Ubiquiti Loco5AC Mode d'emploi

Taper
Mode d'emploi
NanoStation loco Zip Tie
Package Contents
Installation Requirements
Shielded Category 5 (or above) cabling with drain wire should be used for all
outdoor wired Ethernet connections and should be grounded through the AC
ground of the PoE.
We recommend that you protect your networks from harmful outdoor
environments and destructive ESD events with industrial-grade, shielded Ethernet
cable from Ubiquiti. For more details, visit ui.com/toughcable
Surge protection should be used for all outdoor installations. We recommend that
you use two Ethernet Surge Protectors, model ETH-SP, one near the NanoStation
loco and the other at the entry point to the building. The ETH-SP will absorb
power surges and safely discharge them into the ground.
Loco5AC Quick Start Guide
Power LED
Ethernet Port
Diagram Showing Use of Ethernet Surge Protectors
Hardware Overview
Port View
The Power LED will light blue when the device is connected to a power source.
Loco5AC Quick Start Guide
Reset Button
10/100/1000 Ethernet port used to connect the power and should be connected
to the LAN and DHCP server.
To reset to factory defaults, press and hold the Reset button for more than 10
seconds while the device is powered on.
Hardware Installation
1.
2.
Pole Mount
1.
Loco5AC Quick Start Guide
2.
3.
Loco5AC Quick Start Guide
Connecting Power
WARNING: The switch port must comply with the power specifications
listed in this “Specifications”.
Accessing airOS via Wi-Fi
Loco5AC Quick Start Guide
Verify connectivity in the airOS® Configuration Interface using the UISP™ app or
Web Portal. Both are available for 15 minutes immediately after you power on the
device. If necessary, you can power cycle the device to re-enable its Wi-Fi.
UISP App
1. Download the UISP app.
2. Connect your device’s Wi-Fi to the SSID named: <model>:<MAC Address>
3. Launch the app and follow the on-screen instructions.
Web Portal
1. Connect your device’s Wi-Fi to the SSID named: <model>:<MAC Address>
2. Launch your web browser and go to: http://setup.ui.com
3. Select your Country and Language. You must agree to the Terms of Use to use
the product. Click Continue.
4. Create a username and password. Confirm your new password and then click
Save.
The airOS Configuration Interface will appear, allowing you to customize your
settings as needed. For additional details, refer to the User Guide available at
ui.com/download/airmax-ac
Installer Compliance Responsibility
Devices must be professionally installed and it is the professional installer’s
responsibility to make sure the device is operated within local country regulatory
requirements.
The Output Power field is provided to the professional installer to assist in meeting
regulatory requirements.
Note: Ensure that DHCP is enabled on your Wi-Fi adapter.
Note: Ensure that your Wi-Fi connection has DHCP enabled.
Loco5AC Quick Start Guide
Specifications
Loco5AC
Dimensions 179 x 77.5 x 59.1 mm
(7.05 x 3.05 x 2.33")
Weight 180 g (6.35 oz)
Processor MIPS 74K
Memory DDR2 64 MB
Antenna Gain 13 dBi
Networking Interface (1) 10/100/1000 Ethernet Port
Power Method Passive PoE 2-Pair (Pairs 4, 5+; 7, 8 Return)
Power Supply 24V, 0.3A Gigabit PoE Supply*
Max. Power Consumption 7W
Supported Voltage Range 24V ±10%
ESD/EMP Protection ±24kV Contact / Air
Operating Temperature -40 to 70° C (-40 to 158° F)
Operating Humidity 5 to 95% Noncondensing
Certifications CE, FCC, IC
* Not included. Recommended PoE Adapter: POE-24-12W-G.
Operating Frequency (MHz)
Worldwide 5150 - 5875
US/CA U-NII-1 5150 - 5250
U-NII-2A 5250 - 5350
U-NII-2C 5470 - 5725
U-NII-3 5725 - 5850
Management Radio (MHz)
Worldwide 2412 - 2472
US/CA 2412 - 2462
Safety Notices
1. Read, follow, and keep these instructions.
2. Heed all warnings.
3. Only use attachments/accessories specified by the manufacturer.
WARNING: Do not use this product in location that can be submerged by water.
Loco5AC Quick Start Guide
WARNING: Avoid using this product during an electrical storm. There may be a remote
risk of electric shock from lightning.
Electrical Safety Information
1. Compliance is required with respect to voltage, frequency, and current requirements
indicated on the manufacturer’s label. Connection to a different power source than those
specified may result in improper operation, damage to the equipment or pose a fire hazard if
the limitations are not followed.
2. There are no operator serviceable parts inside this equipment. Service should be provided
only by a qualified service technician.
Limited Warranty
ui.com/support/warranty
The limited warranty requires the use of arbitration to resolve disputes on an individual basis,
and, where applicable, specify arbitration instead of jury trials or class actions.
Compliance
FCC
Changes or modifications not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions.
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause
undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operations of this equipment in a residential area is likely
to cause harmful interference in which case the user will be required to correct the interference
at his own expense.
This radio transmitter has been approved by FCC.
ISED Canada
CAN ICES-3(A)/NMB-3(A)
This device complies with ISED Canada licence-exempt RSS standard(s). Operation is subject
to the following two conditions:
1. This device may not cause interference, and
2. This device must accept any interference, including interference that may cause undesired
operation of the device.
This radio transmitter has been approved by ISED Canada.
Loco5AC Quick Start Guide
The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the
potential for harmful interference to co-channel mobile satellite systems.
CAN ICES-3(A)/NMB-3(A)
Le présent appareil est conforme aux CNR d’ISDE Canada applicables aux appareils radio
exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :
1. l’appareil ne doit pas produire de brouillage;
2. l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
Le présent émetteur radio a été approuvé par ISDE Canada.
Les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés uniquement pour une
utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de
satellites mobiles utilisant les mêmes canaux.
IMPORTANT NOTE
Radiation Exposure Statement
This equipment complies with radiation exposure limits set forth for an uncontrolled
environment.
This equipment should be installed and operated with minimum distance 25 cm between the
radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
AVIS IMPORTANT
Déclaration sur l’exposition aux rayonnements
Cet équipement est conforme aux limites prévues pour l’exposition aux rayonnements dans
un environnement non contrôlé.
Lors de l’installation et de la mise en fonctionnement de l’équipement, assurez-vous qu’il y
ait une distance minimale de 25 cm entre l’élément rayonnant et vous.
Cet émetteur ne doit être installé à proximité d’aucune autre antenne ni d’aucun autre
émetteur, et ne doit être utilisé conjointement à aucun autre de ces appareils.
Australia and New Zealand
Warning: This equipment is compliant with Class A of CISPR 32. In a residential
environment this equipment may cause radio interference.
Brazil
Nota: Este equipamento não tem direito à proteção contra interferência prejudicial e
não pode causar interferência em sistemas devidamente autorizados.
CE Marking
Loco5AC Quick Start Guide
CE marking on this product represents the product is in compliance with all directives that are
applicable to it.
Country List
AT BE BG CY CZ DE DK EE EL ES FI FR HR HU
IE IT LV LT LU MT NL PL PT RO SE SI SK UK
BFWA (Broadband Fixed Wireless Access) members noted in blue
Note: This device meets Max. TX power limit per ETSI regulations.
The following apply to products that operate in the 5 GHz frequency range:
Note: This device is restricted to indoor use only when operating in the 5150 - 5350
MHz frequency range within all member states.
Note: Operation in the 5.8 GHz frequency band is prohibited in BFWA member states.
Other countries listed may use the 5.8 GHz frequency band.
WEEE Compliance Statement
Declaration of Conformity
Online Resources
© 2022 Ubiquiti Inc. All rights reserved.
Loco5AC Quick Start Guide
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Ubiquiti Loco5AC Mode d'emploi

Taper
Mode d'emploi

dans d''autres langues