800.879.8585
www.legrand.us/wattstopper
No. 24619 – 09/16 rev. 1
© Copyright 2016 Legrand All Rights Reserved.
© Copyright 2016 Tous droits réservés Legrand.
© Copyright 2016 Legrand Todos los derechos reservados.
Wattstopper warranties its products to be free
of defects in materials and workmanship for a
period of five (5) years. There are no obligations
or liabilities on the part of Wattstopper for
consequential damages arising out of, or in
connection with, the use or performance of this
product or other indirect damages with respect
to loss of property, revenue or profit, or cost of
removal, installation or reinstallation.
Wattstopper garantit que ses produits sont
exempts de défauts de matériaux et de fabrication
pour une période de cinq (5) ans. Wattstopper
ne peut être tenu responsable de tout dommage
consécutif causé par ou lié à l’utilisation ou
à la performance de ce produit ou tout autre
dommage indirect lié à la perte de propriété, de
revenus, ou de profits, ou aux coûts d’enlèvement,
d’installation ou de réinstallation.
Wattstopper garantiza que sus productos
están libres de defectos en materiales y mano
de obra por un período de cinco (5) años. No
existen obligaciones ni responsabilidades por
parte de Wattstopper por daños consecuentes
que se deriven o estén relacionados con el
uso o el rendimiento de este producto u otros
daños indirectos con respecto a la pérdida
de propiedad, renta o ganancias, o al costo
de extracción, instalación o reinstalación.
WARRANTY INFORMATION INFORMATIONS RELATIVES À LA GARANTIE INFORMACIÓN DE LA GARANTÍA
The DLM local network uses free topology low voltage wiring. The LMRL-100 can connect anywhere on the DLM local network.
Terminal Connections
LMRJ Cables
Loads
1
2
Line Voltage
Room
Controller
Switch
LMRL-100
Relay output to
third party device
RLY NC
(normally closed)
RLY COM
To 3rd
party
device
Contacts rated at
1 amp @ 24V AC/DC
RLY NO
(normally open)
Isolated Relay
Terminals
11444r1
N.C.
Common
N.O.
Relay
Terminals
Connect to
Wattstopper
Digital Lighting
Management
Class 2 power source. Pat. Pending
LED lit when
relay active.
www.legrand.us/wattstopper
.
Connect to DLM local network only
NOT Ethernet
Normally Open
OPERATION
The LMRL-100 connects to the DLM local network. When occupancy is detected by any sensor on the DLM local network the
LMRL-100 automatically closes its relay. The output from the LMRL-100 terminal can signal a third party device that there is occupancy.
Power Up Functionality
Upon initial power up the LMRL-100 automatically “listens” for an occupancy message from any occupancy sensor on the local network.
No setup is needed.
LED Indicator
The LMRL-100 contains one blue LED that illuminates when the isolated relay closes.
TROUBLESHOOTING
Relay does not close when the room is occupied:
1. Check that the circuit breaker has been turned back on.
2. Make sure that there is an occupancy sensor detecting occupancy.
3. Check all sensor and room controller wiring connections.
4. Check for 24VDC input to the LMRL-100: Plug in a different DLM device at the LMRL-100 location. If the device does not power
up, 24VDC is not present.
• Check the high voltage connections to the room controller.
• If high voltage connections are good, recheck local network connections between the LMRL-100 and the room controller.
CAUTION: TO CONNECT A COMPUTER TO THE DLM LOCAL NETWORK USE THE
LMCI-100. NEVER CONNECT THE DLM LOCAL NETWORK TO AN ETHERNET
PORT – IT MAY DAMAGE COMPUTERS AND OTHER CONNECTED EQUIPMENT.