Snom M500 Quick Installation Guide

Taper
Quick Installation Guide
M500
Multi-cell SIP DECT Base Station
Quick Installation Guide
illustration scale 100%
Taihoon Kim | 09. Apr. 2021 | Revision 3.2AW / M500 Cordless base
2
Important Safety Information
This symbol is to alert you to important operating or servicing instructions
that may appear on the product or in this user’s manual. Always follow
basic safety precautions when using this product to reduce the risk of
injury, fire, or electric shock.
Important Safety Instructions
When using your telephone equipment, basic safety precautions should always be
followed to reduce the risk of fire, electric shock and injury, including the following:
1. This product should be installed by a qualified technician.
2. This product should only be connected to the host equipment and never directly
to the network such as Public Switch Telephone Network (PSTN) or Plain Old
Telephone Services (POTS).
3. Read and understand all instructions.
4. Follow all warnings and instructions marked on the product.
5. Unplug this product from the wall outlet before cleaning. Do not use liquid or
aerosol cleaners. Use a damp cloth for cleaning.
6. Do not use this product near water such as near a bath tub, wash bowl, kitchen
sink, laundry tub or swimming pool, or in a wet basement or shower.
7. Do not place this product on an unstable table, shelf, stand or other unstable
surfaces.
8. Slots and openings in the back or bottom of the base station and handset are
provided for ventilation. To protect them from overheating, these openings must
not be blocked by placing the product on a soft surface such as a bed, sofa or
rug. This product should never be placed near or over a radiator or heat register.
This product should not be placed in any area where proper ventilation is not
provided.
9. This product should be operated only from the type of power source indicated
on the marking label. If you are not sure of the type of power supplied at the
premises, consult your dealer or local power company.
10. Do not allow anything to rest on the power cord. Do not install this product
where the cord may be walked on.
11. Never push objects of any kind into this product through the slots in the base
station or handset because they may touch dangerous voltage points or create a
short circuit. Never spill liquid of any kind on the product.
3
12. To reduce the risk of electric shock, do not disassemble this product, but take it
to an authorized service facility. Opening or removing parts of the base station
or handset other than specified access doors may expose you to dangerous
voltages or other risks. Incorrect reassembling can cause electric shock when
the product is subsequently used.
13. Do not overload wall outlets and extension cords.
14. Unplug this product from the wall outlet and refer servicing to an authorized
service facility under the following conditions:
A. When the power supply cord or plug is damaged or frayed.
B. If liquid has been spilled onto the product.
C. If the product has been exposed to rain or water.
D. If the product does not operate normally by following the operating
instructions. Adjust only those controls that are covered by the
operation instructions. Improper adjustment of other controls may
result in damage and often requires extensive work by an authorized
technician to restore the product to normal operation.
E. If the product has been dropped and the telephone base and/or
handset has been damaged.
F. If the product exhibits a distinct change in performance.
15. Avoid using a telephone (other than cordless) during an electrical storm. There
is a remote risk of electric shock from lightning.
16. Do not use the telephone to report a gas leak in the vicinity of the leak. Under
certain circumstances, a spark may be created when the adapter is plugged into
the power outlet, or when the handset is replaced in its cradle. This is a common
event associated with the closing of any electrical circuit. The user should not
plug the phone into a power outlet, and should not put a charged handset into
the cradle, if the phone is located in an environment containing concentrations
of flammable or flame-supporting gases, unless there is adequate ventilation. A
spark in such an environment could create a fire or explosion. Such environments
might include: medical use of oxygen without adequate ventilation; industrial
gases (cleaning solvents; gasoline vapors; etc.); a leak of natural gas; etc.
17. Only put the handset of your telephone next to your ear when it is in normal talk
mode.
18. The power adapters are intended to be correctly oriented in a vertical or floor
mount position. The prongs are not designed to hold the plug in place if it is
plugged into a ceiling, under-the-table or cabinet outlet.
19. Use only the power cord indicated in this manual.
4
20. For pluggable equipment, the socket-outlet shall be installed near the
equipment and shall be easily accessible.
21. In wall mounting position, make sure to mount the telephone base on the wall
by aligning the eyelets with the mounting studs of the wall plate. Then slide the
telephone base down on both mounting studs until it locks into place. Mount
the device only at heights not exceeding 2 meters. Refer to the full installation
instructions in the User Manual.
22. CAUTION: Keep small metallic objects such as pins and staples away from the
handset receiver.
23. WARNING: The product included (ITE) in this manual is to be connected only to
PoE networks without routing to the outside plant.
SAVE THESE INSTRUCTIONS
Power requirements
Power over Ethernet (PoE): IEEE 802.3af supported, class
3
If PoE not available, power adapter (sold separately):
NBS12E050200UV Input: 100-240V AC 50/60Hz
Output: 5.0V DC @ 2A
For cUL compliance only
Mesures de sécurité importantes
Ce symbole vous alertera d’informations importantes ou d’instructions
d’entretien pouvant apparaître dans ce guide d’utilisation. Respectez
toujours les mesures de sécurité et de sécurité de base lorsque vous
utilisez ce produit, afin de réduire les risques de blessures, d’incendie, ou
d’électrocution.
Mesures de sécurité importantes
Afin de réduire les risques d’incendie, de blessures corporelles ou d’électrocution,
suivez toujours ces mesures préventives de base lorsque vous utilisez votre
téléphone
1. Cet appareil doit être installé par un technicien qualifié.
2. Cet appareil doit être branché à un équipement hôte et jamais branché à un
réseau, tel qu’un réseau PSTN publique ou un réseau téléphonique standard
(POTS).
5
3. Lisez et comprenez bien toutes les instructions.
4. Observez toutes les instructions et mises en garde inscrites sur l’appareil.
5. Débranchez ce téléphone de la prise murale avant de le nettoyer. N’utilisez pas
de nettoyeurs liquides ni en aérosol. N’utilisez qu’un chiffon doux et légèrement
humecté.
6. N’utilisez pas ce produit près de l’eau, tel que près d’un bain, d’un lavabo, d’un
évier de cuisine, d’un bac de lavage ou d’une piscine, ou dans un sous-sol humide
ou sous la douche.
7. Ne déposez pas ce téléphone sur un chariot, support ou table chancelants.
L’appareil pourrait tomber et être sérieusement endommagé.
8. Le boîtier de l’appareil est doté de fentes et d’ouvertures d’aération situées à
l’arrière ou en dessous. Afin d’empêcher la surchauffe, ces ouvertures ne doivent
pas être obstruées en plaçant l’appareil sur un lit, divan, tapis ou autre surface
similaires. Ne placez pas cet appareil à proximité d’un élément de chauffage ni
d’une plinthe électrique. De plus, ne l’installez pas dans une unité murale ou un
cabinet fermé qui ne possède pas d’aération adéquate.
9. Ne faites fonctionner cet appareil qu’avec le type d’alimentation indiqué sur les
étiquettes de l’appareil. Si vous ne connaissez pas le voltage de votre maison,
consultez votre marchand ou votre fournisseur d’électricité.
10. Ne déposez rien sur le cordon d’alimentation. Installez cet appareil dans
un endroit sécuritaire, là où personne ne pourra trébucher sur la ligne
d’alimentation ni le cordon téléphonique modulaire.
11. N’insérez jamais d’objets à travers les fentes et ouvertures de cet appareil, car
ils pourraient toucher à des points de tension dangereux ou court-circuiter des
pièces, ce qui constituerait un risque d’incendie ou d’électrocution. N’échappez
pas de liquides dans l’appareil.
12. Afin de réduire les risques d’électrocution, ne démontez pas l’appareil, mais
apportez-le plutôt à un centre de service qualifié s’il doit être réparé. En
enlevant le couvercle, vous vous exposez à des tensions dangereuses ou
autres dangers similaires. Un remontage inadéquat peut être à l’origine d’une
électrocution lors d’une utilisation ultérieure de l’appareil.
13. Ne surchargez pas les prises de courant ni les rallonges électriques, car ceci
peut constituer un risque d’incendie ou d’électrocution.
14. Débranchez cet appareil de la prise de courant et communiquez avec le
département de service à la clientèle de Snom dans les cas suivants:
A. Lorsque le cordon d’alimentation est endommagé ou écorché.
B. Si du liquide a été échappé dans l’appareil.
6
C. Si l’appareil a été exposé à une source d’humidité telle que la pluie ou l’eau.
D. Si l’appareil ne fonctionne pas normalement en suivant les directives du
guide. N’ajustez que les commandes couvertes dans le guide d’utilisation,
car un mauvais réglage de celles-ci peut être à l’origine de dommages, ce qui
nécessiterait des réparations considérables pour remettre l’appareil à son
état de fonctionnement normal.
E. Si l’appareil a été échappé ou son boîtier, endommagé.
F. Si le produit affiche une nette diminution de sa performance.
15. Évitez d’utiliser un téléphone (autre qu’un sans fil) pendant un orage. Les éclairs
peuvent être à l’origine d’une électrocution.
16. N’utilisez pas le téléphone pour rapporter une fuite de gaz à proximité de
celle-ci. Sous certaines circonstances, une inteincelle pourrait survenir
lorsque l’adaptateur est branché à une prise de courant, ou lorsque le combiné
est déposé sur le combiné. Ceci est un événement commun associé avec
la fermeture d’un circuit électrique. L’utilisateur ne devrait pas brancher le
téléphone dans une prise de courant, et ne devrait pas déposer le combiné
chargé sur le socle, si le téléphone se trouve dans un environnement ou la
concentration de gaz inflammables, sans ventilation adéquate. Une étincelle
dans ces endroits pourrait provoquer un incendie ou une explosion. Ces
environnements pourraient être l’utilisation médicale de l’oxygène sans
ventilation adéquate; le gaz industriel (dissolvants, vapeurs d’essence, etc.);
une fuite de gaz naturel, etc.
17. Placez uniquement le combiné de votre appareil près de votre oreille lorsqu’il
est en mode de conversation normal.
18. Les adaptateurs sont conçus pour être orientés en position verticale ou en
position horizontale sur le plancher.
19. N’utilisez que cordon d’alimentation et les piles indiquées dans ce guide
d’utilisation.
20. Pour les PRODUITS À BRANCHER À UNE PRISE DE COURANT, la prise de courant
doit être installée près du produit, afin d’assurer une accessibilité sécuritaire à la
prise de courant.
21. En position de montage mural, assurez-vous de monter le socle du téléphone
sur le mur en alignant les oeillets avec les goujons de fixation de la plaque
murale. Ensuite, faites glisser le socle vers le bas sur les deux goujons de fixation
jusqu’à ce qu’il se verrouille en place. Ne fixez l’appareil qu’à des hauteurs ne
dépassant pas 2 mètres. Reportez-vous aux instructions complètes dans la
section Installation dans ce guide d’utilisation.
7
22. MISE EN GARDE : Éloignez les petits objets métalliques tels que les broches de
l’écouteur du combiné.
23. AVERTISSEMENT : Le produit inclus (ITE) dans ce guide doit être connec
uniquement aux réseaux PoE sans être acheminé vers l’installation extérieure.
CONSERVEZ CES INSTRUCTIONS
Exigences en matière
d’alimentation
Alimentation par Ethernet (PoE) : IEEE 802.3af suppor,
classe 3
Si PoE non disponible, adaptateur d’alimentation (vendu
séparément) : NBS12E050200UV Entrée : 100-240V AC
50/60Hz
Sortie : 5,0 V CC @ 2 A
8
Compliance
FCC part 15
This device complies with Part 15 of the FCC rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause
undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated
in a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at the user’s expense.
Privacy of communications may not be ensured when using this phone.
Warning: Changes or modifications to this equipment not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
Caution: To maintain the compliance with the FCC’s/ISEDC’s RF exposure guideline,
place the base unit at least 20 cm from nearby persons.
Industry Canada
This Class A digital apparatus complies with Canadian requirements:
CAN ICES-3 (A)/NMB-3(A). Cet appareil numérique de la classe A est conforme à la
norme CAN ICES-3 (A)/NMB-3(A) du Canada.
This device contains licence-exempt transmitter(s)/receiver(s) that comply with
Innovation, Science and Economic Development Canada’s licence-exempt RSS(s).
Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including interference
that may cause undesired operation of the device.
Privacy of communications may not be ensured when using this telephone.
The term ‘’IC:‘’ before the certification/registration number only signifies that the
Industry Canada technical specifications were met.
9
Parts Checklist
Your package contains the following items. Save your sales receipt and
original packaging in the event warranty service is necessary.
About this Guide
This quick installation guide provides a reference for the external features of the
base station and basic installation instructions.
For customer service or product information, visit our website at
www.snomamericas.com .
Ethernet cable
Quick
Installation
Guide
Quick start guide
M500
Base Station
illustration scale 100%
Taihoon Kim | 09. Apr. 2021 | Revision 3.2AW / M500 Cordless base
10
SIP LED
Power LED
LINK button
illustration scale 100%
Taihoon Kim | 09. Apr. 2021 | Revision 3.2AW / M500 Cordless base
LINK LED
Quick Reference Guide
Base station external features - Front view
11
Quick Reference Guide
Base station external features - Rear view
illustration scale 100%
Taihoon Kim | 09. Apr. 2021 | Revision 3.2AW / M500 Cordless base
Holes for
wall mounting
Network and
PoE port
Multicell port
for connecting
another M500
AC adapter input
If no POE available
USB port
Reset button
Press for 15
seconds to restore
factory defaults
12
Status Indicators on the Base Station
LED Color Pattern Description
Power Green Steady • Base station just powered ON and proceeding to IP
retrieval
• Power has been On and IP is assigned to the base
station
• ON for five seconds after the confirmation of system
deregistration
OFF • Base station is not powered up
Slow
flash
• During deskset/handset registration, i.e. subscription
mode
• Power has been On and DHCP has been enabled, but no
IP is assigned to the base station
• Toggles with the SIP LED for negotiating or checking
with provisioning server
Quick
flash
• Ready to deregister deskset/handset
• Toggles with SIP LED for base station/deskset/handset
firmware upgrade or configuration import in progress
SIP LED
Power LED
LINK LED
illustration scale 100%
Taihoon Kim | 09. Apr. 2021 | Revision 3.2AW / M500 Cordless base
13
LED Color Pattern Description
SIP Green Steady • All enabled SIP accounts are registered; displayed on a
Primary or Single cell base station
• ON for five seconds after the confirmation of system
deregistration
Slow
Flash
• During deskset/handset registration, i.e. subscription
mode
• Toggles with the power LED for negotiating or checking
with provisioning server
Quick
Flash
• Ready to deregister deskset/handset
• Toggles with the Power LED for base station/deskset/
handset firmware upgrade or configuration import in
progress
Red Slow
Flash
• At least one enabled SIP account is deregistered;
displayed on a Primary or Single cell base station
Red &
Green
Slow
Flash
• Toggles red and green within the SIP LED for “Primary
base” mode during base selection mode
Orange Steady • All enabled SIP accounts are registered; displayed on a
Secondary base station
Slow
Flash
• At least one enabled SIP account is deregistered;
displayed on a Secondary base station
Status Indicators on the Base Station
14
LED Color Pattern Description
LINK Green Steady • This base station is connected with deskset(s)/
handset(s) and registered base stations (if any)
• ON for five seconds after the confirmation of system
deregistration
Slow
Flash
• During deskset/handset registration, i.e. subscription
mode;
• This base station is connected with registered base
station(s) (if any), but not connected with any
registered deskset/handset at the moment
Quick
Flash
• Ready to deregister deskset/handset
Red Steady • This base station is registered and connected with
other base stations, but the M500 system has no record
of deskset/handset
Slow
Flash
• This base station cannot connected with other
registered base station(s) in the same network,
whether or not the base station is connected to
deskset(s)/handset(s)
Quick
Flash
• This base station cannot find the master base unit; or
the master base unit is down
Red &
Green
Slow
Flash
• Toggles red and green within the LINK LED for
“Secondary base” mode during base selection mode
Orange Slow
Flash
• This Base station is a standalone base unit that is not
registered with any Deskset/handset or base station
Orange
&
Green
Slow
Flash
• Toggles orange and green within the LINK LED for
“Factory reset without reboot” during base selection
mode
Status Indicators on the Base Station
15
Base Station Installation
This section assumes that your network infrastructure is established and that your
IP PBX phone service has been ordered and configured for your location.
You can power the base station using Power over Ethernet (PoE) from your network or
using a power adapter (sold separately). The base station requires PoE Class 3.
If you are not using PoE, install the base station near a power outlet not controlled by a
wall switch. The base station can be placed on a flat surface or mounted on a wall in a
vertical or horizontal orientation.
Avoid placing the base station too close to:
Communication devices such as television sets, DVD players, or other cordless
telephones
Excessive heat sources
Noise sources such as a window with traffic outside, motors, microwave ovens,
refrigerators, or fluorescent lighting
Excessive dust sources such as a workshop or garage
Excessive moisture
Extremely low temperature
Mechanical vibration or shock such as on top of a washing machine or work bench
Note: For cordless accessory installation, see the M55 SIP DECT Handset Quick
Installation Guide or the M58 SIP DECT Deskset Quick Installation Guide.
16
Facility without network infrastructure
Facility with network infrastructure
17
Connecting the base station
The base station can be operated with Power over Ethernet (PoE) provided via the
network cable or, if PoE is not available in your network, with the separately available
5V DC power adapter.
Plug the Ethernet (network) cable into the RJ45 connector labeled “NET”, and plug the
other end into the network side to establish a data link. If PoE is not available, insert
the plug of the power supply into the connector labeled “5V DC” and hook up the plug to
the wall outlet.
The second RJ45 connector, labeled “MULTI-CELL”, is for connecting a second M500
base station (dual cell operation) without the need for a second Ethernet connection
line. In a future M500 release, you can daisy-chain up to five additional M500 base
stations (multi-cell operation).
IMPORTANT INFORMATION
1. Use only a compatible Snom power adapter (model number NBS12E050200UV).
To order a replacement power adapter, visit our website at
www.snomamericas.com .
2. The power adapter is intended to be correctly oriented in a vertical or floor mount
position. The prongs are not designed to hold the plug in place if it is plugged into a
ceiling, under-the-table or cabinet outlet.
18
Setting the base station’s operating mode using the LINK button
You can use the LINK button to set the operating mode of an M500 base station:
Single (default) - for single cell operation
Primary - to act as the Primary base station in dual cell or multi-cell operation
Secondary - to act as a Secondary base station in dual cell or multi-cell operation
To change the base station’s operating mode:
1. Press and hold the LINK button on the base station for at least 20 seconds.
All LEDs turn off.
NOTE: If all three LEDs are flashing green, then you did not hold the LINK key long
enough. Wait five seconds for the three LEDs to stop flashing green, and then try
step 1 again.
2. Press the LINK button (for less than two seconds) to activate the sub-menu.
The SIP or LINK LEDs flash in alternating colors to indicate the currently selected
sub-menu option.
Sub-menu option SIP LED LINK LED
Change operating mode to
Primary
Flashing green/red Off
Change operating mode to
Secondary
Off Flashing green/red
<empty>
Reserved for future use
Flashing orange/red Off
<empty>
Reserved for future use
Off Flashing orange/red
<empty>
Reserved for future use
Flashing orange/green Off
Factory Reset AND change
operating mode to Single
Off Flashing orange/green
3. To move to the next sub-menu option, press the LINK button (for less than two
seconds). Repeat until the desired sub-menu option is indicated by the flashing SIP
or LINK LEDs.
NOTE: If 10 seconds has elapsed without pressing the LINK button, the sub-menu
will time out and the base station LEDs will display their normal status indications.
4. To select the sub-menu option indicated by the flashing SIP or LINK LEDs, press
and hold the LINK button for at least two seconds.
19
5. Wait for the base station to reboot. This takes approximately 70 seconds. During
this time, the LED indications will change.
When the base station has finished rebooting, the LEDs will display their normal
status indications (see “Status Indicators on the Base Station” on page 12).
20
Mounting the base station on a wall
1. Unscrew the foot stand, and remove it from the base station.
2. Install two mounting screws on the wall. Choose screws with heads larger than
5 mm (3/16 inch) in diameter (1 cm / 3/8 inch diameter maximum). The screw
centers should be 60 mm (2 3/8 inches) apart vertically or horizontally. Tighten
screws until only 3 mm (1/8 inch) of the screws are exposed.
3. Connect the Ethernet cable and
power as described in “Base Station
Installation” on page 15-16.
4. Place the base station over the
mounting screws.
Mount the device
only at heights not
exceeding 2 meters.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Snom M500 Quick Installation Guide

Taper
Quick Installation Guide

dans d''autres langues