Watts 152A-030100 2 Guide d'installation

Taper
Guide d'installation
IS-152A/252A
Series 152A 252A
Self-Contained Process Regulators
Installation Instructions
The maximum pressure adjustment that can be obtained with the spring provided is shown. Initial pres-
sure should not be over 200psi (13.8 bar) for iron bodies Series 152A and up to 300psi (20.7 bar) for
Series 252A.
1. Before installing, be sure pipe ends are reamed and threads are cut to size. Blow out lines to remove
all loose scale and other foreign matter that can damage valve seat.
2. Be sure to always install regulator with the arrows under the diaphragm flange pointing in the direc-
tion of flow.
* Steam safety valve should be installed to provide emergency protection of equipment.
Green rust inhibitor may be visible on 252A pipe threads. Inhibitor does not affect valve perfor-
mance or service life.
IS-152A/252A 1014 EDP# 1915898 © 2010 Watts
USA: 815 Chestnut St., No. Andover, MA 01845-6098; www.watts.com
Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca
A Watts Water Technologies Company
Limited Warranty: Watts Regulator Co. (the “Company”) warrants each product to be free from defects in material and workmanship
under normal usage for a period of one year from the date of original shipment. In the event of such defects within the warranty period,
the Company will, at its option, replace or recondition the product without charge.
THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH
RESPECT TO THE PRODUCT. THE COMPANY MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. THE COMPANY HEREBY
SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach of warranty, and
the Company shall not be responsible for any incidental, special or consequential damages, including without limitation, lost profits or
the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting from labor
charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical, or any
other circumstances over which the Company has no control. This warranty shall be invalidated by any abuse, misuse, misapplication,
improper installation or improper maintenance or alteration of the product.
Some States do not allow limitations on how long an implied warranty lasts, and some States do not allow the exclusion or limitation of
incidental or consequential damages. Therefore the above limitations may not apply to you. This Limited Warranty gives you specific legal
rights, and you may have other rights that vary from State to State. You should consult applicable state laws to determine your rights. SO
FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING
THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO
ONE YEAR FROM THE DATE OF ORIGINAL SHIPMENT.
Garantía limitada: Watts Regulator Co. (en adelante, “la Compañía”) garantiza, por un período de un año a partir de la fecha de embarque
original, que sus productos están libres de defectos en materiales y mano de obra bajo condiciones de uso normal. En caso de que se
encuentren tales defectos dentro del período de garantía, la Compañía reemplazará o reacondicionará, a su elección, el producto sin
costo alguno.
LA GARANTÍA AQUÍ ESTIPULADA SE OTORGA EN FORMA EXPRESA Y ES LA ÚNICA GARANTÍA OTORGADA POR LA COMPAÑÍA
EN RELACIÓN CON EL PRODUCTO. LA COMPAÑÍA NO OTORGA NINGUNA OTRA GARANTÍA, YA SEA EXPRESA O IMPLÍCITA. LA
COMPAÑÍA POR LA PRESENTE RENUNCIA ESPECÍFICAMENTE A TODAS LAS DES GARANTÍAS, EXPRESAS O IMPLÍCITAS,
INCLUYENDO SIN LIMITACIÓN, LAS GARANTÍAS IMPLÍCITAS DE APTITUD PARA LA COMERCIALIZACIÓN E IDONEIDAD PARA UN
PROPÓSITO EN PARTICULAR.
La solución descrita en el primer párrafo de esta garantía constituirá la única y exclusiva solución por incumplimiento de garantía, y la
Compañía no se hará responsable por daños accidentales, especiales o indirectos, incluyendo sin limitación, la pérdida de ganancias
o el costo de reparación o reemplazo de otra propiedad que resulte dañada por el mal funcionamiento de este producto, otros costos
resultantes por mano de obra, retardos, vandalismo, negligencia, obstrucciones ocasionadas por materiales extraños, daños debidos a
condiciones adversas del agua, químicos o cualquier otra circunstancia sobre la cual la Compañía no tenga control. Esta garantía no
tendrá validez en cualquier caso de abuso, uso indebido, aplicación incorrecta, instalación inadecuada, o mantenimiento adecuado o
alteración del producto.
Algunos Estados no permiten limitaciones en la duración de una garantía implícita y algunos Estados no permiten la exclusión o limitación
de daños accidentales o indirectos. Por lo tanto, es posible que las limitaciones anteriores no sean aplicables en su caso. Esta garantía
limitada le da derechos legales específicos; usted podría tener también otros derechos que vaan según el Estado. Usted debe consultar
las leyes estatales aplicables para determinar sus derechos. EN LA MEDIDA EN QUE SEA CONGRUENTE CON LAS LEYES ESTATALES
APLICABLES, CUALQUIER GARANTÍA IMPLÍCITA QUE NO SEA RECHAZADA, INCLUYENDO LAS GARANTÍAS IMPLÍCITAS DE
APTITUD PARA LA COMERCIALIZACIÓN E IDONEIDAD PARA UN PROPÓSITO EN PARTICULAR, SE LIMITA EN SU DURACIÓN A UN
AÑO A PARTIR DE LA FECHA DEL EMBARQUE ORIGINAL.
Garantie limitée : Watts Regulator Co. (la « Société ») garantit que chacun de ses produits est exempt de vice de matériau et de fabrica-
tion dans des conditions normales d’utilisation pour une période d’un an à compter de la date d’expédition d’origine. Dans l’éventualité
de tels vices se manifesteraient pendant la période de garantie, la Société, à sa discrétion, remplacera ou reconditionnera le produit
sans frais.
LA PRÉSENTE GARANTIE EST EXPRESSE ET REPRÉSENTE LA SEULE GARANTIE OFFERTE PAR LA SOCIÉTÉ POUR CE PRODUIT. LA
SOCIÉTÉ N’OFFRE AUCUNE AUTRE GARANTIE, EXPRESSE OU TACITE. PAR LA PRÉSENTE, LA SOCIÉTÉ REJETTE SPÉCIFIQUEMENT
TOUTE AUTRE GARANTIE, EXPRESSE OU TACITE, NOTAMMENT TOUTE GARANTIE TACITE DE QUALITÉ MARCHANDE OU
D’ADAPTATION À UN BUT PARTICULIER.
Le recours décrit dans le premier paragraphe de cette garantie constitue le seul recours à toute violation de la présente garantie. La Société
ne saurait être tenue responsable de tout dommage accessoire, spécial ou indirect, y compris, de façon non limitative : la perte de profits
ou le coût afférent à la réparation ou au remplacement d’autres biens qui seraient endommagés par suite du fonctionnement incorrect
dudit produit ; d’autres coûts résultant de frais de main-d’œuvre, de retards, de vandalisme, de négligence, d’une obstruction causée par
des matériaux étrangers, de dommages causés par une eau impropre, des produits chimiques ou par tout autre événement échappant au
contrôle de la Société. La présente garantie est déclarée nulle et non avenue en cas d’usage abusif ou incorrect, d’application, d’installation
ou d’entretien incorrects ou de modification du produit.
Certains États n’autorisent pas les limitations de durée d’une garantie tacite ou l’exclusion ou la limitation des dommages accessoires ou
indirects. Les limitations susmentionnées peuvent donc ne pas s’appliquer à vous. Cette garantie limitée vous donne des droits spécifiques
et il se peut que vous ayez aussi d’autres droits qui varient d’un État à l’autre. Veuillez vous référer aux lois applicables de l’État pour déter-
miner vos droits en la matière. DANS LA MESURE PERMISE PAR LA LOI APPLICABLE DE L’ÉTAT, TOUTES LES GARANTIES TACITES
NE POUVANT PAS ÊTRE REJETÉES, Y COMPRIS LES GARANTIES TACITES DE QUALITÉ MARCHANDE ET D’ADAPTATION À UN BUT
PARTICULIER, SONT LIMITÉES QUANT À LEUR DURÉE À UN AN À COMPTER DE LA DATE D’EXPÉDITION D’ORIGINE.
By Pass
No. 152A
*
*
No. 152A
Flow
Flow
Installation
The use of a bypass around a regulator permits
maintenance or repairs without shutting down
the line. This is important where the line supplies
vital services requiring continuous supply. During
repairs regulation can be obtained by manual
regulation of the bypass valve.
Multiple valve installations are very practical espe-
cially where there is a wide variation in demand.
Pressure settings can be varied in each so that,
under small demand, only one regulator is operat-
ing; and as load increases, the other valves will
successively pick up the load. For critical uses one
valve could be maintained as a standby for use
when repairs were being made to the other valves
in the group.
To Readjust loosen lock nut on the adjusting screw. To increase the reduced pressure, turn the adjusting
screw clockwise: to decrease the reduced pressure turn adjusting screw counterclockwise. When mak-
ing adjustment in the reduced pressure, always bleed the line to allow the line pressure to adjust to the
regular setting.
To Clean or replace disc or strainer, remove the large hex head bottom plug. Use socket wrench to
remove regulator seat for replacement.
These regulators are provided with a compensating feature so that an adjustment can be
made externally to eliminate any vibration, hum, or chatter conditions which may exist in
the system due to certain operating flow requirements.
The adjustment control on the valve when received is set in the wide
open position. (Screwdriver slot being in the perpendicular posi-
tion).See Fig. #1. Do not adjust unless necessary.
If adjustment is
required, turn adjust-
ment control with
screwdriver in either direction
slowly until vibration or hum stops. Note:
do not over adjust. Adjust only to the point
where vibration or hum stops, not further.
See Fig. #2.
Series 152A, 252A with Compensator Adjustment Control
(Eliminates Vibration, Hum and Chatter Conditions)
Fig. 1 Wide Open
Fig. 2 Adjusted
Adjustment
Control
Flow
IS-152A252A
Para reajustar, afloje la contratuerca del tornillo de ajuste. Para aumentar la presión reducida, haga girar el tornillo
de ajuste hacia la derecha. Para disminuir la presión reducida, haga girar el tornillo de ajuste hacia la izquierda.
Cuando realice ajustes en la presión reducida, siempre purgue la línea para permitir que la presión de la línea se
ajuste a la configuración regular.
Para limpiar, o reemplazar el disco o filtro, quite el tapón de la parte inferior de cabeza hexagonal grande. Use
una llave de cubo para retirar el asiento del regulador para su reemplazo.
Series 152A, 252A con control de ajuste compensador
(elimina las condiciones de vibración, zumbido y traqueteo)
Estos reguladores se proporcionan con un mecanismo de compensación de modo que se puede hacer un ajuste
en forma externa para eliminar cualquier condición de vibración, zumbido o traqueteo que pueda existir en el
sistema debido a ciertos requisitos de flujo de operación.
Cuando se recibe la válvula, el control de ajuste está en la posición totalmente abierta. (La ranura
para el destornillador se encuentra en la posición perpendicular). Vea la figura N.º 1. No lo ajuste
a menos que sea necesario.
Si es necesario hacer un ajuste,
haga girar lentamente
el control de ajuste
con el destornillador
en cualquiera de las
dos direcciones hasta
que la vibración o el
zumbido se detengan. Nota:
no lo ajuste demasiado. Ajuste sólo hasta el
punto en el que la vibración o el zumbido se
detengan y no más. Vea la figura N.º 2.
Series 152A 252A
Reguladores de proceso autocontenidos
Instrucciones de instalación
Se muestra el ajuste máximo de presión que se puede obtener con el resorte proporcionado. La presión inicial
no debe superar 13,8 bar (200 psi) para los cuerpos de hierro de la Serie 152A y hasta 20,7 bar (300 psi) para la
serie 252A.
1. Antes de instalar, asegúrese de que los extremos de la tubería estén escariados y las roscas estén cortadas
al tamaño adecuado. Inyecte aire en las líneas para eliminar todo el sarro suelto y otros materiales extraños
que puedan dañar el asiento de la válvula.
2. Asegúrese de instalar siempre el regulador con las flechas debajo de la brida del diafragma apuntando en la
dirección del flujo.
* Se debe instalar una válvula de seguridad de vapor para proporcionar protección de emergencia para el
equipo.
Es posible que se vea inhibidor de óxido verde en las roscas de la tubería 252A. El inhibidor no afecta el
rendimiento de la válvula ni la vida útil.
Derivación
N.º 152A
*
*
N.º 152A
Flujo
Flujo
Instalación
El uso de una derivación alrededor del regulador permite
realizar las tareas de mantenimiento o las reparaciones
sin cerrar la línea. Esto es importante donde la línea
proporciona servicios vitales que requieren un suministro
continuo. Durante las reparaciones, la regulación se puede
obtener mediante la regulación manual de la válvula de
derivación.
Las instalaciones de varias válvulas son muy prácticas
especialmente cuando hay una amplia variación en la
demanda. Los ajustes de presión se pueden variar en
cada una, por lo que en casos de una demanda pequeña,
sólo funciona un regulador; y a medida que la carga
aumenta, las otras válvulas se harán cargo de la carga
sucesivamente. Para usos críticos, se podría mantener
una válvula de reserva para usarla cuando se están
realizando reparaciones a las demás válvulas del grupo.
Fig. 1 Totalmente
abierto
Fig. 2 Ajustado
Control de
ajuste
Flujo
Séries 152A et 252A
Régulateurs de procédé autonomes
Instructions d’installation
L'ajustement maximal de la pression que l'on peut obtenir avec le ressort fourni est indiqué. La pression initiale ne
devrait pas dépasser 200 lb/po² (13,8 bar) pour les éléments en fer de la série 152A et jusqu'à 300 lb/po² (20,7
bar) pour la série 252A.
1. À l'installation, les extrémités des tuyaux doivent être alésées et les filetages coupés à dimension. Purgez les
lignes de manière à enlever toutes les écailles lâches pouvant endommager le siège de la soupape.
2. Veillez à toujours installer le régulateur avec les flèches sous la collerette de la membrane pointant en
direction du débit.
* La soupape de sûreté de la vapeur doit être installée pour une protection de l'équipement en cas d'urgence.
L'inhibiteur d'oxydation vert doit être visible sur le filetage des tuyaux 252A. L'inhibiteur n'affecte
pas l'efficacité de la soupape ou sa durée de vie utile.
Dispositif de
dérivation
Nº 152A
*
*
Nº 152A
Débit
Débit
Installation
Utiliser un dispositif de dérivation autour d'un régula-
teur permet un entretien et des réparations sans avoir
à fermer la ligne. Ceci a de l'importance lorsque la
ligne approvisionne des services essentiels devant être
alimentés de façon continue. Pendant les réparations,
on peut régler manuellement à l'aide de la soupape
de dérivation.
L'installation de plusieurs soupapes s'avère très pra-
tique, tout particulièrement lorsque la demande est
très variée. Le réglage de la pression peut varier selon
chacune, de façon à ce que, si la demande est faible,
un seul régulateur fonctionne. Et, au fur et à mesure
que la charge augmente, les autres soupapes pren-
dront la relève. Pour les utilisations essentielles, on
peut conserver une soupape en attente pour usage
lors de réparations aux autres soupapes du groupe.
Pour réajuster, desserrez le contre-écrou sur la vis de réglage. Tournez la vis de réglage dans le sens des aiguilles
d’une montre pour augmenter la pression réduite; pour réduire la pression, tournez la vis de réglage dans le sens
contraire. Purgez toujours la ligne lorsque vous ajustez la pression afin de permettre un réglage régulier de sa
pression.
Pour nettoyer, ou remplacer un disque ou une crépine, enlever le bouchon inférieur de la grande tête hexagonale.
Utilisez une clé à douilles pour enlever et remplacer le siège du régulateur.
Séries 152A et 252A avec commande de réglage du
compensateur (élimine les vibrations, les ronflements
et le broutage)
Ces régulateurs viennent avec un compensateur de sorte que l'on peut effectuer un réglage externe pour éliminer
les vibrations, les ronflements ou le broutage présents dans le système en raison de certaines exigences du débit.
Lorsque reçue, la commande de réglage de la soupape est réglée à la position grande ouverte.
(La fente pour le tournevis est en position perpendiculaire). Voir la Fig. n
o
1. N'ajustez pas à moins
que cela s'avère nécessaire.
Si un ajustement s'avère nécessaire, tournez lentement la commande
de réglage avec un tournevis jusqu'à ce que la vibration ou le ronflement
cesse. Remarque :
Évitez un ajustement
excessif. Réglez
seulement jusqu'au
point d'arrêt de la
vibration ou du ronflement,
pas plus loin. Voir la Fig. n
o
2.
Fig. 1 Grand
ouvert
Fig. 2 Ajusté
Commande
de réglage
Débit
  • Page 1 1
  • Page 2 2

Watts 152A-030100 2 Guide d'installation

Taper
Guide d'installation