PAX D190 Guide d'installation

Taper
Guide d'installation
D190 Mobile payment terminal
PAX TECHNOLOGY LIMITED
Installation Manual
1. Contents Checklist
Please check the components after unpacking. If any one of them is missing, or if there is a page
missing from the product manual, etc. Please use original accessories including power adapter,
USB cable and battery, please contact the dealer if you need to change any accessories.
Name
Qty.
D190 Mobile payment terminal
1
AC Power Adapter
1
USB Cable
1
Battery
1
Product Manual
1
2. Installation
SAM/SIM Card
1) Remove the battery cover.
2) Remove the battery.
3) Insert the SAM/SIM card to the corresponding card slot (PS: The default hardware
configuration only support SIM1 slot).
Battery:
Alignment battery tip side to battery tip in terminal and insert.
3. Instructions
1) Power ON/OFF
Power on: Plug in power adapter or insert the battery, Press button for 3 seconds
until the PAX LOGO display on LCD.
Power off: Press button for 3 seconds until the Power off display on the
LCD ,then press ENTER, then the POS terminal is being turned off.
2) IC Card
Put IC card chip side upward, push-in IC card slot and to bottom.
3) Contactless Card
The card read area is above the LCD, Put the card above the LCD.
4) Battery Charge display
Connecting USB port with external adapter can charge the battery. And there are charging
display.
5) Battery Charge style
Please use the original adapter, if you need to charge.
Working Environment Temperature: 0℃~50(32℉~122)
Humidity: 10%93%( non-condense)
PAX TECHNOLOGY LIMITED
Storage Environment Temperature:-20℃~70(-4℉~158)
Humidity.:5%95% (non-condense)
4. Installation and Usage Tips
1) Avoid putting the terminal in direct sunlight, high temperature, moist, or dusty environment.
2) Forbid non-professional to repair the terminal.
3) Before insert the card, please check internal and around of IC card slot. if you found some
suspicious objects , must report to related administrator.
5. Lithium Ion Battery Usage Tips
WARNING:
1Don't use the battery in sunlight or smoke, dust environment.
2Prohibited to strike, squeeze and tread on battery or throw it into the liquid and fire.
3If battery is impressive, deformed, damaged or exothermic seriously, please stop using
immediately and replace it!
4If the continuous working time is only half of new one, the battery life may be end. Please
replace it!
5Must use the specified battery model and charger, otherwise there will be explosion
6Charging time can not exceed 24 hours. If the battery is out of power, please recharge in time.
Avoid damaging the battery in over-charge and over-discharge.
7If be non-use for long time, please recharge the battery per 6 months to avoid shortening its life.
8Suggest to replace it when the battery have been used for 2 years.
9Be sure to follow the instructions to dispose the wasted batteries.
6. Icon shows
Do not throw away, need professional recycling.
Class II Equipment
For indoor use only
Energy Efficiency Marking
AC voltage
DC voltage
The full text of the EU declaration of conformity is available at the following internet address
https://www.pax.com.cn/ProductCE/index.aspx
FCC compliance statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could
void the users authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-- Consult the dealer or an experienced radio/TV technician for help.
FCC SAR statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. End user must follow the specific operating instructions for satisfying RF exposure
compliance. This transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
The portable device is designed to meet the requirements for exposure to radio waves established
by the Federal Communications Commission (USA). These requirements set a SAR limit of 1.6
W/kg averaged over one gram of tissue. The highest SAR value reported under this standard
during product certification for use when properly worn on the body with minimum distance
10mm.
The portable device is designed to meet the requirements for exposure to radio waves established
by the Federal Communications Commission (USA). These requirements set a SAR limit of 4
W/kg averaged over ten gram of tissue. The highest SAR value reported under this standard
during product certification for use when properly worn on the extremity.
ISED compliance statement
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation,
Science and Economic Development Canadas licence-exempt RSS(s). Operation is subject to the
following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired
operation of the device.
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR
d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio
exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :
(1) L’appareil ne doit pas produire de brouillage;
(2) L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
The device for operation in the band 51505250 MHz is only for indoor use to reduce the
potential for harmful interference to co-channel mobile satellite systems;
le dispositif utilisé dans la bande 5150-5250 MHz est servé à une utilisation en intérieur afin de
duire le risque de brouillage préjudiciable aux systèmes mobiles par satellite dans le me
canal;
IC SAR statement
This equipment complies with ISED radiation exposure limits set forth for an uncontrolled
environment. End user must follow the specific operating instructions for satisfying RF exposure
compliance. This transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
The portable device is designed to meet the requirements for exposure to radio waves established
by the ISED. These requirements set a SAR limit of 1.6 W/kg averaged over one gram of tissue.
The highest SAR value reported under this standard during product certification for use when
properly worn on the body with minimum distance 10mm.
The portable device is designed to meet the requirements for exposure to radio waves established
by the ISED. These requirements set a SAR limit of 4W/kg averaged over ten gram of tissue. The
highest SAR value reported under this standard during product certification for use when properly
worn on the extremity.
L'équipement est conforme aux limites d'exposition aux rayonnements spécifiées par l'ised pour
les environnements non contrôs. L'utilisateur final doit se conformer à des instructions
d'exploitation spécifiques afin de respecter la conformité à l'exposition aux radiofréquences. Cet
émetteur ne doit pas être au même endroit ni fonctionner en collaboration avec une autre antenne
ou un autre émetteur.
L'équipement portatif est conçu pour répondre aux exigences d'exposition aux ondes radio
spécifiées par l'ised. Ces exigences fixent la limite moyenne de SAR par gramme de tissu à 1,6 W
/ kg. Lors de la certification du produit, la valeur SAR la plus élevée rapportée conformément à la
présente norme, lorsqu'elle est portée correctement sur un corps ayant une distance minimale de
10 mm.
L'équipement portatif est conçu pour répondre aux exigences d'exposition aux ondes radio
spécifiées par l'ised. Ces exigences limitent le DAS moyen de 10 g de tissu à 4 W / kg. La valeur
SAR la plus élevée rapportée conformément à la présente norme, lorsqu'elle est portée
correctement sur un membre pendant la certification du produit.
P/N: 200312000000360
PAX TECHNOLOGY LIMITED reserves the right to change product technology specifications
without notifying.
PAX TECHNOLOGY LIMITED
Manufacturer: PAX Computer Technology (Shenzhen) Co.,Ltd.
Address: 4/F, No.3 Building, Software Park, Second Central Science-Tech Road, High-Tech
Industrial Park, Shenzhen, Guangdong, P.R.C.
Tel: 0755-86169630 Fax: 0755-86169634
Website: http://www.pax.com.cn
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

PAX D190 Guide d'installation

Taper
Guide d'installation

dans d''autres langues