Miller Coolmate 3 Le manuel du propriétaire

Catégorie
Système de soudage
Taper
Le manuel du propriétaire

Ce manuel convient également à

OWNER’S MANUAL
ENGLISH
© 2010 MILLER Electric Mfg. Co.
OM-628 174 791L
2010−04
CE And Non-CE Models
Coolmate 3
1. Safety Symbol Definitions
DANGER! − Indicates a hazardous situation which, if not
avoided, will result in death or serious injury. The possible
hazards are shown in the adjoining symbols or explained
in the text.
DANGER! − Indique une situation dangereuse qui si on
l’évite pas peut donner la mort ou des blessures graves. Les
dangers possibles sont montrés par les symboles joints ou
sont expliqués dans le texte.
Have only trained and qualified persons install, operate,
or service this unit. Call your distributor if you do not un-
derstand the directions. For WELDING SAFETY and
EMF information, read wire feeder and welding power
source manuals.
L’installation, l’exploitation et l’entretien de cet appareil
doivent être confiés uniquement à des personnes
qualifiées et convenablement formées. S’adresser à un
distributeur si l’on ne comprend pas les directives. Pour
des renseignements ayant trait à la SÉCURITÉ lors du
soudage et aux champs électromagnétiques, consulter
les manuels traitant les dévidoirs et les sources de
courant pour le soudage.
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury. The possible ha-
zards are shown in the adjoining symbols or explained in
the text.
Indique une situation dangereuse qui si on l’évite pas peut
donner la mort ou des blessures graves. Les dangers
possibles sont montrés par les symboles joints ou sont
expliqués dans le texte.
Beware of moving parts.
Attention! Pièces en mouvement.
NOTICE
Indicates statements not related to personal injury.
Indique des déclarations pas en relation avec des blessu-
res personnelles.
Indicates special instructions.
Indique des instructions spécifiques.
Wear safety glasses with side shields.
Porter des lunettes de sécurité avec protections
latérales.
Beware of electric shock from wiring.
Attention! Risque d’électrocution due au contact avec des
fils.
Recycle or dispose of used coolant in an environmentally
safe way.
Recycler ou éliminer tout liquide de refroidissement usé
conformément aux méthodes prescrites pour assurer la
protection de l’environnement.
CALIFORNIA PROPOSITION 65 WARNINGS
Welding or cutting equipment produces fumes or gases which contain chemicals known to the State of California to cause birth defects
and, in some cases, cancer. (California Health & Safety Code Section 25249.5 et seq.)
This product contains chemicals, including lead, known to the state of California to cause cancer, birth defects, or other reproductive
harm. Wash hands after use.
Avertissements issus de la «Proposition 65»
Les équipements de soudage ou de coupe produisent des émanations ou des gaz qui contiennent des agents chimiques réputés selon
l’État de Californie causer des déficiences congénitales et, dans certains cas, le cancer. (Section 25249.5 et suivantes du «California
Health & Safety Code»)
Ce produit contient des agents chimiques, notamment du plomb, réputés selon l’État de Californie causer des cancers, des malforma-
tions congénitales ou d’autres problèmes de procréation. Se laver les mains après utilisation.
2. EMF Information
Electric current flowing through any conductor causes localized elec-
tric and magnetic fields (EMF). Welding current creates an EMF field
around the welding circuit and welding equipment. EMF fields may in-
terfere with some medical implants, e.g. pacemakers. Protective
measures for persons wearing medical implants have to be taken. For
example, access restrictions for passers−by or individual risk assess-
ment for welders. All welders should use the following procedures in
order to minimize exposure to EMF fields from the welding circuit:
1. Keep cables close together by twisting or taping them, or using
a cable cover.
2. Do not place your body between welding cables. Arrange
cables to one side and away from the operator.
3. Do not coil or drape cables around your body.
4. Keep head and trunk as far away from the equipment in the
welding circuit as possible.
5. Connect work clamp to workpiece as close to the weld as
possible.
6. Do not work next to, sit or lean on the welding power source.
7. Do not weld whilst carrying the welding power source or wire
feeder.
About Implanted Medical Devices:
Implanted Medical Device wearers should consult their doctor and the
device manufacturer before performing or going near arc welding,
spot welding, gouging, plasma arc cutting, or induction heating opera-
tions. If cleared by your doctor, then following the above procedures
is recommended.
OM-628 Page 2
3. Important Information Regarding CE Products (Sold Within The EU)
! This equipment shall not be used by the general public as the EMF limits for the general public might be exceeded during welding.
This equipment is built in accordance with EN 60974−1 and is intended to be used only in an occupational environment (where the general public
access is prohibited or regulated in such a way as to be similar to occupational use) by an expert or an instructed person.
Wire feeders and ancillary equipment (such as torches, liquid cooling systems and arc striking and stabilizing devices) as part of the welding
circuit may not be a major contributor to the EMF. See the Owner’s Manuals for all components of the welding circuit for additional EMF exposure
information.
S The EMF assessment on this equipment was conducted at 0.5 meter.
S At a distance of 1 meter the EMF exposure values were less than 20% of the permissible values.
4. Specifications
801 189-A
Recirculating Coolant System For Water-Cooled GTAW Torches And GMAW Guns
Use With Guns/Torches Rated Up To 600 Amperes
IP Rating: 23 − Not Intended For Use In Heavy Rain, Or Near Splashing Water
3 gal (11.4 L) Coolant Tank Capacity;
Maximum Cooling Capacity: 3,820 W (13,000 BTU/hr) @ 4.2 qt/min (4.0 L/min)
IEC Cooling Capacity: 1,420 W (4,840 BTU/hr) @ 1.1 qt/min (1 L/min)
IEC Cooling Capacity States That The Water Inlet Temperature Can Not Exceed 40° C Above Ambient
Temperature At A 1l/ Min Flow Rate.
Dimensions: 23 in. (584 mm) Long, 12 in. (305 mm) Wide, 13-1/4 in. (337 mm) High
Weight: 39 lb (18 kg)
115 Volt Models Use 5.9 Amperes, 50/60 Hertz, Single-Phase Input Power
230 Volt Models Use 3 Amperes, 50/60 Hertz, Single-Phase Input Power
5. Serial Number And Rating Label Location
The serial number and rating information for this product is located on the back panel. Use rating label to determine input power requirements and/or
rated output. For future reference, write serial number in space provided on cover of this manual.
OM-628 Page 3
6. Warning Label Definitions For CE Products
S-180 663
1 2 3 4 5
6
7 8 9
1 Warning! Watch Out! There are
possible hazards as shown by the
symbols.
2 Electric shock from wiring can kill.
3 Disconnect input plug or power before
working on machine.
4 Moving parts, such as fans, can cut
fingers and hands and cause injury.
Keep away from moving parts.
5 Wear safety glasses with side shields.
6 Read the Owner’s Manual before
working on this machine.
7 Read the labels on the welding power
source, wire feeder, or other major
equipment for welding safety
information.
8 Recycle or dispose of used coolant in
an environmentally safe way.
9 Do not remove or paint over (cover)
the label.
4/96
S-178 910
=
043 810 (HF)
043 809 (AL)
100 h. std.
21 3
6
4
7
5
1 Warning! Watch Out! There are
possible hazards as shown by the
symbols.
2 Disconnect input plug or power before
working on machine.
3 Wear safety glasses with side shields.
4 Plugged filter or hoses cause
overheating and damage.
5 Read Owner’s Manual.
6 Check and clean filter every 100
hours; also check condition of hoses.
7 Use Low Conductivity Coolant No. 043
810 for High-Frequency assisted or
Gas Tungsten Arc Welding
applications. Use Aluminum Protecting
Coolant No. 043 809 where coolant
contacts aluminum parts or for Gas
Metal Arc Welding applications or
where High Frequency is not used.
OM-628 Page 4
7. Symbols And Definitions
. Some symbols are found only on CE products.
A
Amperes Alternating Current Voltage Input
Circulating Unit
With Coolant Pump
V
Volts
Water (Coolant) In-
put
Water (Coolant)
Output
Line Connection
Protective Earth
(Ground)
IP
Degree Of
Protection
I
1
Primary Current
Hz
Hertz
On Off
U
1
Primary Voltage Single Phase
8. WEEE Label (For Products Sold Within The EU)
Do not discard product (where ap-
plicable) with general waste.
Reuse or recycle Waste Electrical
and Electronic Equipment (WEEE)
by disposing at a designated collec-
tion facility.
Contact your local recycling office
or your local distributor for further
information.
9. Coolant Chart
Low Conductivity Coolant
No. 043 810**;
Distilled Or Deionized Water
OK Above 32° F (0° C)
Low Conductivity Coolant
No. 043 810**; Or
Aluminum Protecting Coolant
No. 043 809**;
Distilled Or Deionized Water
OK Above 32° F (0° C)
GTAW Or Where
HF* Is Used
GMAW Or Where
HF* Is Not Used
Application
*HF: High Frequency Current
**Coolants 043 810 and 043 809 protect to -37° F (-38°C) and resist algae growth.
Coolant
Aluminum Protecting
Coolant No. 043 809**
Where Coolant Contacts
Aluminum Parts
NOTICE − Use of any coolant other than those listed in the table voids the warranty on any parts
that come in contact with the coolant (pump, radiator, etc.).
OM-628 Page 5
10. GTAW Connections
801 190-B
! Do not move or operate unit where
it could tip.
1 Lift -Eye
If placing cooling unit on welding power
source, slots are provided in bottom of unit
so it fits over lift-eye.
To prevent overheating, make sure cooling
unit is positioned so airflow is not restricted.
NOTICE − If welding power source has a
water valve, do not connect hoses to water
valve. Connect hoses as shown.
2 Coolant Out Hose
3 Coolant In Hose
Fittings have 5/8-18 left-hand threads.
Connect hoses with proper fittings as
shown.
4 TIG Block
Customer supplied for use with some weld-
ing power sources, or use proper connec-
tor supplied with welding power source.
5 Coolant Tank Cap
Use table in Section 9 to select proper cool-
ant, and fill tank. Maintain coolant level at
approximately 1 in (25 mm) below top of fill-
er neck.
6 Flow Indicator
7 Power Switch
Operation:
Turn power switch On. Flow indicator spins
to indicate that at least 0.53 qt/min (0.5
L/min) of coolant is flowing.
1
Tools Needed:
5/8 in.
2
3
5
6
7
4
OM-628 Page 6
11. GMAW Connections
801 191-B
Tools Needed:
5/8 in.
! Do not move or operate unit where
it could tip.
1 Lift -Eye
If placing cooling unit on welding power
source, slots are provided in bottom of unit
so it fits over lift-eye.
To prevent overheating, make sure cooling
unit is positioned so airflow is not restricted.
NOTICE − If welding power source has a
water valve, do not connect hoses to water
valve. Connect hoses as shown.
2 Coolant Out Hose
3 Coolant In Hose
Fittings have 5/8-18 left-hand threads.
Connect hoses with proper fittings as
shown.
4 Coolant Tank Cap
Use table in Section 9 to select proper cool-
ant, and fill tank. Maintain coolant level at
approximately 1 in (25 mm) below top of fill-
er neck.
5 Flow Indicator
6 Power Switch
Operation:
Turn power switch On. Flow indicator spins
to indicate that at least 0.53 qt/min (0.5
L/min) of coolant is flowing.
2
3
4
5
6
1
OM-628 Page 7
12. Routine Maintenance
! Disconnect power
before maintaining.
3 Months
Blow Out Heat
Exchanger Fins
NOTICE − Clean coolant strainer. Severe con-
ditions may require more frequent cleaning
(continuous use, high/low temperatures, dirty
environment, etc.). Failure to properly clean
coolant strainer voids pump warranty.
6 Months
Replace
Cracked
Hoses
Replace
Unreadable
Labels
Change
Coolant (If
Using Water)
12 Months
Change
Coolant (If
Using 043 809
or 043 810
Coolant)
3/8 in.
Tools Needed:
13. Coolant Maintenance
801 195-B / Ref. 801 194
1 Coolant Filter
Unscrew housing to clean filter.
Changing coolant: Drain coolant by
tipping unit forward. Fill with clean
water and run for 10 minutes. Drain
and refill.
. If replacing hoses, use hoses
compatible with ethylene gly-
col, such as Buna-n, Neo-
prene, or Hypalon. NOTE:
Oxy-acetylene hoses are not
compatible with any product
containing ethylene glycol.
1
OM-628 Page 8
14. Troubleshooting
Trouble Remedy
Coolant system does not work. Be sure input power cord is plugged in to energized receptacle.
Check line fuses or circuit breaker, and fuses F1, F2 if applicable, and replace or reset if necessary.
Motor overheated. Unit starts running when motor has cooled.
Have Factory Authorized Service Agent check Power switch S1 and motor Mot.
Decreased or no coolant flow. Add coolant.
Check for clogged hoses or coolant filter. Clean filter or clean / replace hoses if necessary.
Disconnect pump, and check for sheared coupling. Replace coupling if necessary.
135 796-D
Circuit Diagram For 115 And 230 Volt
Circuit Diagram For 230 Volt (CE Models)
187 733
F1
F2
OM-628 Page 9
15. Parts List
801 196-J
*included with item 24
8
7
6
21
22
5
33
*
32
31
30
29
28
27
18
26
11
11
21
25
24
20
11
23
22
20
19
18
17
16
15
14
13
12
11
10
9
4
3
2
1
Figure 15-1. Complete Assembly
Quantity
Description
Part
No.
Dia.
Mkgs.
043 007
Item
No.
115 230
Figure 15-1Complete Assembly.
Model
Volt Vol
t
043 00
8
1 +166 562 WRAPPER 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 192 449 LABEL, warning general precautionary 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 197 361 PUMP COOLANT w/V−BAND, (includes) 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 126 978 FITTING, hose brs barbed M 3/8tbg x 3/8 2 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 134 795 COUPLER, drive pump 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 196 990 FITTING, hose brs barbed 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 089 120 CLAMP, hose .375 − .450 clip 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 196 991 HOSE, nprn brd no 1 x .250ID 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9 MOT 173 264 MOTOR, 1/4hp 230VAC 50/60Hz 1425/1725rpm (230V model) 1. . . . . . . . . . . . . . . . . . . . .
9 MOT 173 263 MOTOR, 1/4hp 115VAC 50/60Hz 1425/1725rpm (115V model) 1. . . . . . . . . . . . . . . .
10 166 570 BLADE, fan 9.000 5wg 38deg .500 bore cw (setscrew included) 1 1. . . . . . . . . . . . . . . . . . . . . . . . .
11 174 044 TUBING, PVC .375 x .625 OD X 18.000 2 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12 *010 323 CLAMP, Hose .250 - .625 Clp Dia. . . . . . . . . . . . . . . . . . .
13 192 454 PANEL, rear 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14 139 042 BUSHING, strain relief .270/.480 id x .804 mtg hol 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15 PLG1 192 458 CABLE, power 11FT 16ga 3c (230V model) 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15 PLG1 192 457 CABLE, power 10ft 16ga (115V model) 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15 PLG1 192 456 CABLE, pwr 10ft (230V CE Models) 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16 196 515 RADIATOR, heat exchanger 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17 168 267 TANK COOLANT 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18 174 043 TUBING, PVC .375 ID x .625 OD x 1.250 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19 166 608 CAP, tank screw-on w/vent 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20 182 994 TUBE, pick-up coolant 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
21 136 369 TUBING, PVC .375 ID x .625 OD x 10.000 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
22 136 731 HOSE, nprn brd No. 1 x .375 ID x 10.50 black 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
23 166 560 RING, ring ext .500 shaft grv x .042thk 2 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
24 166 564 FILTER, in-line 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-628 Page 10
Quantity
Description
Part
No.
Dia.
Mkgs.
043 007
Item
No.
115 230
Figure 15-1Complete Assembly (continued).
Model
Volt Volt
043 008
25 168 254 CLIP, filter mounting 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
F1, F2 011 116 FUSE, mintr gl slo-blo 7A 250V (230V CE Models only) 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
098 376 HOLDER, fuse mintr (230V CE Models only) 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
215 279 INDICATOR, flow (includes) 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
26 HOUSING, flow indicator 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
27 PADDLE, flow indicator 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
28 166 566 O-RING, 1.301 ID x .070CS (may be bought separately) 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
29 LENS, flow indicator 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
30 S1 177 396 SWITCH, rocker DPST 15A 250VAC 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
31 177 399 PANEL, front 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
32 NAMEPLATE, (order by model and serial number) 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
33 166 571 FITTING, coolant barbed 3/8tbg 5/8-18 female 2 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
*Hose clamps (2 per hose) should be ordered for any hose removal or repair.
BE SURE TO PROVIDE MODEL AND SERIAL NUMBER WHEN ORDERING REPLACEMENT PARTS.
DECLARATION OF CONFORMITY
for European Community (CE marked) products.
MILLER Electric Mfg. Co., 1635 Spencer Street, Appleton, WI 54914 U.S.A. declares that the
product(s) identified in this declaration conform to the essential requirements and provisions of
the stated Council Directive(s) and Standard(s).
Product/Apparatus Identification:
Product Stock Number
COOLMATE 3 115V W/CE COMPLIANCE
043007012
COOLMATE 3 230V W/CE COMPLIANCE
043008012
Council Directives:
S 2006/95/EC Low Voltage
S 2004/108/EC Electromagnetic Compatibility
Standards:
S IEC 609741:2005 Arc welding equipment – Part 1: Welding power sources
S IEC 609742:2008 Arc welding equipment – Part 2: Liquid cooling systems
S IEC 6097410:2007 Arc Welding Equipment – Part 10: Electromagnetic compatibility (EMC) requirements
S EN 50445:2008 Product family standard to demonstrate compliance of equipment for resistance welding,
arc welding and allied processes with the basic restrictions related to human exposure to electromagnetic
fields (0 Hz – 300Hz)
US Signatory:
August 31, 2009
__________________________________________________________________________
David A. Werba
Date of Declaration
MANAGER, PRODUCT DESIGN COMPLIANCE
242092B
ORIGINAL INSTRUCTIONS − PRINTED IN USA © 2010 Miller Electric Mfg. Co. 2010−01
Miller Electric Mfg. Co.
An Illinois Tool Works Company
1635 West Spencer Street
Appleton, WI 54914 USA
International Headquarters−USA
USA Phone: 920-735-4505 Auto-Attended
USA & Canada FAX: 920-735-4134
International FAX: 920-735-4125
For International Locations Visit
www.MillerWelds.com
Model Name Serial/Style Number
Purchase Date (Date which equipment was delivered to original customer.)
Distributor
Address
City
State Zip
Please complete and retain with your personal records.
Always provide Model Name and Serial/Style Number.
Contact a DISTRIBUTOR or SERVICE AGENCY near you.
Welding Supplies and Consumables
Options and Accessories
Personal Safety Equipment
Service and Repair
Replacement Parts
Training (Schools, Videos, Books)
Technical Manuals (Servicing Information
and Parts)
Circuit Diagrams
Welding Process Handbooks
Contact the Delivering Carrier to:
For Service
Owner’s Record
File a claim for loss or damage during
shipment.
For assistance in filing or settling claims, contact
your distributor and/or equipment manufacturer’s
Transportation Department.
Contact your Distributor for:
To locate a Distributor or Service Agency visit
www.millerwelds.com or call 1-800-4-A-Miller
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Miller Coolmate 3 Le manuel du propriétaire

Catégorie
Système de soudage
Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues