Maytag MGC7430DB Guide d'installation

Taper
Guide d'installation

Ce manuel convient également à

INSTALLATION INSTRUCTIONS
30" (76.2 CM) AND 36" (91.4 CM)
GAS BUILT-IN COOKTOP
INSTRUCTIONS D'INSTALLATION
DE LA TABLE DE CUISSON À GAZ ENCASTRÉE DE
30" (76,2 CM) ET 36" (91,4 CM)
Table of Contents/Table des matières
COOKTOP SAFETY........................................................................2
INSTALLATION REQUIREMENTS ................................................3
Tools and Parts ............................................................................3
Location Requirements................................................................3
Electrical Requirements ...............................................................7
Gas Supply Requirements ...........................................................7
INSTALLATION INSTRUCTIONS ..................................................9
Install Cooktop .............................................................................9
Make Gas Connection .................................................................9
Complete Installation .................................................................11
SÉCURITÉ DE LA TABLE DE CUISSON ....................................13
EXIGENCES D'INSTALLATION...................................................14
Outillage et pièces......................................................................14
Exigences d’emplacement.........................................................14
Spécifications électriques ..........................................................18
Spécifications de l'alimentation en gaz .....................................18
INSTRUCTIONS D’INSTALLATION.............................................20
Installation de la table de cuisson..............................................20
Raccordement au gaz................................................................20
Achever l’installation ..................................................................22
W10597144B
IMPORTANT:
Installer: Leave installation instructions with the homeowner.
Homeowner: Keep installation instructions for future reference.
IMPORTANT :
Installateur : Remettre les instructions d'installation au propriétaire.
Propriétaire : Conserver les instructions d'installation pour référence ultérieure.
2
COOKTOP SAFETY
You can be killed or seriously injured if you don't immediately
You
can be killed or seriously injured if you don't
follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
WARNING: If the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury or death.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or
the gas supplier.
WARNING: Gas leaks cannot always be detected by smell.
Gas suppliers recommend that you use a gas detector approved by UL or CSA.
For more information, contact your gas supplier.
If a gas leak is detected, follow the “What to do if you smell gas” instructions.
IMPORTANT: Do not install a ventilation system that blows air downward toward this gas cooking appliance. This type of
ventilation system may cause ignition and combustion problems with this gas cooking appliance resulting in personal injury or
unintended operation.
3
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Tools needed
Parts supplied
Parts needed
Check local codes and consult gas supplier. Check existing gas
supply and electrical supply. See “Electrical Requirements” and
“Gas Supply Requirements” sections.
Location Requirements
IMPORTANT: Observe all governing codes and ordinances. Do
not obstruct flow of combustion and ventilation air.
It is the installer’s responsibility to comply with installation
clearances specified on the model/serial rating plate. The
model/serial rating plate is located on the underside of the
cooktop base.
To eliminate the risk of burns or fire by reaching over heated
surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be
provided, the risk can be reduced by installing a range hood
that projects horizontally a minimum of 5" (12.7 cm) beyond
the bottom of the cabinets.
The cooktop must be a specified cooktop that is approved to
be installed either alone or over an undercounter built-in
oven. Check the cooktop base approved installation label for
your cooktop model number and approved combinations of
cooktops and ovens that can be installed. If you do not find
this label, your cooktop may not be approved for use over an
undercounter built-in oven. Contact your dealer to confirm
that your cooktop is approved.
Ovens approved for this type of installation will have an
approval label located on the top of the oven. If you do not
find this label, contact your dealer to confirm that your oven is
approved. Refer to oven manufacturer’s Installation
Instructions for approval for built-in undercounter use and
proper cutout dimensions.
The cooktop should be installed in a location away from
strong draft areas, such as windows, doors and strong
heating vents or fans.
All openings in the wall or floor where cooktop is to be
installed must be sealed.
Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances.
Grounded electrical supply is required. See “Electrical
Requirements” section. Proper gas supply connection must
be available. See “Gas Supply Requirements” section.
The cooktop is designed to hang from the countertop by its
side or rear flanges.
The gas and electric supply should be located as shown in
“Cabinet Dimensions” section so that they are accessible
without requiring removal of the cooktop.
Provide cutout in right rear corner of cutout enclosure as
shown to provide clearance for gas inlet, power supply cord,
and to allow the rating label to be visible.
IMPORTANT: To avoid damage, check with your builder or
cabinet supplier to make sure that the materials used will not
discolor, delaminate or sustain other damage.
Mobile Home - Additional Installation Requirements
The installation of this cooktop must conform to the
Manufactured Home Construction and Safety Standard, Title
24 CFR, Part 3280 (formerly the Federal Standard for Mobile
Home Construction and Safety, Title 24, HUD Part 280). When
such standard is not applicable, use the Standard for
Manufactured Home Installations, ANSI A225.1/NFPA 501A or
with local codes.
In Canada, the installation of this cooktop must conform with the
current standards CAN/CSA-A240-latest edition, or with local
codes.
In the State of Massachusetts, the following installation instructions apply:
Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
If using a ball valve, it shall be a T-handle type.
A flexible gas connector, when used, must not exceed 3 feet.
Tape measure
Flat-blade screwdriver
Phillips screwdriver
¹⁵⁄₁₆" combination wrench
Pipe wrench
Wrench or pliers
Marker or pencil
Pipe-joint compound
resistant to LP gas
Noncorrosive leak-detection
solution
Gas pressure regulator
Burner grates
Burner caps
Burner base
Clamping brackets (2)
Bracket attachment
screws (2)
A. Model/serial rating plate
A
4
Product Dimensions
KCGS550ESS and KCGS950ESS Models
All Other 30" (76.2 cm) Models
KCGS556ESS and KCGS956ESS Models
All Other 36" (91.4 cm) Models
A. 21" (53.3 cm)
B. 30" (76.2 cm)
C. 19
³⁄₈
" (49.2 cm)
D. 28
³⁄₈
" (72.1 cm)
E. 3
⁵⁄₈
" (9.2 cm)
F. 4
⁹⁄₁₆
" (11.6 cm)
G. 1
³⁄₈
" (3.4 cm)
A. 21" (53.3 cm)
B. 30" (76.2 cm)
C. 18
⁷⁄₈
" (48.0 cm)
D. 28
³⁄₈
" (72.1 cm)
E. 3
³⁄₈
" (8.6 cm)
F. 4
¹⁄₈
" (10.5 cm)
G. 1
¹⁄₂
" (3.8 cm)
A
C
D
B
E
F
G
A
B
C
D
E
F
G
A. 21" (53.3 cm)
B. 36
¹⁄₄
" (92.0 cm)
C. 19
³⁄₈
" (49.2 cm)
D. 34
³⁄₈
" (88.1 cm)
E. 3
⁵⁄₈
" (9.2 cm)
F. 4
⁵⁄₁₆
" (11.6 cm)
G. 1
⁷⁄₁₆
" (3.6 cm)
A. 21" (53.3 cm)
B. 36" (91.4 cm)
C. 18
⁷⁄₈
" (48.0 cm)
D. 33
³⁄₄
" (85.7 cm)
E. 3
³⁄₈
" (8.6 cm)
F. 4
¹⁄₈
" (10.5 cm)
G. 1½" (3.8 cm)
A
B
C
D
E
F
G
D
A
B
C
E
F
G
5
Cabinet Clearances
Side View Front View
A. 13" (33.0 cm) recommended upper cabinet depth.
B. 30" (76.2 cm) for 30" models; 36" (91.4 cm) for 36" models.
C. 18" (45.7 cm) minimum clearance from upper cabinet to countertop
within minimum horizontal clearances to cooktop.
D. 30" (76.2 cm) minimum clearance between top of cooktop platform
and bottom of uncovered wood or metal cabinet.
24" [61 cm] minimum clearance if bottom of wood or metal cabinet
is covered by not less than ¹⁄₄" [0.6 cm] flame retardant millboard
covered with not less than No. 28 MSG sheet steel, 0.015" [0.04 cm]
stainless steel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm]
copper.
E. 36" (91.4 cm) top of countertop to floor.
F. Gas line opening - Wall: anywhere 5" (12.7 cm) below underside of
countertop. Cabinet floor: anywhere within 6" (15.2 cm) of rear wall
is recommended.
B
A
C
D
F
E
6
Cutout Dimensions - Top View
NOTES: After making the countertop cutout, some installations may require notching down the base cabinet side walls to clear the
cooktop base. To avoid this modification, use a base cabinet with sidewalls wider than the cutout.
If cabinet has a drawer, a 4" (10.2 cm) depth clearance from the countertop to the top of the drawer (or other obstruction) in base
cabinet is required. The drawer depth may need to be shortened to avoid interfering with the regulator.
IMPORTANT: If a built-in wall oven is to be installed below this cooktop, the grounded outlet and gas supply piping must be located in
an adjacent cabinet.
This cooktop and its gas and electrical supply sources must be installed before the undercounter built-in wall oven is installed.
Back Wall
Side Wall Side Wall
Countertop Front Edge
Cutout (Product Opening) Dimensions
30" (76.2 cm) Models
Models A B
Min Recommended Max Min Recommended Max
KCGS550 and KCGS950
All Other 30" (76.2 cm)
Models
28
¹⁄₂
" (72.4 cm)
28
¹⁄₂
" (72.4 cm)
28
⁷⁄₈
" (73.4 cm)
28
⁷⁄₈
" (73.4 cm)
29
⁵⁄₁₆
" (74.3 cm)
29
⁵⁄₁₆
" (74.3 cm)
19
¹⁄₂
" (49.5 cm)
19" (48.3 cm)
19
¹³⁄₁₆
" (50.2 cm)
19
¹⁄₂
" (49.5 cm)
20" (50.8 cm)
20" (50.8 cm)
36" (91.4 cm)Models
KCGS556 and KCGS956
All Other 36" (91.4 cm)
Models
34
⁷⁄₈
" (88.4 cm)
33
⁷⁄₈
" (86.0 cm)
35
³⁄₁₆
" (89.4 cm)
34
⁵⁄₁₆
" (87.0 cm)
35
⁵⁄₈
" (90.3 cm)
35
¹⁄₄
" (89.5 cm)
19
¹⁄₂
" (49.5 cm)
19" (48.3 cm)
19
¹³⁄₁₆
" (50.2 cm)
19
¹⁄₂
" (49.5 cm)
20" (50.8 cm)
20" (50.8 cm)
Side Walls (Combustible Surfaces)
Models H and I
KCGS5 and KCGS9 H and I added together must be at least 48" (122.0 cm),
with each side individually being at least 8" (20.3 cm).
KCGS350, KCGS356,
MGC9536, WCG97US0,
WCG97US6
H and I added together must be at least 48" (122.0 cm),
with each side individually being at least 12" (30.5 cm).
All Other Models Both have to be 8" (20.3 cm) or more.
Back Wall and Countertop Front Dimensions
Models C D E
KCGS550 and KCGS950
25" (63.5 cm) 2
⁷⁄₈
" (7.3 cm)
2
³⁄₄
" (6.9 cm)
All Other Models 3
¹⁄₈
" (7.9 cm)
7
Electrical Requirements
IMPORTANT: The cooktop must be electrically grounded in
accordance with local codes and ordinances, or in the absence
of local codes, with the National Electrical Code, ANSI/NFPA 70
or Canadian Electrical Code, CSA C22.1.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
A 120 volt, 60 Hz, AC only, 15-amp, fused electrical circuit is
required. A time-delay fuse or circuit breaker is also
recommended. It is recommended that a separate circuit
serving only this cooktop be provided.
Electronic ignition systems operate within wide voltage limits,
but proper grounding and polarity are necessary. Check that
the outlet provides 120-volt power and is correctly grounded.
The wiring diagrams are provided with this cooktop. See
“Wiring Diagrams” on a separate sheet. The wiring diagrams
are located on the left underside of the cooktop base.
Gas Supply Requirements
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes
and ordinances. In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest
edition.
IMPORTANT: Leak testing of the cooktop must be conducted
according to the manufacturer’s instructions.
Type of Gas
Natural Gas:
This cooktop is factory set for use with Natural gas. If
converting to LP gas, see the “LP Gas Conversion”
instructions provided in the package containing literature.
The model/serial rating plate located on the underside of the
cooktop base has information on the types of gas that can be
used. If the types of gas listed do not include the type of gas
available, check with the local gas supplier.
LP Gas Conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the cooktop from the gas
specified on the model/serial rating plate for use with a different
gas without consulting the serving gas supplier. See the Gas
Conversion instructions provided in the package con
taining
literature.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
8
Gas Supply Line
Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the
cooktop location. A smaller size pipe on longer runs may
result in insufficient gas supply. Pipe-joint compounds that
resist the action of LP gas must be used. Do not use
TEFLON
®†
tape. With LP gas, piping or tubing size should be
½" minimum. Usually, LP gas suppliers determine the size
and materials used in the system.
Flexible metal appliance connector:
If local codes permit, use a ¹⁄₂" or ³⁄₄" I.D. flexible stainless
steel tubing gas connector, designed by CSA to connect
the cooktop to the rigid gas supply line.
A ½" male pipe thread is needed for connection to the
female pipe threads of the inlet to the cooktop pressure
regulator.
Do not kink or damage the flexible metal tubing when
moving the cooktop.
Must include a shutoff valve:
The supply line must be equipped with a manual shutoff
valve. This valve should be located in the same room but
external to the cooktop opening, such as an adjacent
cabinet. It must be accessible without removing the cooktop,
and it should be in a location that allows ease of opening and
closing. Do not block access to shutoff valve. The valve is for
turning on or shutting off gas to the cooktop.
Gas Pressure Regulator
The gas pressure regulator supplied with this cooktop must be
used. The inlet pressure to the regulator should be as follows for
proper operation:
Natural Gas:
Minimum pressure: 5" (12.7 cm) WCP
Maximum pressure: 7" to 14" (17.8 cm to 35.5 cm) WCP
LP Gas:
Minimum pressure: 10" (25.4 cm) WCP
Maximum pressure: 14" (35.5 cm) WCP
Contact local gas supplier if you are not sure about the inlet
pressure.
Burner Input Requirements
Input ratings shown on the model/serial rating plate are for
elevations up to 2,000 ft (609.6 m).
For elevations above 2,000 ft (609.6 m), ratings should be
reduced at a rate of 4% for each 1,000 ft (304.8 m) above sea
level (not applicable for Canada).
Gas Supply Pressure Testing
Gas supply pressure for testing regulator must be at least
1" water column pressure above the manifold pressure shown on
the model/serial rating plate.
Line pressure testing above ½ psi gauge (14" WCP)
The cooktop and its individual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
½ psi (3.5 kPa).
Line pressure testing at ½ psi gauge (14" WCP) or lower
The cooktop must be isolated from the gas supply piping system
by closing its individual manual shutoff valve during any pressure
testing of the gas supply piping system at test pressures equal to
or less than ½ psi (3.5 kPa).
A. Gas supply line
B. Shutoff valve “open” position
C. To cooktop
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
A
B
C
9
INSTALLATION INSTRUCTIONS
Install Cooktop
Decide on the final location for the cooktop. Avoid drilling into or
severing existing wiring during installation.
1. Determine whether your cabinet construction provides
clearance for installing clamping brackets at cooktop base
ends. This is the recommended location. Clamping brackets
can be installed on the front and back of cooktop base
bottom, if necessary.
2. Using 2 or more people, place cooktop right side up into the
cutout.
NOTE: Make sure that the front edge of the cooktop is
parallel to the front edge of the countertop. If repositioning is
needed, lift entire cooktop up from cutout to avoid scratching
the countertop.
3. Remove the attachment screws for the selected bracket
locations from the bottom of the cooktop base.
4. Attach brackets to cooktop base bottom with bracket
attachment screws. Securely tighten screws.
Make Gas Connection
Typical flexible connection
1. Apply pipe-joint compound made for use with Natural and LP
gas to the smaller thread ends of the flexible connector
adapters (see C and G in the following illustration).
2. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.
A. Attachment screw holes for optional front and back location
B. Cooktop base bottom
C. Attachment screw
D. Clamping bracket (end locations recommended)
A. Edge of cooktop base bottom
B. Clamping bracket
WARNING
Excessive Weight Hazard
Use two or more people to move and install cooktop.
Failure to do so can result in back or other injury.
B
C
C
D
A
A
B
A. Cooktop
B. Cooktop base
C. 2" (5.1 cm) bracket attachment screw
D. Clamping bracket (extends far
enough beyond cooktop base to
allow installation of clamping screws)
E. Countertop
A
B
C
D
E
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
10
3. Use a ¹⁵⁄₁₆" combination wrench and channel lock pliers to
attach the flexible connector to the adapters. Check that
connector is not kinked.
IMPORTANT: All connections must be wrench-tightened. Do
not make connections to the gas regulator too tight. Making
the connections too tight may crack the regulator and cause
a gas leak. Do not allow the regulator to turn when tightening
fittings.
4. Install the pressure regulator with the arrow pointing in the
direction toward the bottom of the cooktop base and in a
position where you can reach the regulator access cap.
Use only pipe-joint compound made for use with Natural and LP
gas.
Do not use TEFLON
®
tape. You will need to determine the fittings
required depending on your installation.
Complete Connection
1. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
2. Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.
3. Remove surface burner caps, burner base and grates from
parts package. Align notches in burner caps with pins in
burner base.
Align orifice holder in burner base with igniter electrode.
Burner caps should be level when properly positioned. If
burner caps are not properly positioned, surface burners will
not light. Place burner grates over burners and caps.
No appliance/obstructions
below cooktop
Suggested installation to
avoid interference below
cooktop
A. Manifold entrance
B. Gas pressure regulator
C. Use pipe-joint compound.
D. Adapter (must have ½" male
pipe thread)
E. Flexible connector
F. A d ap t er
G. Use pipe-joint compound.
H. Manual gas shutoff valve
I. ½" or ¾" gas pipe
A. Manifold entrance
B.
³⁄₈
" elbow
C. Use pipe-joint compound.
D. Adapter (must have
³⁄₈
" male
pipe thread)
E. Flexible connector (pass
through wall between
cabinets)
F. Adapter (must have
³⁄₈
" male
pipe thread)
G. Use pipe-joint compound.
H. Appliance pressure regulator
(supplied)
I. ½" or ¾" gas pipe
J. Manual gas shutoff valve
K. ½" or ¾" gas pipe
A
B
D
E
C
F
G
H
I
A
B
C
D
F
I
J
K
H
E
G
A. Access cap
B. Rear of cooktop
C. Gas pressure regulator
D. Up arrow. The regulator must be
installed with the arrow pointing
toward the cooktop bottom.
A. Closed valve
B. Open valve
A. Orifice holder
B. Burner cap
C. Gas tube opening
D. Burner base
E. Igniter electrode
A
B
C
D
A
B
B
C
D
E
A
11
4. Plug into a grounded 3 prong outlet.
Complete Installation
Electronic Ignition System
Initial lighting and gas flame adjustments
Surface burners use electronic igniters in place of standing pilots.
When the cooktop control knob is turned to the “IGNITE”
position, the system creates a spark to light the burner. This
sparking continues, as long as the control knob is turned to
“IGNITE.”
Check Operation of Surface Burners
Push in and turn the surface burners control knobs to light.
The surface burner flame should light within 4 seconds. The first
time a surface burner is lit, it may take longer that 4 seconds to
light because of air in the gas line.
Check the flame on “HIGH” for a blue color. It should be clean
and soft in character. No yellow tip, blowing or lifting of flame
should occur. Occasional orange flashes are normal and reflect
different elements in the air or gas.
After verifying the proper burner operation, turn the control knobs
to “OFF.”
If burners do not light properly:
Turn surface burner control knob to the “OFF” position.
Check that the power supply cord is plugged in and the
circuit breaker has not tripped or the fuse blown.
Check that the gas shutoff valve is set to the “open” position.
Check that burner caps are properly positioned on burner
bases.
Recheck operation of surface burners. If a burner does not light
at this point, contact your dealer or authorized service company
for assistance.
Check Flame Height
Adjust the height of surface burner flames.
The surface burner “low” flame should be a steady blue flame
approximately ¼" (6.4 mm) high.
Adjustment for Single Valve:
1. Set the burner flame to LO.
2. Remove the control knob.
3. Hold knob stem with a pair of pliers. Use a ³⁄₃₂" (#0 [2 mm])
flat-blade screwdriver to turn the screw located within the
shaft of the control knob stem until the flame is the proper
size.
Turn adjustment screw “C” to the right to reduce flame
height, turn adjustment screw to the left to increase flame
height.
4. Replace the control knob.
5. Test the flame by turning the control from LO to HI, checking
the flame at each setting
IMPORTANT: Dual valve adjustments must be performed by a
qualified installer or service agency.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
A. Low flame
B. High flame
A.
³⁄₃₂
" (#0 [2.0 mm]) flat-blade screwdriver
(screwdriver shaft must be a minimum of
2" [5.1 cm] long)
B. Control knob stem opening
C. Adjustment screw location
A
B
B
C
A
12
Notes
13
SÉCURITÉ DE LA TABLE DE CUISSON
Risque possible de décès ou de blessure grave si vous ne
suivez pas immédiatement les instructions.
Risque possible de décès ou de blessure grave si vous
ne suivez pas les instructions.
Tous les messages de sécurité vous diront quel est le danger potentiel et vous disent comment réduire le risque de blessure et
ce qui peut se produire en cas de non-respect des instructions.
Votre sécurité et celle des autres est très importante.
Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de
toujours lire tous les messages de sécurité et de vous y conformer.
AVERTISSEMENT
DANGER
Voici le symbole d’alerte de sécurité.
Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous
et à d’autres.
Tous les messages de sécurité suivront le symbole d’alerte de sécurité et le mot “DANGER” ou
“AVERTISSEMENT”. Ces mots signifient :
AVERTISSEMENT : Si les renseignements dans ce manuel ne sont pas exactement
observés, un incendie ou une explosion peut survenir, causant des dommages au
produit, des blessures ou un décès.
Ne pas entreposer ni utiliser de l’essence ou d’autres vapeurs ou liquides inflammables
à proximité de cet appareil ou de tout autre appareil électroménager.
QUE FAIRE DANS LE CAS D’UNE ODEUR DE GAZ :
Ne pas tenter d’allumer un appareil.
Ne pas toucher à un commutateur électrique.
Ne pas utiliser le téléphone se trouvant sur les lieux.
Appeler immédiatement le fournisseur de gaz à partir du téléphone d'un voisin. Suivre
ses instructions.
À défaut de joindre votre fournisseur de gaz, appeler les pompiers.
L’installation et l’entretien doivent être effectués par un installateur qualifié, une agence
de service ou le fournisseur de gaz.
AVERTISSEMENT : L’odorat ne permet pas toujours la détection d’une fuite de gaz.
Les distributeurs de gaz recommandent l’emploi d’un détecteur de gaz (homologation UL ou CSA).
Pour d’autre information, contacter le fournisseur de gaz local.
En cas de détection d’une fuite de gaz, exécuter les instructions “Que faire dans le cas d’une odeur de gaz”.
IMPORTANT : Ne pas installer un système de ventilation avec évacuation de l'air vers le bas, qui évacuerait l'air vers cet
appareil de cuisson à gaz. Ce type de système de ventilation peut causer des problèmes d'allumage et de combustion avec cet
appareil de cuisson à gaz et entraîner des blessures corporelles ou le fonctionnement non désiré de cet appareil.
14
EXIGENCES D'INSTALLATION
Outillage et pièces
Rassembler les outils et pièces nécessaires avant de commencer
l'installation.
Outillage nécessaire
Pièces fournies
Pièces nécessaires
Vérifier les codes locaux et consulter le fournisseur de gaz.
Vérifier l'alimentation en gaz et l'alimentation électrique
existantes. Voir les sections “Spécifications électriques” et
“Spécifications de l'alimentation en gaz”.
Exigences d’emplacement
IMPORTANT : Observer les dispositions de tous les codes et
règlements en vigueur. Ne pas obstruer le flux de combustion et
de ventilation.
C'est à l'installateur qu'incombe la responsabilité de
respecter les distances de séparation spécifiées sur la plaque
signalétique. La plaque signalétique se trouve sur le dessous
de la base de la table de cuisson.
Afin de supprimer le risque de brûlures ou d’incendie lié au
fait de se pencher au-dessus des plaques de cuisson
chaudes, les placards de rangement au-dessus des plaques
doivent être évités. Si des placards de rangement sont
envisagés, le risque peut être réduit par l’installation d’une
hotte de cuisinière dépassant le bas des placards d’au moins
5" (12,7 cm) horizontalement.
La table de cuisson doit être une table de cuisson spécifiée,
et doit être approuvée pour une installation seule ou sur un
four encastré sous comptoir. Vérifier que la base de la table
de cuisson comporte une étiquette d’installation approuvée
pour le numéro de modèle de votre table de cuisson et les
combinaisons approuvées de tables de cuisson et de fours
qui peuvent être installés. Si vous ne trouvez pas cette
étiquette, il se peut que votre table de cuisson ne soit pas
approuvée pour une utilisation au-dessus d’un four encastré
sous comptoir. Contacter le marchand pour confirmer que
votre table de cuisson est bien approuvée.
Les fours approuvés pour ce type d’installation comportent
une étiquette d’approbation située sur le dessus du four. Si
vous ne trouvez pas cette étiquette, contactez votre
marchand pour confirmer que le four est bien approuvé.
Consulter les Instructions d’installation du fabricant du four
pour obtenir l’approbation de l’utilisation en encastrement et
les dimensions correctes.
La table de cuisson doit être installée dans un emplacement à
l’écart des zones de forts courants d’air, telles que fenêtres,
portes et évents ou ventilateurs de chauffage.
Toutes les ouvertures dans le mur ou le plancher de
l’emplacement d’installation de la table de cuisson doivent
être scellées.
Respecter les dimensions indiquées pour les ouvertures à
découper dans les meubles. Ces dimensions constituent les
valeurs minimales des dégagements.
Une source d’électricité avec liaison à la terre est nécessaire.
Voir la section “Spécifications électriques”. Un raccordement
adéquat à l’alimentation en gaz doit être disponible. Voir la
section “Spécifications de l’alimentation en gaz”.
De par sa conception, la table de cuisson est retenue sur le
plan de travail par ses rebords latéraux ou arrière.
Veiller à placer les sources de gaz et d'électricité selon les
indications de la section “Dimensions du placard” pour
qu'elles soient accessibles sans avoir à retirer la table de
cuisson.
Prévoir une ouverture dans l'angle supérieur droit de
l'enceinte – voir l'illustration – pour le passage de la
canalisation de gaz et du câble d'alimentation électrique et
pour que l'étiquette signalétique soit visible.
IMPORTANT : Pour éviter tout dommage, consulter le
constructeur de la maison ou le fabricant de placards pour
déterminer si les matériaux utilisés peuvent subir un changement
de couleur, une déstratification ou autres dommages.
Dans l’État du Massachusetts, les instructions d’installation suivantes sont applicables :
Les travaux d’installation et réparation doivent être exécutés par un plombier ou tuyauteur qualifié ou licencié, ou par le
personnel qualifié d’une entreprise licenciée par l’État du Massachusetts.
Si une vanne à boisseau sphérique est utilisée, elle doit comporter une manette “T”.
Si un conduit de raccordement flexible est utilisé, sa longueur ne doit pas dépasser 3 pi.
Mètre-ruban
Tournevis à lame plate
Tournevis Phillips
Clé mixte de ¹⁵⁄₁₆"
Clé à tuyauteries
Clé ou pince
Marqueur ou crayon
Composé d'étanchéité pour
tuyauteries - résistant au
propane
Solution non corrosive de
détection des fuites
Détendeur
Grilles de brûleur
Chapeaux de brûleur
Base des brûleurs
Brides de serrage (2)
Vis de fixation de bride (2)
A. Plaque signalétique
A
15
Résidence mobile – Spécifications additionnelles à
respecter lors de l’installation
L’installation de cette table de cuisson doit être conforme aux
dispositions de la norme Manufactured Home Construction and
Safety Standard, Titre 24 CFR, partie 3280 (anciennement
Federal Standard for Mobile Home Construction and Safety, Titre
24, HUD partie 280). Lorsque cette norme n’est pas applicable,
l’installation doit satisfaire aux critères de la norme Standard for
Manufactured Home Installations, ANSI A225.1/NFPA 501A ou
aux dispositions des codes locaux.
Au Canada, l'installation de cette table de cuisson doit satisfaire
aux stipulations de la version la plus récente de la norme CAN/
CSA-A240 ou des codes locaux en vigueur.
Dimensions du produit
Modèles KCGS550ESS et KCGS950ESS
Tous les autres modèles de 30" (76,2 cm)
Modèles KCGS556ESS et KCGS956ESS
Tous les autres modèles de 36" (91,4 cm)
A. 21" (53,3 cm)
B. 30" (76,2 cm)
C. 19
³⁄₈
" (49,2 cm)
D. 28
³⁄₈
" (72,1 cm)
E. 3
⁵⁄₈
" (9,2 cm)
F. 4
⁹⁄₁₆
" (11,6 cm)
G. 1
³⁄₈
" (3,4 cm)
A. 21" (53,3 cm)
B. 30" (76,2 cm)
C. 18
⁷⁄₈
" (48 cm)
D. 28
³⁄₈
" (72,1 cm)
E. 3
³⁄₈
" (8,6 cm)
F. 4
¹⁄₈
" (10,5 cm)
G. 1
¹⁄₂
" (3,8 cm)
A
C
D
B
E
F
G
A
B
C
D
E
F
G
A. 21" (53,3 cm)
B. 36
¹⁄₄
" (92 cm)
C. 19
³⁄₈
" (49,2 cm)
D. 34
³⁄₈
" (88,1 cm)
E. 3
⁵⁄₈
" (9,2 cm)
F. 4
⁵⁄₁₆
" (11,6 cm)
G. 1
⁷⁄₁₆
" (3,6 cm)
A. 21" (53,3 cm)
B. 36" (91,4 cm)
C. 18
⁷⁄₈
" (48 cm)
D. 33
³⁄₄
" (85,7 cm)
E. 3
³⁄₈
" (8,6 cm)
F. 4
¹⁄₈
" (10,5 cm)
G. 1½" (3,8 cm)
A
B
C
D
E
F
G
D
A
B
C
E
F
G
16
Distances de dégagement à respecter
Vue latérale Vue de face
A. Profondeur recommandée des placards supérieurs de 13" (33 cm)
B. 30" (76,2 cm) pour les modèles de 30"; 36" (91,4 cm) pour les modèles
de 36".
C. Distance de séparation minimale de 18" (45,7 cm) entre le placard
supérieur et le plan de travail avec distance minimale de séparation
horizontale pour la table de cuisson
D. Dégagement minimum de 30" (76,2 cm) entre le sommet de la plate-
forme de la table de cuisson et le fond du placard de bois ou de métal
non protégé.
Dégagement minimum de 24" [61 cm] lorsque le fond du placard de
bois ou de métal est couvert d’une plaque ignifugée d’au moins ¹⁄₄" [0,6
cm] recouverte d’une tôle d’acier de 28 MSG, d’acier inoxydable de
0,015" [0,04 cm], d’aluminium de 0,024" [0,06 cm], ou de cuivre de
0,020" [0,05 cm] d’épaisseur au minimum.
E. 36" (91,4 cm) entre le sommet du plan de travail et le plancher.
F. Ouverture pour canalisation de gaz – mur : n’importe où, à 5" (12,7 cm)
au-dessous de la face inférieure du plan de travail. Plancher du placard :
n’importe où, à moins de 6" (15,2 cm) du mur arrière (recommandation).
B
A
C
D
F
E
17
Dimensions de l'ouverture à découper - Vue de dessus
REMARQUES : Après le découpage de l'ouverture dans le plan de travail, il est possible que pour certaines configurations
d'installation, il soit nécessaire d'entailler les parois latérales du placard inférieur pour permettre le passage de la base de la table de
cuisson. Pour éviter cette modification, utiliser un placard inférieur dont la largeur entre parois latérales est supérieure à celle de
l’ouverture découpée.
Si le placard comporte un tiroir, on devra ménager un dégagement de 4" (10,2 cm) ou plus entre le plan de travail et le dessus du tiroir
(ou autre obstacle) dans le placard inférieur. Il pourra être nécessaire de réduire la profondeur du tiroir pour éviter qu’il ne touche le
détendeur.
IMPORTANT : Si l'on doit installer un four mural encastré en-dessous de cette table de cuisson, la prise reliée à la terre et la
canalisation d'alimentation au gaz doivent être situées dans un placard adjacent.
Cette table de cuisson ainsi que son circuit électrique et son alimentation en gaz doivent être installés avant l'installation du four mural
encastré sous le plan de travail.
Mur arrière
Mur latéral Mur latéral
Bord avant du plan de travail
Dimensions des ouvertures à découper (ouverture du produit)
Modèles de 30" (76,2 cm)
Modèles A B
Min Recommandé Max Min Recommandé Max
KCGS550 et KCGS950
Tous les autres modèles de
30" (76,2 cm)
28
¹⁄₂
" (72,4 cm)
28
¹⁄₂
" (72,4 cm)
28
⁷⁄₈
" (73,4 cm)
28
⁷⁄₈
" (73,4 cm)
29
⁵⁄₁₆
" (74,3 cm)
29
⁵⁄₁₆
" (74,3 cm)
19
¹⁄₂
" (49,5 cm)
19" (48,3 cm)
19
¹³⁄₁₆
" (50,2 cm)
19
¹⁄₂
" (49,5 cm)
20" (50,8 cm)
20" (50,8 cm)
Modèles de 36” (91,4 cm)
KCGS556 et KCGS956
Tous les autres modèles de
36" (91,4 cm)
34
⁷⁄₈
" (88,4 cm)
33
⁷⁄₈
" (86 cm)
35
³⁄₁₆
" (89,4 cm)
34
⁵⁄₁₆
" (87 cm)
35
⁵⁄₈
" (90,3 cm)
35
¹⁄₄
" (89,5 cm)
19
¹⁄₂
" (49,5 cm)
19" (48,3 cm)
19
¹³⁄₁₆
" (50,2 cm)
19
¹⁄₂
" (49,5 cm)
20" (50,8 cm)
20" (50,8 cm)
Murs latéraux (surfaces combustibles)
Modèles H et I
KCGS5 et KCGS9 La longueur totale de H et I doit être de 48" (122 cm)
minimum, et chaque côté pris à part doit être d'au
moins 8" (20,3 cm)
KCGS350, KCGS356, MGC9536,
WCG97US0, WCG97US6
La longueur totale de H et I doit être de 48" (122 cm)
minimum, et chaque côté pris à part doit être d'au
moins 12" (30,5 cm)
Tous les autres modèles Tous deux doivent être de 8” (20,3 cm) ou plus.
Dimensions du mur arrière et de l'avant du plan de travail
Modèles C D E
KCGS550 et KCGS950
25" (63,5 cm) 2
⁷⁄₈
" (7,3 cm)
2
³⁄₄
" (6,9 cm)
Tous les autres modèles 3
¹⁄₈
" (7,9 cm)
18
Spécifications électriques
IMPORTANT : La table de cuisson doit être correctement reliée à
la terre en conformité avec les codes et règlements locaux en
vigueur, ou en l'absence de tels codes, avec le National Electrical
Code, ANSI/NFPA 70 ou le Code canadien des installations
électriques, CSA C22.1.
Si les codes le permettent et si on utilise un conducteur distinct
de liaison à la terre, il est recommandé qu'un électricien qualif
vérifie la qualide la liaison à la terre.
Pour obtenir un exemplaire de la norme des codes ci-dessus,
contacter :
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant
Valley Road
Cleveland, OH 44131-5575
L'appareil doit être alimenté par un circuit de 120 V, CA
seulement, 60 Hz, 15 ampères, protégé par fusible. On
recommande également d'utiliser un fusible ou un disjoncteur
temporisé. Il est recommandé de raccorder la table de
cuisson sur un circuit distinct exclusif à cet appareil.
Les systèmes d'allumage électronique fonctionnent avec des
limites de tension étendues, mais une liaison à la terre
correcte et une polarité appropriée sont nécessaires.rifier
que la prise fournit une alimentation de 120 V et qu'elle est
correctement reliée à la terre.
Les scmas deblage sont fournis avec cette table de
cuisson. Voir la section “Schémas de câblage” sur une feuille
séparée. Les schémas de câblage se trouvent sur la partie
inférieure de la base de la table de cuisson, du côté gauche.
Spécifications de l'alimentation en gaz
Observer les dispositions de tous les codes et règlements en
vigueur.
IMPORTANT : L'installation doit satisfaire aux critères de tous les
codes et règlements locaux. En l'absence de code local,
l'installation doit satisfaire aux prescriptions de la plus récente
édition du code national américain en vigueur : National Fuel Gas
Code ANSI Z223.1 ou à la norme CAN/CGA B149.
IMPORTANT : Les tests de fuite de la table de cuisson doivent
être effectués selon les instructions du fabricant.
Type de gaz
Gaz naturel :
Cette table de cuisson a été configurée à l'usine pour
l'alimentation au gaz naturel. Pour la conversion pour
l'alimentation au propane, voir les instructions “Conversion
pour l'alimentation au propane” dans le sachet de
documentation. La plaque signalétique située sur la face
inférieure de la base de la table de cuisson indique les types
de gaz utilisables. Si le type de gaz disponible n'est pas
mentionsur la plaque signalétique, consulter le fournisseur
de gaz local.
Conversion pour l'alimentation au propane :
L'opération de conversion doit être exécue par un technicien
de réparation qualifié.
Ne pas entreprendre de convertir la table de cuisson pour
l'utilisation d'un gaz différent de celui indiqué sur la plaque
signalétique sans d'abord consulter le fournisseur de gaz. Voir les
instructions de conversion de gaz fournies dans le sachet de
documentation.
AVERTISSEMENT
Risque de choc électrique
Brancher sur une prise à 3 alvéoles reliée à la terre.
Ne pas enlever la broche de liaison à la terre.
Ne pas utiliser un adaptateur.
Ne pas utiliser un câble de rallonge.
Le non-respect de ces instructions peut causer
un décès, un incendie ou un choc électrique.
AVERTISSEMENT
Risque d'explosion
Utiliser une canalisation neuve d'arrivée de gaz
approuvée par la CSA International.
Installer un robinet d'arrêt.
Bien serrer chaque organe de connexion de la
canalisation de gaz.
En cas de connexion au gaz propane, demander à une
personne qualifiée de s'assurer que la pression de gaz
ne dépasse pas 36 cm (14 po) de la colonne d'eau.
Par personne qualifiée, on comprend :
le personnel autorisé de chauffage,
le personnel autorisé d'une compagnie de gaz, et
le personnel d'entretien autorisé.
Le non-respect de ces instructions peut causer
un décès, une explosion ou un incendie.
19
Canalisation de gaz
Installer une canalisation de gaz rigide de ¾" (1,9 cm) jusqu'à
l'emplacement d'installation de la table de cuisson. L'emploi
d'une canalisation de plus petit diamètre sur un circuit plus
long peut causer une déficience du débit d'alimentation. On
doit utiliser un composé d'étanchéité des tuyauteries
résistant à l'action du gaz propane. Ne pas utiliser de ruban
TEFLON
®†
. Pour l'alimentation au propane, le diamètre du
tuyau ou conduit doit être de ½" ou plus. Usuellement, le
fournisseur de gaz propane détermine les matériaux à utiliser
et le diamètre approprié.
Raccord métallique flexible :
Si les codes locaux le permettent, utiliser un connecteur à
gaz flexible en acier inoxydable de ½" ou ¾" de diamètre
interne, conçu par CSA pour raccorder la table de
cuisson à la canalisation rigide d'alimentation en gaz.
Un raccord avec filetage mâle de ½" est nécessaire pour
la connexion sur le raccord à filetage femelle à l'entrée du
détendeur de la table de cuisson.
Ne pas déformer, écraser ou endommager le tube
métallique flexible lors d'un déplacement de la table de
cuisson.
Robinet d'arrêt nécessaire :
La canalisation d'alimentation doit comporter un robinet
d'arrêt manuel. Le robinet d'art manuel doit être séparé de
l'ouverture d'encastrement de la table de cuisson, mais doit
se trouver dans la même pièce, comme par exemple un
placard adjacent. II doit se trouver en un endroit facilement
accessible et qui ne nécessite pas le démontage de la table
de cuisson pour les manœuvres d'ouverture/fermeture. Ne
pas entraver l'accès au robinet d'arrêt manuel. Le robinet
d'arrêt manuel est prévu pour ouvrir ou fermer l'alimentation
en gaz de la table de cuisson.
Détendeur de gaz
Le détendeur fourni avec cette table de cuisson doit être utilisé.
La pression d'alimentation du détendeur doit être comme suit
pour un fonctionnement correct :
Gaz naturel :
Pression minimum : 5" (12,7 cm) (colonne d'eau)
Pression maximum : 7" à 14" (17,8 cm à 35,5 cm) (colonne d'eau)
Gaz propane :
Pression minimum : 10" (25,4 cm) (colonne d'eau)
Pression maximum : 14" (35,5 cm) (colonne d'eau)
En cas d'incertitude quant à la pression d'alimentation à établir,
contacter le fournisseur de gaz local.
Caractéristiques d'alimentation du brûleur
Les débits thermiques indiqués sur la plaque signalétique
correspondent à une altitude d'utilisation inférieure ou égale à
2000 pi (609,6 m).
Lorsque l'appareil est utilisé à une altitude supérieure à
2000 pi (609,6 m), on doit réduire le débit thermique indiqué
de 4 % pour chaque tranche de 1000 pi (304,8 m) au-dessus
du niveau de la mer (non applicable au Canada).
Test de pressurisation de la canalisation de gaz
On doit tester le détendeur sous une pression supérieure d'au
moins 1" (colonne d’eau) à la pression de la tubulure de
distribution indiquée sur la plaque signalétique.
Pressurisation à une pression supérieure à ½ lb/po²
(14" - colonne d'eau)
Lors de tout test de pressurisation de ce système à une pression
supérieure à ½ lb/po² (3,5 kPa), on doit déconnecter la table de
cuisson et son robinet d'arrêt individuel de la canalisation de gaz.
Pressurisation à une pression inférieure ou égale à ½ lb/po²
(14" - colonne d'eau)
Lors de tout test de pressurisation de la canalisation de gaz à une
pression égale ou inférieure à ½ lb/po² (3,5 kPa), on doit isoler la
table de cuisson de la canalisation de gaz en fermant son robinet
d'arrêt manuel individuel.
A. Canalisation de gaz
B. Robinet d'arrêt - position d'ouverture
C. Vers la table de cuisson
†®TEFLON est une marque déposée de E.I. Du Pont De Nemours et Compagnie
A
B
C
20
INSTRUCTIONS D’INSTALLATION
Installation de la table de cuisson
Déterminer l’emplacement final de la table de cuisson. Éviter de
percer dans le câblage existant ou de l'endommager pendant
l'installation.
1. Déterminer si l'installation des placards permet le
dégagement nécessaire pour l'installation de brides de
fixation aux extrémités de la base de la table de cuisson. Il
s'agit de l'emplacement recommandé. Des brides de fixation
peuvent être installées à l'avant et à l'arrière de la partie
inférieure de la base de la table de cuisson, si nécessaire.
2. À l'aide d'au moins 2 personnes, placer la table de cuisson
dans l'ouverture en orientant la bonne surface vers le haut.
REMARQUE : S’assurer que le bord avant de la table de
cuisson est parallèle au bord avant du plan de travail. S'il est
nécessaire de repositionner la table de cuisson, la soulever
entièrement de l'ouverture pour éviter de rayer le plan de
travail.
3. Enlever les vis d'attache pour les emplacements de brides
sélectionnés de la partie inférieure de la base de la table de
cuisson.
4. Fixer les brides sur le fond de la base de la table de cuisson à
l’aide des vis de fixation des brides. Bien serrer les vis.
Raccordement au gaz
Raccordement typique par raccord flexible
1. Appliquer un composé d'étanchéité pour tuyauteries conçu
pour une utilisation avec du gaz naturel et du gaz propane sur
l'extrémité filetée la plus petite des adaptateurs de raccord
flexible (voir C et G dans l'illustration ci-dessous).
2. Fixer un adaptateur sur le détendeur et l’autre adaptateur sur
le robinet d’arrêt de la canalisation de gaz. Serrer les deux
adaptateurs.
A. Trous de vis d’attache pour emplacement facultatif
à l’avant et à l’arrière
B. Fond de la base de la table de cuisson
C. Vis d'attache
D. Bride de fixation (emplacements aux extrémités
recommandés)
A. Partie inférieure de la base du
bord de la table de cuisson
B. Bride de fixation
AVERTISSEMENT
Risque du poids excessif
Utiliser deux ou plus de personnes pour déplacer et
installer la table de cuisson.
Le non-respect de cette instruction peut causer
une blessure au dos ou d'autre blessure.
B
C
C
D
A
A
B
A. Table de cuisson
B. Base de la table de cuisson
C. Vis d'attache de la bride de 2" (5,1 cm)
D. Bride de fixation (dépassant suffisamment
de la base de la table de cuisson pour
permettre l’installation des vis de fixation)
E. Plan de travail
A
B
C
D
E
AVERTISSEMENT
Risque d'explosion
Utiliser une canalisation neuve d'arrivée de gaz
approuvée par la CSA International.
Installer un robinet d'arrêt.
Bien serrer chaque organe de connexion de la
canalisation de gaz.
En cas de connexion au gaz propane, demander à une
personne qualifiée de s'assurer que la pression de gaz
ne dépasse pas 36 cm (14 po) de la colonne d'eau.
Par personne qualifiée, on comprend :
le personnel autorisé de chauffage,
le personnel autorisé d'une compagnie de gaz, et
le personnel d'entretien autorisé.
Le non-respect de ces instructions peut causer
un décès, une explosion ou un incendie.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Maytag MGC7430DB Guide d'installation

Taper
Guide d'installation
Ce manuel convient également à

dans d''autres langues