Sunbelt SPL375000 Le manuel du propriétaire

Taper
Le manuel du propriétaire

Ce manuel convient également à

OPERATOR’S MANUAL FOR
SH-375LP
SPAcE HEATER
Copyright 2006, A&I #37-0927-071806-E/F/S
120037-01
2 Operator’s Manual
Introduction
THANK YOU for purchasing this product.
READ THIS MANUAL carefully to learn how to operate
and service your machine correctly. Failure to do so
could result in personal injury or equipment damage.
This manual and safety signs on your machine may
also be available in other languages. (See your dealer
to order.)
THIS MANUAL SHOULD BE CONSIDERED a
permanent part of your machine and should remain
with the machine when you sell it.
MEASUREMENTS in this manual are given in both
metric and customary U.S. unit equivalents. Use only
correct replacement parts and fasteners. Metric and
inch fasteners may require a specic metric or inch
wrench.
The SERIAL NUMBER is located in the Specication
or Identication Numbers section. Accurately record all
the numbers to help in tracing the machine should it be
stolen. Your dealer also needs these numbers when you
order parts. File the identication numbers in a secure
place off the machine.
WARRANTY is provided from your dealer for customers
who operate and maintain their equipment as described
in this manual. The warranty is explained on the warranty
certicate shown in this manual.
This warranty provides you the assurance that your
dealer will back products where defects appear within the
warranty period. Should the equipment be abused, or
modied to change its performance beyond the original
factory specications, the warranty will become void.
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS
AND INSTRUCTIONS PROVIDED WITH THIS
HEATER, CAN RESULT IN DEATH, SERIOUS
BODILY INJURY AND PROPERTY LOSS
OR DAMAGE FROM HAZARDS OF FIRE,
EXPOSITION, BURN, ASPHYXIATION, AND/OR
CARBON MONOXIDE POISONING.
ONLY PERSONS WHO CAN UNDERSTAND AND
FOLLOW THE INSTRUCTIONS SHOULD USE
OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER
INFORMATION SUCH AS AN INSTRUCTIONS
MANUAL, LABELS, ETC. CONTACT THE
MANUFACTURER.
WARNING: FIRE, BURN, INHALATION
AND EXPLOSION HAZARD. KEEP SOLID
COMBUSTIBLES, SUCH AS BUILDING
MATERIALS, PAPER OR CARDBOARD, A
SAFE DISTANCE AWAY FROM THE HEATER
AS RECOMMENDED BY THE INSTRUCTIONS
NEVER USE THE HEATER IN SPACES WHICH
DO OR MAY CONTAIN VOLATILE OR AIRBORNE
COMBUSTIBLES OR PRODUCTS SUCH AS
GASOLINE, SOLVENTS, PAINT THINNER, DUST
PARTICLES OR UNKNOWN CHEMICALS.
WA RNIN G : NOT F O R HOM E O R
RECREATIONAL VEHICLE USE.
The heater is designed for use as a construction heater in
accordance with ANSI Z83.7/CGA 2.14. Other standards
govern the use of fuel gases and heating products for
specic uses. Your local authority can advise you about
these. The primary purpose of construction heaters is to
provide temporary heating of buildings under construction,
alteration or repair. Properly used, the heater provides
safe economical heating. Products of combustion are
vented into the area being heated.
We cannot foresee every use which may be made of our
heaters. Check with your local re safety authority if
you have questions about heater use.
Other standards govern the use of fuel gases and
heat producing products for specic uses. Your local
authorities can advise you about these.
Propane gas is odorless. An odor-making agent is added
to propane gas. The odor helps you detect a propane
gas leak. However, the odor added to propane gas can
fade. Propane gas may be present even though no
odor exists.
Install and use heater with care. Follow all local
ordinances and codes. In the absence of local
ordinances and codes, refer to the Standard for Storage
and Handling of Liqueed Petroleum Gas, ANSI/NFPA
58 and the Propane Installation Code, CAN/CGA
B149.2. This instructs on the safe storage and handling
of propane gases.
Operator’s Manual 3
Contents
Page
Safety ........................................................................ 4
Controls ................................................................... 9
Preparation ............................................................... 10
Installation ................................................................ 12
Operation ................................................................ 13
Troubleshooting ..................................................... 14
Service .................................................................... 16
Storage .................................................................... 19
Specications ......................................................... 20
Wire Diagram ............................................................ 21
Warranty .................................................................. 22
Notes ......................................................................... 23
All information, illustrations and specications in this manual are based on the latest
information available at the time of publication. The right is reserved to make changes at any
time without notice.
4 Operator’s Manual
W
A
R
N
I
N
G
W
A
R
N
I
N
G
S
I
N
T
H
E
M
A
N
U
A
L
S
.
W
A
R
N
I
N
G
S
I
N
T
H
E
M
A
N
U
A
L
S
.
C
A
U
T
I
O
N
O
C
A
U
T
I
O
N
S
I
N
O T
H
E
M
A
N
U
A
L
S
O
C
AU
T
I
O
N
S
I
N
O
T
H
E
M
A
N
U
A
L
S
O
C
A
U
T
I
O
N
S
I
N
O
T
H
E
M
A
N
U
A
L
S
O
C
A
U
T
I
O
N
S
I
N
O
T
H
E
M
A
N
U
A
L
S
Safety
RECOGNIZE SAFETY INFORMATION
This is the safety alert symbol. When you see this
symbol on your machine or in this manual, be alert to
the potential for personal injury.
Follow recommended precautions and safe operating
practices.
UNDERSTAND SIGNAL WORDS
A signal word--DANGER, WARNING or CAUTION--is
used with the safety-alert symbol. DANGER identies
the most serious hazards.
DANGER or WARNING safety signs are located near
specic hazards. General precautions are listed on
CAUTION safety signs. CAUTION also calls attention
to safety messages in this manual.
FOLLOW SAFETY INSTRUCTIONS
Carefully read all safety messages in this manual and on
your machine safety signs. Keep safety signs in good
condition. Replace missing or damaged safety signs.
Be sure new equipment components and repair parts
include the current safety signs. Replacement safety
signs are available from your dealer.
Read this owner’s manual carefully and completely before
trying to assemble, operate, or service this space heater.
Improper use of this space heater can cause serious injury
or death from burns, re, explosion, electrical shock, and
carbon monoxide poisoning.
Make certain you read and understand all warnings.
Keep this manual for reference. It is your guide to safe
and proper operation of this space heater.
If you do no understand any part of this manual and need
assistance, contact your dealer.
Operator’s Manual 5
CARBON MONOXIDE - POISONOUS GAS
DANGER: CARBON MONOXIDE POISONING MAY LEAD TO
DEATH!
Space heaters exhaust contains carbon monoxide - a poisonous gas
that can kill you. You CAN NOT smell or see this gas.
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning
resemble the flu, with headaches, dizziness, and/or nausea. If you have
these signs, the space heater may not be working properly. Get fresh air at
once! Have space heater serviced. Some people are more affected by carbon
monoxide than others. These include pregnant women, persons with heart
or lung disease or anemia, those under the influence of alcohol, and those
at high altitudes.
Never use a space heater in enclosed or partially-enclosed spaces without
proper ventilation. Use only in well-vented areas. Before using space heater,
provide at least a three-square-foot (2800 square cm) opening of fresh,
outside air for each 100,000 Btu / Hr (30 kw) of rating. Space heaters can
produce high levels of carbon monoxide very quickly. When you use a space
heater, remember that you cannot smell or see carbon monoxide. Even if you
can’t smell exhaust fumes, you may still be exposed to carbon monoxide.
If you start to feel sick, dizzy, or weak while using a space heater, get to fresh
air RIGHT AWAY. DO NOT DELAY. The carbon monoxide from space heaters
can rapidly lead to full incapacitation and death.
If you experience serious symptoms, get medical attention immediately.
Inform medical staff that carbon monoxide poisoning is suspected. If you
experienced symptoms while indoors, have someone call the re department
to determine when it is safe to re-enter the building.
NEVER operate the space heater in an explosive atmosphere, near
combustible materials or where ventilation is not sufcient to carry away
exhaust fumes. Exhaust fumes can cause serious injury or death.
NEVER run space heaters inside homes, garages, sheds, or other semi-
enclosed spaces without proper ventilation. These spaces can trap poisonous
gases EVEN IF you run a fan or open doors and windows. Use only in well-
vented areas. Before using space heater, provide at least a three-square-foot
(2800 square cm) opening of fresh, outside air for each 100,000 Btu / Hr (30
kw) of rating.
If you start to feel sick, dizzy, or weak while using the space heater, shut
if off and get fresh air RIGHT AWAY. See a doctor. You may have carbon
monoxide poisoning.
Install battery-operated carbon monoxide alarms or plug-in carbon monoxide
alarms with battery back-up in your home, according to the manufacturer’s
installation instructions. The carbon monoxide alarms should be certied to
the requirements of the latest safety standards for carbon monoxide alarms.
(UL 2034, IAS 6-96, or CSA 6.19.01).
Test your carbon monoxide alarm frequently and replace dead batteries.
6 Operator’s Manual
ELECTRICAL HAZARDS
DANGER- IMPROPER CONNECTION OF THE EQUIPMENT-
GROUNDING CONDUCTOR CAN RESULT IN A RISK OF
ELECTROCUTION. CHECK WITH A QUALIFIED
ELECTRICIAN OR SERVICE PERSON IF YOU ARE IN
DOUBT AS TO WHETHER THE UNIT IS PROPERLY
GROUNDED.
Use only the electrical voltage and frequency specied on model
plate. The electrical connections and grounding of the heater shall
follow the National Electric Code, ANSI/NFPA 70 or the Canadian
Electrical Code, Part 1.
Space heater must be grounded. Use only a properly grounded
three-wire extension cord. Plug into grounded outlet only. If it should
malfunction or breakdown, grounding provides a path of least
resistance for electric current to reduce the risk of electric shock.
The space heater is a potential source of electrical shock if not
kept dry. Keep the space heater dry and do not use in rain or wet
conditions. To protect from moisture, operate it on a dry surface
under an open, canopy-like structure. Dry your hands if wet before
touching the space heater.
Check that the entire cord is free of cuts or tears and that the plug
has all three prongs, especially a grounding pin.
IMPORTANT SAFETY INSTRUCTIONS
Make certain you read and understand all warnings. Keep this
manual for reference. It is your guide to safe and proper operation
of this heater.
1. Use only in areas free of flammable vapors or high dust
content.
2. Minimum heater clearances from combustible materials: Outlet:
8 Ft. (2.44 m), Sides: 2 Ft. (60.96 cm), Top: 6 Ft. (1.83 m), Rear:
2 Ft. (60.96 cm).
3. Locate space heater on a stable and level surface while hot or
operating or a re may occur.
4. Use only in well-vented areas. Before using space heater, provide
at least a three-square-foot (2800 square cm) opening of fresh,
outside air for each 100,000 Btu / Hr (30 kw) of rating.
5. Keep children and animals away from space heater at all times.
6. Use space heater only in accordance with local ordinances and
codes.
7. Keep space heater area clear and free from combustible materials,
gasoline, paint thinner and other flammable vapors and liquids.
8. Never use space heater in living or sleeping areas.
9. Never leave a space heater plugged in without adult supervision
if children or animals are likely to be present. Do not leave heater
unattended.
10. Never move, handle or service a hot or operating heater. Severe
burns may result. You must wait 15 minutes after turning heater
off.
W
A
R
N
I
N
G
W
A
R
N
I
N
G
S
I
N
T
H
E
M
A
N
U
A
L
S
.
W
A
R
N
I
N
G
S
I
N
T
H
E
M
A
N
U
A
L
S
.
C
A
U
T
I
O
N
O
C
A
U
T
I
O
N
S
I
N
O
T
H
E
M
A
N
U
A
L
S
O
C
A
U
T
I
O
N
S
I
N
O
T
H
E
M
A
N
U
A
L
S
O
C
A
U
T
I
O
N
S
I
N
O
T
H
E
M
A
N
U
A
L
S
O
C
A
U
T
I
O
N
S
I
N
O
T
H
E
M
A
N
U
A
L
S
Operator’s Manual 7
IMPORTANT SAFETY INSTRUCTIONS
11. Never attach duct work to front or rear of space heater.
12. Space heaters used in the vicinity of tarpaulins, canvas, or
similar enclosure materials shall be located a safe distance from
such materials. The recommended minimum safe distance is
10 feet (304.8cm). It is further recommended that these enclosure
materials be of a re retardant nature. These enclosure materials
shall be securely fastened to prevent them from igniting or from
upsetting the space heater due to wind action.
13. Unplug space heater when not in use.
14. This product has been approved for use in the Commonwealth
of Massachusetts.
15. Use only the hose and factory preset regulator provided with
the heater.
16. Use only propane gas set up for vapor withdrawal.
17. For indoor use only. Do not use heater outdoors.
18. Do not use heater in basement or below ground level. Propane
gas is heavier than air. If a leak occurs, propane gas will sink
to the lowest possible level.
19. Keep heater at least six feet from propane tank(s). Do
not point heater at propane tank(s) within 20 feet.
20. Keep propane tank(s) below 10 F (37. C).
21. Check heater for damage before each use. Do not use
a damaged heater.
22. Check hose before each use of heater. If highly worn or
cut, replace with hose specied by manufacturer before using
heater.
23. Never block air inlet (rear) or air outlet (front) of heater.
24. Keep heater away from strong drafts, wind, water spray, rain
or dripping water.
25. To prevent injury, wear gloves when handling heater.
26. Do not alter heater. Keep heater in its original state.
27. Do not use heater if altered.
28. Turn off propane supply to heater when not in use.
29. Use only original replacement parts. This heater must
use design-specic parts. Do not substitute or use generic parts.
Improper replacement parts could cause serious or fatal
injuries.
30. This heater is equipped with a thermostat. Heater may start at
anytime!
31. Do not adjust regulator below 7 PSIG or above 20 PSIG.
SAVE THESE INSTRUCTIONS
W
A
R
N
I
N
G
W
A
R
N
I
N
G
S
I
N
T
H
E
M
A
N
U
A
L
S
.
W
A
R
N
I
N
G
S
I
N
T
H
E
M
A
N
U
A
L
S
.
C
A
U
T
I
O
N
O
C
A
U
T
I
O
N
S
I
N
O
T
H
E
M
A
N
U
A
L
S
O
C
A
U
T
I
O
N
S
I
N
O
T
H
E
M
A
N
U
A
L
S
O
C
A
U
T
I
O
N
S
I
N
O
T
H
E
M
A
N
U
A
L
S
O
C
A
U
T
I
O
N
S
I
N
O
T
H
E
M
A
N
U
A
L
S
8 Operator’s Manual
WEAR PROTECTIVE CLOTHING
Wear close tting clothing and safety equipment appropriate
to the job.
Wear a suitable hearing protective device such as
earmuffs or earplugs to protect against objectionable or
uncomfortable loud noises.
Operating equipment safely requires the full attention of
the operator. Do not wear radio or music headphones while
operating machine.
INSPECT SPACE HEATER
Be sure all covers, guards and shields are tight and in
place.
Locate all operating controls and safety labels.
Inspect power cord for damage before using. There is a
hazard of electrical shock from crushing, cutting or heat
damage.
Remove all packing items applied to space heater for
shipment. Remove all items from carton. Check items for
any shipping damage. If space heater is damaged, promptly
inform dealer where you bought space heater.
PREPARE FOR EMERGENCIES
Keep a rst aid kit and re extinguisher handy.
Keep emergency numbers for doctors, ambulance service,
hospital and re department near your telephone.
Be prepared if a re starts.
SERVICE SPACE HEATER SAFELY
Before servicing the space heater, disconnect all equipment
and battery (if equipped) and allow unit to cool down.
Service space heater in a clean dry flat area.
Operator’s Manual 9
Controls
A -- Hot Air Outlet (Front)
B -- Handle
C -- Fan Guard
D -- Power Cord
E -- Hose / Regulator Assembly
F -- Inlet Connector
CONTROLS
SH-375LP
G -- On / Off Switch
H -- Outer Shell
I -- Thermostat Knob
REAR VIEW
A
B
C
D
E
F
G
H
I
10 Operator’s Manual
Preparation
VENTILATION
WARNING: FOLLOW THE MINIMUM FRESH, OUTSIDE
AIR VENTILATION REQUIREMENTS. IF PROPER
FRESH, OUTSIDE AIR VENTILATION IS NOT
PROVIDED, CARBON MONOXIDE POISONING
CAN OCCUR. PROVIDE PROPER FRESH, OUTSIDE
AIR VENTILATION BEFORE RUNNING HEATER.
Provide a fresh air opening of at least three square feet for
each 100,000 Btu/Hr rating. Provide extra fresh air if more
heaters are being used.
PROPANE SUPPLY
Propane / L.P. gas and Propane / L.P. tank(s) are to be
furnished by the user.
Use this heater only with a propane vapor withdrawal
supply system. See Chapter 5 of the Standard for Storage
and Handling of Liqueed Petroleum Gas, ANSI/NFPA 58
and the Propane Installation Code CAN/CGA B149.2. Your
local library or re department will have this booklet.
The amount of Propane / L.P. gas ready for use from
Propane / L.P. tanks varies. Two factors decide this amount:
1. The amount of Propane / L.P. gas in tank(s)
2. The temperature of tank(s)
The chart below shows the number of 100 pound (45
kg) tanks needed to run this heater. Do not operate this
product with any tanks smaller than 100 pounds.
Less gas is vaporized at lower temperatures. You may
need two or more 100 pound (45 kg) tanks or one larger
tank in colder weather. Your local propane gas dealer will
help you select the proper supply system. The minimum
surrounding air temperature rating for each heater is
-20° F (-29° C).
Temperature at Tank # of Tanks
40°F (5°C) and above 3
Below 40°F (5°C)
(Use larger tank)
Preparation
Operator’s Manual 11
THEORY OF OPERATION
The Fuel System: The hose / regulator assembly attaches to the propane gas supply. The propane gas moves
through the solenoid valve and out the nozzle.
The Air System: The motor turns the fan. The fan pushes air into and around the combustion chamber. This air
is heated and provides a stream of clean, hot air.
The Ignition System: The direct spark ignitor (DSI) sends voltage to the ignitor. The ignitor ignites the fuel and
air mixture.
The Safety Control System: This system causes the heater to shut down if the flame goes out. The motor will
continue to run, but no heat is produced.
Air For Combustion Air For Heating
Cool
Air In
(Back)
Motor
Nozzle
Power Cord
Hose/
Regulator
Assembly
Solenoid Valve
Ignitor
Combustion Chamber
DSI
Fan
Clean
Heated
Air Out
(Front)
12 Operator’s Manual
Installation
INSTALLATION
IMPORTANT: Review and understand the warnings in
the Safety Information section. They are needed to safely
operate this space heater. Follow all local ordinances and
codes when using this space heater.
WARNING: TEST ALL GAS PIPING AND
CONNECTIONS FOR LEAKS AFTER
INSTALLING OR SERVICING. NEVER
USE AN OPEN FLAME TO CHECK FOR
A LEAK. APPLY A MIXTURE OF LIQUID
SOAP AND WATER TO ALL JOINTS.
BUBBLES FORMING SHOW A LEAK.
CORRECT ALL LEAKS AT ONCE.
1. Provide Propane / L.P. supply system (see Propane / L.P.
Supply section).
2. Connect POL tting on hose / regulator assembly to
Propane / L.P. tank(s). Turn POL tting counterclockwise
into threads on tank. Tighten rmly using wrench.
IMPORTANT: Tighten regulator with black adjustment
knob pointing down. Pointing adjustment knob down
protects regulator from weather damage.
3. Connect hose to inlet connector. Tighten rmly using a
wrench. (Fig. 2)
IMPORTANT: Extra hose or piping may be used if needed.
Install extra hose or piping between hose/regulator
assembly and Propane / L.P. tank. You must use the
regulator supplied with heater.
4. Open propane supply valve on Propane / L.P. tank(s)
slowly.
Note: If not opened slowly, excess-ow check valve on
Propane / L.P. tank will stop gas ow. If this happens,
you may hear a click inside the regulator assembly. To
reset the excess ow check valve, close Propane / L.P.
supply valve and open again slowly.
5. Adjust regulator between 7 and 20 PSIG.
Note: Higher regulator setting will allow heater to produce
more heat.
6. Check all connections for leaks.
7. Close Propane / L.P. supply valve.
WARNING: DO NOT ADJUST REGULATOR
BELOW 7 PSIG OR ABOVE 20 PSIG.
HEATER MAY NOT RUN PROPERLY.
Propane/LP
Tank
Supply
Valve
Hose
POL Fitting
Regulator
Adjustment Knob
(pointing down)
(Fig. 1)
Hose
Inlet Connector
(Fig. 2)
Operator’s Manual 13
Operation
OPERATION
WARNING: FOLLOW THE MINIMUM FRESH,
OUTSIDE AIR VENTILATION REQUIREMENTS.
IF PROPER FRESH, OUTSIDE AIR VENTILATION
IS NOT PROVIDED, CARBON MONOXIDE
POISONING CAN OCCUR. PROVIDE PROPER
FRESH, OUTSIDE AIR VENTILATION BEFORE
RUNNING HEATER.
START SPACE HEATER:
1.
Follow all ventilation and safety information.
2. Place the space heater in an area that provides maximum
circulation of the heated air. Follow all location requirements
noted in the Safety Information.
3. Locate heater on stable and level surface. Make sure strong
drafts do not blow into front or rear of heater.
4. Plug power cord of heater into a three-prong, grounded
extension cord. Extension cord must be at least 6 feet (1.83
m) long, UL listed and of a proper size. See Extension Cord
Chart.
5. Plug extension cord into a 120 volt/60 hertz, 3-hole, grounded
outlet.
6. Open propane supply valve on Propane / L.P. tank(s) slowly.
Note: If not opened slowly, excess-flow check valve on
Propane / L.P. tank will stop gas ow. If this happens, you may
hear a click inside the regulator assembly. To reset the excess-
ow check valve,close Propane / L.P. supply valve and open
again slowly.
7. Make sure regulator is set between 7 and 20 psig.
Note: Higher regulator setting will allow heater to produce more
heat.
8. Turn on/off switch to the ON position. Adjust thermostat to
desired setting. If heater does not start, thermostat setting may
be too low. Turn thermostat knob to higher position to start
heater.
Note: If heater does not start, turn on/off switch to the OFF position.
Wait ten seconds for safety control to reset, then try again.
STOP SPACE HEATER:
1. Tightly close Propane / L.P. supply valve on propane
tank(s).
2. Wait a few seconds. Heater will burn gas left in supply
hoses.
3. Turn ON/OFF switch to the OFF position.
4. Unplug heater.
TO RESTART HEATER:
If safety control stops gas flow to heater, motor will continue to
run.
1. Turn on/off switch to the OFF position.
2. Wait ten seconds, then turn on/off switch to the ON position.
If heater does not restart:
1. Check manual valves (if any) and supply valves (on Propane
/ L.P. tank). Make sure they are open.
2. Check fuel level in Propane / L.P. tank(s). If fuel level is too
low, contact local Propane / L.P. gas company.
If heater still does not restart, contact your local service center.
Extension Cord Size Requirement
Length of Cord: Rated Cord:
Up to 50 feet (15 m)
18 AWG
51 to 100 feet (15.5 to 30.48 m)
16 AWG
101 to 200 feet (30.78 to 60.96 m) 14 AWG
14 Operator’s Manual
Symptom Problem Solution
Fan does not turn when heater
is plugged in.
Heater will not ignite.
No electrical power to heater.
Fan hitting inside of heater shell.
Fan blades bent.
Defective motor.
User did not follow installation or
operation instructions properly.
No spark at ignitor. To test for spark,
see "Service: Ignitor" and follow
step 8. If you see spark at ignitor,
have heater serviced by qualied
service person. If no spark seen:
a. Loose or disconnected ignitor
wire
b. Wrong spark gap
c. Bad ignitor electrode
d. Bad spark transformer
Check voltage to electrical outlet. If volt-
age is good, check heater power cord
for breaks.
Adjust motor / fan mount to keep fan
from hitting inside of heater shell.
Replace fan.
Replace motor.
Repeat installation and operation
instructions.
a. Check ignitor wire. Tighten or reattach
loose ignitor wire. See "Maintenance:
Spark Transformer" for ignitor wire
location
b. Set gap between ignitor electrode and
nozzle to .13"/.15" (3.3/3.8 mm)
c. Replace ignitor electrode. See
"Maintenance: Ignitor".
d. Replace spark transformer. See
"Maintenance: Spark Transformer".
Troubleshooting
WARNING: HIGH VOLTAGE. NEVER SERVICE SPACE HEATER WHILE IT IS PLUGGED IN,
OPERATING, OR HOT. SEVERE BURNS AND ELECTRICAL SHOCK CAN OCCUR.
Troubleshooting
Operator’s Manual 15
Symptom Problem Solution
Heater shuts down while
running.
Heater producing odor.
Propane supply may be inadequate.
High surrounding air temperature
causing thermal limit device to shut
down heater.
Restricted air flow.
Damaged fan.
Excessive dust or debris in
surrounding area.
Gas leak
Heater not operating on a 100 lb.
propane / L.P. cylinder. Insufcient
propane / L.P. gas will result in odor.
Propane / L.P.... supply tank is
"freezing up". Evaporation and
consumption rate of propane from
supply tank is to great for the size of
the tank and air temperature
a. Rell tank
b. Provide additional and/or larger
tanks. See "Preparation: Propane
Supply".
This can happen when running heater
in temperatures above 85° F (30° C).
Run heater in cooler temperatures.
Check heater inlet and outlet. Re-
move any obstructions.
Replace fan. See "Maintenance:
Fan".
Clean heater. See "Maintenance".
Check all connections for leaks. Apply
mixture of liquid soap and water to
gas joints. Bubbles forming show a
leak that must be corrected
To obtain correct mixture of propane
/ L.P. gas and air, use a larger cylin-
der size, i.e. 100 lb. (minimum) See
"Preparation: Propane Supply".
a. Use a larger supply cylinder size,
i.e. 100 lb. (minimum).
b. Reduce consumption rate by
operating the heater at LOW
setting temporarily until frost
disappears from the tank
WARNING: HIGH VOLTAGE. NEVER SERVICE SPACE HEATER WHILE IT IS PLUGGED IN,
OPERATING, OR HOT. SEVERE BURNS AND ELECTRICAL SHOCK CAN OCCUR.
WARNING: Use only in areas free
of high dust content.
16 Operator’s Manual
Service
MAINTENANCE:
WARNING: TO AVOID RISK OF BURN AND
ELECTRICAL SHOCK, NEVER ATTEMPT
TO SERVICE SPACE HEATER WHILE IT IS
PLUGGED IN, OPERATING, OR HOT.
KEEP HEATER CLEAR AND FREE FROM
COMBUSTIBLE MATERIALS, GASOLINE AND
OTHER FLAMMABLE VAPORS AND LIQUIDS
DO NOT BLOCK THE FLOW OF COMBUSTION
OR VENTILATION AIR.
1. Keep heater clean. Clean heater annually or as
needed to remove dust and debris. If heater is dirty or
dusty, clean heater with a damp cloth. Use household
cleaners on difcult spots.
2. Inspect heater before each use. Check connections
for leaks. Apply mixture of liquid soap and water to
connections. Bubbles forming show a leak. Correct
all leaks at once.
3. Inspect hose / regulator assembly before each use. If
hose is highly worn or cut, replace with hose specied
by manufacturer.
4. Have heater inspected yearly by a qualied service
agency.
5. Keep inside of heater free from combustible and
foreign objects. Remove motor and other internal
parts if needed to clean inside of heater.
6. Clean fan blades each season or as needed.
Service
Operator’s Manual 17
MAINTENANCE (CONTINUED):
(Fig. 3)
(Fig. 4)
(Fig. 5)
WARNING: NEVER SERVICE HEATER WHILE
IT IS PLUGGED IN, CONNECTED TO
PROPANE SUPPLY, OPERATING OR
HOT. SEVERE BURNS AND ELECTRICAL
SHOCK CAN OCCUR.
CLEANING FAN:
Clean fan every 500 hours of operation or as needed.
1. Remove screws on side cover using 5/16" nut-driver.
2. Remove side cover.
3. Detach the ve motor wires from parts under heater
shell. Be sure to detach only wires coming from motor.
(Fig. 3)
The ve motor wires are:
• white wire—to terminal board
• black wire—to terminal board
• blue wire—to thermal switch wire
• orange wire—to solenoid valve
• green wire—to grounding screw on shell
4. Remove fan guard from rear of heater.
5. Reach into rear of heater shell. Carefully pull motor wires
through hole in bottom of shell. (Fig. 4)
Note: Pull wires through hole one at a time.
6. Remove nuts and mounting bolts holding motor mount
to shell. Use 3/8" nut-driver and 7/16" wrench.
7. Carefully pull motor and fan out of shell.
IMPORTANT: Be careful not to damage fan. Do not set
motor and fan down with the weight resting on fan. This
could damage fan pitch.
8. Turn motor and fan around. Place motor and fan into
shell backwards.
Note: Motor will go into shell rst (Fig. 5).
9. Line up rear mounting holes in shell with rst hole on
each side of motor mount (Fig. 5).
Note: When holes are lined up, fan should be outside of
shell.
10. Holding mounting bolt, carefully reach through fan
blades into rear of heater. Be careful not to damage
fan pitch. Insert bolt through motor mount and shell.
With free hand, attach nut, nger tight. Repeat process
for other mounting hole.
11. Use 1/8" hex wrench to loosen setscrew which holds
fan to motor shaft (Fig. 6).
12. Slip fan off motor shaft.
13. Clean fan using soft cloth moistened with kerosene or
solvent.
T
erminal
Board
Grounding Screw
Thermal
Switch Wire
Solenoid
Valve
Rear
Mounting
Hole
First
Hole
Motor
Shaft
Fan
Setscrew
(Fig. 6)
Service
18 Operator’s Manual
CLEANING FAN (CONT.):
14. Dry fan thoroughly.
15. Replace fan on motor shaft. Make sure setscrew is
touching back of flat surface on motor shaft (Fig. 7).
16. Place setscrew on flat of shaft. Tighten setscrew rmly
(40-50 inch-pounds).
17. Remove two nuts and bolts securing motor mount to
shell.
18. Pull motor and fan from shell. Turn motor and fan
around. Carefully place back in shell. Note: Fan will
go into shell rst.
19. Line up mounting holes in shell with holes on motor
mount. Replace four bolts through shell and motor
mount. Insert bolts from outside of heater. Tighten nuts
rmly.
20. Route motor wires through hole in bottom of shell
(Fig. 4).
21. Connect motor wires as follows (Fig. 3):
• white wire—to terminal board
Note: Attach to empty connector on white wire side of
terminal board.
• black wire—to terminal board
Note: Attach to empty connector on black wire side of
terminal board.
• blue wire—to thermal switch wire
• orange wire—to solenoid valve
• green wire—to grounding screw on shell
22. Replace side cover.
23. Replace fan guard.
(Fig. 7)
Fan
Hub
Setscrew
Motor
Shaft
Operator’s Manual 19
STORAGE
CAUTION: DISCONNECT HEATER FROM
PROPANE / L.P. SUPPLY TANK(S).
1. Store Propane / L.P. tank(s) in safe manner. See
Chapter 5 of Standard for Storage and Handling of
Liqueed Petroleum Gases, ANSI/NFPA 58 and the
Propane Installation Code CAN/CGA B149.2. Follow
all local codes. Always store propane tanks outdoors.
2. Place plastic cover caps over brass ttings on inlet
connector and hose / regulator assembly.
3. Store in dry, clean and safe place. Do not store
hose / regulator assembly inside heater combustion
chamber.
4. When taking heater out of storage, always check
inside of heater. Insects and small animals may place
foreign objects in heater. Keep inside of heater free
from combustible and foreign objects.
Storage
20 Operator’s Manual
ITEM SPECIFICATION
Model Size SH-375LP
Output Rating (BTU / Hr) 225,000 to 375,000
Fuel Propane / L.P. Vapor Only
Fuel Consumption:
(Gal. Per Hr / Liters Per Hr) Min: 2.5 / 9.4
Max: 4.0 / 15
(Pounds Per Hr / Kilograms Per Hr) Min: 10.4 / 4.7
Max: 17.4 / 7.9
Supply Pressure to Regulator:
Minimum (for input adjustment) 25 PSIG / 172kPa
Maximum Tank Pressure
Regulator Outlet Pressure 7-20 PSIG / 48 to 138 kPa
Hot Air Output (Approx.) 1500 CFM / 42.5 cubic meter / minute
Motor RPM 1725
Motor HP 1/5
Electric Input 120V / 60Hz
Amperage (Normal Run) 4.2
Ignition Electronic Direct Spark, D.S.I.
Shipping Weight
(Approximate Pounds /
Kilograms) 48 / 21.8
Space Heater Weight
(Approximate Pounds /
Kilograms) 41 / 18.6
Specications
RECORD SERIAL NUMBER
Write you model number, machine serial number and
date of purchase in the spaces provided below. Your
dealer needs this information when ordering parts.
Model No. ______________________________________________
Machine Serial No. _______________________________________
Date of Purchase ________________________________________
(To be lled in by purchaser)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72

Sunbelt SPL375000 Le manuel du propriétaire

Taper
Le manuel du propriétaire
Ce manuel convient également à