FlowXtreme FlowXtreme NE4489 Manuel utilisateur

Catégorie
Accessoires de piscine hors terre
Taper
Manuel utilisateur

Ce manuel convient également à

VER.1219
A
A
bove Ground P
o
o
ol Filte
r
r
& Pum
p
p
Manu
a
a
l
NE4487
NE4488
NE4489
1
CONGRATULATIONS!
YOU HAVE PURCHASED A HIGH QUALITY FlowXtreme FILTRATIONS
SYSTEM FOR YOUR ABOVE GROUND POOL. YOUR NEW FILTER
SYSTEM HAS BEEN MANUFACTURED AND TESTED TO OFFER MANY
YEARS OF TROUBLE FREE SERVICE.
IMPORTANT – READ THIS MANUAL CAREFULLY
A. Safety Warnings
Read all Warnings and Cautions noted below. Failure to do so could result in serious or fatal injury.
Prior to installation of this unit, carefully read and adhere to all CAUTION, ATTENTION, and ADVICE
notices located throughout this manual. Failure to comply with these instructions can cause serious injury,
death, or damage to the unit.
RISK OF SUCTION ENTRAPMENT HAZARD, WHICH, IF NOT AVOIDED CAN RESULT IN
SERIOUS INJURY OR DEATH. Do not block pump suction at the pump or in the pool as this can cause
severe injury or death.
Electrical wiring MUST be installed by trained professional and adhere to local code and regulations.
Avoid electric shock. DO NOT USE power extension cords.
Connect ONLY to a Ground-Fault Circuit Interrupter (GFCI) power outlet. Consult a qualified professional
electrician for safe and proper installation of a qualified electrical outlet.
Consult and follow all local and national codes related to swimming pools and their equipment.
Incorrectly installed equipment may fail, causing severe injuries or damage to the pump-filter system.
Never submerge the filter and/or pump in water.
Never place the pump or filter in your pool.
Trapped air in the pump-filter system may cause the TANK COVER to be blown off which can result in
death, serious injury, or damage to the pump-filter system. Ensure all air is out of system before operating.
Never change the 7 Position Multi-Port Valve while the system is operating. Doing this repeatedly will
damage internal components of the valve and not be covered under warranty.
ALWAYS unplug the system before changing positions on the control valve.
Install this product with sufficient safety margin from the pool to prevent children from using the system to
access the pool.
Never PLUG or UNPLUG this unit from an electrical source while standing in water.
NEVER service this unit with electrical power cord connected.
DO NOT operate the system while the pool is being used.
KEEP CHILDREN AWAY from all electrical equipment.
NEVER ALLOW CHILDREN TO OPERATE THIS EQUIPMENT.
The Pool Owner should always exercise caution and common sense when utilizing their swimming pool and
operating equipment.
2
B. General Information
This manual provides information relating to the installation, utilization and maintenance of our filtration system.
We recommend that you read this manual in its entirety and keep it for future reference,
The pump included with the filtration system is a horizontal, self-priming centrifugal pump. For the pump to
function correctly, the water temperature must not exceed 35℃/95℉. The materials used in the pump have
undergone stringent hydraulic testing and electrical inspections.
The filter tank included in the filtration system consists of high-grade polypropylene (PP). It is manufactured as a
single unit (absolutely corrosion resistant and resistant to commercially available swimming pool chemicals).
(Prerequisite: Compliance with the standard recommended specifications for the pH- and chlorine value). It is
equipped with a tank drainage system, pressure gauge. The filter tank comes ready to attach and is supplied with a
user-friendly 7 Position Multi-Port Valve attached to the tank cover, an approved filter pump with hair and lint
basket, and a plastic base for ready on- site mounting.
Read this manual carefully before installation. The filtration system and pump must be installed in accordance
with all federal and local codes and standards in effect for the area of installation.
We decline all responsibility for the consequences of failure to comply with the installation instructions. We
recommend that you comply with the power source instructions to avoid overloading the pump motor and/or
electric shock.
This filtration system is not intended for use by persons with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge.
Safety notes and information boxes should always be observed.
C. Safety Notes
Your filter pump was constructed and tested and left the manufacturing plant in technically operational condition.
In order to maintain this condition and ensure safe operation, the user should observe the notes and product
information contained in this technical manual. If there is any indication that safe operation is no longer possible,
the device is to be disconnected from the power supply and secured against accidental use.
This is the case when:
The device has visible damage.
The device no longer appears functional.
After long periods of storage in poor conditions.
If the power cord or other parts of this equipment are damaged, they have to be replaced by the manufacturer or its
service agent or a similarly qualified person in order to avoid danger.
D. Damage during delivery
Your filter system has been carefully and professionally packed for delivery. Please check to ensure that the
package is undamaged and that all parts are in the box (see the parts lists at the end of this manual). If you
purchased this product on order and the product was shipped to you, ensure that delivery is complete. Damage to
product as a result of shipping is not the responsibility of the supplier and must be immediately reported to the
shipper. The shipper assumes the liability for damages during delivery, the supplier is not responsible for it.
E. Implied Warranty
The manufacturer warranties safe operation and reliability only under the following conditions:
The filter system is installed and operated according to the assembly and operating instructions.
3
Only original replacement parts are used for repairs or replacements (consumable & expendable parts do no
fall under the warranty).
Expendable parts that do not fall under the warranty include:
All O-rings
Pressure gauge
Mechanical seal, complete
Hoses and metal hose clamps
F. Resultant Damages
We cannot be responsible for damages to the product if the product is not used in accordance with the instructions
provided.
G. Technical Data and Specifications
The recommended filter run time is twice a day for 4 to 5 hours; regular backwashing time is 2-3 minutes at
least once a week, and floor vacuum cleaning as needed are the basic pump requirement for maintaining
clean swimming pool water!
The major components for this model are: (Confirm you have all these components before starting
installation)
The Tank lid with 7-way valve, filter pump, filter tank, 1 1/4’’-1 1/2’ hose connectors and base plate.
NE4487 NE4488 NE4489
Flow rate: 2100 GPH 2300 GPH 5400 GPH
MAX Operating Pressure: 22 psi 22 psi 22 psi
Related Voltage: 110V AC 60Hz 110V AC 60Hz 110V AC 60Hz
Power 1/2HP 3/4 HP 1 HP
Amount of Sand: Max 35lbs Max 75lbs Max 100lbs
Pool size: Max 4,000 US gallons Max 8,000 US gallons Max 20,000 US gallons
H. Unpacking your filter system
Carefully remove the product and all component parts from the box. Cross reference all parts in the box with the
parts list reference chart to make certain all parts are present before beginning assembly.
NOTE: Some parts may be located within the filter tank. To access these parts, you must remove the tank cover.
Refer to *pages 10-15 for complete EXPLODED VIEW PARTS DIAGRAMS.
I. Power source instructions
1.The Above Ground filter pump system you have purchased is equipped with a standard electrical cord and
plug which should only be connected to a power outlet protected by a 30 Amp
Ground-Fault-Circuit-Interrupter (GFCI) that has been installed by a professional electrician and adheres to
local codes and regulations.
2. To avoid electric shock, power cord extensions should not be used.
J. Positioning your filter system
4
For the operation of this filter system with Above Ground pools, you need a skimmer installed in your
pool. Either an integrated skimmer (built into the pool wall) or a suspended floating skimmer (attachment
to the pool wall).
The installation area must allow an adequate safety margin to the pool wall. Refer to local and national
codes for required distance between the filter system and the pool wall.
We recommend putting the filter system on a concrete slab or similar. Be sure the
Installation site is level.
Additional installation accessories such as hoses, hoses clamps, and filter sand
(not included) are available from your pool dealer.
K. Filter-Pump Assembly (Figures 1-3)
1. Filter pump & Base Plate assembly
a. Secure water pump to the base plate with the provided pump mounting hardware. Orient as shown.
(Figure1)
b. Place the base plate and pump in the location where the Pump Filter System will be located for normal
operation and within reach of the pool filter and return hoses but with a sufficient safety margin from the edge
of the pool. Attach the filter tank to the base plate as shown. The feet on the bottom of the filter tank fit within
the holes provided on the base plate (Figure 3).
c. Filling sand chamber with sand (Figure 4-7)
Position the filter pump assembly to the location you have dedicated for its operation. NOTE: Do this
before you fill the chamber with sand as the unit will become heavy and difficult to move around.
Check to ensure that the bottom strainer is correctly positioned.
Check to ensure that the tank separator plate is seated properly.
Check to ensure that the upper distributor is located under the tank cover.
Fill the sand chamber half full with water.
Pour #20 Pool Filter Grade silica sand into the SAND FILTER CHAMBER being careful not to allow any
sand to enter the FILTERED WATER CHAMBER.
NOTE: Installation of sand other than #20 Pool Filter Sand will NOT function properly,
and may void your warranty.
d. Secure the lid/valve to the filter tank (Figure 8)
Ensure the main tank seal around the top of the filter tank is in good condition and securely seated in the
groove. Be sure groove is free of sand.
Carefully place the tank cover onto the filter tank. The tank cover should be oriented so that the notch on
the cover is aligned with the matching tab on the filter tank-this ensures proper alignment.
Secure tank cover and filter tank with the tank cover lock ring assembly and tighten with the knob and
bolt.
2. Pump hose connections (Figure 9-18)
a. Attach the 1¼ / 1½ hose connector & collar onto the intake port of the filter pump. Ensure that the
O-ring is installed between the port and the connector.
b. Skimmers: Connect hose from pool skimmer to the intake fitting on the filter pump. Secure with a hose
clamp.
c. Pressure line: Connect the flexible 1½” hose from the upper discharge point on the top of the filter pump to
the connector with designation “PUMP” on the 7-way valve. (Figures 13&18)
d. Return line: Connect a flexible hose (not included with your system) from the 7-way valve port with the
5
designation “RETURN” to the return fitting or connection for the pool location. Secure all connections
with hose clamps. (Figures 13 & 18)
If using flexible hose: Lightly lubricate the pool return port on the tank cover with petroleum jelly.
Secure with a hose clamp.
NOTE: Be careful not to secure return hose to the waste/backwash port.
e. Backwash: Connect to “WASTE” using backwash hoses and clamps. Backwash hose and clamps are
available from your local swimming pool retail professional.
f. Connecting the filter system
This Pool filter system is designed to connect to pools with standard 1½ diameter hose connectors. If your
pool has a hose connector size and/or type different than described here, you may need to purchase an adapter
at your local pool supply store or hardware retailer.
Before you begin to connect hoses to the filter and pump, make certain that no water can flow through the
intake or return hoses connected to the pool. Some pools have shut off valves in their intake and return ports,
others do not. If you do not have a shut off valve, block the ports with a removable plug to prevent water
from passing into and through the hoses.
These instructions assume that the pool is already assembled with hoses attached to the water intake and
return ports on the pool.
L. Filter system start up
WARNING Never rotate the valve handle while the pump is running. You will damage the Diverter
Gasket inside the 7-position multi-port valve. Damage to the Diverter Gasket will not be covered under
warranty.
It is important that you read and follow the instructions on proper power supply sources.
Once the filter system has been properly assembled, the tank filled with sand and the hoses connected as described,
you may begin filtration. However, we recommend that you first clean and prepare the new sand. Cleaning the
sand prior to filtering your pool will remove most of the dust and tiny sand particles that may exist in the sand. If
you move straight to filtering, these particles will end up in your pool. To clean the sand, please follow the
instructions below.
Do not turn on the system until advised to do so.
Note: Do not back wash on initial installation if filter media is Cotton Tails. Follow the use instructions
provided with Cotton Tails.
1. Make certain the pump is not plugged into a power supply.
2. Start with the multi-position valve in the 5 Closed position.
3. If you haven’t done so already, fill your pool with water. Ensure that the water level is at least 1”-2” above the
top of the hose intake (Skimmer) and return ports in the pool.
4. Release the shut off valve at the intake port (Skimmer) in the pool. If you plugged the intake port (Skimmer),
remove the plug to allow the water to flow into the intake hose. You may need to partially open one of the large
clear view port covers to act as an air relief valve to completely fill the tank with water.
5. With the filter-pump system installed in a location level lower than your pool’s water level-water will
automatically flow into the pump-filter system.
6. Allow the filter tank to fill with water.
7. Check for leaks and make any adjustments needed to stop leaks found. It may be necessary to use “Teflon” tape
wrapped around the hose fitting threads. Teflon Tape is available at pool or hardware stores if not included in your
filter package.
6
8. When you first fill your filter tank with sand it is necessary to clean the small particles and dust from the new
sand. If you do not do this you will blow this dust and small particles into your pool. To properly clean the new
sand follow the backwash process described below:
Turn off the Motor / Pump at the Power Source.
Attach backwash hose (not included) to backwash port. Available at a local pool store.
Place the Multi-Port Valve in the “4 – Backwash” position.
Turn on the Pump
Run filter in BACKWASH mode until discharge water is clear.
Turn off the Motor / Pump at the Power Source.
Place the Multi-Port Valve in the “2 – RINSE” position.
Turn on the Pump.
Allow filter to run for 60 seconds to remove any remaining sand or debris residue from pump and valve
plumbing.
Turn off the Pump at the Power Source.
Place the Multi-Port Valve in the “1 – Filtration” position.
Turn on the Pump.
Your filtration system is running and ready for further operation.
M. 7-Position Multi-Port Filter Valve Position Operation
Setting Complete water flow/function
Filter
Position 1
Picture 19
Function: Regular pool filter action & vacuuming. This is the setting the filter will be
set to most of the time. In this position, water is directed through the top of the filter
where it compresses and flattens down the sand. Contaminations are trapped by the
sand as water makes it way to the bottom strainer, out of the filter and back to the
pool.
Rinse
Position 2
Picture 20
Function: Use after backwashing to clean the filter bed. This should always be done
immediately after backwashing, new sand addition or filter start-up. In this position,
water is directed to the top of the tank where it flushes the valve while sending water
out the waste line.
Circulation
Position 3
Picture 21
Function: Circulate water after chemical treatment. This position is used during
certain pool cleanups and chemical treatments when you don’t want the water
contaminating the sand. In this position, water is only directed through the valve back
to the pool and does not filter through the sand.
Backwash
Position 4
Picture 22
Function: Clean filter of captured debris. This is the position needed to clean the filter
& the sand. You’ll know it is time to backwash when the pressure gauge shows more
than 10 PSI above what it normally reads when the filter is clean. In this position,
water is directed through the bottom strainer, reversing the flow through the tank.
This causes the sand to separate and lift while releasing trapped debris out the waste
port and backwash hose.
7
Closed
Position 5
Picture 23
Function: Cleaning the hair and lint strainer. This position stops the flow of water
into the pump and filter.
CAUTION: Do not run pump with valve in this position.
Purge/Drain
Position 6
Picture 24
Function: Bypass the filter. This position is ideal for vacuuming pools with large
amounts of debris or after an algae treatment. In this position, water bypassed the
filter and sends all the water and contaminates out the waste line.
Winterize
Position 7
Picture 25
Function: Winterizing and storage. In this position, the valve lever is between
positions which removes pressure from internal valve components for winter
(off-season) storage.
CAUTION: Do not run pump with valve in this position.
N. Manual Vacuuming the Pool
1. For Above Ground Pools
Vacuuming is done in valve position #1, Filter, on the valve. The pool vacuum is connected by use of a pool
vacuum hose and vacuum plate directly into the skimmer. Do not turn on the pump until the pool vacuum is
connected and ready for operation.
Important: The pool vacuum hose must be fully filled with water so that the pump does not lose prime and fill the
tank with air.
P. Winterize the system in cold weather climates
Unplug the pump from the power source.
Close the shut off valves or block the flow of water at the pool inlet and return ports.
Disconnect the filtration system from the pool, drain the tank and hoses.
Place the handle on the central valve in position 7- ‘Winterizeto relieve the tension on the spring and
internal valve components. This prevents the Diverter Gasket from becoming stuck to the gasket seat over
the winter and damaged in the spring start up procedure.
Store the filter system in a location protected from frost and severely cold temperatures. In a garage or
insulated storage shed is recommended.
Q. Important Do’s & Don’ts
DO’S:
Be aware and make note of the filter pressure when the sand is clean. Backwash when you see an increase
of 10 PSI on the pressure gauge.
Backwash long enough to clean the sand bed. Let the system backwash until the water leaving the waste
line is clear. Note that backwashing can remove 50 300 gal of water from your pool so pay attention.
Also, be aware of local codes regarding pool water disposal as some communities have rules or codes
regarding pool water drainage.
Protect bottom strainer while replacing or adding sand. Fill the tank with 8” 12” (about 1/8 of tank
height) of water. Cover the water chamber to avoid getting sand inside.
Start filter in Backwash mode for several minutes and then for about 1 minute in the rinse mode before
initial startup or after adding new sand. By doing this you can avoid blowing small particles and
impurities from the new sand into your pool. If some debris from new sand does go into your pool,
vacuum it with the system in purge mode, otherwise you may send it back to the pool.
8
DON’TS: Observe these cautions carefully or you may cause non-warranty damage to your filter
system.
Move valve handle while the pump is running. It will damage the valve and possibly other equipment as
well.
Backwash excessively. Sand filters operate more efficiently during mid-cycle. Some level of debris in the
sand bed actually helps filtration and makes the filter more effective. Too much backwashing will reduce
efficiency.
Vacuum the pool in backwash mode. You can plug up the strainer at the bottom of the filter which will
result in damage to the bottom strainer or at least inefficient operation. Plus you may have to remove all
of the sand to get it unclogged.
Let filtration system run dry (without water)! If your pump runs dry too long non-warranty damage to the
pump may occur. Damage to the pump caused by dry running is NOT covered by the warranty.
R. Trouble Shooting - See the expanded FlowXtreme Prime Pump Trouble Shooting section after the
Technical Data at the end of this manual. Additional information is provided in Section W.
Malfunction Cause Solution
Pressure gauge has reading
more than 10 PSI over the
normal filtering pressure
Dirty filter bed Backwash the filter (position 4)
Pressure is too low Hair and lint strainer basket is
dirty; Pump gets too little
water
Clean the hair and lint strainer; check the suction
line and the water level
Air in the pump Poor seal on the intake side of
pump
Tighten hose clamps and connecting fittings
Leaking filter Seal Defective Check the seal, replace if needed
Pump does not run Not plugged in Check the socket and power cord
G.F.C.I./ or main circuit
breaker tripped
Switch on the breaker. If it is immediately
tripped again, there may be a defect in pump,
pump controls, GFCI or the breaker
Pump motor defective Have the electrical system checked by a licensed
electrical professional or replace motor or entire
pump
Sand in Pool If the sand is newly replaced,
the undersized grains are still
present
Backwash several times until the backwash water
is clear (position 4)
Sand in Central Valve (from
backwash)
Purge into drainpipe for 30 seconds (position 6)
Filter bottom strainer is
damaged
Replace the filter bottom strainer
Air in system Loosen, but do not re-move, one of the clear
view port covers on the top of the filter tank to
allow any trapped air to escape. Tighten the
cover once all of the air has escaped.
S. Instal
l
l
ation an
d
d
Operat
i
i
on Illust
r
9
r
ation Fi
g
g
ures
10
T. FlowXtrem 16" AG SYSTEM NE4487/4488/4489 PARTS BREAKDOWN
AND DIAGRAMS
Key Part Name Qty Mnfg. No. B.W. No. For Model#
1 Valve Handle 1 V00152 NEP4289 NE4487/4488/4489
2 Valve Stem Pin 1 V00153 NEP4290 NE4487/4488/4489
3 Valve Cover 1 V00154 NEP4291 NE4487/4488/4489
4 Diverter Stem Spool 1 V00155 NEP4292 NE4487/4488/4489
5 Diverter Stem Gasket 1 V00156 NEP4293 NE4487/4488/4489
6 Diverter Stem Spring 1 V00157 NEP4294 NE4487/4488/4489
7 Diverter 1
V00126
NEP4287 NE4487/4488/4489
8 Diverter Gasket 1 NEP4287 NE4487/4488/4489
9 Valve Cover Seal 1 V00158 NEP4295 NE4487/4488/4489
10 Pressure Gauge 1 G00114 NEP4184 NE4487/4488/4489
11 Tank Cover 1 T00159 NEP4283 NE4487/4488/4489
12 Long INTEX Connector 1 I00160 NEP4233 NE4487/4488/4489
13 Flat Gasket For INTEX Connector 2 I00161 NEP4234 NE4487/4488/4489
14 Short INTEX Connector 1 I00162 NEP4235 NE4487/4488/4489
15 1 1/4" O-Ring For Long INTEX Connector 1 I00163 NEP4236 NE4487/4488/4489
16 View Port Cover 2 T00164 NEP4284 NE4487/4488/4489
17 Gasket For View Port Cover 2 T00165 NEP4285 NE4487/4488/4489
18 Seal Washer For Valve Cover Stems 9 V00166 NEP4296 NE4487/4488/4489
19 Valve Cover Screws 9 V00167 NEP4297 NE4487/4488/4489
20 Tank Seal 1 T00168 NEP4286 NE4487/4488/4489
21 Upper Distributor 1 T00116 NEP4273 NE4487/4488/4489
22
Lock Ring Pin
TANK COVER LOCK RING ASSEMBLY
1 L00169 NEP4237 NE4487/4488/4489
23
Left Side Lock Ring
TANK COVER LOCK RING ASSEMBLY
1 L00170 NEP4238 NE4487/4488/4489
24
Right Side Lock Ring
TANK COVER LOCK RING ASSEMBLY
1 L00171 NEP4239 NE4487/4488/4489
25
Lock Ring Bolt
TANK COVER LOCK RING ASSEMBLY
1 L00172 NEP4240 NE4487/4488/4489
26
Lock Ring Knob
TANK COVER LOCK RING ASSEMBLY
1 L00173 NEP4241 NE4487/4488/4489
27 Tank Separator Plate 1025 1 T00117 NEP4274 NE4487
27 Tank Separator Plate 1050 1 T00118 NEP4275 NE4488
27 Tank Separator Plate 1075 1 T00119 NEP4276 NE4489
11
28 Tank Bottom Strainer 1 T00120 NEP4277 NE4487/4488/4489
29 Filter Tank 1025 1 T00121 NEP4278 NE4487
29 Filter Tank 1050 1 T00122 NEP4279 NE4488
29 Filter Tank 1075 1 T00123 NEP4280 NE4489
30 Drain Cap 1 T00124 NEP4281 NE4487/4488/4489
31 Drain Cap Gasket 1 T00125 NEP4282 NE4487/4488/4489
32 Filter Pump Hose 1025 (W/Screw Head) 1 P00127 NEP4242 NE4487
32 Filter Pump Hose 1050 1 P00128 NEP4243 NE4488
32 Filter Pump Hose 1075 1 P00129 NEP4244 NE4489
33 Hose Clamp 1 P00174 NEP4260 NE4487
33 Hose Clamp 2 P00174 NEP4260 NE4488/4489
34
Pump Bolt Wing Nut
PUMP MOUNTING HARDWARE
2 P00175 NEP4261 NE4487/4488/4489
35
Pump Bolt Flat Water
PUMP MOUNTING HARDWARE
2 P00176 NEP4262 NE4487/4488/4489
36
Pump Bolt Lock Washer
PUMP MOUNTING HARDWARE
2 P00177 NEP4263 NE4487/4488/4489
37
Pump Bolt Nut
PUMP MOUNTING HARDWARE
2 P00178 NEP4264 NE4487/4488/4489
38 Base Plate 1 B00130 NEP4183 NE4487/4488/4489
39 Stainless Steel Gasket 2 V00185 NEP4298 NE4487/4488/4489
40 Spring Seat 1 V00186 NEP4299 NE4487/4488/4489
41
Hose Reducer 1 P00179 NEP4090 NE4487
Hose Reducer 2 P00179 NEP4090 NE4488/4489
12
13
U. TECHNICAL DATA for FlowXtreme Prime Single Speed Pump
Model #s; NE4523, NEP4268, NEP4269, NE4524, NEP4271
Technical Data
FlowXtreme PRIME, SPS1 Pumps Parts Breakdown & Diagram
Key Part Name Qty Mnfg. No. B.W. No. For Model#
1 Water Pump/ Motor 250 W 1 SPS1A250 NEP4268 NEP4268
1 Water Pump/ Motor 450 W 1 SPS1A450 NEP4269 NEP4269
1 Water Pump/ Motor 550 W 1 SPS1A550 NE4523 NE4523
2
Transparent Hair & Lint Strainer
Cover
1 P00131 NEP4245 NEP4268/NEP4269/NE4523
3 1 1/4"- 1 1/2" Hose Connector 2 P00132 NEP4246 NEP4268/NEP4269/NE4523
4 O-ring "A"- 2 1/4" 1 P00182 NEP4265 NEP4268/NEP4269/NE4523
5 O-ring "B"- 3" 1 P00183 NEP4266 NEP4268/NEP4269/NE4523
6 O-ring "C"- 1.5" 1 P00184 NEP4267 NEP4268/NEP4269/NE4523
7 Strainer Collar 1 P00133 NEP4247 NEP4268/NEP4269/NE4523
8 Strainer Basket 1 P00134 NEP4248 NEP4268/NEP4269/NE4523
9 Pump Drain Cap 1 P00135 NEP4249 NEP4268/NEP4269/NE4523
10 Drain Valve O-ring 1 P00136 NEP4250 NEP4268/NEP4269/NE4523
11 Motor Pump Seal - 250 1 P00137 NEP4251 NEP4268/NEP4269/NE4523
11 Motor Pump Seal - 450 1 P00138 NEP4252 NEP4268/NEP4269/NE4523
11 Motor Pump Seal - 550 1 P00138 NEP4252 NEP4268/NEP4269/NE4523
12 Impeller Assembly - 250 1 P001392 NEP4253 NEP4268
12 Impeller Assembly - 450 1 P001404 NEP4254 NEP4269
12 Impeller Assembly - 550 1 P001405 NEP20200 NE4523
13 Shaft Seal & Spring Assbly – 250 1 P00141 NEP4255 NEP4268/NEP4269/NE4523
13 Shaft Seal & Spring Assbly - 450 1 P00142 NEP4256 NEP4268/NEP4269/NE4523
13 Shaft Seal & Spring Assbly - 550 1 P00142 NEP4256 NEP4268/NEP4269/NE4523
14 Power Cord With 3 Prong Plug 1 P00143 NEP20201 NEP4268/NEP4269/NE4523
Model HP Voltage Hertz Amps Flow Rate GPM
NE4523 0.75 115 60 5.5 38GPM
NEP4268 0.33 115 60 2.5 24GPM
NEP4269 0.50 115 60 4.5 35GPM
NE4524 1.50 115 60 15.5 115GPM
NEP4271 1.0 115 60 11.0 90GPM
F
Key
1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
15
16
lowXtre
m
P
Water Pu
m
Water Pu
m
Valve Bod
y
Connector
Pump Con
n
Pump Con
n
Strainer B
a
O-Sealing
R
Transpare
n
Circumgyr
Drain Val
v
Pump Dra
i
Basket Co
v
Power Cor
Motor Pu
m
Impeller
A
Impeller
A
Shaft Seal
m
e PRIM
E
P
art Name
m
p
m
p
y
O-Ring
n
ecto
r
n
ector Nu
t
a
ske
t
R
ing
n
t Cove
r
ate Cove
r
v
e O-Ring
i
n Valve
v
er Closing T
o
d with 3 pron
g
m
p Seal
A
ssembly - 11
0
A
ssembly - 16
0
& Spring As
s
E
, SPS3
P
M
odel #s
;
Qt
y
1
1
1
1
1
1
1
1
1
1
2
2
o
ol 1
g
plug 1
1
0
0 1
0
0 1
s
embly 1
14
P
umps P
a
;
NEP42
7
y
Mnf
g
.
SPS3
1
SPS3
1
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
a
rts Brea
k
7
1, NE45
2
No. B.
W
1
100
N
E
P
1
600
N
E
P
S3
N
E
P
S3
N
E
P
S3
N
E
P
S3
N
E
P
S3
N
E
P
S3
N
E
P
S3
N
E
P
S3
N
E
P
S3
N
E
P
S3
N
E
P
S3
N
E
P
S3
N
E
P
S3
N
E
P
S3
N
E
P
S3
N
E
P
S3
N
E
P
k
down &
2
4
W
. No.
P
4271
P
4254
P
4128
N
P
4129
N
P
4130
N
P
4131
N
P
4132
N
P
4133
N
P
4134
N
P
4135
N
P
4136
N
P
4137
N
P
20202
N
P
20203
N
P
20204
N
P
20205
P
20206
P
20207
N
Dia
g
ra
m
For Mode
l
N
EP427
1
NE4524
N
EP4271 & N
E
N
EP4271 & N
E
N
EP4271 & N
E
N
EP4271 & N
E
N
EP4271 & N
E
N
EP4271 & N
E
N
EP4271 & N
E
N
EP4271 & N
E
N
EP4271 & N
E
N
EP4271 &
NE
N
EP4271 & N
E
N
EP4271 & N
E
N
EP4271 & N
E
NEP4271
NE4524
N
EP4271 & N
E
m
l
#
1
E
4524
E
4524
E
4524
E
4524
E
4524
E
4524
E
4524
E
4524
E
4524
E
4524
E
4524
E
4524
E
4524
E
4524
V. Trou
b
Motor W
i
Make sure t
h
for available
1. Impr
o
Solutio
2. Man
u
3. If yo
u
Motor Sh
u
1. Low
Solutio
2. Mot
o
Solutio
NOTE
b
leshooti
n
i
ll NOT St
a
h
e terminal b
o
field supply
v
oper or loose
n: Check all
c
u
ally check r
o
u
have a time
r
u
ts OFF –
C
voltage at m
o
n: Contact q
u
o
r may be ove
n: Check wa
t
- Your pump
ng
for an
d
a
rt – Chec
k
o
ard connecti
o
v
oltage (see p
wiring conne
c
c
onnections,
c
o
tation of mot
o
r
, be certain i
t
C
heck For
o
tor or power
u
alified profe
s
rheating due
t
t
er flow to ins
u
motor is equ
i
d
FlowXt
r
k
For:
o
ns agree wit
h
u
mp operatin
g
c
tions; open
s
c
ircuit breake
r
o
r shaft for fr
e
t
is working p
r
:
drop (freque
n
s
sional to che
c
t
o direct sunli
g
u
re uniform a
i
pped with an
15
r
eme Pri
m
h
the wiring d
i
g
label).
s
witches or re
l
r
s, and fuses.
R
e
e movement
roperly. Byp
a
n
tly caused by
c
k that the wi
r
ght or low w
a
a
mount of wa
t
“automatic t
h
m
e Pum
p
i
agram on mo
t
l
ays; tripped
c
R
eset tripped
and lack of o
b
a
ss it if necess
undersized
w
r
ing gauge is
h
a
ter level in t
h
er coming to
t
h
ermal overlo
a
p
s
t
or data plate
c
ircuit breake
r
breakers or r
e
b
struction.
ary.
w
iring or exte
n
h
eavy enough
h
e pump bask
e
t
he pump.
a
d protector.”
label. Be sur
e
r
s, GFCI’s, o
r
e
place blown
n
sion cord us
e
h
.
e
t.
The motor
w
e
motor is wir
e
blown fuses.
fuses.
e
).
w
ill
e
d
16
automatically shut off if power supply drops before heat damage can build up causing windings to burn out. The
“thermal overload protector” will allow the motor to automatically restart once the motor has cooled. It will continue
to shut off until the problem is corrected. Be sure to correct cause of overheating.
Motor Hums, But Does NOT Start – Check For:
1. Impeller jammed with debris.
Solution: Have a qualified repair professional open the pump and remove the debris.
2. Motor is frozen either form months in the carton after manufacturing or from over winter storage.
Solution: Insert a flat bladed screw driver into the slot at the back end of the motor shaft and turn motor shaft until it
moves freely. You may have to remove the protective metal cap from some models to access the motor shaft.
NOTE – All FlowXtreme & FX PRO II pumps are run tested with water before leaving the factory.
Pump Won't Prime - Check For:
1. Empty pump/strainer housing
Solution: Make sure pump/strainer housing is filled with water and cover o-ring is clean. Ensure o-ring is properly
seated in the cover o-ring groove. Ensure o-ring is lubricated and that strainer cover is locked firmly in position.
Lubricant will help to create a tighter seal.
2. Loose connections on suction side.
Solution: Tighten pipe/union connections or hose clamps on flexible hose.
NOTE - Any self-priming pump will not prime if there are suction air leaks. Leaks will result in bubbles emanating
from return fittings on In Ground pool wall.
3. Leaking O-ring on valves.
Solution: Tighten, repair, or replace valves.
4. Strainer basket or skimmer basket loaded with debris.
Solution: Remove strainer housing cover or skimmer cover, clean basket, and refill strainer housing with water.
Tighten cover.
Low Flow – Generally, Check For:
1. Clogged or restricted strainer or suction line.
Solution: Check for visible debris and remove if observed. If the problem continues contact a qualified repair
professional.
2. Undersized pool plumbing.
Solution: Correct plumbing size.
3. Plugged or restricted discharge line of filter, valve partially closed (high gauge reading).
Solution: Sand filters – backwash as per manufacturer’s instructions; D.E. filters – backwash as per manufacturer’s
instructions; Cartridge filters – clean or replace cartridge.
4. Air leak in suction (bubbles issuing from return fittings).
Solution: Re-tighten suction and discharge connections using Teflon tape. Inspect other plumbing connections and
tighten as required.
5. Plugged, restricted, or damaged impeller.
Solution: Contact a qualified repair professional to install a new impeller & seal assembly.
17
Noisy Pump – Check For:
1. Air leak in suction piping, cavitation caused by restricted or undersized suction line or leak at any joint, low water
level in pool, and unrestricted discharge return lines.
Solution: Correct suction condition or tighten fittings, if practical. Holding hand over return fitting will sometimes
prove this point or putting in a smaller return eyeball fitting.
2. Vibration due to improper mounting, etc.
Solution: Mount the pump on a level surface and secure the pump to the equipment pad.
3. Foreign matter in pump housing. Loose stones/debris hitting impeller will cause noise.
Solution: With the pump turned off or disconnected from the power source clean the pump housing and inspect to
remove any debris visible in the inner portion of the pump by the impeller.
4. Motor bearings noisy from normal wear, rust, overheating, or concentration of chemicals causing seal damage.
This will allow chlorinated water to seep into bearings wiping out the grease resulting in rusting of the motor shaft
and causing the bearing to whine.
Solution: All seal leaks must be replaced at once. Have a qualified pump repair specialist replace the motor shaft
seals and inspect the motor shaft for possible damage. If the motor shaft is damaged replace the motor.
Water Leaks Around Intake and Discharge fittings – Check For
1. Lose union fittings or hose fittings.
Solution: Tighten fittings or remove, apply Teflon tape and reinstall.
2. Lose hose clamps on flexible hose.
Solution: Tighten hose clamps using a nut driver or wrench instead of a screwdriver
3. Leaks that continue after trying the above solutions.
Solution: Inspect union fittings and hose fittings for excess plastic mold flashing that can cause hoses and plumbing
not to seal. If plastic mold flashing is found remove it with a fine tooth file or knife blade and re-assemble. If the
fitting still will not seal replace them and reassemble plumbing with the new fittings.
ATTENTION
DO NOT RETURN THIS PRODUCT TO YOUR RETAILER. IF
YOU ENCOUNTER ANY DIFFICULTIES WITH YOUR NEW
SWIMMING POOL PUMP CONTACT BLUE WAVE CUSTOMER
SERVICE FOR ASSISTANCE.
1-800-759-0977
18
W. Warranty Information
This product is warranted to the original purchaser to be free from defects in material or workmanship for a
period of one (1) year from the date of the original retail purchase.
This warranty does not cover defects or damage due to improper installation, alteration, accident or any other
event beyond the control of the manufacturer. Defects or damage resulting from misuse, abuse or negligence
will void this warranty. This warranty does not cover scratching or damage that may result from normal usage.
This product is not intended for institutional or commercial use; the manufacturer does not assume any
liability for such use. Institutional or commercial use will void this warranty.
This warranty is nontransferable and is expressly limited to the repair or replacement of the defective product.
During the warranty period, the manufacturer shall repair or replace defective parts at no cost to the purchaser.
Shipping charges and insurance are not covered and are the responsibility of the purchaser. Labor charges and
related expenses for removal, installation or replacement of the product or components are not covered under
this warranty.
The manufacturer reserves the right to make substitutions to warranty claims if parts are unavailable or
obsolete.
The manufacturer shall not be liable for loss of use of the product or other consequential or incidental costs,
expenses or damages incurred by the consumer of any other use. The user assumes all risk of injury resulting
from the use of this product.
This warranty is expressly in lieu of all other warranties, expressed or implied, including warranties of
merchantability or fitness for use to the extent permitted by Federal or state law. Neither the manufacturer nor
any of its representatives assumes any other liability in connection with this product.
All warranty claims must include the retailer’s information where the product was originally purchased.
A purchase receipt or other proof of date of purchase will be required to process all warranty claims.
The model number and part numbers found within the assembly instructions will be required when
submitting any parts requests or warranty claims.
For further warranty information or inquiries, please call 1 (800) 759-0977 Or email
warranty@splashnetxpress.com
Blue Wave Products, Inc.
1745 Wallace Ave, Suite B
Saint Charles, IL 60174
19
La garantie du produit est valide pour l'acheteur original en ce qui a trait aux pièces défectueuses ou à la
main-d’œuvre pour une période de 1 année de la date d’achat.
Cette garantie n’est couvre pas les dommages causés par accident, par modification, par une installation
défectueuse ou tout autre événement hors du contrôle du fabricant. Tout défaut ou dommage résultant de la
négligence ou d’une mauvaise utilisation annule cette garantie. La présente garantie ne couvre pas les
égratignures ou les dommages attribuables à un usage normal.
Ce produit n'est pas destiné à un usage institutionnel ou commercial; le fabricant décline toute responsabilité
pour une telle utilisation. Un usage institutionnel ou commercial annule cette garantie.
Cette garantie est non transférable et est expressément limitée à la réparation ou au remplacement du produit
défectueux. Au cours de la période de garantie, le fabricant s’engage à remplacer et à réparer les pièces
défectueuses sans frais pour l’acheteur. Les frais d’assurance et d'expédition ne sont pas couverts et sont à la
charge de l'acheteur. Les frais de main-d'œuvre et les dépenses liées au déplacement, à l’installation ou au
remplacement du produit ou de ses composantes ne sont pas couverts par cette garantie.
Le fabricant se réserve le droit de faire des substitutions de recours en garantie si la pièce n'est pas disponible
ou obsolète.
Le fabricant décline toute responsabilité liée à la perte d'utilisation ainsi que tous les autres coûts directs ou
indirects, frais ou dommages encourus par le consommateur qui aurait été causés par une autre utilisation.
L'utilisateur assume tous les risques de dommage résultant de l'utilisation de ce produit.
Cette garantie tient lieu expressément de toute autre garantie, exprimée ou implicite, y compris les garanties de
qualité marchande ou d'adaptation à un emploi particulier dans la mesure permise par les lois fédérales ou
provinciales. Ni le fabricant, ni aucun de ses représentants n'assument aucune autre responsabilité en rapport
avec ce produit.
Toute réclamation doit être faite par le détaillant où le produit a été acheté. Une facture ou autre preuve
d'achat est nécessaire pour traiter toutes les réclamations de garantie. Le numéro de modèle et les
numéros de référence figurant dans les instructions d'assemblage seront exigés lors de la soumission de
demande de pièces ou de recours en garantie.
Pour plus d’information ou pour toute question, veuillez téléphoner au 1 (800) 759-0977 ou email
warranty@splashnetxpress.com
Blue Wave Products, Inc.
1745 Wallace Ave, Suite B
Saint Charles, IL 60174
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

FlowXtreme FlowXtreme NE4489 Manuel utilisateur

Catégorie
Accessoires de piscine hors terre
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues