Current Element L2000 Horticulture LED Lighting System Guide d'installation

Taper
Guide d'installation
(Rev 12/05/22) 99009251
HORT186 | DOC-2003849
Element® L2000
Horticulture LED Lighting System
HORT186 | DOC-2003849
EN For the latest European install guides and safety
information: https://www.gecurrent.com/eu-en/
indoor-lighting/horticulture-led-grow-lights
BG Българската версия на инструкциите за
инсталаця и информация за безопасност могат
да бъдат намерени на следния адрес: https://
www.gecurrent.com/eu-en/indoor-lighting/
horticulture-led-grow-lights
CS Návod k montáží a bezpečnostní informace v
češtině najdete zde: https://www.gecurrent.com/
eu-en/indoor-lighting/horticulture-led-grow-
lights
DA Den danske version af installationsvejledningen
og sikkerhedsoplysninger kan ndes på følgende
placering: https://www.gecurrent.com/eu-en/
indoor-lighting/horticulture-led-grow-lights
DE Die deutsche Version der Installationsanleitung
und Sicherheitsinformationen nden Sie in
folgendem Verzeic: https://www.gecurrent.com/
eu-en/indoor-lighting/horticulture-led-grow-
lights
EL Μπορείτε να βρείτε την ελληνική εκδχή των
οδηγιών νγκατάστασης και των πληροφοριών
ασφάλειας στην εξής τοποθεσία: https://
www.gecurrent.com/eu-en/indoor-lighting/
horticulture-led-grow-lights
ES La versión española de las instrucciones de
instalación y la información sobre seguridad
puede encontrarse en la siguiente ubicación:
https://www.gecurrent.com/eu-en/indoor-
lighting/horticulture-led-grow-lights
ET Eestikeelse paigaldusjuhendi ja ohutusnñuded
leiate aadressilt: https://www.gecurrent.com/eu-
en/indoor-lighting/horticulture-led-grow-lights
FI Asennusohjeiden ja turvallisuustietojen
suomenkielinen versio löytyy seuraavasta
paikasta: https://www.gecurrent.com/eu-en/
indoor-lighting/horticulture-led-grow-lights
FR La version française des instructions
d’installations et information de sécurité
est disponible à l’adresse suivante: https://
www.gecurrent.com/eu-en/indoor-lighting/
horticulture-led-grow-lights
HR Hrvatska verzija priručnika za ugradnju i
sigurnosnih informacija nalazi se na sljedečoj
lokaciji: https://www.gecurrent.com/eu-en/
indoor-lighting/horticulture-led-grow-lights
HU A telepítési útmutató és a biztnosági információk
magyar nyelvű változata az alábbi címen
található: https://www.gecurrent.com/eu-en/
indoor-lighting/horticulture-led-grow-lights
IT La versione italiana del manuale di installazione
e sicurezza può essere reperita nella seguente
sezione: https://www.gecurrent.com/eu-en/
indoor-lighting/horticulture-led-grow-lights
LT Lietuvišką diegimo instrukcijos ir saugos
informacijos versiją galima rasti šioje vietoje:
https://www.gecurrent.com/eu-en/indoor-
lighting/horticulture-led-grow-lights
LV Uzstādīšanas instrukciju un drošības informāciju
latviešu valodā var atrast šeit: https://www.
gecurrent.com/eu-en/indoor-lighting/
horticulture-led-grow-lights
NL De Nederlandse versie van de installatie-
instructies en veiligheidsinformatie kan op de
volgende locatie worden gevonden: https://
www.gecurrent.com/eu-en/indoor-lighting/
horticulture-led-grow-lights
PL Polską wersję instrukcji instalacji oraz informacje
dotyczące bezpieczeństwa można znaleźć w
następującej lokalizacji: https://www.gecurrent.
com/eu-en/indoor-lighting/horticulture-led-
grow-lights
PT A versão em Português das instruções de
instalação e das informações de segurança pode
ser encontrada na seguinte localização: https://
www.gecurrent.com/eu-en/indoor-lighting/
horticulture-led-grow-lights
RO Versiunea în limba românǎ a instrucţiunilor de
instalare şi a informaţiilor de siguranţǎ pot 
gǎsite la: https://www.gecurrent.com/eu-en/
indoor-lighting/horticulture-led-grow-lights
SV Ni hittar den svenska versionen
av installationsanvisningarna och
säkerhetsinformationen på följande plats: https://
www.gecurrent.com/eu-en/indoor-lighting/
horticulture-led-grow-lights
SL Previdnostna opozorila in varnostne informacije
so na zadnji strani vodnika za namestitev. Pred
začetkom namestitve izdelka jih skrbno preberite:
https://www.gecurrent.com/eu-en/indoor-
lighting/horticulture-led-grow-lights
SK Slovenskú verziu montažnej príručky a
bezpečnostnŷch instrukcií nájdete na
nasledujúcej lokalite: https://www.gecurrent.com/
eu-en/indoor-lighting/horticulture-led-grow-
lights
For the UL installation guide and safety information, please continue to page 2
Pour la version UL des instructions d’installations et information de sécurité, continuez à la page 2
2
Arize Element® L2000 Installation Guide
(Rev 12/05/22) 99009251
HORT186 | DOC-2003849
BEFORE YOU BEGIN / AVANT DE COMMENCER
Read these instructions completely and carefully. Lisez attentivement ces instructions dans leur intégrali.
For Commercial or Industrial use only.
DO NOT MAKE OR BREAK ELECTRICAL CONNECTION WHILE POWER IS APPLIED.
-10°C
35°C
Suitable for operation in an ambient temperature
between 14°F (-10°C) and 95°F (35°C).
A mechanical ventilation or cooling system is
required to maintain the temperature within the
growing space below 95°F (35°C) when the light
module is in operation.
Opération compatible avec un environnement à temperature
ambiante controlée entre 14°F (-10°C) et 95°F (35°C).
l’utilisation d’un système de contrôle de la température sera
nécessaire pour garder la serre sous les 95°F (35°C) lorsque le
luminaire est en function.
WARNING / AVERTISSEMENT
RISK OF ELECTRIC SHOCK
Turn power o before installation, inspection, cleaning or removal. And
follow appropriate lock out/tag out safety procedure.
Properly ground electrical enclosure.
Follow all National Electric Codes (NEC) and local codes.
This product must be installed in accordance with the applicable
installation code by a person familiar with the construction and
operation of the product and the hazards involved.
The installation and associated structures are subject to approval
by the authority having jurisdiction.
Use only with components identied in this document.
Suitable for dry, damp, and wet locations; Do not immerse any
component.
Wear suitable Personal Protective Equipment (PPE) during
installation/maintenance. Highly recommend safety glasses,
helmet and leather glove for luminaire mounting.
Luminaire design for Greenhouse only.
RISK OF FIRE
Minimum 24 inch distance from light module & driver to any
combustible material.
The light module shall be installed lens down with a minimum
60 inch distance to the oor.
All cables including connectors shall not be concealed or extended
through a wall, oor, ceiling, or other parts of the building structure;
located above a suspended ceiling or dropped ceiling; permanently
axed to the building structure.
Cables shall be routed so that they are not subject to strain and
are protected from physical damage; visible over their entire
length; and used within their rated ampacity as determined for
the maximum temperature of the installed environment specied
in the instructions.
For safe operation, and to maximize the longevity of the
luminaire; ensure that the light module and driver are clean and
free of dirt, dust, oil, or any other debris. Do not apply any kind
of lm on the lens or otherwise cover the driver or light engine
in any way.
RISQUE DE CHOC ELECTRIQUE
Coupez l’alimentation avant l’inspection, l’installation ou la désinstallation.
Reliez correctement le boîtier électrique à la mise à la terre.
Suivre tous les codes électriques locaux applicables.
Ce produit doit être installé selon le code d’installation pertinent,
par une personne qui connaît bien le produit et son fonctionnement
ainsi que les risques inhérents.
L’installation et les structures associées sont soumises à
l’approbation des autorités compétentes.
Utilisez uniquement avec les composants identiés dans ce document.
Convient aux endroits secs, humides et mouillés. Ne doit pas être immergé.
Portez les équipements de protection individuelle appropriés
pendant l’installation et la maintenance. L’utilisation de lunettes
de sécurité, d’un casque et des gants de cuir pour le montage du
luminaire est fortement recommandée.
Luminaire conçu pour serres seulement.
RISQUE D’INCENDIE
Distance minimale de 24 pouces entre l’équipement d’éclairage et
toute matière combustible.
Le luminaire doit être installé avec la lentille pointant vers le bas avec
une distance minimale de 60 pouces entre le luminaire et le sol.
Les câbles et connecteurs ne doivent pas être dissimulés à l’intérieur,
ou passer à travers, d’un mur, d’un plancher, d’un plafond ou de
toute autre partie de la structure du bâtiment; ne doivent pas être
placés au-dessus d’un plafond suspendu; ne doivent pas faire partie
intégrante de la structure du bâtiment.
Les câbles doivent être installés de façon à être protégés contre
l’étirement et tout autre bris physique; visibles sur toute leur
longueur; utilisés dans la limite de leur courant admissible,
déterminée pour les limites de température de l’environnement
spéciées dans le guide d’instruction.
Pour une opération sécurisée et pour maximiser la longévité
du luminaire; S'assurer que le module d'éclairage et le module
d'alimentation sont propres et sans saleté, poussière, huile ou
autres débris. Ne pas appliquer tout type de lm sur les lentilles et
ne pas couvrir le module d'alimentation ou le module d'éclairage de
quelconque manière.
3
Arize Element® L2000 Installation Guide
(Rev 12/05/22) 99009251
HORT186 | DOC-2003849
Luminaire Specications
Order Code Weight
System Input Current [A]
@ 277/347/480VAC
GEHE-M3PKT-5WN2-xx 14.5 kg (32 lbs) 3.6/2.9/2.2
GEHE-M3PKR-5WN2-xx 14.5 kg (32 lbs) 3.8/3.0/2.2
GEHE-T3PKF-5WN2-xx 14.5 kg (32 lbs) 3.4/2.7/2.0
GEHE-M3BRI-5WN2-xx 14.5 kg (32 lbs) 3.5/2.8/2.1
Components
1
2
4
3
5
Description Detailed Description
GECA60C16-OL04B AC Leader Cable, 4ft, UL
GECA60FNA-NL00B AC Field Installable Connector, UL and CE (Wieland P.N. 96.031.4155.7)
GECA30H20-OO03B Dimming cable, 3ft (914mm), UL and CE
Interconnection Cable Specications
Mounting Accessories Specications
Description Detailed Description Weight
GEMB-CBH1 18" (457mm) cable universal mounting kit 0.1 kg (0.2 lbs)
GEMB-CBH2 60" (1524mm) cable universal mounting kit 0.1 kg (0.2 lbs)
Arize Element® L2000
AC input leader cable
Light module brackets
1-5/8" (41mm) Wire Hangers
(included); or
Suspension cables (optional)
1
2
3
4
5
CAUTION / ATTENTION
Installation instructions and specications for
accessories can be found in the accessory package.
Les instructions d’installation et spécications pour les accessoires se
retrouvent dans le kit d’accessoires.
4
Arize Element® L2000 Installation Guide
(Rev 12/05/22) 99009251
HORT186 | DOC-2003849
Sample Installation Diagram
Unistrut
Light Fixture
Structure
AC line
Verify that all DC connectors are installed
and fully engaged. (Arrow on connector
locking ring should be facing up.)
DO NOT MAKE ANY CONNECTIONS WHILE
THE LUMINAIRE IS ENGERGIZED.
BEFORE INSTALLATION:
5
Arize Element® L2000 Installation Guide
(Rev 12/05/22) 99009251
HORT186 | DOC-2003849
1.1 Wire Hangers Unistrut 1-5/8" (41mm)
Use standard hanger 1-5/8" (41mm)
Place wire hangers over Unistrut. Attach light module brackets to luminaire.
Hang luminaire.
Wrap loop end of cable over
structural member. Insert
hook through loop end.
Attach hooks to light module brackets. Ensure hook gate is closed.
Loop
Hook
1.2 Universal Cables Other Structural Members
Use 18" (0.5m) or 60" (1.5m) universal cable
1 Installation of Luminaire
1 2
12
3
6
Arize Element® L2000 Installation Guide
(Rev 12/05/22) 99009251
HORT186 | DOC-2003849
2.2 Connect the Driver Input
CLICK!
2.1 Connect the AC InputDriver Connections
Select the correct AC input leader cable.
DC Output
Dimming
Amphenol P/N:
AD-03PMMS-QC8001 / Male
AC Input
Weiland P/N: 96.032.1055.7 / Male
Pin Line-to-Line
Voltage
Line-to-Neutral
Voltage
1 L2 L1 L1 L1 L2 L3
2 L3 L2 L3 N N N
PE PE PE PE PE PE PE
L=Line / N=Neutral / PE=Protective Earth
2 Electrical Connections
Leader cable to 4 ft.
open lead UL or CE
Align keying features on driver
with connector on the selected
leader cable.
Push connectors together until
a click is heard.
Recommended: secure AC
input leader cable.
1 2 3
NOTE: To
disassemble
connectors, insert
and twist a small
blade screwdriver
and then separate
connectors.
Connector pin-out
WARNING / AVERTISSEMENT
RISK OF ELECTRIC SHOCK
Turn power OFF before inspection, installation
or removal.
RISQUE DE CHOC ELECTRIQUE
Coupez l’alimentation avant l’inspection, l’installation ou la
désinstallation.
1
2
PE
>PA<
7
Arize Element® L2000 Installation Guide
(Rev 12/05/22) 99009251
HORT186 | DOC-2003849
2.3 Using Custom AC Inputs
AC line
To driver input
Connect the black wire to Line 1 and white wires to Neutral
or Line 2 of the incoming AC line. Care should be taken to
properly balance 3 phase loads. Connect the green wire to
the incoming ground conductor.
3 Connecting Wired Dimming (Optional)
NOTE: Arize L1000 dimming allows user to adjust the light output from 0%/10-100%. When set to 0%, the system will enter standby mode,
consuming 0.5-1.5W and LEDs may remain very faintly lit. If 0 light is preferred, switch o the unit via the mains (AC line).
Black
White
Green
Driver Input
Dimming
Cable
Purple
Black/White (12V)*
Pink
Dimming
Switch
+ (0-10V)
- (0-10V)
L1/L2/L3
N/L2/L3/L1
AC Line
If you choose to use your own custom AC input
connection, use a Wieland RST20i3 green connector
(96.031.4055.7 OR 96.031.4155.7 OR 96.031.0055.7
OR 96.031.1055.7) and plug into the male AC
connector of the driver.
2.4 Connecting Driver to AC Line
WARNING / AVERTISSEMENT
RISK OF ELECTRIC SHOCK
Turn power o before installation, inspection, cleaning or removal. And
follow appropriate lock out/tag out safety procedure.
This product must be installed in accordance with the applicable
installation code by a person familiar with the construction and
operation of the product and the hazards involved.
RISQUE DE CHOC ELECTRIQUE
Coupez l’alimentation avant l’inspection, l’installation ou la
désinstallation.
Ce produit doit être installé selon le code d’installation
pertinent, par une personne qui connaît bien le produit et son
fonctionnement ainsi que les risques inhérents.
Remove cap from dimming
connector.
Plug dimming cable: align
keying features and push
connectors together until lock
ring has snapped into place
and a click is heard. To remove
dimming cable, turn locking ring
1/8 of a turn counter-clockwise
and separate connectors.
Connect the appropriate wiring
to Dim + (0-10V) and Dim –
(0-10V) from driver. Insulate
the black wire. Follow dimming
switch instructions for rest of
connection.
*The black/white wire is a 12V
auxiliary output that can support
up to 250mA of current.
1 2 3
Arize Element® L2000 Installation Guide
Electrical products must not be thrown out with domestic waste. They must be taken to
a communal collecting point for environmentally friendly disposal in accordance with
local regulations. Contact your local authorities or stockist for advice on recycling. The
packaging material is recyclable. Dispose of the packaging in an environmentally friendly
manner and make it available for the recyclable material collection-service.
RISK GROUP 1 - NOTICE / AVERTISSEMENT - RAYONNEMENT LUMINEUX GROUPE 1
UV emitted from this product. Minimize exposure to eyes or skin. Use appropriate shielding.
Ce produit émet de la lumière UV. Minimiser l'exposition aux yeux ou à la peau. Utiliser les protections appropriées.
For the latest install guides for your product go to:
https://www.gecurrent.com/horticulture
Visit www.LED.com
Call us today! 1-888-694-3533
Email us:
arize.suppor[email protected]
These photobiological safety markings are based on testing of the light output characteristic of a single horticultural luminaire.
Increased exposure risk to facility personnel may be present depending upon the number of horticultural luminaires and their
placement and/or positioning within the plant growth facility.
It is the responsibility of the plant growth facility to address these risks at the facility level and to ensure that people entering the
plant growth areas while the lights are on, are aware of these risks and that appropriate safeguards are in place.
Ces avertissements de sécurité photobiologiques sont basés sur des tests du rendement lumineux d'un seul luminaire horticole.
Les employés risquent de sourir d'une exposition accrue selon le nombre de luminaires horticoles et leur placement et / ou
positionnement au sein de la serre / chambre de culture.
Il relève de la responsabilité de l'opérateur de l'installation de gérer les risques au niveau de l'installation et de s'assurer que les
personnes qui pénètrent dans les zones de croissance des plantes pendant que les lumières sont allumées soient conscientes des
risques et que des mesures de protection appropriées soient en place.
Save These Instructions
Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
This Class [A] RFLD complies with the Canadian standard ICES-005. /CeDEFR de la classe [A] est conforme à la NMB-005 du Canada.
gecurrent.com/arize
© 2022 Current Lighting Solutions, LLC. All rights reserved. Information and specications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 8 of 8
(Rev 12/05/22) 99009251
HORT186 | DOC-2003849
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Current Element L2000 Horticulture LED Lighting System Guide d'installation

Taper
Guide d'installation