For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent
property damage, personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in
....the vidnity °f th!s °! any °ther app!!ance:......................................................................................................................................................................................................................................................................................................................
AWARNING - RISK OF FIRE
Read all of the following instructions before installing and using this appliance:
* Destroy the carton and plastic bags after the dryer is unpacked. Children might use them for play. Cartons covered
with rugs, bedspreads, or plastic sheets can become airtight chambers causing suffocation. Place all materials in a
garbage container or make materials inaccessible to children.
* Clothes dryer installation and service must be performed by a qualified installer, service agency or the gas supplier.
* Install the clothes dryer according to the manufacturer's instructions and local codes.
* The electrical service to the dryer must conform with local codes and ordinances and the latest edition of the
National Electrical Code, ANS[/NFPA 70, or in Canada, the Canadian electrical code C22.I part 1.
* The gas service to the dryer must conform with local codes and ordinances and the latest edition of the National
Fuel Gas Code ANSI Z223.1, or in Canada, CAN/ACG BI49.1-2000. An individual manual shut-off valve must be
installed within 6 ft (i.83 m) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1/NFPA 54.
* The dryer is designed under ANSI Z 21.5.1 or ANS[/UL 2158 - CAN/CSA C22.2 No. i12 (latest editions) for HONE
USE only. This dryer is not recommended for commercial applications such as restaurants, beauty salons, etc.
* Do not install a clothes dryer with flexible plastic or flexible foil venting material. Flexible venting materials are
known to collapse, be easily crushed and trap lint. These conditions will obstruct clothes dryer airflow and increase
the risk of fire.
* The instructions in this manual and all other literature included with this dryer are not meant to cover every
possible condition and situation that may occur. Good safe practice and caution NUST be applied when installing,
operating and maintaining any appliance.
WHAT TO DO IF YOU SMELL GAS:
* Do not try to light any appliance.
* Do not touch any electrical switch; do not use any
phone in your building.
* Clear the room, building or area of all occupants.
* Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
* If you cannot reach your gas supplier, call the fire
department.
personmoveor !!Ittheapp!iance: ..................
Save these instructions
for future reference.
Pre-Installation Requirements
Tools and materials needed for installation:
* Adjustable pliers * Carpenter's level
* Phillips, straight, & square bit * External vent hood
screwdrivers * 4-inch (!02 mm), rigid metal or
* Adjustable wrench semi-rigid metal exhaust duct work
* Pipewrench for gas supply (gas * 3-wire or 4-wire 240 volt cord kit
dryer) (electric dryer)
* @-resistant thread tape (for natural * 4 in. (!02 mm) clamp
gas or LPsupply, gas dryer)
* Gas line shutoff valve (gas dryer)
* _/2NPTunion flare adapters (x2)
and flexible gas supply line (gas
dryer)
Netal foil tape (not duct tape)
Pleasereadallinstructionsbeforeusingthisdryer.
Recognize safety syrnboisr words
and labels
Safety items throughout this manual are labeled with
a WARNING or CAUTION based on the risk type as
described below:
Definitions
This is the safety alert symbol. It is used to alert
you to potential personal injury hazards. Obey all safety
messages that follow this symbol to avoid possible injury
or death.
DANGER indicates an imminently hazardous situation
Exhaust Venting
Free-flowing, clear of lint buildup
4 inch (102 mm) rigid or semi-rigid ducting of
minimal length and turns
E_ NOfoil or plastic venting material
E_ Approved vent hood exhausted to outdoors
Leveling
E_ Dryer is level, side-to-side and front-to-back
E3 Cabinet is setting solid on all corners
GasSupplyCGasDryer:
E_ Manual shutoff valve present in supply
E_ AIt connections sealed with approved sealer and
wrench tight
E_ Conversion kit for LPsystem
E_ Gas supply turned on
E3 No leaks present at all connections -
check with soapy water, NEVERcheck with flame
which if not avoided will result in death or serious
injury, 240v Electric Supply (Electric Dryer)
E3 Approved NEMA 10-30R or 14-30R service cord
with all screws tight on terminal block
E3 Approved strain relief installed
E3 Terminal access cover installed before initial
operation
Door Reversal
E3 Follow detailed instructions in this guide
CAUTION indicates a potentially hazardous situation E3 Test hinge and latch for function
which, if not avoided, may result in minor or moderate
injury. Electrical Power
E3 House power turned on
IMPORTANT indicates installation, operation or
maintenance information which is important but not
hazard-related.
E3 Dryer plugged in
Final Checks
Installation Instructions and Use and Care
Guide read thoroughly
Door latches and drum tumbles when cycle
starts
Registration card sent in
Becauseofpotentiallyinconsistentvoltagecapabilities,theuseofthisdryerwithpowercreatedbygaspowered
generators,solarpoweredgenerators,windpoweredgeneratorsoranyothergeneratorotherthanthelocalutility
companyisnotrecommended,
Electrical requirements for electric dryer
CIRCUIT - Individual 30 amp. branch circuit fused with 30 amp. time delay fuses or circuit breakers. Use separately
fused circuits for washer and dryer. DO NOT operate a washer and a dryer on the same circuit.
POWER SUPPLY- 3-wire or 4-wire, 240 volt, single phase, 60 Hz, Alternating Current.
through the neutral.
OUTLET RECEPTACLE- NEMA 10-3ORor NEMA 14-30R rece )tacie to be located so the power supply cord is accessible
when the dryer is in the installed position.
GROUNDING CONNECTION - See "Grounding requirements" in Electrical Installation section.
3-WIRE POWERSUPPLYCORD KIT (not supplied)
3-wire receptacle
(NEMA type 10-30R)
The dryer MUSTemploy a 3-conductor power
supply cord NEMA 10-30 type SRDTrated at 240
volt AC minimum, 30 amp, with 3 open end spade
lug connectors with upturned ends or closed
loop connectors and marked for use with clothes
dryers. For 3-wire cord connection instructions see
ELECTRICALCONNECTIONS FOR A 3-WIRE SYSTEM.
4-WIRE POWER SUPPLYCORD KIT (not supplied)
4-wire receptacle
(NEMA type 14-30R)
The dryer MUST employ a 4-conductor power supply
cord NEMA 14-30 type SRDTor ST (as required) rated
at 240 volt AC minimum, 30 amp, with 4 open end
spade lug connectors with upturned ends or closed
loop connectors and marked for use with clothes
dryers. For 4-wire cord connection instructions see
ELECTRICALCONNECTIONS FORA 4-WIRE SYSTEM.
Electrical requirements for gas dryer
CIRCUIT - Individual, properly polarized and grounded
15 amp. branch circuit fused with 15 amp. time delay
fuse or circuit breaker.
POWER SUPPLY- 2-wire, with ground, !20 volt, single
phase, 60 Hz, Alternating Current.
POWER SUPPLYCORD - The dryer is equipped with a 120
volt 3-wire power cord.
GROUNDING CONNECTION - See "Grounding
requirements" in Electrical Installation section.
Groundingtype
wal receptacle
_- Do not,under -"
/ _.\ I |anycircurnstances
\ I_ grounding prong.
h
B-pronggroundedpl
Gas supply requirements
; EXPLOSION HAZARD
Uncoated copper tubing will corrode when subjected
to natural gas, causing gas leaks. Use ONLYblack iron,
stainless steel, or plastic-coated brass piping for gas
supply.
1 Installation MUST conform with local codes, or in
the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.I (latest edition).
2 The gas supply line should be 1/2 inch (1.27 cm)
pipe.
3 If codes allow, flexible metal tubing may be used
to connect your dryer to the gas supply line. The
tubing MUSTbe constructed of stainless steel or
plastic-coated brass.
4. The gas supply line MUSThave an individual
shutoff valve installed in accordance with the
B!49.!, Natural Gasand Propane Installation Code.
5 A !/8 inch (0.32 cm) N.P.T.plugged tapping,
accessible for test gauge connection, MUST be
installed immediately upstream of the gas supply
connection to the dryer.
6 The dryer MUSTbe disconnected from the gas
supply piping system during any pressure testing
of the gas supply piping system at test pressures in
excess of !/2 psig (3.45 kPa).
7 The dryer MUSTbe isolated from the gas supply
piping system during any pressure testing of the
gas supply piping system at test pressures equal to
or tessthan Z/2 psig (3.45 kPa).
8 Connections for the gas supply must comply with
the Standard for Connectors for GasAppliances,
ANSI Z21.24.
Exhaust system requirements
Use only 4 inch (i02 mm) diameter (minimum) rigid
or flexible metal duct and approved vent hood which
has a swing-out damper(s) that open when the dryer
is in operation. When the dryer stops, the dampers
automatically close to prevent drafts and the entrance
of insects and rodents. To avoid restricting the outlet,
maintain a minimum of !2 inches (30.5 cm) clearance
between the vent hood and the ground or any other
obstruction.
FIRE HAZARD
Failure to follow these instructions can create excessive
drying times and fire hazards.
The following are specific requirements for proper
and safe operation of your dryer,
FIRE HAZARD
Do not install a clothes dryer with flexible plastic or
metal foil venting materials. Flexible venting materials
are known to collapse, be easily crushed and trap tint.
These conditions witt obstruct clothes dryer airflow and
increase the risk of fire.
If your present system is made up of plastic duct or
metal foil duct, replace it with a rigid or semi-rigid metal
duct. Also, ensure the present duct is free of any lint prior
to installing dryer duct.
li;;:_:_;:;_!!:_iiiii; ;_i¸__;i;_¸i¸!_;;_i_ii ;_11 iiii
Correct
[_; ¸i¸i¸i¸i¸i¸i¸i¸i¸i¸i¸i¸i¸i¸i¸i¸i
Incorrect
L
Exhaust system requirements, continued
FIRE HAZARD FIRE HAZARD
A clothes dryer must be exhausted outdoors• Do not Exceeding the length of duct pipe or number of elbows
exhaust dryer into a chimney, a wall, a ceiling, an attic, allowed in the "MAXIMUM LENGTH" charts can cause
a crawl space or any concealed space of a building• A an accumulation of lint in the exhaust system• Plugging
clothes dryer produces combustible lint. If the dryer is
not exhausted outdoors, some fine lint will be expelled
into the laundry area• An accumulation of tint in any
area of the home can create a health and fire hazard.
The dryer must be connected to an exhaust outdoors.
Regularly inspect the outdoor exhaust opening and
remove any accumulation of lint around the outdoor
exhaust opening and in the surrounding area.
FIRE HAZARD
Do not allow combustible materials (for example:
clothing, draperies/curtains, paper) to come in
contact with exhaust system. The dryer MUST NOT
be exhausted into a chimney, a wall, a ceiling,
or any concealed space of a building which can
accumulate lint, resulting in a fire hazard.
Do not screen the exhaust ends of the vent system,
or use any screws, rivets or other fasteners that
extend into the duct to assemble the exhaust
system. Lint can become caught in the screen, on
the system could create a fire hazard, as welt as
increase drying times.
MAXIMUM LENGTH
of 4" (102mm) Rigid Metal Duct
9 VENT HOOD TYPE
(Preferred)
4" 2.5"
(102ram) Iouvered (6.35cm)
0 64 ft. (19.5 m) 48 ft. (14.6 m)
1 52 ft. (15,9 m) 40 ft, (12.2 m)
2 44 ft. (13,5 m) 32 ft, (9.8 m)
3 36 ft. (11 m) 24 ft. (7.3 m)
4 28 ft. (9,5 m) 16 ft, (4.9 m)
o Do not install flexible plastic or flexible foil venting
the screws or rivets, clogging the duct work and material.
creating a fire hazard as welt as increasing drying
..... * If nsta ngsem-rgdventng do not exceed8ft
t mes Use an approved vent hood to term nate the "2 4 m" duct len th
_. ) g
duct outdoors, and seal all ]omts wtth metal fotl duct .....
tape, All male duct pipe fittings MUST be instalied
downstream with the flow of air.
Exhaust system requirements, continued
Install male fittings in correct direction:
CORRECT INCORRECT
In installations where the exhaust system is not described
in the charts, the following method must be used to
determine if the exhaust system is acceptable:
:1. Connect an inclined or digital manometer between
the dryer and the point the exhaust connects to the
dryer.
2 Set the dryer timer and temperature to Air Dry and
start the dryer.
3 Read the measurement on the manometer.
4 The system back pressure MUST NOT be higher
than 0.75 inches of water column. If the
system back pressure is tess than 0.75 inches of
water column, the system is acceptable. If the
manometer reading is higher than 0.75 inches of
water column, the system is too restrictive and the
installation is unacceptable.
Although vertical orientation of the exhaust system is
acceptable, certain extenuating circumstances could
affect the performance of the dryer:
Only rigid metal duct work should be used.
Venting vertically through a roof may expose the
exhaust system to down drafts causing an increase
in vent restriction.
Running the exhaust system through an
uninsulated area may cause condensation and
faster accumulation of lint.
Compression or crimping of the exhaust system will
cause an increase in vent restriction.
The exhaust system should be inspected and
cleaned a minimum of every 18 months with
normal usage. The more the dryer is used, the
more often you should check the exhaust system
and vent hood for proper operation.
Exhaust direction
Directional exhausting can be accomplished by installing
a quick-turn 90 ° dryer vent elbow directly to exhaust
outlet of dryer. Dryer vent elbows are available through
your local parts distributor or hardware store.
See also Clearance Requirements on the next page.
Use of 90 ° quick-turn
elbow is required to meet
minimum installation
depth of free-standing
dryer.
Manufactured or mobile home installation
1 Installation MUST conform to current Manufactured
Home Construction & Safety Standard, Title 24
CFR, Part 32-80 (formerly the Federal Standard
for Mobile Home Construction and Safety, Title 24,
HUD Part 280) or Standard CAN/CSAZ240 MH.
2 Dryer MUST be exhausted outside (outdoors, not
beneath the mobile home) using metal ducting
that wilt not support combustion. Metal ducting
must be 4 inches (i0.i6 cm) in diameter with no
obstructions. Rigid metal duct is preferred.
3 If dryer is exhausted through the floor and area
beneath the mobile home is enclosed, the exhaust
system MUST terminate outside the enclosure with
the termination securely fastened to the mobile
home structure.
4 Refer to previous sections in this guide for other
important exhaust venting system requirements.
5 When installing a gas dryer into a mobile home, a
provision must be made for outside make up air.
This provision is to be not less than twice the area
of the dryer exhaust outlet.
6 Installer MUST anchor this dryer to the floor
with approved Mobile Home Installation Kit - P/N
137087200.
Installation in a Recess or Closet
1 A dryer installed in a bedroom, bathroom, recess or
closet, MUST be exhausted outdoors.
2 No other fuel burning appliance shall be installed in
the same closet as the gas dryer.
3 Your dryer needs the space around it for proper
ventilation.
DO NOT install your dryer in a closet with a solid door.
4 Closet door ventilation required: A minimum
of !20 square inches (774.2 cm 2) of opening,
equally divided at the top and bottom of the
door, is required. Openings should be located 3
inches (7.6 cm) from bottom and top of door.
Openings are required to be unobstructed when a
door is installed. A Iouvered door with equivalent
air openings for the full length of the door is
acceptable,
closet door
Clearance requirements
INSTALLYOUR DRYER:
I In anareaexposedtodrippingwateroroutside
weatherconditions.
2 In anareawhere itwillcome incontactwith
curtains,drapes,oranythingthatwillobstruct
theflowofcombustionand ventilationair.
3 On carpet.FloorMUST be solidwitha maximum
slope of i inch (2.54 cm).
EXPLOSION HAZARD
Do not install the dryer where gasoline or other
flammables are kept or stored. If the dryer is installed
in a garage, it must be a minimum of !8 inches (45.7
cm) above the floor. Failure to do so can result in
death, explosion, fire or burns.
MINIMUM INSTALLATION CLEARANCES - Inches (cm)
SIDES REAR TOP FRONT
Alcove 0" (0 cm) 0" (O cm)* 23" (58.5 cm) n/a
Closet 0"(0 crn) 0" (0 cm) _ 23" (58.5 crn) 1" (2.5 crn)
* Dryer must be vented straight back to achieve
0" (0 cm) rear installation.
(oO#i_) o"
(0cm)
1" "
(2.5 cm) (00cm)
_ii_ -iL
To achieve an installation with 0" (0 cm) clearance
for the back of the dryer (for other than straight back
venting), a quick-turn 90 ° dryer vent elbow must be
installed as described previously in this manual,
Dryer Dimensions
I_ 27' (68,5 cm)
38,5"
(98 cm)
42,5"
(108 cm)
electrical
supply on
rear of unitI
gas supply _
pipe on rear
of gas unit
(34,5 cm)
to center of rear vent
:enterline height
3.7"
(9,5 cm) floorline
S0" (127cm) _lJ
to
I_ 29" (73,5 cm)
to front of dosed door
iPowe, sul)ply cmd length on gas unit ap]3mxima_ely 6O in( he£ (1525 cm)
i!!i!i!l!_!0 ill
Electrical installation
The following are specific requirements for proper and
safe electrical installation of your dryer. Failure to follow
these instructions can create electrical shock and/or a
fire hazard.
ELECTRICAL SHOCK HAZARD
This appliance MUST be properly grounded.
Electrical shock can result if the dryer is not properly
grounded. Follow the instructions in this manual for
proper grounding.
o
Do not use an extension cord with this dryer. Some
extension cords are not designed to withstand the
amounts of electrical current this dryer utilizes
and can melt, creating electrical shock and/
or fire hazard. Locate the dryer within reach of
the receptacle for the length power cord to be
purchased, allowing some slack in the cord. Refer to
the pre-installation requirements inthis manual for
the proper power cord to be purchased power supply.
ELECTRICAL SHOCK HAZARD
A U.L.-approved strain relief must be installed onto
power cord. If the strain relief is not attached, the
cord can be pulled out of the dryer and can be cut
by any movement of the cord, resulting in electrical
shock.
Do not use an aluminum wired receptacle with a
copper wired power cord and plug (or vice versa).
A chemical reaction occurs between copper and
aluminum and can cause electrical shorts. The
proper wiring and receptacle is a copper wired
power cord with a copper wired receptacle.
Grounding requirements - Electric dryer (USA)
conductor can result in a risk of electrical shock. Check
with a licensed electrician if you are in doubt as to
whether the appliance is properly grounded.
For a grounded, cord-connected dryer:
1 The dryer MUSTbe grounded. In the event of a
malfunction or breakdown, grounding will reduce
the risk of electrical shock by a path of least
resistance for electrical current.
2 After you purchase and install a 3 wire or 4 wire
power supply cord having an equipment-grounding
conductor and a grounding plug that matches you
wiring system, the plug MUSTbe plugged into
an appropriate, copper wired receptacle that is
properly installed and grounded in accordance with
all local codes and ordinances. If in doubt, call a
licensed electrician.
3 DO NOT modify the plug you've installed on this
appliance. If it will not fit the outlet, have a proper
outlet installed by a qualified electrician.
For a permanently connected dryer:
1 The dryer MUST be connected to a grounded
metal, permanent wiring system; or an equipment
grounding conductor must be run with the circuit
conductors and connected to the equipment-
grounding terminal or lead on the appliance.
Grounding requirements - Electric dryer (Canada)
ELECTRICAL SHOCK HAZARD
Improper connection of the equipment grounding
conductor can result in a risk of electrical shock. Check
with a licensed electrician if you are in doubt as to
whether the appliance is properly grounded.
For a grounded, cord-connected dryer:
1 The dryer MUST be grounded. In the event of a
malfunction or breakdown, grounding will reduce the
risk of electrical shock by a path of least resistance
for electrical current.
2 Since your dryer is equipped with a power supply
cord having an equipment-grounding conductor and
a grounding plug, the plug must be plugged into
an appropriate outlet that is properly installed and
grounded in accordance with all local codes and
ordinances. If in doubt, call a licensed electrician.
3 DO NOT modify the plug provided with this
appliance. If it will not fit the outlet, have a proper
outlet installed by a qualified electrician.
Grounding requirements = Gas dryer (USA and Canada)
1 The dryer is equipped with a three-prong
(grounding) plug for your protection against shock
hazard and should be plugged directly into a
properly grounded three-prong receptacle.
2 The plug must be plugged into an appropriate
outlet that is properly installed and grounded in
accordance with all local codes and ordinances. If
in doubt, call a licensed electrician.
3 DO NOT modify the plug provided with this
appliance. If it will not fit the outlet, have a proper
outlet installed by a qualified electrician.
Grounding type
wail receptacle
f Do not. under
any circumstances
or bypass the
__ grounding prong.
Pc_er cord with
3-prong grounded plug
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii_i_i_i_i!!!_i_iiii_!i! _ii _i!_i!i_!i!_iii_i_ii_i_illi_i_ii!i_ii_i_iii!_ii
Gas connection
:1. Remove the shipping cap from gas pipe at the rear
of the dryer.
DO NOT connect the dryer to L.P,gas service without
converting the gas valve. An L.P.conversion kit must
be installed by a qualified gas technician.
Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or
approved pipe from gas supply line to the 3/8 inch
(0.96 cm) pipe located on the back of the dryer.
Use a 1/2 inch to 3/8 inch (1.27 cm to 0.96 cm)
reducer for the connection. Apply an approved
thread sealer that is resistant to the corrosive
action of liquefied gases on all pipe connections.
Manua GAS FLOW
Shutoff Flare _ Flare |
Valve Union Union |
l
,o_/:_ed71_Fi_'_i l_'_:::l_:_\_/_'i I I
: ,_tl t ' t t [
\. Nipple Flexible Inlet Pipe on |
Open Connector Back of Dryer |
All connectionsmustbe wrench-tightened J
3 Open the shutoff valve in the gas supply line to
allow gas to flow through the pipe. Wait a few
minutes for gas to move through the gas line.
Open position
4 Check for gas system leaks with a manometer. If a
manometer is not available, test all connections by
brushing on a soapy water solution,
The supply line must be equipped with an approved
manual shutoff valve. This valve should be located in
the same room as the dryer and should be in a location
that allows ease of opening and closing. Do not block
access to the gas shutoff valve.
Electrical connection (non=Canada) - 3 wire cord
3-wire receptacle
(NEMA type 10-30R)
ELECTR:CALS.OCK.AzARD
Failure to disconnect power source before servicing
could result in personal injury or even death.
:1. Turn off power supply to outlet.
2 Remove the screw securing the terminal block
access cover in the lower corner on the back of the
dryer.
3 Install a UL-approved strain relief according to the
power cord/strain relief manufacturer's instructions
in the power cord entry hole below the access
panel. At this time, the strain relief should be
loosely in place.
4 Thread an UNPLUGGED,UL-approved, 30 amp.
power cord, NEHA 10-30 type SRDT,through the
strain relief.
5 Attach the power cord neutral (center wire)
conductor to the SILVERcolored center terminal on
the terminal block, Tighten the screw securely.
6 Attach the remaining two power cord outer
conductors to the outer, BRASScolored terminals
on the terminal block, Tighten both screws
securely,
(SILVER terminal)
Line 1
(BRASS terminal)
_ Internal ground
(GREEN screw)
recoveryslot
If a terminal screw falls during cord installation, it can
Do not make a sharp bend or crimp wiring/conductor
at connections.
7 Follow manufacturer's guidelines for firmly securing
the strain relief and power cord.
8 Reinstall the terminal block cover.
DO NOT remove
Neutral
internal ground in terminal
a 3-wire system]!
:If moving dryer from a 4-wire system and installing it
in a 3-wire system, move the internal ground from the
center terminal back to the GREENscrew next to the
terminal block.
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii_i_i_i_i!!!_i_iiii_!i! _ii _i!_i!i_!i!_iii_i_ii_i_illi_i_ii!i_ii_i_iii!_ii
Electrical connection (non=Canada) = 4 wire cord
4-wire receptacle
(NEMA type 14-30R)
3. Turn off power supply to outlet.
2 Remove the screw securing the terminal block
access cover in the lower corner on the back of the
dryer.
3 Install a UL-approved strain retief according to the
power cord/strain relief manufacturer's instructions
in the power cord entry hole below the access
paneh At this time, the strain relief should be
loosely in place.
4 Thread an UNPLUGGED,UL-approved, 30 amp.
power cord, NEHA 14-30 type ST or SRDT,through
the strain relief.
5 Disconnect the internal (WHITE) dryer harness
ground wire from the (GREEN) ground screw next
to the terminal block.
6 Attach the ground (GREEN) power cord wire to the
cabinet with the ground (GREEN) screw. Tighten
the screw securely.
7 Nave the internal dryer harness ground (WHITE)
wire to the terminal block and attach it along with
the neutral (WHITE) power cord wire conductor
to the center, SILVERcolored terminal on the
terminal block. Tighten the screw securely.
8 Attach the RED and BLACKpower cord conductors
to the outer, BRASScolored terminals on the
terminal block. Tighten both screws securely.
ELEC'r.'CALS,oCK"AZAP,D
Donotmakeasbarpbendorcrimpwirhg/conductor
at connections.
9 Follow manufacturer's guidelines for firmly securing
the strain relief and power cord.
3.0 Reinstall the terminal block cover.
__ Acc_ cover
f_ black
Line 2
(BRASS terminal)
Neutral
(SILVER terminal)
Line 1
(BRASS terminal)
-_ Internal ground
(GREEN screw)
Install
UL-approved
strain relief here
Terminal screw
recovery slot
Ifa terminal screw falls during cord installation, it can
be retrieved in the terminal screw recovery slot below
the access panel. ...............
Move internal ground (WHITE)
wire to neutral (SILVER)
terminal for 4-wRe s
{
GREEN
ground screw
\
Neutral
terminal
neutral wire
GREEN
ground wit
BLACK
power wire
RED power wir
General installation
1 Connect the exhaust duct to the outside exhaust
system, Use of a 4" (102 mm) clamp (item A) is
recommended to connect the dryer to the exhaust
vent system, Use metal foit tape to seal all other
joints,
2 Use a carpenter's level to level your dryer front-to-
back and side-to-side,
3 Use adjustable pliers to adjust the leveling legs so
the dryer is level front-to-rear and side-to-side, and
stable comer-to-corner,
4 Press down on alternate corners and sides and feel
for the slightest movement. Adjust the appropriate
leg(s) so the dryer sits solidly on the floor on ALL
four tegs, Keep the leveling leg extension at a
minimum for best performance of the dryer.
5 Plugthe power cord into a grounded outlet.
..... I1receptacle
any circumstances,
_._ti,tea nce s' Icut ........
grounding prong.j_
Power cord with
3:prong grounded plug
6 Turn on the power at the circuit breaker/fuse box.
7 Read the Use & Care Guide provided with the dryer.
It contains valuable and helpful information that
wilt save you time and money.
8 If you have any questions during initial operation,
please review the "Avoid Service Checklist" in your
Use & Care Guide before calling for service.
9 Placethese instructions in a location near the dryer
for future reference.
Yourdryerisdesignedsothedoorswingmaybereversedatanytimewithoutadditionalparts.Conversionis
accomplishedbytransferringhingesanddoorstriketotheoppositesidesofthecabinet.
I Be sure you have adequate swing area Tools needed:
before reversing door. _ _ %_,
2 You will need a screw driver with a #2 square ELECTRICAL SHOCK HAZARD _, ( \,_ } "*_, :i_
: bit and a pair of pliers. Failure to disconnect power source _,t,, _' ">- X_!_
3 Protect flat work surface such as top of dryer before servicing could result in
or floor near dryer, with a soft cloth or towel, personal injury or even death. Screwdriverwith #2 Adjustable
4 Be sure dryer is unplugged from power source! ......................................................................................................................................................squarebit pliers
! Open door and remove four plugs in the door opening 3 Place door on a towel (front side down) to prevent
opposite the hinges. Retain all parts for use later, scratches to paint or window (if equipped). Remove
unless otherwise noted. (Figure below) all four remaining long hinge screws on edge of door.
Be careful not to scratch the paint.
Observe the "D" stamped on the interior of the hinge
on the door side. When reversed to the other side, this
f--_2: HOLE PLUGS(x4) "D" must be visible after the hinge is remounted.
HINGE SCREW_
"D" STAMPEDON
DOOR SIDE OF
HINGE INTERIOR
2 Begin removing the four short screws that attach the
hinge to the front panel. (Figure Above) Start by only
removing one screw per hinge. Then only loosen the
two remaining screws while firmly holding the door to
prevent damage to hinge, front panel or door. After the
remaining screws are loosened, continue to remove all.
DOOR EDGE
SCREWS(x 4)
DOOR
SCREWS (x 4)
4 Remove the four long screws from edge of door
opposite hinges. (Figure above)
5 Installfourlongscrewssecuringhingetodoor
assemblyinthenewlocation,takenotetoplace
eachhingeincorrectorientation.(Figurebelow)
Theplatewiththestamped"D"ismountedtothedoor.
The"D"mustbevisibleafterthehingeisremounted
andthespineofthehingeshouldbeorientedtoward
thefrontsideofthedoorforcorrectoperation............
DOOREDGE
SCREWS(x4',
"D"STAMPEDONDOOR
SIDEOFHINGEINTERIOR
DOOR HINGE
SCREWS (x 4)
6 Install four long screws into holes that had secured
the hinges. (Figure above)
7 Remove striker and discard. (Figure below)
8 Remove square plug opposite striker. (Figure above)
If plug is damaged during removal, discard and install
new plug (included in literature bag) into hole striker
was just removed from.
9 Install new striker (included in literature bag) into hole
square plug was previously installed in. (Figure below)
i0 Grasping firmly the top of the door, position the door
near the door opening and align the top hinge hole
to the top hole in the front panel door opening. Once
the first short screw is started, attach the second
short screw to the lower hinge. Once both screws
are tightened, install the remaining two short screws.
(Figure below)
HOLE PLUGS(x
ON
DOOR SIDE OF
HINGE INTERIOR
i! Install four plugs into the front panel door opening
where hinges were originally installed. (Figure above)
i2 Close the door and test operation of hinge, strike and
latch.
LP CONVERSION KIT
P/N PCK4200
Gas dryers intended for use in a location supplied with LP
must use a conversion kit prior to installation.
MOBILE HOME INSTALLATION KIT
P/N137067200
Installation in a mobile home requires the use of a
MOBILE HOMEINSTALLATION KIT.
DRYING RACK (FOR USE WITH HODELS EQUIPPED
WITH MOISTURE SENSING BARS)
P/N137067300
Depending on the model you purchased, a drying rack
may have been included in the initial purchase of your
dryer. If your model did not include a drying rack or you
desire another drying rack, you may order one,
UNIVERSAL APPLIANCE WRENCH
P/N137019200
A UNIVERSALAPPLIANCE WRENCHis available to aid in
dryer/washer/pedestal feet adjustment,
TOUCH UP PAINT PENS*
Classic White Touch Up Pen - P/N 5304468812
_Other colors may be available. Contact the source where you
purchased your dryer.
approved by) the manufacturer could result in personal
Technical Sheet/Wiring Diagram:
A wiring diagram and technical data sheet are located
inside the dryer console.
To remove the console faceplate follow the directions
below:
1. Disconnect dryer from electrical source.
2. Remove the two screws toward the top on the back of
the console housing.
3. Insert a small screw driver through each hole on the
back of the console housing and gently press inward
to disengage each upper faceplate retaining tab.
4. Gently lay the console faceplate forward to access
technical/wiring diagram.
5. When finished with repair, return sheet inside console,
ensure lower retaining tabs are in place and snap
faceplate to upper retaining tabs. Reinsert the two
screws removed earlier.
TECH DATA SHEET/
Replacement parts:
Ifreplacementspartsareneeded foryourdryer,contact
the source where you purchased your dryer or refer to
your Use and Care Guide for more information. ELECTRICAL SHOCK HAZARD
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

Frigidaire FFRG1001PW1 Guide d'installation

Catégorie
Laveuses sécheuses
Taper
Guide d'installation
Ce manuel convient également à