West Marine 8646275 Le manuel du propriétaire

Taper
Le manuel du propriétaire
Features
120 Amp SI* Automatic Charging Relay (ACR)
*Starting Isolation
•Automaticallycombinesbatteriesduringcharging,
isolatesbatteriesduringenginecrankingand
whennotcharging
•Allowstemporaryisolationofhouseloadsfrom
enginecircuitduringenginecrankingtoprotect
sensitiveelectronics
•Supportshigh-outputalternatorsupto120Amps.
•Ignitionprotected-safeforinstallationaboard
gasolinepoweredboats
•Undervoltagelockout-willnotclosewhenthe
lowerbatteryisbelow10.8Vat12Voperationor
21.6Vat24Voperation
•BuiltinLEDlightindicateswhenbatteriesare
combined
•Meetsexternalignitionprotectionrequirements.
•WaterproofratedIP67temporaryimmersionfor
30minutes
•Designedfor12or24voltsystems.
•Senseschargesourceoneitherbatterybank
e-Series, Dual Circuit Plus™ Battery Switch
•Switchestwobatterybankssimultaneously
withonesimpleON/OFFswitchwhilemaintaining
batterybankisolation,minimizingtheriskofadead
startbattery
•TheCOMBINEBATTERIESfunctionoffersthe
abilitytocombinetwobatterybanksintheeventof
alowbattery
•Meetsexternalignitionprotectionrequirements.
MarineElectricalProd
ucts
ADD A BATTERY Dual Circuit System
PN 7650
ADD A BATTERY Dual Circuit System ADD A BATTERY Dual Circuit System
PN 7650
ADD A BATTERY Dual Circuit System
PN 7650
Specications
120 Amp SI ACR 12 Volt 24 Volt
ContinuousRating 120Amps 120Amps
MaximumCableSize 1/0AWG 1/0AWG
TerminalStudSize 3/8”16(M10) 3/8”16(M10)
MaximumTorque 140in-lbs 140in-lbs
RelayContactPosition
-Combine (30sec.) 13.6Volts 27.2Volts
  (2min.) 13.0Volts 26.0Volts
-OpenLow (10sec.) 12.35Volts 24.7Volts
  (30sec.) 12.75Volts 25.5Volts
-OpenHigh 16.0Volts 30.0Volts
Dual Circuit Plus™ Battery Switch
ContinuousRating 350Amps
IntermittentRating 525Amps
InrushRating 1,500Amps
SystemVoltage upto48Volts
CableSize 4/0AWG
TerminalStudSize 3/8”16(M10)
MaximumTorque 140in-lbs
Regulatory: CE markedforignitionprotection,
meetsISO8846ignitionprotection,andSAEJ1171
externalignitionprotectionrequirements,RatedIP67.
Particularités
120 Amp SI* Automatic Charging Relay (ACR)
*Isolementaudémarrage
•Ilcombineautomatiquementlesbatteriespendantla
charge,lesisolependantledémarragedumoteuret
pendantqu’ellesnechargentpas.
•Permetl’isolementtemporairedescharges
domestiquesducircuitdumoteurpendantson
démarragepourprotégerlescomposants
électroniquessensibles.
•Tolèreleshautsrendementsdesalternateursjusqu’à
120A.
•Ilsatisfaitlesexigencesdeprotectiond’allumage
externe.
•Ilnefermerapasquandlatensiondelabatterie
lamoinschargéeestinférieureà10,8V
(applicationde12V)ou21,6V(applicationde24V).
•DiodeLEDincorporéepourindiquerquelesbatteries
sontcombinées.
•ÉtanchéitéduniveauIP67—immersiontemporairede
30minutes.
•Conçupourlessystèmesde12ou24V.
•Détectelasourcedecharged’unerangéede
batteries.
e-Series, Dual Circuit Plus™ Battery Switch
•Commutedeuxgroupesdebatteriessimultanément,
aumoyend’unsimplecommutateurMARCHE/ARRET,
toutenmaintenantl’isolementdugroupedebatteries.
•Combinedeuxgroupesdebatteriesencasde
batterieàfaibledémarrage.
•Ilsatisfaitlesexigencesdeprotectiond’allumage
externe.
Fiche technique
120 Amp SI ACR 12 V 24 V
Toléranceencontinue 120A 120A
Tailledecâblemaximale 1/0AWG 1/0AWG
Tailledecossemâle 3/8po16(M10)3/8po16(M10)
Coupledeserrage 140lb/po² 140lb/po²
maximal
Positiondescontactsdurelais
-Combinée (30s) 13,6V 27,2V
(2mn) 13,0V 26,0V
-Ouvertbas(10s) 12,35V 24,7V
(30s) 12,75V 25,5V
-Ouvertélevé 16,0V 30,0V
Dual Circuit Plus™ Battery Switch
Toléranceencontinue 350A
Toléranceintermittente 525A
Toléranceparcoup 1,500A
Voltage 48V
Tailledecâblemaximale 4/0AWG
Tailledecossemâle 3/8”16(M10)
Coupledeserragemaxima 140lb-po²
Réglementation:MarquéCEpourlaprotection
d’allumage,respectelanorme8846del’Organisation
denormalisationinternationaleliéeàlaprotection
d’allumage,ainsiquelesexigencesdeprotection
d’allumageexterneJ1171delaSAE,qualiéeIP67.
Características
120 Amp SI* Automatic Charging Relay (ACR)
*AislamientodeArrancada
•Combinaautomáticamentelasbateríasdurante
lacarga,aíslalasbateríasdurantelaarrancadadel
motorycuandonoestánsiendocargadas.
•Permiteelaislamientotemporaldecargasdela
casadelcircuitodelmotordurantelaarrancadadel
motorconelndeprotegerloscircuitossensitivos.
•Soportaalternadoresdesalidaaltahastade
120Amps.
•Satisfacelosrequisitosdeproteccióndeignición
externa.
•Nosecierracuandolabateríabajaestápordebajo
de10,8voltios(operacióna12V)ó21,6voltios
(operacióna24V).
•LEDintegradoindicaquelasbateríasestán
combinadas.
•ClasicaciónimpermeableIP67—inmersión
temporalde30minutos.
•Diseñadoparasistemasde12ó24voltios.
•Detectalafuentedecargaencualquieradelos
bancosdebaterías.
e-Series, Dual Circuit Plus™ Battery Switch
•Commutasimultaneamenteduegruppidibatterie
conunsempliceinterruttoreON/OFF,mantenendo
isolatoilgruppodibatterie.
•Abbinaiduegruppidibatterieincasodidifcoltàdi
avviamentodellabatteria.
•Satisfacelosrequisitosdeproteccióndeignición
externa.
Especicaciones
120 Amp SI ACR 12 Voltios 24 Voltios
Clasicacióncontinua 120Amps. 120Amps.
Máximotamañodecable 1/0AWG 1/0AWG
Tamañodeterminalde 3/8”16(M10)3/8”16(M10)
espárrago
Torsiónmáxima 140lbs./pul. 140lbs./pul.
Posicióndecontactodelrelé
-Combinado (30seg.) 13,6Voltios 27,2Voltios
(2min.) 13,0Voltios 26,0Voltios
-Abiertobajo (10seg.) 12,35Voltios24,7Voltios
(30seg.) 12,75Voltios 25,5Voltios
-Abiertoalto 16,0Voltios 30,0Voltios
Dual Circuit Plus™ Battery Switch
Clasicacióncontinua 350Amps.
Clasicaciónintermitente 525Amps.
Clasicacióndecorriente 1,500Amps.
deentrada
Voltios 48Voltios
Máximotamañodecable 4/0AWG
Tamañodeterminalde 3/8”16(M10)
espárrago
MaximumTorque 140lbs./pul.
Regulatorio:MarcadoCEparaProtecciónde
Ignición,cumpleconlaregulación8846deISO
paraproteccióndeigniciónyconlosrequisitos
deprotecciondeigniciónexternaJ1171deSAE,
ClasicaciónIP67.
Caratteristiche
120 Amp SI* Automatic Charging Relay (ACR)
*Isolamentodurantelafasediavviamento
•Combinaautomaticamentelebatterieduranteil
caricamento,isolalebatteriedurantel’avviamento
delmotoreeinassenzadicarico.
•Assicural’isolamentotemporaneodeicarichidella
casadalcircuitodelmotoredurantel’avviamento
delmotorestesso,perproteggereleparti
elettronichesensibili
•Supportaalternatoriadaltaproduzionenoa
120Amp.
•Conformeairequisitidiprotezionedell’accensione
esterna.
•Nonsichiudequandoillivellodellabatteriaèinferiore
a10,8Volt(funzionamentoa12V)oda21,6Volt
(funzionamentoa24V).
•Spiaincorporata,indicachelebatteriesonocombinate.
•GradodiimpermeabilitàIP67—immersione
temporaneaper30minuti.
•Concepitoperimpiantia12o24volt.
•Rilevalafontedicaricasuogniseriedibatterie.
e-Series, Dual Circuit Plus™ Battery Switch
•Conectadosbloquesdebateríassimultáneamente,
conunúnicointerruptorde
CONEXIÓN/DESCONEXIÓN,manteniendoalmismo
tiempoelaislamientodelosbloquesdebaterías.
•Combinadosbloquesdebateríasenelcasodeuna
bateríadearranquebajo.
•Conformeairequisitidiprotezionedell’accensione
esterna.
Speciche
120 Amp SI ACR 12 Volt 24 Volt
Potenzanominalecontinua120Amp 120Amp
Dimensionemassimadelcavo1/0AWG 1/0AWG
Dimensionedelperno m10(3/8”16)m10(3/8”16)
terminale
Coppiadiserraggiomassima140in-lbs 140in-lbs
Posizionedicontattodelrelé
-Combina (30sec.) 13,6Volt 27,2Volt
(2min.) 13Volt 26Volt
-Apertobasso(10sec.) 12,35Volt 24,7Volt
(30sec.) 12,75Volt 25,5Volt
-Apertoalto 16Volt 30Volt
Dual Circuit Plus™ Battery Switch
Potenzanominalecontinua 350Amp
Potenzanominale 525Amp
intermittente
Potenzanominaledipunta 1,500Amp
Voltage upto48Volt
Dimensionemassimadelcavo4/0AWG
Dimensionedelpernom 3/8”16(M10)
terminale
Coppiadiserraggiomassima140in-lbs
Normativa:MarchiCEperlaprotezione
dell’accensione,conformeairequisitidella
protezionedell’accensioneISO8846edella
protezionedell’accensioneesternadiSAEJ1171,
NominalediesercizioIP67.
Produitsélectriquesmarins Productoseléctricosmarinos Prodottielettricimarini
990310020Rev.004
Blue Sea Systems Inc. Phone (360) 738-8230
425 Sequoia Drive Fax (360) 734-4195
Bellingham, WA 98226 USA E-mail [email protected]
www.bluesea.com
PN 7650
page1of4
Electrical Connections
• Theillustratedwiringdiagramrepresentsacommoninstallationandisnotmeanttobeaguidefor
wiringaspecicvessel.
Caution: Disconnectrstthepositivethenthenegativebatteryconnectionsbeforebeginning
theinstallation.Reconnectaftertheinstallationiscomplete.
UsethewiresizingchartbelowtoselecttheappropriatewiresizestopreventoverheatingtheACR.
Wire sizing chart
Charging Amps Minimum Wire Size*
60 #6
80 #4
100 #2
120 #1/0
Dual Circuit Plus™ Battery Switch Installation:
•Mountthebatteryswitchinaneasilyaccesiblelocationclosetothebatteries.
•Attachone4/0AWGcableperterminaltomeetratings.
•Terminalsmustbeattachedundernutandlockwasher.Torqueto140in-lb(15.82N-m)
Operation:
• TurnallappliancesoffbeforeturningthebatteryswitchtoOFF.
• DonotswitchtoOFFwhiletheengineisrunning.
• Open.CloseCycling-Ifyouelectricalsystemisconguredwithachargingsourcethatcannotsupply
thefullloadcurrentbeingdrawnfromthereceivingbattery,anopen-closecyclingprocesscanoccur.
Ifthiscyclingcontinues,thesecondbatterybankcouldeventuallydischargeeventhoughacharge
sourceispresent.
• The120ASIACRisnotintendedtocarrystartingcurrents.UsethebatteryswitchCOMBINE
BATTERIESpositiontocombinebatterybanksforemergencystarting.
*Largerwiresizesmayberequiredtominimizevoltagedropinlongwireruns.
Formoreinformationpleasevisitwww.bluesea.com
120A SI ACR Installation:
•Tominimizecorrosiontowireandterminals,mountinadryandprotectedlocation.Avoidlocations
directlyabovebatterybanks.
•Tosensechargingsourcesoneitherbatterybank,connectonebatterybankpositivetostud
terminalA.ConnecttheotherbatterybankpositivetostudterminalB.
ConnectthequickconnectterminalmarkedGND(ground)totheDCsystemgroundthrough
atentofteenampin-linefusetopreventfaultcurrentsfromowinginthiswire.
ConnectawirefromthequickconnectlockoutterminalmarkedSI(startingisolation)totheterminal
orwirerunningfromthestartkeyswitchtothestartersolenoid.Makethisconnectionthroughan
in-linefuseof1to10Amps.Thisconnectioncanbemadeatthestartkeyswitchoratthestarter
solenoid,butmustbetothelinethatispositiveonlywhencranking.Connectiontoalinethatis
positivewhiletheengineisnormallyrunningwillpreventthechargingrelayfromworkingproperly.
•ToconnectaremoteLEDindicator,connecttheredwireoftheLEDtoapositivesource.
ConnecttheyellowwireoftheLEDtothequickconnectterminalmarkedLED.
Connexions électriques
• Lacongurationdecâblagereprésenteuneinstallationcommuneetn’estpasdestinéeàservirde
guidepourlecâblaged’unvaisseauparticulier.
Précaution: Débrancheztoutd’abordlesconnectionspositives,puisnégativesdesbatteriesavantde
commencerl’installation.Raccordez-lesaprèsavoirterminél’installation.
Utilisezletableaudetaillesdelci-dessouspoursélectionnerlestaillesdelappropriéesdansle
butd’éviterlasurchauffeduACR.
Installation du Dual Circuit Plus™ Battery Switch:
•Montezl’interrupteurdebatteriessurunemplacementfacilementaccessibleprèsdesbatteries.
•Raccordezuncâblede4/0AWGparcossepourrespecterlestolérances.
•Lescossesdescâblesdebatteriesdoiventêtrexéespardesrondellesdesûretéetécrous.
Serrez-lesàuncouplede15,82N.m(140lb/po²)
Fonctionnement:
•Éteigneztouslesappareilsavantdemettrel’interrupteurdebatteriessurlapositiond’ARRÊT.
•Nechangezpaslapositiondel’interrupteurpendantquelemoteurtourne.
•Cycled’ouverture/fermeture–Sivotresystèmeélectriquecomporteunesourcedechargene
pouvantpasfournirlatotalitéducourantétantdemandéeparlabatterielerecevant,l’interrupteur
peuts’ouvrir/sefermerplusieursfois.Sicecyclecontinuait,laseconderangéedebatteriespourrait
éventuellementsedéchargerbienqu’unesourcedechargesoitprésente.
•Le120ASIACRn’estpasdestinéàtransporterdescourantsdedémarrage.Utilisezlapositionde
BATTERIESCOMBINÉESdel’interrupteurdebatteriesandecombinerdesrangéesdebatteries
pourledémarraged’urgence.
Installation du 120A SI ACR:
•Danslebutdeminimiserlacorrosiondeslsetcosses,montez-ledansunendroitsecetàl’abri.
Évitezlesemplacementsdirectementau-dessusdesrangéesdebatteries.
•Pourdétecterlessourcesdechargesurunedesrangéesdebatteries,branchezlepositifd’une
rangéedebatteriesàlacossemâleA.Connectezlepositifdel’autrerangéedebatteriesàla
cossemâleB.
•RaccordezlacosseàraccordrapidemarquéeGND(masse)àlamassedusystèmeàcourant
continuaumoyend’unfusibleenlignededixàquinzeampèresdanslebutd’empêcherles
courantsdedéfautdecirculerdanscel.
•Branchezunlentrelaborned’arrêtàraccordrapidemarquéeSI(isolationdedémarrage)etla
borneoulelquirelielecontacteurdedémarrageausolénoïdededémarreur.Effectuezce
branchementparl’intermédiaired’unfusibleenlignede1à10A.Cebranchementpeutêtre
effectuéauniveauducontacteurdedémarrageoudusolénoïdededémarreur,maisdoitsefaire
versunelignequiestpositiveuniquementpendantledémarrage.Unbranchementàuneligne
quiestpositivependantquelemoteurtournenormalementempêchelefonctionnementcorrect
durelaisdecharge.
•PourconnecterunediodeLEDàdistance,raccordezlelrougedeladiodeàunesourcepositive.
Guarantee
AnyBlueSeaSystemsproductwithwhichacustomerisnotsatisedmaybereturnedforarefundor
replacementatanytime.
Installation Instructions Instructions d’installation
*Destaillesdelpluslargespeuventêtrerequises
pourminimiserlachutedetensionsurleslongsls.
Pourplusderenseignements,veuillezvisiterlesite
Internetwww.bluesea.com
Tableau de tailles de l
Intensitédecharge(A) Tailleminimaledel*
50 10mm
2
70 16mm
2
90 25mm
2
110 35mm
2
120 50mm
2
Garantie
Siunclientn’estpassatisfaitd’unproduitdeBlueSeaSystems,ilpeutlerenvoyerpourselefaire
rembourserouremplaceràtoutmoment.
ConnectawirefromthequickconnectlockoutterminalmarkedSI(startingisolation)totheterminalorwirerunningfromthestartkey
switchtothestartersolenoid.Makethisconnectionthroughanin-linefuseof1to10Amps.Thisconnectioncanbemadeatthestart
keyswitchoratthestartersolenoid,butmustbetothelinethatispositiveonlywhencranking.Connectiontoalinethatispositive
whiletheengineisnormallyrunningwillpreventthechargingrelayfromworkingproperly.
page2of4
120 Amp SI Automatic Charging Relay Dimensions
e-Series, Dual Circuit PlusBattery Switch Dimensions
e-Series, Dual Circuit PlusBattery Switch Mounting Options
120 Amp SI Automatic Charging Relay Side and Bottom Knockouts
990310020Rev.004
page4of4
Fuse Fusible Fusible Fusibile
RemoteLED LEDàdistance LEDremoto LEDremoto
StartKey Clédecontact Llavedearranque Chiavediavviamento
SI
Starting Isolation Isolementaudémarrage AislamientodeArrancada
Isolamentodurantela
fasediavviamento
GND
Ground Masse Tierra Massa
Optional Optionnel Opcional Opzionale
GND
SI LED
Surface Mount Rear Panel Mount
0.750" MAX
19.05mm
1.200"
30.48mm
1.590"
40.39mm
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

West Marine 8646275 Le manuel du propriétaire

Taper
Le manuel du propriétaire