DMP Electronics 1154 Guide d'installation

Taper
Guide d'installation
1154 WIRELESS FOUR-ZONE
INPUT MODULE
Installation Guide
Figure 1: 1154 Wireless Four-Zone
Input Module
The 1154 Wireless Four-Zone Input
Module is designed to convert up to
four existing normally closed, hardwired
zones (such as motion sensors, door
& window contacts, etc.) into wireless
zones.
When a DMP panel is installed in a
location with an existing non-DMP panel,
then the 1154 can be connected to the
existing panel’s 12V auxillary power.
Once connected, the 1154 Wireless Input
Module converts up to four existing
hardwired zones into wireless zones.
This allows the new DMP panel to
communicate with the existing zones.
Compatibility
All DMP 1100 Series Wireless Receivers
and burglary panels. See the last page
for compatibility details.
What is Included?
1154 Wireless Four-Zone Input
Module
3V Lithium CR123A battery
Hardware pack
1
PROGRAM THE PANEL
The 1154 can be programmed with up to four zones.
When programming the 1154 in the panel, refer to the
panel programming guide as needed.
1. In ZONE INFORMATION, enter the zone
number. Press CMD.
2. Enter the ZONE NAME and press CMD.
3. Once ZONE TYPE appears, select the
appropriate zone type. Press CMD.
4. At the NEXT ZONE prompt, select NO. If you
see the WIRELESS ZONE prompt, select YES.
Note: This option only displays if the zone
number can be programmed as wireless. This
option does not appear for hardwire zones.
5. Enter the eight-digit SERIAL NUMBER. Press
CMD.
6. Enter the CONTACT number being used.
7. Enter the SUPERVSN TIME and press CMD.
8. At the NEXT ZONE prompt, select YES and
continue to program up to three more zones.
Note: Zones must be entered sequentially. For
example, If you begin by programming zone 71,
program zone 72 as the next contact.
DESCRIPTION
2
MOUNT THE 1154
The 1154 should be placed close to the existing
non-DMP panel.
Mount the device on a flat surface such as a wall or
single-gang box. When using the optional Model 376L
plug-in power supply, mount the device near a wall
outlet. See Figure2 for mounting hole locations on
the housing base.
Figure 2: Mounting Hole Locations
Mounting Hole
2 1154 INSTALLATION GUIDE | DIGITAL MONITORING PRODUCTS
Option A: Power from an Existing Panel
Use power from an existing panel to connect the 1154 to powered zones such as PIRs or
glassbreak detectors. The existing panel must be connected to AC power. The powered zones
must be connected to the existing panel or another power supply for power.
1. Place the jumper on the two power source selector pins labeled EXT to enable external
power supply operation.
2. Using 18–22 gauge wire, connect a black wire to the ground terminal on the existing panel,
and a red wire to a terminal on the panel with 12VDC power. See Figure3.
3. Connect the black wire to the negative terminal on the input power terminal block on the
1154, and the red wire to the positive terminal.
4. Snap the housing cover into place.
+
+
_
Figure 3: Power from an Existing Panel
Existing Panel
AC
Power
Supply
Back-Up
Battery
GND
18–22
Gauge
Wire
Non-
Powered
Zone
Device 4
Non-
Powered
Zone
Device 3
Non-
Powered
Zone
Device 2
Non-
Powered
Zone
Device 1
Zone Wiring
Terminals
Input Power
Terminal
Block
Power Source
Selector Pins
GND
3V
Lithium
Battery
Wire the zones and connect the receiver before installing the battery or connecting a power
supply to the 1154.
1. Locate the existing contacts that you want to connect to the 1154. These contacts should be
within 100feet of the 1154.
2. Use 18–22 gauge wire to connect a zone device to terminals Z1+ and Z1-.
3. Repeat step2 for the remaining zones as needed.
Note: When wiring normally closed contacts, EOL resistors do not need to be changed or
removed.
3
WIRE THE 1154 ZONES
4
POWER THE 1154
1154 INSTALLATION GUIDE | DIGITAL MONITORING PRODUCTS 3
Option B: External DC Plug-In Power Supply
Use power from the optional Model 376L plug-in
DC power supply to connect the 1154 to powered
zones. The 1154 must be mounted near a wall
outlet or other power source.
1. Place the supplied jumper on the two power
source selector pins labeled EXT to enable
external power supply operation.
2. Connect the wiring from the power supply
to the input power terminal block. Connect
the black wire to the negative terminal and
the black and white wire to the positive
terminal. See Figure 4.
3. Plug the Model 376L power supply into a
110VAC outlet.
4. Snap the housing cover into place.
DC
Plug-in
Power
Supply
DC Power
2-position
Terminal Block
- +
- +
Black Wire
with White
Stripe
to Positive
Black Wire
to
Negative
Figure 4: DC Terminals to Plug-In Power Supply
Option C: External 12VDC Power Supply
Power the 1154 and powered zones from the DMP
Model505-12 power supply or other external 12VDC power
supply with battery backup to remove the existing non-DMP
panel from the setup. Use 18–22 gauge wire to connect the
1154.
1. Place the supplied jumper on the two power source
selector pins labeled EXT to enable external power
supply operation.
2. Observing the polarity of all wired connections,
use 18–22 gauge wire to connect the 1154's input
power terminal block to the + DC - terminal on the
505-12power supply. See Figure 5
3. Snap the housing cover into place.
Option D: Battery Power
Use a single CR123A 3V battery to connect the 1154 to non-
powered zones such as door or window contacts or battery-
powered contacts. Observe polarity when installing the
battery into the module.
Caution: Do not connect the 1154 to an external power
supply (existing panel, plug-in power supply, 505-12) if
there is a CR-123A 3V battery installed in the module.
1. If needed, remove the old battery and properly dispose
of it.
2. Place the supplied jumper on the two power source
selector pins labeled BAT to enable battery operation.
3. Place a new battery into the holder and observe
polarity.
4. Snap the housing cover into place.
Caution: Properly dispose of used batteries. Do not
recharge, disassemble, heat above 212°F (100°C), or
incinerate.
18–22
Gauge
Wire
505-12 Power
Supply
1154 Input Power
Terminal Block
+ DC -
- +
+ BAT —
Figure 5: External 12VDC Power Supply
Back-Up
Battery
Designed, engineered,
and manufactured in
Springfield, Missouri using U.S.
and global components.
LT-1619 18512
INTRUSION FIRE ACCESS NETWORKS
2500 North Partnership Boulevard
Springfield, Missouri 65803-8877
800.641.4282 | DMP.com
Compatibility
XT30 panels with 1100D Series Wireless Receiver
XT50 panels with integrated wireless receiver or 1100D Series
Wireless Receiver
XR150/XR550 Series panels with 1100X Series Wireless Receivers
XTLplus panels with integrated wireless receiver
XTLtouch panels with integrated wireless receiver
1100D/1100X Series Wireless Receiver Version 105 or higher
Patents
U. S. Patent No. 7,239,236
Certifications
FCC Part 15 Registration ID CCKPC0101
IC Registration ID 5251A-PC0101
1154 WIRELESS
FOUR-ZONE INPUT
MODULE
Specifications
Battery
Life Expectancy 3 years
Type 3V Lithium CR123A
Frequency Range 905-924 MHz
Dimensions 4.65”L x 3.1”W x 1.4”H
Color White
Housing Material Flame retardant ABS
Accessories
CR123 DMP 3V Lithium Battery
376L DC Plug-in Power Supply
505-12 12VDC Power Supply
FCC INFORMATION
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. this device must accept any interference received, including interference that may cause undesired operation.
The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm (7.874 in.) from
all persons. It must not be located or operated in conjunction with any other antenna or transmitter.
Changes or modifications made by the user and not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
1. Reorient or relocate the receiving antenna.
2. Increase the separation between the equipment and receiver.
3. Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
4. Consult the dealer or an experienced radio/TV technician for help.
Industry Canada Information
This device complies with Industry Canada Licence-exempt RSS standard(s). Subject to the following two conditions:
1. This device may not cause interference, and
2. this device must accept any interference, including interference that may cause undesired operation of the device.
This system has been evaluated for RF Exposure per RSS-102 and is in compliance with the limits specified by Health
Canada Safety Code 6. The system must be installed at a minimum separation distance from the antenna to a general
bystander of 7.87 inches (20 cm) to maintain compliance with the General Population limits.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence.
Lexploitation est autorisée aux deux conditions suivantes:
1. l’appareil ne doit pas produire de brouillage, et
2. l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible
d’en compromettre le fonctionnement.
Lexposition aux radiofréquences de ce système a été évaluée selon la norme RSS-102 et est jugée conforme aux limites
établies par le Code de sécurité 6 de Santé Canada. Le système doit être installé à une distance minimale de 7.87 pouces
(20 cm) séparant l’antenne d’une personne présente en conformité avec les limites permises d’exposition du grand
public.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

DMP Electronics 1154 Guide d'installation

Taper
Guide d'installation

dans d''autres langues