NuTone NW830SS Manuel utilisateur

Catégorie
Hottes
Taper
Manuel utilisateur
Serial number:
99046155 rev. A
WWW.NUTONE.COM
CHIMNEY
RANGE HOOD
NW830SS
INSTALLATION, USE
AND CARE MANUAL
2
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
qualified personnel in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guidelines and safety standards such as
those published by the National Fire Protection Association
(NFPA) and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE) and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any solid-state speed control device.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.
10. To provide protection against electric shock, connect to properly
grounded outlet only.
11. When applicable local regulations comprise more restrictive
installation and/or certification requirements, the aforementioned
requirements prevail on those of this document and the installer
agrees to conform to these at his own expense.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee,
Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan, filters or in exhaust ducts.
d) Use proper pan size. Always use cookware appropriate for the
size of the surface element.
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced
impeller, keep drywall spray, construction dust, etc. off power unit.
4. Your hood motor has a thermal overload which will automatically
shut off the motor if it becomes overheated. The motor will
restart when it cools down. If the motor continues to shut off
and restart, have the hood serviced.
5. The minimum hood distance above cooktop must not be less
than 26". For best capture of cooking impurities, the bottom
of the hood should be at a maximum of 30" above cooking
surface. For a gas range, the bottom of the hood MUST NOT
BE LESS than 30" above cooktop.
6. Two installers are recommended because of the large size and
weight of this unit.
7. To reduce the risk of fire and to properly exhaust air, be sure to
duct air outside — Do not exhaust air into spaces within walls
or ceiling or into attics, crawl space or garage.
8. Because of the high exhausting capacity of this unit, you
should make sure enough air is entering the house to replace
exhausted air by opening a window close to or in the kitchen.
9. To reduce the risk of fire and electrical shock, the NuTone NW8
Series models should only be installed with their own built-in
blower.
10. When used in recirculation mode, to reduce the risk of fire and
shock, use only conversion kit model RK58.
11. Please read specification label on product for further information
and requirements.
WARNING
!
CAUTION
WARNING
!
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE
THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY,
EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels —
This could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You own a Class ABC extinguisher and you know how to
operate it.
B. The fire is small and contained in the area where it started.
C. The fire department has been called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
Register your range hood online at www.nutone.com
INTENDED FOR DOMESTIC COOKING ONLY
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGE 10.
READ AND SAVE THESE INSTRUCTIONS
! !
3
1. P REPARE INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2. SELECT INSTALLATION TYPE . . . . . . . . . . . . . . . . . . . . . . . . . 3
3. WIRING INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4. I
NSTALL HOOD MOUNTING BRACKET . . . . . . . . . . . . . . . . . . . . 4
5. INSTALL UPPER FLUE MOUNTING BRACKET. . . . . . . . . . . . . . . . 5
6. REMOVE GREASE FILTERS . . . . . . . . . . . . . . . . . . . . . . . . . . 5
7. I NSTALL 6” ROUND ADAPTER/DAMPER. . . . . . . . . . . . . . . . . . . 5
8. INSTALL THE HOOD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
9. D
UCT CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
10. PREPARE THE DECORATIVE FLUE. . . . . . . . . . . . . . . . . . . . . . 8
11. INSTALL THE DECORATIVE FLUE. . . . . . . . . . . . . . . . . . . . . 8-9
12. R
EINSTALL GREASE FILTERS. . . . . . . . . . . . . . . . . . . . . . . . . 9
13. OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
14. CARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
15. REPLACEMENT PART S . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
16. WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
TABLE OF CONTENTS
1. PREPARE INSTALLATION
NOTE: Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the retailer.
Make sure that the following items are included:
- Hood
- Decorative flue assembly (lower and upper flues)
- Hood mounting bracket
- Lower flue mounting bracket
- Upper flue mounting bracket
- 2 Aluminum grease filters
- 6” Round adapter/damper
- Installation instructions
- Parts bag: 10 no. 8 x 5/16” mounting screws,
7 no. 8 x 1½” mounting screws,
7 drywall anchors, 2 washers
Parts sold separately:
- Ducts, elbows, wall and roof caps.
- Optional flue extension for 10-ft. ceilings model FXN58SS.
- Non-duct kit model RK58, mandatory for non-ducted installation.
NOTE: During installation, protect countertop and/or cooktop.
HR0202A
DECORATIVE
FLUE
LOWER FLUE
MOUNTING
BRACKET
HOOD
MOUNTING
BRACKET
UPPER FLUE
MOUNTING
BRACKET
6” ROUND
ADAPTER/DAMPER
2. SELECT INSTALLATION TYPE
2.1 NON-DUCTED INSTALLATION
The RK58 non-duct kit is required for a non-ducted installation.
2.2 DUCTED INSTALLATION
Plan where and how the ductwork will be installed.
A straight, short duct run will allow the hood to perform most efficiently. Long duct
runs, elbows and transitions will reduce the performance of the hood. Use as few
of them as possible. Larger ducting may be required for longer duct runs.
Install wall or roof cap. Connect 6” round metal ductwork to cap and work back
towards the hood location. Use 2” metal foil duct tape to seal the joints.
2.3 ALL INSTALLATIONS
The minimum hood distance above cooktop is 26” (30” over a gas range).
A maximum of 30” above cooktop is recommended for best capture of cooking
impurities.
Distances over 30” are at the installer and users discretion providing that ceiling
height and decorative flue length allow it.
6” ROUND
DUCT
ROOF CAP
6” ROUND
ELBOW
WALL
CAP
HOOD
DECORATIVE
FLUE
HH0251A
26” MINIMUM ABOVE
COOKING
SURFACE
(30” FOR GAS RANGE)
WARNING
!
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
4
WARNING
!
Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. This
range hood must be properly grounded. Turn off electrical power at service entrance before wiring.
3. WIRING INSTALLATION
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an
escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must
be plugged into an outlet that is properly installed and grounded.
Set the electrical power supply within the space covered by the decorative flue.
Position the outlet offset so that the power cord will not interfere with the round duct. Place
the outlet at a maximum distance of 33
7
/16" from where the cord exits from the hood (see
illustration at right). Make sure this does not interfere with a mounting bracket fastening
area or with the decorative flue (where the flue touches the wall).
WARNING
!
Improper grounding can result in a risk of electric shock. Consult a qualified electrician if the grounding instructions
are not completely understood, or if doubt exists as to whether the appliance is properly grounded. Do not use an
extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the appliance.
HE0299
33
7
16"
MAX.
4. INSTALL HOOD MOUNTING BRACKET
HD1026A
FRAMING BEHIND DRYWALL
WALL STUDS
36 ¾” = BOTTOM OF HOOD 26” ABOVE COOKTOP
40 ¾” = BOTTOM OF HOOD 30” ABOVE COOKTOP
WARNING
!
When cutting or drilling into wall, do not damage electrical wiring and other hidden utilities.
When building framework, always follow all applicable construction codes and standards.
Construct wood wall framing that is even with the surface of wall studs.
Wood wall framing must be at least 1/2” thick and 3” high. Fasten wood wall
framing to wall studs for a solid installation.
Make sure that the height of the framing will allow the mounting bracket to be
secured to the framing within the dimensions shown.
After wall surface is finished, carefully center and level the hood
mounting bracket over installation location. Secure it to wall framing using
3 no. 8 x 1½” screws.
Using a level, draw a vertical line up to the ceiling starting from the mounting
bracket center.
5
5. INSTALL UPPER FLUE MOUNTING BRACKET
Center the upper flue mounting bracket with the center line previously
drawn in step 4 and place it flush with the ceiling. Make sure that the slots
of the upper flue bracket point down. Use the upper flue mounting bracket
as a template to mark the position of its screws.
Drill both screw holes using a 5/16” drill bit. Insert the included drywall
anchors into the drilled holes (one per hole).
Secure the upper flue bracket to the wall using 2 no. 8 x 1½” mounting
screws. Make sure that the bracket is tight against the wall.
C
L
HD1027
CENTER OF INSTALLATION
CEILING
UPPER FLUE MOUNTING
BRACKET SLOTS
MOUNTING BRACKET
FLUSH WITH CEILING
6. REMOVE GREASE FILTERS
Lay the back side of the hood flat on a table. Use a piece of cardboard to
avoid damaging the table or the hood.
To remove the grease filters, pull down on the metal latch tab and tilt each
filter downward. Set filters aside.
HD1028
7. INSTALL 6” ROUND ADAPTER/DAMPER
Mount the 6” round adapter/damper (included) using 4 no. 8 x 5/16” screws (included).
Seal the adapter/damper to the hood using metal foil duct tape.
NON-DUCTED INSTALLATION: Remove both damper flaps.
HJ0156
DAMPER
FLAPS
8. INSTALL THE HOOD
CAUTION
DO NOT REMOVE the protective plastic film covering the decorative flue (upper & lower) yet.
1. Align the hood and center it above the hood mounting bracket. Gently lower the hood until it securely engages the bracket.
2. Level the hood.
3. With the hood hanging in place, drill through both holes located in the
inside lower back of hood using a 5/16” drill bit (see illustration at right).
4. Insert the included drywall anchors into the drilled holes (one for each hole).
5. Verify that the hood is still centered and leveled.
6. Secure the hood to the wall using 2 no. 8 x 1½” screws and 2 washers.
Tighten both screws completely.
WARNING
!
BE CAREFUL when installing the decorative flue and hood, they may have sharp edges.
SIDE
VIEW
HOLES LOCATION (Ø 5/16” TYP.)
M
OTOR/ BLOWER
ASSEMBLY
ADAPTER/DAMPER
HD1029A
6
9. DUCT CONNECTION
VERTICALLY DUCTED INSTALLATION:
Plug hood power cord into the outlet. Slide a 6” round metal duct section over the
adapter/damper on the hood. Use metal foil duct tape to seal the joint.
HJ0157
HORIZONTALLY DUCTED INSTALLATION:
Plug hood power cord into the outlet. Measure and install 6” round metal ductwork to wall
cap and 90° elbow over duct collar over the adapter/damper on the hood. Use metal foil
duct tape to seal the joints.
HJ0159
14¼
MAX.
LOWER FLUE
MOUNTING
BRACKET
HD1033A
NOTE: To make sure there will be adequate clearance between top of hood and lower
flue mounting bracket for ductwork, elbow must be located below the lower flue
mounting bracket.
7
NON-DUCTED INSTALLATION:
Plug hood power cord into the outlet.
Measure the length of 6” round flexible duct (included in the non-duct kit) required from
the top of the hood to the ceiling. Slide the 6” round flexible metal duct over the adapter
(whitout damper flaps) on the hood; attach with one included tie-wrap. Use metal foil duct
tape to seal the joint.
HJ0158
9. DUCT CONNECTION (CONTINUED)
Using 4 ST4 x 8 provided screws, assemble the 6” round adapter to the plenum.
F
RONT
HA0138
Attach the aluminum flexible duct to the non-duct plenum collar. Make sure non-duct plenum “FRONT” is
facing front of hood. Secure with tie wrap and seal with metal foil duct tape.
FRONT
HJ0160
8
10. PREPARE THE DECORATIVE FLUE
LOUVERS
HO0285
LOWER FLUE
REAR NOTCH
Peel off both corners at the top of the upper flue.
NOTE: For non-ducted installation only, remove enough plastic film to clear the louvers.
Position the lower flue rear notches down.
Gently slide upper flue inside lower flue, louvers end up.
Both lower and upper flues are included with the hood, but for a 10-foot ceiling, discard the provided
upper flue and use the optional flue extension, part no. FXN58SS (sold separately).
Remove the upper flue from inside the lower flue. Remove protective plastic film covering the
lower flue only. Install the lower flue bracket to its flue using 2 no. 8 x 5/16” mounting screws,
ensure that the slots point up.
HO0114
LOWER FLUE MOUNTING BRACKET
BACK VIEW
SLOTS UP
LOWER
FLUE
11. INSTALL THE DECORATIVE FLUE
Carefully slide in place decorative flue base (notches end first) in the groove on the top of the
hood. Slightly slide up the upper flue to avoid any damage while installing the lower flue to the
top of the hood using 2 no. 8 x 5/16” screws through the lower flue side slots.
HO0286
9
11. INSTALL THE DECORATIVE FLUE (CONTINUED)
NON-DUCTED INSTALLATION:
Pull the upper flue up and attach the non-duct plenum with collar to the upper flue using 4 ST4 x 8
provided screws.
HJ0161
ALL INSTALLATIONS:
Slide up the upper flue until it is aligned with its mounting bracket. The bracket must be
inside the flue. Secure the upper flue to its bracket using 2 no. 8 x 5/16” mounting screws.
NOTE: Duct (or non-duct plenum) not shown in illustration to ease understanding.
Remove protective plastic film covering the upper flue and the hood.
HO0287
UPPER FLUE MOUNTING BRACKET
FRONT VIEW
UPPER
FLUE
DUCTED INSTALLATION:
Attach the 6” round duct section to the rest of the ducting. Use metal foil duct tape to seal the joint.
12. REINSTALL GREASE FILTERS
ALL INSTALLATIONS:
To reinstall the grease filters, align rear filter tabs with slots in the hood.
Pull down the metal latch tab, push each filter into position and release.
Make sure filters are securely engaged after installation.
HD1030
NON-DUCTED INSTALLATION:
Attach two non-duct recirculation filters to sides of blower by aligning key lock slot and rotating
until filters lock into place.
HA0137
10
13. OPERATION
Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clear the
air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.
NOTE: When pressed, the chosen push button beeps and its indicator lights up blue.
HC0085
BLOWER ON / SPEED INCREASE PUSH BUTTON (DOUBLE FUNCTION PUSH BUTTON):
Press one time on this push button to activate the blower at low speed, a second time for medium speed and a third time for high
speed.
NOTE: When blower is turned on, 100% of power level is activated during 1 to 2 seconds acting as a “kick-start”. It will then operate
at the desired setting.
BLOWER OFF / SPEED DECREASE PUSH BUTTON (DOUBLE FUNCTION PUSH BUTTON):
Press on this push button to lower the blower speed. If need be, press until the blower stops.
DELAY SETTING PUSH BUTTON:
To set delay, press this push button when blower and/or lights are in use. Blower and/or lights will continue to operate for 10 minutes
and then will stop automatically (the delay setting push button indicator will blink during the 10 minutes to indicate that the delay has
been activated). To cancel delay function, press on this push button again, the blower and/or lights will continue to operate and won’t
stop until Blower OFF / Speed decrease push button and/or Lighting push button is pressed.
LIGHTING PUSH BUTTON:
Press once on this push button to turn the lights on. Press once more to turn the lights off.
14. CARE
Grease Filters
Grease filters should be cleaned frequently. Use a warm dishwashing detergent solution to clean the filters.
Clean all-metal filters using a non-phosphate detergent. Discoloration of the filters may occur if using phosphate detergents, or as a result
of local water conditions - but this will not affect filter performance. This discoloration is not covered by the warranty. To minimize or prevent
discoloration, hand wash filters using a mild detergent.
Non-ducted Filters
Change the non-duct recirculation filters every 6 months. Rotate the filters to remove them from the blower and replace; purchase
S97018030 or ROUNDFILTER.
Hood Cleaning
Stainless Steel Cleaning:
Avoid when choosing a detergent:
- Any cleaners that contain bleach will attack stainless steel.
- Any products containing: chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.
- Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive and should never be
used close to a range.
Do:
Regularly wash with clean cloth or rag soaked with warm water
and mild soap or liquid dish detergent.
Always clean in the direction of original polish lines.
Always rinse well with clear water (2 or 3 times) after cleaning.
Wipe dry completely.
You may also use a specialized household stainless steel
cleaner.
Don’t:
Use any steel or stainless steel wool or any other scrapers to
remove stubborn dirt.
Use any harsh or abrasive cleansers.
Allow dirt to accumulate.
Let plaster dust or any other construction residues reach the
hood. During construction/renovation, cover the hood to make
sure no dust sticks to stainless steel surface.
11
15. REPLACEMENT PARTS
1
2
3
4
5
6
7
8
9
HL0388
REPLACEMENT PARTS AND REPAIRS
In order to ensure your unit remains in good
working condition, you must use Broan-
NuTone LLC genuine replacement parts only.
Broan-NuTone LLC genuine replacement parts
are specially designed for each unit and are
manufactured to comply with all the applicable
certification standards and maintain a high
standard of safety. Any third party replacement
part used may cause serious damage and
drastically reduce the performance level of
your unit, which will result in premature failing.
Broan-NuTone LLC recommends to contact a
certified service depot for all replacement parts
and repairs.
KEY
NO.
PART NO.DESCRIPTION QUANTITY
1 S99526972 DECORATIVE UPPER AND LOWER FLUES 1
2 S99526983 ADAPTER/DAMPER 1
3 S99528925 CONTROL ASS'Y 1
4 S99528926 LED
DRIVER 1
5 S99528361 M
OTOR AND BLOWER ASSEMBLY 1
6 S99528927 LED
LIGHTS (SET OF 2) 1
7 S97018027 ALUMINUM GREASE FILTERS (SET OF 2) 1
8 S99527662 C
APACITOR 1
9 S99528928 PCB 1
10 S99528929 BRACKET KIT (SET OF 3) 1
* S99526993
P
ARTS BAG INCLUDING: 10 NO. 8 X 5/16" MOUNTING SCREWS,
7 NO. 8 X 1½" MOUNTING SCREWS, 7 DRYWALL ANCHORS, 2 WASHERS.
1
* NOT SHOWN.
12
Limited Warranty
Warranty Period and Exclusions: Broan-NuTone LLC (the “Company”) warrants to the original consumer purchaser of its product (“you”) that
the product (the “Product”) will be free from material defects in the Product or its workmanship for a period of one (1) year from the date of original
purchase (or such longer period as may be required by applicable law). The limited warranty period for any replacement parts provided by the
Company and for any Products repaired or replaced under this limited warranty shall be the remainder of the original warranty period (or such
longer period as may be required by applicable law).
This warranty does not cover fluorescent lamp starters, tubes, halogen and incandescent bulbs, fuses, filters, ducts, roof caps, wall caps and
other accessories for ducting that may be purchased separately and installed with the Product. This warranty also does not cover (a) normal
maintenance and service, (b) normal wear and tear, (c) any Products or parts which have been subject to misuse, abuse, abnormal usage,
negligence, accident, improper or insufficient maintenance, storage or repair (other than repair by the Company), (d) damage caused by faulty
installation, or installation or use contrary to recommendations or instructions, (e) any Product that has been moved from its original point of
installation, (f) damage caused by environmental or natural elements, (g) damage in transit, (h) natural wear of finish, (i) Products in commercial
or nonresidential use, or (j) damage caused by fire, flood or other act of God or (k) Products with altered, defaced or removed serial numbers. This
warranty covers only Products sold to original consumers in the United States by the Company or its U.S. distributors authorized by the Company.
This warranty supersedes all prior warranties and, subject to applicable law, is not transferable from the original consumer purchaser.
No Other Warranties: This Limited Warranty contains the Company’s sole obligation and your sole remedy for defective products. The foregoing
warranties are exclusive and in lieu of any other warranties and conditions, express or implied. THE COMPANY DISCLAIMS AND EXCLUDES
ALL OTHER EXPRESS WARRANTIES AND CONDITIONS, AND DISCLAIMS AND EXCLUDES ALL WARRANTIES AND CONDITIONS
IMPLIED BY LAW, INCLUDING WITHOUT LIMITATION THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
To the extent that applicable law prohibits the exclusion of implied warranties or conditions, the duration of any applicable implied warranty or
condition is limited to the period specified for the express warranty above. Some jurisdictions do not allow limitations on how long an implied
warranty lasts, so the above limitation may not apply to you. Any oral or written description of the Product is for the sole purpose of identifying it
and shall not be construed as an express warranty.
Whenever possible, each provision of this Limited Warranty shall be interpreted in such manner as to be effective and valid under applicable law,
but if any provision is held to be prohibited or invalid, such provision shall be ineffective only to the extent of such prohibition or invalidity, without
invalidating the remainder of such provision or the other remaining provisions of the Limited Warranty.
Remedy: During the applicable limited warranty period, the Company will, at its option, provide replacement parts for, or repair or replace, without
charge, any Product or part thereof, to the extent the Company finds it to be covered by and in breach of this limited warranty under normal use
and service. The Company will ship the repaired or replaced Product or replacement parts to you at no charge. You are responsible for all costs
for removal, reinstallation and shipping, insurance or other freight charges incurred in the shipment of the Product or part to the Company. If you
must send the Product or part to the Company, as instructed by the Company, you must properly pack the Product or part—the Company is not
responsible for damage in transit. The Company reserves the right to utilize reconditioned, refurbished, repaired or remanufactured Products
or parts in the warranty repair or replacement process. Such Products and parts will be comparable in function and performance to an original
Product or part and warranted for the remainder of the original warranty period (or such longer period as may be required by applicable law).
Company reserves the right, in its sole discretion, to refund the money actually paid by you for the Product in lieu of repair or replacement. If
the Product or component is no longer available, replacement may be made with a similar product of equal or greater value, at Company’s sole
discretion. This is your sole and exclusive remedy for breach of this limited warranty.
Exclusion of Damages: THE COMPANY’S OBLIGATION TO PROVIDE REPLACEMENT PARTS, OR REPAIR, REPLACE OR REFUND, AT
THE COMPANY’S OPTION, SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY AND THE COMPANY’S
SOLE AND EXCLUSIVE OBLIGATION. THE COMPANY SHALL NOT BE LIABLE FOR INCIDENTAL, INDIRECT, CONSEQUENTIAL OR
SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE PRODUCT, ITS USE OR PERFORMANCE. Incidental damages
include but are not limited to such damages as loss of time and loss of use. Consequential damages include but are not limited to the cost of
repairing or replacing other property which was damaged if the Product does not work properly.
THE COMPANY SHALL NOT BE LIABLE TO YOU, OR TO ANYONE CLAIMING UNDER YOU, FOR ANY OTHER OBLIGATIONS OR
LIABILITIES, INCLUDING, BUT NOT LIMITED TO, OBLIGATIONS OR LIABILITIES ARISING OUT OF BREACH OF CONTRACT OR
WARRANTY, NEGLIGENCE OR OTHER TORT OR ANY THEORY OF STRICT LIABILITY, WITH RESPECT TO THE PRODUCT OR THE
COMPANY’S ACTS OR OMISSIONS OR OTHERWISE.
Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not
apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from jurisdiction to jurisdiction. The
disclaimers, exclusions, and limitations of liability under this warranty will not apply to the extent prohibited by applicable law.
This warranty covers only replacement or repair of defective Products or parts thereof at the Company’s main facility and does not include the cost
of field service travel and living expenses.
Any assistance the Company provides to or procures for you outside the terms, limitations or exclusions of this limited warranty will not constitute
a waiver of such terms, limitations or exclusions, nor will such assistance extend or revive the warranty.
The Company will not reimburse you for any expenses incurred by you in repairing or replacing any defective Product, except for those incurred
with the Company’s prior written permission.
How to Obtain Warranty Service: To qualify for warranty service, you must (a) notify the Company at the address or telephone number stated
below within seven (7) days of discovering the covered defect, (b) give the model number and part identification and (c) describe the nature of any
defect in the Product or part. At the time of requesting warranty service, you must present evidence of the original purchase date. If you cannot
provide a copy of the original written limited warranty, then the terms of the Company’s most current written limited warranty for your particular
product will control. The most current limited written warranties for the Company’s products can be found at www.nutone.com.
Broan-NuTone LLC 926 West State Street, Hartford, WI 53027 www.nutone.com 1-888-336-3948
16. WARRANTY
Numéro de série :
99046155 rév. A
WWW.NUTONE.COM
HOTTE
CHEMINÉE
NW830SS
MANUEL D’INSTALLATION,
D’UTILISATION ET D’ENTRETIEN
2
Enregistrez votre hotte en ligne à www.nutone.com
CONÇUE POUR USAGE RÉSIDENTIEL SEULEMENT
INSTALLATEUR : LAISSER CE GUIDE AU PROPRIÉTAIRE.
PROPRIÉTAIRE : DIRECTIVES D’UTILISATION ET D’ENTRETIEN EN PAGE 10.
LIRE ET CONSERVER CES DIRECTIVES
! !
AFIN DE RÉDUIRE LES RISQUES D’INCENDIE,
D’ÉLECTROCUTION OU DE BLESSURES CORPORELLES,
SUIVEZ LES DIRECTIVES SUIVANTES :
1. N’utilisez cet appareil que de la façon prévue par le manufacturier.
Si vous avez des questions, contactez le manufacturier à
l’adresse ou au numéro de téléphone indiqués dans la garantie.
2. Avant de réparer ou de nettoyer l’appareil, couper l’alimentation
électrique en verrouillant le panneau de distribution afin d’éviter
sa remise en marche accidentelle. Si le panneau de distribution
ne peut être verrouillé, y fixer un avertissement en évidence,
telle qu’une étiquette de couleur vive.
3. Les travaux d’installation et de raccordement électrique doivent
être effectués par une personne qualifiée, conformément
aux codes et aux standards de construction, incluant ceux
concernant la protection contre les incendies.
4. Une quantité d’air adéquate est requise afin d’assurer une bonne
combustion et l’évacuation des gaz par la cheminée dans le cas des
équipements alimentés au gaz afin de prévenir les retours de
cheminée. Conformez-vous aux instructions et aux standards de
sécurité des manufacturiers d’équipement de chauffage, tel qu’ils
sont publiés par la National Fire Protection Association (NFPA)
et l’American Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE) ainsi que les responsables des codes locaux.
5. Veillez à ne pas endommager le câblage électrique ou d’autres
équipements non apparents lors de la découpe ou du perçage
du mur ou du plafond.
6. Les ventilateurs avec conduits doivent toujours évacuer l’air à
l’extérieur.
7. Ne pas utiliser cet appareil avec une commande de vitesse à
semi-conducteur.
8. Afin de réduire les risques d’incendie, n’utilisez que des
conduits de métal.
9. Cet appareil doit être mis à la terre.
10. Afin de prévenir les risques d’électrocution, la fiche doit être branchée
dans une prise de courant correctement installée et mise à la terre.
11. Lorsqu’une réglementation est en vigueur et qu’elle comporte
des exigences d’installation et/ou de certification plus
restrictives, lesdites exigences prévalent sur celles de ce
document et l’installateur entend s’y conformer à ses frais.
AFIN DE RÉDUIRE LES RISQUES DE FEU DE
CUISINIÈRE :
a) Ne jamais laisser les appareils de cuisson sans surveillance
lorsqu’ils sont réglés à feu vif. Les débordements engendrent de
la fumée et des déversements graisseux pouvant s’enflammer.
Chauffez l’huile lentement, à feu doux ou moyen.
b) Mettez toujours la hotte en marche lorsque vous cuisinez à feu
vif ou que vous cuisinez des mets flambés (par ex. : crêpes
Suzette, cerises jubilé, steaks au poivre flambés).
c) Nettoyez régulièrement la roue du ventilateur. Ne laissez pas la graisse
s’accumuler sur le ventilateur, les filtres ou les conduits d’évacuation.
d) Utilisez le bon format de casserole. Ser vez-vous toujours de casseroles
et d’ustensiles appropriés à la dimension de la surface chauffante.
1. Pour une utilisation à l’intérieur seulement.
2. Pour usage domestique seulement. Ne pas utiliser pour évacuer
des vapeurs ou des matières dangereuses ou explosives.
3. Afin d’éviter tout dommage au moteur et de débalancer ou de
rendre bruyante la roue du moteur, garder votre appareil à l’abri
des poussières de gypse et de construction/rénovation, etc.
4. Le moteur de votre hotte possède une protection thermique qui
éteindra automatiquement le moteur s’il devient surchauffé. Le
moteur redémarrera automatiquement une fois refroidi. Si le
moteur continue à arrêter et à redémarrer, faites-le vérifier.
5. La distance minimale de la hotte au-dessus de la surface de cuisson
NE DOIT PAS être inférieure à 26 po. Pour une meilleure
évacuation des odeurs de cuisson, la distance maximale
recommandée au-dessus de la surface de cuisson est de 30 po.
Pour une cuisinière au gaz, le bas de votre hotte NE DOIT PAS
ÊTRE INFÉRIEUR à 30 po au-dessus de la surface de cuisson.
6. Deux installateurs sont recommandés lors de l’installation vu la
grande dimension et le poids de cet appareil.
7. Afin de réduire les r isques d’incendie, assurez-vous d’évacuer l’air à
l’extérieur. Ne pas évacuer l’air dans des espaces restreints comme
l’intérieur des murs ou plafond ou dans le grenier, faux plafond ou garage.
8. En raison de la grande capacité d’évacuation de cette hotte, il
est recommandé d’ouvrir une fenêtre dans ou près de la cuisine
afin de remplacer l’air évacué.
9. Afin de réduire les risques d’incendie et d’électrocution, les
hottes NuTone de série NW8 ne doivent être installées qu'avec
leur ventilateur intérieur intégré.
10. Afin de réduire les risques de feu ou d'électrocution, si la
hotte est utilisée en mode recirculation, utiliser uniquement
l'ensemble de recirculation modèle RK58.
11. Veuillez consulter l’autocollant apposé à l’intérieur de la hotte
pour plus d’information ou d'autres exigences.
AVERTISSEMENT
!
ATTENTION
AFIN D’ÉVITER TOUT RISQUE DE BLESSURES LORS
D’UN FEU DE CUISINIÈRE, SUIVEZ CES DIRECTIVES* :
1. Étouffez les flammes avec un couvercle hermétique, une tôle à
biscuits ou un plateau métallique et ensuite, éteindre le brûleur.
PRENEZ SOIN D’ÉVITER les brûlures. SI LES FLAMMES NE
S’ÉTEIGNENT PAS IMMÉDIATEMENT, ÉVACUEZ LES LIEUX
ET APPELEZ LES POMPIERS.
2. NE PRENEZ JAMAIS UNE CASSEROLE EN FLAMMES
DANS VOS MAINS. Vous pourriez vous brûler.
3. N’UTILISEZ PAS D’EAU, incluant un linge à vaisselle ou une
serviette mouillée, cela pourrait occasionner une violente
explosion de vapeur.
4. N’utilisez un extincteur QUE DANS LE CAS OÙ :
A. Vous savez qu’il s’agit d’un extincteur de classe ABC et que
vous en connaissez le fonctionnement.
B. Le feu est petit et limité à l’endroit où il a débuté.
C. Les pompiers ont été avisés.
D. Vous pouvez combattre le feu en ayant accès à une sortie
de secours.
*Tirées du Kitchen Fire Safety Tips publié par la NFPA.
AVERTISSEMENT
!
3
1. P RÉPARER L'INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . 3
2. CHOISIR LE TYPE D'INSTALLATION . . . . . . . . . . . . . . . . . . . . . 3
3. INSTALLATION ÉLECTRIQUE. . . . . . . . . . . . . . . . . . . . . . . . . . 4
4. I
NSTALLER LE SUPPORT DE MONTAGE DE LA HOTTE. . . . . . . . . . 4
5. INSTALLER LE SUPPORT DE MONTAGE
DU CONDUIT DÉCORATIF SUPÉRIEUR. . . . . . . . . . . . . . . . . . . . 5
6. RETIRER LES FILTRES À GRAISSES . . . . . . . . . . . . . . . . . . . . 5
7. I NSTALLER L'ADAPTATEUR/VOLET DE 6 PO ROND. . . . . . . . . . . . 5
8. INSTALLER LA HOTTE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
9. R
ACCORDER LE CONDUIT . . . . . . . . . . . . . . . . . . . . . . . . 6-7
10. PRÉPARER LE CONDUIT DÉCORATIF . . . . . . . . . . . . . . . . . . . . 8
11. INSTALLER LE CONDUIT DÉCORATIF . . . . . . . . . . . . . . . . . . 8-9
12. R
EMETTRE EN PLACE LES FILTRES À GRAISSES . . . . . . . . . . . . 9
13. FONCTIONNEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
14. ENTRETIEN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
15. PIÈCES DE RECHANGE . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
16. GARANTIE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
TABLE DES MATIÈRES
1. PRÉPARER L'INSTALLATION
NOTE : Avant de commencer l’installation, vérifier le contenu de la boîte. Si des pièces sont manquantes ou endommagées, contacter
le détaillant.
S’assurer que les articles suivants sont inclus :
- Hotte
- Ensemble conduit décoratif (inférieur et supérieur)
- Support de montage de la hotte
- Support de montage du conduit décoratif inférieur
- Support de montage du conduit décoratif supérieur
- 2 filtres à graisses en aluminium
- Adaptateur/volet de 6 po rond
- Manuel d'installation
- Sac de pièces : 10 vis de montage n° 8 x 5/16 po,
7 vis de montage n° 8 x 1½ po,
7 douilles à expansion, 2 rondelles
Pièces vendues séparément :
- Conduits, coudes, capuchons de mur ou de toit.
- Rallonge de conduit décoratif pour plafonds de 10 pi.,
modèle n° FXN58SS.
- Ensemble de recirculation modèle RK58, obligatoire pour une installation en recirculation.
NOTE : Lors de l'installation, protéger la surface de cuisson ou le comptoir de cuisine.
HR0202F
CONDUIT
DÉCORATIF
SUPPORT DE MONTAGE
DU
CONDUIT
DÉCORATIF
SUPÉRIEUR
SUPPORT DE MONTAGE
DE
LA HOTTE
SUPPORT DE MONTAGE
DU
CONDUIT
DÉCORATIF
SUPÉRIEUR
ADA PTATEUR/VOLET
DE
6 PO ROND
2. CHOISIR LE TYPE D'INSTALLATION
2.1 INSTALLATION EN RECIRCULATION
L'ensemble de recirculation RK58 est requis pour ce type d'installation.
2.2 INSTALLATION AVEC CONDUITS
Déterminer à quel endroit et de quelle façon les conduits seront installés.
Un conduit droit et court permettra à la hotte de fonctionner plus efficacement.
Un conduit long avec des coudes et des transitions réduira la performance de
la hotte. En utiliser le moins possible. Pour une grande distance, un conduit
d’évacuation d’air au diamètre plus grand peut être requis.
Installer un capuchon de toit ou de mur. Relier le conduit de 6 po rond en métal
au capuchon, puis acheminer le conduit jusqu’à l’emplacement de la hotte.
Sceller les joints avec du ruban adhésif de métal de 2 po de largeur.
2.3 TOUTES LES INSTALLATIONS
La distance minimale entre le bas de la hotte et la surface de cuisson est
de 26 po (30 po au-dessus d'une cuisinière à gaz). Un maximum de 30 po
au-dessus de la surface de cuisson est recommandé pour une meilleure
évacuation des odeurs de cuisson.
Les distances au-delà de 30 po sont à la discrétion de l’installateur et de
l’utilisateur, si la hauteur du plafond et du conduit décoratif le permettent.
CONDUIT ROND
DE
6 PO
CAPUCHON DE TOIT
COUDE
6 PO ROND
CAPUCHON
DE
MUR
HOTTE
CONDUIT
DÉCORATIF
HH0251F
MINIMUM 26 PO AU-DESSUS
DU
PLAN DE CUISSON
(30 PO POUR CUISINIÈRE À GAZ)
AVERTISSEMENT
!
Lors de l’installation, de l’entretien ou du nettoyage de l’appareil, il est recommandé de porter des lunettes et des
gants de sécurité.
4
3. INSTALLATION ÉLECTRIQUE
HE0299
33
7
16 PO
MAX.
4. INSTALLER LE SUPPORT DE MONTAGE DE LA HOTTE
AVERTISSEMENT
!
Le raccordement électrique doit être effectué par du personnel qualifié en respectant les normes et règlements en
vigueur. Cet appareil doit être relié à une mise à la terre. Avant d’effectuer le branchement, coupez l’alimentation
électrique depuis le tableau de distribution principal.
INSTRUCTIONS POUR MISE À LA TERRE
Cet appareil doit être relié à une mise à la terre. En cas de court-circuit électrique, la mise à la terre réduit le risque d’électrocution en
fournissant un câble d’évacuation du courant. Cet appareil est muni d’un cordon équipé d’un câble de mise à la terre avec fiche de mise
à la terre. La fiche doit être branchée dans une prise de courant correctement installée et mise à la terre.
Installer l’alimentation électrique dans l’espace qui sera couvert par le conduit décoratif.
Placer la prise de façon désaxée et à une distance maximale de 33
7
/16 po de l’endroit
où le fil sort de la hotte (voir l’illustration ci-contre). S’assurer qu’elle n’interfère pas avec
l’emplacement de fixation d’un support de montage ou avec le conduit décoratif (à l’endroit
où il touche le mur).
AVERTISSEMENT
!
Un mise à la terre inadéquate peut entraîner un risque d’électrocution. Consultez un électricien si les instructions
de mise à la terre ne sont pas tout à fait compréhensibles ou si un doute persiste quant à savoir si l’appareil
est correctement relié à la terre. Ne pas utiliser de rallonge électrique. Si le cordon d’alimentation est trop court,
demandez à un électricien d’installer une prise de courant près de l’appareil.
Construire un cadre mural en bois encastré entre les montants et au même
niveau que ceux-ci.
Le cadre mural doit avoir au moins 1/2 po d’épaisseur et 3 po de hauteur. Pour
une installation solide, s’assurer de fixer le cadre mural aux montants.
S’assurer que la hauteur du cadre permettra au support de montage d’y
être bien fixé en respectant les dimensions indiquées (voir l’illustration
ci-contre).
Après la finition du mur, centrer le support au-dessus de l’emplacement de
l’installation et mettre de niveau. Fixer le support de montage au cadre mural à
l’aide de 3 vis n° 8 x 1½ po.
À l’aide d’un niveau, tracer une ligne verticale jusqu’au plafond à partir du
centre du support de montage de la hotte.
36¾
PO = BAS DE LA HOTTE 26 PO AU-DESSUS DU PLAN DE CUISSON
42¾ PO = BAS DE LA HOTTE 30 PO AU-DESSUS DU PLAN DE CUISSON
AVERTISSEMENT
!
Veillez à ne pas endommager le câblage électrique ou d’autres équipements non apparents lors de la découpe
ou du perçage du mur ou du plafond.
Lors de la construction de la charpente, toujours suivre les codes et standards de construction en vigueur.
HD1026F
CADRE DERRIÈRE
LE
MUR
MONTANTS
5
5. INSTALLER LE SUPPORT DE MONTAGE DU CONDUIT DÉCORATIF SUPÉRIEUR
Centrer le support de montage du conduit décoratif supérieur selon la
ligne précédemment tracée à l’étape 4 et le positionner au ras du plafond.
S’assurer que les fentes du support soient positionnées vers le bas.
Utiliser le support comme gabarit pour marquer la position des vis.
Percer deux trous à l’aide d’une mèche de 5/16 po. Insérer les douilles à
expansion (fournies) dans les trous percés (une pour chaque trou).
Fixer au mur le support de montage du conduit supérieur à l’aide de
2 vis n° 8 x 1½ po. S’assurer que le support de montage soit bien appuyé
contre le mur.
C
L
HD1027
CENTRE DE L'INSTALLATION
PLAFOND
SUPPORT DE MONTAGE
AU RAS DU PLAFOND
FENTES DU SUPPORT
DE MONTAGE DU CONDUIT
DÉCORATIF SUPÉRIEUR
6. RETIRER LES FILTRES À GRAISSES
Poser le dos de la hotte à plat sur une table. Placer au préalable un
morceau de carton pour éviter d’endommager la table et la hotte.
Retirer les filtres à graisses en tirant le loquet de métal vers le bas et en
faisant basculer chaque filtre vers le bas. Mettre les filtres de côté.
HD1028
7. INSTALLER L'ADAPTATEUR/VOLET DE 6 PO ROND
Fixer l’adaptateur/volet de 6 po rond à l’aide de 4 vis n° 8 x 5/16 po (incluses). Sceller
l’adaptateur à la hotte à l’aide de ruban adhésif de métal.
INSTALLATION EN RECIRCULATION : Retirer les deux volets.
HJ0156
VOLETS
8. INSTALLER LA HOTTE
1. Aligner la hotte et la centrer au-dessus de son support de montage. Abaisser doucement la hotte jusqu’à ce qu’elle s’accroche à son support.
2. Mettre la hotte de niveau.
3. Une fois la hotte en place, percer à travers les 2 trous situés au bas du dos
interne de la hotte à l’aide d’une mèche de 5/16 po (voir l'illustration ci-contre).
4. Insérer les douilles à expansion fournies dans les trous percés (une pour
chaque trou).
5. S'assurer que la hotte est toujours centrée et de niveau.
6. Insérer les 2 vis de montage n° 8 x 1½ po dans les 2 rondelles, puis les
visser dans les douilles à expansion. Serrer complètement toutes les vis.
VUE
LATÉRALE
EMPLACEMENT DES TROUS (Ø 5/16 PO TYP.)
E
NSEMBLE
MOTEUR
/VENTILATEUR
ADA PTATEUR/VOLET
HD1029F
AVERTISSEMENT
!
SOYEZ PRUDENT lors de l’installation du conduit décoratif et de la hotte, il pourrait y avoir des arêtes vives.
ATTENTION
NE PAS RETIRER pour l’instant le film protecteur de plastique recouvrant le conduit décoratif (supérieur et
inférieur) et la hotte.
6
9. RACCORDER LE CONDUIT
INSTALLATION EN ÉVACUATION VERTICALE :
Brancher le cordon d’alimentation de la hotte dans la prise murale.
Glisser une section de conduit rond en métal de 6 po par-dessus l’adaptateur/volet. Sceller
hermétiquement le joint à l’aide de ruban adhésif de métal.
HJ0157
INSTALLATION EN ÉVACUATION HORIZONTALE :
Brancher le cordon d’alimentation de la hotte dans la prise murale. Mesurer et installer
un conduit rond en métal de 6 po jusqu'au capuchon mural et un coude de 90° sur
l'adaptateur/volet de la hotte. Sceller hermétiquement les joints à l’aide de ruban adhésif
de métal.
HJ0159
1PO
MAX.
S
UPPORT DE MONTAGE
CONDUIT
DÉCORATIF INFÉRIEUR
HD1033F
NOTE : Afin qu’il y ait suffisamment d’espace entre le dessus de la hotte et le support de
montage du conduit décoratif inférieur, le coude doit être situé en dessous du
support de montage pour laisser passer le conduit.
7
À l'aide de 4 vis ST4 x 8 incluses, assembler l’adaptateur rond de 6 po au plenum.
INSTALLATION EN RECIRCULATION :
Brancher le cordon d’alimentation de la hotte dans la prise murale.
Mesurer la longueur requise de conduit flexible rond de 6 po en métal (inclus dans le kit de
recirculation) pour couvrir la distance entre le dessus de la hotte et le plafond. Glisser le
conduit flexible rond de 6 po en métal par-dessus l’adaptateur (sans les volets) de la hotte
et le fixer avec une attache autobloquante incluse.Sceller le joint avec du ruban adhésif
de métal.
HJ0158
9. RACCORDER LE CONDUIT (SUITE)
FRONT
HA0138
Fixer le conduit flexible de métal à l'adaptateur à l'aide d'une attache autobloquante (incluse).
S'assurer que le côté « FRONT » est installé à l'avant de la hotte.
Sceller le joint avec du ruban adhésif de métal.
FRONT
HJ0160
8
10. PRÉPARER LE CONDUIT DÉCORATIF
FENTES
HO0285
ENCOCHE
ARRIÈRE DU
CONDUIT
INFÉRIEUR
Enlever juste assez de plastique protecteur pour dégager les coins supérieurs du conduit décoratif
supérieur.
NOTE : Uniquement pour une installation sans conduit, enlever assez de plastique pour dégager
les fentes.
Positionner les encoches arrière du conduit inférieur vers le bas.
Glisser délicatement le conduit décoratif supérieur dans le conduit décoratif inférieur, le côté des
fentes vers le haut.
Retirer le conduit décoratif supérieur de l'intérieur du conduit décoratif inférieur. Retirer la
pellicule de plastique protectrice recouvrant le conduit décoratif inférieur seulement. Assembler
le support de montage du conduit décoratif inférieur à celui-ci à l’aide de 2 vis de montage
n° 8 x 5/16 po en vous assurant que les fentes soient placées vers le haut.
HO0114
VUE ARRIÈRE DU SUPPORT DE MONTAGE
DU CONDUIT DÉCORATIF INFÉRIEUR
FENTES VERS
LE HAUT
CONDUIT
INFÉRIEUR
Les conduits décoratifs inférieur et supérieur sont inclus avec la hotte. Toutefois, pour un plafond
de 10 pieds, se défaire du conduit décoratif supérieur et utiliser le conduit décoratif supérieur
optionnel, pièce n° FXN58SS (vendu séparément).
11. INSTALLER LE CONDUIT DÉCORATIF
Glisser délicatement en place le conduit décoratif (le côté des encoches en premier) dans la
rainure sur le dessus de la hotte. Remonter légèrement le conduit supérieur afin d’éviter de
l’endommager puis assembler le conduit décoratif inférieur au dessus de la hotte à l'aide de
2 vis n° 8 x 5/16 po à travers ses fentes latérales.
HO0286
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

NuTone NW830SS Manuel utilisateur

Catégorie
Hottes
Taper
Manuel utilisateur

dans d''autres langues