Star 808HA Le manuel du propriétaire

Taper
Le manuel du propriétaire
Star
Manufacturing
International Inc.
10 Sunnen Drive
St. Louis, MO 63143
Phone: (314) 678-6303
Fax: (314) 781-2714
Installation and
Operating Instructions
Instructions d’installation
et d’opération
ULTRA-MAX™ GAS HOTPLATE MODELS
HOTPLATE DE GAZ ULTRA-MAX™ MODÈLES
802HA, 804HA,
806HA, and 808HA
2M-Z16166 Rev. A 1/23/14
WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause
property damage, injury or death. Read
the installation, operating and maintenance
instructions thoroughly before installing or
servicing this equipment.
FOR YOUR SAFETY: Do not store or use
gasoline or other ammable vapors or liquids
in the vicinity of this or any other appliance.
WARNING: This appliance shall be installed
in accordance with current regulations and
used only in well-ventilated space. Refer to
instructions before installing and using this
appliance.
In addition, there should be posted, in a
prominent location, detailed instructions to
be followed in the event the operator smells
gas. Obtain the instructions from the local gas
supplier.
AVERTISSEMENT: L’installation inexacte, le réglage,
le changement, le service ou l’entretien peuvent causer
des dégats matériels, des dommages ou la mort. Lisez
les instructions d’installation, d’opération et d’entretien
complètement avant d’installer ou entretenir ce matériel.
AVERTISSEMENT: Cet appareil sera installé selon des
règlements actuels et utilisé seulement dans l’espace
bien-aéré. Référez-vous aux instructions avant d’installer
et utiliser cet appareil.
POUR VOTRE SÛRETÉ: N’enregistrez pas ou
n’utilisez pas l’essence ou d’autres vapeurs ou liquides
inammables à proximité de ceci ou d’aucun autre
appareil.
En outre, là devrait être signalé, dans un emplacement
en avant, des instructions détaillées d’être suivi en cas
que l’opérateur sent le gaz. Obtenez les instructions du
fournisseur local de gaz.
2
These symbols are intended to alert the user to the presence of
important operating and maintenance instructions in the manual
accompanying the appliance.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE
Using any part other than genuine Star factory supplied parts relieves the
manufacturer of all liability.
Star reserves the right to change specications and product design without
notice. Such revisions do not entitle the buyer to corresponding changes,
improvements, additions or replacements for previously purchased
equipment.
Due to periodic changes in designs, methods, procedures, policies and
regulations, the specications contained in this sheet are subject to change
without notice. While Star International Holdings Inc., Company exercises
good faith efforts to provide information that is accurate, we are not
responsible for errors or omissions in information provided or conclusions
reached as a result of using the specications. By using the information
provided, the user assumes all risks in connection with such use.
MAINTENANCE AND REPAIRS
Contact your local authorized service agent for service or required maintenance.
Please record the model number, serial number, voltage and purchase date in the area below and have it ready when
you call to ensure a faster service.
SAFETY SYMBOL
Model No.
Serial No.
Voltage
Purchase Date
Business 8:00 am to 4:30 p.m. Central Standard Time
Hours:
Telephone: (314) 678-6303
Fax: (314) 781-2714
Website: www.star-mfg.com
Service Help Desk
Authorized Service Agent Listing
Reference the listing provided with the unit
or
for an updated listing go to:
Website: www.star-mfg.com
Mailing Address: Star International Holdings Inc., Company
10 Sunnen Drive
St. Louis, MO 63143
U.S.A
3
2M-Z16116, Ultra-Max Gas Hotplates
Specications
Model
Manual
Controls
BTU/HR
BTU/HR
per burner
Approx Weight Dimensions
Installed Shipped Width Depth Height
802HA 2 60,000
30,000 Nat /
26,000 LP
70 lbs (31.7 kg) 120 lbs ( 54.4 kg) 12” (30.5 cm)
30 5/8”
(77.8 cm)
14 7/8”
(37.8 cm)
804HA 4 120,000 140 lbs (63.5 kg) 216 lbs (97.9 kg) 24” (61 cm)
806HA 6 180,000 210 lbs (95.2 kg) 294 lbs (133.3 kg) 36” (91.4 cm)
808HA 8 240,000 280 lbs (127 kg) 380 lbs (172.3 kg) 48” (122 cm)
DEPTH
3/4” NPT
WIDTH
4”
2”
5 7/16”
19.78”
22.26”
24.72”
13 31/32”
14 7/8”
GAS INLET
IL2504
Width
Depth
Height
IL2508
Specications
Model
Manual
Controls
BTU/HR
BTU/HR
per burner
Approx Weight Dimensions
Installed Shipped Width Depth
Height
(Front)
Height
(Rear)
802HA-SU 2 60,000
30,000 Nat /
26,000 LP
74 lbs (33.5 kg) 124 lbs ( 56.2 kg) 12” (30.5 cm)
30 5/8”
(77.8 cm)
13.8”
(35.1 cm)
17.8”
(45.2 cm)
804HA-SU 4 120,000 145 lbs (65.7 kg) 221 lbs (100 kg) 24” (61 cm)
806HA-SU 6 180,000 215 lbs (97.5 kg) 299 lbs (135.6 kg) 36” (91.4 cm)
808HA-SU 8 240,000 286 lbs (129.7 kg) 386 lbs (175.0 kg) 48” (122 cm)
4
2M-Z16116, Ultra-Max Gas Hotplates
GENERAL INSTALLATION DATA
This equipment is designed and sold for commercial use only by personnel trained and experienced
in its operation and is not sold for consumer use in and around the home nor for use directly by the
general public in food service locations.
The Ultra-Max™ series gas hotplate is equipped for the type of gas indicated on the nameplate
mounted on the front panel. All units are shipped from the factory for use with natural gas. The unit can
easily be converted for use with propane gas: see propane gas.
-IMPORTANT-
Be sure to remove all paper protection and packing material from unit prior to lighting.
Install on non-combustible countertop with 4" legs or combustible oor using a maximum
27" high stand. Clearance from combustible construction must be 9" minimum from
back wall and 7" from side walls. Clearance from non-combustible surfaces on back
and sides may be 0". For servicing, 6" is recommended from back of unit on non-
combustible walls.
The installation of the Appliance must conform to the NATIONAL FUEL GAS
CODE "ANSI Z223.1 - LATEST EDITION" AND ALL LOCAL GAS COMPANY
RULES AND REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE CURRENT
CAN/CGA-B149.1 NATURAL GAS INSTALLATION CODE OR CAN/CGA-B149.2
PROPANE INSTALLATION CODE AND LOCAL CODES WHERE APPLICABLE
NOTICE
When this appliance is installed with casters, it must be installed with the casters supplied, a connector
complying with either ANSI Z21.69 or CAN/CGA-6.16 and a quick-disconnect device complying with
either ANSI Z21.41 or CAN1-6.9. It must also be installed with restraining means to guard against
transmission of strain to the connector, as specied in the appliance manufacturer's instructions.
For your protection, we recommend a qualied installing agency install this
appliance. They should be familiar with gas installations and your local gas
requirements. In any case, your gas company should be called to approve the
nal installation.
This appliance, its pressure regulator and its individual shutoff valve must be disconnected from the
gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2
PSIG. This appliance and its pressure regulator must be isolated from the gas supply piping system by
closing its individual manual shutoff valve during any pressure testing of the gas supply piping system
at test pressures equal to or less than 1/2 PSIG.
EXHAUST CANOPY
Open hotplates create fumes, moisture, heat, and should be installed under an efcient exhaust hood
with ame proof lters. A vertical distance of not less than 48" shall be provided between the top of
the appliance and lters or any other combustible material. Exhaust installation must conform to local
codes.
AIR SUPPLY
Provisions for adequate air supply must be provided.
AIR INTAKES IN BOTTOM
Air for combustion enters from the front and bottom of the unit. Do not obstruct this area.
CAUTION
CAUTION
5
2M-Z16116, Ultra-Max Gas Hotplates
LEVELING UNIT
This hotplate is supplied with 4 feet or oor stand legs
which must be screwed into the body. Unit must be
level. Level unit by adjusting the (4) feet which have an
adjustment of 1-3/4" for accurate and perfect line-up with
other units.
Caster Kits: Casters can be used with oor stand models or optional equipment stand. For installation, carefully mark
and cut off from the bottom of each leg using a straight cutting saw and de-burr the inside tube wall prior to installing the
caster. Cut leg should measure 19" tube length, not overall length. On SFC models only, use kit number ES-UM36SFC.
Casters add about 6-1/4" of height to the unit. Be sure to use approved strain relief means for protecting gas line
connection. If an appliance is equipped with casters and is gas connected with a quick connect coupling, all personnel
must be aware that there is a restraint on the appliance and if disconnected for service or cleaning it must be reconnected
as originally installed prior to use.
DO NOT INSTALL WITHOUT ATTACHING
FEET OR SUPPLIED STAND LEGS AND
SHELF - DO NOT REMOVE FEET.
CAUTION
SCREW LEGS INTO
MOUNTING NUTS ON BOTTOM
FLOOR STAND SHELF
STIFFENING SUPPORTS FOR
808 MODELS ONLY
FLOOR STAND MODEL
(Floor stand not available for 802 models)
COUNTER TOP MODEL
ON OPTIONAL EQUIPMENT STAND
IL2506
6
2M-Z16116, Ultra-Max Gas Hotplates
GAS PIPING
Gas piping shall be of such size and so installed as to provide a supply of gas sufcient to meet the
full gas input of the appliance. If the appliance is to be connected to existing piping, it shall be checked
to determine if it has adequate capacity. Joint compound shall be used sparingly and only on the male
threads of the pipe joints. Such compounds shall be resistant to the action of L.P. gases. WARNING:
Any loose dirt or metal particles which are allowed to enter the gas lines on this appliance will damage
the valve and affect its operation. When installing this appliance, all pipe and ttings must be free from
all internal loose dirt.
GAS PRESSURE REGULATOR
A convertible pressure regulator is provided with each hotplate. It should be connected to the inlet pipe
at the rear of the unit. The gas supply is then connected to it. The supply pressure to the regulator is not
to exceed 1/2 PSIG. It is shipped set for 5" water column manifold pressure for use with natural gas.
MANUAL SHUT OFF VALVE
A manual shut off valve should be installed upstream from the manifold and within six feet of the
hotplate.
CONNECTING GAS SUPPLY LINE
The gas inlet of the hotplate is sealed at the factory to prevent entry of dirt. Do not remove this seal until
the actual connection is made to the gas supply line.
PROPANE GAS - CONVERSION
This hotplate is equipped with xed orice hoods and is shipped from the factory for use with natural
gas. To convert to propane gas, install the burner orice hoods, located on the manifold, as follows:
1. Remove grates and burners.
2. Remove the burner orice hoods and install the orice hoods supplied.
3. Replace the burners and grates. Be sure venturi opening is positioned on valve orice.
4. Set manifold pressure to (10) inch water column. A 1/8" pipe plug on the burner manifold
can be removed for attaching a pressure gauge. Remove the slotted, or hex-threaded plug from
the pressure regulator. Invert the plug and re-install. The letters "LP" should now be visible on
the plug. The regulator is now set for 10" (25.4 cm) water column. Attach the conversion label,
supplied with the unit, close to the nameplate on the top side of the front panel. Pilot ame may
need to be adjusted for LP gas.
CHECKING FOR GAS LEAKS
Check entire piping system for leaks. Soap and water solution or other material acceptable for the
purpose, shall be used in locating gas leakage.
Matches, candle ame or other sources of ignition shall not be used for locating gas
leaks.
PILOT LIGHTING INSTRUCTIONS
The hotplate is equipped with factory pre-set standing pilots and should be lit immediately after the gas
is turned on. Pilot lights may need an adjustment based on local gas supplies. See below for pilot light
adjustments.
If the operator smells gas or the pilot lights need to be relit:
1. Turn off main valve to unit.
2. Turn off all knobs and pilot valves and wait 5 minutes to clear gas.
3. The pilot lights on this hotplate can be adjusted by turning the adjustable screw
counterclockwise to open and clockwise to close.
4. Turn on main valve and light all pilots.
5. Adjust pilot light ames as small as possible around pilot head, usually about 1/4" high,
but high enough to light burner immediately when burner valve is turned on high.
6. Turn burner knobs to desired setting.
7. To turn burners off, turn knobs clockwise to "OFF."
If interuption of the gas supply occurs, reliting of the pilot light will be needed.
CAUTION
7
2M-Z16116, Ultra-Max Gas Hotplates
BURNER IGNITION AND ADJUSTMENT
1. To ignite burners turn burner valve knob counter clockwise to "ON"position.
2. Slowly decrease openings of air shutters to give a soft blue ame having luminous tips,
then slowly increase openings to a point where the yellow tips disappear and a hard blue
ame is obtained.
LIGHTING
When hotplate is rst lit, it may smoke for approximately 20-30 minutes until the preservation
oils and impurities are burned off.
OPERATING INSTRUCTIONS
BOTTOM CRUMB PAN
The crumb pan is located at the bottom of the unit, and is easily removed from the front of the unit for
cleaning. Be sure it is in place during operation.
BURNER OPERATION
Each burner is controlled by an individual on-off valve. A variety of temperatures may be obtained
by turning the burner valve knob to any position between ON and OFF. It is possible through this
arrangement to have a high heat section, while having a low heat simmering or holding section. For
the high heat operation, turn the valve counter clockwise for the section to a position of ON or close to
it. For holding or simmering, turn the valves closer to the OFF position on the dial. If even less heat
is required, the valve may be turned OFF and the product kept warm on the pilot ame. You select the
heat pattern you like and set the valves accordingly. Be sure burners are staying fully lit when set in low
positions.
COMPLETE SHUTDOWN INSTRUCTIONS
Turn the burner valve knobs to the OFF position to turn burners off and close manual valve gas shutoff.
CLEANING
Clean regularly. Be sure appliance has cooled down. Remove grate section and burner head to sink
for washing. Brush out carboned particles. Venturi must be free from grease, dirt, lint, or any foreign
material. Remove and wash crumb pan. Be sure to replace top grates laying at and centered over
the burner. Wipe exterior surfaces with a mild detergent and a cloth. A non-abrasive cleaner can be
used on caked areas. Be careful with spraying on some cleaners as they may contain abrasives and
caustics which could scratch or damage the nish.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

Star 808HA Le manuel du propriétaire

Taper
Le manuel du propriétaire

dans d''autres langues