Owner’s Manual — Phoenix Axial Air Mover
Installation, Operation & Service Instructions
1
www.thermastor.com • sales@thermastor.comToll-Free 1-800-533-7533
Read and Save These Instructions
Phoenix Axial Air Mover
TS-285
The Phoenix Axial Air Mover is the industry’s only Air Mover specifically engineered with patent pending
FOCUSTM Technology. FOCUSTM Technology revolutionizes evaporative drying by producing air velocities
greater than competitive product offerings. This highly focused air flow is directed towards the restoration
industry’s problematic drying areas namely, carpet and pad, sub-floor, sill plate and walls. No other fan
dries the sill plate as quickly! Finally, the Phoenix Axial Air Mover with FOCUSTM Technology sustains these
air velocities further than any other Axial Air Mover.
The Phoenix Axial Air Mover includes a 2-speed motor delivering a focused
airstream of approximately 3000 cfm, lightweight stackable
enclosure designed to fit existing vehicle rigging, on-board duplex
GFCI outlet, circuit breaker, superior cord management and hour
meter.
Conventional air movers create a circular air jet. With a circular
air jet the only way to get air into the square corner is to point
the fan towards the corner. This angle toward the wall wastes
valuable air velocity and throw distance. FOCUSTM Technology
creates an air jet with a square corner, resulting in optimized
drying ability. In addition, the Axial Air Mover features built in
4.5° positioning which increases the fans ability to dry.
Dry fast, smart and profitably with Phoenix.
Phoenix Axial Air Mover
Approximately 3000 CFM air flow directed where
you need it.
Operator interface conveniently located for easy
access, featuring: power indicator lamp, large three-
position switch, circuit breaker, GFCI outlet, and
hour meter.
Daisy-chain up to four Phoenix Axial Air Movers on a
single circuit.
Integral circuit breaker eliminates nuisance trips to
the breaker box.
Axial Air Mover itself is also GFCI protected.
Units interlock for ease of stacking during storage
and handling.
Weighs 2.5 lbs less than competitive units.
Linear low density polyethylene construction.
Low bearing temperatures increase motor life.
Permawick®, low maintenance, long life lubrication.
Specifications subject to change without notice.
Revised 1/07
Phoenix Axial Air Mover
PN 4025200
PO Box 8680 • Madison, WI 53708
2
www.thermastor.com • sales@thermastor.comToll-Free 1-800-533-7533
1 Safety Information
Do not operate the unit with a cut or frayed power cord.
Replace cord if it becomes damaged.
Do not unplug the unit by pulling on the cord. Grasp the
plug firmly and pull it out of the wall socket or power
receptacle.
Always use a grounded outlet.
Never operate electrical equipment in standing water.
Never operate with the safety grills removed. Personal
injury may result.
Do not stick your fingers or other objects through the
safety grills.
Do not restrict airflow to the unit. This may cause the
unit to overheat.
Unit should never be serviced or cleaned while it is
plugged in.
Do not plug more than 9.0 amps total into the GFCI
outlet.
Do not sit or stand on the unit or use as a shelf or
table.
Check GFCI protection before each use by pushing
“test” button. If operating properly, “reset” button will
pop out.
Before leaving an Axial Air Mover unattended, ensure
children do not have access to the equipment. Do not
allow children to play with or near the unit or in its air
flow.
To reduce the risk of fire or electric shock, do not use
this air mover with any solid-state speed control device.
LIRE ET CONSERVER CES INSTRUCTIONS
Risque de choc électrique Peut causer des blessures ou
la mort. Débrancher toutes les alimentations en courant
électrique à distance avant l’entretien ou le nettoyage.
Ne pas utiliser l’appareil avec un cordon d’alimentation
coupé ou effiloché.
Ne pas débrancher l’appareil en tirant sur le cordon.
Tenir la fiche fermement et la tirer hors de la prise
murale ou la prise d’alimentation électrique.
Toujours utiliser une prise mise à la terre.
Ne jamais utiliser l’équipement électrique dans de l’eau
stagnante.
Ne jamais utiliser sans les grilles de protection. Des
blessures risquent d’en résulter.
Ne pas passer les doigts ou d’autres objets dans les
grilles de protection.
Ne pas diminuer le débit d’air arrivant jusqu’à l’appareil.
L’appareil risque de trop chauffer.
Ne pas brancher plus de 9 ampères au total au
différentiel.
Ne pas s’asseoir ou se tenir debout sur l’appareil; ne
pas l’utiliser comme étagère ou table.
Table of Contents
Introduction ...............................................................1
FOCUSTM Technology Features and Benefits ....................1
1. Safety Information .................................................2
2. Intended Application ..............................................3
3. Safety Certifications ...............................................3
4. Specifications ........................................................3
5. Power Requirements ..............................................3
5.1 Daisy-Chaining ................................................3
5.2 Recommended Use .........................................3
5.3 Integrated Cord Wrap .......................................4
6. Applications ..........................................................4
6.2 Placement ......................................................4
6.3 Orientation of Directional Drying .......................5
7. Operating Instructions ............................................5
8. Operator Panel Features .........................................5
8.1 Run-Time Hour Meter .......................................5
8.2 12 Amp Circuit Breaker ....................................5
8.3 Power Indication Lamp .....................................6
8.4 3-Position Drying Selector Switch ......................6
8.5 GFCI Protection ...............................................6
9. Maintenance .........................................................6
9.1 Servicing ........................................................6
9.2 Motor Lubrication ............................................6
9.3 Cleaning .........................................................7
10. Replacement Parts and Optional Accessories ...........7
11. Wiring Diagram .....................................................7
12. Warranty ...............................................................9
Serial No. ___________________________
Purchase Date ______/______/_____
Dealer’s Name ___________________________________
3
www.thermastor.com • sales@thermastor.comToll-Free 1-800-533-7533
Vérifier la protection du différentiel avant chaque
utilisation en appuyant sur le bouton “ test “. Si
l’appareil fonctionne correctement, le bouton “ reset “
ressort.
Avant de laisser un appareil aéraulique axial sans
surveillance, s’assurer que les enfants n’ont pas accès
à l’équipement. Ne pas laisser les enfants jouer avec
l’appareil ou à proximité de l’appareil ou dans l’air qu’il
projette.
Pour réduire le risque d’incendie ou de choc électrique,
ne pas utiliser ce ventilateur avec un dispositif de
commande de vitesse à semi-conducteurs.
2 Intended Application
The Phoenix Axial Air Mover has changed the drying
industry by minimizing overall drying time on water
restoration jobs. The Phoenix Axial Air Mover uses patent
pending FOCUS Technology to maximize air velocity across
floors and along walls for longer distances. By maximizing
the air velocity, water evaporates more quickly from the
carpet, pad, sub-floor, wall, and sill plate.
3 Safety Certifications
The Phoenix Axial Air Mover (P/N 4025200) conforms to
UL STD 507. Certified to CAN/CSA STD C22.2 No. 113.
4 Specifications
Part No. 4025200
Power 1/4 hp 1-phase 110/120 VAC 2-speed
4-pole, PSC Electric Motor.
CFM Approximately 3000
Cord 20 ft Power Cord
Outlet 15A UL Rated GFCI Duplex Receptacle
Current Draw 2.5 Amps
Voltage 115 VAC
Warranty Year One - 100% parts and labor
(all components)
Year Two - 100% parts only (all components)
Years Three through Seven - Only materials
and workmanship of the housing are covered.
Dimensions
Cabinet
Width 19.9”
Height 19.5”
Depth 15.2”
Weight 29.5 Lbs
5 Power Requirements
5.1 Daisy Chaining
The Phoenix Axial Air Mover draws 2.5 amps. The 12 amp,
on-board circuit breaker will allow four (4) Phoenix Axial Air
Movers on one circuit. When daisy-chaining the Phoenix
Axial Air Mover, turn on one Phoenix Axial Air Mover at a
time to prevent excessive current inrush caused by four
units starting at once.
A ground fault in the Phoenix Axial Air Mover or anywhere
on the circuit will cause the Axial Air Mover’S GFCI to trip.
After rectifying the ground fault, reset the GFCI by pressing
the reset button.
Figure 1: Too many Axial Air Movers daisy-chained
Figure 2: Duplex GFCI use
5
15 Amp
Outlet
15 Amp
Outlet
15 Amp
Outlet
Phoenix 200 MAX
Phoenix Mini-Guardian
5.2 Recommended Use
Recommended use(s) of on-board duplex GFCI are shown.
Note: Standard 115 VAC electrical outlets.
4
www.thermastor.com • sales@thermastor.comToll-Free 1-800-533-7533
55.3 Integrated Cord Wrap
The Phoenix Axial Air Mover features integrated cord
management. Wrap the cord around the cord wrap as
shown and secure the cord with the clasp on the plug.
the FOCUS Technology corner.
The Axial Air Mover sustains
this air flow for more than 20
feet and maximizes the air
velocity across the floor and
along the wall when placed
the at 4.5° angle from the
wall.
By touching the front edge
of the output side of the
axial air mover against the
wall and rotating the rest of
the unit against the wall, the
restoration professional will
place the axial air mover at
4.5° due to the housing’s
built-in design. Industry
experts agree placing Axial Air
Movers 45° angle to the wall
wastes air flow and reduces
the performance by forcing air
up the wall.
2500
2000
1500
1000
500
0
0 Feet 5 10 15 20 25
Air Velocity (fpm)
Figure 5: 4.5° to wall
as shown
Immediate high velocity air flow
at the outlet of the fan.
The best set up angle for quickly and completely drying the
sill plate is 4.5°. Set-up angles greater than 4.5° may be
used under unique circumstances such as corner air flow
and structure variations. Set-up angle should never exceed
23°.
6.3 Orienting of Directional Drying System
The axial air mover dries in counter-clockwise and
clockwise directions for optimum ease of use. The axial
air mover ships with rubber feet on one side of the unit for
counter-clockwise drying.
When the water restoration professional needs to employ
clockwise drying (such as the need to dry a door jamb),
simply rotate the axial air mover 90° so the FOCUS
Technology corner points toward the door jamb and floor
for the clockwise drying.
Figure 6: Placement for counter-clockwise drying
Figure 3: Cord wrap
6 Applications
6.1 Sizing for Water Restoration Jobs
Current industry standards call for one air mover per 10-16
linear feet of wall space, dependent upon the Class of wa-
ter damage. For commercial structures, the industry stan-
dard calls for one air mover for every 50-60 square feet.
The water restoration industry based these estimates on
the air mover technology available when writing the stan-
dards. Following these equipment-sizing standards when
using the Phoenix Axial Air Mover will result in dramatically
faster drying times. If the restoration professional desires
to merely achieve industry standard drying times, he can
use fewer Phoenix Axial Air Movers than standard equip-
ment standards allow.
6.2 Placement
Current industry guidelines suggest placing air movers at
a 15° - 45° angle to wall. These guidelines apply to air
movers without FOCUS Technology. FOCUS Technology
allows the restoration professional to place the Phoenix
Axial Air Mover at an angle nearly parallel to the wall.
The test graph shown below depicts immediate air flow at
Figure 4: Airflow of the Phoenix Axial Air Mover measured
3.5” parallel to wall.
5
www.thermastor.com • sales@thermastor.comToll-Free 1-800-533-7533
Figure 7: Birds eye view of room set-up
GFCI: Added Protection
High Speed: “Ultra”
Drying Power
Low Speed:
Quiet Operation
12 Amp
Circuit Breaker
AC Indicator Lamp Stainless Steel
Control Panel
Hour Meter
Figure 9: Axial Air Mover Operator Panel
If the water restoration professional dries in the clockwise
direction often, we suggest attaching the two (factory
provided) rubber feet into the threaded holes on the side
of the unit. By attaching the rubber feet and creating the
optimal downward angle of 4.5°, the Phoenix Axial Air
Mover will maximize air velocity across the floor and wall
when drying in the clockwise direction.
7 Operating Instructions
The Phoenix Axial Air Mover as packaged is ready to be put
into service. Inspect the unit completely for any shipping
damage. Place the unit on the ground. Check the GFCI to
ensure it is not tripped. Orient the unit so the desired air
flow direction is the same as the arrow indicator sticker in
the FOCUS Technology corner on the interior of the unit.
Plug the unit into a grounded outlet and select the drying
mode shown in Figure 9.
CAUTION: The Phoenix Axial Air Mover consumes 2.5 Amps.
Do not plug devices requiring more than 9.0 Amps of
current into the duplex outlet.
8 Operator Panel Features
8.1 Run-Time Hour Meter
The operator interface panel is equipped with an Automatic
LCD (Liquid Crystal Display) Hour meter. This hour meter
displays cumulative run time. The hour meter meets
IP65 for moisture and dust protection and is designed to
survive harsh restoration and water recovery applications.
The hour meter features non-volatile eeProm memory. This
type of memory cannot be erased, nor reset. This feature
ensures accurate time tracking.
The display can be used to track time-of-operation and
time-to-dry. Some restoration professionals use the hour
meters to help them establish hourly billables.
8.2 12 Amp Resettable Circuit Breaker
The 12 AMP thermal response resettable circuit breaker
protects the unit and devices connected to its duplex GFCI
outlet.
The circuit breaker is designed to sense the total current
draw through the circuit. The circuit breaker “trips” when
more than 12 amps of electrical current are drawn through
Counter
clockwise
airflow
pattern
Clockwise
airflow
pattern
Making use of factory installed feet (4) Making use of user installed feet (2)
Figure 8: Clockwise feet locations
User installed feet
for use during
clockwise drying
set-ups
Factory installed feet for use
during counter clockwise drying
6
www.thermastor.com • sales@thermastor.comToll-Free 1-800-533-7533
the device’s power cord. Should an over-current condition
occur, the Axial Air Movers’ on-board circuit breaker
prevents nuisance visits to a remote power junction box.
IMPORTANT: Total amperage of the Axial Air Mover plus all
devices plugged into the receptacle must not exceed 12
amps. The circuit breaker will not allow for loads in excess
of 12 amps, although there is a time delay before the
overloaded circuit is broken.
8.3 Power Indication Lamp
The red, sealed, high intensity AC voltage power indication
lamp allows operators to visually identify the operation
status of several Phoenix Axial Air Movers at a distance,
with a single glance. The power indication lamp will remain
lit when the AC power cord is plugged into a standard
“powered” AC power outlet and the 3-position drying
selector switch is in either the HIGH or LOW operation
position. The power indication lamp will remain unlit when
the AC power cord is unplugged, the 3-position drying
selector switch in the OFF position, the on-board GFCI
or 12 Amp circuit breaker is tripped, or the connected,
standard AC wall outlet power has been turned off.
8.4 3-Position Drying Selector Switch
The 3-position drying mode selector switch. This switch
is used to select the Phoenix Axial Air Mover’s mode of
operation. The 3 modes of operation are OFF, LOW or
HIGH.
IMPORTANT: When the Phoenix Axial Air Mover is plugged
into a standard “powered” wall outlet the Phoenix Axial Air
Mover’s duplex outlets are electrically “HOT” and AC voltage
is present.
OFF - The Phoenix Axial Air Mover is not drying. The
power indication lamp is unlit. If the unit is plugged into a
standard “powered” wall outlet all devices connected to
the unit’s duplex GFCI outlet receive AC voltage.
LOW - The Phoenix Axial Air Mover is in “Normal” Drying
mode. This mode provides rapid drying and very quiet
operation. The power indication lamp will be lit. All devices
connected to the devices duplex GFCI outlet will receive AC
voltage.
HIGH - The Phoenix Axial Air Mover is in “Fast” drying
mode. This mode provides the industries most rapid
drying while maintaining low noise operation. The power
indication lamp will be lit. All devices connected to the
devices duplex GFCI outlet will receive AC voltage.
8.5 GFCI Protection and the On-Board Duplex
VAC Outlet
The standard AC voltage outlet GFCI (Ground Fault Circuit
Interrupter) protection promotes operator safety in wet
applications. GFCI devices trip when a fault to electrical
“ground” is sensed.
It is recommended to check the GFCI protection prior to
operation. To check, push the “TEST” button located on
the GFCI duplex outlet. If operating properly the “RESET”
button on the GFCI outlet will pop out. Depending on your
Axial Air Movers specific equipment, a tripped GFCI may be
indicated by a small LED. The device can only be “RESET”
when the Axial Air Mover is connected to a wall outlet
providing standard voltage. This duplex AC outlet allows
the inter-connection of other AC powered devices. The sum
total amperage of all devices plugged into the receptacle
must not exceed 9 amps.
9 Maintenance
WARNING: Disconnect the unit from power before servicing,
lubrication or cleaning. Replace the wire safety grill after
servicing, lubrication or cleaning.
9.1 Servicing
Before each use inspect for damage, blocked inlet or
outlet, or any excess buildup of foreign material.
Inspect the GFCI to ensure it is not in a “tripped”
condition. Push “RESET” to reset the GFCI.
When the Phoenix Axial Air Mover is first turned on, check
for excessive vibration. If the unit vibrates excessively or if
blade rubs on housing, turn off the unit immediately. Have
a service technician inspect the unit to locate the problem.
Figure 10: Oil hole
locations. Access the
oil holes by removing
the protective grill(s)
and turning the unit
upside down.
7
www.thermastor.com • sales@thermastor.comToll-Free 1-800-533-7533
9.2 Motor Lubrication
Oil the unit every six months with 3 - 4 drops of SAE 20
weight non-detergent oil. Lubricate the motor with a drop of
oil after each washing.
IMPORTANT: The approved oil for lubrication is SAE 20
weight non-detergent oil, specifically designated for use
with electric motors.
9.3 Cleaning
The housing is made of a durable and washable
polyethylene. When cleaning, the use of solvents is NOT
recommended.
When washing inside the unit, disconnect the unit from its
power source. Protect the operator interface panel with
a cloth. Clean inner barrel, grills and blade. Wipe down
motor exterior with a damp cloth. If the motor gets wet
during cleaning, simply allow ample time for motor to dry
out completely before restarting. If you clean your device
frequently perform motor lubrication more frequently as
well.
If you wash the Axial Air Mover and do not plan to use it
within 24 hours, allow the fan to drip dry for 10 minutes
and then let run for 5 minutes. Before storing it, apply oil
as described above.
10 Replacement Parts and
Optional Accessories
Contact the factory at 1-800-533-7533 to order
replacement parts, or optional accessories
4025203 Breaker, CKT, 12A
4025204 Switch, Rocker, On-Off-On
4025205 Outlet, Duplex, GFCI, 15A
4025206 Grill, Safety, Intake
4025207 Grill, Safety, Exhaust
4025460 Axial Air Mover Stand
4025299 Stand Hardware Kit
Figure 11: Optional stand
allows the Axial Air Mover’s
air flow to be directed in a
360° range of movement.
(PN 4025460)
11 Wiring Diagram
Specifications subject to change without notice.
8
www.thermastor.com • sales@thermastor.comToll-Free 1-800-533-7533
This page intentionally left blank.
9
www.thermastor.com • sales@thermastor.comToll-Free 1-800-533-7533
Phoenix Axial Air Mover Limited Warranty
Warrantor:
Therma-Stor LLC
PO Box 8680
Madison, WI 53708
Telephone: 1-800-533-7533
Who Is Covered: This warranty covers Phoenix Axial Air Movers.
First Year Warranty: 100% parts and labor (all components)
Second Year Warranty: 100% parts only (all components)
Years Three through Seven: Only materials and workmanship of the housing are covered.
If a defect in materials or workmanship occurs within the warranty period, Therma-Stor LLC will
repair or replace the defect.
End-User Responsibilities: Warranty service must be performed by a servicer authorized by
Therma-Stor Products. To obtain warranty service you must obtain a return material authorization
(RMA). To obtain an RMA you must present proof of purchase or (lease), by use of a warranty
card, original sales receipt or other reasonable and reliable means.
To obtain an RMA call Therma-Stor LLC at the above number and ask for the Therma-Stor LLC
Service Department, which will then issue an RMA# and arrange for, at our option, either repair
or replacement.
Freight: Freight to and from the servicer is the responsibility of the end-user. The end-user is
responsible for normal care and proper return packaging.
Limitations and Exclusions: This warranty does not cover any defect, malfunction, etc. resulting
from misuse, abuse, lack of normal care, corrosion, freezing, tampering, modification,
unauthorized or improper repair or installation, accident, acts of nature or any other cause
beyond Therma-Stor LLC’s reasonable control.
If any Phoenix Axial Air Mover part is repaired or replaced, the new part shall be warranted for the
balance of original warranty (but all warranty periods will be extended by the period of time, if any,
that the Phoenix Axial Air Mover with FOCUS Technology is out of service while awaiting covered
warranty service).
Warranty service will be performed during normal working hours.
UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICABLE TO THE PHOENIX AXIAL
AIR MOVER OR ANY PART THEREOF, ALL OTHER WARRANTIES IMPLIED BY LAW, INCLUDING
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL ALSO EXPIRE. ALL
WARRANTIES MADE BY THERMA-STOR LLC ARE SET FORTH HEREIN, AND NO CLAIM MAY BE
MADE AGAINST THERMA-STOR BASED ON ANY ORAL WARRANTY. IN NO EVENT SHALL THERMA-
STOR LLC, IN CONNECTION WITH THE SALE, INSTALLATION, USE, REPAIR OR REPLACEMENT OF
ANY PHOENIX AXIAL AIR MOVER OR PART THEREOF BE LIABLE UNDER ANY LEGAL THEORY FOR
ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION WATER
DAMAGE (THE END USER SHOULD TAKE PRECAUTIONS AGAINST SAME), LOST PROFITS, DELAY,
OR LOSS OF USE OR DAMAGE TO ANY REAL OR PERSONAL PROPERTY.
Some states do not allow limitations on how long an implied warranty lasts, and some do not
allow the exclusion or limitation of incidental or consequential damages, so one or both of these
limitations may not apply to you.
Legal Rights: This warranty gives you specific legal rights, and you may also have other rights
which vary from state to state.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

Therma-Stor Products Group TS-285 Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues