IMPORTANT
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors or liquids in the vicinity
of this or any other appliance.
AVERTISSEMENT
Ne pas entreposer ni utiliser de l'essence ni d'autres vapeurs ou liquides inflamĆ
mables dans le voisinage de cet appariel, ni de tout autre appareil.
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS
MUST BE POSTED IN A PROMINENT LOCATION. THIS INFORMATION MAY BE
OBTAINED BY CONTACTING YOUR LOCAL GAS SUPPLIER.
LES INSTRUCTIONS À RESPECTER AU CAS OÙ L'UTILISATEUR PERÇOIT UNE
ODEUR DE GAZ DOIVENT ÊTRE AFFICHÉES DANS UN ENDROIT BIEN VISIBLE.
VOUS POUVEZ VOUS LES PROCURER AUPRÈS DE VOTRE FOURNISSEUR DE
GAZ LOCAL.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR
MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE
INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING THIS EQUIPMENT
AVERTISSEMENT: UNE INSTALLATION, UN AJUSTEMENT, UNE ALTÉRATION, UN
SERVICE OU UN ENTRETIEN NON CONFORME AUX NORMES PEUT CAUSER DES
DOMMAGES À LA PROPRTE, DES BLESSURES OU LA MORT. LISEZ ATTENTIVEĆ
MENT LES DIRECTIVES D'INSTALLATION, D'OPÉRATION ET D'ENTRETIEN AVANT
DE FAIRE L'INSTALLATION OU L'ENTRETIEN DE CET ÉQUIPEMENT.
The information contained in this manual is important for the proper installation,
use, and maintenance of this oven. Adherence to these procedures and instrucĆ
tions will result in satisfactory baking results and long, trouble free service.
Please read this manual carefully and retain it for future reference.
Les informations données dans le présent manuel sont importantes pour installer,
utiliser et entretenir correctement ce four. Le respect de ces instructions et proĆ
dures permettra d'obtenir de bons résultats de cuisson et une longue durée de serĆ
vice sans problèmes. Veuillez lire le présent manuel et le conserver pour pouvoir
vous y reporter à l'avenir.
Errors: Descriptive, typographic or pictorial errors are subject to correction. SpecificaĆ
tions are subject to change without notice.
Erreurs:Les erreurs de description, de typographie ou d'illustration font l'objet de
corrections. Les caractéristiques sont sujettes à modifications sans préavis.
THE REPUTATION YOU CAN COUNT ON
UNE RÉPUTATION SUR LAQUELLE VOUS POUVEZ COMPTER
For over a century and a half, The Blodgett Oven Company has been building
ovens and nothing but ovens. We've set the industry's quality standard for all
kinds of ovens for every foodservice operation regardless of size, application
or budget. In fact, no one offers more models, sizes, and oven applications
than Blodgett; gas and electric, fullĆsize, halfĆsize, countertop and deck, conĆ
vection, Cook'n Hold, CombiĆOvens and the industry's highest quality Pizza
Oven line. For more information on the full line of Blodgett ovens contact your
Blodgett representative.
Cela fait maintenant dessus un siècle et demi que Blodgett se spécialise dans
la fabrication de fours. Nous avons établi les normes de qualité qui s'appliĆ
quent dans l'industrie à tous les types de fours utilisés dans les services aliĆ
mentaires, quel qu'en soit la taille, l'exploitation ou le budget. En fait, ni n'offre
plus de modèles, de tailles et d'applications de fours que Blodgett. À gaz et
électriques. De tailles différentes, sur plan de travail et superposables. Qu'il
s'agisse de fours à convection, des modèles Cook'n Hold et CombiĆOven, ou
de la gamme de fours à pizzas de la plus haute qualité offerte sur le marché.
Pour de plus amples informations sur la gamme complète de fours Blodgett,
veuillez contacter votre représentant Blodgett.
Your Service Agency's Address:
Adresse de votre agence de service:
Model/Modèl:
Serial Number/Numéro de série:
Your oven was installed by/
Installateur de votre four:
Your oven's installation was checked by/
Contrôleur de l'installation de votre four:
Table of Contents/Table des Matières
Introduction
Oven Description and Specifications 2. . . .
Oven Components 3. . . . . . . . . . . . . . . . . . . .
Installation
Delivery and Location 4. . . . . . . . . . . . . . . . .
Stand Assembly 5. . . . . . . . . . . . . . . . . . . . . .
Oven Assembly 7. . . . . . . . . . . . . . . . . . . . . .
Oven Assembly to Stand 7. . . . . . . . . . . . .
Leg Attachment 8. . . . . . . . . . . . . . . . . . . . .
Oven Leveling 8. . . . . . . . . . . . . . . . . . . . . .
Ventilation 9. . . . . . . . . . . . . . . . . . . . . . . . . . .
Canopy Type Exhaust Hood 9. . . . . . . . . .
Direct Flue Arrangement 10. . . . . . . . . . . . .
Utility Connections - Standards and
Codes 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Gas Connection 12. . . . . . . . . . . . . . . . . . . . . .
Electrical Connection 15. . . . . . . . . . . . . . . . .
Initial Startup 16. . . . . . . . . . . . . . . . . . . . . . . . .
Operation
Safety Information 17. . . . . . . . . . . . . . . . . . . .
Solid State Manual Control 18. . . . . . . . . . . . .
Solid State Digital Control 19. . . . . . . . . . . . . .
Pulse Plus 21. . . . . . . . . . . . . . . . . . . . . . . . . . .
Cook and Hold Control 22. . . . . . . . . . . . . . . .
CHĆPro3 (Solid State Programmable
Digital Control) 24. . . . . . . . . . . . . . . . . . . . . . .
Blodgett IQ2T Vision Control 27. . . . . . . . . .
How Cook and Hold Works 37. . . . . . . . . . . .
General Guidelines for Operating
Personnel 38. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Suggested Times and Temperatures 39. . . .
Maintenance
Cleaning and Preventative Maintenance 40.
Troubleshooting Guide 41. . . . . . . . . . . . . . . .
Introduction
Description et Spécifications du Four 42. . . .
Éléments du Four 43. . . . . . . . . . . . . . . . . . . . .
Installation
Livraison et Implantation 44. . . . . . . . . . . . . . .
Montage du bâti 45. . . . . . . . . . . . . . . . . . . . . .
Montage du Four 47. . . . . . . . . . . . . . . . . . . . .
Assemblage du Four sur le Socle 47. . . . .
Pose des Pieds 48. . . . . . . . . . . . . . . . . . . . .
Mise à Niveau du Four 48. . . . . . . . . . . . . . .
Ventilation 49. . . . . . . . . . . . . . . . . . . . . . . . . . .
Hotte D'évacuation Type Voûte 49. . . . . . .
En Prise Directe 50. . . . . . . . . . . . . . . . . . . . .
Branchements de Service -
Normes et Codes 51. . . . . . . . . . . . . . . . . . . . .
Branchement de Gaz 52. . . . . . . . . . . . . . . . .
Raccordement Électrique 55. . . . . . . . . . . . . .
Mise en Marche Initiale 56. . . . . . . . . . . . . . . .
Utilisation
Informations de Sécurité 57. . . . . . . . . . . . . . .
Commandes à SemiĆConducteurs 58. . . . . .
Commandes Numériques à
SemiĆConducteurs 59. . . . . . . . . . . . . . . . . . . .
Pulse Plus 62. . . . . . . . . . . . . . . . . . . . . . . . . . .
Commande Cuisson et Maintien 63. . . . . . . .
CHĆPro3 (Commande Numérique
Programmable pour SemiĆConducteurs) 65.
Blodgett IQ2T Commande Vision 69. . . . . .
Principe de la Fonction de Cuisso
et Maintien 80. . . . . . . . . . . . . . . . . . . . . . . . . . .
Consignes Générales à l'Intention
des Utilasateurs 81. . . . . . . . . . . . . . . . . . . . . .
Durées et Températures Suggérées 82. . . . .
Entretien
Nettoyage et Entretien Préventif 83. . . . . . . .
Guide de Détection des Pannes 84. . . . . . . .
Introduction
2
Oven Description and Specifications
Cooking in a convection oven differs from cooking
in a conventional deck or range oven since heated
air is constantly recirculated over the product by
a fan in an enclosed chamber. The moving air conĆ
tinually strips away the layer of cool air surroundĆ
ing the product, quickly allowing the heat to peneĆ
trate. The result is a high quality product, cooked
at a lower temperature in a shorter amount of time.
Blodgett convection ovens represent the latest adĆ
vancement in energy efficiency, reliability, and
ease of operation. Heat normally lost, is recircuĆ
lated within the cooking chamber before being
vented from the oven: resulting in substantial reĆ
ductions in energy consumption and enhanced
oven performance.
GAS SPECIFICATIONS - U.S., Canada and General Export
Natural Gas Propane Gas
US Units SI Units US Units SI Units
Heating Value 1000 BTU/cu.ft. 37.3 MJ/m
3
2550 BTU/cu. ft. 95.0 MJ/m
3
Specific Gravity (air=1.0) 0.63 0.63 1.53 1.53
Gas Manifold Pressure 3.5" W.C. .87 kPa 10" W.C. 2.49 kPa
Oven Input 27,500 BTU/hr
34,500 BTU/hr
8.1 kW
10.1 kW
27,500 BTU/hr
34,500 BTU/hr
8.1 kW
10.1 kW
Main Burner Orifice Size 38 MTD*
32 MTD*
2.6 mm
2.9 mm
1/16" dia.
50 MTD*
1.6 mm
1.75 mm
Pilot Burner Orifice Size .021" dia. .55 mm .011" dia. .28 mm
GAS SPECIFICATIONS - Australia
Oven Input - 32 MJ - 32 MJ
Main Burner Orifice Size 38 MTD* 2.6 mm 1/16" dia. 1.6 mm
Gas Manifold Pressure - .87 kPa - 2.49 kPa
NOTE: *Multiple Twist Drill
Introduction
3
Oven Components
Combustion Cover - provides access to the
combustion compartment on gas ovens.
Combustion Compartment - contains combusĆ
tion burner on gas ovens.
Combustion Burner - provides heat to the bakĆ
ing chamber on gas ovens.
Control Panel - contains wiring and components
to control the oven operation.
Oven Racks - five racks are provided standard.
Additional racks are available.
Rack Supports - hold oven racks.
Blower Wheel Cover - located on the side interiĆ
or wall of the oven. Protects the blower wheel.
Blower Wheel - spins to circulate hot air in the
baking chamber.
Convection Motor - provides power to turn the
blower wheel.
Rack Support
Oven Rack
Figure 1
Installation
4
Delivery and Location
DELIVERY AND INSPECTION
All Blodgett ovens are shipped in containers to
prevent damage. Upon delivery of your new oven:
D Inspect the shipping container for external damĆ
age. Any evidence of damage should be noted
on the delivery receipt which must be signed by
the driver.
D Uncrate the oven and check for internal damĆ
age. Carriers will accept claims for concealed
damage if notified within fifteen days of delivery
and the shipping container is retained for inĆ
spection.
The Blodgett Oven Company cannot assume
responsibility for loss or damage suffered in
transit. The carrier assumed full responsibility
for delivery in good order when the shipment
was accepted. We are, however, prepared to
assist you if filing a claim is necessary.
OVEN LOCATION
The well planned and proper placement of your
oven will result in long term operator convenience
and satisfactory performance.
The following clearances must be maintained beĆ
tween the oven and any combustible or nonĆcomĆ
bustible construction.
D Oven body right side - 6" (15 cm)
D Oven body left side - 6" (15 cm)
D Oven body back - 6" (15 cm)
D Oven body bottom - 6" (15 cm)
The following clearances must be available for serĆ
vicing.
D Oven body sides - 12" (30 cm)
D Oven body back - 12" (30 cm)
NOTE: On gas models, routine servicing can usuĆ
ally be accomplished within the limited
movement provided by the gas hose reĆ
straint. If the oven needs to be moved furĆ
ther from the wall, the gas must first be
turned off and disconnected from the oven
before removing the restraint. Reconnect
the restraint after the oven has been reĆ
turned to its normal position.
It is essential that an adequate air supply to the
oven be maintained to provide a sufficient flow of
combustion and ventilation air.
D Place the oven in an area that is free of drafts.
D Keep the oven area free and clear of all combusĆ
tibles such as paper, cardboard, and flammable
liquids and solvents.
D Do not place the oven on a curb base or seal to
a wall. This will restrict the flow of air and prevent
proper ventilation. Tripping of the blower moĆ
tor's thermal overload device is caused by an
excessive ambient temperature on the right
side of the oven. This condition must be corĆ
rected to prevent permanent damage to the
oven.
D The location must provide adequate clearance
for the air opening into the combustion chamĆ
ber.
Before making any utility connections to this oven,
check the rating plate to be sure the oven specifiĆ
cations are compatible with the gas and electrical
services supplied for the oven.
1. Remove the combustion compartment cover.
The rating plate is attached to the frame in the
combustion compartment.
Installation
5
Stand Assembly
STAND OPTIONS
Small Stands Without Shelves
D The 5Ć3/4" (15cm) stand is used for a single
oven, when short legs are required for counterĆ
top use.
D The 7" (18cm) stand is used for a double
stacked oven, when the oven is to be located on
the floor.
Stands With Shelves
D Three stands, 16" (40cm), 19" (48cm), and 24"
(61cm) are available for different installation reĆ
quirements.
D The 33" (84cm) stand is used for a single oven
when counter space is limited.
Open Stands With Racks
D The 24" (61cm) or 33" (84cm) open stands are
available with a rack support system located beĆ
low the oven.
STAND ASSEMBLY
Small Stands Without Shelves
1. Place stand frame upside down on a work surĆ
face.
2. Attach one leg to each of the corner stud bolts
on the bottom of the stand top.
3. Place a lock washer and nut on each stud, and
tighten securely.
4. The stand is now ready for the oven assembly.
Stands With Shelves
1. Place stand frame upside down on a work surĆ
face.
2. Attach one leg to each of the corner stud bolts
on the bottom of the stand top.
3. Place a lock washer and nut on each bolt, and
tighten. DO NOT tighten leg bolts completely.
4. Place the shelf between the legs so that the
smooth top surface is facing the top of the
stand.
5. Align the shelf holes with the bolt holes found
near the bottom of each leg.
6. Insert a carriage bolt from the outside of the
leg, through the leg, and through the shelf corĆ
ner bracket.
7. Place a lock washer and nut on each bolt, and
tighten securely.
8. Tighten the leg frame bolts.
Figure 2
Installation
6
Stand Assembly
Open Stands With Racks
1. Lay stand frame top down on the floor as
shown. See Figure 3.
2. Position the four leg assemblies and support
angles as shown. Attach with the 5/16Ć18 nuts
provided. DO NOT tighten leg bolts completely.
NOTE: Be sure the support angles and clips
are located correctly for your oven
configuration. See Figure 3.
3. Position the bottom shelf between the legs so
that the smooth top surface is facing the top
of the stand.
4. Align the shelf holes with the bolt holes found
near the bottom of each leg.
5. Insert a carriage bolt from the outside of the
leg, through the leg, and through the shelf corĆ
ner bracket.
6. Place a lock washer and nut on each bolt, and
tighten securely. See the Figure 2.
7. Repeat Steps 3-6 for the top shelf.
NOTE: Be sure the slots in the top shelf are
aligned with the support angles.
8. Insert the top of the rack stops into the two
back clips on the angle supports as shown. InĆ
sert the bottom of the rack stops into the slots
in the top shelf as shown.
9. Insert the rack supports into the remaining
four clips on the angle supports as shown. InĆ
sert the bottom of the rack supports into the
slots in the top shelf as shown.
10. Tighten all loose bolts.
Support
Angle
Top Shelf
(rear)
Rack
Support
Attach Rack Supports and Rack Stops
Support
Angle,
RH
Rack
Support
Back of Stand
Rack Stop
Support
Angle, LH
Figure 3
Installation
7
Oven Assembly
OVEN ASSEMBLY TO STAND
Single Section
1. Place the assembled stand in the location
where the oven is going to be used.
2. Remove the side control compartment cover
and open the front control panel of a single
oven (or lower section).
3. With a tool, punch out the knockĆouts in the
oven bottom near each corner.
4. Set the oven on the stand. Center it to the frame.
5. Align the front, and rear bolt holes of the oven
with the bolt holes in the stand.
6. Insert a bolt and washer, from the top down
through each of the 2 holes.
7. Place a nut and washer on each of the 2 bolts,
and tighten securely.
8. Replace the oven's side control compartment,
and close the front control panel.
NOTE: For single section ovens only. For
double stacked ovens step 8 will be
completed once the ovens are stacked.
Figure 4
Double Section
1. Assemble the lower section to the stand as deĆ
scribed. DO NOT replace the side control
compartment or close the front control panel.
2. With a tool, punch out the knockĆouts in the
oven top of the lower oven.
3. Remove the side control compartment cover
and open the front control panel of the upper
oven.
4. With a tool, punch out the knockĆouts in the
bottom of the upper oven near each corner.
5. Set the upper oven on the lower oven.
6. Align the front, and rear bolt holes of the upper
oven with the bolt holes in the bottom oven.
7. Insert a bolt and washer, from the top down
through each of the 2 holes.
8. Place a nut and washer on each of the 2 bolts,
and tighten securely.
9. Replace the control compartment cover, and
close the front control panel on both of the
ovens.
Figure 5
Installation
8
Oven Assembly
LEG ATTACHMENT
4" (10 cm legs)
1. Lay the oven on its back.
2. Screw the legs into the holes in the oven corĆ
ners. Tighten the hex nut at the top of each leg.
3. Tip the oven up on the legs.
4. Turn the adjustable leg feet to level the oven.
Figure 6
OVEN LEVELING
After assembly, the oven should be leveled and
moved to the operating location.
1. The oven can be leveled by adjusting the feet
or casters located on the bottom of each leg.
Installation
9
Ventilation
On gas models the installation of a proper ventilaĆ
tion system cannot be over emphasized. This sysĆ
tem removes unwanted vapors and products of
combustion from the operating area.
This oven may be vented using either:
D A mechanically driven, canopy type, exhaust
hood, or
D A direct flue arrangement.
U.S. and Canadian installations
Refer to your local ventilation codes. In the abĆ
sence of local codes, refer to the National ventilaĆ
tion code titled, Standard for the Installation of
Equipment for the Removal of Smoke and Grease
Laden Vapors from Commercial Cooking EquipĆ
ment", NFPAĆ96ĆLatest Edition.
Australia and General Export installations
Installation must conform with Local and National
installation standards. Local installation codes
and/or requirements may vary. If you have any
questions regarding the proper installation and/or
operation of your Blodgett oven, please contact
your local distributor. If you do not have a local disĆ
tributor, please call the Blodgett Oven Company at
0011Ć802Ć860Ć3700.
WARNING:
Failure to properly vent the oven can be
hazardous to the health of the operator
and may result in operational problems,
unsatisfactory baking and possible damĆ
age to the equipment.
Damage sustained as a direct result of imĆ
proper ventilation will not be covered by
the manufacturer's warranty.
CANOPY TYPE EXHAUST HOOD
A mechanically driven, canopy type exhaust hood
is the preferred method of ventilation.
The hood should be sized to completely cover the
equipment plus an overhang of at least 6" (15 cm)
on all sides not adjacent to a wall. The distance
from the floor to the lower edge of the hood should
not exceed 7' (2.1m).
The total makeup and exhaust air requirements for
hood capacity should be approximately 19 CFM
for each oven section.
Installing the canopy hood draft diverter
Ovens ordered for hood venting are supplied with
a draft diverter. Install the draft diverter as follows:
1. Place the diverter over the flue connector with
the open area facing the right side of the oven.
See Figure 7.
2. Secure with the sheet metal screws provided.
Front of
Oven
Draft Diverter
Figure 7
Installation
10
Ventilation
DIRECT FLUE ARRANGEMENT
When the installation of a mechanically driven exĆ
haust hood is impractical the oven may be vented
by a direct flue arrangement.
WARNING!!
It is essential that the direct flue be
installed as follows. Incorrect installation
will result in unsatisfactory baking and
oven damage.
The flue must be class B or better with a diameter
of 6" (15 cm). The height of the flue should rise 6Ć8
ft (2Ć2.5 m) above the roof of the building or any
proximate structure. Never direct vent the oven
into a hood. The flue should be capped with a UL
Listed type vent cap to isolate the unit from exterĆ
nal environmental conditions.
The direct vent cannot replace air consumed and
vented by the oven. Provisions must be made to
supply the room with sufficient makeĆup air. Total
makeĆup air requirements for each oven section
should be approximately 19 CFM per section. To
increase the supply air entering the room, a venĆ
tilation expert should be consulted.
Installing the draft hood
Ovens ordered for direct venting are supplied with
a draft hood. Install the draft hood as follows:
1. Place the draft hood over the flue connector.
See Figure 8.
2. Secure both ends with the sheet metal screws
provided.
Front of
Oven
Draft Hood
Flue
Figure 8
Installation
11
Utility Connections - Standards and Codes
THE INSTALLATION INSTRUCTIONS CONĆ
TAINED HEREIN ARE FOR THE USE OF QUALIĆ
FIED INSTALLATION AND SERVICE PERSONNEL
ONLY. INSTALLATION OR SERVICE BY OTHER
THAN QUALIFIED PERSONNEL MAY RESULT IN
DAMAGE TO THE OVEN AND/OR INJURY TO
THE OPERATOR.
Qualified installation personnel are individuals, a
firm, a corporation, or a company which either in
person or through a representative are engaged
in, and responsible for:
D the installation or replacement of gas piping
and the connection, installation, repair or servĆ
icing of equipment.
D the installation of electrical wiring from the elecĆ
tric meter, main control box or service outlet to
the electric appliance.
Qualified installation personnel must be experiĆ
enced in such work, familiar with all precautions
required, and have complied with all requirements
of state or local authorities having jurisdiction.
U.S. and Canadian installations
Installation must conform with local codes, or in
the absence of local codes, with the National Fuel
Gas Code, NFPA54/ANSI Z223.1-Latest Edition,
the Natural Gas Installation Code CAN/CGAĆ
B149.1 or the Propane Installation Code, CAN/
CGAĆB149.2 as applicable.
Installation must conform with local codes, or in
the absence of local codes, with the National ElecĆ
trical Code, ANSI/NFPA 70-Latest Edition and/or
Canadian National Electric Code C22.2 as appliĆ
cable.
Australia and General Export installations
Installation must conform with Local and National
installation standards. Local installation codes
and/or requirements may vary. If you have any
questions regarding the proper installation and/or
operation of your Blodgett oven, please contact
your local distributor. If you do not have a local disĆ
tributor, please call the Blodgett Oven Company at
0011Ć802Ć860Ć3700.
Installation
12
Gas Connection
GAS PIPING
A properly sized gas supply system is essential for
maximum oven performance. Piping should be
sized to provide a supply of gas sufficient to meet
the maximum demand of all appliances on the line
without loss of pressure at the equipment.
Example:
NOTE: BTU values in the following example are
for natural gas.
You purchase a DFGĆ50 convection oven to add to
your existing cook line.
1. Add the BTU rating of your current appliances.
Pitco Fryer 120,000 BTU
6 Burner Range 60,000 BTU
Deck Oven 50,000 BTU
Total 230,000 BTU
2. Add the BTU rating of the new oven to the toĆ
tal.
Previous Total 230,000 BTU
DFGĆ50 27,500 BTU
New Total 257,500 BTU
3. Measure the distance from the gas meter to
the cook line. This is the pipe length. Let's say
the pipe length is 40' (12.2 m) and the pipe
size is 1" (2.54 cm).
4. Use the appropriate table to determine the toĆ
tal capacity of your current gas piping.
The total capacity for this example is 320,000
BTU. Since the total required gas pressure,
257,500 BTU is less than 320,000 BTU, the
current gas piping will not have to be inĆ
creased.
NOTE: The BTU capacities given in the tables are
for straight pipe lengths only. Any elbows
or other fittings will decrease pipe capaciĆ
ties. Contact your local gas supplier if you
have any questions.
Maximum Capacity of Iron Pipe in Cubic Feet
of Natural Gas Per Hour
(Pressure drop of 0.5 Inch W.C.)
Pipe
L th (ft)
Nominal Size, Inches
p
Length (ft)
3/4" 1" 1Ć1/4" 1Ć1/4" 2"
10 360 680 1400 2100 3950
20 250 465 950 1460 2750
30 200 375 770 1180 2200
40 170 320 660 990 1900
50 151 285 580 900 1680
60 138 260 530 810 1520
70 125 240 490 750 1400
80 118 220 460 690 1300
90 110 205 430 650 1220
100 103 195 400 620 1150
From the National Fuel Gas Code Part 10 Table 10Ć2
Maximum Capacity of Pipe in Thousands of
BTU/hr of Undiluted L.P. Gas at 11" W.C.
(Pressure drop of 0.5 Inch W.C.)
Pipe Length
(ft)
Outside Diameter, Inches
pg
(ft)
3/4" 1" 1Ć1/2"
10 608 1146 3525
20 418 788 2423
30 336 632 1946
40 287 541 1665
50 255 480 1476
60 231 435 1337
70 215 404 1241
80 198 372 1144
90 187 351 1079
100 175 330 1014
From the National Fuel Gas Code Part 10 Table 10Ć15
Installation
13
Gas Connection
PRESSURE REGULATION AND TESTING
DFGĆ50 ovens are rated at 27,500 BTU/Hr. (8.1
kW) (29 MJ) or 34,500 BTU/Hr. (10.1 kW) (36 MJ)
per section. Each oven has been adjusted at the
factory to operate with the type of gas specified on
the rating plate.
Inlet Pressure
Natural Propane
Min Max Min Max
W.C. 7.0 10.5 11.0 13.0
kPa 1.43 2.61 2.74 3.23
Manifold Pressure
Natural Propane
W.C. 3.5 10.0
kPa .87 2.49
D Inlet Pressure - the pressure of the gas before
it reaches the oven.
D Manifold Pressure - the pressure of the gas
as it enters the main burner(s).
D Min - the minimum pressure recommended to
operate the oven.
D Max - the maximum pressure at which the
manufacturer warrants the oven's operation.
Each oven is supplied with a regulator to maintain
the proper gas pressure. The regulator is essenĆ
tial to the proper operation of the oven and
should not be removed. It is preset to provide the
oven with 3.5" W.C. (0.87 kPa) for natural gas and
10.5" W.C. (2.50 kPa) for Propane at the manifold.
DO NOT INSTALL AN ADDITIONAL REGULATOR
WHERE THE OVEN CONNECTS TO THE GAS
SUPPLY UNLESS THE INLET PRESSURE IS
ABOVE MAXIMUM.
Prior to connecting the oven, gas lines should be
thoroughly purged of all metal filings, shavings,
pipe dope, and other debris. After connection, the
oven should be checked for correct gas pressure.
The oven and its individual shutoff valve must be
disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures in excess of 1/2 psig (3.45kPa).
The oven must be isolated from the gas supply
piping system by closing its individual manual
shutoff valve during any pressure testing of the
gas piping system at test pressures equal or less
than 1/2 psig (3.45kPa).
Gas Connection 4" (101.6 mm)
Gas Connection 2.75" (69.9 mm)
Figure 9
Installation
14
Gas Connection
GAS HOSE RESTRAINT
If the oven is mounted on casters, a commercial
flexible connector with a minimum of 3/4" (1.9 cm)
inside diameter must be used along with a quick
connect device.
The restraint, supplied with the oven, must be
used to limit the movement of the unit so that no
strain is placed upon the flexible connector. With
the restraint fully stretched the connector should
be easy to install and quick connect.
The restraint (ie: heavy gauge cable) should be
1,000 lb. (453 kg) test load and should be attached
without damaging the building. DO NOT use the
gas piping or electrical conduit for the attachment
of the permanent end of the restraint! Use anchor
bolts in concrete or cement block. On wooden
walls, drive hi test wood lag screws into the studs
of the wall.
1. A 3/8" diameter hole has been provided on the
bottom of the oven just below the gas inlet. the
hole is sized to accept a clipĆon restraining
cable supplied with the flex hose.
WARNING!!
If the restraint is disconnected for any
reason it must be reconnected when the
oven is returned to its original position.
U.S. and Canadian installations
The connector must comply with the Standard for
Connectors for Movable Gas Appliances, ANSI
Z21.69 or Connectors For Moveable Gas ApĆ
pliances CAN/CGAĆ6.16ĆM87 and a quick disconĆ
nect device that complies with the Standard for
QuickĆDisconnect Devices for Use With Gas Fuel,
ANSI Z21.41 or Quick Disconnect For Use With
Gas Fuel CAN 1Ć6.9. Adequate means must be
provided to limit the movement of the appliance
without depending on the connection and the
quick disconnect device or its associated piping.
Australia and General Export installations
The restraint and quick connect must conform
with Local and National installation standards. LoĆ
cal installation codes and/or requirements may
vary. If you have any questions regarding the propĆ
er installation and/or operation of your Blodgett
oven, please contact your local distributor. If you
do not have a local distributor, please call the
Blodgett Oven Company at 0011Ć802Ć860Ć3700.
Installation
15
Electrical Connection
Wiring diagrams are located in the motor access
panel and on the back of the oven.
This oven is supplied for connection to 115 volt
grounded circuits. The electric motor, indicator
lights and related switches are connected through
the 6' electric supply cord found at the rear of the
oven.
THE BLODGETT OVEN COMPANY CANNOT ASĆ
SUME RESPONSIBILITY FOR LOSS OR DAMAGE
SUFFERED AS A RESULT OF IMPROPER INSTALĆ
LATION.
WARNING!!
This appliance is equipped with three
prong grounding type plug for your
protection against shock hazard and
should be plugged directly into a properly
grounded three prong receptacle. DO
NOT cut or remove the grounding prong
from this plug.
ELECTRICAL SPECIFICATIONS
Model Hz Volts Phase Amps Electrical Connection
(minimum size)
U.S. and Canadian Installations
DFGĆ50 60 115 1 5 Cord set provided
General Export Installations
DFGĆ50 50 220Ć240 1 3 Size per local code
Installation
16
Initial Startup
The following is a checkĆlist to be completed by
qualified personnel prior to turning on the
appliance for the first time.
j Open the manual shutĆoff valve at the rear of
the oven.
j Remove the control panel and combustion
covers.
j Turn the combination valve's manual shutĆoff
to the on position.
j Turn the selector switch to Cook, and the therĆ
mostat to 500_F (260_C).
With the main burner on, check the following.
j Verify there are no gas leaks, by checking all
gas connections with a soapy water solution.
j Verify that the inlet pressure is correct. The inĆ
let pressure can be checked at the pressure
tap located on the combination valve's inlet
side.
j Verify that the manifold pressure is correct.
The manifold pressure can be checked at the
pressure tap located on the combination
valve's outlet side.
j If the above pressure readings are set to the
recommended pressure requirements, allow
the oven to burnĆoff for 2 hours. If the pressure
readings are not set correctly, turn off the oven
and readjust accordingly.
WARNING
The break in procedure burns off excess
oils present in the metals during fabricaĆ
tion. Smoke may be produced. Proper
ventilation is required.
ADJUSTMENTS ASSOCIATED WITH INITIAL
INSTALLATION
Each oven, and its component parts, have been
thoroughly tested and inspected prior to shipĆ
ment. However, it is often necessary to further
test or adjust the oven as part of a normal and
proper installation. These adjustments are the
responsibility of the installer, or dealer. Since
these adjustments are not considered defects
in material or workmanship, they are not covĆ
ered by the Original Equipment Warranty. They
include, but are not limited to:
D calibration of the thermostat
D adjustment of the doors
D burner adjustments
D leveling
D testing of gas pressure
D tightening of fasteners.
No installation should be considered complete
without proper inspection, and if necessary,
adjustment by qualified installation or service
personnel.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90

Blodgett DFG-50 Mode d'emploi

Taper
Mode d'emploi

dans d''autres langues