Digital Monitoring Products 265HCAN Cellular Communicator Guide d'installation

Catégorie
Amplificateurs de signal cellulaire
Taper
Guide d'installation
DESCRIPTION
Figure 1: 265HCAN Cellular
Communicator
1INSTALL THE 265HCAN
1. Touch grounded metal to discharge static
before handling the XTLplus.
2. Place the external antenna onto the SMA
connector, then twist the antenna until it is
securely tightened on the 265HCAN.
3. Insert the SIM card into the SIM card holder.
Slide the 265HCAN into the XTLplus
eight-pin CELL MODULE connector, keeping
the 265HCAN parallel to the XTLplus.
4. Align the stando hole in the 265HCAN with
the stando on the XTLplus and snap it into
place. See Figure 2.
The 265HCAN Cellular
Communicator provides
a fully supervised alarm
communication path over the
HSPA+ network.
The 265HCAN is installed on
the XTLplus and powered by
the panel so no additional
enclosure, power supply, or
battery back-up is needed.
Compatibility
All DMP XTLplus Series panels
with Version 171 or higher. See
the last page for compatibility
details.
Figure 2: Install the 265HCAN on the XTLplus
2ACTIVATE THE 265HCAN
Cellular service is required before you can use the
265HCAN for signal transmission. The 265HCAN
comes ready for activation with SecureComTM
Wireless, LLC. Cellular activation can by done
through Remote LinkTM, the Dealer Admin site
(dealeradmin.securecomwireless.com), the Tech
APPTM, or by calling DMP Customer Service
(1-866-266-2826).
What is Included
265HCAN Cellular
Communicator
External Antenna
Canadian 4G Nano SIM
Card
RESETLOAD
BAT
PROG
R B
+ DC -
S
N
Antenna
SMA
Connector
Eight-Pin CELL MODULE
Connector
Stando
Hole
SIM Card
Holder
265HCAN CELLULAR
COMMUNICATOR
Installation Guide
2 265HCAN INSTALLATION GUIDE | DIGITAL MONITORING PRODUCTS
1. Navigate to the Dealer Admin site (dealeradmin.securecomwireless.com).
2. Click Customers in the right-side menu and select a customer.
3. Click Add System.
4. Enter a System Name.
5. Select XTLplus from the System Type drop-down menu.
6. Select either Cellular or EASYconnect + Cell Backup in the Connection Type field.
7. Enter the SIM number found on the 265HCAN label and click Get Status.
8. Enter the Account Number.
9. Select a Rate Plan and an SMS Package for the 265HCAN.
10. Click Activate Cellular Device.
3
REMOTE LINK ACTIVATION
TEST THE 265HCAN
DEALER ADMIN ACTIVATION
1. Navigate to Remote Link and select a control panel.
2. Select Program in the top menu and select Communications from the drop-down menu.
3. Select Cellular Network as the Communication Type and click Activate.
4. Enter the SIM number found on the 265HCAN label and click Activate.
5. Select a Rate Plan and a Text Plan for the 265HCAN.
6. Click Activate at the bottom of the window.
1. Navigate to the Tech APP.
2. Tap Find a Customer then search for a customer.
3. Tap Add a System.
4. Enter a System Name.
5. Scan or enter the Serial #.
6. Select XTLplus from the System Type drop-down menu.
7. Select either Cellular or EASYconnect + Cell Backup in the Connection Type field.
8. Enter the Account Number.
9. Enter the SIM Number found on the 265HCAN label then tap Get SIM Status.
10. Select a Rate Plan and an SMS Package for the 265HCAN.
11. Tap Activate Cellular Device.
TECH APP ACTIVATION
The panel provides a diagnostic function to test the communication integrity and cellular
signal strength of the 265HCAN to the nearest tower for the cellular carrier. To use the
diagnostic function, reset the panel, enter 2313 (DIAG), and press CMD.
Communication Status
This option tests the individual components of cellular or wireless network
communication.
1. Select CELL STATUS from the DIAGNOSTIC menu. Possible test results are
shown in Table 1.
2. Select YES to continue through the remaining component tests or select NO to
stop testing and return to CELL STATUS.
265HCAN INSTALLATION GUIDE | DIGITAL MONITORING PRODUCTS 3
Table 1: Communication Status Results
Cellular Strength
This option provides a way to test the cellular signal strength of the nearest tower for the
cellular carrier. Follow the steps below to test the cellular strength of the 265HCAN:
1. Select CELL SIGNAL from the DIAGNOSTIC menu then press a select key or
area.
2. SIGNAL: displays.
The numerical value of the cell signal strength is represented in -dBm. The bars
represent the signal strength of the 265HCAN and range from 0-7. Zero bars
indicate a weak signal and seven bars indicate a strong signal.
Confirmed Faulty
MODEM OPERATING NO MODEM FOUND
IDENTIFIED NO SIM CARD
TOWER DETECTED NO TOWER
REGISTERED NOT REGISTERED
CONNECT SUCCESS CONNECT ERROR
NOT ACTIVATED
CELL PATH GOOD NO ACK RECEIVED
Designed, engineered, and
manufactured in Springfield, Missouri
using U.S. and global components.
INTRUSION FIRE ACCESS NETWORKS
2500 North Partnership Boulevard
Springfield, Missouri 65803-8877
866-266-2826 | dmp.com
© 2018 Digital Monitoring Products, Inc.
LT-1727 18063
Specifications
Primary Power 12VDC
Current Draw
Standby 13mA
Alarm 13mA
Compatibility
XTL+ Version 171 or higher
XTL+Z Version 171 or higher
XTL+W Version 171 or higher
XTL+WZ Version 171 or higher
Certifications
Cellular FCC ID: RI7UE910N3
Cellular Industry Canada: 5131A-UE910N3
Accessories
XTL+-HSG-W Replacement Housing
FCC INFORMATION
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. this device must accept any interference received, including interference that may cause undesired operation.
The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm (7.874 in.) from
all persons. It must not be located or operated in conjunction with any other antenna or transmitter.
Changes or modifications made by the user and not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment o
and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit dierent from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
Industry Canada Information
This device complies with Industry Canada Licence-exempt RSS standard(s). Operation is subject to the following two
conditions:
1. This device may not cause interference, and
2. this device must accept any interference, including interference that may cause undesired operation of the
device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence.
L’exploitation est autorisée aux deux conditions suivantes:
1. l’appareil ne doit pas produire de brouillage, et
2. l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible
d’en compromettre le fonctionnement.
This system has been evaluated for RF Exposure per RSS-102 and is in compliance with the limits specified by Health
Canada Safety Code 6. The system must be installed at a minimum separation distance from the antenna to a general
bystander of 7.87 inches (20 cm) to maintain compliance with the General Population limits.
L’exposition aux radiofréquences de ce système a été évaluée selon la norme RSS-102 et est jugée conforme aux limites
établies par le Code de sécurité 6 de Santé Canada. Le système doit être installé à une distance minimale de 7.87 pouces
(20 cm) séparant l’antenne d’une personne présente en conformité avec les limites permises d’exposition du grand
public.
265HCAN CELLULAR
COMMUNICATOR
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Digital Monitoring Products 265HCAN Cellular Communicator Guide d'installation

Catégorie
Amplificateurs de signal cellulaire
Taper
Guide d'installation