Extron DTP T HWP 4K 331 D Manuel utilisateur

Catégorie
Prolongateurs AV
Taper
Manuel utilisateur

Ce manuel convient également à

User Guide
DTP T HWP 4K D Series
HDMI Extenders
HDMI Twisted Pair Extender Transmitters
68-2544-01 Rev. D
01 19
Safety Instructions
Safety Instructions • English
WARNING: This symbol, , when used on the product, is intended to
alert the user of the presence of uninsulated dangerous voltage within
the product’s enclosure that may present a risk of electric shock.
ATTENTION: This symbol, , when used on the product, is intended
to alert the user of important operating and maintenance (servicing)
instructions in the literature provided with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide, part number 68-290-01, on the Extron
website, www.extron.com.
Sicherheitsanweisungen • Deutsch
WARNUNG: Dieses Symbol auf dem Produkt soll den Benutzer
darauf aufmerksam machen, dass im Inneren des Gehäuses dieses
Produktes gefährliche Spannungen herrschen, die nicht isoliert sind und
die einen elektrischen Schlag verursachen können.
VORSICHT: Dieses Symbol auf dem Produkt soll dem Benutzer in
der im Lieferumfang enthaltenen Dokumentation besonders wichtige
Hinweise zur Bedienung und Wartung (Instandhaltung) geben.
Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung,
EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie in
den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer
68-290-01) auf der Extron-Website, www.extron.com.
Instrucciones de seguridad • Español
ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del
producto, lo que puede representar un riesgo de descarga eléctrica.
ATENCIÓN: Este símbolo, , cuando se utiliza en el producto, avisa
al usuario de la presencia de importantes instrucciones de uso y
mantenimiento recogidas en la documentación proporcionada con el
equipo.
Para obtener información sobre directrices de seguridad, cumplimiento
de normativas, compatibilidad electromagnética, accesibilidad y temas
relacionados, consulte la Guía de cumplimiento de normativas y seguridad
de Extron, referencia 68-290-01, en el sitio Web de Extron, www.extron.com.
Instructions de sécurité • Français
AVERTISSEMENT : Ce pictogramme, , lorsqu’il est utilisé sur le
produit, signale à l’utilisateur la présence à l’intérieur du boîtier du
produit d’une tension électrique dangereuse susceptible de provoquer
un choc électrique.
ATTENTION : Ce pictogramme, , lorsqu’il est utilisé sur le produit,
signale à l’utilisateur des instructions d’utilisation ou de maintenance
importantes qui se trouvent dans la documentation fournie avec le
matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la
réglementation, la compatibilité EMI/EMF, l’accessibilité, et autres sujets
connexes, lisez les informations de sécurité et de conformité Extron, réf.
68-290-01, sur le site Extron, www.extron.com.
Istruzioni di sicurezza • Italiano
AVVISO: Questo simbolo, ,quando viene utilizzato il prodotto, serve
ad avvisare l’utente della presenza di tensioni pericolose non isolate
all’interno del prodotto, che può presentare un rischio di scosse
elettriche.
ATTENTZIONE: Questo simbolo, , quando viene utilizzato il
prodotto, serve ad avvisare l’utente di importanti istruzioni di uso e
manutenzione (assistenza) nella letteratura fornita con l’apparecchiatura.
Per informazioni sulle linee guida di sicurezza, adempimenti normativi,
compatibilità EMI/EMF, accessibilità e argomenti correlati, vedere la sicurezza
di Extron e Regulatory Compliance Guide, parte numero
68-290-01, sul sito Web Extron, www.extron.com.
Instrukcje bezpieczeństwa • Polska
OSTRZEŻENIE: Ten symbol, , gdy używany na produkt, ma na celu
poinformować użytkownika o obecności izolowanego i niebezpiecznego
napięcia wewnątrz obudowy produktu, który może stanowić zagrenie
porażenia prądem elektrycznym.
UWAGI: Ten symbol, , gdy używany na produkt, jest przeznaczony do
ostrzegania użytkownika ważne operacyjne oraz instrukcje konserwacji
(obsługi) w literaturze, wyposażone w sprzęt.
Informacji na temat wytycznych w sprawie bezpieczeństwa, regulacji
wzajemnej zgodności, zgodność EMI/EMF, dostępności i Tematy pokrewne,
zobacz Extron bezpieczeństwa i regulacyjnego zgodności przewodnik, część
numer 68-290-01, na stronie internetowej Extron, www.extron.com.
Инструкция по технике безопасности Русский
ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии неизолированного опасного напряжения
внутри корпуса продукта, которое может привести к поражению электрическим
током.
ВНИМАНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии важных инструкций
по эксплуатации и обслуживанию в руководстве,
прилагаемом к данному оборудованию.
Для получения информации о правилах техники безопасности,
соблюдении нормативных требований, электромагнитной
совместимости (ЭМП/ЭДС), возможности доступа и других
вопросах см. руководство по безопасности и соблюдению
нормативных требований Extron на сайте Extron: ,
www.extron.com, номер по каталогу - 68-290-01.
安全说明 简体中文
警告 产品上的这个标志意在警告用户该产品机壳内有暴露的危险 电压,
险。
注意 产品上的这个标志意在提示用户设备随附的用户手册中有
重要的操作和维护(维修说明
关于我们产品的安全指南、遵循的规范、EMI/EMF 的兼容性、无障碍
使用的特性等相关内容,敬请访问 Extron 网站 , www.extron.com,参见
Extron 安全规范指南,产品编号 68-290-01
安全記事 • 繁體中文
警告: 若產品上使用此號,是為了提醒使用者產品機殼內存在著
可能會導致觸電之風險的未絕緣危險電壓
注意 品上使用此符號,是為提醒使用設備隨戶手冊中有
重要的操作和維(維修説明
有關安全性指導方針法規遵EMI/EMF 相容存取和相主題的詳細
訊,請瀏覽 Extron 網站:www.extron.com然後參《Extron 安全性與法規
守手冊準則編號 68-290-01
安全上の注意
日本語
警告: この 製品上に表示されている場合は、筐体内に絶縁され
いない高電圧が流れ、電の危険があるを示ています
意:この が製上に表示されている場合は、の取明書に
されている重作と保()のについてユーザー
を喚起するものです
安全上の注意、法規厳守、EMI/EMF適合性、その他の関連項
スト イト www.extron.com よ り Extron Safety
and Regulatory Compliance Guide』 ( P/N 68-290-01) をご覧ださい。
안전 지침 • 한국어
경고: 이 기호 가 제품에 사용될 경우, 제품의 인클로저 내에 있는
접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이 있음을
경고합니다.
주의: 이 기호 가 제품에 사용될 경우, 장비와 함께 제공된 책자에 나와
있는 주요 운영 및 유지보수(정비) 지침을 경고합
니다.
안전 가이드라인, 규제 준수, EMI/EMF 호환성, 접근성, 그리고 관련 항목에
대한 자세한 내용은 Extron 웹 사이트(www.extron.com)의 Extron 안전 및
규제 준수 안내서, 68-290-01 조항을 참조하십시오.
FCC Class A Notice
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part15 of the FCC rules. The ClassA limits provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause interference. This interference must be corrected at the expense of the user.
ATTENTION: The Twisted Pair Extension technology works with shielded twisted pair
(STP) cables only. To ensure FCC Class A and CE compliance, STP cables and STP
connectors are also required.
For more information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the “Extron Safety and
Regulatory Compliance Guide” on the Extron website.
Conventions Used in this Guide
Notifications
The following notifications are used in this guide:
CAUTION: Risk of minor personal injury.
ATTENTION : Risque de blessuremineure.
ATTENTION:
Risk of property damage.
Risque de dommages matériels.
NOTE: A note draws attention to important information.
Specifications Availability
Product specifications are available on the Extron website, www.extron.com.
Extron Glossary of Terms
A glossary of terms is available at http://www.extron.com/technology/glossary.aspx.
Copyright
© 2017
-2019 Extron Electronics. All rights reserved.
Trademarks
All trademarks mentioned in this guide are the properties of their respective owners.
The following registered trademarks
®
, registered service marks
(SM)
, and trademarks
(TM)
are the property of RGB Systems, Inc. or
Extron Electronics (see the current list of trademarks on the Terms of Use page at www.extron.com):
Registered Trademarks
(®)
AVTrac, Cable Cubby, ControlScript, CrossPoint, DTP, eBUS, EDID Manager, EDID Minder, Extron, Flat Field, FlexOS, Global Configurator,
GlobalScripter, GlobalViewer, Hideaway, Inline, IPIntercom, IPLink, KeyMinder, LinkLicense, LockIt, MediaLink, MediaPort, NetPA,
PlenumVault, PoleVault, PowerCage, PURE3, Quantum, SoundField, SpeedMount, SpeedSwitch, SystemINTEGRATOR, TeamWork, TouchLink,
V-Lock, VersaTools, VN-Matrix, VoiceLift, WallVault, WindoWall, XTP, and XTPSystems
Registered Service Mark
(SM)
: S3 Service Support Solutions
Trademarks
(
)
AAP, AFL (Accu-RateFrameLock), ADSP(Advanced Digital Sync Processing), Auto-Image, CableCover, CDRS(ClassD Ripple Suppression),
DDSP(Digital Display Sync Processing), DMI (DynamicMotionInterpolation), DriverConfigurator, DSPConfigurator, DSVP(Digital
Sync Validation Processing), eLink, EQIP, EverLast, FastBite, FOX, FOXBOX, HyperLane, IP Intercom HelpDesk, MAAP, MicroDigital,
Opti-Torque, ProDSP, QS-FPC(QuickSwitch Front Panel Controller), Room Agent, Scope-Trigger, ShareLink, Show Me, SIS,
SimpleInstructionSet, Skew-Free, SpeedNav, Triple-Action Switching, True4K, Vector™ 4K , WebShare, XTRA, ZipCaddy, and ZipClip
viDTP T HWP 4K D Series Transmitters • Contents
Contents
Introduction............................................................ 1
About this Guide ................................................. 1
About the DTP T HWP 4K D Extenders .............. 1
Twisted Pair Cable Advantages ....................... 2
Transmission Distance .................................... 2
Features ............................................................. 3
Installation and Operation .................................. 4
Mounting the Transmitter or Receiver .................. 4
UL and Safety Guidelines ................................ 4
Site Preparation and Wall Box Installation ....... 4
Mud Ring Installation ...................................... 6
Final Installation .............................................. 7
Transmitter Front Panel ....................................... 7
Transmitter Rear Panel........................................ 8
TP Cable Termination and
Recommendations .......................................... 10
Power Supply Wiring ........................................ 11
RS-232 and IR Connector Wiring ..................... 13
Operation ......................................................... 14
Transmitter Power Indicator .......................... 14
System Operation ......................................... 14
Reference Information ...................................... 15
Decorator-Style Wallplate Template
Dimensions ..................................................... 15
DTP T HWP 4K D Series Transmitters • Introduction 1
Introduction
About this Guide
About the DTP T HWP 4K D Extenders
Features
About this Guide
This guide describes how to install, operate, and configure the Extron DTP T HWP 4K 231
D and DTP T HWP 4K 331 D models of High-Definition Multimedia Interface (HDMI™)
Extenders.
About the DTP T HWP 4K D Series Extenders
The Extron DTP T HWP 4K D Series extenders are HDMI transmitters (see figure 1) which
are housed in enclosures that can be mounted in Underwriters Laboratories (UL) standard
wall boxes with decorator-style face plates. A transmitter paired with a compatible receiver
extends the usable distance of HDMI digital video and RS-232, IR, or both control signals
over one shielded twisted pair (STP) cable up to 230 feet (70 meters) for the 231 D model
and 330 feet (100 meters) for the 331 D model.
HDMI IN
AUDIO IN
Tx Rx G Tx Rx
RS
-232
IR
OVER DTP
OUTPUTS
AUDIO
CATx Cable
up to 230' (70 m)
Extron
DTP T HWP 4K 231 D Tx
Transmitter
Extron
DTP HDMI 4K 230 D Rx
Receiver
RS-232
HDMI
HDMI
Blu-ray Player
Flat Panel
Display
Figure 1. A Typical DTP T HWP 4K D Point-to-Point Application
A DTP T HWP 4K D extender system consists of a transmitter (Tx) and a compatible
receiver (Rx). A typical system can handle a single HDMI digital video signal and a
bidirectional RS-232 or IR link. Each purchased transmitter is shipped with a single external
desktop 12 VDC power supply that accepts 100 to 240 VAC, 50-60 Hz input. A single
power supply connected to either the transmitter or a compatible receiver can power both
units through the twisted pair cable that links the units (see Power Supply Wiring on
page 11 for more information).
DTP T HWP 4K D Series Transmitters • Introduction 2
TLP 1000TV
IPCP 505
IN1608
DTP HDMI 4K 230 Rx
Projector
100-240V ~ -- A MAX
1
2
CONFIGURABLE
HDMI
HDMI
5
6
7
8
C
RS-232 IR
RS-232 IR
Tx Rx Tx RxG
Tx Rx Tx RxG
Tx Rx Tx RxG
HDMI
A
B
3
4
INPUTS
OUTPUTS
Tx Rx
RS-232
G
LAN
2x25W(8Ω)/2x50W(4Ω)
RESET
AUDIO INPUTS
OUTPUTS
REMOTE
LL1R R
L2
R
L
3
R
CLASS 2 WIRING
L4
R
L5R
+48V
+48V
12
LR
VARIABLE
IN1608 SA
2
MIC/LINE
L6
R
SIG LINK
DTP IN
SIG LINK
DTP IN
SIG LINK
DTP OUT
50/60 Hz
RS-232 IR
OVER DTP
OVER DTP
OVER DTP
AMPLIFIED OUTPUT
VOLUME
SCALING PRESENTATION SWITCHER
IN1608
INPUTS
1
HDCP
SIGNAL
OUTPUTS
ENTER
MENU
Extron
2 3 4 5 6 7 8 A B C
INPUTS
1 2 3 4 5 6 7 8
CONFIG
Extron
DTP T HWP 4K 231 D Tx
Transmitter
Ethernet
A Typical DTP T HWP 4K 231 D Application
Network
LR
POWER
12V
0.7A MAX
AUDIO
SIG LINK
DTP IN
OUTPUTS
XTP DTP 24 Cable
230 '
XTP DTP 24 Cable
230 '
HDMI
1 2345678
100
LINK
ACT
COM
IR/S
TX
RX
TX
RX
RTS
CTS
R
5
1
6
2
7
3
8
4
RELAY
FLEX
I/O
5
1
6
2
3
1
4
2
eBUS
ACT LIMIT
OVER
SWITCHED
12VDC
3
1
4
OVER
2
LIMIT
IR
7
3
8
4
IPCP 505
HDMI IN
AUDIO IN
Figure 2. A Typical DTP T HWP 4K D Application in a Larger System
Twisted Pair Cable Advantages
Twisted pair (TP) cable is much smaller, lighter, more flexible, and less expensive than
coaxial or HDMI cable. These transmitter TP products make cable runs simpler and
less cumbersome. Termination of the cable with RJ-45 connectors is simple, quick, and
economical (see TP Cable Termination and Recommendations on page 10 for more
information).
NOTE: Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201
cable to link the transmitter and receiver. The DTP T HWP 4K 231 D DTP T HWP 4K
331 D products do not work properly with these cables.
Control communications
The RS-232 or infrared (IR) communications are pass-through only. The transmitters do not
generate or respond to these signals.
Transmission Distance
The maximum transmission distance is determined by the resolution of the signal and the
twisted pair cable, graphics card, and display used in the system.
The DTP T HWP 4K 231 D transmitters and compatible receivers can transmit and
receive video signals of 720p, 1080i, and 1080p HDTV up to 230 feet (70 meters), and
UHD (3840x2160) @ 30 Hz or 4k (4096x2160) @ 30 Hz up to 130 feet (40 meters).
The DTP T HWP 4K 331 D transmitters and compatible receivers can transmit and
receive video signals of 720p, 1080i, 1080p HDTV, UHD (3840x2160) @ 30 Hz, or 4k
(4096x2160) @ 30 Hz up to 330 feet (100 meters).
DTP T HWP 4K D Series Transmitters • Introduction 3
Features
Transmits single link HDMI-D signals over one STP cable — Twisted pair cables
provide an economical, easily installed cable solution.
Supports DDC and HDCP transmission — The DTP T HWP 4K D transmitters fully
support long distance transmission of the DDC and HDCP signals.
Control communications pass-through — Bidirectional RS-232, IR, or both control
signals can be transmitted alongside the HDMI signal, so that the remote display can be
controlled without the need for additional cabling.
Audio routing — The DTP T HWP 4K D transmitters also route unbalanced stereo audio.
Supports CEC signal transmission
Wall-mountable enclosures
External 100 VAC to 240 VAC, 50-60 Hz, international power supply — Included with
transmitters.
Remote powering of the transmitter — Only one power supply is necessary to power a
transmitter and compatible receiver.
Supports computer video up to 1920x1200, HDTV 1080p @ 60 Hz with Deep Color,
UHD, and 4k resolutions.
DTP T HWP 4K D Series Transmitters • Installation and Operation 4
Installation and
Operation
This section describes the installation and the operation of the DTP T HWP 4K D Series
extenders, including:
Mounting the Transmitter
Transmitter Front Panel
Transmitter Rear Panel
TP Cable Termination and Recommendations
Power Supply Wiring
RS-232 and IR Connector Wiring
Operation
Mounting the Transmitter
ATTENTION:
Installation and service must be performed by authorized personnel.
L’installation et l’entretien doivent être effectués par le personnel autorisé
uniquement.
The DTP T HWP 4K D transmitters can be installed in a one-gang electrical wall box, or with
a mud ring, with a decorator-style wallplate cover (supplied).
The installation must conform to national and local building, electrical, and safety codes and
to the size requirements of the wall plate.
UL and Safety Guidelines
The following UL guidelines pertain to the installation of the decorator-style wallplate
transmitters into a wall or furniture.
These units are not to be connected to a centralized DC power source or used beyond
their rated voltage range.
These units must be installed in UL-listed wall boxes.
These units must be installed in a UL-listed junction box with a UL-listed faceplate.
This product is intended to be supplied by a power source marked “Class 2” or “LPS”
rated 12 VDC, minimum 1.0 A.
Site Preparation and Wall Box Installation
Choose a location that allows cable runs without interference. Allow enough depth for both
the wall box and the cables. Install the cables into the wall, furniture, or conduits before
installing the wall plate.
DTP T HWP 4K D Series Transmitters • Installation and Operation 5
NOTE: The decorator-style wallplate units are very deep and have connectors on the
back side. Extron recommends a 1-gang wall box which has a depth of at least 3.0
inches (7.6 cm) to accommodate the connectors and cables.
To install a new wall box, perform steps 1 through 9. If a suitable wall box is already
installed, perform steps 6 through 9, starting on the next page. UL-listed wall boxes are
recommended.
1. If a wall box is not available to use for a template, use the Decorator-Style Wallplate
Template Dimensions on page 15 to create a template. If installing directly into
furniture, cut out the center portion of the template.
2. Place the wall box (or the full-sized template) against the installation surface, and mark
the opening guidelines.
3. Cut out the material from the marked area.
4. Insert the wall box into the opening. The rear connectors on the box or wall plate should
fit easily into the opening. Enlarge or smooth the edges of the opening as required.
5. Secure the wall box with nails or screws, leaving the front edge flush with the outer wall
or furniture surface (see figure 3).
NOTES:
If attaching the wall box to wood, use four #8 or #10 screws or four 10-penny
nails. A minimum of 0.5 inch (1.3 cm) of screw thread must penetrate the
wood.
If attaching the wall box to metal studs or furniture, use four #8 or #10
self-tapping sheet metal screws or machine bolts with matching nuts.
Wall Stud
Screws
or Nails
Signal
Output
Cable
HDMI IN
AUDIO IN
Decorator-Style Faceplate
Extron
DTP T HWP 4K D
Transmitter
Figure 3. Installing the Wall Box and Mounting the Unit
DTP T HWP 4K D Series Transmitters • Installation and Operation 6
6. Feed the twisted pair cables and, if applicable, the power cables through the opening
and through the wall box punch-out holes, securing them with cable clamps to provide
strain relief.
NOTES:
In order to fit in the wall box, the twisted pair cables and RJ-45 connectors
should not have a boot installed.
One power supply can power both the transmitter and compatible receiver, so
only one unit needs a power supply (see Power Supply Wiring on page 11).
7. Trim back and insulate exposed cable shields with heat shrink to reduce the chance of
short circuits.
To prevent short circuits, the outer foil shield can be cut back to the point where the
cable exits the cable clamp.
8. Connect the cables to the rear of the unit.
9. Connect front panel devices (see Transmitter Front Panel on the next page for
connector details), restore the power supply, and test the transmitter and receiver
system. Make cabling adjustments before final installation, as the cables are
inaccessible afterwards.
Mud Ring Installation
1. Using the mud ring as a guide, mark the edges and cut out the material within the
marked area.
2. Insert the mud ring into the opening and rotate and secure the locking arms with the
supplied screws shown in figure 4.
3. Follow steps 6 through 9 of Site Preparation and Wall Box Installation above, and
Final Installation on the next page.
Wall
Wall Mounting
Bracket
Figure 4. Installing the Mud Ring
DTP T HWP 4K D Series Transmitters • Installation and Operation 7
Final Installation
After testing and making any adjustments, do the following:
1. At the power outlet, unplug the power supply.
NOTE: One power supply can power both the transmitter and compatible receiver
(see Power Supply Wiring on page 11).
2. Mount the transmitter into the wall box or mud ring, and attach the supplied decorator-
style faceplate to the unit (see figure 3 on page 5).
3. At the power outlet, reconnect the power supply. This powers up both units.
Transmitter Front Panel
HDMI IN
AUDIO IN
Extron
DTP T HWP 231/331 D
Front Panel
A
B
Figure 5. DTP T HWP 4K D Transmitter Front Panel Connectors
A HDMI input connector — Connect an HDMI cable between this port and the HDMI
output port of the digital video source.
B Audio input — Connect an unbalanced stereo audio source to this 3.5 mm mini stereo
jack. Figure 6 shows how to wire the audio plug.
Sleeve ( )
Ring
Right (
-
)
Tip
Left (+)
Figure 6. Audio Input Connector Wiring
NOTE: The units do NOT embed analog audio onto the HDMI signal. This analog
audio signal is transmitted simultaneously with audio embedded within the HDMI
signal.
DTP T HWP 4K D Series Transmitters • Installation and Operation 8
Transmitter Rear Panel
Tx Rx Tx Rx
RS-232 IR
G
HDBT
DTP
OVER TP
OUT
POWER
12V
A MAX
- -
DTP T HWP 231/331 D
Rear Panel
A
B
C
D
Figure 7. DTP T HWP 4K D Transmitter Rear Panel Connectors
A DC power input connector — Plug the included external 12 VDC power supply into
either this 2-pole connector (see Power Supply Wiring on page 11 to wire the power
connector) or the power input connector on a compatible receiver.
B Over TP connector — Connect a serial communications port to this 3.5 mm, 5-pole
captive screw connector for bidirectional RS-232 communication and bi-directional IR
(see RS-232 and IR connector wiring on page 13 to wire the connector).
C HDBaseT/DTP mode switch — Set this 2-position, recessed switch to configure
the output between HDBaseT and DTP modes. When configured for HDBaseT, use
an HDBaseT-compatible receiver. When configured for DTP, use a DTP-compatible
receiver.
NOTES:
When the unit is configured for DTP mode via the rear panel switch, the unit
can be powered either with the included external 12 VDC power supply, or
over the DTP line by a locally powered receiver or switcher. When configured
for HDBaseT mode, remote power capability is disabled, and the unit must be
powered locally.
When configured for DTP mode, HDMI video, digital embedded audio,
RS-232, IR, analog audio, and remote power are available when used with a
DTP-compatible receiving device.
When configured for HDBaseT mode, HDMI video, digital embedded audio,
RS-232, and IR are available when used with an HDBaseT-compatible
receiving device.
DTP T HWP 4K D Series Transmitters • Installation and Operation 9
D Transmitter output port — Connect one end of the twisted pair cable to the
RJ-45 connector on the transmitter (see TP Cable Terminations and
Recommendations on page 10 to properly wire the RJ-45 connectors).
ATTENTION:
Do not connect this device to a telecommunications or computer data
network.
Ne connectez pas ces appareils à des données informatiques ou à un réseau
de télécommunications.
DTP T HWP 4K D Series Transmitters • Installation and Operation 10
TP Cable Termination and Recommendations
Figure 8 details the recommended termination of both ends of TP cables with RJ-45
connectors in accordance with the TIA/EIA-T568B wiring standard.
5
Pin
1
2
3
6
7
8
4
Wire color
White-green
Green
White-orange
White-blue
Orange
White-brown
Brown
Blue
TIA/EIA T
568 B
TP Wires
12345678
Pins:
Figure 8. TP Cable Termination
NOTE: Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201
cable to link the transmitter and receiver. The DTP T HWP 4K D products do not work
properly with these cables.
Supported cables
The DTP T HWP 4K D Series of transmitters are compatible with shielded twisted pair
(F/UTP, SF/UTP, and S/FTP) cable.
Cable recommendations
Extron recommends using the following practices to reduce transmission errors and achieve
full transmission distances up to 230 feet (70 meters) for the 231 models and 330 feet
(100 meters) for the 331 models.
Use the following Extron XTP DTP 24 SF/UTP cables and DTP 24 connectors for the
best performance:
XTP DTP 24/1000 Non-Plenum 1000’ (305 m) spool 22-236-03
XTP DTP 24P/1000 Plenum 1000’ (305 m) spool 22-235-03
XTP DTP 24 Plug Package of 10 101-005-02
If not using XTP DTP 24 cable, at a minimum, Extron recommends 24 AWG, solid
conductor, STP cable with a bandwidth of at least 400 MHz.
Terminate cables with shielded connectors to the TIA/EIA-T568B standard.
Use no more than two pass-through points, which may include patch points, punch
down connectors, couplers, and power injectors. If these pass-through points are
required, use CAT 6 or 6a shielded couplers and punch down connectors.
NOTE: When using STP cable in bundles or conduits, consider the following:
Do not exceed 40% fill capacity in conduits.
Do not comb the cable for the first 20 meters, where cables are straightened,
aligned, and secured in tight bundles.
Loosely place cables and limit the use of tie wraps or Velcro
®
.
Separate twisted pair cables from AC power cables.
DTP T HWP 4K D Series Transmitters • Installation and Operation 11
Power Supply Wiring
NOTES:
Only one power supply is required. A single power supply connected to either unit
in the pair powers both units.
A power supply is included with each individually-packaged transmitter.
Do not tin the power supply leads before installing them in the direct insertion
connector. Tinned wires are not as secure in the connectors and could be pulled
out.
Figure 9 shows how to wire the connector. Snap the provided ferrite bead onto the DC
power cable between the power supply and the connector (see Transmitter Rear Panel
on page 8).
SECTION A–A
AA
Power Supply
Output Cord
Captive Screw
Connector
Ridges
Smooth
3/16"
(5 mm) Max.
Figure 9. Power Connector Wiring
CAUTION: The two power cord wires must be kept separate while the power supply is
plugged in. Remove power before wiring.
ATTENTION : Les deux cordons d’alimentation doivent être tenus à l’écart l’un de
l’autre quand l’alimentation est branchée. Couper l’alimentation avant de faire
l’installation électrique.
DTP T HWP 4K D Series Transmitters • Installation and Operation 12
ATTENTION:
Always use a power supply supplied and or specified by Extron. Use of an
unauthorized power supply voids all regulatory compliance certification and may
cause damage to the supply and the end product.
Utilisez toujours une source d’alimentation fournie ou recommandée par Extron.
L’utilisation d’une source d’alimentation non autorisée annule toute conformité
réglementaire et peut endommager la source d’alimentation ainsi que le produit
final.
The installation must always be in accordance with the applicable provisions of
National Electrical Code ANSI/NFPA 70, article 725 and the Canadian Electrical
Code part 1, section 16. The power supply shall not be permanently fixed to
building structure or similar structure.
Cette installation doit toujours être en accord avec les mesures qui s’applique
au National Electrical Code ANSI/NFPA70, article725, et au Canadian Electrical
Code, partie1, section16. La source d’alimentation ne devra pas être fixée de
façon permanente à une structure de bâtiment ou à une structure similaire.
Power supply voltage polarity is important. Incorrect voltage polarity can damage
the power supply and the unit. The ridges on the side of the cord (see figure 9)
identify the power cord negative lead.
La polarité de la source d’alimentation est primordiale. Une polarité incorrecte
pourrait endommager la source d’alimentation et l’unité. Les stries sur le côté du
cordon permettent de repérer le pôle négatif du cordon d’alimentation.
To verify the polarity before connection, plug in the power supply with no load and
check the output with a voltmeter.
Pour vérifier la polarité avant la connexion, brancher l’alimentation hors charge et
mesurer sa sortie avec un voltmètre.
The length of the exposed (stripped) copper wires is important.
The ideal length is 3/16 inch (5 mm). Longer bare wires can short together.
Shorter wires are not as secure in the connectors and could be pulled out.
La longueur des câbles exposés est primordiale lorsque l’on entreprend de les
dénuder. La longueur idéale est de 5mm (3/16inches). S’ils sont un peu plus
longs, les câbles exposés pourraient se toucher et provoquer un court circuit. S’ils
sont un peu plus courts, ils pourraient sortir, même s’ils sont attachés par les vis
captives.
Unless otherwise stated, the AC/DC adapters are not suitable for use in air
handling spaces or in wall cavities.
Sauf mention contraire, les adaptateurs AC/DC ne sont pas appropriés pour une
utilisation dans les espaces d’aération ou dans les cavités murales.
DTP T HWP 4K D Series Transmitters • Installation and Operation 13
RS-232 and IR Connector Wiring
Figure 10 shows how to wire the RS-232 and IR connector for the DTP T HWP 4K D units.
Do not tin the wires!
Controlling
Device
Ground (G)
Receive (Rx)
Transmit (Tx)
Ground (G)
Receive (Rx)
Transmit (Tx)
Bidirectional
FunctionPin
TX
RX
Gnd
Transmit data
Receive data
Signal ground
IR
Tx Rx G Tx Rx
RS-232
IR
Tx Rx G Tx Rx
Do not tin the wires!
RS-232
Figure 10. RS-232 and IR Connector Wiring
ATTENTION:
The length of the exposed (stripped) copper wires is important.
The ideal length is 3/16 inch (5 mm). Longer bare wires can short together. Shorter
wires are not as secure in the connectors and could be pulled out.
La longueur des câbles exposés est primordiale lorsque l’on entreprend de les
dénuder. La longueur idéale est de 5mm (3/16inches). S’ils sont un peu plus
longs, les câbles exposés pourraient se toucher et provoquer un court circuit. S’ils
sont un peu plus courts, ils pourraient sortir, même s’ils sont attachés par les vis
captives.
NOTE: Do not tin the wires before installing them in the direct insertion connector.
Tinned wires are not as secure in the connectors and could be pulled out.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23

Extron DTP T HWP 4K 331 D Manuel utilisateur

Catégorie
Prolongateurs AV
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues