Vemer Set sicurezza gas GPL 3/4" Manuel utilisateur

Catégorie
Éclairage de confort
Taper
Manuel utilisateur
Rivelatori di Gas
RGG-RGM WAVE
Manuale d’Uso
Gas Detectors User Manual
- 3 -
Manuale Rivelatori di Gas
DIMENSIONI / DIMENSIONS - (A)
DIMENSIONI - (A)
RGM
Wave
Rivelatore di Gas Metano
Natural Gas Detector
Guasto
Fault
Allarme
Alarm
152
91
ON
91
44
POSIZIONAMENTO / POSITIONING - (B)
- 4 -
Manuale Rivelatori di Gas
- 4 -
Manuale Rivelatori di Gas
POSIZIONAMENTO - (B)
Max 30 cm
1 ÷ 4 m
Max 30 cm
1 ÷ 4 m
Wave
Guasto
Fault
Allarme
Alarm
ON
RGM
Wave
Rivelatore di Gas Metano
Natural Gas Detector
Guasto
Fault
Allarme
Alarm
ON
RGM
Wave
Rivelatore di Gas Metano
Natural Gas Detector
Guasto
Fault
Allarme
Alarm
ON
RGM
Wave
Rivelatore di Gas Metano
Natural Gas Detector
Guasto
Fault
Allarme
Alarm
ON
Wave
Guasto
Fault
Allarme
Alarm
ON
RGG - (B1)
RGM - (B2)
- 5 -
Manuale Rivelatori di Gas
MONTAGGIO / ASSEMBLY - (C)
- 6 -
Manuale Rivelatori di Gas
MONTAGGIO - (C)
3
1
4
2
- 6 -
Manuale Rivelatori di Gas
MONTAGGIO / ASSEMBLY - (C1 a)
- 6 -
Manuale Rivelatori di Gas
MONTAGGIO - (C1 a)
- 7 -
Manuale Rivelatori di Gas
MONTAGGIO / ASSEMBLY - (C1 b)
- 7 -
Manuale Rivelatori di Gas
MONTAGGIO - (C1 b)
- 8 -
Manuale Rivelatori di Gas
MONTAGGIO / ASSEMBLY - (C2)
- 8 -
Manuale Rivelatori di Gas
MONTAGGIO - (C2)
(C3)
1
2
1
J1
BB
AA
- 9 -
Manuale Rivelatori di Gas
COLLEGAMENTI ELETTRICI / ELECTRICAL CONNECTIONS - (D)
5
5
- 9 -
Manuale Rivelatori di Gas
COLLEGAMENTI ELETTRICI - (D)
J1
BB
AA
L N
NC C NA
L N
NC C NA
L N
RGG/RGM - (D2)
~
2
3
0
V
~
5
0
H
z
NC
BB
~
2
3
0
V
~
5
0
H
z
L N
NA
RGG/RGM - (D1)
AA
5
J1
BB
AA
5
- 10 -
Manuale Rivelatori di Gas
Sostituire entro
Replace within
Da compilarsi a cura dell'installatore
Fill in the form carefully
Data di
installazione
Lotto
di
fabbricazione
Locale di
installazione
Timbro
e Firma
installatore
Installation
date
Manufacturing
lot
Installation
room
Installator
signature and
stamp
- 10 -
Manuale Rivelatori di Gas
ETICHETTA DI SOSTITUZIONE / REPLACEMENT LABEL - (E)
SCHEDA DI INSTALLAZIONE / INSTALLATION CARD - (F)
Italiano
- 11 -
Manuale Rivelatori di Gas
ISTRUZIONI PER L’INSTALLAZIONE
POSIZIONAMENTO (g. B)
Installare in luoghi con un buon ricircolo d’aria (NON dietro a porte, tendaggi,
arredi, ...), lontano da aperture o condotti di ventilazione, al sicuro da possibili
urti o getti d’acqua.
Evitare zone particolarmente umide o con accumuli di polvere e con
temperature al di fuori di quelle consentite.
NON installare al di sopra o presso apparecchiature a gas (piccoli rilasci
all’accensione potrebbero provocare interventi intempestivi).
NON installare sopra fornelli (il vapore generato dalla cottura potrebbe
danneggiare il rivelatore)
NON installare sopra o vicino ai lavelli perché il vapore o gli spruzzi possono
causare malfunzionamenti
NON installare vicino a detergenti, solventi, vernici, lucidanti e simili perc
potrebbero sprigionare gas o sostanze che possono influenzare l’affidabilità
del dispositivo nel breve o nel lungo periodo (ad esempio: acetone,
ammoniaca, alcool, vapori siliconici);
Modello RGG (g. B1): posizionare il rivelatore su una parete liscia ad
un’altezza max. di 30 cm dal pavimento e ad una distanza compresa
tra 1 e 4 m dall’apparecchiatura da controllare.
Modello RGM (fig. B2): posizionare il rivelatore su una parete liscia ad
un’altezza max. di 30 cm dal softto e ad una distanza compresa tra 1 e 4 m
dall’apparecchiatura da controllare.
MONTAGGIO (g. C)
Aprire il dispositivo (fig. C1 a) e rimuovere la basetta che alloggia il circuito
elettronico (g. C2).
Predisporre i cavi di comando dell’elettrovalvola e i cavi di alimentazione del
rivelatore utilizzando le fessure presenti nella base del dispositivo (fig. C: )
Per il collegamento del rivelatore e della eventuale elettrovalvola utilizzare
cavi sottotraccia.
Fissare la base del rivelatore sulla parete (fig C3) usando le viti in
dotazione.
Riposizionare la basetta che alloggia il circuito elettronico sulla base del
rivelatore (fig. C2).
Effettuare i collegamenti elettrici (vedi voce COLLEGAMENTI ELETTRICI)
Italiano
Compilare l’etichetta (fig. E) con la data di sostituzione (data di installazione
più 4 anni) ed applicarla in posizione visibile sulla copertura del rivelatore.
Riposizionare la copertura (g. C1 b) ed alimentare il rivelatore.
Compilare la scheda d’installazione (g. F) e consegnarla, unitamente al
manuale d’uso, all’utente.
COLLEGAMENTI ELETTRICI (fig. D)
Prima di accedere ai morsetti assicurarsi che i conduttori elettrici non siano in
tensione
Posizionare il ponticello “J1” in funzione del tipo di elettrovalvola da
comandare:
Elettrovalvola normalmente aperta (NA) a riarmo manuale (ponticello sui
piedini BB, fig. D1).
Elettrovalvola normalmente chiusa (NC) a riarmo manuale (ponticello sui
piedini AA, fig. D2).
Collegare i cavi dell’alimentazione (230 V AC) ai morsetti L-N e i cavi di
comando dell’elettrovalvola ai morsetti C-NA
NOTA: l’apparecchio diventa operativo 30 secondi dopo averlo alimentato.
FUNZIONAMENTO
A causa dell’inevitabile decadimento delle caratteristiche chimico-fisiche
dell’elemento sensibile, il rivelatore funziona correttamente per un periodo di 4
anni a partire dalla data di alimentazione
Indicazioni luminose
LED VERDE (ON): dispositivo alimentato
LED GIALLO (): funzionamento del sensore non corretto; in questo caso il
rivelatore va considerato guasto
LED ROSSO (): rivelatore in stato di allarme; contemporaneamente viene
attivata anche una segnalazione acustica mentre il relè commuta dopo 30 s (se
rimane la condizione di allarme).
Stato di allarme: quando la concentrazione di gas nel locale in cui il rivelatore
è installato supera la soglia di sicurezza, viene attivata una segnalazione
acustica e luminosa (luce rossa ); il relè commuta se lo stato d’allarme
permane per più di 30 s. Le segnalazioni acustiche e luminose restano attive
finché la concentrazione di gas non rientra nei limiti di sicurezza (oppure finché
non viene tolta l’alimentazione).
EVITARE di bagnare o urtare il rivelatore (ad esempio durante le normali
operazioni di pulizia domestica)
- 12 -
Manuale Rivelatori di Gas
Italiano
- 13 -
Manuale Rivelatori di Gas
Il dispositivo è tarato per intervenire prima che la concentrazione di gas
raggiunga il L.I.E. (limite inferiore di esplosività: 5% per il metano, 1,8% per il
butano, principale componente del gpl), cioè prima che possa instaurarsi un
pericolo d’esplosione.
In caso di allarme: spegnere le fiamme libere, chiudere il rubinetto del gas
o della bombola, non accendere luci, non azionare dispositivi elettrici, aprire
porte e finestre, individuare ed eliminare la causa dell’allarme. Se la causa
dell’allarme non è individuabile, abbandonare il locale ed avvisare il servizio
d’emergenza
Soglie di allarme
RGM: 8% del L.I.E. del metano
RGG: 8% del L.I.E. del GPL
PULIZIA
Attenzione: Pulire la calotta del dispositivo con un panno morbido asciutto e
non abrasivo. Non fare uso di solventi, lucidanti e detergenti perché potrebbero
influenzare l’affidabilità del dispositivo.
ATTENZIONE:
È possibile avvertire odore di gas prima che scatti l’allarme; ciò accade
perché nel posto dove è installato il rivelatore non si è ancora raggiunta la
concentrazione critica di gas.
NORME DI RIFERIMENTO
La conformità alle Direttive Comunitarie
2006/95/CE (Bassa tensione)
2004/108/CE (Compatibilità elettromagnetica)
è dichiarata in riferimento alla seguente norma armonizzata: EN 50194.
- 14 -
English
- 15 -
Gas detectors User Manual
Index
Safety warnings Page 16
Technical specifications Page 16
Dimensions Page 3
Installation instructions Page 17
Positioning Page 17
Assembly Page 18
Electrical connections Page 18
Operation Page 18
Reference standards Page 20
English
SAFETY WARNINGS
1) The device should be installed by qualified personnel
2) Power supply must be equipped by bipolar circuit breaker; Connection
terminals have cross section of 1,5mm2
3) Before removing the cover, isolate the power supply and make sure there is
NO power to the device
4) Before touching the terminals, make sure there is no power supply to the
electric wires
5) Install the detector in the correct position (see Positioning)
6) Do not power the instrument if any part of it is damaged
7) Danger of electrical shock or malfunctioning in case of manumission or
misuse of the device
8) Do not operate the device for longer than the time indicated in the label
The installation of the gas detector does not affect the need to comply
with all the regulations regarding the specifications, installation and use
of gas appliances, the ventilation of the rooms and the discharge of the
combustion product, as laid down in the UNI EN 1775 standards for the
application of article 3 of law no. 1083/71 and the legislation in force.
TECHNICAL SPECIFICATIONS
Power supply: 230 V AC 50 Hz (-15%/+10%)
Power absorbed: 4 VA
Operating conditions: temperature -10 ÷ +40 °C
humidity 30 ÷ 90%
Protection level: IP42
Noise pressure of the acoustic warning device: 85 dBA at 1 m
Contact capacity: 8(2) A 250 V AC
Code Model Description
VN783700 RGM WAVE Bianco Siberian Methane gas detector
VN784500 RGM WAVE Aluminium Raider Methane gas detector
VN785200 RGG WAVE Bianco Siberian LPG gas detector
VN786000 RGG WAVE Aluminium Raider LPG gas detector
- 16 -
Gas detectors User Manual
English
LEGEND
A) Dimensions (page 3)
B) Positioning
C) Assembly
Detector base
Base housing the electronic circuits
Cover
Cable outlet for fixing to the built-in box (type 503 or equivalent)
D) Electrical connections
jumpers
E) Replacement label (page 10)
F) Installation card (page 10)
INSTALLATION INSTRUCTIONS
POSITIONING (g. B page 4)
Install in rooms where there is good air circulation (NOT behind doors,
curtains, furniture, etc), away from ventilation openings or ducts, protected
from shock or sources of water.
Avoid particularly damp zones or those with dust build-ups or temperatures
outside the range specified.
Do NOT install over or near gas appliances (minor leakage on switching on
could cause incorrect activation).
Do NOT install over cookers (the steam generated during cooking could
damagethe detector)
NOT to be installed close to water sources, steam and water dip may cause
malfunctions
NOT to be installed close to recipient of paints, thinners, cleaners etc.; such
substances may release gas that can affect to good functioningof detector
(detector is particularly sensitive to ammonia, thinners,solvents, etc)
Model RGG (g. B1): position the detector on a smooth wall at a maximum
height of 30 cm from the floor and at a distance from 1 to 4 metres from the
appliances to be controlled.
Model RGM (g. B2): position the detector on a smooth wall at a maximum
height of 30 cm from the ceiling) at a distance between 1 and 4 metres
from the appliances to be controlled.
- 17 -
Gas detectors User Manual
English
ASSEMBLY (fig. C page 5)
Open the device (g. C1 a) and remove the base that houses the electronic
circuit (fig. C2).
Fit the solenoid valve control cables and the detector power cables in the
approprite slots in the base of the device (fig. C: ). For electrical connection
of both, detector and valve, use only in-wall wires.
Fix the base of the detector to the wall (fig C3) using the screws supplied.
Replace the base that houses the electronic circuit on the base of the
detector (fig. C2).
Make the electrical connections (see ELECTRICAL CONNECTIONS”)
Fill in the label (fig. E) with the replacement date (date of installation plus 4
years) and apply it in a clearly visible position of the detector cover.
Replace the cover (fig. C1 b) and power the detector.
Fill in the installation schedule (g. F) and hand it over to the user, together
with the user manual.
ELECTRICAL CONNECTIONS (fig. D page 9)
Before touching the terminals, make sure there is no power supply to the
electric wires
Position jumper “J1” in accordance with the type of solenoid valve to be
controlled:
Normally open manual rearm solenoid valve (NO) (jumper on legs BB, fig. D1).
Normally closed manual rearm solenoid valve (NC) (jumper on legs AA,
fig. D2).
Connect the power supply cables (230 V AC) to the L-N terminals and the
solenoid valve control cables to the C-NA terminals
NOTE: the appliance will come into operation 30 seconds after being
switched on.
OPERATION
Due to the inevitable deterioration of the chemical and physical characteristics
ofthe sensitive element, the detector will operate correctly for a period of 4
years from the date of activation
Warning lamps
GREEN WARNING LAMP (ON): power on
YELLOW WARNING LAMP (): incorrect sensor operation. The detector is
faulty
- 18 -
Gas detectors User Manual
English
RED WARNING LAMP ():detector in alarm status. An acoustic warning
signal is issued at the same time and the relay switches after 30 seconds (if the
alarm condition remains).
Alarm status: when the concentration of gas in the room where the detector
is installed exceeds the safety threshold, an acoustic and light warning signal
is activated (red warning lamp ); the relay switches if the alarm status
continues for more than 30 seconds. The acoustic and light warning signals
remain active until the gas concentration returns within the safety limits (or the
power supply is cut off).
AVOID getting the detector wet or subjecting it to shock (during normal
household cleaning operations, for example)
the device may control a normally open (NO) or normally closed (NC) solenoid
valve to cut off the combustible gas
The device is calibrated to intervene before the concentration of gas reaches
the L.L.E. (lower limit of explosiveness: 5% for methane, 1.8% for butane, the
main component of LPG), that is, before the concentration creates a risk of
explosion.
In the event of alarm:: switch off naked flames, close the gas tap or the
cylinder, do not switch on lights or, activate electrical equipment.
Open doors and windows, identify the cause of the alarm and eliminate it.
If it is not possible to identify the cause of the alarm, leave the room and call
the emergency services
Alarm thresholds
RGM: 8% of the L.L.E. for methane
RGG: 8% of the L.L.E for LPG
CLEANING
Attention: Clean up the cap of the device with a dry, soft, not abrasive cloth.
Don’t use dissolvent, polishing and detergents because they could influence the
reliability of the device.
CAUTION:
May happen to smell gas before alarm takes ON, this is normal; it may happen
according to where detector is located; in fact gas detector react according to
gas concentration on the room.
- 19 -
Gas detectors User Manual
English
- 20 -
Gas detectors User Manual
REFERENCE STANDARDS
Conformity to the European Community directives
2006/95/EC (Low voltage)
2004/108/EC (Electromagnetic compatibility)
is declared with reference to the following harmonised standards: EN 50194
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23

Vemer Set sicurezza gas GPL 3/4" Manuel utilisateur

Catégorie
Éclairage de confort
Taper
Manuel utilisateur