Thermador PALPKITHW5 Guide d'installation

Catégorie
Cuisinières
Taper
Guide d'installation
THERMADOR.COM
PALPKITHW and PALPKITHW5 Kits for Dual Fuel Pro Harmony
®
and Rangetop LP
Conversion and PAALTKITHW Kit for High Altitude Adjustment
Installation
INSTRUCTIONS
THERMADOR.COM
PALPKITHW and PALPKITHW5 Kits for Dual Fuel Pro Harmony
®
and Rangetop LP
Conversion and PAALTKITHW Kit for High Altitude Adjustment
Installation
INSTRUCTIONS
Table of Contents (English)................................................................2
Table de Matières (Français)............................................................19
Índice de Materias (Español)............................................................25
Models |
Modèles |
Modelos:
PRD304WHC/U
PRD305WHC/U
PRD364WDHC/U
PRD364WLHU
PRD366WHC/U
PRD484WCHU
PRD486WDHC/U
PRD486WLHU
PCG305W
PCG366W
PCG364WD
PCG364WL
PCG486WL
PCG486WD
Page. 2
This THERMADOR
®
appliance is made by
BSH Home Appliances Corporation
1901 Main Street, Suite 600
Irvine, CA 92614
Questions?
1-800-735-4328
www.thermador.com
We look forward to hearing from you!
Table of
CONTENTS
Safety ...................................................................................... 3
Important Safety Instructions.......................................... 3
Burner Conversion to LP Instructions ..................................... 5
Before You Begin............................................................ 5
Conversion Preparation .................................................. 5
Disassembling the Cooktop............................................ 5
LP Regulator Conversion ................................................ 6
Removing the Burner Orifices......................................... 7
Replacing the Burner Orifices......................................... 7
Reassemble the Cooktop................................................ 9
High Altitude Adjustment Instructions and
Setting Valve Screws for LP Converted Burners..................... 10
Setting Valve Screws....................................................... 10
Check for Gas Leaks ....................................................... 11
Checking manifold pressure ........................................... 11
Check Flame Characteristics........................................... 11
Conversion Label Placement .......................................... 12
Customer Support, Accessories & Parts....................back page
Install Scenarios
Safety
DEFINITIONS
WARNING
This indicates that death or serious injuries may occur as a
result of non-observance of this warning.
CAUTION
This indicates that minor or moderate injuries may occur as a
result of non-observance of this warning.
NOTICE: This indicates that damage to the appliance or
property may occur as a result of non-compliance with this
advisory.
Note: This alerts you to important information and/or tips.
Scenario
Complete
Pages
Natural gas with High Altitude adjustment 10 – 12
Natural gas to LP Conversion 5 – 9
Natural gas to LP Conversion with High Altitude
adjustment
5 – 12
Page. 3
Safety
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
Please Read Carefully
The LP Conversion Kit is used to convert THERMADOR
PROFESSIONAL
®
Rangetops and PRO HARMONY
®
Dual
Fuel Ranges, from natural gas to propane (LP) gas
operation. This kit cannot be used to convert older
models of THERMADOR PROFESSIONAL Rangetops or
Ranges other than those identified in these instructions
(see applicable models on the front cover). This kit cannot
be used to convert all-gas ranges, oven burners, or any
other brand of appliance.
Save the natural gas parts for possible conversion from LP
back to the natural gas in the future.
IMPORTANT: Only a qualified service technician or
installer should make this conversion.
INSTALLER: Please leave these instructions with this unit
for the owner.
OWNER: Please retain these instructions for future
reference.
CAUTION
Disconnect gas and electric power before making
conversion. Before turning power ON, be sure that all
controls are in the OFF position.
WARNING
This conversion kit shall be installed by a
qualified service agency in accordance with the
manufacturer’s instructions and all applicable
codes and requirements of the authority having
jurisdiction. If the information in these
instructions is not followed exactly, a fire,
explosion or production of carbon monoxide
may result causing property damage, personal
injury or loss of life. The qualified service
agency is responsible for the proper installation
of this kit. The installation is not proper and
complete until the operation of the converted
appliance is checked as specified in the
manufacturer’s instructions supplied with the
kit.
To the Service Agent:
It is important that you know the following BEFORE you
begin the gas conversion of the appliance.
Verify the type of gas supplied to the location. Ensure
that the appliance is connected to the type of gas for
which it is certified.
If the Dual Fuel range is to be converted for Propane
(LP) Gas, the appliance must first be converted for use
with Propane (LP) Gas before it can be converted for
use at high altitude. A Propane (LP) Conversion Kit is
available for purchase from Thermador Customer
Service. It is required that a Certified Professional
install the Propane (LP) Conversion Kit.
You must plan for sufficient time and resources to
perform the LP conversion process properly and
completely before leaving the job site. Every step
described in these instructions must be performed to
safely convert the appliance for proper operation on
Propane Gas. INCOMPLETE OR INADEQUATE GAS
CONVERSION OF THE APPLIANCE CAN CREATE A
SAFETY HAZARD.
State of California Proposition 65 Warning:
WARNING
This product can expose you to chemicals including
vinyl chloride, which is known to the State of California
to cause cancer and birth defects or other
reproductive harm. For more information go to
www.P65Warnings.ca.gov.
WARNING
If the Natural Gas orifices are left in place while
attempting to operate the appliance using Propane
(LP) Gas, at the higher pressure setting for LP Gas, the
burners will produce large flames which may emit high
levels of carbon monoxide into the room, or a fire or
explosion may occur.
WARNING
NEVER leave the gas conversion partially completed.
If the appliance is operated while the gas conversion is
incomplete, high levels of carbon monoxide may be
emitted, or a fire or explosion may occur.
Page. 4
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
For Massachusetts Installations:
1. Installation must be performed by a qualified or
licensed contractor, plumber or gas fitter qualified or
licensed by the state, province or region where this
appliance is being installed.
2. Shut-off valve must be a “T” handle gas cock.
3. Flexible gas connector must not be longer than 36''
(914 mm).
Page. 5
Burner Conversion to LP Instructions
Before You Begin
CAUTION
BEFORE PROCEEDING WITH THE CONVERSION,
SHUT OFF THE GAS SUPPLY TO THE APPLIANCE
PRIOR TO DISCONNECTING THE ELECTRICAL
POWER.
CAUTION
When connecting the unit to propane gas, make
certain the propane gas tank is equipped with its own
high pressure regulator. The maximum gas pressure to
this appliance is not to exceed 14.0 inches water
column from the propane gas tank regulator.
Tools Needed
Scissors
T-30 and T-20 Torx screwdriver
16 mm and 9 mm Hex head bits
1/4'' nut driver
7 mm or a 9/32” socket or wrench
Flat-head screwdriver, 1/8'' blade
LP Gas Conversion Kit Items Included
LP Conversion Preparation
1. Shut off the gas supply to the appliance prior to
disconnecting the electrical power.
2. Cut a 3/8'' long piece of the adhesive foam tape.
Place foam tape over the edge of the nut driver used
to replace the burner orifices, as shown below.
Disassembling the Cooktop
IMPORTANT: Ensure that the power is turned OFF at the
breaker and the gas supply is turned OFF.
1. Remove the cooktop grates and the burner caps.
2. Use a 16 mm Hex head bit for burners labeled ‘D’ or
‘F’. Use a 9 mm hex head bit for burners labeled ‘B’ to
remove the burner venturi from each burner base.
TIP: If a 16 mm hex head bit is not readily available, a
5/8'' hex bit can be selected. Alternatively, a bolt with
5/8'' head either “double-nutted” or tightened into
the chuck of a power driver can be used.
Description
PALPKITHW5
(305 models
only)
PALPKITHW
Foam Tape, 1" piece 1 1
Conversion Label 1 1
Burner Orifice 073 2
Burner Orifice 115 1 3
Burner Orifice 105 1 3
Burner Orifice 090 1
The foam tape helps to retain
the orifice in the end of the nut
driver so it will not fall inside
the appliance during orifice
removal or installation.
Page. 6
3. Disconnect the igniter. Carefully pull up on the burner
base.
4. Carefully remove each burner pedestal.
5. To facilitate the removal of the spill trays, depending
on model, remove the (3) or (4) T-20 Torx stainless
screws in the front face of the rear trim.
6. Remove the spill trays by rotating the trays up and out
the back.
7. Remove the heat shield, on some models. Some
models have a double-width shield that extends under
adjacent spill tray.
LP Regulator Conversion
The gas regulator is located in the cooktop, left side of
appliance. Exact location will vary per model.
3. Re-install conversion cap, configured for LP gas, back
into top of the regulator.
1) Burner Base 2) Electrode
3) Igniter Housing 4) Igniter Wire
1
2
3
4
1. Remove conversion
cap with a 7/8''
socket or wrench.
2. Read the letters on the stem. You will see “NAT” at
the bottom of the stem. Snap-out the plunger from
bottom of the conversion cap. Flip the stem over to
the “LP” end, and snap the plunger back into the
cap, as shown.
1) Brass Cap 2) Sealing Washer
3) Plunger 4) Regulator Body
LP
NAT
1
2
3
4
Page. 7
Removing the Burner Orifices
1. Use a 7 mm or a 9/32'' socket with 1/4'' nut driver to
reach down through the jet holders and remove the
Natural Gas orifice from the burner’s jet holder
Replacing the Burner Orifices
1. Locate the proper LP surface
burner orifices included with the
kit. Orifices are stamped with the
orifice diameter size on the side.
2. Replace each STAR burner jet orifice with the LP jet
orifices supplied in the kit per the following figures.
3. All of the replacement orifices in the conversion kit
have straight threads (not pipe threads) and do not
require thread sealing compound.
Model 304
BTU Rate LP Orifice size
(1) Natural 15000, LP 12000 BTU 105
(2) Natural 18000, LP 15000 BTU 115
(3) Natural 15000, LP 12000 BTU 105
(4) Natural 18000, LP 15000 BTU 115
44
11
22
33
Model 305
BTU Rate LP Orifice size
(1) Natural 8000, LP 6000 BTU 073
(2) Natural 18000, LP 15000 BTU 115
(3) Natural 10000, LP 9100 BTU 090
(4) Natural 8000, LP 6000 BTU 073
(5) Natural 15000, LP 12000 BTU 105
Model 364 with Griddle
BTU Rate LP Orifice size
(1) Natural 15000, LP 12000 BTU 105
(2) Natural 18000, LP 15000 BTU 115
(3) Not applicable
(4) Natural 15000, LP 12000 BTU 105
(5) Natural 18000, LP 15000 BTU 115
33
55
11
22
44
33
55
11
22
44
Page. 8
4. Perform a gas leakage test of each orifice and
associated supply tube fittings. See “Checking for
Gas Leaks” on page 11. Leak-checking should occur
after the orifice conversion is complete, and before
the burner is reassembled and tested.
Model 366
BTU Rate LP Orifice size
(1) Natural 15000, LP 12000 BTU 105
(2) Natural 18000, LP 15000 BTU 115
(3) Natural 15000, LP 12000 BTU 105
(4) Natural 18000, LP 15000 BTU 115
(5) Natural 15000, LP 12000 BTU 105
(6) Natural 18000, LP 15000 BTU 115
Model 364 with Grill
BTU Rate LP Orifice size
(1) Natural 15000, LP 12000 BTU 105
(2) Natural 18000, LP 15000 BTU 115
(3) Not applicable
(4) Natural 15000, LP 12000 BTU 105
(5) Natural 18000, LP 15000 BTU 115
33
44
66
11
22
55
33
55
11
22
44
Model 486 with Grill
BTU Rate LP Orifice size
(1) Natural 15000, LP 12000 BTU 105
(2) Natural 18000, LP 15000 BTU 115
(3) Natural 15000, LP 12000 BTU 105
(4) Natural 18000, LP 15000 BTU 115
(5) Not applicable
(6) Natural 15000, LP 12000 BTU 105
(7) Natural 18000, LP 15000 BTU 115
Model 486 with Griddle
BTU Rate LP Orifice size
(1) Natural 15000, LP 12000 BTU 105
(2) Natural 18000, LP 15000 BTU 115
(3) Natural 15000, LP 12000 BTU 105
(4) Natural 18000, LP 15000 BTU 115
(5) Not applicable
(6) Natural 15000, LP 12000 BTU 105
(7) Natural 18000, LP 15000 BTU 115
33
44
77
11
22
66
55
33
44
77
11
22
66
55
Page. 9
Reassemble the Cooktop
1. Reinstall the heat shield, if applicable.
2. Reinstall the spill trays.
3. Reinstall the Flush Island Trim with T-20 Torx screws.
4. Reinstall the burner pedestals.
5. Set the burner bases back on the burner pedestals.
6. Use a 16 mm Hex head bit for burners labeled ‘D’ or
‘F’. Use a 9 mm hex head bit for burners labeled ‘B’ to
secure the burner venturi to each burner base.
TIP: If a 16 mm hex head bit is not readily available, a
5/8'' hex bit can be selected. Alternatively, a bolt with
5/8'' head either “double-nutted” or tightened into
the chuck of a power driver can be used.
7. Replace burner caps and grates.
Page. 10
High Altitude Adjustment Instructions and
Setting Valve Screws for LP Converted Burners
High Altitude
This appliance has been tested for operation up to an
altitude of 10,100 ft (3078 m) elevation above sea level.
For altitudes above 2,000 feet (610 m) elevation above sea
level, adjustments can be made with the High Altitude
Packet. If flame performance is satisfactory, the contents
in this packet will not be required. It is required that a
Certified Professional make the high altitude adjustments
during installation.
Propane (LP) Gas Appliances – If the appliance is to be
adjusted for high altitude and also converted to Propane
(LP) gas, the appliance must first be converted for use with
LP before it can be adjusted for use at high altitude.
Setting Valve Screws
1. SHUT OFF THE GAS SUPPLY TO THE APPLIANCE.
2. DISCONNECT THE ELECTRICAL POWER.
3. Remove knob from the valve stem by slowly pulling
knob straight out, away from the control panel.
5. To engage the valve screw, insert the included flat-
blade screwdriver with 1/8'' blade into the hole in the
bezel created by removal of the mounting screw.
Access to the valve screws through clearance hole in
the spark module. You should feel the engagement of
the screwdriver and the valve screw.
6. FOR STANDARD BURNERS, adjust the valve screw by
turning the valve screw clockwise about an
1/8 turn. Adjust the valve screw as little as required to
reach satisfactory simmer results. Due to normal
fluctuations in gas pressure, over-adjustment of valve
screw may affect flame stability.
FOR EXTRALOW BURNERS, auto-cycling of the
XLOW burners allows for exceptional simmer results
and adjustment is not required. However, adjustment
to the valve screw may be performed to suit individual
preference.
A flat-head screwdriver with an
1/8" [3.0 mm] wide, .020"
[0.50 mm] thickness tip
(included) is used to reposition
the valve screws for minimum
flow settings on manual valves.
4. Remove the bezel-mounting
screw located to the right of
the valve stem, using a T-20
Torx driver.
Page. 11
Checking for Gas Leaks
WARNING
DO NOT use a flame of any kind to check for gas
leaks.
WARNING
Leak-checking should occur after the orifice
conversion is complete, and before the burner is
reassembled and tested.
1. Make sure that all of the LP orifices have been
tightened and that all valves and controls are in the
OFF position.
2. Turn ON electrical and gas supplies.
3. Spray a generous amount of soap and water
mixture—or other solution designed for checking
gas leaks—on the threaded junction at the base of
the orifice. Avoid spraying electrical devices. (A
25% dishwashing liquid to water mixture is
effective for this.)
4. Briefly turn on the valve or control while blocking
the orifice hole with a soft pencil eraser, your
finger, or something similar. It is normal to hear
spark ignition noise during this process.
5. Monitor the base of the orifice junction to see if
bubbles are forming anywhere around the
threaded connection. Bubbles forming are
indications of gas leaks. The amount and sizes of
the bubbles are indications of the severity of the
leakage.
6. Repair all gas leaks immediately after their
discovery; this can often be accomplished by re-
tightening the orifice.
7. Since considerable torque is sometimes used
during orifice replacement, leak-check other fitting
junctions leading up to the orifice as well.
8. Turn off the gas and electrical supplies.
9. Reassemble the appliance in preparation for
testing the newly-converted burner systems.
Checking manifold pressure
Checking the appliance manifold pressure is NOT
REQUIRED for the Propane Gas conversion; however, if
the outlet pressure of the gas regulator or the inlet
pressure to the appliance is suspect, the following
procedure can be used to check the manifold pressure.
2. Turn on the electrical and gas supplies to the
appliance.
3. Turn one of the cooktop burners to HI position. This is
important to acquire a true pressure reading under
gas flow conditions.
4. Turn the manual valve for the burner being monitored
to HI position. (Spark ignition noise will be heard
coming from this burner.)
5. The manifold pressure reading on the manometer
should be between 9.50" and 10.50" WC for an
appliance regulator converted to LP gas. If the
manifold pressure reading is below this range, verify
that the regulator has been properly converted for use
with LP gas, and that the inlet pressure to the
appliance is between 11.0" and 14.0" WC.
Check Flame Characteristics
To observe the burner flames, it may be necessary to turn
off lights or close window blinds to darken the room for
easier viewing of the flame.
1. Test STAR
®
burner ignition. Push in the burner control
knob and turn it to HI. The igniter electrode and spark
module will produce a clicking sound. Once the air has
been purged from the supply lines, the burner should
light within four seconds.
The flames should be stable, with no excessive
noise. The inner cones of the individual flames
should be defined and separate from each other.
Portions of the flame, along the burner, should not
exhibit excessive or continuous indications of
“lifting” or “lazy flame”.
1. Attach a portable or
hand-held manometer,
that reads pressure in
inches water column
(WC), using a piece of
PVC or vinyl tubing.
Page. 12
NOTE: It is normal for slight yellow tipping of the flames
to appear after a few minutes of operation using Propane
(LP) Gas. Orange-colored streaks in the flame are
produced from burning airborne debris; this is normal
during initial start up and should dissipate within a few
minutes of operation.
2. Turn valve to SIM to see that the flame continues to
wrap around the burner. Blow out the flame, or use a
quick fan motion from a writing tablet or piece of
cardboard to extinguish the flame, and then observe
the burner’s ability to reignite and wrap around (also
called carry-over”) the burner within several seconds.
This flame “carry-over” is essential for proper burner
ignition and re-ignition.
3. Test re-ignition of the XLO and observe the carry-over
of the small simmer flames as the XLO system cycles
the burners on and off.
If the flame performance is not acceptable it may
be necessary to readjust the valve screw for a top
burner that does not have sufficient carry-over of
the flame. Turn the valve screw very slightly
counter-clockwise until carry-over of the flame is
acceptable. (See Setting Valve Screws for the
Burners).
If the burner flame is uneven, flutters, makes
excessive noise, or lifts, some of the slots in the
burner base may be blocked with food spillage or
other debris. Clogged slots can be cleared using a
straightened paper clip, needle, or similar object.
Hard-to-remove, encrusted food or debris can
sometimes be removed using a steel wool pad or
fine wire brush.
4. Burner flames that are “lazy”, with excessively-long
flames, can be created by an incorrectly fitted burner
cap—from which many of the outer mantles of the
individual flames will tend to “coalesce” or blend
together.
Verify that the burner cap is seated properly on its
burner base. The cap should fit reasonably flat when
correctly-positioned on the base and not rock
significantly.
5. Repeat the Ignition and Flame Test procedures for
each burner.
Conversion Label Placement
1. For proper identification and evidence of the
appliance’s conversion for high-altitude operation,
affix the provided Conversion Label in a location next
to the Rating Labels on the appliance.
2. After placing the Conversion Label, use a permanent
marker to fill-in the date, name, and address of your
service organization on the Conversion Label.
Yellow Flames:
Further adjustment is
required.
Yellow Tips on Outer Cones:
Normal for LP Gas
Soft Blue Flames:
Normal for Natural Gas
Correct burner cap Incorrect burner cap
Page. 13
Cet appareil électroménager de THERMADOR
TM
est fait par BSH Home Appliances LtD
6696 Financial Drive, Unit 3
Mississauga, ON L5N 7J6
Des questions?
1-800-735-4328
www.thermador.ca
Nous attendons de vos nouvelles!
Table des
MATIÈRES
Sécurité .................................................................................. 14
Importantes Consignes de Sécurité................................ 14
Instructions de Conversion Au GPL........................................ 16
Avant de commencer...................................................... 16
Préparation conversion ................................................... 16
Comment démonter la surface de cuisson ..................... 16
Conversion d’un régulateur ............................................ 17
Remplacement des orifices des brûleurs........................ 18
Comment remonter la surface de cuisson...................... 20
Instructions d’ajustement des vis des soupapes des brûleurs
convertie pour utilisation de GPL en haute altitude............... 21
Réglage des vis de la soupape manuelle........................ 21
Inspection des fuites de gaz ........................................... 22
Vérification de la pression d’admission (si nécessaire) .. 22
Vérification des caractéristiques de la flamme ............... 23
Pose de l’étiquette de conversion au LP ........................ 24
Entretien, pièces et accessoires................................page verso
Types d'installation
Définitions de
SÉCURITÉ
AVERTISSEMENT
Ceci indique que le non respect de cet avertissement peut
entraîner des blessures graves, voire la mort.
ATTENTION
Ceci indique que le non respect de cet avertissement peut
entraîner des blessures légères ou modérées.
NOTICE : Ceci indique que la non-conformité à cet avis de
sécurité peut entraîner des dégâts à l'appareil ou à la propriété.
Note : Ceci vous avertit que d'importantes informations et/ou
conseils sont fournis.
Type d'installation
Pages
complètes
Gaz naturel avec ajustement pour hautes
altitudes
21 – 24
Gaz naturel avec conversion au G.P.L. 16 – 20
Gaz naturel avec conversion au G.P.L. et
ajustement pour hautes altitudes
16 – 24
Page. 14
Sécurité
INSTRUCTIONS IMPORTANTS DE SÉCURITÉ
LIRE TOUTES LES INSTRUCTIONS AVANT DE PROCÉDER
Lisez attentivement ce qui suit
Ce jeu ne peut pas servir à convertir d’anciens modèles de
surfaces de cuisson et de cuisinières PROFESSIONAL de
THERMADOR (voir la page couverture pour connaître les
modèles auxquels s'appliquent ces instructions). Ce jeu ne
peut pas être utilisé pour convertir les cuisinières pour
tout type de gaz PROFESSIONAL de THERMADOR, ou
tout autre type d’électroménager.
Conservez les pièces de gaz naturel pour une
reconversion potentielle de votre appareil à son
ajustement d'origine.
IMPORTANT : Seuls un technicien en entretien et en
réparation ou un installateur qualifié devraient procéder à
la conversion de cet appareil.
INSTALLATEUR : Veuillez laisser les instructions de
conversion de cet appareil au propriétaire.
PROPRIÉTAIRE : Veuillez conserver ces instructions pour
consultation ultérieure.
ATTENTION
Débranchez l’alimentation électrique et coupez
l’approvisionnement en gaz avant de procéder à la
conversion de cet appareil. Avant de mettre l’appareil
sous tension, assurez-vous que tous les boutons de
contrôle sont hors circuit.
AVERTISSEMENT
Ce jeu de conversion doit être installé par une
entreprise d’entretien et de réparation
qualifiée conformément aux instructions du
fabricant ainsi qu’aux codes et exigences en
vigueur. Si les directives comprises dans les
présentes instructions ne sont pas suivies avec
exactitude, un incendie, une explosion ou des
émanations de monoxyde de carbone
pourraient survenir, ce qui pourrait causer des
dommages matériels, entraîner des blessures
ou causer la mort. L’entreprise d’entretien et
de réparation qualifiée est responsable de
l’installation adéquate de ce jeu de conversion.
L’installation n’est pas considérée comme
adéquate et complète avant que le
fonctionnement de l’appareil converti n’ait é
vérifié en conformité avec les instructions
fournies par le fabricant du jeu de conversion.
Au technicien responsable de l’installation :
Il est important que vous preniez connaissance de ce qui
suit AVANT de procéder à la conversion de l’appareil.
Assurez-vous que le système d’approvisionnement en
gaz propane (LP) est disponible et prêt à être utilisé.
Cela s’avère particulièrement important pour les
nouvelles constructions.
Cuisinières mixtes converties au gaz propane (GPL) -
L'appareil doit d'abord être converti pour une
utilisation au gaz propane (GPL) avant d'être converti
pour une utilisation à haute altitude. Une trousse de
conversion au gaz propane est disponible au service à
la clientèle de Thermador. Il est impératif qu'un
professionnel accrédité procède à l'installation de la
trousse de conversion au gaz propane (GPL).
Page. 15
INSTRUCTIONS IMPORTANTS DE SÉCURITÉ
LIRE TOUTES LES INSTRUCTIONS AVANT DE PROCÉDER
Vous devez prévoir suffisamment de temps et de
ressources pour procéder convenablement et
totalement à la conversion au LP avant de quitter
l’endroit où vous avez effectué le travail. Chaque
étape décrite dans les présentes instructions doit être
suivie pour convertir en toute sécurité l’appareil et
assurer un fonctionnement adéquat au gaz propane.
LA CONVERSION INADÉQUATE OU INCOMPLÈTE
DE L’APPAREIL PEUT PRÉSENTER UN RISQUE
D’ACCIDENT.
Disposition de la Proposition 65 de l'État de la
Californie :
AVERTISSEMENT
Ce produit vous exposez à des produits chimiques,
comme du chlorure de vinyle, reconnus par l’État de la
Californie comme causant le cancer, des
malformations congénitales ou d’autres effets nocifs
sur la reproduction. Pour de plus amples
renseignements, consulter
www.P65Warnings.ca.gov.
AVERTISSEMENT
Si les orifices pour gaz naturel sont laissés en place
pendant que l’on tente de faire fonctionner l’appareil
avec le gaz propane, à un réglage de pression élevé
pour gaz LP, les brûleurs produiront une flamme plus
grosse ce qui peut émettre des niveaux élevés de
monoxyde de carbone dans la pièce, causer un
incendie ou une explosion.
AVERTISSEMENT
Ne laissez JAMAIS la conversion au gaz partiellement
terminée. Si l’appareil est utilisé alors que la
conversion n’est pas terminée, de hauts volumes de
monoxyde de carbone pourraient être relâchés, ou un
incendie ou une explosion pourrait survenir.
Pour les installations au Massachusetts :
1. L’installation doit être réalisée par un entrepreneur
qualifié ou agréé, un plombier ou un installateur de
gaz qualifié ou autorisé par l’État ou la région dans
laquelle cet appareil est installé.
2. Le robinet d’arrêt de gaz doit être pourvu d’une
poignée en « T ».
3. La longueur maximum autorisée du tuyau de gaz est
de 91,4 centimètres (36").
Page. 16
Instructions de Conversion au GPL
Avant de commencer
ATTENTION
AVANT DE PROCÉDER À LA CONVERSION, COUPEZ
L’APPROVISIONNEMENT EN GAZ DE L’APPAREIL,
PUIS DÉBRANCHEZ L’ALIMENTATION ÉLECTRIQUE.
ATTENTION
Lorsque vous branchez l’appareil au gaz propane,
assurez-vous que le réservoir de gaz propane est muni
de son propre mécanisme régulateur à haute pression.
La pression de gaz maximale de cet appareil ne
devrait pas excéder 14,0 pouces de colonne d’eau à
partir du régulateur du réservoir de gaz propane.
Pièces Fournies
Ciseaux
Clé Torx T-30 et T-32
Embouts hexagonaux de 16 et 9 mm
Tournevis à douille de 1/4 po
Douille ou clé de 7 mm ou de 9/32 po
Tournevis d’horloger avec lame de 1/8 po x 0,020 po
Le jeu de conversion au gaz comprend les articles
suivants
Préparation de conversion au
GPL
1. Coupez l’alimentation électrique du disjoncteur
principal ou de la boîte de fusible.
2. Couper une pièce d’adhésif mousse de 3/8 po de long
fournie dans le nécessaire et placer sur le bord du
tourne-écrou utilisé pour remplacer les orifices de
brûleur Star, comme montré.
Comment démonter la surface
de cuisson
IMPORTANT : Assurez-vous que la source d'alimentation
du disjoncteur est bloquée et que l'approvisionnement en
gaz est fermé.
1. Enlevez les grilles de la surface de cuisson et les
chapeaux des brûleurs STAR
mc
.
2. Utilisez l’embout hexagonal de 16 mm pour les
brûleurs identifiés par les lettres « D » ou « P ». Utilisez
l’embout hexagonal de 9 mm pour les brûleurs
identifiés par la lettre « B » pour retirer le venturi du
brûleur de chaque base.
CONSEIL : Si un embout hexagonal de 16 mm n'est
pas facilement accessible, sélectionnez un embout de
5/8 po. Autrement, il est possible d'utiliser un boulon
avec un embout de 5/8 po mis en double ou inséré sur
le mandrin d'une perceuse électrique.
Description
PALPKITHW5
(305 modèles
uniquement)
PALPKITHW
Ruban mousse, 1 po 1 1
Étiquette de conversion
au propane
1 1
Orifice de brûleur 073 2
Orifice de brûleur 090 1
Orifice de brûleur 099 1 3
Orifice de brûleur 113 1
Orifice de brûleur 115 3
La mousse aide à maintenir
l’orifice dans l’extrémité du
tourne-écrou pour ne pas qu’il
tombe dans l’appareil pendant
l’installation ou le retrait.
Page. 17
3. Débranchez l'allumeur. Soulevez doucement la base
du brûleur.
4. Enlevez doucement la plaque du brûleur.
5. Pour faciliter le retrait des plateaux collecteurs
enlevez vis Torx T-20 en acier inoxydable de la
garniture avant pour installation de type îlot.
6. Enlevez le plateau collecteur en les faisant tourner
vers le haut puis en le poussant vers l'arrière.
7. Enlevez l'écran thermique, s'il y en a un. Certains
modèles sont munis d'un écran à largeur double qui
se prolonge sous le plateau collecteur adjacent.
Conversion d’un régulateur
Le régulateur de pression du gaz est situé près du coin
arrière gauche, à l’intérieur de la partie supérieure de
l’appareil. L'emplacement exact varie selon le modèle.
3. Réinstallez la pièce de conversion configurée pour le
gaz propane – sur le dessus du régulateur.
1) Base du brûleur 2) Electrode
3) Boîtier de l’allumeur 4) Fil de l’allumeur
1
2
3
4
1. Enlevez la pièce
de conversion
avec une clé fixe
ou une douille de
7/8 po.
2. Lisez les lettres apparaissant sur la tige. Les lettres
"NAT" sont écrites au bas de la tige. Retirez le
piston de la partie inférieure du bouchon de
conversion. Faites ressortir la tige de la base de la
pièce, inversez la tige de manière à ce que
l’extrémité LP soit visible et remettez la tige dans la
pièce.
1) Chapeau en laiton 2) Rondelle de fermeture
3) Piston 4) Corps du détendeur
LP
NAT
1
2
3
4
Page. 18
Retrait des orifices des
brûleurs
1. Utilisez une douille de 7 mm (ou 9/32 po) avec une clé
de1/4 po et une rallonge pour atteindre l’orifice à gaz
naturel à travers le venturi et l’enlever du porte-
injecteur du brûleur
.
Remplacement des orifices des
brûleurs
1. Trouvez l'orifice du brûleur de
surface de G.P.L. adéquat dans la
trousse. Le diamètre de l'orifice
est inscrit sur le côté de chaque
pièce.
2. Installez les orifices à leur emplacement adéquat,
conformément aux tableaux.
Les orifices de remplacement du jeu de
conversion au LP ont un filetage cylindrique (et
non un filetage au pas de gaz) et ne requièrent
pas l’utilisation de mastic pour joints filetés.
Modèle 304
Classification de BTU Taille de l'orifice
(1) Naturel 15000, GPL 12000 BTU 105
(2) Naturel 18000, GPL 15000 BTU 115
(3) Naturel 15000, GPL 12000 BTU 105
(4) Naturel 18000, GPL 15000 BTU 115
44
11
22
33
Modèle 305
Classification de BTU Taille de l'orifice
(1) Naturel 8000, GPL 6000 BTU 073
(2) Naturel 18000, GPL 15000 BTU 115
(3) Naturel 10000, GPL 9100 BTU 90
(4) Naturel 8000, GPL 6000 BTU 073
(5) Naturel 15000, GPL 12000 BTU 105
Modèle 364 avec plaque chauffante
Classification de BTU Taille de l'orifice
(1) Naturel 15000, GPL 12000 BTU 105
(2) Naturel 18000, GPL 15000 BTU 115
(3) Non applicable
(4) Naturel 15000, GPL 12000 BTU 105
(5) Naturel 18000, GPL 15000 BTU 115
33
55
11
22
44
33
55
11
22
44
Page. 19
3. Procédez à une brève inspection des fuites de gaz sur
chaque orifice et raccord selon les instructions
données à la section « Inspection des fuites de gaz ».
L’inspection des fuites devrait se faire une fois que la
conversion des orifices est terminée et avant que les
brûleurs ne soient réassemblés et testés.
Modèle 366
Classification de BTU Taille de l'orifice
(1) Naturel 15000, GPL 12000 BTU 105
(2) Naturel 18000, GPL 15000 BTU 115
(3) Naturel 15000, GPL 12000 BTU 105
(4) Naturel 18000, GPL 15000 BTU 115
(5) Naturel 15000, GPL 12000 BTU 105
(6) Naturel 18000, GPL 15000 BTU 115
Modèle 364 avec Gril
Classification de BTU Taille de l'orifice
(1) Naturel 15000, GPL 12000 BTU 105
(2) Naturel 18000, GPL 15000 BTU 115
(3) Non applicable
(4) Naturel 15000, GPL 12000 BTU 105
(5) Naturel 18000, GPL 15000 BTU 115
33
44
66
11
22
55
33
55
11
22
44
Modèle 486 avec gril
Classification de BTU Taille de l'orifice
(1) Naturel 15000, GPL 12000 BTU 105
(2) Naturel 18000, GPL 15000 BTU 115
(3) Naturel 15000, GPL 12000 BTU 105
(4) Naturel 18000, GPL 15000 BTU 115
(5) Non applicable
(6) Naturel 15000, GPL 12000 BTU 105
(7) Naturel 18000, GPL 15000 BTU 115
Modèle 486 avec plaque chauffante
Classification de BTU
Taille de
l'orifice
(1) Naturel 15000, GPL 12000 BTU 105
(2) Naturel 18000, GPL 15000 BTU 115
(3) Naturel 15000, GPL 12000 BTU 105
(4) Naturel 18000, GPL 15000 BTU 115
(5) Non applicable
(6) Naturel 15000, GPL 12000 BTU 105
(7) Naturel 18000, GPL 15000 BTU 115
33
44
77
11
22
66
55
33
44
77
11
22
66
55
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38

Thermador PALPKITHW5 Guide d'installation

Catégorie
Cuisinières
Taper
Guide d'installation