DMP 265LTE Series Cellular Communicator Guide d'installation

Taper
Guide d'installation
DESCRIPTION
Figure 1: 265LTE PCB
1INSTALL THE 265LTE
Caution: Touch grounded metal to discharge
static before handling the XTLplus.
1. Place the antenna onto the 265LTE SMA
connector and then twist the antenna until it
is securely tightened.
2. Slide the 265LTE into the XTLplus eight-
pin CELL MODULE connector, keeping the
265LTE parallel to the XTLplus.
3. Align the stando hole in the 265LTE with
the stando on the XTLplus, and then snap it
into place. See Figure 2.
The 265LTE Series Cellular
Communicator provides
a fully-supervised alarm
communication path over an
LTE network.
The 265LTE is installed on
the XTLplusTM and powered
by the panel so no additional
enclosure, power supply, or
battery back-up is needed.
Compatibility
XTLplus Series panels with
Version 212 and higher.
Figure 2: Installing the 265LTE
on the XTLplus
What is Included
265LTE Cellular
Communicator
External Antenna
RESETLOAD
BAT
PROG
R B
+ DC -
S
N
External
Antenna
SMA
Connector
Eight-Pin CELL MODULE
Connector
Stando
Hole
2ACTIVATE THE 265LTE
Cellular service is required before using the 265LTE
for signal transmission. The 265LTE comes ready for
activation with SecureComTM Wireless. Use Remote
LinkTM, the Dealer AdminTM site (DMPDealerAdmin.
com), the Tech APPTM, or call DMP Customer Service
(1-866-266-2826) to activate the 265LTE.
Remote Link Activation
1. Navigate to Remote Link and select a panel.
2. Select Program in the top menu and select
Communications from the drop-down
menu.
3. Select Cellular Network as the
Communication Type and click Activate.
4. Select SIM as the SIM Type.
5. Enter the SIM number found on the 265LTE
label and click Activate.
6. Select a Rate Plan for the 265LTE and click
Activate.
265LTE SERIES CELLULAR
COMMUNICATOR
Installation Guide
265LTE Series Installation Guide | Digital Monitoring Products, Inc 2
1. Navigate to the Dealer Admin site (DMPDealerAdmin.com).
2. Click Customers in the right-side menu and select a customer.
3. Click Add System.
4. Enter a System Name.
5. Select XTLplus from the System Type drop-down menu.
6. Select either Cellular or EASYconnect + Cell Backup in the Connection Type field.
7. Enter the SIM number found on the 265LTE label and click Get Status.
8. Enter the Account Number.
9. Select a Rate Plan for the 265LTE.
10. Click Activate Cellular Device.
3TEST THE 265LTE
Dealer Admin Activation
1. Navigate to the Tech APP.
2. Tap Find a Customer then search for a customer.
3. Tap Add a System.
4. Enter a System Name.
5. Scan or enter the Serial #.
6. Select XTLplus from the System Type drop-down menu.
7. Select either Cellular or EASYconnect + Cell Backup in the Connection Type field.
8. Enter the Account Number.
9. Enter the SIM number found on the 265LTE label then tap Get SIM Status.
10. Select a Rate Plan for the 265LTE.
11. Tap Activate Cellular Device.
Tech APP Activation
The panel provides a diagnostic function to test the communication integrity and cellular
signal strength of the 265LTE to the nearest tower for the cellular carrier. To use the
diagnostic function, reset the panel, enter 2313 (DIAG), and press CMD.
Communication Status
This option tests the individual components of cellular or wireless network communication.
1. Select CELL STATUS from the diagnostic menu. Possible test results are shown in
Table 1.
2. Select YES to continue through the remaining component tests or select NO to
stop testing and return to CELL STATUS.
Cellular Strength
This option provides a way to test the cellular signal strength of the nearest tower for the
cellular carrier. Follow the steps below to test the cellular strength of the 265LTE:
1. Select CELL SIGNAL from the diagnostic menu then press a select key or area.
2. SIGNAL: displays. The numerical value of the cell signal strength is represented
in -dBm. The bars represent the signal strength of the 265LTE and range from 0-7.
Zero bars indicate a weak signal and seven bars indicate a strong signal.
Confirmed Faulty
MODEM OPERATING NO MODEM FOUND
IDENTIFIED NO SIM CARD
TOWER DETECTED NO TOWER
REGISTERED NOT REGISTERED
CONNECT SUCCESS CONNECT ERROR
NOT ACTIVATED
CELL PATH GOOD NO ACK RECEIVED
Table 1: Communication Test Results
3 265LTE Series Installation Guide | Digital Monitoring Products, Inc.
FCC INFORMATION
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. this device must accept any interference received, including interference that may cause undesired
operation.
The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm
(7.874 in.) from all persons. It must not be located or operated in conjunction with any other antenna or
transmitter.
Changes or modifications made by the user and not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment o and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit dierent from that to which the receiver
is connected.
Consult the dealer or an experienced radio/TV technician for help.
Industry Canada Information
This device complies with Industry Canada Licence-exempt RSS standard(s). Operation is subject to the
following two conditions:
1. This device may not cause interference, and
2. this device must accept any interference, including interference that may cause undesired operation
of the device.
This system has been evaluated for RF Exposure per RSS-102 and is in compliance with the limits specified
by Health Canada Safety Code 6. The system must be installed at a minimum separation distance from the
antenna to a general bystander of 7.87 inches (20 cm) to maintain compliance with the General Population
limits.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de
licence. Lexploitation est autorisée aux deux conditions suivantes:
1. l’appareil ne doit pas produire de brouillage, et
2. l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
L’exposition aux radiofréquences de ce système a été évaluée selon la norme RSS-102 et est jugée conforme
aux limites établies par le Code de sécurité 6 de Santé Canada. Le système doit être installé à une distance
minimale de 7.87 pouces (20 cm) séparant l’antenne d’une personne présente en conformité avec les limites
permises d’exposition du grand public.
Designed, engineered, and
manufactured in Springfield, Missouri
using U.S. and global components.
INTRUSION FIRE ACCESS NETWORKS
2500 North Partnership Boulevard
Springfield, Missouri 65803-8877
888.436.7832 | DMP.com
© 2021 Digital Monitoring Products, Inc.
LT-1703 19083
Specifications
Primary Power 12VDC
Current Draw
Standby 13mA
Alarm 13mA
Ordering Information
265LTE-V
265LTE-A
Accessories
381-2 18" Coax Cable
381-12 12' Coax Extension
381-25 25' Coach Extension
383 Dual Band Antenna LTE (Included)
386 Antenna Mounting Bracket
Compatibility
XTLplus Series panels Version 212 and higher
Certifications
Cellular FCC Part 15: RI7CE910C1NV (Telit)
XMR201707BG96 (Quectel)
Industry Canada: 5131A-ME910C1NV (Telit)
10224A-201709BG96 (Quectel)
Intertek (ETL) Listed
ANSI/UL 985 Contol Units and Accessories,
Household System Type
(Residential Fire)
ANSI/UL 1023 Household Burglar Alarm
System Units (Residential
Burglary)
ANSI/UL 1610 Central Station Alarm Units
(Commercial Burglary)
ANSI/UL 1635 Digital Alarm Communicator
System Units (Commercial
Burglary)
265LTE SERIES CELLULAR
COMMUNICATOR
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

DMP 265LTE Series Cellular Communicator Guide d'installation

Taper
Guide d'installation