Monogram ZV855SPSS Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation

Ce manuel convient également à

Installation
Instructions
Island Vent Hood
ZV850, ZV855
Hotte Aspirante Îlot
Instructions d’installation
La section française commence à la page 22
Campana de ventilación en isla
Instrucciones de instalación
La sección en español empieza en la página 43
2
Safety Information
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT³Save these instructions for
local inspector’s use.
IMPORTANT³Observe all governing codes
and ordinances.
Note to Installer³ Be sure to leave these
instructions with the Consumer.
Note to Consumer³ Keep these instructions
with your Owner’s Manual for future reference.
Skill Level³Installation of this appliance requires
basic mechanical and electrical skills.
Completion Time³WR+RXUV
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not
covered under the warranty.
)RU0RQRJUDPORFDOVHUYLFHLQ\RXUDUHDFDOO
)RU0RQRJUDPVHUYLFHLQ&DQDGDFDOO
)RU0RQRJUDP3DUWVDQG$FFHVVRULHVFDOO
CAUTION:
Due to the weight and size of these vent hoods and
to reduce the risk of personal injury or damage to the
product, TWO PEOPLE ARE REQUIRED FOR PROPER
INSTALLATION.
WARNING:
To reduce the risk of fire or electrical shock, do not
use this range hood with any external solid-state speed
control device. Any such alteration from original factory
wiring could result in damage to the unit and/or create
an electrical safety hazard.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
WARNING: TO REDUCE THE RISK OF
FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended
by the manufacturer. If you have any questions,
contact the manufacturer.
B. Before servicing or cleaning the unit, switch
the power off at the service panel and lock the
service disconnecting means to prevent the power
from being switched on accidentally. When the
service disconnecting means cannot be locked,
securely fasten a prominent warning device,
such as a tag, to the service panel.
CAUTION: FOR GENERAL VENTILATING
USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS
MATERIALS, EXPLOSIVE MATERIALS OR VAPORS.
WARNING: TO REDUCE THE RISK OF
FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
Installation work and electrical wiring must be done
by qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction.
Sufficient air is needed for proper combustion
and exhausting of gases through the flue (chimney)
of fuel burning equipment to prevent back-drafting.
Follow the heating equipment manufacturer’s
guidelines and safety standards, such as those
published by the National Fire Protection Association
(NFPA), the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE) and the local
code authorities. When applicable, install any makeup
(replacement) air system in accordance with local
building code requirements.
Visit GEAppliances.com
for available makeup air solutions.
When cutting or drilling into walls or ceilings, do not
damage electrical wiring and other hidden utilities.
Ducted systems must always be vented
to the outdoors.
Local codes vary. Installation of electrical connections
and grounding must comply with applicable codes.
In the absence of local codes, the vent should be
installed in accordance with National Electrical Code
ANSI/NFPA 70-1990 or latest edition.
CAUTION: To reduce risk of fire and to
SURSHUO\H[KDXVWDLUEHVXUHWRGXFWDLURXWVLGH³GRQRW
vent exhaust air into spaces within walls or ceilings or
into attics, crawl spaces or garages.
READ AND SAVE THESE INSTRUCTIONS
Design Information
MODELS AVAILABLE
Model ZV850
Model ZV855
These hoods may be installed to vent to the outdoors,
or they may be installed for recirculating operation.
All necessary parts for recirculating operation are
supplied with the hood. No kits required.
These vent hoods can be installed over any 30
or 36
Monogram electric or gas cooktop except Monogram
Professional cooktops or ranges larger than 30”.
Reversible duct covers accommodate recirculating
operation.
The telescopic duct covers conceal the ductwork
running from the top of the hood to the ceiling.
The supplied duct cover is sized to reach ceiling heights
over 8 feet. See the table on page 8.
PRODUCT DIMENSIONS AND CLEARANCES
The vent hood must be installed 24 minimum and
30
maximum above the cooking surface.
NOTE: Installation height should be measured from
the cooking surface to the lowest part of the hood.
=;6366'XFW&RYHU$FFHVVRU\
This accessory is available for installation with ceiling
heights
of
8
Ļ
7
to over 10 feet.
See the table on page 8.
The duct cover accessory must be on-site with the
hood at the time of installation.
24” Minimum
30” Maximum
36" Minimum
*Height
to Ceiling
8-1/4"
27-1/2”
35-3/8ļ (excluding utensil rods)
36-1/2ļ (including utensil rods)
CONTENTS
Design Information
Models Available ................................................................................ 3
Product Dimensions ......................................................................... 3
Advance Planning
Ductwork Planning .......................................................................... 4
Ceiling Framing for Adequate Support .................................. 4
Installation Preparation
Duct Fittings ......................................................................................... 5
Power Supply ...................................................................................... 6
Tools and Materials Required ...................................................... 6
Remove the Packaging ................................................................. 7
Check Installation Hardware ...................................................... 7
Determine Installation Height ..................................................... 8
Install Ceiling Support Structure .........................................9–11
Installation Instructions
Installation – Vented to the Outside ...............................12–16
Step 1, Mount Template ...............................................................12
Step 2, Install Upper Support Frame ......................................12
Step 3, Install Lower Support Frame ......................................12
Step 4, Secure Wiring ....................................................................13
Step 5, Size and Install Ductwork ............................................13
Step 6, Install Decorative Duct Covers ..................................14
Step 7, Install Hood ........................................................................15
Step 8, Connect Electrical ............................................................15
Step 9, Slide Duct Cover
Down, Install Side Utensil Rods ................................................15
Step 10, Install Filters.....................................................................16
Step 11, Finalize Installation.......................................................16
Installation Instructions
Installation – Recirculating .................................................17–21
Step 1, Mount Template ...............................................................17
Step 2, Install Upper Support Frame ......................................17
Step 3, Install Lower Support Frame ......................................18
Step 4, Secure Wiring ....................................................................18
Step 5, Size and Install Ductwork ............................................18
Step 6, Install Decorative Duct Covers ..................................19
Step 7, Install Hood ........................................................................20
Step 8, Connect Electrical ............................................................20
Step 9, Slide Duct Cover
Down, Install Side Utensil Rods ................................................20
Step 10, Install Filters.....................................................................21
Step 11, Finalize Installation.......................................................21
3
Advance Planning
DUCTWORK PLANNING
The hood is designed to be vented vertically
through the ceiling. Use locally supplied elbows
to vent horizontally through the rear wall.
Determine the exact location of the vent hood.
Plan the route for venting exhaust to the outdoors.
Use the shortest and straightest duct route
possible. For satisfactory performance, duct run
should not exceed 100Ļ equivalent length for any
duct configurations.
Refer to “Duct Fittings” chart to compute the
maximum permissible length for duct runs to
the outdoors.
Use rigid metal ductwork only.
This vent hood must use 6 round duct. The
6 round duct can transition to 3-1/4 x 10
or3-1/4x 12.
Install the house duct to run horizontally between
ceiling joists or straight up through the roof.
Install a wall or roof cap with damper at the
exterior opening. Order the wall or roof cap
and any transition and length of duct needed
in advance.
When applicable, install any makeup (replacement)
air system in accordance with local building code
requirements.
Visit GEAppliances.com for available
makeup air solutions.
WARNING: TO REDUCE THE RISK
OF FIRE, USE ONLY RIGID METAL DUCTWORK.
CEILING FRAMING FOR ADEQUATE
SUPPORT
These vent hoods are heavy. Adequate structural
support must be provided. The ceiling structure
must be capable of supporting the weight of the
hood and any inadvertent user contact loads
(approximately 200 pounds). The hood support
frame will be supported by 2 x 4 minimum cross-
framing.
Installation will be easier if the vent hood is
installed before the cooktop or countertop below
is installed.
4
Accessory Duct Cover
A duct cover accessory may be required for your
installation, depending on ceiling height.
5
DUCT FITTINGS
This Hood Must Use an
Round Duct. It Can
7UDQVLWLRQWR[
RU[ Duct.
Use this chart to compute
maximum permissible lengths
for duct runs to outdoors.
NOTE: Do not exceed maximum
permissible equivalent lengths!
Maximum duct length:
100 foot for range hoods.
Flexible ducting:
If flexible metal ducting is used,
all the equivalent feet values in
the table should be doubled.
The flexible metal duct should
be straight and smooth and
extended as much as possible.
DO NOT use flexible plastic
ducting.
NOTE: Any home ventilation
system, such as a ventilation
hood, may interrupt the proper
flow of combustion air and
exhaust required by fireplaces, gas
furnaces, gas water heaters and
other naturally vented systems.
To minimize the chance of
interruption of such naturally
vented systems, follow the
heating equipment manufacturer’s
guidelines and safety standards
such as those published by NFPA
and ASHRAE. When applicable,
install any makeup (replacement)
air system in accordance with
local building code requirements.
Visit GEAppliances.com for available
makeup air solutions.
Installation Preparation
Total Duct Run
* Actual length of straight duct plus duct fitting
equivalent. Equivalent length of duct pieces are
based on actual tests conducted by GE Evaluation
Engineering and reflect requirements for good
venting performance with any ventilation hood.
Total
Equivalent Quantity Equivalent
Duct Piece Dimensions Length* Used Length
Round, 1 ft. (per
straight foot length)
3-1/4 x 10 1 ft. (per
straight foot length)
90° elbow 12 ft.
45° elbow 7 ft.
3-1/4 x 10 14 ft.
3-1/4 x 12 10 ft.
90° elbow
3-1/4 x 10 8 ft.
3-1/4 x 12 6 ft.
45° elbow
3-1/4 x 10 33 ft.
3-1/4 x 12 24 ft.
90° flat elbow
6 round to 2 ft.
rectangular
Rectangular to 8 2 ft.
round
3-1/4 x 10 4 ft.
3-1/4 x 12 4 ft.
6 round to rectangular
transition 90° elbow
3-1/4 x 10 4 ft.
3-1/4 x 12 4 ft.
Rectangular to 6round
transition 90° elbow
Round wall cap 24 ft.
with damper
3-1/4 x 10 24 ft.
3-1/4 x 12 18 ft.
Rectangular wall cap
with damper
Round roof cap 33 ft.
Masking
tape
Gloves
Utility knife
6
POWER SUPPLY
IMPORTANT – (Please read carefully)
WARNING:
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED.
Remove house fuse or open circuit breaker before
beginning installation.
Do not use an extension cord or adapter plug with
this appliance. Follow National Electrical Code or
prevailing local codes and ordinances.
Electrical supply
This vent hood must be supplied with 120V, 60Hz,
and connected to an individual, properly grounded
branch circuit, and protected by a 15- or 20-amp
circuit breaker or time-delay fuse.
• Wiring must be 2-wire with ground.
If the electrical supply does not meet the above
requirements, call a licensed electrician before
proceeding.
Route house wiring as close to the installation
location as possible. Route additional length from
ceiling joists to reach the junction box on the
hood.
Connect the wiring to the house wiring in
accordance with local codes.
Grounding instructions
The grounding conductor must be connected to
a ground metal, permanent wiring system, or an
equipment-grounding terminal or lead on the hood.
WARNING: The improper connection
of the equipment-grounding conductor can result
in a risk of electric shock. Check with a qualified
electrician or service representative if you are in
doubt whether the appliance is properly grounded.
TOOLS AND MATERIALS REQUIRED
(NOT SUPPLIED)
Pliers
Wire cutter/stripper
Metal snips
Spirit level
Aluminized
duct tape
Safety glasses
120V, 60Hz. 15- or 20-Amp,
2-wire with ground, properly
grounded branch circuit
Stepladder
Saber saw or keyhole saw
Phillips screwdriver
Strain relief for
junction box
6 round metal
duct, length to
suit installation
Hammer
Flashlight
UL-listed wire nuts
Pencil and tape measure
Installation Preparation
Electric drill with 5/32 bits,
#2 Phillips and 7/16 socket
10 mm wrench
Plumb
REMOVE THE PACKAGING
CAUTION: Wear gloves to protect
against sharp edges.
The vent hood is packed with the duct cover and
support frames.
Remove the hood, parts and packaging.
Remove junction box cover.
Install strain relief onto junction box cover
(not supplied).
NOTE: Additional tools, materials and hardware are
required to construct your ceiling support.
Check Installation Hardware
Locate the hardware accessory bag packed with the
hood and check contents.
Front of Hood
Template
4 Hex-head
wood lag
screws
(6 mm x
2-1/2 or 1/4
x 2-1/2)
2 Stop screws
(One is in the service
manual envelope.
Leave that screw in
the envelope.)
4 Flat
washers
3 Stainless
steel grease filters
Decorative
duct covers
2 Phillips-head
duct cover
screws
2 Utensil rods with 4 machine screws
7
Installation Preparation
4 (10 mm) Nuts
and lock
washers
Support
frames with 8
screws and 8
washers
8 Frame
attachment
screws with
washers (attached
to accessory
support frames)
Mounting screw holes
Additional Parts for Recirculating Operation
3 Charcoal filters
Air deflector with upper
duct connector and 4
small flat-head screws
Installation Preparation
DETERMINE INSTALLATION HEIGHT
Telescopic duct covers are provided to conceal
the ductwork running to the ceiling.
This hood can be installed for vented or
recirculating operation. All necessary parts are
shipped with the hood.
NOTE: Installation height should be measured from
the cooking surface to the bottom of the hood.
The vent hood must be installed 24 min. and
30 max. above the cooking surface. The hood
installation height, from the cooking surface to the
bottom of the hood, depends upon ceiling height
and duct cover limitations.
24” Minimum
30” Maximum
36" Minimum
DUCT COVER DIMENSIONS
=;6366'XFW&RYHU$FFHVVRU\
The accessory is available for installation with ceiling
heights
of
8
Ļ
7
to
over 10 feet. This accessory
consists of two 26-1/4 duct covers and one 31
upper support frame piece.
*Possible *Possible
VENTED RECIRCULATING
Ceiling Installation Installation
Height Height Height
7 Ļ11 24 24
8Ļ 24 to 25 24 to 25
8Ļ 1 24 to 26 24 to 26
8Ļ 2 25 to 27 24 to 27
8Ļ3 26 to 28 24 to 28
8Ļ 4 27 to 29 24 to 29
8Ļ 5 28 to 30 24 to 30
8Ļ 6 29 to 30 25 to 30
8Ļ 7 30 26 to 30
8Ļ 8 27 to 30
8Ļ 9 28 to 30
8 Ļ 10 29 to 30
8 Ļ 11 30
8Ļ 7 24 24
8Ļ 8 24 to 25 24 to 25
8Ļ 9 24 to 26 24 to 26
8 Ļ 10 24 to 27 24 to 27
8 Ļ 11 24 to 28 24 to 28
9Ļ 24 to 29 24 to 29
9Ļ 1 24 to 30 24 to 30
9Ļ 2 24 to 30 24 to 30
9Ļ 3 24 to 30 24 to 30
9Ļ 4 24 to 30 24 to 30
9Ļ 5 24 to 30 24 to 30
9Ļ 6 24 to 30 24 to 30
9Ļ 7 24 to 30 24 to 30
9Ļ 8 25 to 30 24 to 30
9Ļ 9 26 to 30 24 to 30
9 Ļ 10 27 to 30 24 to 30
9 Ļ 11 28 to 30 25 to 30
10Ļ 29 to 30 26 to 30
10Ļ 1 30 27 to 30
10Ļ 2 28 to 30
10Ļ 3 29 to 30
10Ļ 4 30
*Based on 36 countertop height.
8
ACCESSORY ZX90010 Lower Duct 26.25
 Upper Duct 26.25
ZX8510SPSS – ACCESSORY DUCT COVERS
ACCESSORY ZX90010
Upper Frame 31

 Supplied Lower Frame
ZX8510SPSS – ACCESSORY UPPER FRAME
Lower Duct 18
Upper Duct 18
Lower Frame 20.75

Upper Frame 20.75
ZV850/ZV855
Installation Heights
9-7/16
15-3/4
SUPPLIED FRAME
SUPPLIED DUCT COVERS
9
Installation Preparation
Plan the Location of the Hood and Ductwork
Use a plumb bob to check the location.
The countertop/cooktop below the hood
must be centered with the hood.
The hood should extend beyond the front and rear
edge of the cooking appliance.
The duct in the ceiling must be centered over
the cooktop.
CONSTRUCT CEILING SUPPORT
Top view – ceiling joists parallel to front of hood
16” Joist
spacing
8-3/4”
6” Duct
Front
of
hood
2x4 Cross-framing
wood supports
Cooktop
outline
Align duct
to center
of cooktop
Ceiling Support Structure
At the hood location, install cross-framing between
ceiling joists as shown. (2x4 wood supports
are required to support the weight of the hood.)
Arrange cross-framing in the ceiling to suit
the existing structure.
Your ceiling joists will be like one of the following
examples.
EXAMPLE A
Align with
center of
cooktop
Install cross-framing symmetrically
over duct/cooktop centerline
7-5/8”
Top view – ceiling joists run perpendicular to front of hood
Top view – ceiling joists at angle to front of hood
CONSTRUCT CEILING SUPPORT (Continued)
16”
Joist
spacing
8-3/4”
6
Duct
Front
of
hood
2x4 Cross-
framing wood
supports
Cooktop
outline
Align duct
to center
of cooktop
16
Joist
spacing
6
Duct
Cooktop
outline
Align duct
to center
of cooktop
EXAMPLE B
EXAMPLE C
Front
of hood
7-5/8”
2x4 Cross-
framing wood
supports
Install cross-framing symmetrically
over duct/cooktop centerline
7-5/8”
10
Installation Preparation
8-3/4”
Install cross-framing
symmetrically over
duct/cooktop centerline
11
Installation Preparation
CONSTRUCT CEILING SUPPORT (Continued)
Ductwork for Installations Vented to the Outdoors
Use the shortest and straightest duct route possible.
For satisfactory performance, duct run should not
exceed 100 feet equivalent length for any duct
configuration.
Refer to “Duct Fittings” chart to compute the
maximum permissible length for duct runs to the
outdoors.
This vent hood must use 6 round rigid duct.
WARNING: TO REDUCE THE RISK
OF FIRE, USE ONLY RIGID METAL DUCTWORK.
Install the house ductwork to run horizontally
between ceiling joists or straight up through the
roof.
Finish the Ceiling
Finish the ceiling surface. Be sure to mark location
of the ceiling joists and cross framing. Check to be
sure the ceiling is level; use shims if necessary.
Secure each 2 x 4 block with at least four (4), #10
wood screws, 3 long (not supplied). Use 8 wood
screws total for the two supports.
The cross framing must be accurately aligned
to assure correct positioning of the hood.
The cross framing must be level in all directions.
Check with a spirit level and adjust if necessary.
IMPORTANT: The ceiling structure must be capable
of supporting the weight of the hood (approximately
200 pounds) and any inadvertent user contact loads.
The hood support frame will be supported by the
2 x 4 cross framing.
6”
Duct
Ceiling joist
2 x 4
Vent straight up
through the ceiling
12
Installation Instructions
INSTALLATION – VENTED TO THE OUTSIDE
INSTALL UPPER SUPPORT FRAME
Secure the upper support frame to the ceiling
joists and/or cross framing with the 4 screws
provided. For maximum rigidity and strength, the
screws must be driven into the center of the joists
and/or cross-framing.
Check to be sure the support frame is level,
vertically and horizontally.
INSTALL LOWER SUPPORT FRAME
Insert lower support frame into the upper support
frame and loosely secure with 8 screws and
washers (4 on the front and 4 on the back sides).
Adjust the lower support frame up or down
to the desired height above the countertop.
Tighten screws.
IMPORTANT: Again, check to be sure the support is
level in both directions. There is no way to level the
hood after the hood is secured to the frame.
MOUNT TEMPLATE
Align the template with the marks on the ceiling and
tape in place.
Be sure the template is oriented correctly, with the
front of the hood.
Use a plumb to be sure the mounting holes will provide
parallel alignment with the countertop below.
Center punch all hole locations.
Drill pilot holes in the 4 screw
locations. Use a 5/32 bit and drill
approximately 1-1/2 deep.
Cut wire access hole approximately
1 dia.
Cut the 6-1/2 duct opening
through the ceiling.
13-5/8
24 Minimum
30 Maximum
Wire Access Hole
Front of Hood
13
Installation Instructions
INSTALLATION – VENTED TO THE OUTSIDE
SECURE WIRING
Route house wiring through the ceiling hole and
pull a length to reach the hood junction box.
Tape the wire to the front of the frame support to
prevent damage during installation and service.
Ceiling
Support
Frames
Tape
House
Wiring
Front Side
SIZE AND INSTALL DUCTWORK
Measure from house duct (Dim. A) to bottom of
support frame.
Add at least 1 for duct overlap at the top.
Subtract 3/4 for hood insertion into the bottom
of the frame.
Cut the 6 dia. duct to the required length.
NOTE: The bottom end of the duct must be flared
slightly, to facilitate installation of the hood.
Install duct up through support frames onto the
house duct. Push duct up until it is 3/4 from the
bottom of the support frame flange.
Secure the duct to house duct connection with
screws and seal with duct tape.
Seal duct connection with duct tape, making sure
connection is secured in place.
14
Installation Instructions
INSTALLATION – VENTED TO THE OUTSIDE
INSTALL DECORATIVE DUCT COVERS
Pretap or drive decorative screw into the screw holes
on the support frame. This will make screw installation
easier.
Separate the two decorative duct covers.
Select the inside or top cover with the vent hole
pattern on one end.
For this vented installation to the outside, the hole
pattern should be located at the bottom.
Locate the 2 supplied duct cover screws.
Slide the decorative duct cover over the support frame
and push to the ceiling.
Attach the inside duct cover to the hood support at
the top with 2 supplied duct cover screws.
Locate the stop screw in the hardware bag
.
Install the stop screw into one of the two holes and
tighten against the frame to allow the second duct
cover to slide up and pass over.
Slide the lower duct cover over the installed upper
duct cover and push up past the stop screw location.
Back out the stop screw far enough to support the
bottom duct cover and prevent it from sliding down
onto the top of the hood.
CAUTION: The stop screw must be
installed. Failure to do so could result in personal
injury or damage to the duct cover.
15
CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING: If house wiring is not 2-wire
with a ground wire, a ground must be provided
by the installer. When house wiring is aluminum,
be sure to use U.L.-approved antioxidant compound
and aluminum-to-copper connectors.
Install strain relief onto the knockout of the junction
box cover.
Insert house wiring through strain relief and tighten.
Connect white leads to branch circuit white lead.
Connect black leads to branch circuit black lead.
Connect green/yellow leads to branch circuit green
or bare ground lead.
Secure all connections with wire nuts on each
electrical connector.
Push wires into junction box and replace cover.
Be sure wires are not pinched.
Installation Instructions
INSTALLATION – VENTED TO THE OUTSIDE
7
INSTALL HOOD
NOTE: TWO PEOPLE ARE REQUIRED TO COMPLETE
THIS INSTALLATION!
Lift the hood up to the support frame. Carefully align
the hood mounting studs into the support frame holes,
and at the same time, guide the hood duct connector
into the duct.
Install 4 nuts and lock washers. Tighten with a 10 mm
wrench.
Check hood level in both directions.
Seal the duct connection with duct tape.
NOTE: Do not drive screws through this duct
connection. Doing so will prevent proper damper
operation.
9
SLIDE DUCT COVER DOWN,
INSTALL SIDE UTENSIL RODS
Slide the lower duct cover up and above the
stop screw.
Drive the stop screw in close to the frame.
Slide the lower duct cover down against the top
of the hood. The duct cover should be seated into
the pocket on top of the hood.
Install the side utensil rods with screws as shown.
16

INSTALL FILTERS
Remove protective film on filters.
Tip the filter into the lower channel at the rear
of the opening. Push back, lift and pull the knob
forward until the filter rests on the channel.
Install all three metal grease filters.
Turn power on. If the filter light on the control panel
glows, adjust the right-side filter in the channel to
engage the switch arm.
Lower Filter
Channels

FINALIZE INSTALLATION
Remove the protective film covering the control panel
on the front face of the hood and any other packaging
materials.
Make sure the filters are seated properly when
installed and the filter light is not on.
Be sure fan and lights operate correctly. Refer to
the Owner’s Manual for operating instructions
and the Problem Solver.
Installation Instructions
INSTALLATION – VENTED TO THE OUTSIDE
Lower
filter channel
Installation Instructions
INSTALLATION – RECIRCULATING
INSTALL AIR DEFLECTOR AND
UPPER SUPPORT FRAME
The duct connector is shipped inside the deflector.
Snap the plastic connector out of
the deflector and remove. Turn it
over. From the bottom, snap the
connector over the opening.
Slide the assembled deflector into
the upper support frame and secure
with 4 small screws.
Secure the upper support frame to
the ceiling joists and/or cross framing
with the 4 screws provided. For maximum rigidity
and strength, the screws must be driven into the center
of the joists and/or cross framing.
Check to be sure the support frame is level, vertically
and horizontally.
MOUNT TEMPLATE
Align the template with the marks on the ceiling and
tape in place.
Be sure the template is oriented correctly, with the
front of the hood.
Use a plumb to be sure the mounting
holes will provide parallel alignment
with the countertop below.
Center punch all hole locations.
Drill pilot holes in the 4 screw
locations. Use a 5/32 bit and drill
approximately 1-1/2 deep.
Cut wire access hole approximately
1 dia.
17
NOTE: Be sure plastic
connector is installed
on the bottom of the
deflector as shown.
Wire Access Hole
Front of Hood
18
Installation Instructions
INSTALLATION – RECIRCULATING
SECURE WIRING
Route house wiring through the ceiling hole
and pull a length to reach the hood junction box.
Tape the wire to the front of the frame support to
prevent damage during installation and service.
Ceiling
Support
Frames
Tape
House
Wiring
Front Side
SIZE AND INSTALL DUCTWORK
Measure from top duct connector (Dim. A)
to bottom of support frame.
Subtract 3/4 for hood insertion into the bottom
of the frame.
Cut the 6 dia. duct to the required length.
NOTE: The bottom end of the duct must be flared
slightly, to facilitate installation of the hood.
Install duct up through support frames onto the
duct connector. Push duct up until it is 3/4 from
the bottom of the support frame flange. See
illustration.
Seal duct connection with duct tape, making sure
the connection is secured in place.
INSTALL LOWER SUPPORT FRAME
Insert lower support frame into the upper support
frame and loosely secure with 8 screws and
washers (4 on the front and 4 on the back sides).
Adjust the lower support frame up or down
to the desired height above the countertop.
Tighten screws.
IMPORTANT: Again, check to be sure the support is
level in both directions. There is no way to level the
hood after the hood is secured to the frame.
13-5/8
19
Installation Instructions
INSTALLATION – RECIRCULATING
INSTALL DECORATIVE DUCT COVERS
Pretap or drive decorative screw into the screw holes
on the support frame. This will make screw installation
easier.
Separate the two decorative duct covers.
Select the inside or top cover with the vent hole
pattern on one end.
For this recirculating installation, the hole pattern
should be located at the top.
Locate the 2 supplied duct cover screws.
Slide the decorative duct cover over the support frame
and push to the ceiling.
Attach the inside duct cover to the hood support at
the top with 2 supplied duct cover screws.
Locate the stop screw in the hardware bag
.
Install the stop screw into one of the two holes and
tighten against the frame to allow the second duct
cover to slide up and pass over.
Slide the lower duct cover over the installed upper
duct cover and push up past the stop screw location.
Back out the stop screw far enough to support the
bottom duct cover and prevent it from sliding down
onto the top of the hood.
CAUTION: The stop screw must be
installed. Failure to do so could result in personal
injury or damage to the duct cover.
Installation Instructions
INSTALLATION – RECIRCULATING
CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING: If house wiring is not 2-wire
with a ground wire, a ground must be provided
by the installer. When house wiring is aluminum,
be sure to use U.L.-approved antioxidant compound
and aluminum-to-copper connectors.
Install strain relief onto the knockout of the junction
box cover.
Insert house wiring through strain relief and tighten.
Connect white leads to branch circuit white lead.
Connect black leads to branch circuit black lead.
Connect green/yellow leads to branch circuit green
or bare ground lead.
Secure all connections with wire nuts on each
electrical connector.
Push wires into junction box and replace cover.
Be sure wires are not pinched.
7
INSTALL HOOD
NOTE: Before installing the hood, the metal damper
flaps on top of the hood exhaust outlet may be removed.
Do not remove the duct transition. The damper is not
required for this recirculating operation.
NOTE: TWO PEOPLE ARE REQUIRED TO COMPLETE
THIS INSTALLATION!
Lift the hood up to the support frame. Carefully align
the hood mounting studs into the support frame holes,
and at the same time, guide the hood duct connector
into the duct.
Install 4 nuts and lock washers. Tighten with a 10 mm
wrench.
Check hood level in both directions.
Seal the duct connection with duct tape.
NOTE: Do not drive screws through this duct
connection. Doing so will prevent proper damper
operation (if present).
9
SLIDE DUCT COVER DOWN,
INSTALL SIDE UTENSIL RODS
Slide the lower duct cover up and above the
stop screw.
Drive the stop screw in close to the frame.
Slide the lower duct cover down against the top
of the hood. The duct cover should be seated into
the pocket on top of the hood.
Install the side utensil rods with screws as shown.
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64