Green Creative 24T5HODRIVER/4CH Guide d'installation

Taper
Guide d'installation

Ce manuel convient également à

GREEN CREATIVE - 1200 Bayhill Drive, Suite 220 - San Bruno, CA 94066 - Tel / Fax: (866) 774-5433 - www.greencreative.com - [email protected]
Ref.#: INS114-24T5HODRIVER-130618
WARNING - Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaire electrical systems. Installation should be performed only by a qualified
electrician in accordance with the National Electrical Code and relevant local code.
WARNING - Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings.
WARNING - To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
WARNING - Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when drilling for installation of LED retrofit kit. Check for enclosed wiring and
components.
Disconnect power at the source before installation, inspection or removal. Do not simply switch off fixture.
This item is rated at 120-277V. Installer must determine whether line voltage 120-277V is available at the luminaire before installation.
Not intended for use with emergency exit fixtures or emergency exit lights.
GREEN CREATIVE T5 EXT tubes and drivers are sold separately. This lamp is DC input. Do not operate LED tubes without corresponding compatible driver (refer to
compatibility table below).
Do not use if product is damaged.
Suitable for use with shunted and non shunted lamp holders.
Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
“This luminaire has been modified to operate GREEN CREATIVE T5 EXT LED lamps” shall be marked on the retrofit luminaire where readily visible by the user
during normal maintenance including re-lamping.
Risk of fire or electric shock. Do not open or modify. No user serviceable parts inside.
Installers should not disconnect existing wires from lamp holder terminals to make new connections at lamp holder terminals. Instead installers should cut existing lamp
holder leads away from the lamp holder and make new electrical connections to lamp holder lead wires by employing applicable connectors.
SUITABLE FOR DRY AND DAMP LOCATIONS ONLY.
Complies with Part 15 of FCC. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any
interference received including interference that may cause undesired operation.
SUITABLE FOR “TYPE IC” OR “TYPE NON-IC” LUMINAIRES.
No external weight or mechanical force should be applied to tube or components.
THE RETROFIT ASSEMBLY IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY UL
OR AUTHORITIES HAVING JURISDICTION.
LED TUBE & DRIVER INSTALLATION GUIDE - WARNING
GUIDE D'INSTALLATION – ATTENTION
COMPATIBILITY TABLE
WARNING - Risque d’incendie ou de choc électrique. L’installation de ce kit LED nécéssite la connaissance des systèmes électriques des luminaires. L’installation doit être faite par
un électricien qualifié en accord avec les normes électriques nationales et locales en vigueur.
WARNING - Risque d’incendie ou de choc électrique. Installer uniquement dans des luminaires aux spécificités et dimensions similaires au dessin et/ou photos.
WARNING - Afin d’éviter tout dommage ou abrasion ne pas laisser de câble en contact avec les bords métaliques ou autre endroit abrasif.
WARNING - Risque d’incendie ou de choc électrique. Le câblage du luminaire peut être endomagé pendant le perçage pour l’installation de ce kit de conversion LED. Vérifier les
câblage et composants qui peuvent être enclos.
• Couper l‘alimentation à la source avant l’installation, l‘inspection ou le retrait. Ne pas simplement éteindre l’appareil.
• Ce produit est évalué à 120-277V. L'installateur doit déterminer si la tension de ligne 120-277V est disponible au niveau du luminaire avant l'installation.
• Non destiné à être utilisé avec un luminaire de sortie de secours ou un éclairage de secours.
• Les tubes T5 EXT GREEN CREATIVE et les pilotes sont vendus séparément. Cette lampe est alimentée en courant continuNe pas utiliser de tubes LED sans pilote
compatible correspondant (voir le tableau de compatibilité ci-dessous).
• Ne pas utiliser si le produit est endommagé.
• Convient pour utilisation avec des porte-lampes shuntés et non shuntés.
Ne pas faire ou modifier des trous dans les boîte de câblage ou tout composant électrique pendant l’installation.
“Ce luminaire a été modifié pour fonctionner Les lampes LED T5 EXT GREEN CREATIVE” doit être inscrit sur le luminaire converti de manière à être visible pendant
l’entretien et notamment le changement de lampe.
Risque de choc électrique. Ne pas ouvrir. Aucune pièce ne peut être changée à l’intérieur.
L’installateur ne doit pas déconnecter les câbles existants au niveau des connecteur de la douille. L’installateur doit couper le câble existant à distance des douilles et utiliser des
connecteurs appropriés pour faire une nouvelle connection.
CONVIENT AUX EMPLACEMENTS SECS ET HUMIDES SEULEMENT.
• Conforme à la partie 15 de la FCC. Le fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas causer d'interférences nuisibles et (2) doit accepter
les interférences reçues, y compris les interférences susceptibles de provoquer un fonctionnement indésirable.
CONVIENT AUX LUMINAIRES DE “TYPE IC” OU DE “TYPE NON-IC”.
Aucun poids externe ou force mécanique ne doit être appliqué au tube ou aux composants.
L’INSTALLATION DE CE KIT DE CONVERSION EST ACCEPTÉ COMME UN COMPOSANT DU LUMINAIRE POUR LEQUEL LE CARATÈRE APPROPRIÉ DE LA
COMBINAISON DOIT ÊTRE DETERMINÉ PAR UL OU LES AUTORITÉS COMPÉTENTES AYANT JURISDICTION.
For model #: 22T5HO/4F/xxx/EXT, 24T5HODRIVER/2CH, 24T5HODRIVER/4CH
Where xxx means 824-965 which indicates CRI and color temperature
Pour les produits suivants: 22T5HO/4F/xxx/EXT, 24T5HODRIVER/2CH,
24T5HODRIVER/4CH
Où xxx signifie 824-965 qui correspond au CRI et couleur de température
LED lamp model
24T5HODRIVER/2CH 24T5HODRIVER/4CH
22T5HO/4F/xxx/EXT
1 lamp / 2 lamps 3 lamps / 4 lamps
LED driver model
GREEN CREATIVE - 1200 Bayhill Drive, Suite 220 - San Bruno, CA 94066 - Tel / Fax: (866) 774-5433 - www.greencreative.com - [email protected]
LED TUBE & DRIVER INSTALLATION GUIDE – INSTALLATION STEPS / GUIDE D’INSTALLATION – ETAPES D’INSTALLATION
1) Read all WARNINGS before continuing this section.
2) Make sure POWER IS TURNED OFF at the source to
the location at which you are installing the product.
3) Remove lens, cover and fluorescent tubes.Cut away all
wires connecting the ballast and remove the ballast if
necessary. (fig. 1)
4) Attach the LED driver to the fixture using existing ballast
mounting holes and screws if present. If necessary, use
self-tapping screws to create new holes and mount the LED
driver.
5) Follow wiring diagrams for number of lamps. (fig. 2-9)
6 For 0-10V dimming circuits, connect the incoming grey
and purple wires to the LED driver's grey and purple wires
using wire nuts (not provided). If no 0-10V dimming circuit is
present, cap off the grey and purple wires.
7 Visibly affix the “Modification Sticker” to the fixture and
reinstall housing cover and lens if applicable.
8) Return power back to the source and installation is
complete.
1) Lisez tous les AVERTISSEMENTS avant de continuer
cette section.
2) Assurez-vous que l'alimentation est coupée à la source
à l'endroit où vous installez le produit.
3) Coupez tous les fils reliant le ballast et enlevez le ballast
si nécessaire. (Fig. 1)
4) Fixez le pilote de LED à l'appareil en utilisant les trous et
les vis de montage de ballast existants si présents. Si
nécessaire, utiliser des vis autoperceuses pour créer de
nouveaux trous et installer le pilote LED.
5) Suivre les schémas de câblage pour le nombre de
lampes. (Fig. 2-9)
6) pour les circuits de gradation 0-10V, raccorder les fils gris
et violets entrants aux fils gris et violet du pilote à l'aide de
connecteurs (non fournis). Si aucun circuit de gradation
0-10V n'est présent, fermez les fils gris et violet.
7) Apposez visiblement fermez l"AUTOCOLLANT DE
MODIFICATION" sur le luminaire et réinstallez le couvercle
du boîtier et la lentille, le cas échéant.
8) Remettre le courant à la source et l'installation est
terminée.
Cut all wires connecting ballast.
Fig.1
Ballast
LED
DRIVER
RED (+)
BLACK (L)
WHITE (N)
PURPLE (DIM+)
GREY (DIM-)
BLACK (-)
BLACK (-)
Fig.2 Double-ended Installation
1-Lamp
Fig.3 Double-ended Installation
2-Lamps
LED
DRIVER
RED (+)
BLACK (L)
WHITE (N)
PURPLE (DIM+)
GREY (DIM-)
BLACK (-)
BLACK (-)
Fig.4 Double-ended Installation
3-Lamps
LED
DRIVER
RED (+)
RED (+)
BLACK (L)
WHITE (N)
PURPLE (DIM+)
GREY (DIM-)
BLACK (-)
BLACK (-)
BLACK (-)
BLACK (-)
Fig.5 Double-ended Installation
4-Lamps
LED
DRIVER
RED (+)
RED (+)
BLACK (L)
WHITE (N)
PURPLE (DIM+)
GREY (DIM-)
BLACK (-)
BLACK (-)
BLACK (-)
BLACK (-)
For model #: 22T5HO/4F/xxx/EXT, 24T5HODRIVER/2CH, 24T5HODRIVER/4CH
Where xxx means 824-965 which indicates CRI and color temperature
Pour les produits suivants: 22T5HO/4F/xxx/EXT, 24T5HODRIVER/2CH,
24T5HODRIVER/4CH
Où xxx signifie 824-965 qui correspond au CRI et couleur de température
Not polarity sensitive, lamps can be wired at either end
For shunted & non-shunted lamp holders
Not polarity sensitive, lamps can be wired at either end
For shunted & non-shunted lamp holders
Not polarity sensitive, lamps can be wired at either end
For shunted & non-shunted lamp holders
Not polarity sensitive, lamps can be wired at either end
For shunted & non-shunted lamp holders
GREEN CREATIVE - 1200 Bayhill Drive, Suite 220 - San Bruno, CA 94066 - Tel / Fax: (866) 774-5433 - www.greencreative.com - [email protected]
LED TUBE & DRIVER INSTALLATION GUIDE – INSTALLATION STEPS / GUIDE D’INSTALLATION – ETAPES D’INSTALLATION
LED
DRIVER
RED (+)
BLACK (L)
WHITE (N)
PURPLE (DIM+)
GREY (DIM-)
BLACK (-)
BLACK (-)
Fig.6 Single-ended Installation
1-Lamp
Fig.7 Single-ended Installation
2-Lamps
LED
DRIVER
RED (+)
BLACK (L)
WHITE (N)
PURPLE (DIM+)
GREY (DIM-)
BLACK (-)
BLACK (-)
Fig.8 Single-ended Installation
3-Lamps
LED
DRIVER
RED (+)
RED (+)
BLACK (L)
WHITE (N)
PURPLE (DIM+)
GREY (DIM-)
BLACK (-)
BLACK (-)
BLACK (-)
BLACK (-)
Fig.9 Single-ended Installation
4-Lamps
LED
DRIVER
RED (+)
RED (+)
BLACK (L)
WHITE (N)
PURPLE (DIM+)
GREY (DIM-)
BLACK (-)
BLACK (-)
BLACK (-)
BLACK (-)
For model #: 22T5HO/4F/xxx/EXT, 24T5HODRIVER/2CH, 24T5HODRIVER/4CH
Where xxx means 824-965 which indicates CRI and color temperature
Pour les produits suivants: 22T5HO/4F/xxx/EXT, 24T5HODRIVER/2CH,
24T5HODRIVER/4CH
Où xxx signifie 824-965 qui correspond au CRI et couleur de température
Not polarity sensitive, lamps can be wired at either end
For non-shunted lamp holders only
Not polarity sensitive, lamps can be wired at either end
For non-shunted lamp holders only
Not polarity sensitive, lamps can be wired at either end