Prepare Electrical Wiring
Electrical Requirements
Acceptable for use in dry, damp and wet locations.
The grounding and bonding of the LED Driver shall be
done in accordance with National Electric Code (NEC)
Article 600.
Follow all National Electric Codes (NEC) and local codes.
These products are only suitable for connection to a circuit from a
Class 2 power source.
These products have not been evaluated for use when connected
to a power source that does not comply with Class 2 voltage and
energy limited supplies.
Save These Instructions
Use only in the manner intended by the
manufacturer. If you have any questions, contact the
manufacturer.
EN Instruction Guide
FOR UL ONLY
EN
2424
Volt
For the latest North American install guides for your product go to: https://products.LED.com/sign-lighting/tetra-powermax
For the latest European install guides for your product go to: https://products.LED.com/eu
BG Българската версия на инструкциите за инсталаця и
информация за безопасност могат да бъдат намерени
на следния адрес: https://products.LED.com/eu
CS Návod k montáží a bezpečnostní informace v češtině
najdete zde: https://products.LED.com/eu
DA Den danske version af installationsvejledningen og
sikkerhedsoplysninger kan ndes på følgende placering:
https://products.LED.com/eu
DE Die deutsche Version der Installationsanleitung und
Sicherheitsinformationen nden Sie in folgendem Verzeic:
https://products.LED.com/eu
EL Μπορείτε να βρείτε την ελληνική εκδχή των οδηγιών
νγκατάστασης και των πληροφοριών ασφάλειας στην
εξής τοποθεσία: https://products.LED.com/eu
ES La versión española de las instrucciones de instalación y
la información sobre seguridad puede encontrarse en la
siguiente ubicación: https://products.LED.com/eu
ET Eestikeelse paigaldusjuhendi ja ohutusnñuded leiate
aadressilt: https://products.LED.com/eu
FI Asennusohjeiden ja turvallisuustietojen suomenkielinen
versio löytyy seuraavasta paikasta: https://products.LED.
com/eu
FR La version française des instructions d’installations
et information de sécurité est disponible à l’adresse
suivante: https://products.LED.com/eu
HR Hrvatska verzija priručnika za ugradnju i sigurnosnih
informacija nalazi se na sljedečoj lokaciji: https://products.
LED.com/eu
HU A telepítési útmutató és a biztnosági információk magyar
nyelvű változata az alábbi címen található: https://
products.LED.com/eu
IT La versione italiana del manuale di installazione e
sicurezza può essere reperita nella seguente sezione:
https://products.LED.com/eu
LT Lietuvišką diegimo instrukcijos ir saugos informacijos
versiją galima rasti šioje vietoje: https://products.LED.
com/eu
LV Uzstādīšanas instrukciju un drošības informāciju latviešu
valodā var atrast šeit: https://products.LED.com/eu
NL De Nederlandse versie van de installatie-instructies en
veiligheidsinformatie kan op de volgende locatie worden
gevonden: https://products.LED.com/eu
PL Polską wersję instrukcji instalacji oraz informacje
dotyczące bezpieczeństwa można znaleźć w następującej
lokalizacji: https://products.LED.com/eu
PT A versão em Português das instruções de instalação e
das informações de segurança pode ser encontrada na
seguinte localização: https://products.LED.com/eu
RO Versiunea în limba română a instrucţiunilor de instalare
şi a informaţiilor de siguranţă pot  găsite la: https://
products.LED.com/eu
SV Ni hittar den svenska versionen av
installationsanvisningarna och säkerhetsinformationen på
följande plats: https://products.LED.com/eu
SL Previdnostna opozorila in varnostne informacije so na
zadnji strani vodnika za namestitev. Pred začetkom
namestitve izdelka jih skrbno preberite: https://products.
LED.com/eu
SK Slovenskú verziu montažnej príručky a bezpečnostnŷch
instrukcií nájdete na nasledujúcej lokalite: https://
products.LED.com/eu
BEFORE YOU BEGIN
Read these instructions completely and carefully.
EN
GEPMH2471-W1CS1
GEPMH2465-W1CS1
GEPMH2457-W1CS1
GEPMH2450-W1CS1
GEPMH2441-W1CS1
GEPMH2432-W1CS1
GEPMH2471-W1B
Current Lighting Solutions, LLC
Beachwood, OH 44122
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks
of the General Electric Company and are used under license. Information provided is subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 1 of 6
Rev 08/28/23
SIGN168-Tetra-LED-Signage-PowerMax-Installation-Guide_R02
PowerMAX / Snap SS
LED Lighting System
Installation Guide
SIGN168 | GE2031-4480
EN
WARNING / AVERTISSEMENT
RISK OF ELECTRIC SHOCK
Turn power o before inspection, installation or removal.
Properly ground power supply enclosure.
RISK OF FIRE
Use only suitably approved wire for input/output
connections. Minimum size 18 AWG (0.82mm2)
Follow all local codes.
Not to be submerged or used in a marine environment.
RISQUES DE DÉCHARGES ÉLECTRIQUES
Coupez l’alimentation avant l’inspection, l’installation ou le déplacement.
Assurez-vous de correctement mettre à terre l’alimentation électrique.
RISQUES D’INCENDIE
N’utilisez que des ls approuvés par UL pour les entrées/sorties de connexion. Taille
minimum 18 AWG (0.82mm2)
Respectez tous les codes locaux.
Ne pas submerger ou installer dans un environnement marin.
UL WARNING / AVERTISSEMENT UL
RISK OF FIRE OR ELECTRIC SHOCK
LED Retrot Kit installation requires knowledge of
sign electrical systems. If not qualied, do not attempt
installation. Contact a qualied electrician.
Install this kit only in host signs that have been identied in
the installation instructions and where the input rating of
the retrot kit does not exceed the input rating of the sign.
Installation of this LED retrot kit may involve drilling or
punching of holes into the structure of the sign. Check
for enclosed wiring and components to avoid damage to
wiring and electrical parts.
Do not make or alter any open holes in an enclosure of
wiring or electrical components during kit installation.
RISQUE D’INCENDIE OU DE CHOC ÉLECTRIQUE
L’installation de l’équipement de remplacement DEL exige Ia connaissance des
systèmes électriques pour enseignes. Si non qualié, ne tentez pas d’installation.
Veuillez contacter un électricien qualié.
Risque d’incendie ou de choc électrique. Installez cet ensemble seulement dans des
enseignes hôtes qui ont été identiés dans les instructions d’installation et dont la
capacité d’entrée de l’ensemble ne dépasse pas la capacité d’entrée de l’enseigne.
Linstallation de cet équipement de remplacement DEL peut impliquer le perçage ou le
poinçonnage de trous dans la structure du panneau Vériez le câblage et les composants
inclus pour éviter d’endommager le câblage et les composants électriques.
Ne pas faire ou modier les trous ouverts dans une enceinte de câblage ou de
composants électriques pendant l’installation de cet équipement de remplacement DEL.
TC Measure Point
UL approved 18 AWG (0.82 mm2) supply wire
UL approved 22-14 AWG (0.33-2.08 mm2) wire connectors or
22-18 AWG (0.33-0.82 mm2) in-line/IDC connectors
#6 (M3) screws, 1/8 inch (3.2 mm) rivets, or electrical grade RTV
silicone or equivalent
Weather box GEXNWB2 (optional)
24 Volt Power Supply
Tetra® PowerMAX / Snap SS LED modules
Electrical grade RTV silicone:
Momentive RTV 6700 Series Silicone Rubber Adhesive Sealant
Momentive White Blanc RTV 162 Silicone Rubber Adhesive
Sealant-Electrical Grade
Dow Corning 3140 - Non-Corrosive Flowable (clear)
Dow Corning 3145 - Non-Corrosive Nonowable (clear or gray)
Dow Corning RTV 748 Non-Corrosive Sealant-White
1
12
2
3
3
4
4
5
5
6
67
7
Components
Tips
For optimal light uniformity in halo-lit applications the Tetra® LED modules should be mounted on UL recognized plastic
and the light output from the Tetra® LED system should be directed back into the sign enclosure. This will allow for uniform
backlighting of the sign and will provide simple mounting for the Tetra® LED system.
A best practice for the supply wire at the point at which it is brought into the sign is to have a drip loop on the inside of the
letter to keep water from collecting on the Tetra® LED strip.
These products are not required to be enclosed or protected from weather.
Tetra® PowerMAX / Snap SS Installation Guide
Current Lighting Solutions, LLC
Beachwood, OH 44122
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks
of the General Electric Company and are used under license. Information provided is subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 2 of 6
Rev 08/28/23
SIGN168-Tetra-LED-Signage-PowerMax-Installation-Guide_R02
Components - Tetra® SNAP Accessories (optional)
Tetra SNAP Rail (GEDSRL08-3)
Tetra Snap SS Plastic Clip (GESSPC-3)
Tetra Snap SS Metal Clip (GESSMC-3)
Tetra SNAP Frame Endcap (GEDSFE-3)
Tetra SNAP Socket Endcap (GEDSSE-3)
Tetra SNAP Dual Rail Socket Cap (GESSDR-3)
Tetra SNAP T-connector (GEDSTC-3)
Tetra SNAP Interconnector (GEDSIC-3)
Tetra PowerMAX is also compatible with the following Tetra SNAP Rail components.
See https://products.LED.com/led-signage-lighting for further details and install instructions.
1
12
2
3
3
4
4
5
56
6
7
8
8
7
Measure and cut Tetra LED strip
to the appropriate length for
each letter. Cuts can be made
between any of the modules.
Use rivets, screws, or electrical
grade RTV silicone to secure
at least every fth LED module
within the channel letter. Use #6
(M3) pan headed metal screws,
1/8-inch (3.2 mm) rivets, or
electrical grade RTV silicone.
Before you begin, clean surfaces
and remove all debris from the
inside of the channel letter.Clean
the surfaces with a 50:50 mixture
of isopropyl alcohol (IPA) and
water and let dry.
Layout Modules
Drill a 1/4-inch (6.4 mm) hole
near the LED strip and grommet
the hole for supply wire access.
Remove all the debris from the
inside of the channel letter and
replace the sign face.
NOTE: For halo-lit applications LED modules should be mounted on UL
recognized clear acrylic or polycarbonate. The light output from the LED
system should be directed back into the sign enclosure. This will allow for
uniform backlighting of the sign and will provide simple mounting.
Remove tape backing and stick LED
modules into place. When using
tape apply approximately 15 psi
pressure on the module (avoid the
lens dome surface) for 5 seconds,
full bonding strength after 24 hours.
Continue until you have reached the
end of the strip.
Do not
press lens
1
4
2
5
3
6
Tetra® PowerMAX / Snap SS Installation Guide
Current Lighting Solutions, LLC
Beachwood, OH 44122
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks
of the General Electric Company and are used under license. Information provided is subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 3 of 6
Rev 08/28/23
SIGN168-Tetra-LED-Signage-PowerMax-Installation-Guide_R02
Electrical Connections
Cap wires Optional: Cut wires ush
Connect LED strips using in-line (IDC) connectors or
twist-on wire connectors.
Seal all connections in wet locations with electrical
grade RTV silicone.
Must cap all exposed wires with appropriate wire
connectors and seal with electrical grade RTV silicone.
Optional: Cut wires ush to the module and seal with
electrical grade RTV silicone.
Red stripe (+)
White (-)
Seal all connections in wet locations
with electrical grade RTV silicone
NOTE: Do not use connectors pre-lled with silicone grease/mineral base protective grease or use silicone grease to seal connections.
1 2
To LED
power
supply
Red (+)
Black or
blue (-)
Red Stripe (+)
Run a wire from the LED power supply to the LED
module and connect.
NOTE: Must be used with Class 2 24 Volt Power
Supplies.
NOTE: Refer to Maximum Loading & Remote
Mounting Specications on page 4.
Connect the red stripe wire (+) of the LED strip to the
red wire (+) of the power supply. Connect the white
wire (-) of the LED strip to the black or blue wire (-) of
the LED power supply.
NOTE: All electrical connections should be suitably
protected from mechanical damage and the
environment. Seal all connections in wet locations
with electrical grade RTV silicone.
LED
Power
Supply
To Tetra LED System
Red (+)
Black or blue (-)
White (-)
Seal all connections in wet locations
with electrical grade RTV silicone
OPTIONAL
A Weather Box (GEXNWB2) may be used to
house and seal Class 2 connections.
A) Insert wire connectors into weather box. Fill
with electrical grade silicone and close box.
B) Secure the weather box using a #6 or #8
(M2 or M3) screw.
Weather box
can be painted
Light engine
3
AB
4
Dismantling
At the end of life, the contained LED light source may be cut out using suitable wire cutters, removed from the mounting surface,
then replaced per the cutting and installation instructions above, or dismantled and taken to a communal collecting point for
environmentally friendly disposal in accordance with local regulations by a professional installer.
Tetra® PowerMAX / Snap SS Installation Guide
Current Lighting Solutions, LLC
Beachwood, OH 44122
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks
of the General Electric Company and are used under license. Information provided is subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 4 of 6
Rev 08/28/23
SIGN168-Tetra-LED-Signage-PowerMax-Installation-Guide_R02
1. (Existing Signs Only) Prior to installation, survey the site for information regarding power and accessibility inside and outside the
building. Ensure that the branch circuit supplying the existing transformer or ballast will be within the voltage ratings of the new LED
power supply, and have a current rating not exceeding 20A, or that permitted by applicable local, state, or country electrical codes
(whichever is less).
2. (Existing Signs Only) Remove the existing lighting equipment to be replaced, such as neon tubing or uorescent tubes; and
associated transformers and ballasts. Care should be taken not to break the existing neon or uorescent tubes. NOTE: Follow all
federal and local regulations when disposing of neon tubing, uorescent tubes, transformers and ballasts.
3. (Existing Signs Only) If removal of the existing lighting equipment eliminates the disconnect switch, as required by applicable
local, state, or country electrical codes; a new disconnect switch must be installed.
4. (Existing Signs Only) Repair and seal any unused openings in the electrical enclosure. Openings greater than 12.7-mm (1/2-in)
diameter require a metal patch secured by screws or rivets and caulked with non-hardening caulk. Smaller openings may be sealed
with non-hardening caulk.
5. (Existing Signs Only) A clean and dry mounting surface ensures optimum adhesion if the self-adhesive method of mounting is
chosen. Follow the manufacturer’s directions when using a non-oil based solvent, such as rubbing alcohol to clean the surface area
where you intend to mount the module. Before installing, ensure the surface is dry.
6. Using the layout guidelines above, determine required number of LED modules required to illuminate the sign.
7. A 24VDC Class 2 Power Supply, as listed below, must be used with this retrot kit. Using the Maximum Loading chart below,
determine the number of Power Supplies required to power the number of LED modules required to illuminate the sign, so as not to
overload the Power Supply chosen.
8. Follow the instructions above to properly mount the LED modules.
9. Connect the DC output of the power supply to the LED modules using the Electrical Connections instructions above.
10. Connect the power unit to the supply in accordance with the applicable local, state, and country electrical codes, and the instructions
found in the power supply installation guide.
11. If required, the disconnect switch shall be installed by qualied personnel, in accordance with applicable local, state, and country
electrical codes.
FOR UL ONLY
Retrot Instructions
Troubleshooting
Symptom Solution
All letters are OFF Check AC input connection and/or check circuit breaker.
Check wire connection(s) at the Tetra® LED System and power supply for improper termination(s) or short
circuits. Properly terminate or replace the wire connection(s).
Check that connections are the red striped wire (+) of the LED strip to the red wire (+) of the power supply
and the white wire (-) of the LED strip to the black or blue wire (-) of the power supply.
Some LEDs
appear dim Ensure the overall length of the Tetra® LED System does not exceed the maximum load.
Ensure the length of supply wire is equal to or below the recommended remote mounting distance.
Ensure the overall length of the Tetra® LED System does not exceed the maximum load.
Some of the letters are
not illuminated Check wire connection(s) at the Tetra® LED System and power supply for improper termination(s) or short
circuits. Properly terminate or replace the wire connection(s).
Check that connections are the red striped wire (+) of the LED strip to the red wire (+) of the power
supply and the white wire (-) of the LED strip to the black or blue wire (-) of the power supply.
Shadows Re-route supply wire and secure to the back of the can with electrical grade RTV silicone. Adjust wire connector
orientation so that it does not cover any LEDs.
Adjust LED layout to ensure uniformity of illumination on the face of the letter.
Power Supply
Wattage
18 AWG/0.82 mm2
Supply Wire
16 AWG/1.31 mm2
Supply Wire
14 AWG/2.08 mm2
Supply Wire
12 AWG/3.31 mm2
Supply Wire
25W 120 ft./36.6 m
60W, 80W, 100W,
180W, 200W, 300W 20 ft./6.1 m 25 ft./7.6 m 35 ft./10.6 m 40 ft./12.1 m
Maximum Remote Mounting Distance
Tetra® PowerMAX / Snap SS Installation Guide
Current Lighting Solutions, LLC
Beachwood, OH 44122
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks
of the General Electric Company and are used under license. Information provided is subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 5 of 6
Rev 08/28/23
SIGN168-Tetra-LED-Signage-PowerMax-Installation-Guide_R02
Tetra® PowerMAX / Snap SS Installation Guide
Maximum Loading per 24V DC Power Supply
Power Supply
GEPM2471-W1
GEPM2465-W1
GEPM2457-W1
GEPM2450-W1
GEPM2441-W1
GEPM2432-W1
GEPMH2471-W1CS1
GEPMH2465-W1CS1
GEPMH2457-W1CS1
GEPMH2450-W1CS1
GEPMH2441-W1CS1
GEPMH2432-W1CS1 GEPMH2471-W1B
GEPMH2471-W1X
GEPMH2465-W1X
GEPMH2457-W1X
GEPMH2450-W1X
GEPMH2441-W1X
GEPMH2432-W1X
Rating per module 24V DC
35mA/module
0.84W/module
24V DC,
50mA/module
1.2W/module
24V DC,
50mA/module
1.2W/module
24V DC,
54mA/module
1.3W/module
GEPS24-25U-NA
Load shall not exceed 1.04A 25 modules/
17 ft. (5.18 m) 17 modules/
34 ft. (10 m) 17 modules/
11.3 ft. (3.4 m) 17 modules/
11.3 ft. (3.4 m)
GEPS24D-60U-GLX
*GELP24-60U-GL
Load shall not exceed 2.5A
65 modules/
43 ft. (13.20 m) 45 modules/
30 ft. (9.14 m) 45 modules/
30 ft. (9.14 m) 42 modules/
28 ft. (8.53 m)
GEPS24D-80U
GEPS24W-80
Load shall not exceed 3.3A
80 modules/
53 ft. (16.15 m) 54 modules/
108 ft. (33 m) 54 modules/
36 ft. (11 m) 52 modules/
34.7 ft. (10.6 m)
GEPS24-100U-GLX
GEPS24D-100U-NA
GEPS24LT-100U-NA
USVI-100024FBA
USVI-100024FE
Load shall not exceed 4.0A
96 modules/
64 ft. (19.5 m) 64 modules/
128 ft. (39 m) 64 modules/
42.6 ft. (13 m) 64 modules/
42.6 ft. (13 m)
GEPS24-180U
Load shall not exceed 3.8A per
each (of 2) output channels
90 modules/
60 ft. (18.29 m) per bank
180 modules/
120 ft. (36.58 m) per PS
60 modules/
120 ft. (36.5 m) per bank
120 modules/
240 ft. (73 m) per PS
60 modules/
40 ft. (12.2 m) per bank
120 modules/
80 ft. (24.4 m) per PS
60 modules/
40 ft. (12.2 m) per bank
120 modules/
80 ft. (24.4 m) per PS
GEPS24-300U-GL
Load shall not exceed 4.0A per
each (of 3) output channels
96 modules/
64 ft. (19.5 m) per bank
288 modules/
192 ft. (58.5 m) per PS
64 modules/
128 ft. (39 m) per bank
192 modules/
384 ft. (117 m) per PS
64 modules/
42.6 ft. (13 m) per bank
192 modules/
127.8 ft. (39 m) per PS
64 modules/
42.6 ft. (13 m) per bank
192 modules/
128.1 ft. (39 m) per PS
GEPS24-100U-GLX2/TT
**GEPS24V50-100W
Load shall not exceed 4.0A
103 modules/
68.67 ft. (20.9 m) 72 modules/
72 ft. (21.9 m) 72 modules/
48 ft. (14.6 m) 66 modules/
47.1 ft. (14.3 m)
GEPS24-200U-GLX2
Load shall not exceed 4.0A per
each (of 2) output channels
103 modules/
68.6 ft. (20.9 m) per bank
206 modules/
137.3 ft. (41.8 m) per PS
72 modules/
72 ft. (21.9 m) per bank
144 modules/
144 ft. (43.9 m) per PS
72 modules/
48 ft. (14.6 m) per bank
144 modules/
96 ft. (29.2 m) per PS
66 modules/
47.1 ft. (14.3 m) per bank
132 modules/
94.2 ft. (28.7 m) per PS
GEPS24-300U-GLX2
Load shall not exceed 4.0A per
each (of 3) output channels
103 modules/
68.6 ft. (20.9 m) per bank
309 modules/
206 ft. (62.8 m) per PS
72 modules/
72 ft. (21.9 m) per bank
216 modules/
216 ft. (65.8 m) per PS
72 modules/
48 ft. (14.6 m) per bank
216 modules/
144 ft. (43.8 m) per PS
66 modules/
47.1 ft. (14.3 m) per bank
198 modules/
141.4 ft. (43.1 m) per PS
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference
to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to
correct the interference at his own expense.
This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005 du Canada.
Electrical products must not be thrown out with domestic waste. They must be taken to a communal collecting point for environmentally friendly
disposal in accordance with local regulations. Contact your local authorities or stockist for advice on recycling. The packaging material is recyclable.
Dispose of the packaging in an environmentally friendly manner and make it available for the recyclable material collection-service.
This product is intended solely for sign use only. Not intended for general lighting applications.
Conforms to the following standards:
*GELP24-60U-GL minimum load = 24 modules / 16 ft. (4.87 m) for GEPM24xx-W1, 17 modules / 11 ft. (3.45 m) for GEPMH24xx-W1CS1 and GEPMH24xx-
W1B, or 16 modules / 10 ft. (3.25 m) for GEPMH24xx-W1X.
**GEPS24V50-100W minimum load = 60 modules / 40 ft. (12.19 m) for GEPM24xx-W1, 42 modules / 21 ft. (6.40 m) for GEPMH24xx-W1CS1 and
GEPMH24xx- W1B, or 39 modules / 26 ft. (7.92 m) for GEPMH24xx-W1X.
Current Lighting Solutions, LLC
Beachwood, OH 44122
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks
of the General Electric Company and are used under license. Information provided is subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 6 of 6
Rev 08/28/23
SIGN168-Tetra-LED-Signage-PowerMax-Installation-Guide_R02
Any changes or modications not expressly
approved by the party responsible for
compliance could void the user’s authority
to operate this equipment.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Tetra PowerMAX and Snap SS LED Signage Guide d'installation

Taper
Guide d'installation