Zephyr ZPIE24AG Hood User Manual

Catégorie
Hottes
Taper
Hood User Manual

Ce manuel convient également à

Use, Care, and Installation Guide
www.zephyronline.com
Model number:
Serial Number:
NOV17.0701 © Zephyr Ventilation LLC.
Pisa
ZPI-E24AG
ZPI-E24AG290
ZPI-E30AG
ZPI-E30AG290
ZPI-E36AG
ZPI-E36AG290
ZPI-E24AW
ZPI-E24AW290
ZPI-E30AW
ZPI-E30AW290
www.zephyronline.com
1
SAFETY NOTICE .......................................................................... 2-3
LIST OF MATERIALS
................................................................. 4
INSTALLATION
Ducting Calculation Sheet
....................................... 5
Mounting Height & Clearance
................................ 6
Ducting Options
........................................................... 7
+RRG6SHFL¿FDWLRQV
................................................... 8
Preparing the Cabinet
............................................... 9
Horizontal Ducting Conversion
.............................. 10
Installing the Hood
...................................................... 11 - 13
Recirculation Kit
........................................................... 14
FEATURES & CONTROLS
Slide Controls
................................................................ 15
MAINTENANCE
Hood and Filter Cleaning
......................................... 16
Lights
................................................................................ 17
WIRING DIAGRAMS
................................................................... 18
TROUBLESHOOTING
................................................................ 19
LIST OF PARTS AND ACCESSORIES
.............................. 20
WARRANTY .................................................................................... 21
PRODUCT REGISTRATION
.................................................... 22
Table of Contents
Important Safety Notice
READ AND SAVE THESE INSTRUCTIONS
2
www.zephyronline.com
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE.
WARNING
TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer.
b. Before servicing or cleaning unit, switch power off at service panel and lock panel to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service
panel.
CAUTION
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. Take care when using cleaning
agents or detergents. Suitable for use in household cooking area.
WARNING
TO REDUCE THE RISK OF RANGE TOP GREASE FIRE:
a. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly
on low or medium settings.
E $OZD\VWXUQKRRG21ZKHQFRRNLQJDWKLJKKHDWRUZKHQÀDPLQJIRRG
F &OHDQYHQWLODWLQJIDQVIUHTXHQWO\*UHDVHVKRXOGQRWEHDOORZHGWRDFFXPXODWHRQIDQRU¿OWHU
d. Use proper pan size. Always use cookware appropriate for the size of the surface element.
H .HHSIDQ¿OWHUVDQGJUHDVHODGHQVXUIDFHVFOHDQ
f. Use high setting on hood only when necessary.
g. Don’t leave hood unattended when cooking.
h. Always use cookware and utensils appropriate for the type of and amount of food being prepared.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE, OBSERVE THE FOLLOWING:
D 6027+(5)/$0(6ZLWKDFORVH¿WWLQJOLGFRRNLHVKHHWRUPHWDOWUD\WKHQWXUQRIIWKHEXUQHU%(&$5()8/7235(9(17%8516
,IWKHÀDPHVGRQRWJRRXWLPPHGLDWHO\(9$&8$7($1'&$//7+(),5('(3$570(17
b. NEVER PICK UP A FLAMING PAN – You may be burned.
c. DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.
d. Use an extinguisher ONLY if:
1. You know you have a Class ABC extinguisher, and you already know how to operate it.
 7KH¿UHLVVPDOODQGFRQWDLQHGLQWKHDUHDZKHUHLWVWDUWHG
 7KH¿UHGHSDUWPHQWLVEHLQJFDOOHG
 <RXFDQ¿JKWWKH¿UHZLWK\RXUEDFNWRDQH[LW
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
D ,QVWDOODWLRQZRUNDQGHOHFWULFDOZLULQJPXVWEHGRQHE\TXDOL¿HGSHUVRQVLQDFFRUGDQFHZLWKDOODSSOLFDEOHFRGHVDQGVWDQGDUGV
,QFOXGLQJ¿UHUDWHGFRQVWUXFWLRQ
E 6XI¿FLHQWDLULVQHHGHGIRUSRZHUFRPEXVWLRQDQGH[KDXVWLQJRIJDVHVWKURXJKWKHÀXHFKLPQH\RIIXHOEXUQLQJHTXLSPHQWWRSUHYHQW
back-drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National
)LUH3URWHFWLRQ$VVRFLDWLRQ1)3$DQGWKH$PHULFDQ6RFLHW\IRU+HDWLQJ5HIULJHUDWLRQDQG$LU&RQGLWLRQLQJ(QJLQHHUV$6+5$(DQG
the local code authorities.
c. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
d. Ducted fans must always vent to the outdoors.
e. NEVER place a switch where it can be reached from a tub or shower.
f. Make sure the power is off before installing, wiring or maintenancing.
Important Safety Notice
3
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
CAUTION
7RUHGXFHULVNRI¿UHDQGWRSURSHUO\H[KDXVWDLURXWVLGH'RQRWYHQWH[KDXVWDLULQWRVSDFHVZLWKLQZDOOVFHLOLQJV
attics, crawl spaces or garages. Hood not intended for installation over an outdoor grill.
OPERATION
$OZD\VOHDYHVDIHW\JULOOHVDQG¿OWHUVLQSODFH:LWKRXWWKHVHFRPSRQHQWVRSHUDWLQJEORZHUVFRXOGFDWFKRQWRKDLU¿QJHUV
and loose clothing.
The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation,
maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to
negligence and the warranty of the unit automatically expires due to improper maintenance.
*NOTE: Please check www.zephyronline.com for revisions before doing any custom work.
ELECTRICAL REQUIREMENTS
Important:
Observe all governing codes and ordinances.
It is the customer’s responsibility:
 7RFRQWDFWDTXDOL¿HGHOHFWULFDOLQVWDOOHU
- To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70
latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and
all local codes and ordinances.
,IFRGHVSHUPLWDQGDVHSDUDWHJURXQGZLUHLVXVHGLWLVUHFRPPHQGHGWKDWDTXDOL¿HGHOHFWULFLDQGHWHUPLQHWKDWWKH
ground path is adequate.
Do not ground to a gas pipe.
&KHFNZLWKDTXDOL¿HGHOHFWULFLDQLI\RXDUHQRWVXUHWKHUDQJHKRRGLVSURSHUO\JURXQGHG
Do not have a fuse in the neutral or ground circuit.
*National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575
This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit
protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to
Electrical Diagram on product.
$FDEOHORFNLQJFRQQHFWRUQRWVXSSOLHGPLJKWDOVREHUHTXLUHGE\ORFDOFRGHV&KHFNZLWKORFDOUHTXLUHPHQWVSXUFKDVH
and install appropriate connector if necessary.
4
www.zephyronline.com
(3) Wire Nuts
(1) Suction Cup
(1) 6” round damper (pre-installed)
(1) hardware package
PARTS SUPPLIED
HARDWARE PACKAGE CONTENTS
PARTS NOT SUPPLIED
- Ducting, conduit and all installation tools
- Cable connector (if required by local codes)
- Recirculation Kit
(2) halogen lights, GU-10 50W
(1) mesh filter
(2) M4 x 1”
(1) hood body with sliding glass
(1) filler panel
(4) M3.5x10
(4) M4 x 16mm
(2) upper installation brackets
(2) lower installation brackets
(24” model only)
(2) M4 x 8
(4) 3/16 x 3/8”
(4) 3/16 x 40
(24” model only)
(24” model only)
(24” model only)
List of Materials
5
Duct pieces
Tot a l
Equivalent number
length x used =
3- 1/4” x 10”
Rect.,
straight
1 Ft. x ( ) =
Ft.
3- 1/4” x 10”
Rect. to
6” round
transition
5 Ft. x ( ) =
Ft.
3- 1/4” x 10”
Rect. to
6” round
transition
90
0
elbow
20 Ft. x ( ) =
Ft.
6”, 7”, 8”, 10”
Round,
90
0
15 Ft.
x ( ) =
Ft.
6”, 7”, 8”, 10”
Round,
45
0
9 Ft. x ( ) =
Ft.
Ft.
6”, 7”, 8”, 10”
Round,
straight
1 Ft. x ( ) =
Ft.
Subtotal column 1 =
Duct pieces
Tot a l
Equivalent number
length x used =
6”, 7”, 8”, 10”
Round, wall
cap with
damper
30 Ft. x ( ) =
Ft.
Ft.
Ft.
Ft.
6”, 7”, 8”, 10”
Round
roof cap
30 Ft. x ( ) =
Ft.
Subtotal column 2 =
Subtotal column 1 =
Total ductwork =
Maximum Duct Length: For satisfactory air movement,
the total duct length
should not exceed 100 equivalent feet.
6” round to
3- 1/4” x 10”
rect.
transition
1 Ft. x ( ) =
Ft.
6” round to
3- 1/4” x 10”
rect.
transition
90
0
elbow
16 Ft. x ( ) =
Ft.
7” round to
3 1/4” x 10”
rect.
transition
8 Ft. x ( ) =
Ft.
7” round to
3- 1/4” x 10”
rect.
transition
90
0
elbow
23 Ft. x ( ) =
Ft.
elbow
elbow
7” to 6” or
8” to 7” Round
tapered
reducer
25 Ft. x ( ) =
Ft.
3- 1/4” x 10”
Rect. 90
0
elbow
15 Ft. x ( ) =
Ft.
3- 1/4” x 10”
Rect. 45
0
elbow
9 Ft. x ( ) =
Ft.
3- 1/4” x 10”
Rect. 90
0
flat elbow
24 Ft. x ( ) =
Ft.
3- 1/4” x 10”
Rect.
wall cap
with damper
30 Ft. x ( ) =
Ft.
Ft. x ( ) =
Ft.
15
6”, 7“, 8”
Round
in-line
damper
Installation – Ducting Calculation Sheet
6
www.zephyronline.com
DUCTING
A minimum of 6” round ducting must be used to
PDLQWDLQPD[LPXPDLUÀRZHI¿FLHQF\
Always use rigid type metal ducts only. Flexible
GXFWVFRXOGUHVWULFWDLUÀRZE\XSWR
Use calculation worksheet to compute total duct
work.
ALWAYS, when possible, reduce the number of
transitions and turns. If a long duct run is required,
increase duct size from 6” to 7” or 8”.
If turns or transitions are required: Install as far
away from opening and as far apart, between 2,
as possible.
36”
24” min.
32” max.
Mounting height from top of cooking surface to
bottom of hood should be no less than 24” and no
more than 32”.
It is important to install the hood at the proper
mounting height. Hoods mounted too low could
UHVXOWLQKHDWGDPDJHDQG¿UHKD]DUGZKLOHKRRGV
mounted too high will be hard to reach and will
ORVHSHUIRUPDQFHDQGHI¿FLHQF\
If available, also refer to range manufacturer’s
height clearance requirements and recommended
hood mounting height above range. Always check
your local codes for any differences.
DAMAGE-SHIPMENT / INSTALLATION:
 3OHDVHIXOO\LQVSHFWXQLWIRUGDPDJHEHIRUH
installation.
 ,IWKHXQLWLVGDPDJHGLQVKLSPHQWUHWXUQ
the unit to the store in which it was bought
for repair or replacement.
 ,IWKHXQLWLVGDPDJHGE\WKHFXVWRPHU
repair or replacement is the responsibility
of the customer.
 ,IWKHXQLWLVGDPDJHGE\WKHLQVWDOOHU
LIRWKHUWKDQWKHFXVWRPHUUHSDLURI
replacement must be made by arrangement
between customer and installer.
Installation – Mounting Height & Clearance
7
WARNING FIRE HAZARD
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages.
All exhaust must be ducted to the outside.
Use single wall rigid Metal ductwork only.
)DVWHQDOOFRQQHFWLRQVZLWKVKHHWPHWDOVFUHZVDQGWDSHDOOMRLQWVZFHUWL¿HG6LOYHU7DSHRU'XFW7DSH
Ducting Options Example
Installation – Ducting Options
soffit or crawl space
roof pitch w/
flashing & cap
ductless
recirculating
w/ gravity damper
side wall cap
ductless
recirculating
soffit
8
www.zephyronline.com
Installation – +RRG6SHFL¿FDWLRQV
TOP
FRONT
SIDE
6
CL
"
3
7/16
3/4”
23 7/8”(24”), 29 7/8”(30”), 35 7/8”(36”)
19
1
1/2”
9
9/16
11
1/4
9/16”
5
3/16” (30”)
11-
15/16
” - 18-
3/4
11
1/8”
13/16”
9 7/8
1
1/8
4
/15 16”
closed open
3 7/16
3/8” -
2 1/4"*
*adjustable rear
filler panel
C/L
3
7/16
11
1/4
Ø6”
BACK
8
3/16” (36”)
11/16”1
2
3/16” (24”)
9
7 3/4
7”
10-
1/8”
19-
7/8”
C/L
1-
15/16”
*11-
1/2”
*6-
3/16”
7”
Installation – Preparing the Cabinet
Fig.2
front edge
glass handle
1. Determine and mark center line on wall and cabinet bottom with a pencil.
2. If the cabinet bottom is recessed, wood blocking must be installed to ensure proper
DOLJQPHQWRIWKHKRRGZLWKWKHFDELQHWERWWRP:RRGEORFNLQJVKRXOGEHÀXVK 
within cabinet bottom.
3. Follow the dimensions in Fig.1 and cut-out the bottom of your cabinet to create an opening
IRUWKHKRRGWR¿WWKURXJK)RUIUDPHOHVVFDELQHWPHDVXUH´IURPWKHIURQWRI
cabinet door. For framed cabinet measure 1-15/16” from front of cabinet bottom.
Fig.1
* Dimension used for rear ducting option
10
www.zephyronline.com
6” ROUND VERTICAL TO HORIZONTAL DUCTING CONVERSION
Installation – Horizontal Conversion
5HPRYHDOXPLQXPPHVK¿OWHU)URPLQVLGHWKHKRRG
disconnect blower plug located toward the right side
interior of hood body.
5HPRYHVFUHZVIURPWRSRIKRRGDQGVFUHZVIURP
back of hood attaching blower plate to hood body.
5HPRYHEORZHUDQGEORZHUSODWHIURPKRRGERG\DQG
reposition blower to hood body so blower collar protrudes
from back of hood body. Re-install blower plate to hood
ERG\XVLQJWKHVFUHZVSUHYLRXVO\UHPRYHGIURPVWHS
Re-connect blower plug.
11
Installation – Installing the Hood
WARNING: Electrical wiring must be done by a qualified person(s) in
accordance with all applicable codes and standards. This range hood must be
properly grounded. Turn off electrical power at service entrance before wiring.
!
3UHSDUHHOHFWULFDOZLULQJDQGGXFWLQJLQFDELQHW/RFDWLRQRIMXQFWLRQER[DQGEORZHURXWOHWFDQEHIRXQGRQSDJH
Fig.3
2SHQFDELQHWGRRUV/LIWUDQJHKRRGDQGVOLGHLWWKURXJK
the opening located in the bottom of the cabinet, Fig.3.
Make sure opening matches the dimensions on page 9,
Fig.1.
7KHUHDUHVSULQJFOLSVORFDWHGRQWKHOHIWDQGULJKWVLGHV
of the hood body which will temporarily hold the hood in
place, Fig.4.
Fig.4
Fig.5
24” Models Only. Secure upper brackets to left and
ULJKWVLGHVRIKRRGERG\E\XVLQJ[´VFUHZVIRU
HDFKEUDFNHW)LJ0DNHVXUHWKHFDSWLYHQXWVFUHZV
holes on the bracket are facing downward.
24” Models Only. Place lower installation brackets
under upper installation brackets located on left and right
sides of hood body, Fig.6. Note: The wider portion of the
lower installation bracket should be at the bottom.
Fig.6
12
www.zephyronline.com
Installation – Installing the Hood
30” & 36” Models Only. Secure hood body to cabinet
EDVHE\0[PPVFUHZVWKURXJKWKHERWWRPRI
range hood.
A
6HFXUH´ZRRGVFUHZV$LQWRWKHVFUHZKROHVRQ
WKHOHIWDQGULJKWVLGHVRIWKH¿OWHURSHQLQJ
Fig.7
24” Models Only)URPLQVLGHWKHKRRGVHFXUH
M4x8 screw into each lower installation bracket. The
position of this screw is adjustable to accomodate various
cabinet bottom thicknesses, Fig.7.
24” Models Only,QVWDOO[VFUHZVLQWRWKH
captive nuts of each upper installation bracket. Tighten
screws to adjust the height of the range hood until there
is no gap between the cabinet and front edge of the hood,
Fig.8.
Fig.8
Installation – Installing the Hood
13
3ODFH´URXQGGXFWLQJRYHUEORZHUFROODUDQGVHFXUH
with aluminum duct tape. If using hood in ductless
recirculating mode turn to page 14.
,QVWDOOHOHFWULFDOZLULQJ1RWH$FDEOHORFNQRW 
LQFOXGHGPD\EHUHTXLUHGE\ORFDOFRGHV&KHFN
with local requirements and codes, purchase and install
appropriate connector if necessary.
Make sure no packing material is inside hood. Power
up hood check for leaks around duct tape and verify all
functions.
Fig.9
0HDVXUHGLVWDQFHEHWZHHQEDFNRIUDQJHKRRGDQGZDOO
LIDQ\DQGFXW¿OOHUSDQHOWRWKHDSSURSULDWHGHSWK
using a utility knife or heavy-duty scissors.
,QVWDOO¿OOHUSDQHOWRERWWRPRIKRRGE\[
VFUHZVIRU´PRGHORU[VFUHZVIRU´PRGHO
14
www.zephyronline.com
Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed.
When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust
IURPFRRNLQJDUHGUDZQDQG¿OWHUHGE\DQRSWLRQDOFKDUFRDO¿OWHU7KHDLULVWKHQSXUL¿HGDQGUHFLUFXODWHGEDFN
within the home.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct
ZRUNLISRVVLEOH7KHKRRGLVPRVWHIIHFWLYHDQGHI¿FLHQWDVDQH[KDXVWKRRG2QO\ZKHQWKHH[KDXVWRSWLRQ
is not possible should you recourse to converting the hood into a recirculating hood.
:KHQFRQYHUWHGWREHDUHFLUFXODWLQJKRRGDFKDUFRDO¿OWHULVUHTXLUHGRQWRSRIWKHGHFRUDWLYHPHVK¿OWHU
2UGHUDFFRUGLQJWRLWVSDUWQXPEHUEHORZ7KHGHFRUDWLYHPHVK¿OWHULVLQWHQGHGWRFDSWXUHUHVLGXHIURP
FRRNLQJDQGWKHRSWLRQDOFKDUFRDO¿OWHUKHOSVWRSXULI\IXPHVH[KDXVWHGIURPFRRNLQJIRUUHFLUFXODWLRQ
RECIRCULATING KIT (REQUIRED IF NOT DUCTED OUTSIDE THE HOME)
.LWLQFOXGHVFKDUFRDO¿OWHUEUDFNHWVDQGUHWXUQDLUYHQW
Hood Model Part No. Filters in Pkg.
ZPI ZRC-00PI 1
1. Purchase recirculating kit per the part number above.
 5HPRYHGHFRUDWLYHPHVK¿OWHUIURPKRRGDQGSODFHFKDUFRDO¿OWHURQWRSRI
PHVK¿OWHU6HFXUHFKDUFRDO¿OWHUE\&FOLSVIURP=5&3,UHFLUFXODWLRQ
NLW&FOLSVIRUHDFKHQORQJDWHGVLGHRIFKDUFRDO¿OWHU)LJ
5HLQVWDOOGHFRUDWLYHPHVK¿OWHU
Charcoal Filter Replacement
Hood Model Part No. Qty to Order
ZPI Z0F-C0PI 1
4. In order to recirculate the air properly, a return air vent must be installed to
allow recycled air to be returned to the kitchen, Fig. 11. Ducting must be run
from the blower to the return air vent. The return air vent can be positioned
RQWRSRIWKHFDELQHWRULQDVRI¿WFHLOLQJ
 &KDUFRDO¿OWHUPXVWEHUHSODFHGDIWHUHYHU\KRXUVRIXVHRUDSSUR[LPDWHO\
HYHU\WRPRQWKVEDVHGRQDQDYHUDJHGDLO\XVHRIKRXURIFRRNLQJWLPH
Fig.12
Fig.11
Installation – Recirculating Kit
15
0 I II III
Blower On/Off Speed Selection
1
Lights Off/Dim/Bright
2
0 I II
BLOWER ON/OFF/SPEED SELECTION
0 is off, I is low speed, II is medium speed and III is high speed.
LIGHTS OFF/DIM/BRIGHT
0 is off, I is dim, and II is bright.
1
2
NOTE: Blower and lights will automatically shut off when the glass is closed
and turn back on when the glass is opened.
Blower and lights will not operate when the glass is closed.
Features & Controls – Slide Controls
16
www.zephyronline.com
SURFACE MAINTENANCE:
Do not use corrosive detergents, abrasive detergents or oven cleaners.
Do not use any product containing chlorine bleach or any product containing chloride.
Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface.
Cleaning Stainless Steel
&OHDQSHULRGLFDOO\ZLWKZDUPVRDS\ZDWHUDQGFOHDQFRWWRQFORWKRUPLFUR¿EHUFORWK$OZD\VUXELQWKH
direction of the stainless steel grain. To remove heavier grease build up use a liquid degreaser detergent.
After cleaning use a non-abrasive stainless steel polish/cleaners, to polish and buff out the stainless luster
DQGJUDLQ$OZD\VVFUXEOLJKWO\ZLWKFOHDQFRWWRQFORWKRUPLFUR¿EHUFORWKDQGEXIILQWKHGLUHFWLRQRIWKH
stainless steel grain.
Decorative Mesh Filters
7KHPHVK¿OWHULQVWDOOHGE\WKHIDFWRU\LVLQWHQGHGWR¿OWHURXWUHVLGXHDQGJUHDVHIURPFRRNLQJ,WQHHGQRW
be replaced on a regular basis but is required to be kept clean.
Filter should be cleaned after every 30 hours of use or once a month.
Remove and clean by hand or in dishwasher
on low heat. Spray degreasing detergent and
leave to soak if heavily soiled.
'U\¿OWHUDQGUHLQVWDOOEHIRUHXVLQJKRRG
Replacing Mesh Filter
6KRXOG¿OWHUZHDURXWGXHWRDJHDQG
prolonged use, replace with the following part
number:
Hood Model: Part No. Qty. to Order.
ZPI 50200054 1
5HSODFHDQ\GDPDJHG¿OWHUWKDWKDVSXQFWXUHG
or broken mesh or damaged frame.
7RUHPRYHGHFRUDWLYHPHVK¿OWHU
3XVKLQ¿OWHUODWFK
7LOW¿OWHUGRZQDQGUHPRYHIURPKRRG
1
2
Maintenance – Hood and Filter Cleaning
17
REPLACING LIGHT BULBS
CAUTION: Light bulb becomes extremely hot when turned on.
DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns.
Make sure all power is turned off and bulbs are not hot.
Remove by turning bulb counter-clockwise. Note: Bulb does not unscrew; it turns 60 degrees,
stops and falls out.
,IEXOEVDUHGLI¿FXOWWRWXUQGXHWRSURORQJHGXVH¿UPO\DWWDFKDJODVVVXFWLRQFXSDSSUR[LPDWHO\WKHGLDPHWHURI
the bulb or use a rubber/latex glove to grip the bulb and turn counter clockwise.
5HSODFHPHQWEXOEVDUHDYDLODEOHDWVSHFLDOW\OLJKWLQJVWRUHV3XUFKDVHW\SH05*8:KDORJHQ
For Zephyr part numbers please turn to page 20 of the manual.
Maintenance – Lights
18
www.zephyronline.com
Wiring Diagrams
VOLTS
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Zephyr ZPIE24AG Hood User Manual

Catégorie
Hottes
Taper
Hood User Manual
Ce manuel convient également à

dans d''autres langues