Airthings AS 2930 Wave Plus – Radon & Air Quality Monitor Manuel utilisateur

Taper
Manuel utilisateur

Ce manuel convient également à

Airthings Wave Plus
Smart Radon Detector with Indoor Air Quality Sensors Operating manual
Version 4, September 24, 2018
Set up your Airthings device in 3 simple steps:
1. Download the Airthings Wave App, available on iOS and Android
2. Create an account and insert Name, Email and Location*
3. Follow the simple instructions in the app to connect your device
*We encrypt and securely store your information in the Airthings Cloud. Providing your location is optional, however, sharing your radon
information helps us understand how regional radon works and can ultimately save lives.
Many easy ways to contact Airthings
Have any questions or comments that we didn’t get to here? Let us know! support.airthings.com
Congratulations on taking this important step toward living a healthier life.
By keeping track of your Indoor Air Quality and radon levels, you can make healthier decisions in
the spaces where you spend most of your time. Increased productivity and energy levels, better
quality sleep, and resistance to illness are just a few of the benefits. Lessening your exposure to
radon will reduce your risk of lung cancer.
The Airthings Wave Plus provides you with detailed information about Radon, Airborne chemicals,
CO2, Temperature, Humidity and Air Pressure levels on your phone, Airthings Dashboard or
simply wave in front of the device for a visual indication of your radon levels.
Breathe better, live better,
The Airthings team
Features and content
1. Power indicator
2. Light ring
3. Motion sensor
4. Air inlets
5. Battery compartments (observe polarity
symbols)
6. One-time battery tab
7. Individual serial number
8. Mounting bracket
9. Screw
10. 2 AA batteries, inserted
Power Indicator
Flashing dot every 20 seconds
Green: battery level okay
Blue: App communication active
Red: Replace batteries
Light Ring
Visual indication of your air quality levels.
Green: Good
Yellow: Fair
Red: Poor
(Go to airthings.com/thresholds for more information on your air
quality action levels)
Air Inlets
This is where air comes into your detector.
Audio Alarm
The device can give you audio alerts if your
air quality levels are violating the
recommended amount. In case of audio
alerts, simply wave in front of the device to
snooze alerts.
Wave Sensor
Simply wave in front of your detector to
activate the light ring.
Basics of the App
*All sensor measurements are adjustable to your country’s unit
system.
Easy to mount
Fix the mounting bracket to the ceiling or
wall. Make sure you use appropriate screws
for your wall type. The screws included are
intended for wood or drywall. Do not place it
close to vents or windows. Minimum 1 meter
/ 3 feet distance.
Thanks to the built-in magnet, simply snap
the unit onto the mounted bracket. Then
rotate it to the desired position.
Initial setup
You’ll receive your first radon reading in
about an hour but we recommend leaving
your Wave Plus uninterrupted for at least 1
week for an accurate radon reading. Radon
levels fluctuate daily which is why continuous
monitoring is necessary. The TVOC and CO2
sensors require at least 1 week for the initial
internal calibration.
Daily use
Wave in front of your device to see a visual
indication of your overall Indoor Air Quality.
Make sure you always have
Bluetooth enabled on your
phone and the app running
in the background. Every
time you are in range of your
device, the latest data will be
synced automatically. You
will be notified if any actions
are needed through the app.
The Wave Plus will enter
stand-alone mode if not
connected to a phone the last 7 days. Next
time the Wave Plus is connected to a phone
again, it will go back to regular connected
mode.
The Wave Plus also includes Airthings
Smartlink which works with the Hub. Refer to
the Hub manual for the Smartlink info. The
Hub provides longer range as well as live
updates using the Airthings Smartlink.
Magnetic
Integrations
The Airthings Wave Plus shares data to your
mobile device as well as the Airthings
Dashboard—a free online platform that
provides quick access to view, customize and
analyze sensor data from multiple Airthings
devices. Go to airthings.com/dashboard for
more info.
The Airthings Wave Plus is integrated with
Amazon Alexa Google Assistant and IFTTT.
With Amazon Alexa and Google Asisstant,
use voice commands to control your device.
IFTTT integration allows users to create or
access useful recipes for their device to follow
and integrate with third-party products. Sign
up for our newsletter for the latest updates.
Glow ring
For details on sensor thresholds go to airthings.com/wave-plus
Sensor icons
Indoor air contaminants vary depending on inhabitants and ventilation, as well as the contents
and use of the space. Continuous monitoring is essential to understand trends and optimize
ventilation to avoid negative effects on your overall health.
Radon – Decrease exposure to this radioactive gas that accumulates in
buildings and homes. It is the number one cause of lung cancer among non-
smokers but can be managed with continuous monitoring.
Total Volatile Organic Compounds – TVOCs are vapors emitted from all sorts
of daily products including paints and furniture, wax and cosmetics, cleaning
and hobby products, cooking and human breath. At high concentrations they
can be harmful and cause negative side-effects from minor eye, nose and
throat irritations all the way to liver and kidney damage and even cancer,
depending on the level and length of exposure.
Carbon Dioxide CO2 is an invisible gas which rises to unhealthy levels
indoors. It can cause headaches, restlessness and drowsiness as well as affect
decision-making skills. High levels are directly correlated to low productivity,
absenteeism and infectious disease transmission.
Humidity – Too much or too little humidity can affect allergies and cold or flu
symptoms. When humidity levels are too high, mold and rot will occur. Low
humidity levels cause static electricity, dry skin and hair, and increased
susceptibility to colds and respiratory illness.
Temperature – Indoor temperatures can affect performance, mood and
comfort level. Individual sleep patterns are also affected by indoor air
temperature.
Pressure – Barometric pressure is the pressure given by the atmosphere at
any given point. It is known as the “weight of the air” and changes
depending on your elevation, as well as weather patterns. It can cause
headaches.
Troubleshooting
First and foremost, always make sure that you
have updated to the latest device software
In the device settings menu, click update
device.
Not able to connect to my device
Make sure you have the detector within
the range of 2-5 meters or 5-15 feet.
Check if Bluetooth is turned on.
Check if the power indicator is blinking.
Need to turn off the audio alert
In the iOS app, go to device settings
menu and update radon alarm settings.
Wave in front of the detector to snooze
for 1 month.
My app is not updated when running in
background mode
Open your phone settings and verify that
the Airthings Wave app is running in the
background. You can usually find this in
the app manager section of your phone
settings.
Make sure you are in Bluetooth range
periodically.
No response from light ring
Check if the power indicator is blinking.
If the power indicator is blinking red, or
not blinking at all, the battery level is low.
First, sync your data and then replace the
batteries. We recommend AA alkaline
(LR6).
If you need further assistance, read our
Frequently Asked Questions, or simply contact
support at support.airthings.com.
Technical specifications
Power supply: 2 AA 1.5V alkaline (LR6)
3.0V nominal (2x1.5V)
3.8V maximum, 1.8V
minimum (depleted batteries)
500mA max current draw
Dimensions: Diameter: 120 mm (4.72in)
Height: 36 mm (1.42in)
Weight: 219g including 2 batteries (7.7 oz)
Operational and storage environment:
Temperature: 4 °C (39 °F) to +40 °C (104 °F)
Relative humidity: < 85%
Settling time:
TVOC ~ 7 days
CO2 ~ 7 days
CO2 details:
NDIR Sensor (Non-Dispersive Infra-Red)
Measurement range 4005000 ppm
Non-condensing 0 85%RH
Optimum Accuracy ±30ppm ±3% within 60 - 95°F
and 0 80%RH can be reached after multiple settling cycles
on locations with natural indoor CO2 fluctuations
Radon details:
Measurement range: 0 Bq/m3 to 20,000 Bq/m3
(0 pCi/L to 500 pCi/L)
Initial accuracy/precision for Radon at 200 Bq/m3
(5.4 pCi/L):
7 days ~ 10%
2 months ~ 5%
See more specs in our Wave Plus Product sheets.
Safety and maintenance
The Airthings Wave Plus is intended for indoor use only.
Avoid direct exposure to sunlight for long periods. Avoid
exposure to direct heat sources. For correct usage, make
sure the detector is operating in the specified temperature
range (see technical specifications).
Exposure to high humidity might permanently alter the
detector sensitivity or damage it.
Do not disassemble. If the detector does not work as
specified or you are in doubt, contact your local dealer or
visit us at Airthings.com.
Use a dry cloth to clean the detector.
When replacing the batteries, pay attention to the polarity
marks. Use AA alkaline (LR6) batteries.
Always snap the mounting bracket to the detector’s rear side
to protect the batteries, even when the detector is not
permanently mounted.
Disposal: electronic equipment.
Limited liability
The instrument is tested and quality-assured by production.
It meets the accuracy values set out in the specifications.
It is recommended to keep the instrument constantly
activated and the batteries in place until drained.
Airthings AS shall not be liable for damages related to failure
or loss of data arising from incorrect operations and handling
of the instrument.
Terms & conditions
airthings.com/terms-use-privacy/
For other languages or additional questions go to
support.airthings.com
The Bluetooth word mark and logos are registered
trademarks owned by the Bluetooth SIG, Inc. and any use of
such marks by Airthings is under license.
Copyright Airthings AS, 2018
Regulatory
information
Regulatory information Canada
Changes or modifications not expressly approved by
the party responsible for compliance could void the
user’s authority to operate the equipment.
Les changements ou modifications non expressément
approuvés par la partie responsable de la conformité
pourraient annuler l'autorisation de l'utilisateur
d'utiliser l'équipement.
This device complies with Innovation, Science and
Economic Development Canada’s licence- exempt
RSS(s). Operation is subject to the following two
conditions: (1) This device may not cause
interference; and (2) This device must accept any
interference, including interference that may cause
undesired operation of the device.
Le présent appareil est conforme aux CNR de l’ISDE
applicables aux appareils radio exempts de licence.
L'exploitation est autorisée aux deux conditions
suivantes : (1) l'appareil ne doit pas produire de
brouillage, et (2) l'utilisateur de l'appareil doit
accepter tout brouillage radioélectrique subi, même
si le brouillage est susceptible d'en compromettre le
fonctionnement.
RF exposure safety
This product is a radio transmitter and receiver.
It is designed not to exceed the emission limits for
exposure to radio frequency (RF) energy set by the
ISED.
The antenna must be installed and operated with
minimum distance of 20 cm between the radiator
and your body.
This transmitter must not be co-located or operating
in conjunction with any other antenna or transmitter.
Ce produit est un émetteur et un récepteur radio.
Il est conçu pour ne pas dépasser les limites
d'émission pour l'exposition à l'énergie
radiofréquence (RF) établie par l'ISDE.
L’antenne doit être installé de façon à garder une
distance minimale de 20 cm entre la source de
rayonnements et votre corps.
L’émetteur ne doit pas être colocalisé ni fonctionner
conjointement avec à autre antenneou autre
émetteur.
CAN ICES-3 (B)/NMB-3(B)
This Class B digital apparatus complies with
Canadian ICES-003
Cet appareil numérique de clase B est conforme à la
norme Canadienne ICES-003
Regulatory information USA
Changes or modifications not expressly approved by
the party responsible for compliance could void the
user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
undesired operation.
Class B device notice
NOTE: This equipment has been tested and found to
comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against
harmful interference in a residential installation. This
equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However,
there is no guarantee that interference will not occur
in a particular installation. If this equipment does
cause harmful interference to radio or television
reception, which can be determined by turning the
equipment off and on, the user is encouraged to try
to correct the interference by one or more of the
following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment
and receiver.
—Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV
technician for help.
RF exposure safety
This product is a radio transmitter and receiver.
It is designed not to exceed the emission limits for
exposure to radio frequency (RF) energy set by the
Federal Communications Commission.
The antenna must be installed and operated with
minimum distance of 20 cm between the radiator
and your body.
This transmitter must not be co-located or operating
in conjunction with any other antenna or transmitter.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Airthings AS 2930 Wave Plus – Radon & Air Quality Monitor Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à