14
:RUNLQJDQGFRQWUROSRVLWLRQ
The operator must stand in front of the machine and load the ingredients, programme the recipe, start the processing and
unload the processed product at the end of the recipe.
0DFKLQHWHFKQLFDOGDWD
Model VB 35 VB 60 VB 80
Net weight kg 170 200 250
Coolant gas (type) R448A
For water version (quantity) g 1300 1700 1800
)RUDLUYHUVLRQTXDQWLW\ J
Quantity of product that can be processed (min. - max.) L 3 to 7 4 to 8 7 to 11
Max ambient temperature °C (°F) +30 (+86)
Cylinder capacity L 14 23 28
:$7(5YHUVLRQPDFKLQH(coolant gas pressure) bar 14 14 14
"CONDENSATION" (coolant gas temperature) °C +32 (+89,6)
:$7(5YHUVLRQPDFKLQH(coolant gas pressure) bar 1.0 to 0.6
"EVAPORATION" (coolant gas temperature)
°C (°F) -30 to -36 (-22 to -32,8)
Mains water temperature
°C (°F) +18 to +20 (+64,4 to +68)
Infeed water pressure bar 1 to 7
:DWHUFRQVXPSWLRQ /PLQ 3 to 4 4 to 5 4 to 5
$,5YHUVLRQPDFKLQH(coolant gas pressure) bar 17.2 to 22
"CONDENSATION" (coolant gas temperature)
°C (°F) +40 to +50 (+104 to +122)
$,5YHUVLRQPDFKLQH(coolant gas pressure) bar 1.0 to 0.6
"EVAPORATION" (coolant gas temperature)
°C (°F) -30 to -36 (-22 to -32,8)
Model VB90 VB120 VB160
Net weight kg 290 362 382
Coolant gas (type) R448A
For water version (quantity system 1) g 1400 1600 1800
(quantity system 2) g 1400 1600 1800
Quantity of product processable (min. to max.) L 6 to 12 5 to 18 8 to 24
Max. ambient temperature °C (°F) +30 (+86)
Cylinder capacity L 30 45 53
:$7(5YHUVLRQPDFKLQH(coolant gas pressure) bar 14
"CONDENSATION" (refrigerant gas temperature)
°C (°F) +32 (+89,6)
:$7(5YHUVLRQPDFKLQH(coolant gas pressure) bar 1,0 to 0,6 1,0 to 0,6 1,0 ÷ 0,6
"EVAPORATION" (coolant gas temperature)
°C (°F) -30 to -36 (-22 to -32,8)
Mains water temperature
°C (°F) +18 to +20 (+64,4 to +68)
Infeed water pressure bar 1 to 7
:DWHUFRQVXPSWLRQIRUHDFKV\VWHP /PLQ 3 to 4 4 to 5 4 to 5