Eaton Crouse-hinds series Operating Instructions Manual

Taper
Operating Instructions Manual

Ce manuel convient également à

Steckvorrichtungen für Industrieanwendungen
63 A, 3-polig, 4-polig und 5-polig, GHG 524
Plug and socket system for industrial use
63 A, 3-pole, 4-pole and 5-pole, GHG 524
Fiches et prises de 63 A, à 3 pôles, 4 pôles et 5 pôles,
pour utilisation industrielle, GHG 524
GHG 510 7003 P0003 D/GB/F (i)
CROUSE-HI NDS
SERIES
Betriebsanleitung
Operating instructions
Mode d’emploi
2
Steckvorrichtungen für Industrie-
anwendungen 63 A, 3-polig,
4-polig und 5-polig, GHG 524
Plug and socket system for
industrial use 63 A, 3-pole,
4-pole and 5-pole, GHG 524
Fiches et prises de 63 A,
à 3 pôles, 4 pôles et 5 pôles,
pour utilisation industrielle, GHG 524
Inhalt:
Inhalt ....................................................... 2
Maßbild ................................................ 3-4
Anschlussbild .......................................... 6
1 Technische Angaben ............................... 3
1.1 Steckvorrichtung GHG 524 ..................... 3
2 Sicherheitshinweise ................................ 4
3 Normenkonformität ................................. 4
4 Verwendungsbereich .............................. 4
5 Verwendung / Eigenschaften .................. 4
6 Installation ............................................... 5
6.1 Montage .................................................. 5
6.2 Öffnen des Gerätes /
Elektrischer Anschluss
............................ 5
6.3 Kabel- und Leitungseinführung;
Verschlussstopfen
................................... 5
6.4 Schließen des Gerätes ............................ 6
6.5 Inbetriebnahme ....................................... 6
7 Instandhaltung/Wartung .......................... 6
8 Reparatur / Instandsetzung /
Änderungen
............................................ 6
9 Entsorgung / Wiederverwertung ............. 6
Konformitätserklärung separat beigelegt.
Contents:
Contents ................................................. 2
Dimensional drawings ...........................7-8
Connection diagram ...............................10
1 Technical data .......................................... 7
1.1 Plug and socket GHG 524 ....................... 7
2 Safety instructions .................................. 8
3 Conformity with standards ...................... 8
4 Field of application .................................. 8
5 Application/Properties ............................. 8
6 Installation ............................................... 9
6.1 Mounting ................................................. 9
6.2 Opening the device /
Electrical connection
............................... 9
6.3 Cable entry (KLE);
blanking plug
........................................... 9
6.4 Closing the device ..................................10
6.5 Taking into operation ..............................10
7 Maintenance/Servicing...........................10
8 Repairs/Modifications ............................10
9 Disposal/Recycling .................................10
Declaration of conformity, enclosed separately.
Contenu:
Contenu .................................................. 2
Plans cotés ........................................ 11-12
Diagram de connexion ...........................14
1 Caractéristiques techniques ..................11
1.1 Fiche et prise GHG 524 ..........................11
2 Consignes de sécurité ...........................12
3 Conformité avec les normes ..................12
4 Domaine d’utilisation .............................12
5 Utilisation/Propriétés ..............................12
6 Installation ..............................................13
6.1 Montage .................................................13
6.2 Ouverture de l’appareil /
Raccordement électrique
.......................13
6.3 Entrées de câble (KLE)
bouchons de fermeture
.........................13
6.4 Fermeture de l’appareil ..........................14
6.5 Mise en service ......................................14
7 Maintien/Entretien .................................14
8 Réparation / Remise en état /
Modifications
.........................................14
9 Évacuation des déchets / Recyclage ......14
Déclaration de conformité, jointe séparément.
3
Wandsteckdose ohne Schalter
Maßbilder in mm
X = Befestigungsmaße
1 Technische Angaben
1.1 Steckvorrichtungen GHG 524
Bemessungsspannung UN bis 690 V, 50/60 Hz
Max. Bemessungsstrom 63 A
Max. Vorsicherung
ohne therm. Schutz 63 A gG
Schaltvermögen AC 22
Wandsteckdose mit Schalter 415 V / 63 A
500 V / 63 A
690 V / 63 A
Zulässige Umgebungstemperatur -20° C bis +40° C (Listenausführung)
(Abweichende Temperaturen sind bei Sonderversionen möglich)
Zul. Lagertemperatur in Originalverpackung: -20° C bis +40° C
Schutzart bei geschlossenem und gesichertem
Klappdeckel sowie ordnungsgemäß gesteckten
Exponaten nach EN/IEC 60529
IP 66 (Listenausführ
ung)
Schutzklasse nach EN/IEC 61140 I - wird von den Geräten erfüllt
Leitungseinführung: (Listenausführung)
Wandsteckdose mit Schalter 1 x M50 + 1 x Verschluss M50
geeignete Leitungen und Prüfdrehmomente der
Druckschraube
Ø Nm
Dicht
ung 1+2
1 2
3
min.
max.
(1)
24,0
28,0
6
,0
7,0
Dichtung 1
1 2
3
min.
max.
(1)
28,0
35,0
5
,0
7,0
Prüfdrehmomente Einschraubgewinde 7,5 Nm
(1)
Die Prüfungen der Klemmbereiche und Prüfdrehmomente wurden mit Metalldornen durchgeführt.
Bei der Verwendung von Leitungen mit unterschiedlichen Fertigungstoleranzen und Materialeigenschaften kann
der Klemmbereich v
ariieren. Bitte verwenden Sie im Zwischenbereich eine geeignete Kombination aus
Dichtungen, so dass bei zukünftigen Wartungsarbeiten an der KLE die Hutmutter nachgezogen werden kann.
Wandsteckdose ohne Schalter 3 x Bohrung M40 (2 x oben, 1 x unten)
inkl. 1 x Erweiterungsverschraubung M50
Stecker / Kupplung Ø 19 - 28 mm
Anschlussklemme: Querschnitt Abisolierlänge
der Adern
Wandsteckdose mit Schalter 1 x 2,50 - 25 mm²
(mit Kabelschuh 1 x 35 mm
2
)
13 mm
Wandsteckdose ohne Schalter 1 x 2,50 - 35 mm² 12 mm
Stecker 1 x 4,00 - 16 mm²
(mit Kabelschuh 1 x 25 mm
2
)
12 mm
Flanschsteckdose / Kupplung 1 x 2,50 -
35
mm² 12 mm
Prüfdrehmomente:
Deckelschrauben 2,5 Nm
4,5 Nm
Selbstschneidende Schrauben Größe 4 2,0 Nm
Selbstschneidende Schrauben Größe 5 3,0 Nm
Anschlussschrauben des Schalters 2,0 Nm
Gewicht: (Listenausführung) 3-polig 4-polig 5-polig
Wandsteckdose ohne Schalter GHG 524 4. ca. 5,40 kg ca. 5,50 kg ca. 5,60 kg
Wandsteckdose mit Schalter GHG 524 2. ca. 1,80 kg ca. 1,90 kg ca. 2,00 kg
Stecker GHG 524 7. ca. 0,70 kg ca. 0,75 kg ca. 0,80 kg
Flanschsteckdose GHG 524 8. ca. 1,20 kg ca. 1,30 kg ca. 1,40 kg
Gerätestecker GHG 524 9. ca. 0,80 kg ca. 0,90 kg ca. 1,00 kg
Kupplung GHG 524 3. ca. 1,10 kg ca. 1,20 kg ca. 1,30 kg
Flanschsteckdose
Flanschausschnitt Flanschsteckdose
Gerätestecker
Stecker
Kupplung
Wandsteckdose
mit Schalter
Steckvorrichtungen für Industrieanwendungen 63 A,
3-polig, 4-polig und 5-polig, GHG 524
D
4
2 Sicherheitshinweise
Zielgruppe:
Elektrofachkräfte und geeignet
qualifizierte, unterwiesene Personen
gemäß den nationalen Rechtsvorschriften,
einschließlich der einschlägigen Normen für
elektrische Geräte.
Die Steckvorrichtungen GHG 524 sind nicht
für explosionsgefährdete Bereiche geeignet.
Umbauten oder Veränderungen an den
Steckvorrichtungen sind nicht gestattet.
Sie sind bestimmungsgemäß in unbeschä-
digtem und einwandfreiem Zustand zu
betreiben.
Als Ersatz und zur Reparatur dürfen nur
Originalteile von CEAG verwendet werden.
Reparaturen dürfen nur von CEAG oder
einer qualifizierten Elektrofachkraft in
Übereinstimmung mit national geltenden
Regeln durchgeführt werden.
Vor Inbetriebnahme müssen die Steckvor-
richtungen entsprechend der im Abschnitt 6
genannten Anweisung geprüft werden.
Die Steckvorrichtungen nur mit unbeschä-
digten Steckern betreiben.
Beachten Sie die nationalen Sicherheits-
und Unfallverhütungsvorschriften und die
nachfolgenden Sicherheitshinweise in
dieser Betriebsanleitung, die wie dieser
Text in Kursivschrift gefasst sind!
3 Normenkonformität
Das Betriebsmittel entspricht den aufgeführten
Normen, in der separat beigelegten Konformi-
tätserklärung.
4 Verwendungsbereich
Die Steckvorrichtungen GHG 524 nach
EN/IEC 60309 sind zum Einsatz in schweren
Industriebereichen geeignet!
Die eingesetzten Gehäusematerialien ein-
schließlich der außenliegenden Metallteile
bestehen aus hochwertigen Werkstoffen,
die einen anwendungsgerechten Korrosions-
schutz und Chemikalienresistenz in „normaler
Industrieatmosphäre“ gewährleisten:
- schlagfestes Polyamid
- glasfaserverstärktes Polyester
- Edelstahl AISI 316 L.
Bei einem Einsatz in extrem aggressiver
Atmos phäre, können Sie zusätzliche Infor -
mationen über die Chemikalienbeständigkeit
der eingesetzten Kunststoffe, bei Ihrer
zustän digen Cooper Crouse-Hinds
Niederlassung erfragen.
5 Verwendung/Eigenschaften
Die Steckvorrichtungen GHG 524 dienen
zur Stromversorgung von standortvariablen
Vor-Ort-Steuerungen, elektrischen Anlagen
sowie von beweglichen Maschinen und
Antrieben in industriellen Bereichen. Sie sind
nach IEC bis max. 63A einsetzbar
(siehe technische Daten).
Die Steckvorrichtungen sind generell für den
in der EN/IEC 60309 festgelegten Spannungs-
bereich einsetzbar (z.B. UN 400 V das entspricht
dem
Spannungsbereich 380 - 415 V).
Das am Stecker angeschlossene Betriebs-
mittel muss für die anliegende Netzspan-
nung geeignet sein.
Bild 1: Zur Inbetriebnahme der Steckdose
muss zuerst der Bajonettring Pos. 2 von der
Steckdose Pos. 1 heruntergedreht und
aufgeklappt werden.
Bild 2: Nach dem Stecken des Steckers in
die Steckdose wird, um die Schutzart IP 66
herzustel
len, der Bajonettring des Steckers
Pos. 2 auf die Steckdose bis zum Anschlag
aufgedreht.
Zum Betreiben der Wandsteckdose mit Verrie -
gelungsschalter ist wie folgt vorzugehen:
Bild 1 und Bild 2:
Wie oben beschrieben.
Bild 3: Danach wird der Schalter Pos 3,
eingeschaltet und somit der Stecker in der
Steckdose verriegelt.
Zum Ausschalten und Ziehen des Steckers
aus der Wandsteckdose mit Schalter ist in
umgek
ehrter Reihenfolge vorzugehen.
Nach dem Trennen des Steckers von der
Steckdose ist, um die Schutzart IP 66 herzu-
stellen, die Steckdose mit dem Klappdeckel zu
schließen und mit dem Bajonettring zu sichern.
Das Stecken und Trennen des Steckers von
der Wandsteckdose mit Schalter ist nur im
ausgeschalteten Zustand möglich.
Die Verantwortung hinsichtlich bestim-
mungsgemäßer Verwendung dieser Steck-
vorrichtung liegt allein beim Betreiber.
Nach einem Kurzschluss im Stromkreis
ist die Funktionsfähigkeit zu überprüfen.
Angaben aus Punkt 3 und 4 sind bei
der Verwendung zu berücksichtigen.
Andere als die beschriebenen Anwendun-
gen sind ohne schriftliche Erklärung der
Fa. CEAG nicht zulässig.
Beim Betrieb sind die in der Betriebs-
anleitung unter Punkt 7 genannten
Anweisungen zu beachten.
Die Stecker sind im Freien vorzugsweise mit
der Steckeröffnung (Stiftseite) nach unten
aufzubewahren bzw. mit optional erhältlichen
Steckerschutzkappen zu verschließen.
Maßbilder in mm
Pos. 1
Pos. 2
Pos. 2
Pos. 3
Flanschausschnitt Gerätestecker
Bild 1
Bild 2
Bild 3
Steckvorrichtungen für Industrieanwendungen 63 A,
3-polig, 4-polig und 5-polig, GHG 524
D
5
6 Installation
Für das Errichten / Betreiben sind die
relevanten nationalen Vorschriften sowie die
allgemein anerkannten Regeln der Technik
maßgebend.
6.1 Montage
Die Montage der Wandsteckdosen kann ohne
Öffnen der Gehäuse erfolgen.
Die Wandsteckdosen dürfen bei der Direkt-
montage an der Wand nur an den vorgesehe-
nen Befestigungspunkten eben aufliegen.
Die gewählte Schraube muss der Befestigungs-
öffnung angepasst sein (siehe Maßbilder) und
sie darf d
ie Öffnung nicht beschädigen
(z.B. Verwendung einer Unterlegscheibe). Das
Gerät ist mit mindestens 2 Schrauben diagonal
zu befestigen.
Die Wandsteckdosen und Flanschsteck-
dosen sind so zu montieren, dass die
Stecköffnung nicht nach oben zeigt.
6.2 Öffnen des Gerätes /
Elektrischer Anschluss
Der elektrische Anschluss des Betriebsmittels
darf nur durch Fachpersonal erfolgen.
Die Isolation der Anschlussleitungen muss
bis an die Klemme heranreichen. Der Leiter
selbst darf nicht beschädigt sein.
Die ordnungsgemäß abisolierten Anschlusslei-
tungen der Kabel sind unter Berücksichtigung
einschlägiger Vorschriften anzuschließen.
Der elektrische Anschluss der Stecker erfolgt
wie in Bild 4 und 5 dargestellt:
Der Steckereinsatz, Pos. 2, ist durch lösen der
Befestigungsschrauben, Pos. 3, aus der
Steckerhülse, Pos. 1, herauszunehmen.
Danach kann der Steckereinsatz, Pos. 2, an
den Anschlüssen der Steckerstifte, L1,.... und
PE (Bild 5, Ansicht 1) angeschlossen werden.
Achtung: Bei Verlust der Befestigungs-
schrauben, Pos. 3, Bild 4, sind diese durch
gleichartige Schrauben zu ersetzen, oder
direkt vom Hersteller anzufordern.
Der Zusammenbau erfolgt nach dem Kabel-
anschluss in umgekehrter Reihenfolge.
Der elektrische Anschluss der Gerätestecker
erfolgt wie in Bild 6 bis 8 dargestellt:
Bild 6: Der Steckereinsatz, Pos.2, wird durch
Lösen der zwei Schrauben, Pos. 3, aus dem
Geräteflansch, Pos. 2, entnommen.
Bild 7: Nun können die Anschlussleitungen,
Pos. 4, an den Anschlussklemmen,L1... und PE,
des
Steckereinsatzes, Pos. 2, wie unter
Punkt 6.2 beschrieben, angeschlossen werden.
Bild 8: Zum Schluss wird der Steckereinsatz,
Pos. 2, mit den Formschrauben, Pos. 3, in den
Geräteflansch, Pos. 1, lagerichtig einge-
schraubt.
Die minimal und maximal anschl
ießbaren
Leiterquerschnitte sind zu beachten
(siehe technische Daten).
Al
le Schrauben und/oder Muttern der
Anschluss klemmen, auch die der nicht
benutzten, sind fest anzuziehen.
Die Anschlussklemmen sind für den
Anschluss von Kupferleitern ausgelegt. Bei
der Verwendung von mehr- oder feindrähtigen
Anschlusskabel/-leit
ungen sind die Aderenden
entsprechend den geltenden nationalen
Vorschriften zu behandeln (z.B. Verwendung
von Aderendhülsen).
6.3 Kabel- und Leitungseinführungen
(KLE); Verschlussstopfen
6.3.1 Steckvorrichtung
Für bewegliche Leitungen sind Trompeten-
verschraubungen oder andere geeignete
Einführungen mit zusätzlicher Zugent-
lastung zu verwenden.
Beim Einsatz von KLE mit einer niedrigeren als
der für das Gerät zutreffenden IP-Schutzart,
(siehe Seite 3 technische Daten) wird die
IP-Schutzart des gesamten Gerätes reduziert.
Die für die eingesetzten KLE maßgebenden
Montagerichtlinien sind zu beachten. Nicht
benutzte Einführungsöffnungen sind mit einem
Verschlussstopfen zu verschließen, um die
Schutzart sicherzustellen.
Es ist darauf zu achten, dass bei der Installation
der KLE die für den Leitungsdurchmesser
geeigneten Dichtungseinsätze verwendet
werden. Bei ausschneidbaren Dichtungs-
einsätzen ist sicherzustellen,dass der Einsatz
ordnungsgemäß dem Leitungsdurchmesser
angepasst wird.
Pos. 3 Pos. 3
Pos. 1
Pos. 2
Bild 4
Bild 5
Bild 6
Bild 7
Bild 8
Pos. 1
Pos. 1
Pos. 2
Pos. 3
Pos. 3
Pos. 3
Pos. 3
Pos. 2
Pos. 2 Pos. 1
Pos. 1
Pos. 4
Pos. 2
Pos. 1
Pos. 2
L3
L2
L1
PE
Ansicht 1
Steckvorrichtungen für Industrieanwendungen 63 A,
3-polig, 4-polig und 5-polig, GHG 524
D
6
Zur Sicherstellung der Schutzart sind die
KLE fest anzuziehen.
Bei übermäßigem Anziehen kann die
Schutzart beeinträchtigt werden.
Achtung: Metallflansche, Metallplatten und
Metallverschraubungen müssen in den
Potentialausgleich miteinbezogen werden.
6.3.2 Stecker und Kupplung
Bild 9: Es dürfen generell nur die im Stecker
und der Kupplung vorhandenen Dichteinsätze
verwendet werden. Bei der Installation der
Leitung ist darauf zu achten, dass die für den
Leitungsdurchmesser geeigneten Dichtungs-
einsätze verwendet werden. Nach dem
Anschluss der L
eitung ist die Überwurfmutter
Pos. 2, handfest bis zur Erzielung der Dicht-
wirkung anzuziehen. Danach sind die Schrau-
ben Pos. 4, der Zugentlastung Pos. 3, fest
anzuziehen.
Achtung! Übermäßiges Anziehen kann
die Zugentlastungswirkung negativ
beeinträchtigen.
6.4 Schließen des Gerätes
Zur Sicherstellung der Schutzart sind die
Deckelschrauben, die Schrauben der Stecker
und der Kupplung fest anzuziehen.
Bei übermäßigem Anziehen kann die
Schutzart beeinträchtigt werden.
Alle Fremdkörper sind aus dem Gerät
zu entfernen.
6.5 Inbetriebnahme
Vor Inbetriebnahme des Betriebsmittels sind
die in den einzelnen nationalen Bestimmungen
genannten Prüfungen durchzuführen
. Außerdem ist vor der Inbetriebnahme die
k
orrekte Funktion und Installation des Betriebs-
mittels in Übereinstimmung mit dieser
Betriebsanleitung und anderen anwendbaren
Bestimmungen zu überprüfen.
Vor jedem Stecken des Steckers in die
Steckdose ist dieser auf Beschädigungen zu
überprüfen.
Der Betreiber muss dafür sorgen, dass beim
Betrieb der Steckvorrichtung überall ein
gleiches Erdpotential anliegt.
Unsachgemäße Installation und Betrieb
der Steckvorrichtungen kann zum Verlust
der Gar
antie führen.
7 Instandhaltung / Wartung
Vor Öffnen des Gehäuses Spannungsfrei-
heit sicherstellen oder geeignete Schutz-
maßnahmen ergreifen.
Die erforderlichen Wartungsintervalle sind
anwendungsspezifisch und daher in Abhän-
gigkeit von den Einsatzbedingungen vom
Betreiber festzulegen.
Sollte bei einer Wartung festgestellt werden,
dass Instandsetzungsarbeiten erforderlich
sind, ist Abschnitt 8 dieser Betriebsanleitung
zu beachten.
8 Reparatur / Instandsetzung /
Änderungen
Instandsetzungsarbeiten / Reparaturen dürfen
nur mit CEAG Originalersatzteilen vorgenom-
men werden.
Umbauten oder Änderungen am Betriebs-
mittel sind nicht gestattet.
9 Entsorgung /
Wiederverwertung
Bei der Entsorgung des Betriebsmittels sind die
jeweils geltenden nationalen Abfallbeseitigungs-
vorschriften zu beachten.
Zur Erleichterung der Wiederverwertbarkeit
von Einzelteilen sind Kunststoffteile mit dem
Kennzeichen des verwendeten Kunststoffes
versehen.
Zusätzliche Informationen zur Entsorgung des
Produktes können Sie bei Ihrer zuständigen
Cooper Crouse-Hinds Niederlassung erfragen.
Programmänderungen und -ergänzungen sind
vorbehalten.
Codierung der Spannung und Polzahl
nach IEC
Spannung Farbe h (PE)
2-polig + PE
110 - 130V 50/60Hz gelb 4 Uhr
200 - 250V 50/60Hz blau 6 Uhr
3-polig + PE
200 - 250V 50/60Hz blau 9 Uhr
480 - 500V 50/60Hz schwarz 7 Uhr
380 - 415V 50/60Hz rot 6 Uhr
600 - 690V 50/60Hz schwarz 5 Uhr
3-polig + N + PE
480 - 500V 50/60Hz schwarz 7 Uhr
380 - 415V 50/60Hz rot 6 Uhr
600 - 690V 50/60Hz schwarz 5 Uhr
Bild 9
Anschlussbilder mit Schalter
2-polig + PE 3-polig + PE
3-polig + N + PE
Standard Optional
Pos. 1
Pos. 2
Pos. 3
Pos. 4
Steckvorrichtungen für Industrieanwendungen 63 A,
3-polig, 4-polig und 5-polig, GHG 524
D
7
Plug and socket system for industrial use 63 A,
3-pole, 4-pole and 5-pole, GHG 524
GB
Dimensions in mm
X = fixing dimensions
1 Technical data
1.1 Plug and socket GHG 524
Rated voltage UN up to 690 V, 50/60 Hz
Rated current max. 63 A
Back-up fuse
without thermal protection max. 63 A gG
Switching capacity AC 22
Wall socket with switch 415 V / 63 A
500 V / 63 A
690 V / 63 A
Perm. ambient temperature -20° C to +40° C (catalogue version)
(Special versions permit deviating temperatures)
Perm. storage temperature in original packing -20° C to +40° C
Protection category acc. to IEC/EN 60529
with closed and secured hinged cover
IP 66 (catalogue v
ersion)
Insulation class acc. to IEC/EN 61140 I - is complied with by the devices
Cable entries: (catalogue version)
Wall socket with switch 1 x M50 + 1 x blanking plug M50
suitable cables and test torques of the
pressure screw
Ø Nm
Seal 1+2
1 2
3
min.
max.
(1)
24.0
28.0
6
.0
7.0
Seal 1
1 2
3
min.
max.
(1)
28.0
35.0
5
.0
7.0
Test torque for screw in thread cable entry 7.5 Nm
(1)
The tests of clamping ranges and torque values were performed with metal mandrel. The clamping range can
vary by using cables with different manufacturing tolerances and material properties. Please use a suitable
combination of seals in the intermediate area, so that the cap nut can be tightened in future maintenance
work on the cable entry.
Wall socket without switch 3 x drilling M40 (2 x top, 1 x bottom)
incl. 1 x enlargement gland M50
Plug / Coupler Ø 1
9 - 28 mm
Supply terminal: Cross section Stripped wire
length
Wall socket with switch 1 x 2.50 - 25 mm²
(with cable lugs 1 x 35 mm
2
)
13 mm
Wall socket without switch 1 x 2.50 - 35 mm² 12 mm
Plug 1 x 4.00 - 16 mm²
(with cable lugs 1 x 25 mm
2
)
12 mm
Flange socket / Coupler 1 x 2.50 -
35
mm² 12 mm
Test torques:
Cover screws 2.5 Nm
Terminals 4.5 Nm
Self-cutting screws size 4 2.0 Nm
Self-cutting screws size 5 3.0 Nm
Switch connection screw 2.0 Nm
Weight: (catalogue version) 3-pole 4-pole 5-pole
Wall socket without switch GHG 524 4. approx. 5.40 kg approx. 5.50 kg approx. 5.60 kg
Wall socket with switch GHG 524 2. approx. 1.80 kg approx. 1.90 kg approx. 2.00 kg
Plug GHG 524 7. approx. 0.70 kg approx. 0.75 kg approx. 0.80 kg
Flange socket GHG 524 8. approx. 1.20 kg approx. 1.30 kg approx. 1.40 kg
Inlet GHG 524 9. approx. 0.80 kg approx. 0.90 kg approx. 1.00 kg
Coupler GHG 524 3. approx. 1.10 kg approx. 1.20 kg approx. 1.30 kg
Flange socket
Drilling template for flange sockets
Inlet
Plug
Coupler
Wall socket without switch
Wall socket with switch
8
2 Safety instructions
Target group:
For skilled electricians and suitable
qualified, instructed personnel in
accordance with national legislation,
including the relevant standards.
The GHG 524 plugs and sockets are not
suitable for explosion hazardous areas.
Modifications to the plugs and sockets or
changes of their design are not permitted.
They shall be used for their intended pur-
pose and in perfect and clean condition.
For replacement and repair only genuine
CEAG spare parts shall be used. Repairs
may only be carried out by CEAG or a
qualified electrician in compliance with the
respective national regulations.
Prior to taking the plugs and sockets into
operation, they will have to be checked in
acc. with the instruction as per section 6.
The sockets may only be used in undam-
aged condition.
Observe the national safety rules and regu-
lations for prevention of accidents as well
as the safety instructions included in these
operating instructions and set in italics the
same as this text!
3 Conformity with standards
The apparatus are conform to the standards
specified in the EC-Declaration of conformity,
enclosed separately.
4 Field of application
The plugs and sockets GHG 524, acc to.
IEC/EN 60309 are suitable for use in heavy
industrial areas !
The enclosure materials employed, including
the exterior metal parts, are made of high-
quality materials which ensure a corrosion pro-
tection and resistance to chemical substances
corresponding to the requirements
in a “normal industrial atmosphere”:
- impact resistant polyamide
- glass-fibre reinforced polyester
- special steel AISI 316 L.
When used in extremely aggressive atmos-
phere, you can request additional information
on the chemical resistance of plastics used in
your responsible Cooper Crouse-Hinds branch.
5 Use/Properties
The GHG 524 plugs and sockets are used for
the power supply of local controls with varying
locations, as well as of electrical installations,
mobile machinery and driving gear in industrial
areas. Acc. to IEC they are used up to max. 63 A
(see page 7, technical data).
The plugs and sockets can generally be used
for the voltage range laid down in IEC/EN 60309
(e.g. UN 400V that corresponds to the voltage
range 380-41
5V).
The apparatus connected to the plug shall
be suitable for the applied mains voltage.
Fig. 1: In order to activate the socket, first
the bayonet ring item 2 is to be screwed off
the socket item 1 and to be folded open.
Fig. 2: After pushing the plug into the socket,
the bayonet ring of the plug item 2 is screwed
to its stop onto the socket in order to establish
IP 66 protection category.
For operating the 4-pole wall socket (with
interlocking switch) proceed as follows:
Fig. 1 + fig. 2, as described above.
Fig. 3: The switch item 3 is switched on,
thereby locking the plug in the socket.
Proceed in inverse order to switch off and pull
the plug from the wall socket with switch.
After having removed the plug from the socket,
close the latter with the folding cover and
secure it with the bayonet ring in order to estab
-
lish IP 66 type of protection.
The plug can be pushed int
o the socket and
pulled out of it only whilst the wall socket
with switch is switched off.
The user alone is responsible for the appro-
priate use of this plug and socket system.
After a short in the circuit, the operative-
ness has to be checked.
The data as per point 3 and 4 will have to
be taken into account with the use.
Applications other than described are not
permitted without CEAG’s prior written
consent.
For the operation, the instructions stated in
section 7 of the operating instructions will
have to be observed.
In the open air, the plugs must be kept with
the plug opening (pin side) pointing downwards
or be closed with protective plug caps available
as an optional extra (see general catalogue).
Dimensions in mm
Drilling template for inlets
Item 1
Item 2
Item 2
Item 3
Fig. 1
Fig. 2
Fig. 3
Plug and socket system for industrial use 63 A,
3-pole, 4-pole and 5-pole, GHG 524
GB
9
6 Installation
For the mounting and operation, the
respective national regulations as well
as the general rules of engineering will have
to be observed.
6.1 Mounting
The wall sockets can be mounted without
opening their enclosure.
In case the wall sockets are mounted directly
onto the wall, they may rest evenly only at the
respective fastening points. The chosen screw
shall match the fastening hole (see dimensional
drawing) and it must not damage the hole (e. g.
use of a washer). The device shall be fastened
diagonally with at least 2 screws.
The wall sockets and flange sockets shall
be mounted so that the plug hole does not
point upwards.
6.2 Opening the device /
Electrical connection
The electrical connection of the device may
only be carried out by skilled staff.
The insulation of the conductors shall
reach up to the terminal. The conductor
itself shall not be damaged.
Taking into account the respective regulations,
the properly bared conductors of the cables
shall be connected.
The electrical connection of the plugs is
established as shown in fig. 4 and 5:
The plug insert (item 2, fig. 5) is removed
from the pin bushing (item 1, fig. 5), after the
f
astening screws (item 3, fig. 4) have been
unscrewed.
Thereafter, the plug insert can be connected to
the connections of the plug pins
(see view 1, fig. 5).
Attention: When the fastening screws
(item 3, fig. 4) get lost, they will have
to be replaced by similar screws or to be
ordered directly from the manufacturer.
Assembly is made in inverse order, after the
cable has been connected.
The inlets are electrically connected as
shown in fig. 6 to 8:
Fig. 6: After unscrewing the two screws item 3,
the plug insert item 2 is removed from the
flange item 2.
Fig. 7: Now the connecting leads item 4 can be
connected to the terminal L1... and PE als of
the plug insert item 2 as described in point 6.2.
Fig. 8: Finally, using the self-cutting screws
item 3, the plug insert item 2 is screwed into
the flange, observing its proper position.
The connectible min. and max. conductor
cross-sections shall be observed
(see technical data).
Al
l screws and/or nuts of the supply
terminals, also of those remaining vacant,
shall be tightened down.
The supply terminals are designed for the
connection of copper conductors. If multi- or
fine-wire connecting cables are used, the wire
ends will have to be handled in acc. with the
applicable national and international rules
(e.g. use of sleeves for strands).
6.3
Cable entries (KLE);
blanking plugs
6.3.1
Plug and socket
Flexible cables shall be used with trumpet-
shaped cable glands or other suitable
entries with additional pull-relief.
When using cable entries with a lower IP
protection than that which applies to the device
(see page 7, technical data), the IP protection of
the whole device will be reduced.
The mounting directives applicable to the cable
entries used shall be observed. Unused holes
shall be closed with a blanking plug in order to
establish the minimum protection category.
In case of sealing inserts that are cut out, it
shall be ensured that the insert is properly
adapted to the cable diameter. Care has to
be taken that when fitting the cable entries,
seal
ing inserts appropriate to the cable
diameter are used.
Item 3 Item 3
Item 1
Item 2
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Item 1
Item 1
Item 2
Item 3
Item 3
Item 3
Item 3
Item 2
Item 2 Item 1
Item 1
Item 4
Item 2
Item 1
Item 2
L3
L2
L1
PE
View 1
Plug and socket system for industrial use 63 A,
3-pole, 4-pole and 5-pole, GHG 524
GB
10
In order to ensure the required minimum
protection category, the cable glands are
to be tightened down.
Overtightening might impair the protection
category.
Attention: Metal flanges, metal plates and
metal cable glands shall be included in the
equipotential earth connection.
6.3.2 Plug and coupler
Fig. 9: In general, only the sealing inserts fitted
in the plug and coupler may be used. When
mounting the cable, attention has to be paid
that sealing inserts matching the cable diameter
be used. After having connected the cable, the
coupling ring item 2 is to be screwed fingertight
until the sealing effect is obtained. Then the
screws item 4 of the pull-relief, item 3, are to
be tightened down.
Mind! Overtightening might impair the
pull-relief effect!
6.4 Closing the device
In order to ensure the required minimum
protection category, the cover screws, the
screws of the plug and of the coupler shall
be tightened down.
Overtightening might impair the protection
category.
Any foreign matter shall be removed from
the device.
6.5 Taking into operation
Prior to taking the apparatus into operation,
the tests specified in the relevant national
regulat
ions shall be carried out.
Apart from that, the correct functioning and
installation of the apparatus in accordance with
these operating instructions and other
applicable regulations
will have to be checked.
Check the plug for any damages before putting
it in the socket.
The user must ensure that a uniform equipoten-
tial earth applies throughout when the plug and
sock
et system is operated.
The inappropriate installation and operation
of the plugs and sockets can entail the loss
of warranty.
7 Maintenance / Servicing
Before opening the enclosure, make sure
that the device is disconnected from the
voltage, or take appropriate protective
measures.
The required maintenance intervals depend
on the specific application and will therefore
have to be determined by the user dependent
on the conditions of use.
If during servicing, repairs prove to be
necessary, section 8 of these operating
instructions will have to be observed.
8 Repair / Overhaul /
Modifications
Repairs and overhaul may only be carried out
with genuine CEAG spare parts.
Modifications to the device or changes of
its design are not permitted.
9 Disposal / Recycling
When the apparatus is disposed of, the
respective national regulations on waste
disposal will have to be observed.
In order to facilitate the recycling of individual
components, plastic parts are provided with
the identification mark of the plastic material
used.
In case of disposal you can obtain additional
information from your Cooper Crouse-Hinds
branch.
Subject to modifications or supplement of the
product range.
Code for voltage and No. of poles
acc. to IEC
Voltage Colour h (PE)
2-pole + PE
110 - 130V 50/60Hz yellow 4 h
200 - 250V 50/60Hz blue 6 h
3-pole + PE
200 - 250V 50/60Hz blue 9 h
480 - 500V 50/60Hz black 7 h
380 - 415V 50/60Hz red 6 h
600 - 690V 50/60Hz black 5 h
3-pole + N + PE
480 - 500V 50/60Hz black 7 h
380 - 415V 50/60Hz red 6 h
600 - 690V 50/60Hz black 5 h
Fig. 9
Contact arrangement with switch
2-pole + PE 3-pole + PE
3-pole + N + PE
Standard Optional
Item 1
Item 2
Item 3
Item 4
Plug and socket system for industrial use 63 A,
3-pole, 4-pole and 5-pole, GHG 524
GB
11
Fiches et prises de 63 A, à 3 pôles, 4 pôles et 5 pôles,
pour utilisation industrielle, GHG 524
F
Dimensions en mm
X = dimensions de fixation
1 Caracteristiques techniques
1.1 Fiche et prise GHG 524
Tension nominale UN jusqu’à 690 VCA, 50/60 Hz
Courant nominal 63 A au maxi
Fusible maximal placé en amont:
sans protection thermique 63A gG au maxi
Puissance de cupre AC 22
Prise murale avec interrupteur 415 V / 63 A
500 V / 63 A
690 V / 63 A
T
empérature ambiante admissible -20° C à +40° C (standard catalogue)
(En cas de modèles spéciaux d’autres températures possibles)
Température de stockage dans l’emballage original
-20°C à +40°C
Indice de protection selon CEI/EN 60529,
avec le couvercle rabattant fermé et arrêté
et les dispositifs dûment enfichés
IP 66 (standard catalogue)
Classe d
’isolation selon CEI/EN 61140 I - est remplie par les dispositifs
Entrée de câble: (standard catalogue)
Prise murale avec interrupteur
1x M50 +1x bouchon de fermeture
câbles appropriés et couples d’essai de la vis
de pression
Ø Nm
Garnit
ure 1+2
1 2
3
min.
max.
(1)
24,0
28,0
6
,0
7,0
Garniture 1
1 2
3
min.
max.
(1)
28,0
35,0
5
,0
7,0
Couple d' essai pour l’entrée de câble 7,5 Nm
(1)
Les tests des plages de serrage et les valeurs de couple de serrage ont été réalisés avec un mandrin
métallique. La plage de serrage peut varier légèrement selon le type de câble et les propriétés des matériaux
utilisés. Pour les plages de serrage intermédiaires, veuillez utiliser des garnitures d’étanchéité qui laisseront la
possiblité de resserrer le chapeau du presse étoupe lors de futures opérations de maintenance.
Prise murale sans interrupteur 3 x alésage M40 (2 x en bas /1 x en haut) avec
1 x presse-étoupe d'élargissement M50
Fiche / Coupleur Ø 1
9 - 28 mm
Borne de connexion: Section transv.
Longueur dénu-
dée des fils
Prise murale avec interrupteur 1 x 2,50 - 25 mm²
(avec cosses de câble 1 x 35 mm²)
13 mm
Prise murale sans interrupteur 1 x 2,50 - 35 mm² 12 mm
Connexion de la fiche 1 x 4,00 - 16 mm²
(avec cosses de câble 1 x 25 mm²)
12 mm
Prise encastrable / Coupleur 1 x 2,50 -
35
mm² 12 mm
Torques d’essai:
Vis de couvercle 2,5 Nm
Bornes de connexion 4,5 Nm
Vis auto-taraudeuse taille 4 2,0 Nm
Vis auto-taraudeuse taille 5 3,0 Nm
Vis de connexion de la interrupteur 2,0 Nm
Poids: (standard catalogue) 3-pôles 4-pôles 5-pôles
Prise murale avec interrupteur GHG 524 4. env. 5,40 kg env. 5,50 kg env. 5,60 kg
Prise murale avec interrupteur GHG 524 4. env. 1,80 kg env. 1,90 kg env. 2,00 kg
Fiche GHG 524 7. env. 0,70 kg env. 0,75 kg env. 0,80 kg
Prise encastrable GHG 524 8. env. 1,20 kg env. 1,30 kg env. 1,40 kg
Connecteur GHG 524 9. env. 0,80 kg env. 0,90 kg env. 1,00 kg
Coupler GHG 524 3. env. 1,10 kg env. 1,20 kg env. 1,30 kg
Prise encastrable
Gabarit de perçage pour prise encastrable
Connecteur
Fiche
Coupleur
Prise murale sans interrupteur
Prise murale avec interrupteur
12
2 Consignes de sécurité
Groupe cible:
Pour les électriciens qualifiés et les
personnels ayant reçu les formations
adéquates, conformément à la législation
nationale en vigueur.
Les fiches et prises du type GHG 524 ne
doivent pas être utilisées en atmosphère
explosive.
Il n’est pas admis de transformer ou de
modifier les fiches et prises. Elles ne doivent
être employées que pour la fonction qui leur
est dévolue et qu’en parfait état de propreté
et de fonctionnement.
Seules des pièces de rechange homologuées
d’origine CEAG devront être utilisées
comme remplacement et pour des répara-
tions.Des réparations ne devront être
ex
écutées que par CEAG ou par un électri-
cien qualifié en conformité avec la règlemen-
tation nationale en vigueur.
Avant leur mise en service, les fiches et
prises doivent être vérifiées selon l’instruc-
tion donnée dans la section 6.
Les pr
ises ne doivent être utilisées qu’avec
les fiches y appartenants et en parfait état.
Respectez les prescriptions nationales de
sécurité et de prévoyance contre les
accidents ainsi que les consignes de sécurité
qui suivent dans ce mode d’emploi et qui
sont mises en italique comme ce texte!
3 Conformité avec les normes
Les Appareils sont conformes aux normes
reprises dans la déclaration de conformité,
jointe séparément.
4 Domaine d’utilisation
Les fiches et prises selon CEI/EN 60309, du
type GHG 524, conviennent à l’emploi en
atmosphère industrielle!
Pour l’enveloppe, y compris les pièces métal-
liques extérieures, des matières de qualité
supérieure ont été employées qui assurent
une protection appropriée contre la corro-
sion et une résistance contre des agents
chimiques en “atmosphère industrielle
normale”:
- polyamide résistant au choc
- polyester renforcé par fibre de verre
- acier spécial AISI 316.
En cas d‘utilisation en atmosphère extrème-
ment corrosive, vous pouvez obtenir des
informations complémentaires sur la résistance
chimique des plastiques utilisés chez la
succursale Cooper Crouse-Hinds de votre
région.
5 Utilisation / Propriétés
Les fiches et prises GHG 524 servent à
l’alimentation en courant de réglages auto-
matiques en place à emplacement variable
et d’installations électriques ainsi que de
machines et de mécanismes de commande
mobiles en atmosphère industrielle. Elles
peuvent être exploitées jusqu’à 63A au maxi
selon CEI (voir caractéristiques techniques).
Les prises et fiches sont utilisables dans les
fourchettes de tension comprises dans la
norme CEI/EN 60309 (par exemple, UN 400V
appartient à la fourchette 380 - 415V).
L’ appareil connecté à la fiche doit être
adapté à la tension du réseau corres-
pondant.
Fig. 1: Pour la mise en circuit de la prise, il faut
d’abord dévisser l’anneau à baïonnette, pos. 2
de la prise, pos. 1, et le déplier.
Fig. 2: Après avoir en fiché la fiche dans la prise,
l’anneau à baïonnette, de la fiche, pos. 2, est
vissé jusqu’à sa butée sur la prise afin d’établir
l’indice de protection IP 66.
Pour la mise en circuit de la prise murale avec
interrupteur de verouillage procédez comme
suit:
Fig. 1 et fig. 2, comme décrit ci-dessus.
Fig. 3: Puis, l’interrupteur pos. 3 est enclenché
et, par conséquent, la fiche est bloquée dans la
prise.
Pour la mise hors circuit et pour retirer la fiche
de la prise murale à 4 pôles, procédez dans
l’ordre inverse.
Après avoir séparé la fiche de la prise, celle-ci
doit être fermée avec le couvercle à charnière
et bloquée avec l’anneau à baïonnette, afin
d’établir l’indice de protection IP 66.
La fiche ne peut être enfichée dans la prise
ou retirée de celle-ci que lorsque la prise
est mise hors circuit.
Seul l’utilisateur est responsable de l’em-
ploi comme prévu de cette fiche et prise.
Après un court-circuit dans le circuit, la
capabilité de fonctionner doit être vérifiée.
Pour l’emploi, les consignes des sections 3
et 4 devront être respectées.
Des emplois autres que ceux décrits ne
sont admis qu’avec le consentement par
écrit de la part de CEAG.
Lors de l
exploitation, les instructions selon
point 7 de ce mode d’emploi doivent être
respectées.
En plein air, les fiches doivent être gardées avec
leur ouverture (côté des broches) vers le bas.
A l’option, elles peuvent être fermées avec les
capuchons protecteurs pour la fiche qui sont
disponibles sur demande (voir catalogue
général).
Dimensions en mm
Gabarit de perçage pour connecteur
Pos. 1
Pos. 2
Pos. 2
Pos. 3
Fig, 1
Fig, 2
Fig, 3
Fiches et prises de 63 A, à 3 pôles, 4 pôles et 5 pôles,
pour utilisation industrielle, GHG 524
F
13
6 Installation
Pour l’installation et l’exploitation d’appareils
électriques la règlementation nationale en
vigueur ainsi que les règles de la technique
généralement reconnues devront être
respectées.
6.1 Montage
Le montage des prises murales peut se faire
sans ouvrir l’enveloppe.
En cas de montage directement au mur, les
prises murales ne doivent reposer au niveau
du mur qu’en les points de fixation prévus. La
vis choisie doit cor
respondre au trou de fixation
(voir plan coté) et elle ne doit pas avarier
l’ouverture (par ex. emploi d’une rondelle).
Le dispositif doit être fixé en diagonale avec
au moins deux vis.
Le montage de la prise murale et de la
prise à bride doit se faire de sorte que
l’ouverture d’enfichage ne soit pas dirigée
vers le haut.
6.2 Ouverture du dispositif /
Raccordement électrique
Le raccordement électrique du dispositif ne doit
se faire que par du personnel qualifié.
L’isolation doit couvrir le conducteur
jusqu’à la borne. Le conducteur lui-même
ne doit pas être endommagé.
En tenant compte des règlements respectifs,
les conducteurs dûment dénudés des câbles
sont raccordés.
Le raccordement électrique des fiches se
fait comme montré dans les figures 4 et 5:
L
es vis de fixation (pos. 3, fig. 4) de l’insert de
la fiche (pos. 2, fig. 5) sont desserrées pour le
sortir de l’alvéole.
Puis, l’insert peut être raccordé aux connexions
des contacts L1, ....
et PE mâles (voir vue 1, fig. 5).
Attention: En cas de perte des vis de
fixation (pos. 3, fig. 4) celles-ci doivent être
remplacées par des vis similaires ou être
demandées au fabricant.
L'assemblage est réalisé par la connexion du
câble dans l'ordre inverse.
Le raccordement électrique des connecteurs
se fait comme montré dans les figures 6 à 8:
Fig. 6: Après avoir dévissé les deux vis pos. 3,
l’insert de commutation pos. 2 est sorti de la
bride pos. 2.
Fig. 7: Puis, les fils d’alimentation pos. 4
peuvent être raccordés aux bornes de l’insert
de commutation pos. 2, comme décrit sous
point 6.2.
Fig. 8: Enfin, l’insert de commutation pos. 2 est
vissé dans la bride pos. 1 au moyen des vis
auto-taraudeuses pos. 3 tout en respectant sa
position correcte.
Les sections minimales et maximales
admissibles des conducteurs doivent être
respectées (voir caractéristiques techniques).
Toutes les vis et/ou écrous des bornes de
connexion, aussi celles des bornes non
utilisées, doivent être serrées à fond.
Les bornes sont prévues pour le raccordement
de conducteurs en cuivre. En cas d’utiliser des
câbles de connexion multifilaires ou à fils de
faible diamètre, les bouts de fil doivent être
traités selon la règlementation nationale et
internationale y applicable (par ex. emploi des
embouts).
6.3 Entrées de câble (KLE);
bouchons de fermeture
6.3.1 Fiche et prise
Pour des câbles flexibles il faudra utili-
ser des presses-étoupes à trompette ou
d’autres entrées convenables avec dé-
charge de traction supplémentaire.
Lorsque des entrées de câble avec un indice de
protection IP inférieur à celui du dispositif sont
employées (voir page 11), l’indice de protection
IP de l’ensemble sera réduit.
Les directives pour le montage applicables aux
entrées de câble montées doivent être
respectées. Des ouvertures d’entrée non
utilisées doivent être fermées avec un bouchon
de fermeture pour établir l’indice de protection.
Lors du montage des entrées de câble il faudra
veiller à ce que des garnitures d’étanchéité
correspondant au diamètre du câble soient
utilisées. En cas de garnitures qui doivent être
coupées sur mesure, il faudra faire attention à
ce que la garniture soit adaptée au diamètre du
câble.
Pos. 3 Pos. 3
Pos. 1
Pos. 2
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Pos. 1
Pos. 1
Pos. 2
Pos. 3
Pos. 3
Pos. 3
Pos. 3
Pos. 2
Pos. 2 Pos. 1
Pos. 1
Pos. 4
Pos. 2
Pos. 1
Pos. 2
L3
L2
L1
PE
Voir 1
Fiches et prises de 63 A, à 3 pôles, 4 pôles et 5 pôles,
pour utilisation industrielle, GHG 524
F
14
Les entrées de câble doivent être serrées à
fond pour maintenir l’indice de protection.
Au cas où elles seraient forcées, cela pourrait
être nuisible à l’indice de protection.
Attention: les plaques à brides métalliques,
les plaques de fond métalliques et les
presse-étoupe métalliques doivent être
reliés au même potentiel.
6.3.2 Fiche et coupleur
Fig. 9: Généralement, les garnitures pourvues
dans la fiche et coupleur doivent être utilisées.
Lors du montage du câble, il faut faire attention
à ce que des garnitures convenables pour le
diamètre du câble soient employées. Après
avoir connecté le câble, la collerette de fixation,
pos. 2, doit être vissée à la main jusqu’à ce que
l’étanchéité soit assurée. Puis, les vis, pos. 4,
de la pince de décharge de traction, pos. 3,
doivent être serrées à fond.
Attention! Un serrage excessif peut nuir à
l’effet de décharge de traction.
6.4 Fermeture du dispositif
Les vis du couvercle, de la fiche et du
prolongateur doivent être serrées à fond afin
d’assurer l’indice de protection minimum
requis.
Au cas où elles seraient forcées, cela pour-
rait être nuisible à l’indice de protection.
Tout corps étranger doit être ôte du
dispositif.
6.5 Mise en service
Avant la mise en service du matériel, les
vérifications spécifiées dans les règlements
nationaux individuels devront être exécutées.
De plus, il faudra vérifier son fonctionnement et
installation corrects en conformité avec ce
mode d’emploi et avec d’autres règlements y
applicables.
Chaque fois que la fiche est enfichée dans la
prise, elle devra d’abord être vérifiée pour des
avaries.
L’utilisateur doit veiller à ce que le même
potentiel terrestre soit appliqué en tout lieu.
L’installation et l’exploitation inadéquates
des fiches et prises peut entraîner la perte
de la garantie.
7 Maintien / Entretien
Avant d’ouvrir l’enveloppe, débrancher
le dispositif de la tension ou prendre des
mesures préventives appropriées.
Les intervalles de service requis dépendent
de l’emploi spécifique et devront donc être
fixés par l’utilisateur en tenant compte des
conditions d’exploitation.
Si, lors d’un entretien, on constate que des
travaux d’entretien sont nécessaires, il faudra
suivre le point 8 de ce mode d’emploi.
8 Réparation / Remise en état
Des réparations ne doivent être exécutées
qu’à l’aide de pièces de rechange d’origine
CEAG.
Il n’est pas permis de transformer ou de
modifier ce matériel.
9 Évacuation des déchets /
Recyclage
Lors de l’évacuation de ce matériel électrique,
la règlementation nationale respective en
vigueur devra être respectée.
Pour faciliter la réutilisation des composants
individuels, des pièces en matière plastique
sont repérées de la marque distinctive de la
matière plastique employée.
En cas d'élimination, vous pouvez obtenir des
informations supplémentaires auprès de votre
branche Cooper Crouse-Hinds.
Sous réserve de modification ou de supplément
de cette série de produits.
Codage de la tension et du nombre
de pôles selon CEI
Disposition des contacts avec interrupteur
2-pôles + PE 3-pôles + PE
3-pôles + N + PE
Standard Optional
Fig. 9
Pos. 1
Pos. 2
Pos. 3
Pos. 4
Tension Couleur h (PE)
2 pôles + PE
110 - 130V 50/60Hz jaune 4 h
200 - 250V 50/60Hz bleu 6 h
3 pôles + PE
200 - 250V 50/60Hz bleu 9 h
480 - 500V 50/60Hz noir 7 h
380 - 415V 50/60Hz rouge 6 h
600 - 690V 50/60Hz noir 5 h
3 pôles + N + PE
480 - 500V 50/60Hz noir 7 h
380 - 415V 50/60Hz rouge 6 h
600 - 690V 50/60Hz noir 5 h
Fiches et prises de 63 A, à 3 pôles, 4 pôles et 5 pôles,
pour utilisation industrielle, GHG 524
F
15
Notizen / Notes / Remarques
Eaton is a registered trademark.
All trademarks are property
of their respective owners.
Eaton is dedicated to ensuring that reliable, efficient
and safe power is available when it’s needed most. With
unparalleled knowledge of electrical power management
across industries, experts at Eaton deliver customized,
integrated solutions to solve our customers’ most critical
challenges.
Our focus is on delivering the right solution for the appli-
cation. But, decision makers demand more than just
innovative products. They turn to Eaton for an unwavering
commitment to personal support that makes customer
success a top priority. For more information, visit
www.eaton.com/electrical.
Changes to the products, to the information contained in this
document, and to prices are reserved; so are errors and omissions.
Only order confirmations and technical documentation by Eaton is
binding. Photos and pictures also do not warrant a specific layout or
functionality. Their use in whatever form is subject to prior approval
by Eaton. The same applies to Trademarks (especially Eaton, Moeller,
and Cutler-Hammer). The Terms and Conditions of Eaton apply, as
referenced on Eaton Internet pages and Eaton order confirmations.
Cooper Crouse-Hinds GmbH
Neuer Weg-Nord 49
69412 Eberbach
www.crouse-hinds.de
© 2017 Eaton
All Rights Reserved
Printed in Germany
dd
Publication No.
GHG 510 7003 P0003 D/GB/F (i)
Auflage / 13.2017 / CS
CZ: "Tento návod k použití si m žete vyžádat
ve
svém mate ském jazyce u p íslušného
zastoupení spole nosti Cooper Crouse-
Hinds/CEAG ve vaší zemi."
DK: "Montagevejledningen kan oversættes til
andre EU-sprog og rekvireres hos Deres
Cooper Crouse-Hinds/CEAG leverandør"
E: "En caso necesario podrá solicitar de su
representante Cooper Crouse-Hinds/CEAG
estas instrucciones de servicio en otro idioma
de la Union Europea"
EST: "Seda kasutusjuhendit oma riigikeeles
võite küsida oma riigis asuvast asjaomasest
Cooper Crouse-Hindsi/CEAG esindusest."
FIN: "Tarvittaessa tämän käyttöohjeen käännös
on saatavissa toisella EU:n kielellä Teidän
Cooper
Crouse-Hinds/CEAG - edustajaltanne"
GR:
Cooper Crouse-
Hinds/CEAG"
H: "A kezelési útmutatót az adott ország
nyelvén a Cooper Crouse-Hinds/CEAG cég
helyi képviseletén igényelheti meg."
I: "Se desiderate la traduzione del manuale
operativo in un´altra lingua della Comunit à
Europea potete richiederla al vostro
rappresentante Cooper Crouse-Hinds/CEAG"
LT: Šios naudojimo instrukcijos, išverstos
J su
gimt
j kalb , galite pareikalauti atsakingoje
"Cooper Crouse-Hinds/CEAG" atstovyb
je savo
šalyje.
LV: "Šo ekspluat
cijas instrukciju valsts valod
varat piepras t j su valsts atbild gaj Cooper
Crouse-Hinds/CEAG p
rst vniec b ."
M: Jistg
u jitolbu dan il-manwal fil-lingwa
nazzjonali tag
hom ming and ir-rappre entant
ta' Cooper Crouse Hinds/CEAG f'pajji
hom.
NL: "Indien noodzakelijk kan de vertaling van
deze gebruiksinstructie in een andere EU-taal
worden opgevraagd bij Uw Cooper Crouse-
Hinds/CEAG - vertegenwoordiging"
P: "Se for necessária a tradução destas
instruções de operação para outro idioma da
União Europeia, pode solicita-la junto do seu
representante Cooper Crouse-Hinds/CEAG"
PL: Niniejsz
instrukcj obs ugi w odpowiedniej
wersji j
zykowej mo na zamówi
w
przedstawicielstwie firmy Cooper-Crouse-
Hinds/CEAG na dany kraj.
S: "En översättning av denna montage- och
skötselinstruktion till annat EU - språk kan vid
behov beställas från Er Cooper Crouse-
Hinds/CEAG- representant"
SK: "Tento návod na obsluhu Vám vo Vašom
rodnom jazyku poskytne zastúpenie spolo
nosti
Cooper Crouse-Hinds/CEAG vo Vašej krajine."
SLO: "Navodila za uporabo v Vašem jeziku
lahko zahtevate pri pristojnem zastopništvu
podjetja Cooper Crouse-Hinds/CEAG v Vaši
državi."
RUS:
"
При необходимости, вы можете запрашивать
перевод данного руководства на другом языке
ЕС или на русском от вашего
Cooper Crouse-Хиндс / CEAG - представителей."
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Eaton Crouse-hinds series Operating Instructions Manual

Taper
Operating Instructions Manual
Ce manuel convient également à