Tetra PowerMAX 12V Wet Location LED Signage Guide d'installation

Taper
Guide d'installation
Wet Location PowerMAX
LED Lighting System
Installation Guide
SIGN178 | GE2027-8883
GEPM71-W1, GEPM50-W1, GEPM41-W1, GEPM32-W1
RETROFIT SIGN CONVERSION LED KIT FOR USE ONLY IN
ACCORDANCE WITH KIT INSTRUCTIONS.
KIT IS COMPLETE ONLY WHEN ALL PARTS REQUIRED BY
THE INSTRUCTIONS ARE PRESENT.
TROUSSE DE CONVERSION À DEL POUR LA
MODERNISATION DES ENSEIGNES
À UTILISER CONFORMÉMENT AU GUIDE D’INSTALLATION.
Save These Instructions
Use only in the manner intended by the
manufacturer. If you have any questions, contact the
manufacturer.
For the latest North American install guides for your product go to: https://products.LED.com/led-signage-lighting
For the latest European install guides for your product go to: https://products.LED.com/eu
BG Българската версия на инструкциите за инсталаця и
информация за безопасност могат да бъдат намерени
на следния адрес: https://products.LED.com/eu
CS Návod k montáží a bezpečnostní informace v češtině
najdete zde: https://products.LED.com/eu
DA Den danske version af installationsvejledningen og
sikkerhedsoplysninger kan findes på følgende placering:
https://products.LED.com/eu
DE Die deutsche Version der Installationsanleitung und
Sicherheitsinformationen finden Sie in folgendem Verzeic:
https://products.LED.com/eu
EL Μπορείτε να βρείτε την ελληνική εκδχή των οδηγιών
νγκατάστασης και των πληροφοριών ασφάλειας στην
εξής τοποθεσία: https://products.LED.com/eu
ES La versión española de las instrucciones de instalación y
la información sobre seguridad puede encontrarse en la
siguiente ubicación: https://products.LED.com/eu
ET Eestikeelse paigaldusjuhendi ja ohutusnñuded leiate
aadressilt: https://products.LED.com/eu
FI Asennusohjeiden ja turvallisuustietojen suomenkielinen
versio löytyy seuraavasta paikasta: https://products.LED.
com/eu
FR La version française des instructions d’installations
et information de sécurité est disponible à l’adresse
suivante: https://products.LED.com/eu
HR Hrvatska verzija priručnika za ugradnju i sigurnosnih
informacija nalazi se na sljedečoj lokaciji: https://products.
LED.com/eu
HU A telepítési útmutató és a biztnosági információk magyar
nyelvű változata az alábbi címen található: https://
products.LED.com/eu
IT La versione italiana del manuale di installazione e
sicurezza può essere reperita nella seguente sezione:
https://products.LED.com/eu
LT Lietuvišką diegimo instrukcijos ir saugos informacijos
versiją galima rasti šioje vietoje: https://products.LED.
com/eu
LV Uzstādīšanas instrukciju un drošības informāciju latviešu
valodā var atrast šeit: https://products.LED.com/eu
NL De Nederlandse versie van de installatie-instructies en
veiligheidsinformatie kan op de volgende locatie worden
gevonden: https://products.LED.com/eu
PL Polską wersję instrukcji instalacji oraz informacje
dotyczące bezpieczeństwa można znaleźć w następującej
lokalizacji: https://products.LED.com/eu
PT A versão em Português das instruções de instalação e
das informações de segurança pode ser encontrada na
seguinte localização: https://products.LED.com/eu
RO Versiunea în limba română a instrucţiunilor de instalare
şi a informaţiilor de siguranţă pot fi găsite la: https://
products.LED.com/eu
SV Ni hittar den svenska versionen av
installationsanvisningarna och säkerhetsinformationen på
följande plats: https://products.LED.com/eu
SL Previdnostna opozorila in varnostne informacije so na
zadnji strani vodnika za namestitev. Pred začetkom
namestitve izdelka jih skrbno preberite: https://products.
LED.com/eu
SK Slovenskú verziu montažnej príručky a bezpečnostnŷch
instrukcií nájdete na nasledujúcej lokalite: https://
products.LED.com/eu
EN
1212
Volt
BEFORE YOU BEGIN
Read these instructions completely and carefully.
Prepare Electrical Wiring
Electrical Requirements
Acceptable for use in dry, damp and wet locations.
The grounding and bonding of the LED Driver shall be done in
accordance with National Electric Code (NEC) Article 600.
Follow all National Electric Codes (NEC) and local codes.
These products are only suitable for connection to a circuit
from a Class 2 power source.
These products have not been evaluated for use when
connected to a power source that does not comply with Class
2 voltage and energy limited supplies.
FOR UL ONLY
Tetra® Wet Location PowerMAX Installation Guide
2
WARNING / AVERTISSEMENT
RISK OF ELECTRIC SHOCK
Turn power off before inspection, installation or removal.
Properly ground power supply enclosure.
RISK OF FIRE
Use only suitably approved wire for input/output
connections. Minimum size 18 AWG (0.82mm2)
Follow all local codes.
Not to be submerged or used in a marine environment.
RISQUES DE DÉCHARGES ÉLECTRIQUES
Coupez l’alimentation avant l’inspection, l’installation ou le déplacement.
Assurez-vous de correctement mettre à terre l’alimentation électrique.
RISQUES D’INCENDIE
N’utilisez que des fils approuvés par UL pour les entrées/sorties de connexion. Taille
minimum 18 AWG (0.82mm2)
Respectez tous les codes locaux.
Ne pas submerger ou installer dans un environnement marin.
UL WARNING / AVERTISSEMENT UL
RISK OF FIRE OR ELECTRIC SHOCK
LED Retrofit Kit installation requires knowledge of sign
electrical systems. If not qualified, do not attempt installation.
Contact a qualified electrician.
Install this kit only in host signs that have been identified in the
installation instructions and where the input rating of the retrofit
kit does not exceed the input rating of the sign.
Installation of this LED retrofit kit may involve drilling or
punching of holes into the structure of the sign. Check for
enclosed wiring and components to avoid damage to wiring
and electrical parts.
Do not make or alter any open holes in an enclosure of wiring
or electrical components during kit installation.
RISQUE D’INCENDIE OU DE CHOC ÉLECTRIQUE
L’installation de l’équipement de remplacement DEL exige Ia connaissance
des systèmes électriques pour enseignes. Si non qualifié, ne tentez pas
d’installation. Veuillez contacter un électricien qualifié.
Risque d’incendie ou de choc électrique. Installez cet ensemble seulement dans des
enseignes hôtes qui ont été identifiés dans les instructions d’installation et dont la
capacité d’entrée de l’ensemble ne dépasse pas la capacité d’entrée de l’enseigne.
L’installation de cet équipement de remplacement DEL peut impliquer le
perçage ou le poinçonnage de trous dans la structure du panneau Vérifiez le
câblage et les composants inclus pour éviter d’endommager le câblage et les
composants électriques.
Ne pas faire ou modifier les trous ouverts dans une enceinte de câblage ou de
composants électriques pendant l’installation de cet équipement de remplacement DEL.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference
to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to
correct the interference at his own expense.
This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005 du Canada.
Components
This product is intended solely for the use of non-residential signaCurrent and is not intended for use in any other applications.
Conforms to the following standards: IP66 rated
TC Measure Point
UL approved 18 AWG supply wire (0.82 mm2)
UL approved 22-14 AWG twist-on wire connectors (0.33 - 2.08 mm2)
or 18-14 AWG In-line/IDC connectors (0.82 - 2.08 mm2)
#6 or #8 (M3 or M4) screws, 1/8 inch (3.2 mm) rivets, or electronic
grade silicone or equivalent
Tetra® 12 Volt Power Supply
Weather box GEXNWB2 (optional)
Tetra® Wet Location PowerMAX LED Modules
1
12
2
3
3
4
45
5
6
6
Tetra® Wet Location PowerMAX Installation Guide
3
Measure and cut Tetra®
LED strip to the appropriate
length for each letter. Cuts
can be made between any of
the modules.
Remove tape backing and
stick LED modules into place.
Continue until you have
reached the end of the strip.
Clean and remove all debris
from the inside of the
channel letter. Replace sign
face.
Drill a 1/4” (6.4 mm) hole
near the LED strip and
grommet the hole for supply
wire access.
Use rivets, screws, or silicone
to secure at least every
fifth LED module within the
channel letter. Use #6 (M3)
or #8 (M4) pan headed metal
screws, 1/8-inch (3.2 mm)
rivets, or silicone.
Clean and remove all debris
from the inside of the channel
letter before you begin.
NOTE: For halo-lit applications LED modules should be mounted on UL
recognized clear acrylic or polycarbonate. The light output from the LED
system should be directed back into the sign enclosure. This will allow for
uniform backlighting of the sign and will provide simple mounting.
Layout Modules
Electrical Connections
Connect LED strips using in-line (IDC) connectors
or twist-on wire connectors.
Must cap all exposed wires with appropriate
wire connectors.
Cap wires
Red Stripe (+)
White (-)
2
5
2
1
4
1
3
6
Tetra® Wet Location PowerMAX Installation Guide
4
Run a wire from the power supply to each channel
letter and connect to the first LED module on the
strip.
Must be used with Tetra® 12 Volt Power Supplies.
To power
supply
Red (+)
Red Stripe (+)White (-)
Connect the red stripe wire (+) of the LED strip
to the red wire (+) of the power supply. Connect
the white wire (-) of the LED strip to the black or
blue wire (-) of the power supply.
NOTE: All electrical connections should be
made within the letter.
Power
Supply
To Tetra LED System
Red (+) Black or blue (-)
Black or blue (-)
1. (Existing Signs Only) Prior to installation, survey the site for information regarding power and accessibility inside and outside the
building. Ensure that the branch circuit supplying the existing transformer or ballast will be within the voltage ratings of the new LED
power supply, and have a current rating not exceeding 20A, or that permitted by applicable local, state, or country electrical codes
(whichever is less).
2. (Existing Signs Only) Remove the existing lighting equipment to be replaced, such as neon tubing or fluorescent tubes; and
associated transformers and ballasts. Care should be taken not to break the existing neon or fluorescent tubes. NOTE: Follow all
federal and local regulations when disposing of neon tubing, fluorescent tubes, transformers and ballasts.
3. (Existing Signs Only) If removal of the existing lighting equipment eliminates the disconnect switch, as required by applicable
local, state, or country electrical codes; a new disconnect switch must be installed.
4. (Existing Signs Only) Repair and seal any unused openings in the electrical enclosure. Openings greater than 12.7-mm (1/2-in)
diameter require a metal patch secured by screws or rivets and caulked with non-hardening caulk. Smaller openings may be sealed
with non-hardening caulk.
5. (Existing Signs Only) A clean and dry mounting surface ensures optimum adhesion if the self-adhesive method of mounting is
chosen. Follow the manufacturer’s directions when using a non-oil based solvent, such as rubbing alcohol to clean the surface area
where you intend to mount the module. Before installing, ensure the surface is dry.
6. Using the layout guidelines above, determine required number of LED modules required to illuminate the sign.
7. A Tetra® 24VDC Class 2 Power Supply, as listed below, must be used with this retrofit kit. Using the Maximum Loading chart below,
determine the number of Tetra® Class 2 Power Supplies required to power the number of LED modules required to illuminate the
sign, so as not to overload the Tetra® Class 2 Power Supply chosen.
8. Follow the instructions above to properly mount the LED modules.
9. Connect the DC output of the power supply to the LED modules using the Electrical Connections instructions above.
10. Connect the power unit to the supply in accordance with the applicable local, state, and country electrical codes, and the instructions
found in the power supply installation guide.
11. If required, the disconnect switch shall be installed by qualified personnel, in accordance with applicable local, state, and country
electrical codes.
OPTIONAL
A Weather Box (GEXNWB2) may be used
to house and seal Class 2 connections as
described below:
A) Insert wire connectors into weather box. Fill
with electrical grade silicone and close box.
B) Secure the weather box using a #6 or #8
(M2 or M3) screw.
Weather box
can be painted
Light engine
A B
FOR UL ONLY
Retrofit Instructions
43
Tetra® Wet Location PowerMAX Installation Guide
18 AWG/0.82 mm2
Supply Wire 16 AWG/1.31 mm2
Supply Wire 14 AWG/2.08 mm2
Supply Wire 12 AWG/3.31 mm2
Supply Wire
25W Power Supply 120 ft./36.6 m
60W Power Supply 20 ft./6.1 m 30 ft./9.1 m 50 ft./15.2 m 86 ft./26.2 m
180W Power Supply 20 ft./6.1 m 30 ft./9.1 m 50 ft./15.2 m 86 ft./26.2 m
Tips
For optimal light uniformity in halo-lit applications the Tetra® LED modules should be mounted on UL recognized plastic and the light
output from the Tetra® LED system should be directed back into the sign enclosure. This will allow for uniform backlighting of the sign
and will provide simple mounting for the Tetra® LED system.
A best practice for the supply wire at the point at which it is brought into the sign is to have a drip loop on the inside of the letter to
keep water from collecting on the Tetra® LED strip.
These products are not required to be enclosed or protected from weather.
SKU Rating 25W Power Supply
Note: Load shall not exceed 2A
60W Power Supply
Note: Load shall not exceed 5A
180W Power Supply
Note: Load shall not exceed 5A per
each (of 3) output channels
GEPM71-W1
GEPM50-W1
GEPM41-W1
GEPM32-W1
12VDC
110mA/module
1.32W/module
16 modules/10 ft. (3.25m) 42 modules/28 ft. (8.53 m)
42 modules/28 ft. (8.53 m)
per output channel
126 modules/84 ft. (25.60 m)
per power supply
Troubleshooting
Symptom Solution
All letters are OFF Check AC input connection and/or check circuit breaker.
Check wire connection(s) at the Tetra® LED System and power supply for improper termination(s) or short
circuits. Properly terminate or replace the wire connection(s).
Check that connections are the red striped wire (+) of the LED strip to the red wire (+) of the power supply
and the white wire (-) of the LED strip to the black or blue wire (-) of the power supply.
Some LEDs
appear dim
Ensure the overall length of the Tetra® LED System does not exceed the maximum load.
Ensure the length of supply wire is equal to or below the recommended remote mounting distance.
Some of the letters are
not illuminated
Check wire connection(s) at the Tetra® LED System and power supply for improper termination(s) or short
circuits. Properly terminate or replace the wire connection(s).
Check that connections are the red striped wire (+) of the LED strip to the red wire (+) of the power
supply and the white wire (-) of the LED strip to the black or blue wire (-) of the power supply.
Shadows Re-route supply wire and secure to the back of the can with silicone. Adjust wire connector orientation
so that it does not cover any LEDs.
Adjust LED layout to ensure uniformity of illumination on the face of the letter.
Maximum Loading per Tetra 12 VDC Power Supply
Maximum Remote Mounting Distance
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 5 of 5
(Rev 06/10/22)
SIGN178 | GE2027-8883
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Tetra PowerMAX 12V Wet Location LED Signage Guide d'installation

Taper
Guide d'installation