Zephyr ZMLE42CG Manuel utilisateur

Catégorie
Hottes
Taper
Manuel utilisateur
WWW.ZEPHYRONLINE.COM
NOV20.0101
Airow Control Technology
TM
C
Milano Island
ZML-M90CG, ZML-M90CS,
ZML-E42CG, ZML-E42CS
EN Use, Care, and Installation Guide
FR Guide d’utilisation, d’entretien et d’installation
2
Milano Island Use, Care, and Installation Guide
MILANO
ISLAND
CORE
3
Milano Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Contents
Page
Safety Information ............................................................................ 4-6
Types of Safety Warnings ................................................................... 4
General Safety ..................................................................................4-5
Operation ........................................................................................... 6
Electrical Requirements ...................................................................... 6
Federal Communication Commission Interface Statement ................. 6
List of Materials ................................................................................... 7
Installation Instructions .................................................................... 8-20
Ducting Calculation Sheet .................................................................. 8
Mounting Height, Clearance, & Ducting ...........................................9-10
Ducting Options .................................................................................11
Hood Specifications ............................................................................12
Electrical Supply .................................................................................13
Cable Lock .........................................................................................13
Mounting the Hood .......................................................................... 14-18
Ductless Recirculation .....................................................................19-20
Features & Controls ..........................................................................21-27
Proximity Controls ...........................................................................21-23
Zephyr Connect ..............................................................................24-25
Optional RF Remote Control ............................................................26-27
Maintenance ................................................................................... 28-30
Hood & Filter Cleaning .....................................................................28-29
LumiLight LED ................................................................................... 30
ACT™ Conversion .............................................................................31-32
Airflow Control Technology (ACT™) ....................................................31
Enabling ACT™ .................................................................................. 32
Wiring Diagram ..................................................................................33
Troubleshooting............................................................................... 34-36
List of Parts & Accessories .................................................................. 37
Notes ..................................................................................................38
Limited Warranty ...............................................................................39
Product Registration ...........................................................................40
4
Milano Island Use, Care, and Installation Guide
MILANO
ISLAND
CORE
Safety Information
Your safety and the safety of others are very important.
We have provided many important safety messages in this
manual for your appliance. Always read and obey all safety
messages.
This is the Safety Alert Symbol. This symbol alerts you to
potential hazards that can cause severe bodily injury or death.
All safety messages will follow the Safety Alert Symbol and either
the words “DANGER” “WARNING” or “CAUTION
DANGER
Danger means that failure to heed this safety statement may
result in severe injury or death.
READ AND SAVE THESE INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the manufacturer.
b) Before servicing or cleaning unit, switch power o at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
General Safety
WARNING
Warning means that failure to heed this safety statement
may result in extensive product damage, serious personal
injury, or death.
CAUTION
Caution means that failure to heed this safety statement
may result in minor or moderate personal injury, property or
equipment damage.
WARNING
To reduce the risk of fire or electric shock, do not use this fan
with any solid-state control device.
WARNING
CAUTION
For General Ventilating Use Only. Do Not Use To Exhaust
Hazardous Or Explosive Materials And Vapors. Take care
when using cleaning agents or detergents. Suitable for use in
household cooking area.
WARNING
WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE
FIRE:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may ignite.
Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or
when flambeing food. (i.e. Crepes Suzette, Cherries Jubilee,
Peppercorn Beef Flambe’).
c) Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate for
the size of the surface element.
5
Milano Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Safety Information
WARNING
READ AND SAVE THESE INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS
IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn o the burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE AND
CALL THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN – You may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels – a
violent steam explosion will result.
d) Use an extinguisher ONLY if:
1) You know you have a Class ABC extinguisher, and you
already know how to operate it.
2) The fire is small and contained in the area where it
started.
3) The fire department is being called.
4) You can fight the fire with your back to an exit
Based on “Kitchen Firesafety Tips” published by NFPA.
WARNING
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
CAUTION
To reduce risk of fire and to properly exhaust air outside, do
not vent exhaust air into spaces within walls, ceilings, attics,
crawl spaces, or garages.
WARNING
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes and
standards, including fire-rated construction.
b) Sucient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel burning
equipment to prevent back drafting. Follow the heating
equipment manufacturer’s guideline and safety standards such
as those published by the National Fire Protection Association
(NFPA), and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and the local code
authorities.
c) When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected
to a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit.
WARNING
Prop. 65 Warning for California Residents: This product may
contain chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
6
Milano Island Use, Care, and Installation Guide
MILANO
ISLAND
CORE
Safety Information
Operation
Ź Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and
loose clothing.
Ź The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation,
maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to negligence and
the warranty of the unit automatically expires due to improper maintenance.
NOTE: Please check www.zephyronline.com for revisions before doing any custom work.
Electrical Requirements
Important:
Ź Observe all governing codes and ordinances.
Ź It is the customer’s responsibility to be aware of these below:
Ź To contact a qualified electrical installer.
Ź To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 latest
edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and all local codes
and ordinances.
Ź If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path
is adequate.
Ź Do not ground to a gas pipe.
Ź Check with a qualified electrician if you are not sure the range hood is properly grounded.
Ź Do not have a fuse in the neutral or ground circuit.
Ź This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected
by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to Electrical Diagram
on product.
Ź A cable locking connector (not supplied) might also be required by local codes. Check with local requirements, purchase and
install appropriate connector if necessary.
* National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575
Federal Communication Commission Interface Statement
Ź This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Ź This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one of the following
measures:
Ź Reorient or relocate the receiving antenna.
Ź Increase the separation between the equipment and receiver.
Ź Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
Ź Consult the dealer or an experienced radio/TV technician for help.
READ AND SAVE THESE INSTRUCTIONS
7
Milano Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
List of Materials
(3) Wire Nuts
(4) #6 x 1-1/2”
wood screws
(20) M4 x 8 pan-head
machine screws
(1) M4 x 12
safety screw
1 - Hardware package
1 - Top support frame
1 - Bottom support frame
2 - Top duct covers
2 - Bottom duct covers
1 - Hood body w/ blower (pre-installed)
1 - Canopy, glass or stainless
2 - Aluminum mesh filters
4 - LumiLight LED, 6W (pre-installed)
1 - 8” round damper (pre-installed)
(4) 3/16 x 1/4 pan-head
machine screws
A
B
Front of Hood
C
L
/
Cut-Out Shaded Area
1 - Paper ceiling
template
(4) ø12 OD / ø5
ID Washers
1 - Square support frame bracket
2 - Lateral support brackets
(4) 3/16 x 1/4 screws
Parts Not Supplied
Ducting, conduit and all installation tools
Cable locking connector (if required by local codes)
Duct cover extension accessory
Recirculating kit
RF remote control
Parts Supplied
8
Milano Island Use, Care, and Installation Guide
MILANO
ISLAND
CORE
Duct pieces
To t al
Equivalent number
length x used =
3- 1/ 4” x 10”
Rect.,
straight
1 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect. to
6” round
transition
5 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect. to
6” round
transition
90
0
elbow
20 Ft. x ( ) =
Ft.
6”, 7”, 8”, 10”
Round,
90
0
15 Ft.
x ( ) =
Ft.
6”, 7”, 8”, 10”
Round,
45
0
9 Ft. x ( ) =
Ft.
Ft.
6”, 7”, 8”, 10”
Round,
straight
1 Ft. x ( ) =
Ft.
Subtotal column 1 =
Duct pieces
To t al
Equivalent number
length x used =
6”, 7”, 8”, 10”
Round, wall
cap with
damper
30 Ft. x ( ) =
Ft.
Ft.
Ft.
Ft.
6”, 7”, 8”, 10”
Round
roof cap
30 Ft. x ( ) =
Ft.
Subtotal column 2 =
Subtotal column 1 =
Total ductwork =
Maximum Duct Length: For satisfactory air movement,
the total duct length
should not exceed 150 equivalent feet.
6” round to
3- 1/ 4” x 10”
rect.
transition
1 Ft. x ( ) =
Ft.
6” round to
3- 1/ 4” x 10”
rect.
transition
90
0
elbow
16 Ft. x ( ) =
Ft.
7” round to
3 1/ 4” x 10”
rect.
transition
8 Ft. x ( ) =
Ft.
7” round to
3- 1/ 4” x 10”
rect.
transition
90
0
elbow
23 Ft. x ( ) =
Ft.
elbow
elbow
7” to 6” or
8” to 7” Round
tapered
reducer
25 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect. 90
0
elbow
15 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect. 45
0
elbow
9 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect. 90
0
flat elbow
24 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect.
wall cap
with damper
30 Ft. x ( ) =
Ft.
Ft. x ( ) =
Ft.
15
6”, 7“, 8”
Round
in-line
damper
Ducting Calculation Sheet
Installation Instructions
9
Milano Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Mounting Height, Clearance, & Ducting
min. A
min. B
max. C
Standard Extension
Hood Heights Duct Cover Duct Cover
minimum ducted (A) 28-1/2” 44-1/2“
minimum recirculating (B) 32-1/2” 49“
maximum (C) 50” 82”
Ceiling Heights
minimum ducted (D)
88-1/2” (7’ 4-1/2”) 104-1/2“ (8‘8-1/2”)
minimum recirculating (E) 92-1/2” (7’ 8-1/2”) 109“ (9’ 1”)
maximum (F) 120” (10’) 152” (12’ 8”)
36”
24” min.
34” max.
min. D
min. E
max. F
10
Milano Island Use, Care, and Installation Guide
MILANO
ISLAND
CORE
Mounting Height, Clearance, & Ducting
A minimum of 8” round duct is recommended to maintain maximum air flow eciency.
Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%.
Also use the ducting calculation sheet (on page 11) to compute total available duct run when using
elbows, transitions and caps.
ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required,
increase duct size from 8” to 10”.
If turns or transitions are required; install as far away from hood duct output and as far apart,
between the two as possible.
Minimum mount height between range top to hood bottom should be no less than 24”.
Maximum mount height should be no higher than 34”.
It is important to install the hood at the proper mounting height. Hoods mounted too low could result
in heat damage and fire hazard; while hoods mounted too high will be hard to reach and will lose its
performance and eciency.
If available, also refer range manufacturer’s height clearance requirements and recommended hood
mounting height above range. Always check your local codes for any dierences.
Duct cover extension kit available for ceiling heights up to 12 feet. Turn to the list of parts and
accessories section for part number and ordering information.
For shipment and installation damages:
Ź Please fully inspect unit for damage before installation.
Ź If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or
replacement.
Ź If the unit is damaged by the customer, repair or replacement is the responsibility of the customer.
Ź If the unit is damaged by the installer (if other than the customer), repair of replacement must be
made by arrangement between customer and installer.
Installation Instructions
11
Milano Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Ducting Options
Ź Use single wall rigid metal ductwork only.
Ź Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct
Tape.
Fire Hazard: NEVER exhaust air or terminate ductwork into
spaces between walls, crawl spaces, ceilings, attics, or garages.
All exhaust must be ducted to the outside, unless using the
recirculating option.
WARNING
Sot or crawl space
roof pitch w/
flashing & cap
(blower
housing)
(blower
housing)
(blower
housing)
side wall cap
w/ gravity
damper
ductless
recirculating
12
Milano Island Use, Care, and Installation Guide
MILANO
ISLAND
CORE
Ů
FRONT
SIDE
TOP of HOOD
TOP SUPPORT FRAME
(top view)
C/L
9-11/16”
10-9/16”
4-13/16
5/8”
7-3/4”
1-1/4”3-1/6
AC In
3/8”
C/L
C/L
12-15/16
(36”) 35 3/16” or (42“) 41-15/16”
23-15/16
STANDARD
min. ducted - 28-1/2”
min. recirc. - 32-1/2”
max. - 50”
Z1C-03ML
min. ducted - 44-1/2”
min. recirc. - 49”
max. - 82”
12-3/4”
25-9/16
10-15/16
5-5/16”
14-1/8”
11-1/4”
7-15/16”
Installation Instructions
13
Milano Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Electrical Supply
Electrical wiring must be done by qualified person(s) in
accordance with all applicable codes and standards. Turn o
electrical power at service entrance before wiring.
WARNING
For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not
use extension cord or adapter plug with this appliance.
Follow national electrical codes or prevailing local codes and ordinances.
This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly
grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring
must be 2 wire w/ ground. Please also refer to the Electrical Diagram labeled on product.
Cable Lock
A cable locking connector (not supplied) might be required by local codes. Check with local
requirements and codes, purchase and install appropriate connector if necessary. (FIG. A)
Cable Lock
FIG. A
14
Milano Island Use, Care, and Installation Guide
MILANO
ISLAND
CORE
Mounting the Hood
Ceiling Preparation
1. Determine hood mounting location and
temporarily tape paper template (included with
the hood) to the ceiling.
2. Cut-out internal shaded area of template
to allow the ducting and electrical to pass
through.
3. Add wood blocking (min. 2” x 4”) onto ceiling
joists to reinforce ceiling above the drywall.
(FIG. C1).
4. Secure (2) 1-1/2” wood screws into points A
and B of the paper template (FIG. B). Do not
completely tighten screws, leave approximately
1/4” exposed.
Hood Preparation
5. Remove screws securing top and bottom
support frames together.
6. Adjust support frame to accommodate the
desired hood height and re-assemble the frame
using the previously removed screws (2 screws
for each support frame arm). (FIG. C2).
3
1
2
Ceiling Joists
Wood Blocking
Top Support Frame
Bottom Support Frame
front
Hood Body/Canopy
4
6
5
FIG. C
Hood is intended to be mounted to a finished
ceiling.
CAUTION
A
B
Cut-Out Shaded Area
FIG. B
Installation Instructions
Front of Hood
15
Milano Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Mounting the Hood
FIG. D
16
Milano Island Use, Care, and Installation Guide
MILANO
ISLAND
CORE
7. Hood heights between 40” to 50” require lateral support brackets to be installed to the two top
support frame cut o arms and their corresponding bottom support frame arms. Install lateral
support brackets by (12) M4 x 8 sheet metal screws shown in FIG. D.
8. Hood heights between 45” to 50” require a square support bracket to be installed inside the
support frame. Install square support bracket to top support frame arms by (8) M4 x 8 sheet metal
screws. (FIG. E1) Top support frame arms extend past lower support frame bracket with shorter
hood heights. (FIG. E2).
9. Lift support frame assembly up to the ceiling making sure the word “front” on the top support
frame faces the front of the hood where the controls will be located (FIG. F). The key-holes on the
top support frame should cover the wood screws previously installed in the ceiling. Slide support
frame towards narrow end of key-holes to lock the frame in place.
10. Install the last (2) #6 x 1-1/2” wood screws with washers into the two remaining corners of the top
support frame to secure it to the ceiling. Tighten all screws.
Mounting the Hood
FRONT
FRONT
FIG. E
FIG. F
12
Installation Instructions
17
Milano Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Mounting the Hood
FIG. G
FIG. H
11. Remove tape securing electronics mounting bracket to hood. Remove (2) screws from top of hood
body and set screws aside. Position electronics mounting brackets and secure to hood body using
the (2) previously removed screws (FIG. G).
12. Lift aluminum mesh filters from hood. Place canopy over blower housing located on top of hood
and secure it to hood body using (4) 3/16 x 1/4 pan-head machine screws through the filter
opening (FIG. H).
13. Lift hood body and align the (4) pre-installed mounting screws on top of blower housing (FIG. C5
on Page 14) with the (4) key holes on the bottom of the support frame. (FIG. I) Slide hood towards
the narrow end of key holes to lock in place. Hand tighten each of the (4) screws to secure hood
to bottom of support frame. Install (1) M4 x 12mm safety screw into bottom support frame to
further secure the hood. (FIG. I). Reinstall aluminum mesh filters.
BLOWER
HOUSING
FIG. I
18
Milano Island Use, Care, and Installation Guide
MILANO
ISLAND
CORE
14. Install electrical and duct work. Seal duct work with aluminum duct tape.
15. Unwrap the blue antenna wire and position it behind the duct cover from steps 17-18. There is no
need to secure it.
16. Power up hood, verify all functions and check for leaks around duct tape.
17. Assemble top duct covers (with louver holes) together over top support frame, secure top duct
covers together by magnetic strips.
NOTE: If using hood in ductless recirculating mode you must install the air diverter plate to the top
support frame prior to assembling the duct covers. Turn to page 19 for more details.
18. Secure top duct covers to top support frame by using (4) 3/16 x 1/4 screws (2 screws for each top
duct cover). (FIG. J1).
19. Assemble bottom duct covers together over top duct covers and secure together by magnetic
strips. Bottom duct covers should rest on top of the hood body.
Mounting the Hood
1
Top Duct Covers
Top Support Frame
Bottom Duct Covers
Bottom Support Frame
FIG. J
Installation Instructions
19
Milano Island Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Ductless Recirculation
Ductless recirculation is intended for applications where an exhaust duct work is not possible to be
installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood.
Fumes and exhaust from cooking are drawn and filtered by a set of optional charcoal filters. The air is
then purified and re-circulated back within the home.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new
duct work, if possible. The hood is most eective and ecient as an exhaust hood. Only when the
exhaust option is not possible should you recourse to converting the hood into a recirculating hood.
When converted to be a recirculating hood, a set of charcoal filters are required on top of its standard
Metal Filter set. Order according to its part number below. The standard mesh filters are intended to
capture residue from cooking, and the optional charcoal filters help to purify fumes exhausted from
cooking for recirculation.
Recirculating Kit Installation (required if no ducting is used)
Kit includes the charcoal filters and the air diverter plate.
Hood Model Part Number Filters in Package
ZML-M90CS ZRC-00ML 2
ZML-M90CG ZRC-00ML 2
ZML-E42CS ZRC-00ML 2
ZML-E42CG ZRC-00ML 2
1. Purchase recirculating kit per the part number above.
2. Secure air diverter plate to wall below duct cover bracket. (FIG. K) Run 8” ducting from top of
hood and secure to air diverter plate. See manual included with recirculating kit for more detailed
instructions.
3. Remove aluminum mesh filter from hood. Install charcoal filter bracket inside filter opening. Note:
screws to secure charcoal filter bracket are already pre-installed in the hood and must first be
removed. Clip charcoal filters onto charcoal filter bracket. (FIG. K)
20
Milano Island Use, Care, and Installation Guide
MILANO
ISLAND
CORE
Installation Instructions
4. Re-Install aluminum mesh filter.
5. Enable recirculating mode on the proximity
controls. (Refer details to pg. 20)
6. Charcoal filters must be replaced after every
200 hours of use (or approximately every 3 to 6
months based on the average of 1 - 2 hours of
daily cooking time). After 200 hours of use, the
notification bell icon will display. When the bell
is tapped, the LCD display will cycle between
showing “REPLACE CHARCOAL FILTER” and
“HOLD UP TO RESET” every 2 seconds.
Charcoal Filter Replacements
Hood Model Part Number
Quantity to
Order
ZML-M90CS Z0F-C002 2
ZML-M90CG Z0F-C002 2
ZML-E42CS Z0F-C002 2
ZML-E42CG Z0F-C002 2
DO NOT WASH CHARCOAL FILTERS. Charcoal
filters may need to be changed more often
depending on cooking habits.
FIG. K
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80

Zephyr ZMLE42CG Manuel utilisateur

Catégorie
Hottes
Taper
Manuel utilisateur

dans d''autres langues