Landis Gyr M255 Mode d'emploi

Taper
Mode d'emploi
1
M255
Product FCC and IC
Compliance Manual
Publication: D3832, Rev AA
© Landis+Gyr 2021 | Proprietary + Confidential
2
Limitation on Warranties and Liability
Information in this document is subject to change without notice. This manual or any part of it thereof
may not be reproduced in any form unless permitted by contract or by written permission of Landis+Gyr.
In no event will Landis+Gyr be liable for any incidental, indirect, special, or consequential damages
(including lost profits) arising out of or relating to this publication or the information contained in it, even if
Landis+Gyr has been advised, knew, or should have known of the possibility of such damages.
Covered by both issued and pending patents.
For further patent information see: https://www.landisgyr.com/about/patent-notices/
© 2021 Landis+Gyr, Inc. | Proprietary + Confidential
Contact Us:
To provide feedback about this document, email us at [email protected]
Customer Support: 1-888-390-5733 | [email protected]
3
Introduction
M255 supports both single channel and frequency hopping RF communication modes. The
device has a two-way communication radio that complies to FCC Part 15.247, FCC Part 15.249,
and ISED Canada Radio Standards Specifications RSS-210 and RSS-247. Dimension of the board
is as shown in the figure below.
The M255 module is not commercially available as a standalone product for third-party
integration. It is intended for only Landis+Gyr series 5 residential gas products.
Figure 1. Board Dimension
4
a b
Figure 2. a) Bottom Side with RF Shield Lid Removed and b) Bottom Side with RF Shield Lid
Installed
In the figure below, the FCC ID, IC ID, and model name are shown as prints at the top of the
board.
Module Model: M255
FCC ID: R7PEC6R1X2
IC ID: 5294A-EC6R1X2
5
Figure 3. Top side with Antenna
Product Overview
This M255 is designed for Landis+Gyr series 5 gas product assemblies, which are assembled at a
contract manufacturer. Gas products are battery operated devices.
Figure 4. Products Containing the M255 PCBA
6
Federal Communications Commission (FCC)
Compliance Notice
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that
may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Consult Landis+Gyr or an experienced radio technician for help
Industry Canada (IC) Compliance Notice
This device complies with Industry Canada license-exempt RSS standard(s). Operation is
subject to the following two conditions: (1) this device may not cause interference, and (2)
this device must accept any interference, including interference that may cause undesired
operation of the device.
7
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1)
l'appareil e doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le
fonctionnement..
Under Industry Canada regulations, this radio transmitter may only operate using an
antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry
Canada. To reduce potential radio interference to other users, the antenna type and its gain
should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more
than that necessary for successful communication.
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut
fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour
l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage
adioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son
gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas
l'intensité nécessaire à l'établissement d'une communication satisfaisante.
RF Exposure Information
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with a minimum distance
of 20 cm between the radiator and your body. This transmitter must not be co-located or
operated in conjunction with any other antenna or transmitter.
Cet équipement est conforme aux limites FCC d'exposition aux radiations définies pour un
environnement non contrôlé. Cet équipement doit être installé et utilisé à une distance
minimale de 20cm entre le radiateur et votre corps. Cet émetteur ne doit pas être co-
implantés ou exploités en conjonction avec une autre antenne ou émetteur.
8
Host FCC and IC Label Requirement
On the final installation (e.g., on the enclosure of the final assembly) a label with the FCC and IC
information as shown in the figure below must be visible. The font size is to be four-points or
larger.
Figure 5. FCC and IC Label
Electrical Characteristics
Battery:
Battery chemistry: Lithium Manganese
Battery pack construction: 2 battery cells, size A, connected in parallel
Nominal voltage: 3.0 V
Capacity: 4800 mAh
DC Characteristics:
Operating Voltage Range: 2.4 V - 3.6 V
Typical Average Sleep Current (at 25°C): 2.2 µA
Radio Characteristics:
Typical Antenna Gain: 0 dBi ± 2dB
Frequency Range: 902.3 MHz 927.8 MHz
Modulation Format: 2-FSK, 2-GFSK
Transmit Output Power (typical)
o Single Channel Mode (Tools Connection): -3 dBm
9
o Frequency Hopping Mode
High Power: 27 dBm
Normal Power (default): 24 dBm
Receive sensitivity (typical)
o 9.6 kbps: -112 dBm
o 10 kbps: -112 dBm
o 19.2 kbps: -110 dBm
o 20 kbps: -110 dBm
o 38.4 kbps: -108 dBm
o 50 kbps: -108 dBm
o 150 kbps: -100 dBm
Max Input Power, No Damage: + 10 dBm
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

Landis Gyr M255 Mode d'emploi

Taper
Mode d'emploi

dans d''autres langues