Extron TLP Pro 300M Manuel utilisateur

Taper
Manuel utilisateur

Ce manuel convient également à

TLP Pro 320M
User Guide
TouchLink
®
TouchLink Pro Touchpanel Control Systems
68-2515-01 Rev. B
03 20
Safety Instructions • English
WARNING: This symbol, , when used on the product, is intended to
alert the user of the presence of uninsulated dangerous voltage within the
product’s enclosure that may present a risk of electric shock.
ATTENTION: This symbol, , when used on the product, is intended
to alert the user of important operating and maintenance (servicing)
instructions in the literature provided with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide, part number 68-290-01, on the Extron
website, www.extron.com.
Sicherheitsanweisungen • Deutsch
WARNUNG: Dieses Symbol auf dem Produkt soll den Benutzer darauf
aufmerksam machen, dass im Inneren des Gehäuses dieses Produktes
gefährliche Spannungen herrschen, die nicht isoliert sind und die einen
elektrischen Schlag verursachen können.
VORSICHT: Dieses Symbol auf dem Produkt soll dem Benutzer in
der im Lieferumfang enthaltenen Dokumentation besonders wichtige
Hinweise zur Bedienung und Wartung (Instandhaltung) geben.
Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung,
EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie
in den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer
68-290-01) auf der Extron-Website, www.extron.com.
Instrucciones de seguridad • Español
ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del
producto, lo que puede representar un riesgo de descarga eléctrica.
ATENCIÓN: Este símbolo, , cuando se utiliza en el producto, avisa
al usuario de la presencia de importantes instrucciones de uso y
mantenimiento recogidas en la documentación proporcionada con el
equipo.
Para obtener información sobre directrices de seguridad, cumplimiento
de normativas, compatibilidad electromagnética, accesibilidad y
temas relacionados, consulte la Guía de cumplimiento de normativas
y seguridad de Extron, referencia 68-290-01, en el sitio Web de Extron,
www.extron.com.
Instructions de sécurité • Français
AVERTISSEMENT : Ce pictogramme, , lorsqu’il est utilisé sur le
produit, signale à l’utilisateur la présence à l’intérieur du boîtier du
produit d’une tension électrique dangereuse susceptible de provoquer
un choc électrique.
ATTENTION : Ce pictogramme, , lorsqu’il est utilisé sur le produit,
signale à l’utilisateur des instructions d’utilisation ou de maintenance
importantes qui se trouvent dans la documentation fournie avec le
matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la
réglementation, la compatibilité EMI/EMF, l’accessibilité, et autres sujets
connexes, lisez les informations de sécurité et de conformité Extron, réf.
68-290-01, sur le site Extron, www.extron.com.
Istruzioni di sicurezza • Italiano
AVVERTENZA: Il simbolo, , se usato sul prodotto, serve ad
avvertire l’utente della presenza di tensione non isolata pericolosa
all’interno del contenitore del prodotto che può costituire un rischio di
scosse elettriche.
ATTENTZIONE: Il simbolo, , se usato sul prodotto, serve ad avvertire
l’utente della presenza di importanti istruzioni di funzionamento e
manutenzione nella documentazione fornita con l’apparecchio.
Per informazioni su parametri di sicurezza, conformità alle normative,
compatibilità EMI/EMF, accessibilità e argomenti simili, fare riferimento
alla Guida alla conformità normativa e di sicurezza di Extron, cod. articolo
68-290-01, sul sito web di Extron, www.extron.com.
Instrukcje bezpieczeństwa • Polska
OSTRZEŻENIE: Ten symbol, , gdy używany na produkt, ma na celu
poinformować użytkownika o obecności izolowanego i niebezpiecznego
napięcia wewnątrz obudowy produktu, który może stanowić zagrenie
porażenia prądem elektrycznym.
UWAGI: Ten symbol, , gdy używany na produkt, jest przeznaczony do
ostrzegania użytkownika ważne operacyjne oraz instrukcje konserwacji
(obsługi) w literaturze, wyposażone w sprzęt.
Informacji na temat wytycznych w sprawie bezpieczeństwa, regulacji wzajemnej
zgodności, zgodność EMI/EMF, dostępności i Tematy pokrewne, zobacz Extron
bezpieczeństwa i regulacyjnego zgodności przewodnik, część numer 68-290-01,
na stronie internetowej Extron, www.extron.com.
Инструкция по технике безопасности Русский
ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан
на продукте, предупреждает пользователя о наличии
неизолированного опасного напряжения внутри корпуса
продукта, которое может привести к поражению
электрическим током.
ВНИМАНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии важных инструкций
по эксплуатации и обслуживанию в руководстве,
прилагаемом к данному оборудованию.
Для получения информации о правилах техники безопасности,
соблюдении нормативных требований, электромагнитной
совместимости (ЭМП/ЭДС), возможности доступа и других вопросах
см. руководство по безопасности и соблюдению нормативных
требований Extron на сайте Extron: ,
www.extron.com, номер по каталогу - 68-290-01.
安全说明 简体中文
警告 产品上的这个标志意在警用户该产品机内有暴露的危电压,
电危险。
注意 产品上的这个标志意在提示用户设备随附的用户手册中有
重要的操作和维护(维修说明。
关于我们产品的安全指南、遵循的规范、EMI/EMF 的兼容性、无障碍
使用的特性等相关内容,敬请访问 Extron 网站 , www.extron.com,参见 Extron
安全规范指南,产品编号 68-290-01
Safety Instructions
안전 지침 • 한국어
경고: 이 기호 가 제품에 사용될 경우, 제품의 인클로저 내에 있는
접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이 있음을
경고합니다.
주의: 이 기호 가 제품에 사용될 경우, 장비와 함께 제공된 책자에 나와
있는 주요 운영 및 유지보수(정비) 지침을 경고합
니다.
안전 가이드라인, 규제 준수, EMI/EMF 호환성, 접근성, 그리고 관련 항목에
대한 자세한 내용은 Extron 웹 사이트(www.extron.com)의 Extron 안전 및
규제 준수 안내서, 68-290-01 조항을 참조하십시오.
安全記事 • 繁體中文
警告: 若產品上使用此符號是為了提醒使用者產品機殼內存在著
可能會導致觸電之風險的未絕緣危險電壓
注意 產品上使用此符號,是為提醒使用設備隨附的手冊中有
護( )説
有關安全性指導方針法規遵EMI/EMF 相存取圍和主題的詳細資
訊,請瀏覽 Extron 網站:www.extron.com然後參《Extron 安全性與法規
守手冊準則編號 68-290-01
安全上の注意
日本語
警告: この が製品上に表示されている場合は、筐体内に絶縁され
いない高電圧が流れ、感電の危険があるを示ていま
意:この が製品上に表示されている場合は機の取説明書に
載されている重な操作と保()のについてユーザーの
を喚起するものです
安全上の注意、法規厳守、EMI/EMF適合性、その他の関連項
スト イト www.extron.com Extron Safety
and Regulatory Compliance Guide』 ( P/N 68-290-01) ご覧ださい
Copyright
© 2015 - 2020 Extron Electronics. All rights reserved. www.extron.com
Trademarks
All trademarks mentioned in this guide are the properties of their respective owners.
The following registered trademarks (
®
), registered service marks (
SM
), and trademarks (
TM
) are the property of RGBSystems, Inc. or
ExtronElectronics (see the current list of trademarks on the Terms of Use page at www.extron.com):
Registered Trademarks
(
®
)
Cable Cubby, ControlScript, CrossPoint, DTP, eBUS, EDID Manager, EDID Minder, Extron, Flat Field, FlexOS, Glitch Free, Global Configurator,
Global Scripter, GlobalViewer, Hideaway, HyperLane, IPIntercom, IPLink, Key Minder, LinkLicense, LockIt, MediaLink, MediaPort, NetPA,
PlenumVault, PoleVault, PowerCage, PURE3, Quantum, ShareLink, Show Me, SoundField, SpeedMount, SpeedSwitch, StudioStation,
System I
NTEGRATOR, TeamWork, TouchLink, V-Lock, VideoLounge, VN-Matrix, VoiceLift, WallVault, WindoWall, XPA, XTP, XTP Systems, and
ZipClip
Registered Service Mark
(SM)
: S3 Service Support Solutions
Trademarks
(
)
AAP, AFL (Accu-Rate Frame Lock), ADSP (Advanced Digital Sync Processing), Auto-Image, AVEdge, CableCover, CDRS (Class D
Ripple Suppression), Codec Connect, DDSP (Digital Display Sync Processing), DMI (Dynamic Motion Interpolation), DriverConfigurator,
DSPConfigurator, DSVP (Digital Sync Validation Processing), eLink, EQIP, Everlast, FastBite, Flex55, FOX, FOXBOX, IP Intercom HelpDesk,
MAAP, MicroDigital, Opti-Torque, PendantConnect, ProDSP, QS-FPC (QuickSwitch Front Panel Controller), Room Agent, Scope-Trigger, SIS,
Simple Instruction Set, Skew-Free, SpeedNav, Triple-Action Switching, True4K, True8K, Vector™ 4K, WebShare, XTRA, and ZipCaddy
FCC Class A Notice
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part15 of the FCC rules. The ClassA limits provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause interference.
This interference must be corrected at the expense of the user.
NOTES:
This unit was tested with shielded I/O cables on the peripheral devices. Shielded cables
must be used to ensure compliance with FCC emissions limits.
For more information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and Regulatory
Compliance Guide on the Extron Website.
Battery Notice
This product contains a battery. Do not open the unit to replace the battery. If the
battery needs replacing, return the entire unit to Extron (for the correct address, see the Extron
Warranty section on the last page of this guide).
CAUTION: Risk of Explosion if Battery is replaced by an Incorrect Type. Dispose of Used
Batteries According to the Instructions.
ATTENTION : Risque d’explosion. Ne pas remplacer la pile par le mauvais type de pile.
Débarrassez-vous des piles utilisées selon le mode d’emploi.
Conventions Used in this Guide
Notifications
In this user guide, the following are used:
WARNING: Potential risk of severe injury or death.
AVERTISSEMENT : Risque potentiel de blessure grave ou de mort.
CAUTION: Risk of minor personal injury.
ATTENTION : Risque de blessuremineure.
ATTENTION:
Risk of property damage.
Risque de dommages matériels.
NOTE: A note draws attention to important information.
Software Commands
Commands are written in the fonts shown here:
^AR Merge Scene,,Op1 scene 1,1 ^B 51 ^W^C
[01] R 0004 00300 00400 00800 00600 [02] 35 [17] [03]
E
X!
*
X1&
*
X2)
*
X2#
*
X2!
CE
}
NOTE: For commands and examples of computer or device responses mentioned
in this guide, the character “0” is used for the number zero and “O” represents the
capital letter “o”.
Computer responses and directory paths that do not have variables are written in the font
shown here:
Reply from 208.132.180.48: bytes=32 times=2ms TTL=32
C:\Program Files\Extron
Variables are written in slanted form as shown here:
ping xxx.xxx.xxx.xxx —t
SOH R Data STX Command ETB ETX
Selectable items, such as menu names, menu options, buttons, tabs, and field names are
written in the font shown here:
From the File menu, select New.
Click the
OK button.
Specifications Availability
Product specifications are available on the Extron Website, www.extron.com.
Extron Glossary of Terms
A glossary of terms is available at www.extron.com/technology/glossary.aspx.
Contents
Introduction............................................................ 1
About the TLP Pro 320M .................................... 1
Features ............................................................. 1
Application Diagram ........................................... 2
Requirements ..................................................... 2
Software ......................................................... 2
Hardware ........................................................ 2
Installation Overview ........................................... 3
Panel Features ...................................................... 5
TLP Pro 320M Front Panel Features ................... 5
TLP Pro 320M Front Panel Features
(Bezel Removed) ............................................... 6
TLP Pro 320M Rear Panel Features .................... 7
Setup Menu .......................................................... 11
Status ............................................................... 12
Network ........................................................... 13
Display ............................................................. 15
Audio ................................................................ 16
Advanced ......................................................... 17
Calibration Screen ............................................ 18
Configuration Software ..................................... 19
Configuration Software ..................................... 19
Downloading Software...................................... 20
TLP Pro 320M Web Page ................................. 21
Updating Firmware ........................................... 22
Downloading Firmware ................................. 22
Updating Firmware Using the
Touchpanel Web Page ................................. 23
Updating Firmware Using Toolbelt ................. 23
Mounting ............................................................... 24
Wall or Furniture Mounting ................................ 24
Other Mounting Options ................................... 26
Underwriters Laboratories Guidelines for
Rack Mounting ............................................ 26
Button Kits ........................................................... 27
Installing or Replacing Buttons .......................... 27
Button Replacement ..................................... 27
Reference Material ............................................. 28
Network Port Requirements and
Licensed Third-Party Software ......................... 28
Reset Modes .................................................... 28
Use Factory Firmware ................................... 28
Reset All IP Settings ..................................... 29
Reset to Factory Defaults .............................. 29
Enable or Disable the DHCP Client ............... 30
Secure Sockets Layer (SSL) Certificates ........... 30
IEEE 802.1X Certificates ................................... 31
Certificate File Requirements......................... 31
Private Key File Requirements ....................... 31
TLP Pro 320M • Contents vii
TLP Pro 320M • Contents viii
Introduction
This guide describes the function, installation, and operation of the TLPPro320M
TouchLinkPro touchpanel. Unless otherwise stated, the terms “TLP Pro” and “touchpanel”
refer to the TLP Pro 320M.
This section contains the following information:
About the TLP Pro 320M
Features
Application Diagram
Requirements
About the TLP Pro 320M
The Extron TLP Pro 320M is a 3.5 inch wall mounted touchpanel with an 320x240 LCD
touchscreen. The front panel also has eight customizable backlit buttons and a volume control
knob. The TLP Pro 320M works with any Extron IP Link Pro control processor and is ideal
for any AV application requiring a compact touchpanel with flexible mounting options and
a fully customizable interface. A range of mounting options are available (see Mounting on
page 24).
Power over Ethernet (PoE) allows the touchpanel to receive power and communications over a
single Ethernet cable.
The screen layout is designed with the Extron GUI Designer software. The functions are
assigned to the screen objects with the Extron Global Configurator Plus and Professional
software. The user can define the graphics and the functions associated with those graphics,
providing versatility and adaptability to the configuration and control of an AV system.
A motion sensor, light sensor, and a speaker provide sleep mode, auto dimming, and audible
feedback.
Features
3.5-inch LCD touchscreen — with 320x240 resolution and 18-bit color depth.
Eight customizable backlit buttons and a user-friendly volume knob.
Compatible with all Extron IP Link Pro control processors.
Power over Ethernet (PoE 802.3af, class3) compliance — allows the touchpanel to
receive power and control over a single Ethernet cable, eliminating the need for a local power
supply. The power injector is sold separately.
Built-in speaker — provides audible feedback from button presses.
Light sensor — adjusts screen brightness as the ambient room lighting changes.
Configurable red and green status lights — indicate the availability or call status of a room.
System connection status indicator — the communication LED provides visual feedback if
the touchpanel is not communicating with a control processor.
Automatic clock synchronization — allows touchpanel to display the accurate time and
date.
Energy-saving features
Adjustable sleep timer puts touchpanel into sleep mode.
Motion detector wakes touchpanel.
Fully customizable using Extron control system software — using GUI Designer,
Global Configurator Plus and Professional, Global Scripter, and Toolbelt.
TLP Pro 320M • Introduction 1
Multiple mounting optionsmounts on a wall, lectern, or any flat surface.
Supports Extron Control App and Extron Control for Web.
JITC Certified — Successfully completed interoperability and information assurance
testing for use in government applications and other mission-critical environments.
Application Diagram
POWER
12V
--A MAX
G
Tx Rx RT S CTS
COM 1
G
Tx Rx
COM 2
VCG
VOL
RELAYS
1 2 C
1 2 3 4 G
DIGITAL I/O
PWR OUT = 6W
eBUS
+V +S
-S
G
LAN
IPCP PRO 250
IR/S
S G
POWER
12V
0.7A MAX
LR
L
8Ω / 4Ω
CLASS 2
WIRING
R
10V
VCG
50mA
L
MPA 152 Plus
R
INPUTS
OUTPUTS
REMOTE
1
MODEL 80
FLAT PANEL
PUSH PUSH
POWER GUIDE MENU RES 480 480p 720p 1080i 1080p
DIRECTV HD
SELECT
DIRECTV
PC
LAPTOP
DVD
DOC CAM
AUXILIARY
DISPLAY ON
DISPLAY OFF
MUTE
VideoMore
DVD
C
ombine
d
Combined
TCP/IP
Network
Ethernet/PoE
EthernetEthernet
IR
RS-232
Volume Control
Ethernet
Extron
IPCP Pro 250
IP Link Pro
Control Processor
Extron
TLP Pro 320M
3.5" Wall Mount
TouchLink Pro Touchpanel
Digital Input
Motion Sensor
Media PlayerSatellite Receiver
Flat Panel Display
Extron
MPA 152 Plus
Power Amplier
Audio
Audio
Video
Video
AudioAudio
Extron
SI 26CT
Two-Way Ceiling
Speakers
Figure 1. TLP Pro 320M Application Diagram
Requirements
Software
For a complete list of the requirements for running GUI Designer, Global Configurator Plus
and Professional, Global Scripter, or Toolbelt, see the Extron Web page for the appropriate
software.
NOTE: The TLP Pro 320M is not compatible with GlobalConfigurator 3 or
GUIConfigurator.
Hardware
An Extron IP Link Pro control interface must also be connected to the same network domain
as the TouchLink panel. See www.extron.com for a list of suitable controllers.
NOTE: These touchpanels are not compatible with Extron IP Link (non-Pro) controllers.
TLP Pro 320M • Introduction 2
Installation
Overview
1. Before starting, download and install the latest versions of the following software:
GUI Designer — for designing layouts for Extron TouchLink Pro touchpanels and
third party touch interfaces.
Global Configurator Plus and Professional — for setting up and configuring the
control processor and touchpanel.
Toolbelt — provides device discovery, device information, firmware updates,
and configuration of network settings, system utilities, and user management for
TouchLink Pro devices.
Global Scripter — provides device discovery, device information, firmware updates,
and configuration of network settings, system utilities, and user management for
TouchLinkPro devices.
See Configuration Software on page 19.
2. Obtain the following network information from your network administrator:
DHCP status (on or off). If DHCP is off, you will also require
IP address
Subnet mask
Gateway
User name — by default, these are either admin or user.
Passwords — The factory configured passwords for all accounts on this device
have been set to the device serial number. Passwords are case sensitive.
NOTE: If the device is reset to default settings, the password is the default
password configuration. The default password is extron (for either admin or
user accounts).
MAC address — make a note of the touchpanel MAC address.
3. Mount and connect cables to the units:
ATTENTION:
Do not power on the touchpanels or control processors until you have read the
Attention on page 8 (12 VDC power supply) or on page 10 (power injector).
Ne branchez pas les écrans tactiles ou les contrôleurs avant d’avoir lu les mises
en garde page 8 (source d’alimentation 12VCC) ou page 10 (injecteur PoE).
Mount the units. There are several mounting options for Touchlink Pro touchpanels
(see Mounting on page 24).
Connect cables to the touchpanels (see TLP Pro 320M Rear Panel Features on
page 7).
Connect the power cords and power on all devices (see Power connector on
page 7 or LAN and PoE Connector on page 9).
TLP Pro 320M • Installation Overview 3
4. Set up the Touchpanels for Network Communication:
Connect the PC that you will use for setup, the control processor, and the touchpanel
to the same Ethernet subnetwork.
Use the Setup Menu on page 11 or Toolbelt to set the DHCP status and, if
necessary, the IP address, subnet mask, gateway, and related settings for the
touchpanel.
5. Configure the Touchpanels — the Global Configurator Help File, the Toolbelt Help File,
and the GUI Designer Help File provide step-by-step instructions and detailed information.
The Global Configurator Help File includes an introduction to that software and sections
on how to start a project and configuration.
Global Scripter provides an Extron-exclusive Python library (ControlScript) and
Global Scripter modules to get you started. See the GlobalScripter Help File for more
information.
TLP Pro 320M • Installation Overview 4
Panel Features
This section describes:
TLP Pro 320M Front Panel Features
TLP Pro 320M Front Panel Features (Bezel Removed)
TLP Pro 320M Rear Panel Features
TLP Pro 320M Front Panel Features
A
A
A
B
B
B
D
D
D
B
B
B
E
E
E
C
C
C
FFF
F
FF
Figure 2. TLP Pro 320M Front Panel with Bezel
A
LCD screen — the 3.5 inch LCD touchscreen has a 320x240 resolution and 18-bit color
depth.
B
Status lights — one on each side can be programmed to provide system feedback.
Light red or green
Blink or light continuously
C
Bezel — can be removed to reveal other front panel features (see the following page).
D
Backlit buttons — eight buttons are back-lit by LEDs. The buttons provided with the
touchpanel are Laptop, PC, DVD, Doc Cam, Auxiliary, Display Off, Display On,
and Mute. You can replace any of the buttons to customize your touchpanel (see Button
Replacement on page 27).
The buttons must be configured with GlobalConfigurator Plus and Professional (see the
GlobalConfiguratorHelp File).
E
Volume control knob — for controlling volume but can be configured for other functions.
F
Notches — used to remove the bezel from the touchpanel. These cannot be seen from
the front of the touchpanel. They are on the bottom surface of the bezel, where it comes in
contact with the wall.
figure 2
TLP Pro 320M • Panel Features 5
TLP Pro 320M Front Panel Features (Bezel Removed)
To release the bezel from the TLP Pro 320M, use the Extron removal tool:
1. Insert the flat edge of the tool into either of the notches in the bottom surface of the bezel
(see figure 2,
F
, on page 5).
2. Gently, twist the tool so that the bezel separates from the touchpanel.
3. Move the tool along the edge of the bezel and repeat step 2 until the bezel is completely
detached from the touchpanel.
A
A
AB
B
BC
C
C
F
F
FD
D
D
D
D
D
E
E
E
Figure 3. TLP Pro 320M Front Panel without Bezel
A
Motion sensor — detects motion between 3 to 5 feet from the touchpanel and at least
15° from the center axis.
When no motion has been detected for a user-defined period of time, the screen
display enters into sleep mode.
When motion is detected by the sensor, the screen display is restored and active.
B
Communication LED — shows the configuration and connection status of the
touchpanel:
Unlit during normal operation (the touchpanel is configured and connected to an
IPLink Pro control processor).
Blinks red if the touchpanel has been configured but is not connected to an
IPLinkPro control processor.
Permanently lit if the touchpanel has not been configured.
Use the Setup Menu (see page 11) to toggle the indicator between enabled and
disabled.
C
Ambient light sensor — monitors ambient light level and adjusts screen brightness,
based on the settings configured using the Setup Menu.
D
Holes for mounting the touchpanel — allow the touchpanel to be attached to the
wall-plate adapter during Mounting (see page 24).
E
Speaker — one placed below the screen provides audible feedback from button presses.
F
Menu button — activates the Setup Menu.
Release the bezel
figure 3
TLP Pro 320M • Panel Features 6
TLP Pro 320M Rear Panel Features
A
A
A
B
B
B
C
C
C
D
D
D
A
Power connector (see page 7)
C
Reset LED (see page 9)
B
Reset button (see page 8)
D
LAN and PoE Connector (see page 9)
Figure 4. TLP Pro 320M Rear Panel Features
A
Power connector — Connect this 2-pole, 3.5 mm captive screw receptacle to a
12VDC, 1.0 A power supply (not provided). Go to www.extron.com to find a power
supply recommended by Extron.
Ensure the connections have the correct polarity as shown in figure 5.
WARNING: The two power cord wires must be kept separate while the power
supply is plugged in. Remove power before wiring.
AVERTISSEMENT : Les deux cordons d’alimentation doivent être tenus à l’écart
l’un de l’autre quand l’alimentation est branchée. Couper l’alimentation avant de faire
l’installation électrique.
ATTENTION:
Do not power on the touchpanels or control processors until you have read the
Attention on page 8 (12 VDC power supply) or on page 10 (power injector).
Ne branchez pas les écrans tactiles ou les contrôleurs avant d’avoir lu les mises
en garde page 8 (source d’alimentation 12VCC) ou page 10 (injecteur PoE).
NOTE: The TLP Pro 320M ships without a power supply. Either the 12 VDC power
supply or the power injector must be purchased separately.
Power Receptacle
Captive Screw Connector
SECTION A–A
Ridges
Smooth
Power Supply
Output Cord
AA
3/16"
(5 mm) Max.
+
POWER
12V
1.0A MAX
+
POWER
12V
1.0A MAX
External Power Supply
(12 VDC, 1.0 A max.)
Ground all
Devices
Ground
+12 VDC input
G
Figure 5. Power Supply Connection
figure 4
Power connector
TLP Pro 320M • Panel Features 7
ATTENTION:
Always use a power supply provided by or specified by Extron. Use of an
unauthorized power supply voids all regulatory compliance certification and may
cause damage to the supply and the end product.
Utilisez toujours une source d’alimentation fournie ou recommandée par Extron.
L’utilisation d’une source d’alimentation non autorisée annule toute conformité
réglementaire et peut endommager la source d’alimentation ainsi que le produit final.
This product is intended for use with a UL Listed power source marked “Class 2” or
“LPS” and rated 12VDC, minimum 1.0 A. or 48 VDC (PoE), minimum 0.35 A.
Ce produit est destiné à une utilisation avec une source d’alimentation listéeUL
avec l’appellation «Classe2» ou «LPS» et normée 12Vcc, 1,0A minimum ou
48Vcc(PoE), 0,35A minimum.
Extron power supplies are certified to UL/CSA 60950-1 and are classified as LPS
(Limited Power Source). Use of a non-LPS or unlisted power supply will void all
regulatory compliance certification.
Les sources d’alimentation Extron sont qualifiées UL/CSA60950-1 et sont
classéesLPS(LimitedPowerSource). L’utilisation d’une source d’alimentation non-
listée ou non-listéeLPS annulera toute certification de conformité réglementaire.
Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling
spaces or in wall cavities. The power supply is to be located within the same vicinity
as the Extron AV processing equipment in an ordinary location, Pollution Degree 2,
secured to the equipment rack within the dedicated closet, podium, or desk.
Sauf mention contraire, les adaptateurs AC/DC ne sont pas appropriés pour une
utilisation dans les espaces d’aération ou dans les cavités murales. La source
d’alimentation doit être située à proximité de l’équipement de traitement audiovisuel
dans un endroit ordinaire, avec un degré2 de pollution, fixé à un équipement de rack
à l’intérieur d’un placard, d’une estrade, ou d’un bureau.
The installation must always be in accordance with the applicable provisions of
National Electrical Code ANSI/NFPA 70, article 725 and the Canadian Electrical Code
part 1, section 16.
Cette installation doit toujours être en accord avec les mesures qui s’applique au
National Electrical Code ANSI/NFPA70, article725, et au Canadian Electrical Code,
partie1, section16.
The power supply shall not be permanently fixed to building structure or similar
structure.
La source d’alimentation ne devra pas être fixée de façon permanente à une structure
de bâtiment ou à une structure similaire.
The length of the exposed wires in the stripping process is critical. The ideal length is
3/16 inches (5 mm). Any longer and the exposed wires may touch, causing a short
circuit between them. Any shorter and the wires can be easily pulled out even if tightly
fastened by the captive screws.
La longueur des câbles exposés est primordiale lorsque l’on entreprend de les
dénuder. La longueur idéale est de 5mm (3/16inches). S’ils sont un peu plus longs,
les câbles exposés pourraient se toucher et provoquer un court circuit. S’ils sont un
peu plus courts, ils pourraient sortir, même s’ils sont attachés par les vis captives.
Do not tin the wire leads before installing into the connector. Tinned wires are not as
secure in the connector and could be pulled out.
Ne pas étamer les conducteurs avant de les insérer dans le connecteur. Les câbles
étamés ne sont pas aussi bien fixés dans le connecteur et pourraient être retirés.
B
Reset button (see figure 4 on page 7) — is in the recessed hole to the left of the
Reset LED. Pressing this button initiates one of three reset modes for the unit (see Reset
Modes on page 28).
Attention
mises en garde
Reset button
TLP Pro 320M • Panel Features 8
C
Reset LED (see figure 4 on page 7)— is in the center of the rear panel, to the right of the
reset button. It indicates power status and reset status of the device (see Reset Modes
on page 28).
D
LAN and PoE Connector — is on the right side of the recessed area.
Connect the touchpanel to the LAN using a twisted pair cable, terminated with an RJ-45
connector. Use a straight-through Ethernet cable to connect the panel to a switch or
router. Use a crossover cable to connect the panel directly to a computer.
An Extron IPL Pro Control Processor must also be connected to the same network
domain as the TouchLink Pro touchpanel. See the www.extron.com for a list of
suggested models.
The network port has two LEDs. The green LED lights steadily to indicate that the
touchpanel is connected correctly to a network. The yellow LED flashes to indicate that
data is being passed to or from the touchpanel.
The connector can also be used with a power injector (not provided). Extron recommends
using the XTP PI 100 power injector (part number 60-1233-01), which is shown in figure6
below.
ATTENTION:
The TLP Pro 320M can use a 12 VDC desktop power supply and is also Power
over Ethernet (PoE 802.3af, class3) compliant. Do not power on the touchpanels
or control processors until you have read the Attention on page 8 (12 VDC
power supply) or on page 10 (power injector).
Le TLP Pro 320M peut utiliser une source d’alimentation externe 12 Vcc, et
est également compatible avec l’alimentation POE via Ethernet (PoE802.3af,
classe3). Ne branchez pas les écrans tactiles ou les contrôleurs avant d’avoir
lu les mises en garde page 8 (source d’alimentation 12VCC) ou page 10
(injecteur PoE).
To use a power injector — connect a straight-through Ethernet cable to the power
supply and a switch or router. This cable carries network information from the switch or
router to the power supply input.
A second straight-through cable carries the network information and 48VDC from the
power supply to the touchpanel. Connect the IEC power cord to a convenient 100 VAC to
240 VAC, 50-60 Hz power source.
Figure 6 shows the Extron XTP PI 100. Your power injector may look different.
100-240V
~
50-60Hz
0.4A MAX
XTP
PWR
XTP PWR
To network switchTo TLP PRO 320M
Figure 6. Connecting the Power Injector
Reset LED
LAN and PoE Connector
TLP Pro 320M • Panel Features 9
ATTENTION:
The TLP Pro 320M is intended for connection to a Power over Ethernet circuit for
intra-building use only and are considered to be part of a Network Environment 0 per
IEC TR62101.
Le TLP Pro 320M est conçu pour une connexion à un circuit PoE pour une utilisation
intérieure seulement et est considéré comme faisant partie d’un environnement réseau
0 par IECTR62101.
Always use a power supply provided by or specified by Extron. Use of an
unauthorized power supply voids all regulatory compliance certification and may
cause damage to the supply and the end product.
Utilisez toujours une source d’alimentation fournie ou recommandée par Extron.
L’utilisation d’une source d’alimentation non autorisée annule toute conformité
réglementaire et peut endommager la source d’alimentation ainsi que le produit final.
This product is intended for use with a UL Listed power source marked “Class 2” or
“LPS” and rated 12VDC, minimum 1.0 A. or 48 VDC (PoE), minimum 0.35 A.
Ce produit est destiné à une utilisation avec une source d’alimentation listéeUL avec
l’appellation «Classe2» ou «LPS» et normée 12Vcc, 1,0A minimum ou 48Vcc
(PoE), 0,35A minimum.
Extron power supplies are certified to UL/CSA 60950-1 and are classified as LPS
(Limited Power Source). Use of a non-LPS or unlisted power supply will void all
regulatory compliance certification.
Les sources d’alimentation Extron sont qualifiées UL/CSA60950-1 et sont
classéesLPS(LimitedPowerSource). L’utilisation d’une source d’alimentation non-
listée ou non-listéeLPS annulera toute certification de conformité réglementaire.
Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling
spaces or in wall cavities. The power supply is to be located within the same vicinity
as the Extron AV processing equipment in an ordinary location, Pollution Degree 2,
secured to the equipment rack within the dedicated closet, podium, or desk.
Sauf mention contraire, les adaptateurs AC/DC ne sont pas appropriés pour une
utilisation dans les espaces d’aération ou dans les cavités murales. La source
d’alimentation doit être située à proximité de l’équipement de traitement audiovisuel
dans un endroit ordinaire, avec un degré2 de pollution, fixé à un équipement de rack
à l’intérieur d’un placard, d’une estrade, ou d’un bureau.
Power over Ethernet (PoE) is intended for indoor use only. It is to be connected only to
networks or circuits that are not routed to the outside plant or building.
L’alimentation via Ethernet (PoE) est destinée à une utilisation en intérieur uniquement.
Elle doit être connectée seulement à des réseaux ou des circuits qui ne sont pas
routés au réseau ou au bâtiment extérieur.
The installation must always be in accordance with the applicable provisions of
National Electrical Code ANSI/NFPA 70, article 725 and the Canadian Electrical Code
part 1, section 16.
Cette installation doit toujours être en accord avec les mesures qui s’applique au
National Electrical Code ANSI/NFPA70, article725, et au Canadian Electrical Code,
partie1, section16.
The power supply shall not be permanently fixed to building structure or similar
structure.
La source d’alimentation ne devra pas être fixée de façon permanente à une structure
de bâtiment ou à une structure similaire.
page 10
TLP Pro 320M • Panel Features 10
Setup Menu
When the TLP Pro 320M is powered on, the currently loaded project is displayed. To access
the setup menu, remove the front panel bezel and press the Menu button (see figure 3
F
, on
page 6). There are five available screens:
Status (see page 12)
Network (see page 13)
Display (see page 15)
Audio (see page 16)
Advanced (see page 17)
To navigate between different screens, press the
Menu icon in the top left corner.
The screen selection menu opens over the current screen, which is grayed out. The
menu has five buttons, corresponding to the five available screens:
Status
Exit
INFO
Model
Part Number
Firmware Version
PoE
TLP Pro 320M
60-1451-02
1.00.0010.b004
Active
NETWORK
DHCP Off
INF
O
o
e
P
art
N
um
b
er
Fi
rmw
a
r
e
Ve
r
sio
n
P
o
E
TLP
P
ro 320
M
60
-
14
5
1
-
02
1.
00
.
00
1
0
.
b00
4
A
ct
i
v
e
NETWORK
D
HCP
O
ff
Network
Display
Audio
Advanced
Status
Figure 7. Screen Selection Menu
The button for the screen that is currently selected is yellow with black text. The other screens
are gray with white text.
Press the name of the screen you wish to open.
There is also a red
Exit button in the top right corner of the screen. Press this button to apply
and save any changes and to close the menu screens.
TLP Pro 320M • Setup Menu 11
Status
This screen opens by default. To access the Status screen from any other part of the Setup
menu, press the
Menu icon in the top left corner and then press the Status button.
The image below shows the entire
Status screen. Because of size of the touchscreen, you
can only see part of the
Status screen at any time. Flick the touchscreen with your finger to
navigate up or down within the screen.
Status
Exit
INFO
Model:
Part Number:
Firmware Version:
PoE:
TLP Pro 320M
60-1451-02
1.03.0000.b001
Active
NETWORK
DHCP:
Hostname:
IP Address:
TLP-Pro-320M-AB-CD-EF
192.168.254.251
DISPLAY
Screen Resolution: 320x240
Sleep Timer: 5 Minutes
AUDIO
Master Volume: 80
Master Mute: Off
ADVANCED
Controller IP: 192.168.254.250
Storage Usage: 1/151 MB
Bootloader Version: 1.03.0000
Off
Figure 8. Status Screen
The
Status screen is a read-only screen that provides basic information about the
touchpanel. Each section of the screen shows a summary of the information on the other
screens. More information about each topic can be found on the Network (see page 13),
Display (see page 15), Audio (see page 16), and Advanced (see page 17) screens.
To navigate to the appropriate screen, click the light gray bar for that screen. Alternatively, you
can use the Menu icon in the top left corner.
The colored circle in the
Network panel is green when there is a network connection or amber
if there is no connection. The colored circle in the Advanced panel is green when a control
processor is connected or amber if none is connected.
TLP Pro 320M • Setup Menu 12
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Extron TLP Pro 300M Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues