
package. Ensure that the piping is free of scale and deposits that may
restrict water  ow to the air compressor package. If water cleanliness is poor,
ltration installed on the water inlet pipe line is recommended.
Proper operation of the compressor requires that the cooling water  ow
be provided at a maximum supply temperature of 46 °C (115 °F). See the
compressor engineering data sheets for cooling water  ow rates.
Water temperature and pressure gauges should be installed in the water
piping for use in any fault  nding of the water system. Water pressure should
ideally be between and 5 bar (43 .5 and 72.5 psi) but shall not be above
10 bar (145 psi).
Water cleanliness is also extremely important. Cleaning of coolers as a result
of fouling is a customer responsibility. Therefore, it is highly recommended
that proper water quality shall meet the requirements listed in WATER
QUALITY RECOMMENDATIONS later in this section.
Venting the water system
Air should be vented from the water side of the system to avoid poor
performance and water hammer. Since the air compressor uses di erent
type heat exchangers depending on your selection of “fresh water cooled”
or “harsh water cooled” system, the venting procedure is di erent. Be sure to
use the correct procedure below:
Fresh water coolers (brazed plate heat exchangers):
Disconnect the water stop valve in the water outlet line of the
compressor.
Open the inlet water valve(s) to allow the water to  ow to the
compressor.
Allow all the air to escape from the system and observe water at the
water outlet port.
Connect the water stop valve.
Harsh water coolers (shell and tube heat exchangers):
Locate the water system vent cocks on top of the after-cooler and oil
cooler.
Open the water valve(s) allowing water to  ow to the package.
Open the vent cocks and allow all air to escape from the system. When
water is observed at the vent cocks, close them.
1.
2.
3.
4.
1.
2.
3.
Draining the water system
Should it become necessary to completely drain the water system, use the
following procedures speci c to the water cooled option you have.
Fresh water coolers (brazed plate heat exchangers):
Disconnect the inlet water line from the connection located at the rear
of the compressor.
Disconnect the water stop valve in the water outlet line of the
compressor.
Allow the system to completely drain.
Harsh water coolers (shell & tube heat exchangers):
Disconnect the inlet and discharge water lines from the connections
located at the rear of the compressor.
Locate the after-cooler and oil cooler. Remove the drain plugs located
at the bottom of the coolers.
Open the vent ports in the top of the after-cooler and oil cooler.
Allow the system to completely drain.
Adjusting the after-cooler trim valve
See the piping and instrumentation diagram provided separately from this
manual. The coolers are piped in a “parallel” water  ow arrangement with a
manual trim valve controlling the  ow through the after-cooler. The after-
cooler trim valve is factory set and should not need adjusting but if disturbed
use following procedure.
Close valve fully clockwise and then open two full turns.
With the compressor running loaded observe the package discharge
temperature on the controller display. It should be approximately 8 °C
(15 °F) above the water inlet temperature.
If the temperature is too high, open the valve ¼ turn and wait one
minute. If the temperature is too low, close the valve ¼ turn and wait
one minute. Repeat the incremental movements until the desired
temperature is reached.
Put a Warning − Do Not Adjust” label on the valve or  t a lock.
Water quality recommendations
Water quality is often overlooked when the cooling system of a water-
cooled air compressor is examined. Water quality determines how e ective
the heat transfer rate, as well as the  ow rate, will remain during the life of
the compressor. It should be noted that the quality of water used in any
cooling system does not remain constant during the operation of the system.
Evaporation, corrosion, chemical and temperature changes, aeration, scale
and biological formations a ect the water makeup. Most problems in a
cooling system  rst appear as a reduction in the heat transfer rate, then in a
reduced  ow rate or increased pressure drop, and  nally with damage to the
system.
Scale: Scale formation inhibits e ective heat transfer, yet it does help
prevent corrosion. Therefore, a thin uniform coating of calcium carbonate
is acceptable on the inner surface. Perhaps the largest contributor to scale
formation is the precipitation of calcium carbonate out of the water. This is
dependent on temperature and pH level. The higher the pH value, the greater
the chance of scale formation. Scale can be controlled with water treatment.
Corrosion: In contrast to scale formation is the problem of corrosion.
Chlorides cause problems because of their size and conductivity. Low pH
levels promote corrosion, as well as high levels of dissolved oxygen.
Fouling: Biological and organic substances (slime) can also cause problems,
but in elevated temperature environments such as cooling processes they
are not a major concern. If they create problems with clogging, commercial
shock treatments are available.
To ensure good operation life and performance of the compressor cooling
system, the recommended acceptable ranges for di erent water constituents
are included below:
1.
2.
3.
1.
2.
3.
4.
1.
2.
3.
4.
93014.15.06
80447162 Rev B EN-9
EN
Table 3 : Acceptable Limits for Cooling Water Constituents
ACCEPTABLE MAXIMUM LIMITS
Substance Test Interval Fresh Water
(Brazed Plate Heat Exchanger)
Dirty Water / Sea Water
(Shell & Tube Heat Exchanger)
Langelier Index (LI) Monthly 0 to 1 -0.5 to 2.5
Ammonia [NH3 ], ppm Monthly <1 <2
Ammonium [NH4-1], ppm Monthly <2 <5
Chlorides [Cl-], ppm Monthly <80 <1000
Copper [Cu], ppm Weekly <0.01 <0.5
Dissolved Oxygen (DO) [O2], ppm Monthly <0.1 <3
Iron + Manganese [Fe + Mn], ppm Monthly <0.3 <2
Nitrate [NO3 -], ppm Monthly <100 <125
Oil & Grease, ppm Monthly <5 <5
Silicon Dioxide (silica) [SiO2], ppm Monthly <30 <100
Sulfates [SO4-2], ppm Monthly <70 <250
Integrated Dryer
Do not connect condensate drains common to other pressurized drain
lines in a closed circuit. Make sure the out ow from the condensate drains
is unimpeded. Connect the condensate piping in such a way to ensure that
sound levels are kept to a minimum during drainage.
Ensure that all condensate is disposed of in a responsible manner, in
compliance with all applicable standards and regulations (local, state,
country, federal, etc.).
The ambient air around the dryer and compressor shall not contain solid
or gaseous contaminants. All compressed and condensed gases can
generate acids or chemical products which may damage the compressor or
components inside the dryer. Take particular care with sulphur, ammonia,
chlorine and installations in marine environments.
Environmental Limits
The standard compressor package is designed for the following conditions:
Indoors only
Area not considered to be a high dust area.
Ambient temperature range 2 to 46 °C (5-115 °F)
Ingersoll Rand o ers the following options for  xed speed compressors that
extend the environmental limits:
Outdoor modi cation
Low ambient option (-23 to 46 °C / -15 to 115 °F) at sea level
High ambient option (2 to 55 °C / 5 to 13 1 °F) at sea level
High dust air  lter
High dust package  lter
93014.15.06
EN
EN-10 80447162 Rev B
GENERAL INFORMATION
The compressor is an electric motor driven, contact cooled screw compressor,
complete with all necessary components piped, wired and baseplate
mounted. It is a totally self contained air compressor package.
The standard compressor is designed to operate in an ambient range of 2 °C
to 46 °C (35 °F to 115 °F). The standard maximum temperature of 46 °C
(115 °F) is applicable up to an elevation of 1000 m (3280 ft) above sea level.
Above this altitude, signi cant reductions in ambient temperature are
required if a standard motor is to be used.
The compressor is managed by the onboard electronic controller. The
controller and drive system operate together to vary the speed of the
compressor to deliver compressed air at the target pressure.
For  xed speed (FS) models, the capacity is automatically controlled via
‘ON-OFF LINE’. The compressor will operate to maintain a set discharge line
pressure and is provided with an auto restart system for use in plants where
air demand varies widely.
Panel instrumentation is provided to indicate the compressor operating
conditions and general status.
The air/coolant mixture discharges from the compressor into the separation
system. This system removes all but a few ppm of the coolant from the
discharge air. The coolant is returned to the cooling system and the air passes
to the after-cooler and out of the compressor through the moisture separator.
Air is pulled into the compressor by the cooling blower and through the
coolant cooler and after-cooler.
By cooling the discharge air, much of the water vapor naturally contained in
the air is condensed and is drained from the built-in moisture separator and
drain.
The coolant system consists of a sump, cooler, thermostatic valve and a
lter. When the compressor is operating, coolant is forced by air pressure
from the separator tank to the thermostatic element. The position of the
element (a direct result of coolant temperature) will determine whether the
coolant circulates through the cooler, bypasses the cooler, or mixes the two
paths together to maintain an optimum compressor discharge temperature.
This temperature is controlled to preclude the possibility of water vapor
condensing. By injecting coolant at a su ciently high temperature, the
discharge air coolant mixture temperature will be kept above the dew point.
For variable speed drive models, the system is enhanced by a control logic
that varies the cooling blower speed dependent on the intake and discharge
temperatures and hence controls the injection temperature even closer while
saving blower motor energy.
The compressor is provided with a temperature sensor which will shut the
compressor down in case of excessive temperature. This setting is typically
109 °C (228 °F).
E ective coolant  ltration is provided by the use of a screw on, heavy duty
coolant  lter.
NOTICE
Fixed speed compressors should not be connected to variable speed
drives. Please contact your local Ingersoll Rand representative before
inverter duty conversion.
CAUTION
For  xed speed models, the compressor may not reach its normal
operating temperature during periods of low demand. Sustained
operation at low demand can result in the buildup of condensate in
the coolant. If this situation occurs, the lubricating characteristics
of the coolant can be impaired, which may lead to damage of the
compressor.
The compressor should be allowed ample loading time.
Integrated Dryer Operation
In the default mode, the dryer is non-cycling. The stop button must be
pressed to shut-o the dryer.
In the energy e cient mode, the dryer may run up to 6 minutes before
it shuts o automatically during the Start/Stop mode of the compressor
package. Note the dryer could be o for an extended period if the
compressor needs to come back on right away.
NOTICE
If ISO Class 4 dew point standards are critical to your application,
run the compressor in unload mode ( xed speed) or idle mode
(variable speed) for one minute at startup to allow the dryer to reach
the required dew point before the compressor begins providing
compressed air.
93014.15.06
80447162 Rev B EN-11
EN
OPERATING INSTRUCTIONS FOR VARIABLE SPEED DRIVE (VSD)
Basic Operation
NOTICE
The language and compressors of measure displayed on the controller
will be preset before leaving the factory. If these are required to be
changed, contact your local Ingersoll Rand service provider.
Prior to starting
Check that the coolant level is at least visible in the center of the sight glass
and add coolant if necessary. Refer to the maintenance procedures for setting
the correct level.
Ensure that the discharge air isolation valve is open. Switch ON the main
electrical isolation switch. The control panel will illuminate, indicating that
the line and control voltages are available.
The contrast of the SG controller display may be adjusted by turning the
small screw which is on the right hand side of the controller when accessed
through the starter cabinet door.
Initial check sequence
The controller will perform an initial check sequence if the compressor
receives initial power to the controller or has experienced an trip reset. While
the initial check sequence occurs, the controller will display a “Checking
Machine” message.
During the initial check sequence, the controller will check the control system
for proper operation. During this time, if any items are found inoperative, a
trip will occur and the compressor will not start.
After completion of the initial check sequence, the controller will then display
“READY TO START’. This process should be completed within 10 seconds.
Start sequence
The compressor will initially start by the operator pressing the local start
button or receiving a remote start command. The compressor will start
loaded and will ramp up the motor speed to its minimum speed. Once the
minimum speed has been achieved, the compressor will begin to control
pressure by using its speed regulation. When the system pressure reaches
the target pressure, the compressor will start to slow. If the system pressure
rises to the immediate stop pressure setpoint the compressor will stop. If
the system pressure rises to the auto stop setpoint and the compressor is at
minimum speed, the compressor will stop.
NOTICE
During the  rst startup of the compressor, check for the proper
direction of rotation of the dryer condenser fan. If the fan is not
rotating in the direction indicated by the rotation arrow decal, reverse
two of the wires at the main power supply or at the contactor in the
package starter box. Perform the proper stop sequence and lockout/
tagout the main electrical supply before making changes to the
wiring.
Stop sequence
The compressor can be stopped by a local or remote stop, a shutdown due
to a trip, or an emergency stop. All of the above conditions will cause the
compressor to stop immediately, except the local or remote stop. A local or
remote stop will open the blowdown valve and the compressor will run for
up to 10 seconds or until the pressure in the separator tank falls to 2.4 bar
(35 psi) before stopping. The compressor will stop if the system pressure
reaches the automatic stop or immediate stop pressure setpoints. However,
if the compressor stops for this reason, it will automatically restart when the
system pressure falls below the target pressure.
NOTICE
If the compressor has to be stopped in an emergency depress the
emergency stop button located underneath the instrument panel.
Warm up mode
A warm up cycle occurs when the compressor’s airend discharge temperature
doesn’t reach the required warm up temperature (82°C/180°F) for two
consecutive operational cycles. On a warm up cycle, instead of stopping,
the compressor will continue to run with the blowdown valve open.
The compressor will run in a  xed speed mode, at minimum speed. The
blower will operate at minimum speed. The compressor will run like this
for approximately  ve minutes. During a warm up cycle, the controller will
display the message Warm Up Mode. If the pressure falls during this time
period, the compressor will return to normal operation.
Blower control
The blower speed varies in some conditions to assist in controlling the after-
cooler approach temperature and the coolant injection temperature. The
blower motor has its own variable speed drive and will ramp up and down as
the compressor starts and stops.
Emergency stopping
If the compressor has to be stopped in an emergency press the emergency
stop button located underneath the instrument panel.
This will over-ride the normal unload/stop button and will immediately stop
the compressor.
NOTICE
It is a normal situation that drive cooling fan continues to run even
when the drive is stopped. And the fan can run even under an E-stop.
Restarting after emergency stopping
If the compressor has been switched OFF because of a compressor
malfunction, identify and correct the fault before attempting to restart.
If the compressor has been switched OFF for reasons of safety, ensure that
the compressor can be operated safely before restarting.
Refer to the PRIOR TO STARTING and START SEQUENCE instructions earlier in
this section before restarting the compressor.
93014.15.06
EN
EN-12 80447162 Rev B
OPERATING INSTRUCTIONS (XE-90M CONTROLLER)
User Interface
The standard user interface con guration of the controller consists of the
membrane and the LCD display. The membrane consists of  ve command
keys (START, STOP, LOAD, UNLOAD, and RESET), four navigation keys (UP,
RIGHT, LEFT and DOWN), and an Edit mode selection key (ENTER). These keys,
the color graphics display and the LED icons make up the user interface to
the compressor.
Figure 7 : Xe-90M
LED status icons
Three LED icons are used to indicate the current status of the control system
from a distance and are located on the upper left side of the user interface.
Table 4 : LED Status Icons
Icon Name Function
OK
Illuminates when no Warnings or Trips are sensed.
Can be in a Ready or Not Ready state.
Alert
Illuminates when an Warning ( ashes) or Trip
(constant ON) is sensed. Can be in a Ready
(Warning) or Not Ready (Trip) state.
Auto
Illuminates when the compressor stops in auto
restart.
Command keys
These keys command the controller to perform actions as speci ed in the
following table. When any of these keys are pressed the action below will be
initiated and logged in the event log.
Table 5 : Command Keys
Icon Name Function
--- None
Load
Puts the compressor into the selected mode of
operation. Unit will load if the pressure conditions
are right.
Unload
Puts the compressor into an unloaded state. Unit
will run unloaded.
Reset
Clears Warnings and Trips once the condition is
corrected.
Icon Name Function
Start Starts the compressor.
Stop
Stops the compressor. This button should be
pressed instead of the E-Stop for normal stopping
operation.
Enter
Toggles the display between the Navigation mode
and the Edit mode.
NOTICE
The LOAD and UNLOAD keys are not used on variable speed
compressors.
Navigation keys
There are four navigation keys (UP, RIGHT, DOWN and LEFT). While the ENTER
key is not considered a navigation key, it is used in conjunction with the
navigation keys to make or con rm a selection.
Figure 8 : Navigation Keys
Pressing one of the navigation keys will lead the user down a navigation path.
Each time the key is pressed, another step in the path is taken. Once the end
of a navigation path is reached, pressing the key one more time will bring the
user back to the beginning of the path. Pressing the opposite key, will move
the user through the navigation path in the opposite direction. Once the
beginning is reached, pressing the opposite key will take the user to the end
of the path.
Display layout
Figure 9 : Display Layout
Table 6 : Display Layout
Key Name Description
A Folder Bar Uses tabs to graphically identify each folder.
B Title Bar Identi es current folder and page (underlined).
C Page Content Content of the current page.
D Dashboard Displays system status.
93014.15.06
80447162 Rev B EN-13
EN
Folder navigation and icons
To move among the tabbed folders shown on the LCD display, press the
RIGHT and LEFT keys. The navigation rolls over from the last to the  rst folder
and vice-versa.
Table 7 : Folder Bar Icons
Folder
Name
Icon Description
Home
System performance and status main
information. The  rst page of this folder is the
default page when the controller  rst powers up.
Operator
Settings
System options and con guration settings.
Events
System events log.
Trip History
Details on the most recent trips.
Graphing
On-board graphing of system data. (Optional for
some controllers)
Maintenance
Status and noti cation setup for compressor
maintenance items.
General
Settings
General settings such as Language, Time, and
Units of Measure.
Integral
Sequencing
Inter Module communication status and
con guration.
Status
Measurements or status from/of all analog and
digital I/O.
Factory
Settings
Compressor tuning parameters. Also displays
hardware and software versions.
Page navigation
Once the desired folder is selected, press the DOWN key to move to the page
selection area and then use the RIGHT and LEFT keys to select the desired
page. Use the UP key to get back to the folder tabs.
Table 8 : Title Bar Page Icons
Icon Description
Start of the page selection area.
Indicates that there are more pages available by navigating
right.
Indicates that there are more pages available by navigating
left.
Accessing parameters
After the desired page is selected, the pages parameters can be selected by
using the DOWN key. The cursor will move to the next parameter each time
the DOWN key is pressed. Use the UP key to go back to the previous one.
The cursor rolls over, so once the last parameter is selected, pressing the
DOWN key will navigate the cursor to the folder bar. If the  rst parameter is
selected, pressing the UP key will move the cursor to the page selection area.
Once selected, access parameters by pressing the ENTER key. Make changes
using the navigation keys and then enter the setting by pressing the ENTER
key again. After a parameter is accessed, pressing the ENTER key will enter
the current setting into the control program and navigate the cursor back to
the selected parameter on the page.
When the cursor is on a parameter that has an enabled/disabled box,
pressing the ENTER key will cause the setting to toggle.
This “X” icon appears on numeric entry windows as shown below. Placing the
cursor on it and then pressing the ENTER key will cancel the entry and any
changes that were made.
Figure 10 : Numeric Entry Window
NOTICE
Not all pages have adjustable parameters. Some just have read-only
information.
Dashboard icons
The dashboard is intended to be a quick at-a-glance view of system status.
The following table lists standard dashboard icons and their de nition.
Note that the color of these icons changes based on the state set by the
application while running.
Table 9 : Dashboard Icons
Name Icon Description
Network
Control
Network control is enabled.
Service
Required
A service reminder is nearing or has expired
(i.e.: an air or oil  lter needs to be changed).
Unloaded
or
Loaded
Compressor is in the unloaded state.
Compressor is in the loaded state.
Folder Options (Fixed Speed)
Home folder
Page 1: System Overview
Figure 11 : Home Folder
This is the factory default display after powering up the system.
Online Pressure Setpoint is indicated in the white box and by the white
arrow, which is always left of center on the gauge.
O ine Pressure Setpoint is indicated in the white box and by the white
arrow, which is always right of center on the gauge.
Package Discharge Pressure is indicated by the large numbers centered
below the gauge and by the red arrow.
Pressure Unit of Measure is indicated below the Package Discharge
Pressure. This is selectable from the General Settings folder.
Airend Discharge Temperature is indicated by the numbers in the lower
left of the display.
Temperature Unit of Measure is indicated to the right of the Airend
Discharge Temperature. This is selectable from the General Settings folder.
93014.15.06
EN
EN-14 80447162 Rev B
Run Hours indicate the number of hours the compressor has been
running.
NOTICE
The online and o ine set points can be selected and modi ed on this
page. All other information on this page is read only.
Page 2 : Counters
Figure 12 : Counters
Hour Meters indicate the hours that: the controller has been powered
up, the compressor has been running, and the compressor has running
loaded.
Starts indicate the number of times a start is attempted on the
compressor.
Date & Time is adjustable and con gurable in the General Settings folder.
Pages 3-4: Analog Inputs
Figure 13 : Analog Inputs
Icon Meaning
Pressure
Temperature
NOTICE
All information on these pages is read only.
The following inputs are displayed in this section:
Package Discharge Pressure
Sump Pressure
Airend Discharge Temperature
Injected Coolant Temperature
After-cooler Discharge Temperature
Separator Pressure Drop
Coolant Filter Pressure Drop
Inlet Vacuum
After-cooler Discharge Pressure (integrated dryer compressors only)
Remote Pressure (optional)
Operator settings folder
Pages 1-2: Operator Settings
Figure 14 : Operator Settings
Table 10 : Operator Settings
Operator
Settings
Selection Min. Max. Default Step Unit
O ine
Pressure
--- 75 Rated+10 Rated+10 1 psi
Online
Pressure
--- 65 O ine-10 O ine-10 1 psi
Lead/Lag Lead/Lag --- --- Lead --- ---
Lag O set --- 0 45 0 1 psi
Mode of
Operation
Mode --- --- ON/OFF
line
--- ---
Condensate
Release
--- 2 20 5 1 sec
Condensate
Interval
--- 90 270 180 1 sec
Stop Delay
Time
--- 10 30 10 1 sec
Star-Delta
Time / Start
Time
--- 5 30 10 1 sec
Pages 3-5: Operator Options
Figure 15 : Operator Options
93014.15.06
80447162 Rev B EN-15
EN
Table 11 : Operator Options
Operator Options Selection Min. Max. Def. Step Unit Installed option
required?
Enable Auto Restart ON/OFF --- --- OFF --- --- No
Auto Restart Time --- 2 60 10 1 Min No
Auto Restart Delay --- 0 60 0 1 Sec No
Comm Control ON/OFF --- --- OFF --- --- No
Remote Start/Stop ON/OFF --- --- OFF --- --- No
Power Out Restart ON/OFF --- --- OFF --- --- Yes
Power Out Restart Time --- 10 600 10 1 Sec Yes
Low Ambient Temp* --- 30 60 35 1 Deg F No
Lead/Lag Cycle Time** --- 0 750 0 1 Hours No
Scheduled Start - Day --- Day Day Sun 1 Day Yes
Scheduled Start --- 00:00 23:59 00:00 1 Time Yes
Scheduled Stop - Day --- Day Day Sun 1 Day Yes
Scheduled Stop --- 00:00 23:59 00:00 1 Time Yes
High Dust Filter ON/OFF --- --- OFF --- --- Yes
Remote Sensor ON/OFF --- --- OFF --- --- Yes
* The low ambient temperature is only adjustable if the low ambient factory set point is on.
** A value of 0 will disable the lead/lag cycle time feature.
Pages 6-7: Sensor Calibration
Figure 16 : Sensor Calibration
Sensor calibration can only take place when the compressor is stopped.
There should be no pressure on a sensor when it is calibrated. Calibration
only needs to take place after a sensor is replaced, the controller is replaced,
or the operator suspects the sensor reading is in error. Calibrate a sensor by
selecting the checkbox beside the sensor name.
Each of the sensors listed below can be calibrated:
Inlet Vacuum (1AVPT)
Sump Pressure (3APT)
Package Discharge Pressure (4APT)
Coolant Filter Inlet Pressure (5CPT)
Coolant Filter Outlet Pressure (6CPT)
Remote Pressure (10APT) – Only on compressors with the remote sensor
option
Interstage Pressure (2APT) – Only on 2-stage compressors
After-cooler Discharge Pressure (7APT) – Only on compressors with
integrated dryer
Please note that if a sensor is currently reading a value that is +/- 10% of
its range from zero, the sensor will not be able to be calibrated. Please
make sure the sensor is being exposed to atmosphere before attempting
calibration.
Events folder
Pages 1-42 (max.)
Figure 17 : Events Folder
The pages in the Events folder document up to the last 250 events that the
controller has experienced, and time stamps each. The events are recorded
in sequence, with number one being the newest and 250 being the oldest.
When a new event occurs, it becomes number one and all others are shifted
up in number.
The page numbers in the Title Bar are used to scroll through the events, with
each page displaying up to seven. Page one displays events one through six,
page two displays seven through twelve, and so on.
The following items will generate an event:
Power ON
Power OFF
Press the Start Key
Press the Stop Key
Press the Load Key
Press the Unload Key
Warning
Trip
Start Inhibit
Active Warnings will be highlighted in amber while cleared Warnings will
have amber text.
93014.15.06
EN
EN-16 80447162 Rev B
Active Trips will be highlighted in red while cleared Trips will have red text.
Active Start Inhibits will be listed in the Event log, but not highlighted. The
display will indicate the compressor is not ready to start if a start inhibit is
active.
See the following lists for details about messages in each type of event.
Warning Events List
Change Inlet Filter
Will occur if 1AVPT is greater than 0.7 psi vacuum (or 1.3 psi vacuum if the
high dust  lter option is enabled) and the compressor has been loaded for at
least 8 seconds. This condition must exist for 3 seconds before the warning
is issued.
Change Coolant Filter
This will occur if the compressor has been running loaded for at least 8
seconds, is warmed up, and the coolant  lter pressure drop (5CPT - 6CPT)
is greater than 25 psi. This condition must exist for 3 seconds before the
warning is issued.
Sensor Failure
This will occur whenever sensors 4ATT, 5DTT, 6DTT, and 7APT are recognized
as missing or broken. The sensor failure message shall follow the following
format: SENSOR FAILURE 4ATT. The 5DTT, 6DTT, and 7APT sensor failures will
be shown only when the integrated dryer is installed (accessed in the factory
settings menu). This condition must exist for 3 seconds before the warning
is issued.
Change Separator Element
Will occur if the compressor is loaded, the compressor is warmed up (the
injected coolant temperature is at least 120 °F), the package discharge
pressure is at least 90 psi, and the separator pressure drop is greater than
12 psi. This condition must exist for 3 seconds before the warning is issued.
High Airend Discharge Temperature
Will occur if the compressor is running and 2ATT is greater than 221 °F (97%
of 228) and the compressor is running. This condition must exist for
3 seconds before the warning is issued.
High Sump Pressure
If the compressor is running loaded, has been loaded for at least 8 seconds
and the sump pressure is more than 25 psi above the rated pressure for the
compressor. If this warning occurs, the online and o ine pressures will be
reduced. For example, a rated pressure of 100 psi would have a maximum
o ine pressure of 110 psi. This warning would occur if the sump pressure
goes above 125 psi in this example. This condition must exist for 3 seconds
before the warning is issued.
Auxiliary 1
This will occur if auxiliary input 1 closes. The contact must be closed for at
least 3 seconds before the warning will occur.
Auxiliary 2
This will occur if auxiliary input 2 closes. The contact must be closed for at
least 3 seconds before the warning will occur.
Service
Service warnings occur when the compressor has operated a certain number
of hours, based on the total hours. Service warnings can have multiple
levels, depending on the service level selection. A service level selection of 0
disables service warnings.
Service Level 1
If service level 1 has been selected for the compressor, a “SERVICE REQUIRED”
warning will be issued on hour intervals equal to the service time period set
point. This warning can be reset the same as any other warning.
Service Level 2
If service level 2 has been selected for the compressor, the service complete
factory set point will be used to clear a level 2 service warning and reset
the service time or date. The service complete can be reset before a service
warning occurs.
The initial “SERVICE REQUIRED” warning will occur at total hour intervals
equal to the service time period set point. However, 100 hours before this
a “100 HOURS TO SERVICE” warning will occur. This warning can be reset
the same as any other warning. One hundred hours later the “SERVICE
REQUIRED” warning will occur. This warning can be reset the same as any
other warning, however this warning will return in 24 hours if the service
complete factory set point has not be set. If the service complete has not
been set, 100 hours later, the ALARM – SERVICE REQUIRED” warning will be
issued. This warning can only be cleared by the service complete factory
set point. Once the service complete factory set point is set, indicating the
service is completed, the time for the next “SERVICE REQUIRED” warning will
be calculated by adding the service time period to the total hours value, with
the “100 HOURS TO SERVICE” warning occurring 100 hours before and the
ALARM – SERVICE REQUIRED warning occurring 100 hours after that time.
Communication Failure
This will occur if the compressor is the lead compressor in integral
sequencing and is unable to communicate with another compressor.
Sensor Failure 10APT – Remote Sensor
This will occur if the remote sensor option is ON and the remote sensor
is recognized as missing or broken. If this occurs, the compressor will
automatically start using 4APT for loading and unloading the compressor.
Units equipped with an integrated dryer cannot have a remote pressure
sensor. This condition must exist for 3 seconds before the warning is issued.
High Discharge Pressure
Will occur if the compressor is using a remote sensor or is under the control
of an external device, such as an 8XI, is loaded, and the discharge pressure
(4APT) is greater than the maximum o ine pressure. This condition must
exist for 3 seconds before the warning is issued. If this condition occurs, the
compressor will automatically unload. The compressor will be available to
reload once the discharge pressure falls to the rated pressure value.
Condensate Drain Error
This will occur if the compressor is running, the package discharge pressure is
over 50 psi, and the condensate drain error contact closes for at least
240 seconds. This warning will be ignored for 4.5 minutes after starting.
Freeze Warning
This will occur if the evaporator sensor has a value of 687 (about 0.5 C)
or below (low temp) while the dryer is running, on compressors with the
integrated dryer. This is a dryer fault. If this happens, the compressor will
continue to run, but the dryer will stop. The condition must exist for at least
180 seconds before the warning will occur. NOTE: If this warning is reset
while the conditions for running the dryer exist, the dryer can restart. Also the
dryer can restart if the evaporator value rises to 709 (about 5 C). However the
warning will still be displayed.
Dryer High Pressure
On compressors with the integrated dryer, this will occur if the dryer high
pressure switch opens while the dryer is running. This is a dryer fault. If this
happens, the compressor will continue to run, but the dryer will stop. The
contact must be open for at least 3 seconds before the warning will occur.
If this warning is reset while the conditions for running the dryer exist, the
dryer can restart. However, this switch is a locking switch. The switch must be
reset before the dryer can run. Resetting the warning on the display does not
reset the switch.
Condenser Temperature High
This will occur if the condenser sensor has a value above high temperature
threshold while the dryer is running, on compressors with the integrated
dryer. This is not a dryer fault. If this happens, the compressor and dryer will
continue to run. The condition must exist for at least 180 seconds before the
warning will occur.
Condenser Temperature Low
This will occur if the condenser sensor has a value below the low temperature
threshold while the dryer is running, on compressors with the integrated
dryer. This is not a dryer fault. If this happens, the compressor and dryer will
continue to run. The condition must exist for at least 180 seconds before the
warning will occur.
Change HE Filter
The HE  lter is located between the after-cooler discharge and the inlet to
the dryer and is only on compressors with an integrated dryer. The drop
93014.15.06
80447162 Rev B EN-17
EN
across the HE  lter is measured by subtracting the package discharge
pressure from the after-cooler discharge pressure. If the compressor is
running, the measured drop across the HE  lter is at or above 10 psi (0.7
bar), the compressor is hot (injected coolant temp above 120 °F), and the
package discharge pressure (4APT) is above 90 psi, this warning can occur.
The condition must exist for at least 3 seconds before the warning will occur.
This is not a dryer fault. If this happens, the warning will be displayed, but the
dryer will continue to run.
Trip Events List
Low Sump Pressure
Will occur if the compressor is running unloaded or loaded and 3APT is less
than 13 psi for 15 seconds.
High Airend Discharge Temperature
This will occur if 2ATT is greater than 228 °F and the compressor is running.
Check Motor Rotation
This will occur if 3APT is less than 1 psi on a compressor, 3 seconds after
starting (6 seconds if the compressor is equipped with a soft starter or airend
discharge temperature is less than 50 °F). This condition can be caused by
the motor running in reverse. Once correct motor rotation is established, this
trip will not be checked again unless power is removed from the controller.
Main Motor Overload
This will occur if the motor overload relay contact opens. The contact must
be open for at least 3 seconds before the trip will occur.
Fan Motor Overload
Will occur if a fan motor overload relay contact opens. The contact must be
open for at least 3 seconds before the trip will occur.
Remote Stop Failure
Will occur if the remote start/stop option is enabled, the remote stop button
remains open and either start button is pressed.
Remote Start Failure
Will occur if the remote start/stop option is enabled, the compressor is
started by the remote start button, and the button stays closed for 7 seconds
after the compressor starts.
Sensor Failure
This will occur when a sensor is recognized as missing or broken. The sensors
a ected by this trip are 1AVPT, 3APT, 4APT, 5CPT, 6CPT, 2APT (if 2 stage
compressor), 2CTT, and 2ATT. The sensor should be displayed along with the
sensor failure message. The sensor failure message shall follow the following
format: SENSOR FAILURE 1AVPT.
Emergency Stop
This will occur when the emergency stop button is engaged.
High Sump Pressure
This will occur if the compressor is running loaded for at least 8 seconds, and
any one of the 3 following conditions exist. (1) The sump pressure is above
the rated pressure by 35 psi. (2) The separator pressure drop is measured to
be more than 25 psi and the package discharge pressure at least equal to the
minimum online set point value. (3) The sump pressure is above 165 psi if the
rated pressure is less than 190 psi or the sump pressure is above 220 if the
rated pressure is 190 psi.
High Coolant Filter Pressure Drop
This will occur if the compressor has been running loaded for at least 8
seconds, is warmed up, already has a change coolant  lter warning, and the
coolant  lter pressure drop (5CPT - 6CPT) is greater than 35 psi.
High Inlet Vacuum
This will occur if the compressor is running loaded and the inlet vacuum is
greater than 1.8 psi. If the compressor has a high dust  lter, the trip threshold
for inlet vacuum is 2.4 psi.
Unit Too Cold To Start
This will occur if the compressor does not have the low ambient option,
the airend discharge temperature (2ATT) is less than 35 °F, and the operator
attempts to start the compressor. This fault can only occur once a day. Once
this fault occurs, the operator can reset it and start the compressor. This fault
will be logged in the trip history to indicate that the compressor is being
started in low ambient conditions.
High Interstage Pressure
This will occur if the compressor is running and the interstage pressure
(2APT) is greater than 75 psi. This trip will only occur in 2 stage compressors.
Invalid Calibration
Will occur if the sensor zero value is +/- 10% of its scale. This will only occur
when a sensor is calibrated.
Start Inhibit List
High Airend Discharge Temperature
This will occur if 2ATT is greater than 95% of 228 °F.
High Sump Pressure
This will occur if the sump pressure (3APT) is 25 psi or higher than the rated
pressure of the compressor.
Trip history
Pages 1-4 (max.)
Figure 18 : Trip History
The pages in the Trip History folder document up to the last 15 trips that the
controller has experienced, and time stamps each. The trips are recorded in
sequence, with number one being the newest and 15 being the oldest. When
a new trip occurs, it becomes number one and all others are shifted up in
number.
The page numbers in the Title Bar are used to scroll through the events, with
each page displaying up to seven. Page one displays events one through  ve,
page two displays six through ten, and so on.
The following items will generate an event.
Power ON
Power OFF
Press the Start Key
Press the Stop Key
Press the Load Key
Press the Unload Key
Warning
Trip
Start Inhibit
Active Trips will be highlighted in red while cleared Trips will have red text.
The trip history also records compressor data at the time of the trip to assist
in diagnostics and troubleshooting. Navigating to the trip entry and hitting
the enter button will bring up the trip history dialog box.
93014.15.06
EN
EN-18 80447162 Rev B
Figure 19 : Trip History Dialog
While the dialog box is active, press the left and right keys in order to scroll
through the displayed data. The name of the trip will always be shown in
the title bar of the dialog box. Press enter when  nished viewing the data to
return to the trip history screen.
Maintenance folder
Page 1: Filter Status
Figure 20 : Filter Status
This page displays the following:
Coolant Filter Status
Separator Element Status
Inlet Filter Status
Page 2: Maintenance Status
Figure 21 : Maintenance Status
This page displays the time until the compressor should be serviced.
Page 3: Maintenance Con guration
Figure 22 : Maintenance Con guration
This page allows the user to set the service interval and to reset the counter
after the service has been performed.
General settings folder
NOTICE
All parameters in this folder are adjustable.
Page 1: Language Selection
Figure 23 : Language Selection
Language is selectable from the following 30 choices:
English (default) Korean
Bulgarian Latvian
Chinese, simpli ed Lithuanian
Croatian Maltese
Czech Norwegian
Danish Polish
Dutch Portuguese
Estonian Romanian
Finish Russian
French Slovak
German Slovenian
Greek Spanish
Hungarian Swedish
Italian Thai
Indonesian•Turkish
93014.15.06
80447162 Rev B EN-19
EN
The controller will display all screens in the selected language and only one
language can be selected at a time.
Each language appears in its native translation.
Page 1: Units of Measure Settings
Figure 24 : Units of Measure Settings
The following compressors of measure settings are displayed in this section.
Table 12 : Units of Measure Settings
Display Text Description
Temperature Selectable between °F and °C.
Pressure Selectable among psi, kpa, bar, kg/cm.
Power Selectable between kW and HP.
Page 3: Home Page Selection
Figure 25 : Home Page Selection
Table 13 : Home Page Selection
Display Text Description
Auto Return to
Home
Enables the controller to return the display back to the
selected Home Page if there is no user activity for the
Delay Time shown. This is only enabled when an “x
appears in the checkbox.
Delay Time Determines how many seconds of inactivity it will take
before the controller will return to the Home Page.
Select Home
Folder
Used to select the Home folder.
Select Home
Page
Used to select the Home Page within the selected Home
folder.
Pages 4-5: Time & Date Settings
Figure 26 : Time & Date Settings
All items are adjustable.
The following settings are displayed in this section:
Table 14 : Time & Date Settings
Display Text Description
Hours Allows the current hour to be set. The hours format is
xed on 24-hour.
Minutes Allows current minutes to be set.
Seconds Allows current seconds to be set.
Year Allows current year to be set.
Month Allows current month to be set.
Day Allows current day to be set.
Date Format Selectable between dd/mm/yyyy (default) and mm/dd/
yyyy.
Con rm New
Time and Date
Used to verify that changes to selections are desired. An
“x” must appear in the checkbox before any changes will
take a ect.
The controller will continue to display any changes, even when the selections
have not been con rmed and the user exits the page, then returns. Cycling of
the power returns all selections to their current settings.
NOTICE
The controller does not support Daylight Savings Time.
Page 6: Backlight Settings
Figure 27 : Backlight Settings
The following settings are displayed in this section:
93014.15.06
EN
EN-20 80447162 Rev B
Table 15 : Backlight Settings
Display Text Description
Backlight
Brightness
Adjusts the brightness of the display.
Enable Backlight
Auto-O
Enables the controller to shut-o the backlight if
there is no user activity for the delay time shown.
Backlight Auto-O
Delay Time
Determines how many seconds of inactivity it will
take before the controller will shut-o the backlight.
NOTICE
The backlight will be switched ON whenever any of the controller’s
keys are pressed.
The START, STOP, LOAD, UNLOAD, RESET, and ACKNOWLEDGE keys on
the controller remain functional while the backlight is switched OFF. It
is recommended to press the ENTER key or one of the navigation keys
in order to switch the backlight ON.
Pages 7-8: Ethernet Settings
Figure 28 : Ethernet Settings
Table 16 : Ethernet Settings
Display Text Description
Enable Ethernet Allow connection by users to utilize the
network enabled functionality of the controller
Enable DHCP Allow the controller to automatically receive an
IP address from the Local Area Network (LAN)
IP Address Setting When DHCP is not enabled, this setpoint sets
the IP address of the controller.
IP Address Actual This will match the IP address setting when
DHCP is not enabled. If DHCP is enabled
this will display the address assigned to the
controller by the DHCP server.
MAC Address This is the unique hardware MAC address for
the controller. This can not be changed.
Subnet Mask Setting Setpoint for the subnet mask
Subnet Mask Actual Current reading/setting for the subnet mask
Default Gateway Setting Setpoint for the default gateway.
Default Gateway Actual Current reading/setting for the default gateway.
Accept After editing the desired setpoint navigate
to the accept setting and press enter in order
for the values in the setting variables to be
con rmed by the controller.
Cancel Discard any changes made to the Ethernet
settings.
Status folder
NOTICE
All information on these pages is read only.
Pages 1-3: Analog Inputs
Figure 29 : Analog Inputs
The following inputs are displayed in this section:
Package Discharge Pressure
Sump Pressure
Airend Discharge Temperature
Injected Coolant Temperature
After-cooler Discharge Temperature
Separator Pressure Drop
Coolant Filter Pressure Drop
Inlet Vacuum
After-cooler Discharge Pressure (integrated dryer compressors only)
Remote Pressure (optional)
Coolant Filter Inlet Pressure
Coolant Filter Outlet Pressure
Interstage Pressure (2-stage compressors only)
Evaporator
Condenser
Page 4: Compressor Data
Figure 30 : Compressor Data
The following data are displayed in this section:
Power ON Hours
Running Hours
Loaded Hours
Real Time Clock
93014.15.06
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276