EcoFlow RIVER 2 Mode d'emploi

Taper
Mode d'emploi
ECOFLOW RIVER 2
User Manual V1.0
EN
FR
CHT
Disclaimer
Read this user manual carefully before using the product to ensure that you completely
understand the product and can correctly use it. After reading this user manual, keep it properly
for future reference. Improper use of this product may cause serious injury to yourself or others,
or cause product damage and property loss. Once you use this product, it is deemed that you
understand, approve and accept all the terms and content in this document. EcoFlow is not
liable for any loss caused by the user's failure to use the product in compliance with this user
manual.
In compliance with laws and regulations, EcoFlow reserves the right to nal interpretation of
this document and all documents related to the product.This document is subject to changes
(updates, revisions, or termination) without prior notice. Please visit EcoFlow's ofcial website
to obtain the latest product information.
3
Content
Specications
Safety Instructions
EcoFlow App
Product Details
Power On/Off
Charge Your Devices
Charge RIVER 2
What's in the Box
Overview
LCD Screen
AC Charging (Grid Charging)
Solar Charging
Car Charging
1
2
4
4
5
4
6
7
7
8
8
8
9
USB-C Charging 9
FAQ
Additional Features
Troubleshooting
Care and Maintenance
10
10
10
11
12
12
X-Boost
EPS
1
Specications
General Information
Weight Approximately 3.5kg (7.8lbs)
Dimensions 245 x 215 x 145mm (9.6 x 8.5 x 5.7inches)
Capacity 256Wh (20Ah 12.8V )
Wi-Fi (2.4G)
Frequency range :
20M: 2412-2462MHz/40M: 2422-2452MHz
Maximum output power : 0.071W
Bluetooth Frequency range : 2402-2480MHz
Maximum output power : 0.005W
Model EFR600
Input Specifications
AC Input 100V-120V~50Hz/60Hz, 8A Max
Car Charging Input 12V/24V 8A, 100W Max
Solar Charging Input 11-30V 8A, 110W Max
USB-C Input 5/9/12/15/20V 3A, 60W Max
Output Specifications
USB-C Output 5/9/12/15/20V 3A, 60W Max
USB-A Output 5V 2.4A 12W Max per port
DC Output 12.6V 8A, 100W Max
AC Output Pure sine wave, 300W total (600W peak),
120V~50Hz/60Hz*
Battery Specifications
Cell Material LFP battery
Cycle Life 80%+ capacity after 3000 cycles
Operating Temperatures
Optimal Ambient Temperature for Operation 20°C~30°C(68°F to 86°F)
Ambient Temperature for Discharging -10°C~45°C(14°F to 113°F)
Ambient Temperature for Charging 0°C~45°C(32°F to 113°F)
Ambient Temperature for Storage -10°C~45°C (optimal: 20°C~30°C)
14°F to 113°F (optimal: 68°F to 86°F)
*Do not switch the AC output frequency at will, as it may cause some electrical appliances to
stop working.
2
Safety Instructions
WARNING When using this product, the following precautions should be
adhered to:
1. Do not use the product near a heat source, such as a re source or a heating furnace.
2. When using the product, please strictly follow the operating environment temperature
specied in this user manual. If the temperature is too high, it may result in a re or explosion;
if the temperature is too low, the product performance may be severely reduced, or the product
may cease to work.
3. If this product accidentally catches re, we recommend that you use the re extinguishers in
the following order: water or water mist, sand, re blanket, dry powder, and carbon dioxide re
extinguishers.
4. Do not allow this product to come into contact with any liquid. Do not use this product in the
rain or high humidity.
5. It is recommended that you use moisture barrier bags in humid environments (for example,
places by the sea or waterways) to prevent the product from getting wet.
6. If water is found inside the product, or the product is accidentally dropped into water, it must
not be used or turned on again. Please place it in a safe open area, and stay away from it
until it is completely dry. Please do not approach the product before it is dry. Please take anti-
electric shock measures before touching the product. The dried product should not be used or
discarded at will. Please properly dispose of it after contacting Customer Service.
7. Use a dry cloth to clean dirt from the product ports.
8. Do not use this product in an environment with strong static electricity or strong magnetic eld.
9. Do not stack any heavy objects on the product.
10. Store the product in a dry and ventilated place.
11. Keep this product out of reach of children and pets.
12. Do not place the battery in a low air pressure environment, as this may cause flammable
liquids to leak or even an explosion.
13. Do not disassemble or puncture this product in any way with sharp objects.
14. Do not forcibly block the fan during use.
15. Do not touch the product port with wires or other metal objects to avoid short circuit or other
risks.
16. When using or transporting this product, please avoid impact, falls and violent vibrations. In
case of a severe impact, stop using this product immediately and turn off the power.
17. Do not use unofcial components or accessories as this will void the warranty. Consult ofcial
EcoFlow channels if you need to replace any component or accessory.
18. This product is not recommended for powering medical emergency equipment related
to personal safety, including but not limited to medical grade ventilators (hospital CPAP:
Continuous Positive Airway Pressure) or articial lungs (ECMO: Extracorporeal Membrane
Oxygenation). The product can be used to power a home ventilator (home CPAP) that does
Usage
3
not have to be continuously monitored by professionals. Please follow your doctor's instructions
and consult with the manufacturer for restrictions on the use of the equipment. If it is used
for general medical equipment, please be sure to monitor the power status to ensure that the
power does not run out.
19. When in use, power supply products will inevitably generate electromagnetic fields, which
are likely to affect the normal operation of medical implants or personal medical equipment
such as pacemakers, cochlear implants, hearing aids, debrillators etc. If these types of medical
equipment are being used, please contact the manufacturer to inquire about any restrictions on
the use of such equipment. These measures are fundamental to ensure a safe distance between
the medical implants (for example, pacemakers, cochlear implants, hearing aids, debrillators,
etc.) and this product while in use.
20. When the power supply is connected in the normal mode to a refrigerator, the power supply
may be automatically shut down due to the power uctuation property of the refrigerator. If
the refrigerator stores medicines, vaccines or other high-value items, it is highly recommended
that you set the AC output to "Never Turn Off" through the EcoFlow app when connecting the
power supply product to ensure a continuous power supply. Users should pay attention to the
power consumption of the power supply.
21. Do not put ngers or hands into the product.
22. To reduce risk of damage to the electric plug and cord, pull the plug rather than the cord when
disconnecting the power pack.
23. Do not operate the power pack with a damaged cord, plug or output cable.
24. To reduce the risk of electric shock, unplug the power pack form the outlet before attempting
any instructed servicing.
25. Have servicing performed by a qualied repair person using only identical replacement parts.
This will ensure that the safety of the product is maintained.
26. Do not use a battery pack or appliance that is damaged or modied. Damaged or modied
batteries may exhibit unpredictable behavior resulting in re, explosion or risk of injury.
27. Users should not to place the product on the oor, or at a height less than 457 mm (18 inches)
above the oor, when in a repair facility.
28. For long-term storage, please discharge the product every three months (rstly discharge it to
0%, then recharge it to 60%); the product will not be covered by the warranty if it is not charged
or discharged for more than 6 months.
Disposal Guide
1. Whenever possible, please completely discharge the battery of this product before placing
the product in the designated battery recycling bin. This product contains batteries.
Batteries are hazardous chemicals and should not be disposed of in ordinary trash cans.
For details, please follow local laws and regulations on battery recycling and disposal.
2. If the battery cannot be completely discharged due to the failure of the product itself,
please do not dispose of the battery directly in the battery recycling bin, and contact a
professional battery recycling company for further processing.
3. The battery will not start after over-discharge, please dispose of it.
4
EcoFlow App
What's in the Box
1. This product must be grounded. If it should malfunction or break down while charging,
grounding provides a path of least resistance for electric current to reduce the risk
of electric shock. This product is equipped with a power cord that has an equipment
grounding conductor and a grounding plug. The plug must be plugged into an outlet that is
properly installed and grounded in accordance with all local codes ordinances.
2. Improper connection of the equipment grounding conductor is able to result in a risk of
electric shock. Check with a qualied electrician if you are in doubt as to whether the
product is properly grounded. Do not modify the plug provided with the product – if it will
not t the outlet, have a proper outlet installed by a qualied electrician.
Grounding Instructions
SAVE THESE INSTRUCTIONS
Control, monitor and customize your EcoFlow RIVER 2 from
afar with the EcoFlow App.
User Manual &
Warranty Card
Car Charging
Cable
AC Charging
Cable
RIVER 2
5
Overview
Product Details
1. USB-C input/output port
4. DC output switch
7. AC output socket
2. Main power button
5. DC output socket
8. AC output switch
3. USB-A output port (×2)
6. LCD screen
9. X-Stream AC charging input port 10. Fan (do not block)
11. Car/Solar charging input port
6
LCD Screen
Refer to "Troubleshooting" for details.
1. Remaining battery percentage
2. Discharge/Recharge level limitation
3. Remaining charge/discharge time
4. Bluetooth connection
5. Wi-Fi connection
6. AC output
7. Fan
8. High temperature warning
9. Input power
10. Output power
11. Low temperature warning
12. Overload warning
7
Power On/Off
Charge Your Devices
Press the main power button once to turn on the product. The LCD screen lights up and the
main power indicator ashes white. Press and hold the main power button
(for about 3 seconds) to turn off the product, and the LCD screen.
The USB-A and USB-C output ports are automatically turned on once the product is turned on.
Press the "DC output switch" or "AC output switch" once to turn on their corresponding DC/AC
output sockets; press again to turn them off.
When using the AC output socket, make sure that the sum power of all loaded devices
is less than the rated power.
DC ON/OFF AC ON/OFF
1. After the product is turned on, press the main power button once to turn off the
LCD screen.
2. If the product is not used for 5 minutes, it will enter hibernation and the LCD screen
will turn off.
3. When RIVER 2 is charging, it can't be turned off by pressing and holding the main
power button unless the charging cable is unplugged rst.
Short press the
power switch
Short press the
power switch
Short press for power-on/
Long press for power-off
8
Charge RIVER 2
AC charging cable
X-Stream fast charging
360W Max
Fully charged in 1 hour
110W Max
Fully charged in
approximate 3 to 6 hours
1. For AC charging, we recommend that you use a power socket with a capacity of
more than 10A and ensure that the working current of the socket is constantly
greater than 10A.
2. For AC charging, please use the AC charging cable included in the package and plug
the cable directly into a wall outlet instead of an extension socket.
AC Charging (Grid Charging)
Solar Charging
1. The solar charging cable (MC4-XT60 adapter cable) and the solar panel are supplied
separately.
2. When using an EcoFlow solar panel to charge the product, connect them according
to the instructions in the user manual.
3. Before connecting the solar panel, ensure that the output voltage of the solar panel is
less than 30 V to avoid product damage.
Solar charging cable
Solar panel
+
+
+
9
You can recharge the product through the car power outlet. The product supports 12V/24V car
chargers and a maximum charging current of 8A.
To avoid failure to start due to insufcient car battery, use the car charger after the vehicle is
started. In addition, please make sure that the car charger cable is securely connected to the
cigarette lighter.
EcoFlow
takes no responsibilities for any loss or damage caused by failure to follow
instructions.
Car Charging
USB-C charging
60W Max
Fully charged in
approximate 5 hours
100W Max
Fully charged in
as fast as 3 hours
The USB-C charging cable (Type-C plug) and adapter are supplied separately.
Car charging cable
10
As a basic UPS feature, the EPS does not support 0ms switching. Please do not connect
the product to any device that requires 0ms UPS (such as data servers and workstations).
Please test and conrm the compatibility before using the product. We recommend that you
power only one device (with maximum power <600W) at a time and avoid using multiple
appliances at the same time to avoid triggering overload protection. EcoFlow takes no
responsibilities for any device failure or data loss caused by failure to follow instructions.
1. The X-Boost feature is not suitable for appliances with voltage protection (such as precise
instruments).
2. It is suitable for heating and motor-driven devices. Please conduct your own tests to check
whether your devices support X-Boost.
The product supports emergency power supply (EPS). When you connect the grid power to the
AC input port of the product through an AC cable, you can power electrical devices through the
AC output port (AC power will come from the grid instead of the power station in this situation).
In case of a sudden blackout, the product can automatically switch to the battery-powered
supply mode within 30ms.
Additional Features
X-Boost
EPS
The product supports X-Boost. It can power devices rated at up to 600W without incurring
operation failure due to overload protection. Observe the following tips when using the
X-Boost feature:
11
Troubleshooting
If a warning appears during the use of the product and the warning icon persists after
restart, please stop using the product immediately (do not attempt to charge or discharge
it). For problems not covered in the preceding table, please consult EcoFlow customer
service.
Indicator Problem Solution
Flashing Battery discharge
low temperature
Normal operation will resume
automatically when the
battery warms up.
Flashing Battery discharge
high temperature
Normal operation will resume
automatically after the
battery cools down.
Flashing Battery charging
low temperature
Normal operation will resume
automatically after the battery temperature
is restored to above 3°C.
Flashing Battery charging
high temperature
Normal operation will resume
automatically after the
battery cools down.
Flashing AC output
low temperature
Normal operation will resume
automatically when the
product warms up.
Flashing AC output
high temperature
Ensure that the air inlet and outlet of
the product are unobstructed. Normal
operation will resume automatically after
the temperature decreases.
Flashing USB-C or car
charging output
overload
Disconnect overloading devices and
restart the product to resume
normal operation.
Flashing AC output overload
Disconnect overloading devices
and restart the product to
resume normal operation.
The sum power of loaded electrical
appliances must not exceed the rated
power (for the power limit of electrical
appliances in X-Boost mode,
please refer to the X-Boost
feature introduction).
Flashing Charging overload Remove the charging cable and
normal operation will resume
automatically after restart.
Flashing Fan blocked Check whether the fan is blocked
by foreign objects.
Flashing Communication failure
between main
control board and AC
Normal operation will resume
automatically after restart.
12
Care and Maintenance
1. For safety, please do not store the product in temperature higher than 45°C (113°F) or
lower than -10°C (14°F) for a long time.
2. For long-term storage, please recharge the product every three months (rstly discharge
it to 0%, then recharge it to 60%). The product will not be covered by the warranty if it is
not charged or discharged for more than 6 months.
3. If the product has been idle for too long and the battery is severely low, it will enter a deep
sleep protection mode. In such case, please charge the product before using it again.
FAQ
1. What battery does the product use?
High-quality LFP battery.
2. What devices can the product's AC output socket power?
The rated power of the product is 300W and the peak power is 600W. With the X-Boost
feature, the product's AC output sockets can power devices rated at 600W or below.
We recommend that you conrm the power of devices before use, and ensure that the
sum power of all loaded devices is less than the rated power.
3. How do I know how long the product can charge my devices?
The charging time is shown on the product's LCD screen, which can be used to estimate
the charging time of most appliances with stable power usage.
4. How do I know if the product is charging?
During charging, the remaining charging time is shown on the LCD screen. Meanwhile,
the circle indicator around the remaining battery percentage rotates and the input power
is shown.
5. Can I take the product on a plane?
No.
6. Can I switch the frequency of the product?
We recommend that you do not switch the frequency in most cases. If you need to switch the
AC frequency due to special circumstances, please turn on the AC power, and then press and
hold the AC output switch for 10 seconds or use the app to switch frequency.
ECOFLOW RIVER2
Manuel d’utilisation V1.0
Clause de non-responsabilité
Les utilisateurs sont tenus de lire attentivement ce manuel d'utilisation et de s'assurer qu'ils
ont bien compris son contenu avant d'utiliser ce produit. Conservez ce manuel d'utilisation
pour vous y référer en cas de besoin. Toute utilisation incorrecte peut causer des blessures
graves pour l'utilisateur ou d'autres personnes, endommager le produit ou entraîner des pertes
matérielles. Il est considéré que si l'utilisateur utilise ce produit, il comprend, reconnaît et
accepte l'ensemble des termes et contenus du manuel d'utilisation et est responsable de toute
utilisation incorrecte et de toutes les conséquences qui en découlent. Par la présente, EcoFlow
décline toute responsabilité en cas de pertes dues à une utilisation du produit non-conforme au
manuel d'utilisation par l'utilisateur.
Sous réserve du respect des lois et réglementations, notre entreprise a le droit nal d'interpréter
ce document et tous les documents relatifs à ce produit. Toute mise à jour, révision ou
résiliation du contenu de celui-ci, le cas échéant, sera effectuée sans préavis et les utilisateurs
devront consulter le site ofciel d'EcoFlow pour obtenir les dernières informations concernant
le produit.
Contenu
Caractéristiques
Consignes de sécurité
Application EcoFlow
Détails du produit
Mise sous/hors tension
Charge de vos appareils
Charge de la station RIVER 2
Contenu de la boîte
Présentation
Écran LCD
Charge CA (charge du réseau)
Charge solaire
Charge de voiture
Charge USB-C
FAQ
Caractéristiques supplémentaires
Dépannage
Entretien et maintenance
X-Boost
Alimentation électrique de secours
1
2
4
4
5
4
6
7
7
8
8
8
9
9
10
10
10
11
12
12
1
Spécications
Informations générales
Poids Environ 3,5 kg(7.8lbs)
Dimensions 245*215*145 mm(9.6 x 8.5 x 5.7inches)
Capacité 256 Wh (20 Ah 12,8 V )
Wi-Fi(2.4G)
Gamme de fréquences :
20M: 2412-2462MHz/40M: 2422-2452MHz
Puissance de sortie maximale: 0.071W
Bluetooth Gamme de fréquences : 2402-2480MHz
Puissance de sortie maximale : 0.005W
Modèle EFR600
Spécifications d’entrée
Tension d’entrée CA 100V-120V~50Hz/60Hz, 8A Max
Entrée de charge de voiture 12 V/24 V 8 A, 100 W max.
Entrée de charge solaire 11-30 V 8 A, 110 W max.
Entrée USB-C 5/9/12/15/20 V 3 A, 60 W max.
Spécifications de sortie
Sortie USB-C 5/9/12/15/20 V 3 A, 60 W max.
Sortie USB-A 5 V 2,4 A 12 W max. par port
Sortie de chargeur de voiture 12,6 V 8 A, 100 W max.
Sortie CA Onde sinusoïdale pure, total 300 W (pic à 600 W)
120V~50Hz/60Hz*
Spécifications de la batterie
Matériau de la batterie Batterie lithium au phosphate de fer
Cycle de vie Après 3000 cycles, la capacité restante est
toujours supérieure à 80 %
Température de fonctionnement
Température ambiante optimale pour le
fonctionnement 20 - 30
Température ambiante pour la décharge -10 - 45
Température ambiante pour la charge 0 - 45
Température ambiante pour le stockage -10 - 45 (optimal: 20 - 30)
Ne pas modier la fréquence de sortie CA de façon intempestive, sans quoi certains appareils
électriques pourraient être inutilisables.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

EcoFlow RIVER 2 Mode d'emploi

Taper
Mode d'emploi

dans d''autres langues