LG S246KH Le manuel du propriétaire

Catégorie
Climatiseurs split-system
Taper
Le manuel du propriétaire

Ce manuel convient également à

P/NO : 3028A20402Z
www.lg.com
OWNER’S MANUAL
AIR CONDITIONER
Please read this manual carefully before operating
your set and retain it for future reference.
ENGLISH
FRANÇAIS
2 Room Air Conditioner
Room Air Conditioner Ownerʼs Manual
TABLE OF CONTENTS
FOR YOUR RECORDS
Write the model and serial numbers here:
Model #
Serial #
You can find them on a label on the side of each unit.
Dealer's Name
Date Purchased
n
Staple your receipt to this page in the event you need it
to prove date of purchase or for warranty issues.
READ THIS MANUAL
Inside you will find many helpful hints on how to use and
maintain your air conditioner properly. Just a little
preventive care on your part can save you a great deal
of time and money over the life of your air conditioner.
You'll find many answers to common problems in the
chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips first, you may not need to call for
service at all.
PRECAUTION
Contact the authorized service technician for repair or
maintenance of this unit.
• Contact the installer for installation of this unit.
The air conditioner is not intended for use by young
children or invalids without supervision.
Young children should be supervised to ensure that
they do not play with the air conditioner.
When the power cord is to be replaced, replacement
work shall be performed by authorized personnel only
using only genuine replacement parts.
Installation work must be performed in accordance
with the National Electric Code by qualified and
authorized personnel only.
Safety Precautions.................3
Prior to Operation ..................5
Operating Instructions...........6
Remote Controller ..............6
Remote Control Operation
...7
Maintenance and Service ....12
Indoor unit.........................12
Outdoor unit......................12
Operation Tips ..................13
Troubleshooting ...............14
Safety Precautions
Ownerʼs Manual 3
ENGLISH
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions
must be followed.
n Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classified by the following indications.
n Meanings of symbols used in this manual are as shown below.
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
Be sure not to do.
Be sure to follow the instruction.
WARNING
Plug in the power plug
properly.
• Otherwise, it will cause electric
shock or fire due to heat
generation or electric shock.
Do not operate or stop the
unit by inserting or pulling
out the power plug.
• It will cause electric shock or fire
due to heat generation.
Do not damage or use an
unspecified power cord.
It will cause electric shock or fire.
In the supply cord is damaged, it mut be
replaced by the manufacturer or its service
agent or a similarly quallfied person in
order to avoid a hazard. (Y Attachment)
Do not modify power cord
length or share the outlet
with other appliances.
• It will cause electric shock or fire
due to heat generation.
Do not operate with wet
hands or in damp
environment.
• It may cause electric shock.
Do not direct airflow at room
occupants only.
• This could damage your health.
Always perform grounding
work.
• No grounding may cause electric
shock.
Do not allow water to run
into electric parts.
• It may cause failure of machine or
electric shock.
Always install air leakage
breaker and a dedicated
switching board.
• No installation may cause fire and
electric shock accident.
Unplug the unit if strange
sounds, smell, or smoke
comes from it.
• It may cause fire and electric
shock accident.
Do not use the socket if it is
loose or damaged.
• It may cause fire and electric
shock.
Do not open the entrance
during operation.
• It may cause electric shock.
Safety Precautions
4 Room Air Conditioner
Ventilate before operating air conditioner
when gas goes out.
• It may cause explosion, fire and, burn.
Do not disassemble or modify products
randomly.
• It may cause failure and electric shock.
Use caution when unpacking and installing.
Sharp edges could cause injury.
If water enters the product, turn the power
switch of the main body of appliance off.
After taking the power-plug out from the
socket, contact with the service center.
If the liquid from the batteries gets onto your
skin or clothes, wash it well with clean water. Do
not use the remote if the batteries have leaked.
• The chemicals in batteries could cause burns or
other health hazards.
If you eat the liquid from the batteries, brush
your teeth and see doctor. Do not use the
remote if the batteries have leaked.
• The chemicals in batteries could cause burns or
other health hazards.
Never touch the metal parts of
the unit when removing the filter.
• They are sharp and may cause
injury.
Do not clean the air
conditioner with water.
Water may enter the unit and degrade the
insulation. It may cause an electric shock.
Ventilate well when used
together with a stove, etc.
• An oxygen shortage may occur.
CAUTION
When cleaning the unit, first
make sure the power and
breaker are turned off.
Since the fan rotates at high speed
during operation, it may cause injury.
Do not put a pet or house
plant where it will be
exposed to direct air flow.
• This could injure the pet or plant.
Do not use appliance for special purpose
such as animals or vegetables, precision
machine, or conservation of art articles.
• It may cause damage of animals
or vegetables or loss of property.
Stop operation and close the
window in storm or hurricane.
• Operation with windows opened
may cause wetting of indoor and
soaking of household furniture.
Hold the plug by the head of the
power plug when taking it out.
• It may cause electric shock and
damage.
Turn off the main power switch
when not using it for a long time.
• It may cause failure of product or
fire.
Do not place obstacles
around the absorption inlet
or instead of blowing-out
inlet.
• It may cause failure of appliance or
accident.
Ensure that an installation
console of the outdoor
appliance is not damaged due
to the use for a long time.
• If leaving appliance damaged,
there is concern of damage due to
the falling of product.
Always insert the filters
securely. Clean it once every
two weeks.
• Operation without filters may
cause failure.
Do not use strong detergent
such as wax or thinner but
use a soft cloth.
• Appearance may be deteriorated
due to change of product color or
scratching of its surface.
Do not place heavy object on the
power cord and take care so that
the cord should not be pressed.
• There is danger of fire or electric
shock.
Do not drink water drained
from air conditioner.
• It contains contaminants and will
make you sick.
Ownerʼs Manual 5
ENGLISH
Prior to operation
Prior to operation
1. Contact an installation specialist for installation.
2. Plug in the power plug properly.
3. Use a dedicated circuit.
4. Do not use an extension cord.
5. Do not start/stop operation by plugging/unplugging the power cord.
6. If the cord/plug is damaged, replace it with only an authorized replacement part.
1. Being exposed to direct airflow for an extended period of time could be hazardous to your health.
Do not expose occupants, pets, or plants to direct airflow for extended periods of time.
2. Due to the possibility of oxygen deficiency, ventilate the room when used together with stoves or
other heating devices.
3. Do not use this air conditioner for non-specified special purposes (e.g. preserving precision devices,
food, pets, plants, and art objects). Such usage could damage the items.
1. Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling
sharp metal edges.
2. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation,
leading to possible electric shock.
3. When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at
a very high speed during operation. There is a possibility of injury if the unitʼs power is accidentally
triggered on while cleaning inner parts of the unit.
For repair and maintenance, contact your authorized service dealer.
Preparing for operation
Usage
Cleaning and maintenance
Service
Symbols Used in this Manual
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that could cause harm to the
air conditioner.
This symbol indicates special notes.
NOTICE,
6 Room Air Conditioner
SignalG
receptor
Operation indication lamps
Operating Instructions
Remote Controller
Operating Instructions
Remove the battery cover by pulling it according to
the arrow direction.
Insert new batteries making sure that the (+) and (-)
of battery are installed correctly.
Reattach the cover by sliding it back into position.
Use 2 AAA(1.5volt) batteries. Do not use
rechargeable batteries.
NOTICE,
• The remote control may be stored mounted on a wall. • To operate the room air conditioner, aim the remote
control at the signal receptor.
Storage and Tips For Using the Remote Control
Signal Receptor
Receives the signals from the remote controller.
(Signal receiving sound:two short beeps or one long beep.)
Operation Indication Lamps
On/Off : Lights up during the system operation.
Defrost Mode : Lights up during Defrost Mode or *Hot Start operation.
(Heat pump model only)
: Lights up during outdoor unit operation.
(Cooling model only)
Outdoor Unit
Operation
OUT
DOOR
*Hot Start operation: Stops the indoor fan in Heating Operation to prevent cold air from blowing out from unit.
Ownerʼs Manual 7
ENGLISH
Operating Instructions
The remote control transmits the signals to the system.
G~GGd
GʼG~
G°°
GGd
4
1
2
3
Cooling Operation
Healthy Dehumidifacation Operation
Heating Operation
Cooling Operation
VyGGGGGGMGGGGGW
V–GGGMGGGGMGGGGGW
Healthy Dehumidifacation Operation
GʼG~
G°°
GGd
G~GGd
1
3
2
4
Remote Control Operation
OPERATION DISPLAY
Displays the operation conditions.
CHAOS SWING BUTTON
Used to stop or start louver movement and
set the desired up/down airflow direction.
OPERATION MODE SELECTION
BUTTON
Used to select the operation mode.
OFF TIMER BUTTON
Used to set the time of stopping operation.
START/STOP BUTTON
Operation starts when this button is
pressed, and stops when the button is
pressed again.
ROOM TEMPERATURE SETTING
BUTTONS
INDOOR FAN SPEED SELECTION
BUTTON
JET COOL
Used to start or stop the speed cooling.
(Speed cooling operates super high fan
speed in cooling mode.)
1
3
4
(1) Operation Mode
(2) Operation Procedure
1st
2nd
3rd
4th
Start/Stop Button
Operation Mode Selection Button
Room Temperature Setting Button
Indoor Fan Speed Selection Button
8 Room Air Conditioner
Operating Instructions
TIME
OFF
hr.
TEMP.
TEMP.
TIME
OFF
hr.
TIME
OFF
hr.
TEMP.
TIME
OFF
hr.
TEMP.
TIME
OFF
hr.
TEMP.
TIME
OFF
hr.
TEMP.
Cooling
HealthyG
Dehumidification
HeatingG
(Heat pump model only)
To raise the temperature
To lower the temperature
TEMP.
TIME
OFF
hr.
TIME
OFF
hr.
TEMP.
Cooling
HealthyG
Dehumidification
B
e
e
p
, B
e
e
p
B
e
e
p
, B
e
e
p
Press the Start/Stop Button.
Select Cooling Operation.
Press the Operation Mode Selection Button.
Each time the button is pressed, the operation mode is shifted in the arrow direction.
Set the temperature lower than the room temperature.
• The temperature can be set within a range of 18°C ~ 30°C
by 1°C .
Set the fan speed.
Select the fan speed in four steps-low, medium, high or CHAOS.
• Each time the button is pressed,
the fan speed mode is shifted.
The display shows high fan
speed.
Cooling Operation
1
2
3
4
Natural wind by the CHAOS logic
o For more fresh feeling than other fan speed, press the Indoor Fan Speed Selector and set to
CHAOS mode. In this mode, the wind blows like natural breeze by automatically changing fan
speed according to the CHAOS logic.
Healthy Dehumidification Operation Mode
This mode dehumidifies
without overcooling.
During Healthy Dehumidification Operation:
o If you select the dehumidification mode on the operation selection button, the airconditioner starts to run the
dehumidification function, automatically setting the room temp. and airflow volume to the best condition for
dehumidification based on the sensed current room temp.
In this case, however, the setting temp. is not displayed in the remote control and you are not able to control the
room temp. either.
o During the healthy dehumidification function, the airflow volume is automatically set according to the
optimization algorithm responding to the current room temp. status and makes the room condition healthy and
comfortable even in the high humidity season.
Ownerʼs Manual 9
ENGLISH
Operating Instructions
Beep, Beep
Beep, Beep
GʼG~
G°°
GGd
G~GGd
GʼG~
G°°
GGd
G~GGd
G~GGd
GʼG~
G°°
GGd
GʼG~
G°°
GGd
G~GGd
GʼG~
G°°
GGd
G~GGd
yGGGGGG
–GGGGGG
zGGGGGGGGGGGGGGG
Heating<
(Heat pump model only)
GGMGGGGGMGGGMGGGGGGGGGG
GGMGGGGGMGGGMGGGGGGGGGG
G~GGd
GʼG~
G°°
GGd
Press the OFF Time Button.
1. Press the OFF Time Button.
2. Check the OFF Time LED of the room air conditioner.
3. The Timer is programmed by 1 hour each
pressing the OFF Time button from 1 hour to 7 hours.
Timer control Setting
OFF TIMER CONTROL SETTING
Press the Start/Stop button.
The unit will respond with
a beep.
To select Heating Operation, press the Operation Mode
Selection button.
Each time the button is pressed, the operation mode is
shifted in the direction of the arrow.
Set the temperature higher than the room temperature.
The temperature can be set within a range of 16°C~30°C in
1°C increments.
Set the fan speed again with the door of the
remote control still closed. You can select
the fan speed in four steps–low, medium,
high, or CHAOS. Each time the button is
pressed, the fan speed mode is shifted.
Heating Operation(Heat pump model only)
1
2
3
4
10 Room Air Conditioner
Operating Instructions
or
or
or
GʼG~
G°°
GGd
G~GGd
o During the JET COOL function at any moment, the A/C starts to blow the cool air at
extremely high speed for 30 minutes setting the room temp. automatically to 18°C. It is
especially used to cool the room temp. in the shortest time in a hot summer.
In heat pump mode the JET COOL function is not available.
o In order to return to the normal cooling mode from the JET COOL mode, you just press
either the operation mode selection button, airflow volume selection or temp. setting button
or the JET COOL button again.
NOTICE,
Press the Start/Stop button.
The unit will respond with a beep.
Press the Jet Cool button to operate the
speed cooling mode and the unit will
operate in super high fan speed on cooling
mode for 30 minutes.
To cancel the Jet Cool mode, press the Jet Cool button
again or the fan speed button or the room temperature
setting button and the unit will operate in high fan speed on
cooling mode.
Jet Cool Operation
1
2
3
Ownerʼs Manual 11
ENGLISH
Power<
button
Open the frontG
panel upward
Operating Instructions
Vertical Airflow Direction Control
The up/down airflow (Vertical Airflow) can be adjusted
by using the remote control.
1. Press the Start/Stop button to start the unit.
2. Press Chaos Swing button and the louvers will swing
up and down. Press the Chaos Swing button again
to set the vertical louver at the desired airflow
direction.
o If you press the CHAOS swing button, the
horizontal airflow direction is changed
automatically based on the CHAOS algorithm to
distribute the air in the room evenly and at the
same time to make the human body feel most
comfortable, as if enjoying a natural breeze.
o Always use the remote control to adjust the
up/down airflow direction. Manually moving the
vertical airflow direction louver by hand, could
damage the air conditioner.
o When the unit is shut off, the up/down airflow
direction louver will close the air outlet vent of the
system.
NOTICE,
Horizontal Airflow Direction Control
• Adjust the horizontal airflow direction by manually moving the
horizontal airflow direction louver by hand.
Operation procedures when the remote control can't be used.
The operation will be started if the power button is pressed.
If you want to stop operation, re-press the button.
Forced Operation
Heat pump Model
Cooling
Model
Room Temp. 24°C 21°C Room Temp. < 24°C
Room Temp. < 21°C
Operating mode
Cooling Cooling
Healthy Dehumidification Heating
Indoor FAN Speed
High
High
High High
Setting Temperature
22°C
22°C
23°C
24°C
Test operation
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room
temperature and resets in 18 minutes.
During test operation, if remote controller signal is received, the unit operates as remote controller sets.
If you want to use this operation, open the front panel upward and Press the power button let it be pressed
for about 3 seconds.
If you want to stop the operation, re-press the button.
12 Room Air Conditioner
Maintenance and Service
G
a
s
o
l
i
n
e
P
o
w
d
e
r
Vertical louver
Horizontal louver
Air filtersG
(behind front panel)
Air outlet vent
Air inlet vent
(Side)
(Rear)
Air intakeG
vents
Air outletG
vents
(Side)
(Rear)
Drain Hose
Air intake vents
Air outlet vents
Piping
(Side)
(Rear)
Piping
Drain Hose
Air intakeG
vents
Air outletG
vents
Piping
Drain Hose
Maintenance and Service
Indoor Unit
Outdoor Unit
CAUTION: Before performing any maintenance, turn off the main power to the system.
Grille, Case, and Remote Control
o Turn the system off before cleaning. To clean, wipe
with a soft, dry cloth. Do not use bleach or
abrasives.
Supply power must be disconnected before cleaning
the indoor unit.
AIR FILTERS
The air filters behind the front grille should be checked
and cleaned once every 2 weeks or more often if
neccessary.
o
Never use any of the followings:
Water hotter than 40°C
Could cause deformation and/or
discoloration.
Volatile substances
Could damage the surfaces of the air
conditioner.
Lift the front access panel and pull the filter tab
slightly forward to remove the filter.
Clean the filter with a vacuum or warm, soapy
water.
• If dirt is conspicuous, wash with a solution
of detergent in lukewarm water.
• If hot water (40°C or more) is used, it may
be deformed.
After washing with water, dry well in the shade.
Re-install the air filter.
NOTICE,
The heat exchanger coils and panel vents of the outdoor unit
should be checked regularly. If clogged with dirt or soot, the
heat exchanger and panel vents may be professionally steam
cleaned.
Dirty or clogged coils will reduce the
operating efficiency of the system and cause
higher operating costs.
NOTICE,
Ownerʼs Manual 13
ENGLISH
Maintenance and Service
CAUTION
CAUTION
When the air conditioner is not going to be used for a long time.
Operation Tips
When air conditioner is not going to be
used for a long time.
When the air conditioner is to be used again.
Turn off the circuit breaker, and disconnect
the plug.
Remove the batteries from the remote
control.
Turn off the circuit breaker when the air conditioner
is not going to be used for a long time.
Dirt may collect and may cause a fire.
Clean the air filter and install it in the indoor
unit.
(Refer to page 12 for cleaning filters.)
Check that the air inlet and outlet of the
indoor/outdoor unit are not blocked.
Do not overcool the room.
This is not good for the health
and wastes electricity.
Make sure that the doors
and windows are shut tight.
Avoid opening doors and
windows as much as possible
to keep the cool air in the room.
Keep blinds or curtains
closed.
Do not let direct sunshine enter
the room when the air
conditioner is in operation.
Clean the air filter regularly.
Blockages in the air filter
reduce the airflow and lower
cooling and dehumidifying
effects. Clean at least once
every two weeks.
Keep the room temperature
uniform.
Adjust the vertical and
horizontal airflow direction to
ensure a uniform temperature
in the room.
Ventilate the room
occasionally.
Since windows are kept closed,
it is a good idea to open them
and ventilate the room now and
then.
14 Room Air Conditioner
Maintenance and Service
Troubleshooting
Check the following points before requesting repairs or service.... If the fault persists, please contact your dealer or
service center.
Case Explanation See page
The air conditioner does not
operate.
The room has a peculiar
odor.
It seems that condensation
is leaking from the air
conditioner.
Air conditioner does not
operate for about 3 minutes
when restarted.
Does not cool or heat
effectively.
The air conditioner
operation is noisy.
Remote control display is
faint, or no display at all.
Crack sound is heard.
• Have you made a mistake in timer operation?
• Has the fuse blown or has the circuit breaker
been tripped?
• Check that this is not a damp smell exuded by
the walls, carpet, furniture, or cloth items in the
room.
• Condensation occurs when the airflow from
the air conditioner cools the warm room air.
• This is the protector of the mechanism.
• Wait about three minutes and operation will
begin.
• Is the air filter dirty? See air filter cleaning
instructions.
• Has the temperature been set incorrectly?
• Are the indoor unit's air inlet or outlet vents
obstructed?
• For a noise that sounds like water flowing.
-This is the sound of freon flowing inside the
air conditioner unit.
• For a noise that sounds like the compressed
air releasing into atmosphere.
-This is the sound of the dehumidifying water
being processed inside the air conditioning
unit.
• Are the batteries depleted?
• Are the batteries inserted in the opposite (+)
and (-) directions?
• This sound is generated by the
expansion/constriction of the front panel, etc.
due to changes of temperature.
-
-
-
-
12
8, 9
-
-
6
-
www.lg.com
MODE D’EMPLOI
CLIMATISEUR
Veuillez lire attentivement ce manuel avant d’utiliser votre
appareil, et le conserver pour toute consultation ultérieure.
FRANÇAIS
2 Climatiseur
Manuel de l'utilisateur Climatiseur
TABLE DES MATIERES
POUR VOS ARCHIVES
Ecrivez le modèle et le numéro de série ici:
Modèle Nº
Nº de série
Vous les trouverez sur une étiquette dans la partie
latérale de chaque unité.
Nom du distributeur
Date d'achat
n
Agrafez votre reçu à cette page au cas où vous en
auriez besoin pour prouver la date d'achat ou pour vous
prévaloir de la garantie.
LISSEZ CE MANUEL
Vous trouverez dedans plusieurs conseils utiles sur la manière
d'utiliser et d'entretenir correctement votre climatiseur. Seul un petit
soin préventif de votre part peut vous permettre une grande
économie de temps et d'argent pendant la durée de vie de votre
climatiseur. Vous trouverez plusieurs réponses aux problèmes
communs dans la charte de conseils de dépannage. Si vous lisez
d'abord notre charte de Conseils de dépannage, il est possible que
vous n'ayez aucun besoin d'appeler le service technique.
PRECAUTION
• Contactez un technicien agréé pour la réparation ou maintenance de cette
unité.
• Contactez l'installateur pour l'installation de cette unité.
• Le climatiseur n'est pas destiné à l'usage de petits enfants ou dʼ
handicapés sans surveillance.
• Vos enfants doivent être surveillés afin de vous assurer qu'ils ne jouent
pas avec le climatiseur.
• Lorsque le cordon d'alimentation doit être remplacé, ce travail de
remplacement ne doit être réalisé que par du personnel autorisé à l'aide de
pièces de rechange d'origine.
• Le travail d'installation doit être réalisé conformément au Normes
Electrique National, seulement par du personnel qualifié et agréé.
Précautions de sécurité........3
Avant la mise en service.......5
Consignes d'utilisation.........6
Commande à distance.......6
Fonctionnement de la
commande à distance .......7
Entretien et réparations ......12
Unité interne.....................12
Unité externe ....................12
Suggestions pour
l'utilisation ........................13
Résolution des
problèmes ........................14
Précautions de sécurité
Manuel de l'utilisateur 3
FRANÇAIS
Précautions de sécurité
Pour éviter de réels préjudices ou pour éviter que l'utilisateur ou d'autres personnes ne se blessent, vous devez respecter
les instructions suivantes.
n En ne tenant pas compte de ces instructions, vous prenez le risque de faire une mauvaise manipulation qui entraînera des
préjudices ou des dommages dont la gravité est indiquée ci-dessous.
n
Les éléments à respecter sont classés par les symboles suivants.
DANGER
ATTENTION
Ce symbole indique le danger de mort ou de graves blessures.
Ce symbole indique le risque de préjudices ou de dégâts concernant
uniquement les biens.
Ne faites jamais cela
Faites toujours ceci
DANGER
Branchez correctement la prise.
• Sinon, cela provoquera une
électrocution ou un incendie du à un
dégagement de chaleur ou à une
décharge électrique.
Ne mettez pas en marche/nʼarrêtez
pas lʼappareil en débranchant le
cordon dʼalimentation.
• Cela provoquera une électrocution ou
un incendie du à un dégagement de
chaleur.
Nʼutilisez pas un cordon
dʼalimentation abîmé ou non-
conforme.
• Cela provoquera une électrocution ou
un incendie.
• Si le cordon dʼalimentation est abîmé,
vous devez le remplacer par un cordon
spécial ou un montage disponible chez
votre fabricant ou chez ses revendeurs.
Ne modifiez pas la longueur de
fil et ne branchez pas dʼautres
appareils sur la même prise.
• Cela provoquera une électrocution ou
un incendie du à un dégagement de
chaleur.
Ne touchez pas lʼappareil si
vous avez les mains mouillées
et ne le faites pas fonctionner
dans un endroit humide.
• Risque dʼélectrocution.
Ne dirigez pas le débit dʼair
seulement en direction des
personnes présentes dans la
pièce.
• Ceci pourrait nuire à votre santé.
Mettez toujours à la masse.
• Aucune mise à la terre ne peut causer
le choc électrique.
Lʼeau ne doit pas sʼinfiltrer dans
les parties électriques.
• Il peut causer la panne de la machine
ou le choc électrique.
Installez toujours un joint
dʼétanchéité empêchant les
fuites dʼair et un tableau de
commande efficace.
• Aucune installation ne peut causer
l'accident du feu et de choc électrique.
Prière de débrancher la prise si un
son puissant/une odeur forte apparaît
ou si de la fumée sort de lʼappareil.
• Risques dʼincendies et dʼaccidents de
type électrocutions.
Nʼutilisez jamais de prise
abîmée ou desserrée.
• Risques dʼincendies ou
dʼélectrocutions.
Nʼouvrez pas lʼentrée pendant
le fonctionnement.
• Risques dʼélectrocutions.
Précautions de sécurité
4 Climatiseur
Afin de permettre la ventilation, ouvrez la fenêtre avant
de faire fonctionner le système de climatisation ou la
télécommande lorsque le gaz sʼéchappe.
• Risque dʼexplosions, incendies ou brûlures.
Ne démontez pas et ne modifiez pas lʼappareil au
hasard.
• Risque de pannes ou dʼ électrocutions.
Si vous retirez un élément de lʼappareil, veillez à ce
quʼaucun enfant ne lʼavale, par mégarde. Placez
lʼélément dans un endroit que les enfants ne
peuvent pas atteindre.
Quand de lʼeau etc. entre dans les éléments,
éteignez lʼinterrupteur principal de lʼappareil.
Après avoir retiré la fiche de la prise, contactez le
service après-vente.
En cas de contact du liquide des piles avec votre
peau ou vos vêtements, lavez-les à l'eau. N'utilisez
pas la télécommande si les piles ont coulé.
• Les produits chimiques à lʼintérieur des piles peuvent
causer des brûlures ou d'autres blessures.
Si vous ingurgitez le liquide de la pile, lavezvous
les dents et consultez votre dentiste. Ne pas utiliser
la télécommande si les piles ont fuit.
• Les produits chimiques àlʼintérieur des piles
pourraient vous causer des brûlures ou d'autres
ennuis de santé.
Ne touchez jamais les parties en métal parts
de lʼappareil lorsque vous retirez le filtre.
• Risques de préjudices.
Ne nettoyez pas la climatisation
à lʼeau.
Lʼeau peut sʼinfiltrer dans lʼappareil et dégrader
lʼisolation. Cela pourrait provoquer une électrocution.
Aérez correctement lorsquʼun four
(etc.…) fonctionne en même temps.
• Un manque dʼoxygène peut subvenir.
ATTENTION
Lorsque vous nettoyez lʼappareil,
vérifiez dʼabord que lʼalimentation
et le disjoncteur sont éteints.
• Puisque, pendant le fonctionnement,
le ventilateur tourne à une vitesse très
élevée, il y a un risque de préjudices.
Ne mettez pas dʼanimaux
domestiques ni de plantes
devant le débit dʼair direct.
• Cela pourrait abîmer les plantes ou
blesser les animaux domestiques.
Nʼutilisez pas lʼappareils à des fins spécifiques,
tels que les animaux, les végétaux, les machines
outils ou la conservation des œuvres dʼart.
• Cela pourrait blesser les animaux ou
les végétaux ou entraîner des pertes
matérielles.
Arrêtez le fonctionnement de
lʼappareil et fermez la fenêtre en
cas dʼorage ou de typhon.
Si vous faites fonctionner lʼappareil avec les fenêtres
ouvertes, vous risquez dʼaugmenter lʼhumidité de la
pièce et cette humidité peut abîmer vos meubles.
Débranchez lʼappareil en tirant
sur la prise et non pas sur e fil.
• Risques dʼélectrocutions et de
préjudices
Tirez lʼinterrupteur dʼalimentation
principal si vous nʼutilisez pas
lʼappareil pendant un certain temps.
• Le produit risque de tomber en panne
ou cela peut provoquer un incendie.
Ne placez pas dʼobstacles
autour de lʼouïe dʼabsorption et
lʼouïe de sortie.
• Lʼappareil risque de tomber en panne
ou cela peut provoquer un accident.
Vérifiez que la console
dʼinstallation de lʼappareil externe
nʼest pas abîmée par lʼusure.
Si vous laissez lʼappareil abîmé en lʼétat, en se
détériorant, le produit risque de provoquer des dégâts.
Utilisez toujours des filtres
installés correctement et
nettoyez-les une fois par semaine.
• Lʼappareil risque de tomber en panne si
vous le faites fonctionner sans filtres.
Nʼutilisez pas de détergents puissants
tel que de la cire ou un solvant mais
utilisez un chiffon doux.
• Lʼapparence peut se dégrader à cause
dʼune modification de la couleur du
produit ou dʼune surface rayée.
Ne placez pas dʼobjets lourds sur
le cordon dʼalimentation et veillez
à ne pas appuyer sur le cordon.
• Danger dʼincendie ou dʼélectrocution.
Ne purgez pas lʼeau du système
de climatisation.
• Risques de troubles gastriques.
Manuel de l'utilisateur 5
FRANÇAIS
Avant la mise en service
Avant l'utilisation
1. Contactez un spécialiste en installations pour l'installation.
2. Branchez correctement la prise d'alimentation.
3. Utilisez un circuit dédié.
4. N'utilisez pas de rallonges.
5. Ne mettez pas en marche ou éteignez cet appareil en branchant/débranchant le cordon d'alimentation.
6. Si le cordon ou la fiche est endommagé, remplacez-le seulement par une pièce de rechange autorisée.
1. S'exposer directement sous le flux d'air pour une longue période de temps pourrait entraîner des risques
pour la santé.
N'exposez pas directement les occupants, les animaux ou les plantes au flux d'air pour de longues
périodes de temps.
2. Afin d'éviter de possibles déficiences d'oxygène, aérez la pièce lorsque vous utilisez cette unité
simultanément avec des poêles ou d'autres dispositifs de chauffage.
3. N'utilisez pas ce climatiseur pour des objectifs spéciaux non spécifiés dans ce manuel (p.ex. pour
préserver des dispositifs de précision, des aliments, des animaux, des plantes ou des objets d'art). Un tel
usage pourrait endommager les composants de l'unité.
1. Ne touchez pas aux composants métalliques de l'unité lors de l'enlèvement du filtre. Vous pourriez vous
blesser en manipulant des bords métalliques affilés.
2. N'utilisez pas de l'eau pour nettoyer l'intérieur du climatiseur. Le contact avec de l'eau détruit l'isolement,
entraînant de possibles chocs électriques.
3. Lors du nettoyage de l'unité, assurez-vous d'abord que
l'interrupteur et le disjoncteur sont sur la position Arrêt (OFF). Le ventilateur tourne à une vitesse très
forte pendant que l'unité est en marche. Vous pourriez vous blesser si l'unité est accidentellement mise
en marche alors que vous nettoyez les parties intérieures de l'unité-
Pour réparation et maintenance, contactez le service technique agrée de votre revendeur.
Préparation pour la mise en service
Utilisation
Nettoyage et entretien
Service technique
Symboles utilisés dans ce manuel
Ce symbole vous avertit sur un risque d'électrocution.
Ce symbole vous avertir sur les risques d'endommager le
climatiseur.
Ce symbole indique des notes spéciales.
NOTICEI
6 Climatiseur
Récepteurw
signal
Voyants lumineux de w
fonctionnementw
w
Mode d'emploi
Commande à distance
Consignes d'utilisation
Enlevez le couvercle des piles en le tirant dans la
direction indiquée par la flèche.
Mettez les nouvelles piles en vous assurant que les
pôles (+) et (-) des piles soient dans la direction
correcte.
Refermez le couvercle en le faisant glisser dans sa
position.
Utilisez des piles AAA (1.5 Volt). N'utilisez
pas de piles rechargeables.
NOTICEI
• La télécommande peut être conservée montée sur un
mur.
• Pour mettre en marche le conditionneur d'air de la
pièce, pointez la télécommande sur le récepteur du
signal.
Conservation et conseils pour l'utilisation de la télécommande
Récepteur signal
Reçoit le signal de la télécommande.
(Le son de réception du signal est de deux bip courts et un long).
Voyants lumineux de fonctionnement
Allumé : Sʼallume pendant le fonctionnement du système.
Mode Dégel :
Il s'allume en mode dégivrage ou lors du *HOT START
OPERATION. (uniquement pour modèle pompe à chaleur)
: S'allume alors que l'unité extérieure est en marche
(Modèle refroidissement uniquement)
Fonctionnement de
l'unité extérieure
OUT
DOOR
*Hot Start Operation: Arrêtez le ventilateur interne lorsque le climatiseur est en mode
de fonctionnement chauffage afin d'éviter que l'unité ne souffle de
l'air refroidi.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31

LG S246KH Le manuel du propriétaire

Catégorie
Climatiseurs split-system
Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues