4
The refrigerants used for air conditioners are environmentally friendly hydrocarbons R32. This kind of erant is
combustible and odorless. Moreover, it can burn and explode under certain condition. However, there will be no
risk of burning and explosion if you comply with the following table to install your air conditioner in a room with an
appropriate area and use it correctly.
Compared with ordinary refrigerants, Refrigerant R32 is environmentally friendly and do not destroy the ozone
sphere and that its value of greenhouse effect is also very low.
Room area requests for air conditioner with Refrigerant R32
Refrigerant Capacity(Btu)
9K
Room Area
R32
Warnings
Please read the manual before installation, using, maintenance.
Do not use means to accelerate the defrosting process or to clean, other than those recommended by the
manufacturer.
Do not pierce or burn the appliance.
The appliance shall be stored in a room without continuously operating sources (for example: open flames,
an operating ignition gas appliance or an operating electric heater.)
Please contact the nearest after-sale service center when maintenance is necessary. At the time of
maintenance, the maintenance personnel must strictly comply with the Operation Manual provided by the
corresponding manufacturer and any non-professional is prohibited to maintain the air conditioner.
It is necessary to comply with the provisions of gas-related national laws and regulations.
It is necessary to clear away the refrigerant in the system when maintaining or scrapping an air conditioner.
Be aware that refrigerants may not contain an odour.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or supervision or instruction concerning use of the appliance by a person responsible for
their safety.Children should be supervised to ensure that they do not play with the appliance.
Unit operation limits: Outdoor side 61~110 , 80%RH; indoor side 61~90 , 80%RH.
Introduction to Refrigerants R32
12K
18K
24K
Above 4m2
Above 4m2
Above 15m2
Above 25m2
14.5
23 to 34
584mm to 863mm
368
34 863
368
14.5
Important Considerations
Before installing the appliance, you must read the manual carefully to get the safety
information and notes.
A leak test must be done after the installation is completed.
It is a must to do the safety inspection before maintaining or repairing an air
conditioner using combustible refrigerant in order to ensure that the fire risk is
reduced to minimum.
It is necessary to operate the machine under a controlled procedure in order to
ensure that any risk arising from the combustible gas or vapor during the operation
is reduced to minimum.
Unit refrigerant charge amount: refer to unit name plate marking.
Introduction to Refrigerants R32(Only for R32 Model)
1. Site Safety
2. Operation Safety
Open Flames ProhibitedVentilation Necessary
Open Flames Prohibited
Mind Static Electricity Must Wear Protective Clothing and anti-static gloves Don't use mobile phone
3. Installation Safety
Refrigerant Leak Detector
Appropriate Installation Location
The left picture is the schematic diagram of a refrigerant leak detector.
Please note that:
1. The installation site should be in a well-ventilated condition.
2. The sites for installing and maintaining an air conditioner using Refrigerant R32 should be free from open fire
or welding, smoking, drying oven or any other heat source higher than 548 which easily produces open fire.
3. When installing an air conditioner, it is necessary to take appropriate anti-static measures such as wear
anti-static clothing and/or gloves.
4. It is necessary to choose the site convenient for installation or maintenance wherein the air inlets and outlets of
the indoor and outdoor units should be not surrounded by obstacles or close to any heat source or combustible
and/or explosive environment.
5. If the indoor unit suffers refrigerant leak during the installation, all the personnel should go out till the refrigerant
leaks completely for 15 minutes. If the product is damaged, it is a must to carry such damaged product back to
the maintenance station and it is prohibited to weld the refrigerant pipe or conduct other operations on the user's
site.
6. It is necessary to choose the place where the inlet and outlet air of the indoor unit is even.
7. It is necessary to avoid the places where there are other electrical products, power switch plugs and sockets,
kitchen cabinet, bed, sofa and other valuables right under the lines on two sides of the indoor unit, and also
prevent mechanical damage from occurring.
9
0
11
For maximum cooling set the MODE dial to “ . In HIGH COOL mode, the fan will
automatically go to high. This will help circulate the cool air throughout the room.
The fan will operate on low in mode.
To direct the airflow, use the horizontal
wheel to control the horizontal direction,
air deflector to control the vertical
direction.
Turn on the unit by rotating the MODE dial to the desired setting.
For fan only modes, choose either or . The air conditioner will not cool
the room when in fan mode.
Turn the TEMP dial to set the desired room temperature. For maximum cooling
turn the TEMP dial to 7 (Max Cool).
The controls featured in this manal are representative of many availabie models.
Your model may offer sightly different features.
air deflector air deflectorhorizontal wheel
CAUTION
Air Filter Cleaning
Air Filter Cleaning
Cabinet
The air filter should be checked at least once a month to
see if cleaning is necessary. Trapped particles in the
filter can build up and cause an ac cumulationof frost on
the cooling coils.
Clean your air conditioner occasionally to keep it looking
new. Be sure to unplug the unit before cleaning to
prevent chock or fire hazards.
Remove the filter by sliding out from the right-hand side.
Wash the filter using liquid dishwashing detergent and
warm water. Rinse filter thoroughly. Gently shake excess
water from the filter. Be sure the filer is thoroughly dry
before replacing. Or, instead of washing you may vacuum
the filter clean.
Never use hot water over 40 (140 ) to clean the air filter.
Never attempt to operate the unit without the air filter.
Be sure to unplug the air conditioner to prevent shock or fire
hazard. The cabinet and front may be dusted with an oil-free
cloth or washed with a cloth dampened in a solution of warm
water and mild liquid dishwashing detergent. Rinse
thoroughly and wipe dry.
Never use harsh cleaners, wax or polish on the cadinet front.
Be sure to wring excess water from the cloth before wiping
around the controls. Excress water in or around the controls
may cause damage to the air conditoner.
Plug in air conditioner.
lf you plan to store the air conditioner during the winter,
remove it carefully from the window according to the
installation instructions. Cover it with plastic or return it to
the original carton.
AIR CONDITIONER FEATURES
POWER
COOLING MODE
FAN MODE
THERMOSTAT
DIRECTIONAL LOUVERS
NOTE
Winter Storage
12
RACM5022-6COM
406x332x305
4.5
6.1
360/915(2.5/6.3MPa)
21
460
600
15.98x13.07x12.0
460x375x385
18.11x14.76x15.16
16.0/19.0
35.3/41.9
3
4
15
ATTACH YOUR PROOF OF PURCHASE HERE, PROOF OF PURCHASE IS REQUIRED
TO OBTAIN WARRANTY SERVICE.
Please have the following information available when you contact the Support Team:
• Name, address and telephone number.
• Model number and serial number.
• A clear, detailed description of the problem.
• Proof of purchase including dealer or retailer name, address and date of purchase.
To make a warranty claim, please email [email protected] or call 1-800-968-9853.
For service assistance and product information, please call: 1-800-968-9853.
Curtis International Ltd.
7045 BECKETT DRIVE, UNIT 15, MISSISSAUGA, ON, L5S 2A3 www.curtisint.com
RACM5022-6COM
4
95
1110
10
11
12
15
13 14
Carte de garantie
Ce produit a été fabriqué et vendu sous la responsabilité de Curtis International Ltd.
RCA, le logo RCA, le logo des deux chiens (Nipper et Chipper), sont des marques déposées ou des
marques commerciales de Technicolor (S.A.) ou de ses affiliés et sont utilisés sous licence par
Curtis International Ltd.
Tout autre produit, service, société, nom commercial ou produit et logo référencés ici ne sont ni
approuvés ni sponsorisés par Technicolor (S.A.) ou ses affiliés.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37

RCA RACM5022-6COM Manuel utilisateur

Catégorie
Climatiseurs split-system
Taper
Manuel utilisateur

dans d''autres langues