ELICA EAS430SS Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation

Ce manuel convient également à

1
Use, Care, and
Installation Guide
Guide
d’utilisation,
d’entretien et
d’installation
Guía de
instalación, uso y
mantenimiento
READ AND SAVE THESE
INSTRUCTIONS
LISEZ CES
INSTRUCTIONS ET
CONSERVEZ-LES
LEA Y CONSERVE
ESTAS INSTRUCCIONES
LIB0168796
Printed in Mexico
05/20
Model: EAS430SS
2
ENGLISH
Contents
Important safety notice ................................................................................................................................................................................................ 3
List of materials ............................................................................................................................................................................................................... 4
Parts supplied ............................................................................................................................................................................................................. 4
Parts not supplied ..................................................................................................................................................................................................... 4
Dimensions and clearances ........................................................................................................................................................................................ 5
Venting requirements ................................................................................................................................................................................................... 5
Electrical requirements ................................................................................................................................................................................................ 6
Installation ......................................................................................................................................................................................................................... 7
Install range hood ...................................................................................................................................................................................................... 9
Conect vent system ................................................................................................................................................................................................. 10
Complete the installation ....................................................................................................................................................................................... 10
Description of the hood ............................................................................................................................................................................................... 10
Control ................................................................................................................................................................................................................................ 10
Maintenance ...................................................................................................................................................................................................................... 10
Available accessories .................................................................................................................................................................................................... 11
Warranty ............................................................................................................................................................................................................................. 12
APPROVED FOR RESIDENTIAL APPLIANCES
FOR RESIDENTIAL USE ONLY
READ AND SAVE THESE INSTRUCTIONS
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT: Save these Instructions for the Local Electrical Inspector’s use.
INSTALLER: Please leave these Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
Safety Warning: Turn o power circuit at service panel and lock out panel, before wiring this appliance.
Requirement: 120 V AC, 60 Hz. 15 or 20 A Branch Circuit.
3
I
IMPORTANT SAFETY NOTICE
A. Do not operate any fan with a damaged cord or plug.
Discard fan or return to an authorized service facility for
examination and/or repair.
B. Do not run cord under carpeting. Do not cover cord with
throw rugs, runners, or similar coverings. Do not route cord
under furniture or appliances. Arrange cord away from
trac area and where it will not be tripped over.
I CAUTION
FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO
EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS OR
VAPOURS.
IWARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
C. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
D. Before servicing or cleaning the unit, switch power o
at service panel and lock service panel disconnecting
means to prevent power from being switched on
accidentally.
When the service cannot be locked, securely fasten a pro-
minent warning device, such as a tag, to the service panel.
E. Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
& standards, including fire-rated construction.
F. Sucient air is needed for proper combustion and
exhausting of gases through the flue (Chimney) of fuel
burning equipment to prevent back- drafting.
Follow the heating equipment manufacturers guideline
and safety standards such as those published by the
national fire protection association (NFPA), the american
society for heating, refrigeration and air conditioning
engineers (ASHRAE), and the local code authorities.
G. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
H. Ducted fans must always be vented to the outdoor.
I CAUTION
To reduce risk of fire and to properly exhaust air, be sure to
duct air outside - do not vent exhaust air into spaces within
walls, ceilings, attics, crawl spaces, or garages.
IWARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT
WORK.
Install this hood in accordance with all requirements specified.
IWARNING
To reduce the risk of fire or electric shock, do not use this
hood with any external solid state speed control device.
IWARNING
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE.
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
flambeing food (I.e. Crepes Suzette, Cherries Jubilee,
Peppercorn Beef Flambe’).
c) Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate
for the size of the surface element.
IWARNING
TO REDUCE THE RISK OF INJURY TO PERSONS, IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING:
a
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet,
or other metal tray, then turn o the gas burner or the
electric element. BE CAREFUL TO PREVENT BURNS. If the
flames do not go out immediately, EVACUATE AND CALL
THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN - you may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels -
a violent steam explosion will result.
d) Use an extinguisher ONLY if:
1) You know you have a class ABC extinguisher, and
you already know how to operate it.
2) The fire is small and contained in the area where it
started.
3) The fire department is being called.
4) You can fight the fire with your back to an exit.
a
Based on “Kitchen Fire Safety Tips” published by NFPA.
I CAUTION
Automatically Operated Device - To Reduce The Risk Of
Injury Disconnect From Power Supply Before Servicing.
OPERATION
Always leave safety grills and filters in place. Without these
components, operating blowers could catch onto hair, fingers
and loose clothing.
The manufacturer declines all responsibility in the event of
failure to observe the instructions given here for installation,
maintenance and suitable use of the product.
The manufacturer further declines all responsibility for injury
due to negligence and the warranty of the unit automatically
expires due to improper maintenance.
4
LIST OF MATERIALS
Removing the packaging.
I CAUTION
Remove carton carefully, Wear gloves to protect against sharp edges.
I WARNING
Remove the protective film covering the product before putting into operation.
Supplied Part Pieces Supplied Part Pieces
Hood assembly
1
Damper
1
Metal grease filters
2
30” x 12” (76.2 cm x 30.5 cm) face panel
1
Mounting brackets
2
4.5x13 mm
10
Metal spacers
6
4.2x15 mm
2
Torx #10 adapter
1
3.5x9.5 mm
4
plastic washers
8
4.2x19 mm
8
metal washers
8
3.5x9.5 mm
2
Parts no supplied
Tools/Materials required
Level
Drill
1
8” (3.0 mm) drill bit
Pencil
Pliers
Tape measure or ruler
Caulking gun and weatherproof caulking compound
Flat-blade screwdriver
Phillips screwdriver
Saber or keyhole saw
Metal snips
Vent clamps
Parts needed
• 6” (15.2 cm) round metal vent system
For vented installations, you will need
• 1 wall or roof cap
For non-vented (recirculating) installations, you will also
need:
• Recirculation Kit. See the “Available accessories” section.
Location requirements:
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer’s responsibility to comply with installation clearances
specified on the model/serial rating plate. The model/serial
rating plate is located inside the liner behind the filter on the
left wall of the range hood.
Range hood location should be away from strong draft areas,
such as windows, doors, and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance. Consult your
cooktop/ range manufacturer installation instructions before
making any cutouts.
This range hood is recommended for use with cooktops with
a maximum total rating of 65,000 BTUs or less.
Grounded electrical outlet is required. See “Electrical Requi-
rements” section.
The range hood is factory set for vented installations through
the roof or wall. For non-vented (recirculating) installations
see “Non- Vented (recirculating) Installation Through the
Soffit/Cabinet” in the “Prepare Location” section.
Recirculation Kit Part is available from your dealer or an authorized
parts distributor. All openings in ceiling and wall where range
hood will be installed must be sealed.
For mobile home installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.
®TORX is a registered trademark of Saturn Fasteners, Inc.
5
LOCATION REQUIREMENTS
Product dimensions
A
I
H
F
G
E
D
C
B
Model
EAS430SS
A 3/8” (10 mm)
B 30” (76.2 cm) or 36” (91.4 cm)
C 26” (66.1 cm)
D 2” (5.1 cm) or 5”(12.7 cm)
E 10
3
4” (27.4 cm)
F 3/4” (19 mm)
G 11
7
8” (30.2 cm) or 17
7
8” (45.4 cm)
H 9
1
8” (23.1 cm)
I 13
5
8” (33.7 cm)
For gas and electric ranges installation: Mount this hood so
that the bottom edge is at minimum 30”(76.2 cm) above the
cooking surface.
Installation clearances
F
A
B
C
D
E
A. 12” (30.5 cm) min. upper
cabinet height
B. 30” (76.2 cm) or 36” (91.4
cm) cabinet opening width*
C. 24” (61.0 cm) min. from elec-
tric cooking surface, 27” (68.6
cm) min. from gas cooking
surface, 36” (91.4 cm) sugges-
ted max. bottom of cabinet to
cooking surface
D. 12” (30.48 cm) cabinet opening
depth*
E. 15” (38.1 cm) min. clearance
upper cabinet to countertop
F. 36” (91.4 cm) base cabinet
height
*NOTE: 30” (76.2 cm) cabinet width can be 12” (30.5 cm)
deepor 18” (45.7 cm) deep cabinets.
36” (91.4 cm) cabinet width requires 18” (45.7 cm)
deep cabinets.
For 18” (45.7 cm) deep cabinets, an optional Face Panel
Rear Extension (30” [76.2 cm]) must be purchased sepa-
rately. See the “Available accessories” section to order.
Venting requirements
Vent system must terminate to the outdoors, except for no
vented (recirculating) installations.
Do not terminate the vent system in an attic or other
enclosed area.
Do not use a 4” (10.2 cm) laundry-type wall cap.
Rigid metal vent is recommended. Plastic or metal foil
vent is not recommended. The length of vent system and
number of elbows should be kept to a minimum to provide
ecient performance.
For the most ecient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24” (61 cm) of straight
vent between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps to seal all joints in the vent system.
The vent system must have a damper.
Use caulking to seal exterior wall or roof opening around
the cap.
The size of the vent should be uniform.
6
Cold weather installations
An additional back draft damper non return valve should be
installed to minimize backward cold air flow and a thermal
break should be installed to minimize conduction of outside
temperatures as part of the vent system. The damper non
return valve should be on the cold air side of the thermal
break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup air
Local building codes may require the use of makeup air sys-
tems when using ventilation systems with greater than spe-
cified CFM of air movement. The specified CFM varies from
locale to locale. Consult your HVAC professional for specific
requirements in your area.
Venting methods
This range hood is factory set for venting through the roof
or through the wall. You can apply the recirculating venting
method by purchasing the Recirculation Kit. The vent system
needed for installation is not included.
A 6” (15.2 cm) round vent system is recommended.
Roof venting Wall venting
A
B
A. 6” (15.2 cm) vent through
the roof
B. Roof cap
A
B
A. 6” (15.2 cm) vent through
the wall
B. Wall cap
Calculate Vent System Length
The recommended vent system is 6” (15.2 cm) round vent
with a maximum length of 35 ft (10.7 m). For the best perfor-
mance, use no more than three 90° elbows.
To calculate the length of the system, add the equivalent feet
(meters) for each of the vent pieces used in the system.
Vent piece 6” (15.2 cm)
45° elbow 2.5 ft (0.8 m)
90° elbow 5.0 ft (1.5 m)
Non-Vented (recirculating) Installations
Through the Soffit/Cabinet
If it is not possible to vent cooking fumes and vapors to the
outside, the range hood can be used in the non-vented
(recirculating) version, using a charcoal filter. Recirculation
Kit is available from the dealer or an authorized parts distributor.
Through Cabinet Through Soffit
A
B
D
E
F
G
I
H
A
B
C
D
E
F
G
A. Ceiling
B. Vent cover
C. Sot
D. 6” (15.2 cm) vent
E. Range hood
F. Cabinet
G. Wall
H. 12” (30.5 cm) min.
I. 17” (43.2 cm) min. vent
cover height
*NOTE: 12” (30.5 cm) high cabinets without soffit may allow
the 6” (15.2 cm) vent and vent coverto be seen.
Electrical requirements
I WARNING
PLUG INTO A GROUNDED 3 PRONG OUTLET.
DO NOT REMOVE GROUND PRONG.
DO NOT USE AN ADAPTER.
DO NOT USE AN EXTENSION CORD.
FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT
IN DEATH, FIRE, OR ELECTRICAL SHOCK.
IMPORTANT: The range hood must be electrically grounded in
accordance with local codes and ordinances, or in the absence
of local codes, with the National Electrical Code, ANSI/NFPA
70 (latest edition) or Canadian Electrical Code, CSA C22.1
No. 0-M91 (latest edition).
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine
that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
A 120 volt, 60 Hz, AC only, 15- or 20-amp, fused electrical
circuit is required. A time-delay fuse or circuit breaker is
also recommended. It is recommended that a separate
circuit serving only this range hood be provided.
This range hood is equipped with a power supply cord
having a 3 prong grounding plug.
To minimize possible shock hazard, the cord must be plugged
into a mating, 3 prong, grounding-type outlet, grounded
in accordance with local codes and ordinances. If a mating
outlet is not available, it is the personal responsibility and
obligation of the customer to have the properly grounded
outlet installed by a qualified electrician.
7
The grounded 3 prong outlet is to be located inside the
cabinet above the range hood at a maximum distance
of 33
7
16” (85.0 cm) from where the power cord exits the
hood. The grounded 3 prong outlet must be accessible
after installation of the range hood. See illustration:
33 " (85 cm)
GROUNDING INSTRUCTIONS
This range hood must be grounded. In the event of an electri-
cal short circuit, grounding reduces the risk of electric shock
by providing an escape wire for the electric current.
This range hood is equipped with a cord having a grounding
wire with a grounding plug. The plug must be plugged into an
outlet that is properly installed and grounded.
WARNING: Improper grounding can result in a risk of electric
shock.
Consult a qualified electrician if the grounding instructions are
not completely understood, or if doubt exists as to whether
the range hood is properly grounded.
Do not use an extension cord. If the power supply cord is too short,
have a qualified electrician install an outlet near the range hood.
SAVE THESE INSTRUCTIONS
Installation instructions
Prepare location
It is recommended that the vent system be installed befo-
re the range hood is installed.
Before making cutouts, make sure there is proper clearan-
ce within the ceiling or wall for vent fittings.
Making the cutout to the bottom of the cabinet may be
easier to do prior to mounting the cabinet to the wall.
1 Disconnect power.
2 Determine which venting method to use: roof, wall, or non
vented.
3 Select a flat surface for assembling the range hood. Place
covering over that surface.
I WARNING
EXCESSIVE WEIGHT HAZARD
USE TWO OR MORE PEOPLE TO MOVE AND INSTALL
RANGE HOOD.
FAILURE TO DO SO CAN RESULT IN BACK OR OTHER INJURY.
4 Using 2 or more people, lift range hood onto covered
surface.
Range hood cabinet cutout
1 Use a saber saw or keyhole saw to cut out the cabinet
bottom inside the cabinet frame.
*NOTE: Frameless type cabinets require ¾” (1.9 cm) front lip in
the cabinet bottom. A ¾” (1.9 cm) thick filler strip (not su-
pplied) may be required for some types of cabinets. (See
Step 3 in the “Install Range Hood” section).
Cut out dimensions (without spacers)
A.
A
B
C
D
E
A. Bottom of cabinet cutout
B. Bottom must be cut flush to the inside walls of the cabinet.
C. 107/8” (27.6 cm) min. from the inside of the cabinet front face.
D. 3/4” (19 mm) thick front face required for cabinet bottom.
E. Front of cabinet
2 Complete cabinet preparation following the instruction
for your type of venting. Determine venting cutout locations
and cut out vent openings in the cabinets, walls and or
sot.
Venting outside through the roof
1 Measure and mark the lines as shown. Use a saber saw or
keyhole saw to cut an opening through the top of the cabi-
net and the roof for the vent.
D
A
B*
C
A. Cutout
B. 6
1
4” (15.9 cm)*
C. 7
3
4” (19.7 cm) centerline to
cabinet front
D. Centerline of the cabinet
*NOTE: For 12” (30.5 cm) high cabinets, a 61/4” deep x 8”
wide (14.6 cm x 20.3 cm) rectangular opening in the cabinet
top is required for damper transition clearance.
Venting outside through the wall
1 Install the 6” (15.2 cm) vent transition to the top of the
range hood liner using two 3.5 x 9.5 mm screws. Assemble
the vent duct that you will use over the 6” (15.2 cm) vent
transition. Measure from the bottom of the range hood
liner to the horizontal centerline of the vent opening (A).
A
B
C
A. Measurement A
B. Horizontal centerline of vent
opening
C. Range hood liner
8
4 Remove the vent duct from the range hood liner. Transfer
measurement A to the cabinet back wall. Measure from the
underside of the cabinet.
5 Mark the cutout as shown. Use a saber saw or keyhole saw
to cut a round opening through the back of the cabinet and
the exterior wall for the vent.
B
A
C
A. Measurement A
B. Centerline
C. 6¼” (15.9 cm)
round cutout
Non-vented (recirculating) installation through the soffit/
cabinet
1 Measure and mark the centerline of the cabinet to the sot
above.
2 Measure from the bottom of the cabinet to the centerline
of the where the vent will come through the sot. Mark the
location and use a saber saw or keyhole saw to cut a 5¾”
(14.6 cm) hole for the vent cover.
A
B
A. Vent cover
B. Centerline
3 Measure and mark the centerline location for the cutout in
the cabinet top. Use a saber saw or keyhole saw to cut an
opening for the vent.
D
A
B*
C
A. Cutout
B. *See chart
below.
C. 73/4” (19.7
cm) centerline to
cabinet front
D. Centerline
Cabinet Height Hole Shape and Size
12” (30.5 cm)
A 61/4” deep x 8” wide (15.9 cm
x 20.3 cm) rectangular opening
in the cabinet top is required for
damper transition clearance.
15” (38.1 cm) cabinet or
soffit installation
A 61/4” (15.9 cm) diameter round
opening is required
18” (45.7 cm) or 24”
(61.0)
A 53/4” (14.6 cm) diameter round
opening is required.
For non-vented (recirculating) installations only, the range
hood can be vented indoors through the top of the cabinet.
See the “Available Accessories” section for Recirculation Kit.
Complete preparation
1 If not yet attached, install the 6” (15.2 cm) vent transition
the top of the range hood liner using two 3.5 x 9.5 mm screws.
2 Locate side mounting bracket flush 1 cm to the bottom
of the cabinet side and against the inside of the front
cabinet face. Drill
1
8” (3 mm) pilot holes in 6 places, attach
a bracket using three 4.5 x 13 mm screws to each side of
the cabinet, and tighten. Additional washers in hardware
package are supplied as spacers for cabinet walls thinner
than ½”(13 mm).
Bracket Orientation
A
B
C
D
A. 30” (76.2 cm) or 36” (91.4 cm)
cabinet
B. Screws - 4.5 x 13 mm (6)
C. Washers (optional)
D. Mounting bracket (2) (position
for 30” [76.2 cm] or 36” [91.4 cm]
cabinet)
3 Install the vent system according to the method needed.
Use caulking to seal the exterior wall or roof opening.
9
Install range hood
I WARNING
EXCESSIVE WEIGHT HAZARD.
USE TWO OR MORE PEOPLE TO MOVE AND INSTALL
RANGE HOOD.FAILURE TO DO SO CAN RESULT IN BACK OR
OTHER INJURY.
1 Using 2 or more people, lift the hood liner into its mounte
location. Attach with four 4.2 x 19 mm screws into the
slotted openings. Do not tighten screws.
A
B
C
D
A. Cabinet
B. Hood liner canopy assembly
C. Screws - 4.2 x 19 mm (8)
D. Spacer (optional)
2 If needed, insert spacers between each side of the canopy
and the mounting plate to space and center the canopy
inthe cabinet. Align the bottom of the canopy with the
bottom of the cabinet. Install four 4.2 x 19 mm screws into
the round mounting plate openings and tighten all eight
mounting screws.
3 (For some installations): A filler strip may be required
for some cabinets.Install a filler strip and secure with two
4.5 x 13 mm screws from inside the front of the hood liner
assembly.
B
A
A. Screws: 4.5 x 13 mm B. Filler strip
4 Remove the metal grease filters from the face panel.
5 Attach the face panel to the hood liner. (Three sizes:
The30”x 12” [76.2 cm x 30.5 cm] cabinet size is shown.)
See instruction below for your specific cabinet size.
A
B
C
D
A. Screws: 3.5 x 9.5 mm flat-head (4)
B. Face plate (30” x 12” [76.2 cm x 30.5 cm] shown)
C. Cabinet (30” x 12” [76.2 cm x 30.5 cm] shown
D. Screws: 4.2 x 15 mm truss-head (2)
For cabinet size: 30” x 12” (76.2 cm x 30.5 cm)
1 Attach the 30” x 12” (76.2 cm x 30.5 cm) face panel (su-
pplied with range hood) to the hood liner using four 3.5 x
9.5 mm flat-head screws and two 4.2 x 15 mm truss head
screws. Tighten to secure.
2 Connectthelamp electrical connector.
For cabinet size: 30” x 18” (76.2 cm x 45.7 cm)
1 Assemble the 30” x 6” (76.2 cm x 15.2 cm) face panel
rear extension (see the “Assistance or Service” section
to order) to the 30” x 12” (76.2 cm x 30.5 cm) face panel
(supplied with the range hood) using eight 4.2 x 8 mm
screws (supplied with the face panel rear extension).
2 Attach the 30” x 18” (76.2 cm x 45.7 cm) face panel
assembly to the hood liner using four 3.5 x 9.5 mm flat-
head screws and two 4.2 x 15 mm truss head screws.
Tighten to secure.
3 Connectthelamp electrical connector.
A
B
C
A
A. Screws: 4.2 x 8 mm (8)
B. Face panel
C. Face panel rear extension
10
Connect the vent system
Vented Installations
1 Connect the vent system to the range hood vent opening.
Seal the connection with clamps.
Non-Vented (recirculating) Installations
1 Connect the vent system to the range hood vent opening.
Seal the connection with clamps.
2 Install charcoal filters.
See the “Available accessories” section for Recirculation kit.
Complete installation
1 Replace grease filters. See the “Maintenance” section.
I WARNING
ELECTRICAL SHOCK HAZARD
I WARNING
PLUG INTO A GROUNDED 3 PRONG OUTLET.
DO NOT REMOVE GROUND PRONG.
DO NOT USE AN ADAPTER.
DO NOT USE AN EXTENSION CORD.
FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT
IN DEATH, FIRE, OR ELECTRICAL SHOCK.
2 Plug 3-prong power cord into a grounded 3-prong outlet
located inside the cabinet above the range hood.
3 Check the operation of the range hood fan and light. See
“Description of the hood” section. If range hood does not
operate, check to see whether a circuit breaker has tripped
or a household fuse has blown. Disconnect power and
check wiring connections.
NOTE: To get the most efficient use from your new range
hood, read the “Description of the hood” section.
4 Install the cabinet doors to the cabinet. Use the assembly
instructions that come with the cabinet.
Description of the hood
The range hood is designed to remove smoke, cooking vapors
and odors from the cooktop area. For best results, start the
hood before cooking and allow it to operate several minutes
after the cooking is complete to clear all smoke and odors
from the kitchen.
The hood controls are located on the center of the front of
the range hood liner.
A
B
C
D
A. Blower and light controls
B. Grease filter
C. Grease filter handle
D. LED lamps
Controls
1
2
3
4
1. Light On/O button
2. Blower On/O button and speed minimum button
3. Blower speed medium button
4. Blower speed maximum button
Operating the light
The Light On/Off button (1) controls both lights. Press once
for On and again for Off.
Operating the blower
The Blower Speed buttons turn the blower on and control the
blower speed and sound level for quiet operation. The speed
can be changed anytime during fan operation by pressing the
desired blower speed button.
Press the Blower Off button a second time to turn off the
blower.
Maintenance
Cleaning
Do not spray cleaners directly to the control while cleaning
the Hood. The cooker hood should be cleaned regularly (at
least with the same frequency with which you carry out main-
tenance of the fat filters) internally and externally. Do not use
abrasive products. Do not use chlorine base cleaners.
DO NOT USE ALCOHOL!
To avoid damage to the exterior surface, do not use steel wool
or soap-filled scouring pads.
Always wipe dry to avoid water marks.
Cleaning Method:
Liquid detergent soap and water, or all-purpose cleanser.
Wipe with damp soft cloth or nonabrasive sponge, then rinse
with clean water and wipe dry.
I WARNING
Failure to carry out the basic cleaning recommendations of
the cooker hood and replacement of the filters may cause fire
risks.
Therefore, we recommend oserving these instructions.
The manufacturer declines all responsibility for any damage to
the motor or any fire damage linked to inappropriate main-
tenance or failure to observe the above safety recommenda-
tions.
Metal grease filter
The filters should be washed frequently. Place metal filters in
dishwasher or hot detergent solution to clean. Let filter dry
throughly before replacing it.
Turn off fan and lights. Allow lamps to cool.
1 Remove each filter by pulling the spring release handle (A)
and then pulling down the filter.
A
11
2 Wash metal filters as needed in dishwasher or hot
detergent solution.
3 Reinstall the filter by making sure the spring release handles
are toward the front. Insert metal grease filter into upper
track.
4 Pull the spring release handle down.
5 Push up on metal filter and release handle to latch into place.
6 Repeat steps 1-5 for the other filter.
Replacing a LED lamp
Turn o the range hood and allow the LED lamp to cool. To
avoid damage or decreasing the life of the new bulb, do not
touch bulb with bare fingers. Replace bulb using tissue or
wearing cotton gloves to handle bulb.
If new lamps do not operate, make sure the lamps are inserted
correctly before calling service.
1 Disconnect power.
2 Push up on the lens and turn it counterclockwise.
3 Remove the bulb and replace it with a 120-volt, 6.5-watt
maximum LED bulb with a GU10 base. Turn it clockwise
to lock it into place.
4 Repeat steps 2-3 for the other bulb if needed.
5 Reconnect power.
Available accessories
Recirculation kit - KIT02770
(for non-vented installations only)
The charcoal filters cannot be cleaned. It should be
replaced every 4-6 months (depending on hood usage).
1 Cover the grill that protects the suction motor with the
carbon filter so that the slots on the filter correspond to
the pins on the sides of the motor protection grill.
A
B
C
A. Charcoal filter
B. Pins
C. Blower motor
2 Remove the cable ties in the carbon filter and turn the
carbon filter clockwise to block them (bayonet fixing).
Face Panel Rear Extension - KIT02773
(for 30” x 18” [76.2 cm x 45.7 cm] cabinet)
ELICA North America
TWO-YEAR LIMITED WARRANTY
TO OBTAIN SERVICE UNDER WARRANTY
Owner must present proof of original purchase date. Please keep a copy of your dated proof of purchase (sales slip) in
order to obtain service under warranty.
PARTS AND SERVICE WARRANTY
For the period of two (2) years from the date of the original purchase, Elica will provide free of charge, non consumable
parts or components that failed due to manufacturing defects. During these two (2) years limited warranty, Elica will also
provide free of charge, all labor and in-home service to replace any defective parts.
WHAT IS NOT COVERED
Damage or failure to the product caused by accident or act of God, such as, flood, fire or earthquake.
Damage or failure caused by modification of the product or use of non-genuine parts.
Damage or failure to the product caused during delivery, handling or installation.
Damage or failure to the product caused by operator abuse.
Damage or failure to the product caused by dwelling fuse replacement or resetting of circuit breakers.
Damage or failure caused by use of product in a commercial application.
Service trips to dwelling to provide use or installation guidance.
Light bulbs, metal or carbon filters and any other consumable part.
Normal wear of finish.
Wear tonish due to operator abuse, improper maintenance, use of corrosive or abrasive cleaning products/pads and
oven cleaner products.
WHO IS COVERED
This warranty is extended to the original purchaser for products purchased for ordinary residential use in North America
(Including the United States, Guam, Puerto Rico, US Virgin Islands & Canada).
This warranty is non-transferable and applies only to the original purchaser and does not extend to subsequent owners of
the product. This warranty is made expressly in lieu of all other warranties, expressed or implied, including, but not limited
to any implied warranty of merchantability or fitness for a particular purpose and all other obligations on the part of Elica
North America, provided, however, that if the disclaimer of implied warranties is ineective under applicable law, the dura
-
tion of any implied warranty arising by operation of law shall be limited to two (2) years from the date of original purchase
at retail or such longer period as may be required by applicable law.
Th
is warranty does not cover any special, incidental and/or consequential damages, nor loss of profits, suered by the
original purchaser, its customers and/or the users of the Products.
WHO TO CONTACT
To obtain service under warranty or for any service related question:
Elica North America Service, call at 1 888 732 8018
For Eastern Canada, call AGI Services at 1 888 651 2534 Ask for the service department
elica@servicepower.com
Register your product in
elica.com
and earn a 3
rd
year of factory
warranty, covering all parts
plus in-home labor.
13
FRANÇAIS
Table des matières
Avis de sécurité important .......................................................................................................................................................................................... 14
Liste des pièces ............................................................................................................................................................................................................... 15
Pièces fournies ........................................................................................................................................................................................................... 15
Pièces non fournies .................................................................................................................................................................................................. 15
Exigences d’emplacement .......................................................................................................................................................................................... 16
Exigences concernant l’évacuation ......................................................................................................................................................................... 16
Spécifications électriques ........................................................................................................................................................................................... 17
Instrucrions d’installation ........................................................................................................................................................................................... 18
Installation de la hotte ............................................................................................................................................................................................. 20
Raccordement du circuit d’evacuation ............................................................................................................................................................. 21
Achever l’installation ................................................................................................................................................................................................ 21
Description de la hotte ................................................................................................................................................................................................ 21
Commandes ..................................................................................................................................................................................................................... 21
Entretien ............................................................................................................................................................................................................................ 22
Garantie .............................................................................................................................................................................................................................. 23
APPROUVÉ POUR LES APPAREILS DE TYPE RÉSIDENTIEL
POUR UNE UTILISATION RÉSIDENTIELLE SEULEMENT
LISEZ CES INSTRUCTIONS ET CONSERVEZ-LES
VEUILLEZ LIRE CES INSTRUCTIONS AU COMPLET AVANT DE COMMENCER.
L’INSTALLATION DE L’APPAREIL DOIT RESPECTER TOUS LES CODES EN VIGUEUR.
IMPORTANT : Conservez ces instructions afin de pouvoir les remettre à l’inspecteur-électricien de votre région.
INSTALLATEUR : Veuillez laisser ces instructions avec l’appareil pour le propriétaire.
PROPRIÉTAIRE : Veuillez conserver ces instructions pour pouvoir vous y référer plus tard.
Avertissement de sécurité : Coupez l’alimentation du circuit dans le panneau électrique et verrouillez le
panneau avant de raccorder les fils de cet appareil.
Exigence : 120 V c.a., 60 Hz circuit de dérivation de 15 V c.a., 20 Hz, de 15 ou 20 A.
14
I
AVIS DE SÉCURITÉ IMPORTANT
A. N’utilisez aucun ventilateur dont le cordon ou la fiche est
endommagé. Jeter le ventilateur ou retourner à un centre de
service autorisé pour examen et / ou réparation.
B. Ne faites pas passer le cordon sous la moquette. Ne couvrez
pas le cordon avec des tapis, des glissières ou des revêtements
similaires. Ne faites pas passer le cordon sous des meubles ou
des appareils électroménagers. Éloignez le cordon de la zone
de circulation et où il ne risque pas de trébucher.
I ATTENTION
UTILISER CET APPAREIL À DES FINS DE VENTILATION
GÉNÉRALE SEULEMENT. NE PAS UTILISER CET APPAREIL
POUR ÉVACUER DES MATÉRIAUX OU DES VAPEURS
DANGEREUX OU EXPLOSIFS.
IAVERTISSEMENT
POUR RÉDUIRE LES RISQUES D’INCENDIE, DE CHOC
ÉLECTRIQUE ET DE BLESSURE, RESPECTER LES DIRECTIVES
SUIVANTES:
A. Utiliser cet appareil uniquement aux fins prévues par le
fabricant. Si vous avez des questions à propos de l’appa-
reil, communiquez avec le fabricant.
B. Avant de faire l’entretien de l’appareil ou de le nettoyer,
coupez l’alimentation dans le panneau électrique et verrouillez
le panneau en bloquant le dispositif permettant d’empêcher
d’activer l’alimentation accidentellement. S’il n’est pas
possible de verrouiller l’accès au panneau, fixez une étiquette
très voyante au panneau électrique.
C. Une personne qualifiée doit eectuer l’installation et le
câblage des fils électriques en conformité avec tous les
codes et toutes les normes, y compris la cote de résistance
au feu.
D. Il est important de prévoir susamment d’air pour assu-
rer une bonne combustion de l’équipement de chaue et
l’évacuation adéquates des gaz par le conduit de cheminé
afin de prévenir les refoulements d’air. Respectez les directi-
ves et les normes de sécurité des fabricants de l’équipement
de chauage, comme celles publiées par la National Fire
Protection Association (NFPA), la American Society for
Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE) et le code des autorités de votre région.
E. Au moment de couper ou de percer un mur ou un plafond,
assurez-vous de ne pas endommager la filerie électrique
ou tout autre accès à un service publique.
F. Il faut toujours évacuer à l’extérieur les systèmes conduit.
I ATTENTION
Pour réduire les risques d’incendie et évacuer l’air correctement,
assurez-vous que le conduit mène à l’extérieur; il ne faut pas
évacuer l’air dans l’espace entre les murs, dans les plafonds, dans
les greniers, les vides sanitaires ou les garages.
IAVERTISSEMENT
POUR RÉDUIRE DES RISQUES D’INCENDIE, UTILISEZ
UNIQUEMENT DES CONDUITS EN MÉTAL.
I ATTENTION
Dispositif à fonctionnement automatique - pour réduire le
risque de Blessure Déconnecter de l’alimentation avant l’en-
tretien.
IAVERTISSEMENT
Pour réduire les risques d’incendie et de choc électrique,
n’utilisez pas cette hotte avec un contrôleur de vitesse à
semi-conducteurs.
Installez cette hotte en respectant toutes les exigences
mentionnées.
I ATTENTION
Dispositif à commande automatique - pour réduire le risque
de Blessure Débrancher de l’alimentation électrique avant la
maintenance.
IAVERTISSEMENT
POUR RÉDUIRE LES RISQUES D’INCENDIE DE GRAISSE SUR
LES CUISINIÈRES.
a) Ne laissez jamais la cuisinière sans surveillance lorsqu’elle
est réglée à une haute température. Les débordements par
bouillonnement causent de la fumée et des débordements
de gras qui peuvent s’enflammer. Faites chauer l’huile
lentement, à une température basse ou moyenne.
b) Faites toujours fonctionner la hotte lorsque vous utilisez
la cuisinière à une haute température ou que vous faites
flamber des aliments (P. ex. : crêpes Suzette, cerises
jubilées, boeuf au poivre flambé).
c) Nettoyez les hélices de ventilation fréquemment. Il ne faut
pas que la graisse s’accumule sur les filres ou les hélices.
d) Utilisez le bon format de casserole. Utilisez toujours un
chaudron de taille approprié à l’élément de la cuisinière.
IAVERTISSEMENT
POUR ÉVITER DE BLESSER QUELQU’UN LORS D’UN
INCENDIE DE GRAISSE SUR LA CUISINIÈRE, SUIVRE LES
CONSEILS SUIVANTS:
a
a) ÉTOUFFER LES FLAMMES avec un couvercle aux
dimensions de la taque de cuisson, une tôle à biscuit ou
tout autre plateau métallique, puis couper le gaz ou
l’alimentation électrique de la cuisinière. FAIRE
ATTENTION A NE PAS SE BRÛLER. Si les flammes ne
s’éteignent pas immédiatement, QUITTER LA PIÈCE ET
APPELER LES POMPIERS.
b) NE JAMAIS PRENDRE EN MAIN UNE CASSEROLE EN
FEU, vous pourriez vous blesser.
c) NE PAS UTILISER D’EAU, y compris les essuies de vaisselle
ou les serviettes humides – une violente explosion due à la
vapeur formée pourrait survenir.
d) Utiliser un extincteur SEULEMENT si:
1) Vous êtes sûr d’avoir un extincteur de classe ABC que
vous savez utiliser.
2) Le feu est petit et confiné à la zone où il s’est formé.
3) Les pompiers ont été appelés.
4) Vous pouvez lutter contre le feu avec une sortie
derrière vous.
a Recommandations tirées des conseils de sécurité en cas d’incendie de cuisine
publiés par la NFPA.
.
MODE OPÉRATOIRE
Toujours laisser les grilles de sécurité et les filtres à leurv
place. Sans la présence de ces derniers, les parties aspirantes
pourraient attirer les cheveux, les doigts ou les vêtements.
Le fabricant décline toute responsabilité si les informations
détaillées dans ce manuel pour l’installation, l’entretien et
l’utilisation adéquate du produit ne sont pas observées. Le
fabriquant décline en outre toute responsabilité pour
d’éventuelles blessures dues à des négligences; en outre, la
garantie de l’appareil sera annulée suite à des conditions
d’entretien inappropriées. Cet appareil est fabriqué pour un
usage interne. Ne pas utiliser cet appareil à l’extérieur.
15
LISTE DES PIÈCES
Retirer les pièces de leur emballage.
I ATTENTION
Enlever délicatement le carton, porter des gants pour se protéger des bords coupants.
I AVERTISSEMENT
Enlever le film de protection recouvrant le produit avant de commencer l’opération.
Pièces Fournies Quantité Pièces Fournies Quantité
Assemblage hotte avec souerie
et lampes DEL
1
Damper
1
Filtres à graisse métallique
2
Panneau de surface de 30” x 12”
(76,2 x 30,5 cm)
1
Brides de montage
2
4.5x13 mm
10
Cales d’espacement
6
4.2x15 mm
2
Adaptateur T10 TORX®†
1
3.5x9.5 mm
4
rondelles en plastique
8
4.2x19 mm
8
rondelles métalliques
8
3.5x9.5 mm
2
Pièces non Fournies
Outils nécessaires
Niveau
Perceuse
Foret de
1
8” (3 mm)
Crayon
Pince
Mètre-ruban ou règle
Pistolet à calfeutrage et composé de calfeutrage résistant
aux intempéries
Tournevis Phillips
Tournevis à lame plate
Scie sauteuse ou scie à guichet
Brides de conduit
Cisaille de ferblantier
Pièces nécessaires
Système de conduit d’évacuation métallique rond de 6”
(15,2 cm)
Pour les installations ventilées, vous aurez besoin
1 capuchon mural ou de toit
Pour les installations non ventilées (à recirculation), vous
aurez également besoin de:
Kit de recirculation. Voir la section “Accessoires”.
Exigences d’emplacement:
IMPORTANT: Observer les dispositions de tous les codes et
règlements en vigueur.
Confier l’installation de la hotte à un technicien qualifié.
C’est à l’installateur qu’incombe la responsabilité de respecter les
distances de séparation exigées, spécifiées sur la plaque signalétique
de l’appareil. La plaque signalétique de l’appareil est située derrière
le filtre, sur la paroi arrière gauche de la hotte.
Installer la hotte de cuisinière à distance de toute zone exposée à
des courants d’air, comme fenêtres, portes et bouches de chauage.
Respecter les dimensions indiquées pour les ouvertures à découper
dans les placards. Ces dimensions tiennent compte des valeurs
minimales des dégagements de séparation.
Avant d’eectuer des découpages, consulter les instructions
d’installation de la table de cuisson/cuisinière. On doit disposer
d’une prise de courant électrique reliée à la terre. Voir la section
“Spécifications électriques”.
La hotte a été configurée à l’usine pour une installation avec e sans
décharge à l’extérieur (recyclage), voir “Installation sans décharge
à l’extérieur (recyclage) à travers le sote/placard”, à la section
“Préparation de l’emplacement”.
Ensemble de filtres à charbon est disponible chez votre marchand
ou chez un distributeur de pièces autorisé. Assurer l’étanchéité au
niveau de chaque ouverture découpée dans le plafond ou le mur
pour l’installation de la hotte de cuisinière.
Installation dans une résidence mobile
L’installation de cette hotte doit satisfaire aux exigences de la norme
Manufactured Home Construction Safety Standards, Titre 24 CFR,
partie 328 (anciennement Federal Standard for Mobile Home Cons-
truction and Safety, titre 24, HUD, partie 280); lorsque cette norme
n’est pas applicable, l’installation doit satisfaire aux critères de la
plus récente édition de la norme Manufactured Home Installation
1982 (Manufactured Home Sites, Communities and Setups) ANSI
A225.1/NFPA 501A, ou des codes locaux.
®TORX est une marque déposée de Saturn Fasteners, Inc.
16
EXIGENCES D’EMPLACEMENT
Dimensions du produit
A
I
H
F
G
E
D
C
B
Modèle
EAS430SS
A 3/8” (10 mm)
B 30” (76.2 cm) or 36” (91.4 cm)
C 26” (66.1 cm)
D 2” (5.1 cm) or 5”(12.7 cm)
E 10
3
4” (27.4 cm)
F 3/4” (19 mm)
G 11
7
8” (30.2 cm) or 17
7
8” (45.4 cm)
H 9
1
8” (23.1 cm)
I 13
5
8” (33.7 cm)
Pour l’installation a partir de la surface de cuisson electrique
et au gaz: Monter cette hotte de sorte que le bord inférieur
est au minimum de 30“ (76,2 cm) au-dessus de la surface de
cuisson.
Dégagements de séparation
F
A
B
C
D
E
A. Hauteur minimale de placard
12” (30,5 cm)
B. B. Largeur de l’ouverture de
placard 30” (76,2 cm) min.
C. C. 30” (76,2 cm) min. à partir
de la surface de cuisson élec-
trique ou à gaz.
D. Profondeur de placard de
12” (30,5 cm)
E. Dégagement min. entre le haut
du placard et le plan de travail
de 15” (38,1 cm)
F. Hauteur de placard sur plancher
de 36” (91,4 cm)
*REMARQUE: Des placards de 30” (76,2 cm) de largeur
peuvent posséder une profondeur de 12” (30,5 cm) ou
18” (45,7 cm).
Des placards de 36” (91,4 cm) de largeur nécessitent une
profondeur de 18” (45,7 cm).
Pour des placards de 18” (45,7 cm) de profondeur, il faudra
acheter séparément une “Plaque d’extension arrière pour
panneau avant” (de 30” [76,2 cm]). Voir la sec-
tion “Assistance ou service” pour commander.
Exigences Concernant l’évacuation
Le circuit d’évacuation doit décharger l’air à l’extérieur,
excepté pour les installations sans décharge à l’extérieur
(recyclage).
Ne pas terminer le circuit d’évacuation dans un grenier ou
dans un autre espace clos.
Ne pas utiliser une bouche de décharge murale de 4” (10,2
cm) normalement utilisée pour un équipement de buan-
derie.
Utiliser un conduit métallique uniquement. Un conduit en
métal rigide est recommandé. Ne pas utiliser de conduit
de plastique ou en aluminium. La longueur du conduit de
décharge et le nombre de coudes doivent être réduits au
minimum pour fournir la meilleure performance.
Pour un fonctionnement ecace et silencieux:
Ne pas utiliser plus de trois coudes à 90°.
Veiller à ce qu’il y ait une section droite de conduit d’unmi-
nimum de 24” (61 cm) entre les raccords coudés, si on doit
en utiliser plus d’un.
Ne pas installer 2 coudes successifs.
Le circuit d’évacuation doit comporter un clapet anti-r flux.
Au niveau de chaque jointure du circuit d’évacuation, assu-
rer l’étanchéité avec les brides de serrage.
À l’aide d’un produit de calfeutrage, assurer l’étanchéité
autour de la bouche de décharge à l’extérieur (à travers le
mur ou le toit).
La taille du conduit doit être uniforme.
17
Installations dans les régions au climat froid
On doit installer un clapet anti-retour valve supplémentaire
à l’arrière pour minimiser le reflux d’air froid et incorporer un
élément d’isolation thermique pour minimiser la conduction
de chaleur par l’intermédiaire du conduit d’évacuation, de
l’intérieur de la maison à l’extérieur. Le clapet anti-retour valve
doit être placé du côté air froid de la résistance thermique.
L’élément d’isolation thermique doit être aussi proche que
possible de l’endroit où le circuit d’évacuation s’introduit dans
la partie chauffée de la maison.
Air d’appoint
Les codes du bâtiment locaux peuvent exiger l’emploi d’un
système de renouvellement de l’air/introduction d’air
d’appoint, lors de l’utilisation d’un système d’aspiration de dé-
bit supérieur à une valeur (pieds cubes par minute) spécifiée.
Le débit spécifié en pieds cubes par minute varie d’une juri-
diction à l’autre. Consulter un professionnel des installations
de chauffage ventilation/climatisation au sujet des exigences
spécifiques applicables dans la juridiction locale.
Méthodes d’évacuation
Cette hotte a été configurée à l’usine pour la décharge à tra-
vers le toit ou à travers le mur.
Le système de décharge requis pour l’installation n’est pas
fourni. Un circuit d’évacuation avec conduit circulaire de
6” (15,2 cm) est recommandé.
Décharge à travers le toit Évacuation par le mur
A
B
A. Conduit de dia. 6” (15,2 cm)
pour décharge à travers
le toit
B. Bouche de décharge sur
toit
A
B
A. Conduit de dia. 6” (15,2 cm)
pour décharge à travers
le mur
B. Bouche de décharge
murale
Calcul de la longueur effective du circuit d’évacuation
Pour la réalisation du circuit d’évacuation, on recommande un conduit de
6” (15,2 cm) de diamètre avec une longueur maximale de 35 pi (10,7 m).
Pour une performance optimale, ne pas utiliser plus de trois coudes à 90°.
Pour calculer la longueur eective du circuit d’évacuation nécessaire, ad-
ditionner les longueurs équivalentes (en pieds/ mètres) de tous les com-
posants utilisés dans le circuit.
Composant 6” (15,2 cm)
Coude à 45° 2,5 pi (0,8 m)
Coude à 90° 5,0 pi (1,5 m)
Installation sans décharge à l’extérieur (recyclage)
à travers le soffite/placard
S’il n’est pas possible d’évacuer les fumées et vapeurs de
cuisson à l’extérieur, on peut employer la version sans
décharge à l’extérieur (recyclage) de la hotte, dotée d’un filtre
à charbon. Ensamble de ltres à charbon, Voir la section “As-
sistance ou service” pour commander.
Through Cabinet Through Soffit
A
B
D
E
F
G
I
H
A
B
C
D
E
F
G
A. Ceiling
B. Vent cover
C. Sot
D. 6” (15.2 cm) vent
E. Range hood
F. Cabinet
G. Wall
H. 12” (30.5 cm) min.
I. 17” (43.2 cm) min. vent
cover height
REMARQUE : Pour des placards de 12” (30,5 cm) de hauteur
qui ne comportent pas de sote, le conduit et le cache-con-
duit de 6” (15,2 cm) peuvent rester visibles.
Spécifications électriques
I AVERTISSEMENT
BRANCHER SUR UNE PRISE À 3 ALVÉOLES RELIÉE À LA TERRE.
NE PAS ENLEVER LA BROCHE DE LIAISON À LA TERRE.
NE PAS UTILISER UN ADAPTATEUR.
NE PAS UTILISER UN CÂBLE DE RALLONGE.
LE NON-RESPECT DE CES INSTRUCTIONS PEUT CAUSER UN
DÉCÈS, UN INCENDIE OU UN CHOC ÉLECTRIQUE.
IMPORTANT: La hotte doit être correctement reliée à la terre
en conformité avec les codes et règlements locaux en vigueur,
ou en l’absence de tels codes, avec le National Electrical Code,
ANSI/ NFPA 70 (dernière édition) ou le Code canadien des
installations électriques, CSA C22.1. No. 0-M91 (dernière édition).
Si les codes le permettent et si on utilise un conducteur dis-
tinct de liaison à la terre, il est recommandé qu’un électricien
qualifié vérifie la qualité de la liaison à la terre. Pour obtenir un
exemplaire des normes des codes ci-dessus, contacter:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
Une alimentation de 120 volts, 60 Hz, CA seulement, de
15 ou 20 ampères, protégée par un fusible est requise. On
recommande également d’utiliser un fusible ou un disjonc-
teur temporisé. Il est recommandé de raccorder la hotte
sur un circuit distinct exclusif à cet appareil.
Cette hotte est équipée d’un cordon d’alimentation électrique
de liaison à la terre à trois broches.
18
Pour minimiser les risques de choc électrique, on doit
brancher le cordon sur une prise de courant de configuration
correspondante, à 3 alvéoles, reliée à la terre et installée
conformément aux codes et règlements locaux. Si une
prise de courant de configuration correspondante n’est
pas disponible, le client a la responsabilité et l’obligation
de faire installer par un électricien qualifié une prise de
courant correctement reliée à la terre.
La prise à 3 broches reliée à la terre doit se trouver dans
un placard situé au-dessus de la hotte, à une distance
maximale de 33
7
⁄16” (85,0 cm) à partir du point duquel le
cordon d’alimentation sort de la hotte. La prise à 3 broches
reliée à la terre doit être accessible une fois la hotte
installée. Voir l’illustration:
33 " (85 cm)
INSTRUCTIONS DE MISE À LA TERRE
Pour une hotte reliée à la terre et connectée par un cordon:
Cette hotte doit être reliée à la terre. Au cas où un courtcircuit se
produirait, la liaison à la terre réduit le risque de choc électrique,
en permettant au courant de s’échapper directement vers la terre.
La hotte est équipée d’un cordon comportant un conducteur de
liaison à la terre avec fiche de liaison à la terre. La fiche doit être
branchée dans une prise correctement installée et reliée à la terre.
AVERTISSEMENT: Une mise à la terre incorrecte peut entraîner un
risque de choc électrique.
Consulter un électricien qualifié si les instructions de mise à la terre ne
sont pas complètement comprises, ou si vous avez des doutes quant
à la qualité de la liaison à la terre de la hotte. Ne pas utiliser de câble
de rallonge. Si le cordon d’alimentation électrique est trop court, faire
installer une prise près de la hotte par un électricien qualifié.
CONSERVEZ CES INSTRUCTIONS
Instructions d’installation
Préparation de l’emplacement
Il est recommandé que l’installation du circuit d’évacuation-
soit réalisée avant celle de la hotte.
Avant de procéder aux découpages, vérifier que les dis-
tances de séparation pour les raccords dans les cavités du
plafond ou du mur sont adéquates.
Avant de monter le placard au mur, il sera peut-être plus
facile de découper au préalable l’ouverture dans le fond du
placard.
1 Déconnecter la source de courant électrique.
2 Déterminer la méthode d’évacuation à utiliser: décharge à
travers le mur ou le toit, ou recyclage.
3 Choisir une surface plane pour l’assemblage de la hotte.
Placer le matériau de protection sur cette surface.
I AVERTISSEMENT
RISQUE DU POIDS EXCESSIF
UTILISER DEUX OU PLUS DE PERSONNES POUR DÉPLACER
ET INSTALLER LA HOTTE DE LA CUISINIÈRE.
LE NON-RESPECT DE CETTE INSTRUCTION PEUT CAUSER
UNE BLESSURE AU DOS OU D’AUTRE BLESSURE.
4 À l’aide de deux personnes ou plus, soulever la hotte et la
poser sur la surface couverte.
Ouverture découpée du placard pour la hotte
1 Utiliser une scie sauteuse ou scie à guichet pour découper
une ouverture dans le fond du placard, à l’intérieur du
cadre du placard.
REMARQUE: Pour les placards sans cadres, un rebord
avant et arrière de 3/4” (19 mm) est nécessaire pour former
un cadre dans le fond du placard. Une tringle d’appui de
3/4” (19 mm) d’épaisseur (non fournie) sera peut-être
nécessaire pour certains types de placards. (Voir l’étape 3
de la section “Installation de la hotte”.)
Ouverture dimensions (sans barres d’espacement)
A
B
C
D
E
A. Ouverture dans le fond du placard.
B. Le découpage du fond du placard doit être en aeurement avec les
parois internes du placard.
C. 107/8” (27,6 cm) min. depuis l’intérieur de la partie avant du placard
D. Épaisseur de 3/4” (19 mm) obligatoire pour le fond du placard.
E. Avant du placard
2 Terminer la préparation du placard conformément aux
instructions correspondant au type d’évacuation du domi-
cile. Déterminer l’emplacement des ouvertures d’aération
et découper les ouvertures dans les placards, les murs et/
ou les sotes.
Décharge à l’extérieur, à travers le toit
1 Relever les mesures appropriées et tracer les lignes
indiquées sur l’illustration. Utiliser une scie sauteuse ou
une scie à guichet pour découper une ouverture à travers
le sommet du placard et le toit pour l’évacuation.
D
A
B*
C
A. Ouverture
B. 61/4” (15,9 cm)*
C. 73/4” (19,7 cm) entre l’axe cen-
tral et l’avant du placard
D. Axe central
REMARQUE : Pour les placards d’une hauteur de 12” (30,5
cm), une ouverture rectangulaire de 61/4” de profondeur x 8”
de largeur (14,6 cm x 20,3 cm) dans le sommet du placard est
obligatoire pour établir le dégagement nécessaire au raccord
de transition du clapet anti-reflux.
19
Décharge à l’extérieur, à travers le mur
1 Fixer le raccord de transition du conduit de 6” (15,2 cm) au
sommet de la caisse de la hotte à l’aide de deux vis de 3,5
x 9,5 mm. Assembler le conduit d’évacuation qui sera util-
isé sur le raccord de transition du conduit de 6” (15,2 cm).
Mesurer la distance entre le bas de la caisse de la hotte et
l’axe central horizontal de l’ouverture d’évacuation (A).
A
B
C
A. Mesure A
B. Axe central horizontal de
l’ouverture d’évacuation
C. Caisse de la hotte
D. Hauteur minimum de 12” (30,5 cm)
2 Retirer le conduit d’évacuation de la caisse de la hotte.
Reporter la dimension A sur la paroi arrière du placard.
Prendre les mesures à partir de la face inférieure du placard.
3 Marquer le périmètre de l’ouverture à découper – voir
l’illustration. Utiliser une scie sauteuse ou une scie à guichet
pour découper une ouverture circulaire à travers l’arrière
du placard et le mur extérieur pour l’évacuation.
B
A
C
A. Mesure A
B. Axe central
C. Ouverture découpée
circulaire de 6¼”
(15,9 cm)
Installation sans décharge à l’extérieur (recyclage) à travers
le sote/placard
1 Relever les mesures appropriées et tracer l’axe central du
placard jusqu’au sote situé au-dessus.
2 Mesurer la distance entre le bas du placard et l’axe
central, au point où le conduit d’évacuation ressort du sote.
Indiquer l’emplacement et utiliser une scie sauteuse ou
scie à guichet pour découper un trou de 5¾” (14,6 cm) pour
le cache-conduit.
A
B
A. Cache- conduit
B. Axe central
3 Relever les mesures appropriées et tracer l’axe central de
l’ouverture, dans le sommet du placard. Utiliser une scie
sauteuse ou scie à guichet pour découper une ouverture
pour le passage du conduit d’évacuation.
D
A
B*
C
A. Ouverture
B. *Voir le ta-
bleau ci-dessous.
C. 73/4” (19,7 cm)
entre l’axe central
et l’avant du
placard
D. Axe central
Hauteur du placard Taille et forme du trou
12” (30.5 cm)
Une ouverture rectangulaire de
61/4” de profondeur x 8” de largeur
(15,9cm x 20,3cm) dans le sommet
du placard est obligatoire pour
établir le dégagement nécessaire au
clapet anti-reflux.
15” (38,1 cm) :
Installation dans
placard ou soffite
Une ouverture circulaire de 61/4”
(15,9 cm) de diamètre est nácessaire.
18” (45.7 cm)
ou 24” (61.0)
Une ouverture circulaire de 53/4”
(14,6cm) de diamètre est nácessaire.
Pour les installations sans décharge à l’extérieur (recyclage)
uniquement, la hotte a été configurée peut être installée avec
décharge à l’intérieur du domicile, à travers le sommet du
placard.
Pour une installation sans décharge à l’extérieur (recyclage),
l’installation de filtres à charbon est nácessaire. Voir la section
“Entretien de la hotte” pour des instructions sur l’installation
de filtres au charbon.
Ensemble de recyclage. Voir la section “Assistance ou service”
pour commander.
Achever la préparation
1 S’il n’est pas encore fixé, installer le raccord de transition
de 6” (15,2 cm) au sommet de la caisse de la hotte à l’aide
de deux vis T10 de 3,5 x 9,5 mm.
2 Repérer l’emplacement de la bride latérale de montage,
en aeurement avec le bas de la paroi latérale du placard
et contre l’intérieur de la face avant du placard. Orienter
la bride tel qu’indiqué dans l’illustration suivante. Percer
des avan trous de
1
8” (3 mm) en 6 points diérents et fixer
une bride à l’aide de quatre vis Phillips n°2 de 4,5 x 13 mm
de chaque côté du placard - serrer ensuite. Le sachet de
matériel comporte des rondelles supplémentaires en plas-
tique qui peuvent être utilisées comme cales si lépaisseur
des parois du placard est inférieure à ½” (13 mm).
20
Orientation de la bride pour un placard
A
B
C
D
A. Placard de 30” (76,2 cm) ou 36”
(91,4 cm)
B. Vis de 4,5 x 13 mm (6)
C. Rondelles (facultatif)
D. Bride de montage (2) (position
pour un placard de 30” [76,2 cm]
ou 36” [91,4 cm])
3 Installer le circuit d’évacuation selon la méthode requise.
Utiliser un calfeutrant pour assurer l’étanchéité au point de
traversée du mur extérieur ou du toit.
Installation de la hotte
I AVERTISSEMENT
RISQUE DU POIDS EXCESSIF
UTILISER DEUX OU PLUS DE PERSONNES POUR DÉPLACER
ET INSTALLER LA HOTTE DE LA CUISINIÈRE.
LE NON-RESPECT DE CETTE INSTRUCTION PEUT CAUSER
UNE BLESSURE AU DOS OU D’AUTRE BLESSURE.
1 À l’aide d’au moins deux personnes, soulever la caisse de
la hotte et l’installer. Fixer quatre vis de 4,2 x 19 mm dans
les encoches. Ne pas serrer les vis.
A
B
C
D
A. Cabinet
B. Hood liner canopy assembly
C. Screws - 4.2 x 19 mm (8)
D. Spacer (optional)
2 Au besoin, insérer des cales de chaque côté de l’auvent et
de la plaque de montage pour permettre le dégagement
nécessaire et centrer l’auvent dans le placard. Aligner la
base de l’auvent avec le bas du placard. Installer quatre vis
de 4,2 x 19 mm dans les trous de la plaque de montage et
serrer les huit vis de montage.
3 (Pour certaines installations) : Une tringle d’appui peut
être nécessaire pour certains placards. Installer une tringle
d’appui et la fixer avec deux vis de 4,5 x 13 mm à partir de
l’intérieur de la caisse de hotte.
B
A
A. Vis : 4,5 x 13 mm B. Tringle d’appui
4 Ôter les filtres à graisse métalliques du panneau avant.
5 Fixer le panneau avant à la caisse de hotte. (Trois
tailles, la taille de placard illustrée correspond à une
dimension de 30” x 12” [76,2 cm x 30,5 cm]. Voir les
instructions données en fonction de la taille du placard
de l’utilisateur (ci-dessous).
A
B
C
D
A. Vis à tête plate de 3,5 x 9,5 mm (4)
B. Plaque avant (illustration 30” x 12” [76,2 cm x 30,5 cm])
C. Placard (illustration 30” x 12” [76,2 cm x 30,5 cm])
D. Vis à tête bombée de 4,2 x 15 mm (2)
Pour taille de placard : 30” x 12” (76,2 cm x 30,5 cm)
1 Fixer le panneau avant de 30” x 12” (76,2 cm x 30,5 cm)
(fourni avec la hotte) à la caisse de la hotte à l’aide de
quatre vis à tête plate de 3,5 x 9,5 mm et deux vis à tête
bombée de 4,2 x 15 mm. Serrer pour fixer l’ensemble.
2 Raccorder le connecteur des lampes.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

ELICA EAS430SS Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation
Ce manuel convient également à