Crafstman CMXGIAC2200 Le manuel du propriétaire

Catégorie
Groupes électrogènes
Taper
Le manuel du propriétaire
Inverter Generator
Instruction Manual | Guide D’utilisation | Manual de instructiones
CMXGIAC2200
IF YOU HAVE QUESTIONS OR COMMENTS, CONTACT US.
POUR TOUTE QUESTION OU TOUT COMMENTAIRE, NOUS CONTACTER.
SI TIENE DUDAS O COMENTARIOS, CONTÁCTENOS.
1-888-331-4569 WWW.CRAFTSMAN.COM
TABLE OF CONTENTS
INTRODUCTION AND SAFETY .............................1
Introduction .............................................................. 1
Safety Rules ............................................................... 1
Safety Symbols and Meanings ................................... 1
Exhaust and Location Hazards ................................... 2
Electrical Hazards ...................................................... 2
Fire Hazards ............................................................... 2
Standards Index ......................................................... 3
GENERAL INFORMATION AND SETUP .................4
Know Your Generator ................................................ 4
Emissions ................................................................... 5
Outlets ....................................................................... 6
Start Dial (Off/Run/Choke) ......................................... 6
USB Port .................................................................... 6
Eco Mode ................................................................... 6
Generator Status Lights ............................................. 6
Circuit Protectors ....................................................... 6
Remove Contents from Carton ................................... 7
Add Engine Oil ........................................................... 7
Fuel ........................................................................... 7
OPERATION ................................................... 9
Operation and Use Questions ......................................9
Before Starting Engine ...............................................9
Prepare Generator for Use ..........................................9
Grounding the Generator When In Use .......................9
Know Generator Limits ...............................................9
Transporting/Tipping of the Unit ..............................10
Starting Pull Start Engines ........................................10
Restarting Hot Engines .............................................11
Low Oil Level Shutdown System ...............................11
Charging a 12 VDC Battery ........................................11
Parallel Operation .....................................................11
MAINTENANCE AND TROUBLESHOOTING ..........12
Maintenance ............................................................12
Maintenance Schedule .............................................12
Preventive Maintenance ...........................................12
Engine Maintenance .................................................12
Storage .....................................................................14
Troubleshooting .......................................................16
WARNING: CANCER AND REPRODUCTIVE HARM
www.P65Warnings.ca.gov
. (000393a)
Owner’s Manual for Portable Generator 1
INTRODUCTION AND SAFETY
Introduction
Thank you for purchasing a CRAFTSMAN product. This
unit has been designed to provide high-performance,
efficient operation, and years of use when maintained
properly.
WARNING: Consult Manual. Read and under-
stand manual completely before using prod-
uct. Failure to completely understand manual
and product could result in death or serious
injury. (000100a)
If any section of the manual is not understood, contact
your nearest Service Dealer, or contact CRAFTSMAN at 1-
888-331-4569, or WWW.CRAFTSMAN.COM with any
questions or concerns.
The owner is responsible for proper maintenance and
safe use of the equipment. Before operating, servicing or
storing this generator:
Study all warnings in this manual and on the product
carefully.
Become familiar with this manual and the unit before
use.
Refer to the Assembly section of the manual for instruc-
tions on final assembly procedures. Follow the instruc-
tions completely.
Save these instructions for future reference. ALWAYS
supply this manual to any individual that will use this
machine.
The information in this manual is accurate based on
products produced at the time of publication. The man-
ufacturer reserves the right to make technical updates,
corrections, and product revisions at any time without
notice.
Safety Rules
The manufacturer cannot anticipate every possible cir-
cumstance that might involve a hazard. The warnings in
this manual, and on tags and decals affixed to the unit
are, therefore, not all inclusive. If using a procedure, work
method or operating technique that the manufacturer
does not specifically recommend, verify that it is safe for
others. Also make sure the procedure, work method or
operating technique utilized does not render the equip-
ment unsafe.
Throughout this publication, and on tags and decals
affixed to the generator, DANGER, WARNING, CAUTION
and NOTE blocks are used to alert personnel to special
instructions about a particular operation that may be
hazardous if performed incorrectly or carelessly. Observe
them carefully. Their definitions are as follows:
DANGER: Indicates a hazardous situation which,
if not avoided, will result in death or serious
injury.
WARNING: Indicates a hazardous situation
which, if not avoided, could result in death or
serious injury.
CAUTION: Indicates a hazardous situation
which, if not avoided, could result in minor or
moderate injury.
NOTE: Notes contain additional information important to a
procedure and will be found within the regular text of this
manual.
These safety warnings cannot eliminate the hazards that
they indicate. Common sense and strict compliance
with the special instructions while performing the
action or service are essential to preventing accidents.
Safety Symbols and Meanings
DANGER: Asphyxiation. Running engines pro-
duce carbon monoxide, a colorless, odorless,
poisonous gas. Carbon monoxide, if not
avoided, will result in death or serious injury.
(000103)
DANGER: Asphyxiation. The exhaust system
must be properly maintained. Do not alter or
modify the exhaust system as to render it
unsafe or make it noncompliant with local
codes and/or standards. Failure to do so will
result in death or serious injury. (000179b)
If you start to feel sick, dizzy, or weak after the generator
has been running, move to fresh air IMMEDIATELY. See a
doctor, as you could have carbon monoxide poisoning.
DANGER: Electrocution. Water contact with a
power source, if not avoided, will result in
death or serious injury. (000104)
DANGER: Electrocution. Turn utility and emer-
gency power supplies to OFF before connecting
power source and load lines. Failure to do so
will result in death or serious injury. (000116)
WARNING: Equipment and property damage. Do
not alter construction of, installation, or block
ventilation for generator. Failure to do so could
result in unsafe operation or damage to the
generator. (000146)
WARNING: Asphyxiation. Always use a battery
operated carbon monoxide alarm indoors and
installed according to the manufacturer’s
instructions. Failure to do so could result in
death or serious injury. (000178a)
WARNING: Equipment and property damage. Do
not operate unit on uneven surfaces, or areas
of excessive moisture, dirt, dust or corrosive
vapors. Doing so could result in death, serious
injury, property and equipment damage.
(000250)
DANGER
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is
a poison you cannot see or smell.
NEVER use inside a home
or garage, EVEN IF doors
and windows are open.
Only use OUTSIDE and
far away from windows,
doors, and vents.
2 Owner’s Manual for Portable Generator
WARNING: Moving parts. Keep clothing, hair,
and appendages away from moving parts. Fail-
ure to do so could result in death or serious
injury. (000111)
WARNING: Hot surfaces. When operating
machine, do not touch hot surfaces. Keep
machine away from combustibles during use.
Hot surfaces could result in severe burns or fire.
(000108)
WARNING: Personal injury. Do not insert any
object through the air cooling slots. Generator
can start at any time and could result in death,
serious injury, and unit damage. (000142a)
WARNING: Risk of injury. Do not operate or ser-
vice this machine if not fully alert. Fatigue can
impair the ability to service this equipment and
could result in death or serious injury. (000215)
WARNING: Injury and equipment damage. Do
not use generator as a step. Doing so could
result in falling, damaged parts, unsafe equip-
ment operation and could result in death or
serious injury. (000216)
WARNING: Equipment damage. Do not attempt
to start or operate a unit in need of repair or
scheduled maintenance. Doing so could result
in serious injury, death or equipment failure or
damage. (000291)
For safety reasons, it is recommended that the mainte-
nance of this equipment be performed by a Service
Dealer. Inspect the generator regularly, and contact the
nearest Service Dealer for parts needing repair or
replacement.
Exhaust and Location Hazards
DANGER: Asphyxiation. Running engines pro-
duce carbon monoxide, a colorless, odorless,
poisonous gas. Carbon monoxide, if not
avoided, will result in death or serious injury.
(000103)
DANGER: Asphyxiation. The exhaust system
must be properly maintained. Do not alter or
modify the exhaust system as to render it
unsafe or make it noncompliant with local
codes and/or standards. Failure to do so will
result in death or serious injury. (000179b)
WARNING: Equipment and property damage. Do
not alter construction of, installation, or block
ventilation for generator. Failure to do so could
result in unsafe operation or damage to the
generator. (000146)
WARNING: Asphyxiation. Always use a battery
operated carbon monoxide alarm indoors and
installed according to the manufacturer’s
instructions. Failure to do so could result in
death or serious injury. (000178a)
If you start to feel sick, dizzy, or weak after the generator
has been running, move to fresh air IMMEDIATELY. See a
doctor, as you could have carbon monoxide poisoning.
NEVER run a generator indoors or in a partly enclosed
area such as garages.
ONLY use outdoors and far away from windows, doors,
vents, crawl spaces and in an area where adequate ven-
tilation is available and will not accumulate deadly
exhaust gas.
Using a fan or opening a door will not provide sufficient
ventilation.
Point muffler exhaust away from people and occupied
buildings.
Electrical Hazards
DANGER: Electrocution. Contact with bare wires,
terminals, and connections while generator is
running will result in death or serious injury.
(000144)
DANGER: Electrocution. Water contact with a
power source, if not avoided, will result in
death or serious injury. (000104)
DANGER: Electrocution. In the event of electrical
accident, immediately shut power OFF. Use
non-conductive implements to free victim from
live conductor. Apply first aid and get medical
help. Failure to do so will result in death or seri-
ous injury. (000145)
The National Electric Code (NEC) requires the frame and
external electrically conductive parts of the generator be
properly connected to an approved earth ground. Local
electrical codes may also require proper grounding of
the generator. Consult with a local electrician for
grounding requirements in the area.
Use a ground fault circuit interrupter in any damp or
highly conductive area (such as metal decking or steel
work).
Once generator has been started outside, connect elec-
trical loads to extension cord(s) inside.
Fire Hazards
DANGER: Explosion and Fire. Fuel and vapors
are extremely flammable and explosive. Add
fuel in a well ventilated area. Keep fire and
spark away. Failure to do so will result in death
or serious injury. (000105)
DANGER: Explosion and Fire. Do not overfill fuel
tank. Fill to 1/2 inch from top of tank to allow
for fuel expansion. Overfilling may cause fuel
to spill onto engine causing fire or explosion
which will result in death or serious injury.
(000166b)
WARNING: Personal injury. Do not insert any
object through the air cooling slots. Generator
can start at any time and could result in death,
serious injury, and unit damage. (000142a)
WARNING: Fire risk. Fuel and vapors are
extremely flammable. Do not operate indoors.
Doing so could result in death, serious injury, or
property or equipment damage. (000281)
WARNING: Explosion and fire risk. Do not smoke
near unit. Keep fire and spark away. Failure to
do so could result in death, serious injury, or
property or equipment damage. (000282)
WARNING: Explosion and Fire. Do not smoke
while refueling unit. Failure to do so could
result in death, serious injury, or property or
equipment damage. (000284a)
Owner’s Manual for Portable Generator 3
Allow at least 5 feet of clearance on all sides of the gen-
erator when operating to prevent overheating and fire.
Do not operate the generator if connected electrical
devices overheat, if electrical output is lost, if engine or
generator sparks, or if flames or smoke are observed
while unit is running.
Keep a fire extinguisher near the generator at all times.
Standards Index
1. National Fire Protection Association (NFPA) 70: The
NATIONAL ELECTRIC CODE (NEC) available from
www.nfpa.org
2. National Fire Protection Association (NFPA) 5000:
BUILDING CONSTRUCTION AND SAFETY CODE
available from www.nfpa.org
3. International Building Code available from
www.iccsafe.org
4. Agricultural Wiring Handbook available from
www.rerc.org, Rural Electricity Resource Council P.O.
Box 309 Wilmington, OH 45177-0309
5. ASAE EP-364.2 Installation and Maintenance of Farm
Standby Electric Power available from
www.asabe.org, American Society of Agricultural &
Biological Engineers 2950 Niles Road, St. Joseph, MI
49085
6. CSA C22.2 100-14 Electric motors and generators for
installation and use, in accordance with the Rules of
the Canadian Electrical Code
7. ANSI/PGMA G300 Safety and Performance of Porta-
ble Generators. Portable Generator Manufacturers
Association, www.pgmaonline.com
This list is not all inclusive. Check with the Authority Hav-
ing Jurisdiction (AHJ) for any local codes or standards
which may be applicable to your jurisdiction.
4 Owner’s Manual for Portable Generator
GENERAL INFORMATION AND SETUP
Fig. A
See Fig. A and Fig. B.
Generator Components
Start Dial (Off/Run/Choke)
Eco Mode Switch
120V, 20A Outlet
Circuit Protector (if equipped)
Parallel Ports
Grounding Locations
1.5A, 5VDC USB Port
DC Outlet (battery charger)
Low Oil Warning
Overload Warning
AC Power Light
Carrying Handle
Fuel Tank Vent
Fuel Cap
Recoil Starter
Spark Arrestor
Muffler Cover
Service Door
Spark Plug Cover
Fig. B
Know Your Generator
WARNING: Consult Manual. Read and under-
stand manual completely before using prod-
uct. Failure to completely understand manual
and product could result in death or serious
injury. (000100a)
Replacement owner’s manuals are available at
WWW.CRAFTSMAN.COM.
002320
004707
15
19
13
14
12
17
16
18
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
004468
10 11
1
2
3
7
9
8
56
4
4
Owner’s Manual for Portable Generator 5
Emissions
The United States Environmental Protection Agency (US
EPA) (and California Air Resources Board (CARB), for
engines/equipment certified to California standards)
requires that this engine/equipment complies with
exhaust and evaporative emissions standards. Locate the
emissions compliance decal on the engine to determine
applicable standards. For emissions warranty informa-
tion, please reference the included emissions warranty. It
is important to follow the maintenance specifications in
the manual to ensure that the engine complies with the
applicable emissions standards for the duration of the
product’s life.
Product Specifications
Generator Specifications 2200i
Rated Power 1700 W
Starting Power 2200 W
Rated AC Voltage 120V
Rated AC Load at 120V 14.1 Amps**
Rated Frequency 60 Hz
Dimensions L x W x H (in/mm) 19.8 x 11.5 x 17.9 (504 x 293 x 454)
Weight (dry) 48 lb. (21.8 kg)
** Operating Temperature Range: -13 deg. C (8 deg. F) to 40 Deg. C (104 Deg. F). When operated above 25 deg. C
(77 deg. F) there may be a decrease in power.
** Maximum wattage and current are subject to, and limited by, such factors as fuel Btu content, ambient tempera-
ture, altitude, engine condition, etc.. Maximum power decreases about 3.5% for each 1,000 feet above sea level;
and will also decrease about 1% for each 6° C (10° F) above 16° C (60° F) ambient temperature.
Engine Specifications 2200i
Engine Type Single Cylinder, 4-stroke
Displacement 80 cc
Spark Plug Part Number 0K95530157
Spark Plug Type E6TC / E6RTC / BPR6HS or equivalent
Spark Plug Gap (in/mm) 0.024-0.028 (0.6-0.7)
Fuel Capacity / Type 4.5 L (1.18 U.S. gallons) / Unleaded
Oil Type See Add Engine Oil
Oil Capacity 0.35 L (0.36 qt.)
Run Time at 50% Load 7.0 Hours
* Go to WWW.CRAFTSMAN.COM or call 1-888-331-4569 for replacement parts.
6 Owner’s Manual for Portable Generator
Outlets
120 VAC, Duplex Outlet
See Fig. C. The 120 Volt outlet is overload protected by
the 15 Amp push button circuit protector. Each outlet
will power 120 Volt AC, single phase, 60 Hz electrical
loads requiring up to 1700 watts (1.7 kW).
Fig. C
Start Dial (Off/Run/Choke)
This controls the ON/OFF functions, choke and fuel valve
operation (Fig. D).
The OFF position stops the engine and shuts off fuel
flow.
The RUN position is for normal operation and to
gradually reduce the use of the choke.
The CHOKE position switches the fuel valve on to
start the engine.
NOTE: The CHOKE is not required to start a warm engine.
Fig. D
USB Port
The 5 VDC, 1.5 Amp USB outlet allows charging of com-
patible electronic devices.
Eco Mode
The economy switch has 2 modes of operation:
On: The quietest mode and best when running appli-
ances or equipment that are resistive loads (non-motor
starting), (example: TV, video game, light, radio).
Off: Best when running a both inductive (motor-start-
ing loads) and resistive (non-motor starting loads),
especially when these loads are turning on and off
(example: RV, air conditioner, hairdryer).
Generator Status Lights
See Fig. E.
Overload LED (orange): Indicates system overload
. During motor starting it is normal for the overload
LED to illuminate for a few seconds. If LED stays illumi-
nated and the ready LED turns off, the engine will con-
tinue to run without output power. Remove all applied
loads and determine if attached devices exceed recom-
mended output power. Check for faulty or shorted con-
nections. To restore electrical output, turn dial OFF to
reset. Start engine. If condition was corrected, the
orange LED will not illuminate and electrical output will
be restored. Loads can be applied once the green LED
illuminates. If the orange LED returns, contact an IASD.
Low Oil Level LED (red): Illuminates when oil level is
below safe operating level. Engine shuts down .
Power LED (green): Indicates output from generator
(unless there is a low oil or overload condition).
Fig. E
Circuit Protectors
The AC outlets are protected by an AC circuit protector.
The DC outlets are protected by a DC circuit protector. If
the generator is overloaded or an external short circuit
occurs, the circuit protector will trip. If this occurs, dis-
connect all electrical loads to determine the cause of the
problem before using the generator again. Reduce the
load if the circuit protector is tripped.
NOTE: Continuous tripping of the circuit protector may
cause damage to generator or equipment.
Push the button of the protector to reset the circuit pro-
tector.
000424
1
2
3
002347
2
1
3
2
1
3
002335
123
Owner’s Manual for Portable Generator 7
Remove Contents from Carton
1. Open carton completely by cutting each corner
from top to bottom.
2. Remove and verify carton contents prior to assem-
bly. Carton contents should contain the following:
Accessories
3. Call Customer Service at 1-888-331-4569 with the
unit model and serial number for any missing car-
ton contents.
4. Record model, serial number, and date of purchase
on front cover of this manual.
Add Engine Oil
CAUTION: Engine damage. Verify proper type
and quantity of engine oil prior to starting
engine. Failure to do so could result in engine
damage. (000135)
NOTE: The generator is shipped without oil in the engine.
Add oil slowly and verify oil level often during filling process
to ensure overfilling does not occur.
See Fig. F, Fig. G and Fig. H.
1. Place generator on a level surface.
2. Remove screws and side cover.
Fig. F
3. Clean area around oil fill and oil drain plug.
4. Remove oil fill cap and wipe dipstick clean.
Fig. G
5. Insert funnel into oil fill opening. Add recom-
mended engine oil as necessary. Climate deter-
mines proper engine oil viscosity. See chart to select
correct viscosity.
NOTE: Use petroleum based oil (supplied) for engine break-
in before using synthetic oil.
.
6. To check oil level, remove funnel and insert dipstick
into oil filler neck.
Fig. H
7. Remove dipstick and verify oil level is within safe
operating range.
NOTE: Verify oil level often during filling process to ensure
overfilling does not occur.
8. Install oil fill cap/dipstick and hand-tighten.
9. Replace side cover and screws.
Fuel
DANGER: Explosion and Fire. Fuel and vapors
are extremely flammable and explosive. Add
fuel in a well ventilated area. Keep fire and
spark away. Failure to do so will result in death
or serious injury. (000105)
Item Qty.
Inverter Generator 1
Owner’s Manual 1
Engine Oil 1
Oil Funnel 1
DC Charging Cable 1
Tool Kit 1
Product Registration Card 3
Service Warranty 1
Emissions Warranty 1
002542
SAE 30
10W-30
Synthetic 5W-30
000399
001792
8 Owner’s Manual for Portable Generator
DANGER: Explosion and Fire. Do not overfill fuel
tank. Fill to 1/2 inch from top of tank to allow
for fuel expansion. Overfilling may cause fuel
to spill onto engine causing fire or explosion
which will result in death or serious injury.
(000166b)
See Fig. I and Fig. J.
Fuel requirements are as follows:
Clean, fresh, unleaded gasoline.
Minimum rating of 87 octane/87 AKI (91 RON).
Up to 10% ethanol (gasohol) is acceptable.
DO NOT use E85.
DO NOT use a gas oil mix.
DO NOT modify engine to run on alternate fuels. Stabi-
lize fuel prior to storage.
1. Verify unit is OFF and cooled entirely prior to fueling.
2. Place unit on level ground in a well ventilated area.
WARNING: Explosion and Fire. Verify fuel cap
vent is set to ON for operation, and OFF for
transportation and storage. Failure to do so
could result in poor unit performance, death or
serious injury. (000362)
3. Clean area around fuel cap and turn vent on fuel cap
to ON.
Fig. I
4. Turn cap slowly to remove.
5. Slowly add recommended fuel. Do not overfill.
NOTE: Fill to red insert inside filler neck.
6. Install fuel cap.
7. Turn vent on fuel cap to OFF for transportation and
storage to avoid fuel spills.
Fig. J
NOTE: Allow spilled fuel to evaporate before starting unit.
IMPORTANT NOTE: It is important to prevent gum
deposits from forming in fuel system parts such as
the carburetor, fuel hose or tank during storage. Alco-
hol-blended fuels (called gasohol, ethanol or metha-
nol) can attract moisture, which leads to separation
and formation of acids during storage. Acidic gas can
damage the fuel system of an engine while in stor-
age. To avoid engine problems, the fuel system
should be emptied before storage of 30 days or lon-
ger. See the Storage section. Never use engine or car-
buretor cleaner products in the fuel tank as
permanent damage may occur.
001112
002543
Owner’s Manual for Portable Generator 9
OPERATION
Operation and Use Questions
Call Customer Service at 1-888-331-4569 with questions
or concerns about equipment operation and mainte-
nance.
Before Starting Engine
1. Verify engine oil level is correct.
2. Verify fuel level is correct.
3. Verify unit is secure on level ground, with proper
clearance and is in a well ventilated area.
Prepare Generator for Use
DANGER: Asphyxiation. Running engines pro-
duce carbon monoxide, a colorless, odorless,
poisonous gas. Carbon monoxide, if not
avoided, will result in death or serious injury.
(000103)
DANGER: Asphyxiation. The exhaust system
must be properly maintained. Do not alter or
modify the exhaust system as to render it
unsafe or make it noncompliant with local
codes and/or standards. Failure to do so will
result in death or serious injury. (000179b)
WARNING: Risk of fire. Do not use generator
without spark arrestor installed. Failure to do
so could result in death or serious injury.
(000118a)
WARNING: Asphyxiation. Always use a battery
operated carbon monoxide alarm indoors and
installed according to the manufacturer’s
instructions. Failure to do so could result in
death or serious injury. (000178a)
WARNING: Risk of Fire. Hot surfaces could ignite
combustibles, resulting in fire. Fire could result
in death or serious injury. (000110)
WARNING: Hot surfaces. When operating
machine, do not touch hot surfaces. Keep
machine away from combustibles during use.
Hot surfaces could result in severe burns or fire.
(000108)
CAUTION: Equipment and property damage.
Disconnect electrical loads prior to starting or
stopping unit. Failure to do so could result in
equipment and property damage. (000136)
Grounding the Generator When In
Use
The generator is equipped with an equipment ground
connecting the generator frame and the ground termi-
nals on the AC output outlets (see NEC 250.34 . This
allows the generator to be used as a portable without
grounding the frame of the generator as specified in
NEC 250.34 (Fig. K).
Neutral Floating
Fig. K
The generator (stator winding) is isolated from the frame
and from the AC outlet ground pin. Electrical devices
that require a grounded outlet pin connection will not
function if the outlet ground pin is not functional.
Know Generator Limits
Overloading a generator can result in damage to the
generator and connected electrical devices. Observe the
following to prevent overload:
Add up the total wattage of all electrical devices to be
connected at one time. This total should NOT be greater
than the generator's wattage capacity.
The rated wattage of lights can be taken from light
bulbs. The rated wattage of tools, appliances, and
motors can be found on a data label or decal affixed to
the device.
If the appliance, tool, or motor does not give wattage,
multiply volts times ampere rating to determine watts
(volts x amps = watts).
Some electric motors, such as induction types, require
about three times more watts of power for starting than
for running. This surge of power lasts only a few seconds
when starting such motors. Make sure to allow for high
starting wattage when selecting electrical devices to
connect to the generator:
1. Figure the watts needed to start the largest motor.
2. Add to that figure the running watts of all other
connected loads.
Wattage Reference Guide is provided to assist in deter-
mining how many items the generator can operate at
one time.
NOTE: All figures are approximate. See data label on appli-
ance for wattage requirements.
A
004468
A
10 Owner’s Manual for Portable Generator
Wattage Reference Guide
Transporting/Tipping of the Unit
Do not store or transport the unit at an angle greater
than 15 degrees.
Starting Pull Start Engines
WARNING: Recoil Hazard. Recoil could retract
unexpectedly. Kickback could result in death or
serious injury. (000183)
CAUTION: Equipment and property damage.
Disconnect electrical loads prior to starting or
stopping unit. Failure to do so could result in
equipment and property damage. (000136)
See Fig. L and Fig. M.
1. Turn fuel cap vent ON.
2. Rotate the Off/Run/Choke dial to CHOKE .
3. Switch Economy switch to OFF.
4. Firmly grasp recoil handle and pull slowly until
increased resistance is felt. Pull rapidly up and away.
Fig. L
5. When engine starts, rotate Off/Run/Choke dial to
RUN . Choke operation is reduced as Off/Run/
Choke dial is rotated towards RUN.
NOTE: If engine fires, but does not continue to run, rotate
the Off/Run/Choke dial to OFF and repeat starting instruc-
tions.
IMPORTANT: Do not overload generator or individual
panel outlets. If an overload occurs, the overload LED
will illuminate and AC output ceases. To correct,
see Generator Status Lights. Read Know Generator Limits
carefully.
Device Running
Watts
*Air Conditioner (12,000 Btu) 1700
*Air Conditioner (24,000 Btu) 3800
*Air Conditioner (40,000 Btu) 6000
Battery Charger (20 Amp) 500
Belt Sander (3") 1000
Chain Saw 1200
Circular Saw (6-1/2") 800 to 1000
*Clothes Dryer (Electric) 5750
*Clothes Dryer (Gas) 700
*Clothes Washer 1150
Coffee Maker 1750
*Compressor (1 HP) 2000
*Compressor (3/4 HP) 1800
*Compressor (1/2 HP) 1400
Curling Iron 700
*Dehumidifier 650
Disc Sander (9") 1200
Edge Trimmer 500
Electric Blanket 400
Electric Nail Gun 1200
Electric Range (per element) 1500
Electric Skillet 1250
*Freezer 700
*Furnace Fan (3/5 HP) 875
*Garage Door Opener 500 to 750
Hair Dryer 1200
Hand Drill 250 to 1100
Hedge Trimmer 450
Impact Wrench 500
Iron 1200
*Jet Pump 800
Lawn Mower 1200
Light Bulb 100
Microwave Oven 700 to 1000
*Milk Cooler 1100
Oil Burner on Furnace 300
Oil Fired Space Heater (140,000 Btu) 400
Oil Fired Space Heater (85,000 Btu) 225
Oil Fired Space Heater (30,000 Btu) 150
*Paint Sprayer, Airless (1/3 HP) 600
Paint Sprayer, Airless (hand-held) 150
Radio 50 to 200
*Refrigerator 700
Slow Cooker 200
*Submersible Pump (1-1/2 HP) 2800
*Submersible Pump (1 HP) 2000
*Submersible Pump (1/2 HP) 1500
*Sump Pump 800 to 1050
*Table Saw (10") 1750 to 2000
Television 200 to 500
Toaster 1000 to 1650
Weed Trimmer 500
* Allow 3 times the listed watts for starting these devices.
1
002347
2
1
3
2
A
Owner’s Manual for Portable Generator 11
Fig. M
.
Generator Shut Down
CAUTION: Equipment and property damage.
Disconnect electrical loads prior to starting or
stopping unit. Failure to do so could result in
equipment and property damage. (000136)
1. Shut off all loads and unplug electrical loads from
generator panel outlets.
2. Let engine run at no-load for several minutes to sta-
bilize internal temperatures of engine and genera-
tor.
3. Rotate Off/Run/Choke dial to OFF .
4. Turn fuel cap OFF.
Restarting Hot Engines
CAUTION: Equipment and property damage.
Disconnect electrical loads prior to starting or
stopping unit. Failure to do so could result in
equipment and property damage. (000136)
See Fig. L.
1. Turn Off/Run/Choke dial from STOP to RUN. This will
open the fuel valve and permit starting.
2. Firmly grasp recoil handle and pull slowly until
increased resistance is felt. Pull rapidly up and away.
Low Oil Level Shutdown System
The engine is equipped with a low oil level sensor that
shuts down the engine automatically when the oil level
drops below a specified level to prevent engine damage
. The engine will not run until the oil has been filled
to the proper level (Fig. M).
If the engine shuts down and there is sufficient fuel,
check engine oil level.
Charging a 12 VDC Battery
WARNING: Explosion. Batteries emit explosive
gases while charging. Keep fire and spark
away. Wear protective gear when working with
batteries. Failure to do so could result death or
serious injury. (000137a)
WARNING: Risk of burns. Batteries contain sulfu-
ric acid and can cause severe chemical burns.
Wear protective gear when working with bat-
teries. Failure to do so could result death or
serious injury. (000138a)
NOTE: A battery may lose some of its charge when not in
use for prolonged periods of time.
The DC charging output is not regulated. The circuit pro-
tector does not prevent over charging a battery. Battery
charging should be done in a dry location (Fig. N).
1. Start generator and turn Economy switch OFF.
2. Plug Battery Charging Cable into Battery Charger
Output jack, located on the control panel.
3. Connect positive (+) battery clamp (red wire) to
battery FIRST.
4. Connect negative (-) battery clamp (black wire) to
battery SECOND.
NOTE: This outlet can not recharge 6-volt batteries and can
not be used to crank an engine having a discharged bat-
tery.
Fig. N
WARNING: Environmental Hazard. Aways recy-
cle batteries at an official recycling center in
accordance with all local laws and regulations.
Failure to do so could result in environmental
damage, death or serious injury. (000228)
Parallel Operation
For output power up to 3230W, two inverters can oper-
ate in parallel using Parallel Kit (optional). See the Parallel
Kit Operator’s Manual or contact Customer Service at 1-
888-331-4569.
NOTE: All connections to the parallel kit should be made
while both inverters are turned off and all loads discon-
nected.
1. Make sure the Eco Mode Switch is in the same posi-
tion on both generators.
2. Make appropriate parallel connections to the out-
lets on each inverter as outlined in the owner’s
manual supplied with the kit.
NOTE: Do not disconnect any parallel kit connections once
the units are running.
3. Start both units per starting instructions. Once the
green output indicator illuminates, devices can be
connected and turned on using the parallel kit out-
let.
4. Follow Generator Shut Down instructions.
NOTE: For inverters, load applied to the parallel kit is not to
exceed 3230 watts due to a 5% power loss when parallel-
ing. See manual.
NOTE: Only use approved parallel kit.
002335
AB
3
B
004469
12 Owner’s Manual for Portable Generator
MAINTENANCE AND TROUBLESHOOTING
Maintenance
Regular maintenance will improve performance and
extend engine/equipment life. Contact Customer Ser-
vice at 1-888-331-4569, or WWW.CRAFTSMAN.COM to
find a dealer for maintenance work to be performed.
Regular maintenance, replacement or repair of the emis-
sions control devices and systems may be performed by
any repair shop or person of the owner’s choosing. How-
ever, to obtain emissions control warranty service free of
charge, the work must be performed by a CRAFTSMAN
service dealer. See the emissions warranty.
NOTE: Call 1-888-331-4569 with questions about compo-
nent replacement.
Maintenance Schedule
Follow maintenance schedule intervals, whichever
occurs first according to use.
NOTE: Adverse conditions will require more frequent service.
NOTE: All required service and adjustments should be each
season as detailed in the following chart.
Preventive Maintenance
Dirt or debris can cause improper operation and equip-
ment damage. Clean generator daily or before each use.
Keep area around and behind muffler free from combus-
tible debris. Inspect all cooling air openings on genera-
tor.
WARNING: Personal injury. Do not insert any
object through the air cooling slots. Generator
can start at any time and could result in death,
serious injury, and unit damage. (000142a)
Use a damp cloth to wipe exterior surfaces clean.
Use a soft bristle brush to loosen caked on dirt, oil, etc.
Use a vacuum to pick up loose dirt and debris.
Low pressure air (not to exceed 25 psi) may be used to
blow away dirt. Inspect cooling air slots and openings
on generator. These openings must be kept clean and
unobstructed.
NOTE: DO NOT use a garden hose to clean generator. Water
can enter engine fuel system and cause problems. If water
enters generator through cooling air slots, some water will
be retained in voids and crevices of rotor and stator wind-
ing insulation. Water and dirt buildup on generator internal
windings will decrease insulation resistance of windings.
Engine Maintenance
WARNING: Personal injury. Do not insert any
object through the air cooling slots. Generator
can start at any time and could result in death,
serious injury, and unit damage. (000142a)
WARNING: Accidental start-up. Disconnect spark
plug wires when working on unit. Failure to do
so could result in death or serious injury.
(000141)
Engine Oil Recommendations
To maintain the product warranty, the engine oil should
be serviced in accordance with the recommendations of
this manual. For your convenience, maintenance kits
designed and intended for use on this product are avail-
able from the manufacturer that include engine oil, oil
filter, air filter, spark plug(s), a shop towel and funnel.
These kits can be obtained by contacting Customer Ser-
vice at 1-888-331-4569.
At Each Use
Check engine oil level
Every 50 Hours
Clean/Replace Air Filter**
Change oil ?
Every 100 Hours or Every Season*
Replace Spark Plug
Clean Spark Arrestor
Valve Clearance Adjustment
Every 200 Hours or Every Season
Inspect/clean air cleaner filter**
Replace Fuel Filter +
? Change oil after first 30 hours of operation, then every
50 hours.
+ To be performed by a Service Dealer.
* Change oil every month when operating under heavy
load or in high temperatures.
** Clean more often under dirty or dusty operating con-
ditions. Replace air filter parts if they cannot be ade-
quately cleaned.
*** Check valve clearance and adjust if necessary after
first 50 hours of operation and every 100 hours
thereafter.
SAE 30
10W-30
Synthetic 5W-30
000399
Owner’s Manual for Portable Generator 13
Inspect Engine Oil Level
WARNING: Risk of burns. Allow engine to cool
before draining oil or coolant. Failure to do so
could result in death or serious injury. (000139)
See Fig. O and Fig. P. Inspect engine oil level prior to each
use, or every 8 hours of operation.
1. Place generator on a level surface.
2. Clean area around oil fill, and oil drain plug.
3. Remove oil fill cap and wipe dipstick clean.
Fig. O
4. To check oil level, insert dipstick into oil filler neck
without screwing it in.
Fig. P
5. Remove dipstick and verify oil level is within safe
operating range.
6. Add recommended engine oil as necessary.
NOTE: Verify oil level often during filling process to ensure
overfilling does not occur.
7. Replace oil fill cap and hand-tighten.
NOTE: Some units have more than one oil fill location. It is
only necessary to use one oil fill point.
Change Engine Oil
WARNING: Accidental start-up. Disconnect spark
plug wires when working on unit. Failure to do
so could result in death or serious injury.
(000141)
When using generator under extreme, dirty, dusty con-
ditions, or in extremely hot weather, change oil more fre-
quently (Fig. Q and Fig. R).
NOTE: Don’t pollute. Conserve resources. Return used oil to
collection centers.
Change oil while engine is still warm from running, as
follows:
1. Place generator on a level surface.
2. Remove screws and side cover.
Fig. Q
3. Disconnect the spark plug wire from the spark plug
and place the wire where it cannot contact spark
plug.
4. Clean area around oil fill and oil drain plug.
5. Remove oil fill cap and wipe dipstick clean.
6. Tip unit and drain oil completely into a suitable con-
tainer.
7. Once oil is sufficiently drained from unit, tip unit
back to a level position.
8. Insert funnel into oil fill opening. Add recom-
mended engine oil as necessary.
Fig. R
9. To check oil level, remove funnel and insert dipstick
into oil filler neck without screwing it in.
10. Remove dipstick and verify oil level is within safe
operating range.
NOTE: Verify oil level often during filling process to ensure
overfilling does not occur.
11. Replace oil fill cap and hand-tighten.
12. Wipe up any spilled oil.
13. Replace side cover and screws.
14. Properly dispose of oil in accordance with all appli-
cable regulations.
Air Filter
Engine will not run properly and may be damaged if run
with a dirty air filter. Service air filter more frequently in
dirty or dusty conditions (Fig. S).
To service air filter:
1. Remove screws and side cover.
2. Unscrew bolt and remove air filter cover.
3. Wash filter in soapy water. Squeeze dry in clean
cloth (DO NOT TWIST).
4. Clean air filter cover before installation.
5. Replace side cover and screws.
002404
001792
002542
002350
A
B
14 Owner’s Manual for Portable Generator
NOTE: To order a new air filter, contact the nearest autho-
rized service center at 1-888-436-3722.
Fig. S
Service Spark Plug
To service spark plug (Fig. T):
1. Remove spark plug cover.
2. Clean area around spark plug.
3. Remove and inspect spark plug.
4. Inspect electrode gap with wire feeler gauge and
reset spark plug gap to 0.6 - 0.7mm (0.024 - 0.028
in).
Fig. T
NOTE: Replace spark plug if electrodes are pitted, burned or
porcelain is cracked. Use ONLY recommended replacement
plug. See Product Specifications.
5. Install spark plug finger tight, and tighten an addi-
tional 3/8 to 1/2 turn using spark plug wrench.
Inspect Muffler and Spark Arrester
NOTE: It is a violation of California Public Resource Code,
Section 4442, to use or operate the engine on any forest-
covered, brush-covered, or grass-covered land unless the
exhaust system is equipped with a spark arrester, as defined
in Section 4442, maintained in effective working order.
Other states or federal jurisdictions may have similar laws.
Contact original equipment manufacturer, retailer, or
dealer to obtain a spark arrester designed for exhaust
system installed on this engine.
NOTE: Use ONLY original equipment replacement parts.
Inspect muffler for cracks, corrosion, or other damage.
Remove spark arrester, if equipped, inspect for damage
or carbon blockage. Replace parts as required.
Inspect Spark Arrester Screen (Fig. U)
WARNING: Hot surfaces. When operating
machine, do not touch hot surfaces. Keep
machine away from combustibles during use.
Hot surfaces could result in severe burns or fire.
(000108)
Clean Spark Arrestor Screen (Fig. U)
The engine exhaust muffler has a spark arrestor screen.
Inspect and clean the screen every 100 hours of opera-
tion or every season, whichever comes first.
To service spark arrestor:
1. Remove the clamp to remove retainer.
2. Slide spark arrestor screens out from the muffler
outlet tube.
3. Inspect screens and replace if torn, perforated or
otherwise damaged. Do NOT use a defective screen.
If screen is not damaged, clean with a commercial
solvent.
4. Replace the screens, and retainer, and secure with
clamp.
Fig. U
Valve Clearance
If uncomfortable about doing this procedure,
or the proper tools are not available, take gen-
erator to the nearest service center to have
valve clearance adjusted.
Check valve clearance after the first fifty-hours of opera-
tion. Adjust as necessary.
Intake — 0.10 ± 0.02mm (cold), (0.004" ± 0.001"
inches)
Exhaust — 0.10 ± 0.02mm (cold) (0.004" ± 0.001"
inches)
Storage
General
DANGER: Explosion and Fire. Fuel and vapors
are extremely flammable and explosive. Store
fuel in a well ventilated area. Keep fire and
spark away. Failure to do so will result in death
or serious injury. (000143)
WARNING: Risk of Fire. Verify machine has prop-
erly cooled before installing cover and storing
machine. Hot surfaces could result in fire.
(000109)
002351
BA
000211
002352
Owner’s Manual for Portable Generator 15
It is recommended to start and run the generator for 30
minutes, every 30 days. If this is not possible, refer to the
following list to prepare unit for storage.
DO NOT place a storage cover on a hot generator. Allow
unit to cool to room temperature before storage.
DO NOT store fuel from one season to another unless
properly treated.
Replace fuel container if rust is present. Rust in fuel will
cause fuel system problems.
Cover unit with a suitable protective, moisture resistant
cover.
Store unit in a clean, dry area.
Always store generator and fuel away from heat and
ignition sources.
Prepare Fuel System/Engine for Storage
Fuel stored over 30 days can go bad and damage fuel
system components. Keep fuel fresh, use fuel stabilizer.
If fuel stabilizer is added to fuel system, prepare and run
engine for long term storage. Run engine for 10-15 min-
utes to circulate stabilizer throughout fuel system. Ade-
quately prepared fuel can be stored up to 24 months.
NOTE: If fuel has not been treated with fuel stabilizer, it
must be drained into an approved container. Run engine
until it stops from lack of fuel. Use of fuel stabilizer in fuel
storage container is recommended to keep fuel fresh.
1. Change engine oil.
2. Remove spark plug.
3. Pour tablespoon (5-10cc) of clean engine oil or
spray a suitable fogging agent into cylinder.
WARNING: Vision Loss. Eye protection is required
to avoid spray from spark plug hole when
cranking engine. Failure to do so could result in
vision loss. (000181)
4. Pull starter recoil several times to distribute oil in
cylinder.
5. Install spark plug.
6. Pull recoil slowly until resistance is felt. This will
close valves so moisture cannot enter engine cylin-
der. Gently release recoil.
Change Oil
Change engine oil before storage. See, Change Engine
Oil.
16 Owner’s Manual for Portable Generator
Troubleshooting
PROBLEM CAUSE CORRECTION
Engine won't start.
1. Dial turned off.
2. Out of fuel.
3. Defective spark plug.
4. Plugged fuel filter.
5. Defective or stuck Dial assembly.
6. Incorrect engine oil level.
7. Defective ignition coil.
8. Fuel cap vent OFF.
9. Carb is flooded.
10. Throttle plate closed.
1. Turn on Dial.
2. Fill fuel tank.
3. Replace spark plug.
4. Replace fuel and fuel filter.
5. Contact Customer Service at 1-888-
331-4569.
6. Check/fill engine oil.
7. Contact Customer Service at 1-888-
331-4569.
8. Turn fuel cap vent ON.
9. Drain carb.
10. Open throttle plate (push toward
back of unit).
Engine starts, then shuts
down.
1. Out of fuel.
2. Incorrect engine oil level.
3. Contaminated fuel.
4. Defective low oil level switch.
5. Fuel cap vent OFF.
1. Fill fuel tank.
2. Check engine oil level.
3. Contact Customer Service at 1-888-
331-4569.
4. Contact Customer Service at 1-888-
331-4569.
5. Turn fuel cap vent ON.
Engine will not start; or
starts and runs rough.*
1. Choke is stuck or left on.
2. Dirty or clogged air filter.
3. Defective or dirty spark plug.
4. Dirty fuel filter.
5. Dirty or gummed up carburettor.
6. Unit not warmed up.
7. Fuel cap vent OFF.
8. Spark arrestor clogged.
1. Turn choke off.
2. Clean or replace air filter.
3. Replace spark plug.
4. Replace fuel and fuel filter.
5. Clean carburetor.
6. Gradually adjust Dial and reduce
choke until engine runs smoothly in
RUN position.
7. Turn fuel cap vent ON.
8. Clean spark arrestor.
No AC output.
1. Generator is overloaded.
2. Inverter module is overheated.
3. Short circuit in electrical device.
4. Defective inverter assembly.
1. Disconnect all loads. Shut down gen-
erator to reset module. Reduce loads,
restart generator.
2. Verify service door is ON. Let cool 15
minutes by running engine without
AC output. Press and hold Reset but-
ton on control panel, restart genera-
tor.
3. Verify condition of extension cords
and items being powered. Press and
hold Reset button on control panel.
4. Contact Customer Service at 1-888-
331-4569.
Fuel leaks from drain hoses.
1. Carburetor drain in bowl is not
closed.
1. Turn valve clockwise to close.
* Engine speed increases and decreases — This is normal as generator starts up and loads vary.
Craftsman, 701 East Joppa Road, Towson, MD 21286
Copyright © 2018
04/18 Part No. 10000031752 Rev. A
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

Crafstman CMXGIAC2200 Le manuel du propriétaire

Catégorie
Groupes électrogènes
Taper
Le manuel du propriétaire