12
WOLF GAS COOKTOPS
IMPORTANT NOTE:
The gas cooktop must be
connected to a regulated gas supply.
IMPORTANT NOTE:
This installation must
conform with local codes and ordinances.
IMPORTANT NOTE:
The natural gas cooktop
is rated for elevations up to 2438 m without
adjustment. Install a high altitude kit for eleva-
tions from 2438 to 3084 m. The LP gas cooktop
is rated for 3084 m.
The rating plate, located on the underside of
the burner box, has information on the type of
gas that should be used. If this information
does not agree with the type of gas available,
check with the local gas supplier.
EXPLOSION HAZARD—
Securely tighten all external gas
connections.
Failure to do so can result in explosion,
fire or death.
GAS SUPPLY REQUIREMENTS
Provide a gas supply line of 19 mm rigid pipe
to the cooktop location. A smaller size pipe on
long runs may result in insufficient gas supply.
Pipe joint compounds, suitable for use with LP
gas should be used. For LP gas, piping or
tubing size can be 13 mm minimum. LP gas
suppliers usually determine the size and mate-
rials used on the system.
If local codes permit, a flexible metal appliance
connector is recommended for connecting this
cooktop to the gas supply line. Do not kink or
damage the flexible connector when moving
the cooktop. You will need to determine the
fittings required, depending on the size of your
gas supply line, flexible metal connector and
shut-off valve.
If rigid pipe is used as a gas supply line, a
combination of pipe fittings must be used to
obtain an in-line connection to the cooktop. All
strains must be removed from the supply and
gas lines so the cooktop will be level and in
line.
IMPORTANT
NOTE
This installation
must conform with
local codes and
ordinances.
GAS RATING
Total Heat Electrical Types and
Output Gas Rating Appliance Pressures
Model # (Gas) Units (Watts) Category (mbar) Country of Destination
I2H G20 at 20
AT, DK, EE, FI, GR, IE, IT, LT,
ICBCT15G/S 6.8 kW 230
NO, PT, ES, SE, SI, SK, GB, CH
I2E G20 at 20 DE, PL
I2E+ G20 at 20/25 BE, FR
ICBCT15G/S-LP 494 g/h 230 I3P G31 at 37
BE, CZ, FR, GR, IE, NL, NO, PT,
ES, GB, CH
I2H G20 at 20
AT, DK, EE, FI, GR, IE, IT, LT,
ICBCT30G/S 14.7 kW 230
NO, PT, ES, SE, SI, SK, GB, CH
I2E G20 at 20 DE, PL
I2E+ G20 at 20/25 BE, FR
ICBCT30G/S-LP 1069 g/h 230 I3P G31 at 37
BE, CZ, FR, GR, IE, NL, NO, PT,
ES, GB, CH
I2H G20 at 20
AT, DK, EE, FI, GR, IE, IT, LT,
ICBCT36G/S 17.7 kW 230
NO, PT, ES, SE, SI, SK, GB, CH
I2E G20 at 20 DE, PL
I2E+ G20 at 20/25 BE, FR
ICBCT36G/S-LP 1287 g/h 230 I3P G31 at 37
BE, CZ, FR, GR, IE, NL, NO, PT,
ES, GB, CH