Serene Innovations CA-360Q Visual Alert System Manuel utilisateur

Taper
Manuel utilisateur
VISUAL ALERT SYSTEM
USER'S MANUAL
MODEL CA-360Q
06:30A 06:30P
pm
1
2
M
EN
Copyright 2020 Serene Group, Inc. All rights reserved. 02.
TABLE OF CONTENTS
CA-360Q Features
Important Safety Instructions
General Description
Package Contents
Unit Overview
Display Details
Display Details Description
Installation
Landline Telephone Connection
Quick Self Test
Voice Announce Language Select
Set the Clock
Set Alarm Time
Direct Connect to an External Lamp Module CA-LX
Reset button
Special Note when running as Remote Receiver
Energy Saving Mode
Adding Extra Wireless Sensor Accessories
CA-AX Special Warning Message
View accessories registered
Set the Date
Ignore Select accessories
Clear All Accessories
System Menu
System Reset
6GEJPKECN5RGEKƒECVKQPU
Accessories for Sereonic Alert
FAQ
Warranty Service Information
FCC & IC Information
03
04
05
06
07
08
09
10
10
11
11
11
11
12
12
12
12
13
13
14
14
14
14
15
17
18
18
19
21
22
EN
03. www.sereneinnovations.com
2.4GHz Wireless Smart-Code Technology
- 360 full coverage of your entire home
Alarm clock
Baby's crying
Doorbell
Motion Sensor
Features:
Advanced Visual alert system alerts you to daily sounds:
Phone / cell
Weather alerts (external alarm)
Audio alarms
SOS paging and more
Loud speaker
Bright flasher
Bed shakers
Visual icons
Alerting accessory
Multiple alerting outputs:
Dual alarm settings (12/24-hr format)
Auto clock-dimming for a softer display at night
Dual bed shaker output jacks
Wireless Smart-Code technology supports thousands
of systems
Internal antenna design for long range operations
Analog phone jacks for landline telephone ringing
Output jack to control a 100 watt max. lamp module (optional)
Use 520 Hz square-wave technology for maximum audio alert
output
Built-in bright flashlight (with brightness control)
2-way SOS (help) paging
Simple installation – just plug and use
Battery back-up ( 4x AA NiMH)
AC adapter 110/240 VAC, 50/60 Hz operation
7 days full function battery back-up
Contemporary design with large 5” color display
User select color for icons and clocks
Intuitive alerting icons
User select show/hide main clock
Multiple language alert announces
Ignore accessories (in master mode Only)
Main power lost warning
Option to detect unregistered CA-AX audio sensors
Lost contact / Low battery warning on registered CA-AX sensors
EN
Copyright 2020 Serene Group, Inc. All rights reserved. 04.
When using the Sereonic Alert Model CA-360Q, in order to reduce the
TKUMQHƒTGGNGEVTKECNUJQEMQTKPLWT[VQRGTUQPUDCUKEUCHGV[RTGECW-
tions should always be followed, including the following:
Read all instructions before using alliance.
Do not mount or place Master-Unit on a small surface.
Metal surfaces can reduce wireless signal transmission.
This product uses rechargeable batteries. Do not use non-
rechargeable batteries as charging of t his type can cause
battery leakage.
Always disconnect phone cord from wall jack before chang-
ing /installing batteries.
To reduce injury risk, close supervision is necessary when
appliance is used near children.
Do not contact moving parts or exposed metal surfaces.
Only use attachments recommended / sold by the manu-
facturer.
Do not use outdoors. Do not use near water.
To disconnect device, remove attached plugs from the
device.
Do not unplug the unit by pulling the cord – grasp plug, not
cord.
Unplug unit from outlet when not in use / before servicing
or cleaning.
Do not operate an appliance with a damaged cord or plug;
do not operate any appliance after it malfunctions, is
dropped or damaged in any manner. Return appliance to
nearest authorized facility for examination; repair or electri-
cal / mechanical adjustment.
Avoid using telephone products during electrical storms.
There's an electrical shock risk from lightning.
Do not use telephone to report a gas leak while in the
vicinity of the leak.
5RGEKƒECVKQPU QH VJKU RTQFWEV CTG UWDLGEV VQ EJCPIG
without notice.
Important Safety Instructions:
01.
02.
03.
04.
05.
06.
07.
08.
09.
10.
11.
12.
13.
14.
15.
EN
05. www.sereneinnovations.com
Model CA-360Q is an advanced wireless visual alert system for the
general public and special geared for the hard-of-hearing (HOH). It
has a dual-alarm clock with a 5 inch (diagonal) color graphics display,
and uses an exclusive Smart-Code technology and operates in the
2.4 GHz band. This technology offers a fast response and long range
operation. It can support thousands of systems without the need for
channel-setting switches.
The system alerts users to multiple different household
HWPEVKQPUGXGPVU WUKPI ƒXG  CNGTVKPI QWVRWVU URGCMGT HNCUJGT
bed-shaker, large visual icons, and digital voice speech. The display
icon shows the name of the alert activation (optional accessories
purchased separately).
&KHHGTGPVU[UVGOEQPƒIWTCVKQPUECPDGUGVWRQPVJG%#36JG
basic system setup can have only one (1) CA-360Q unit as the
master, and multiple remote receivers.
Additional wireless sensors, bed-shakers, and remote receivers may
DGRWTEJCUGFVQEQXGTCNCTIGJQOGQTQHƒEG0GYUGPUQTUOWUVDG
registered to the CA-360Q master-unit before they can be recognized
(See later “Adding Extra Wireless Sensor Accessories” section).
The CA-360Q, with its new system menu, provide the user options to
change some of the visual parameters, such as showing / hiding the
main clock, change clock colors, change icons color, change alerting
tones, and change voice speech language.
General Description:
EN
Copyright 2020 Serene Group, Inc. All rights reserved. 06.
Package Contents:
Base Unit User’s Guide
Batteries AC Adapter Phone Cord
7PRCEMCPFTGOQXGKVGOUHTQOVJGDQZ%QPƒTOCNNKVGOUCTGKPENWF-
ed before disposing of the shipping box.
Items included are:
1 – Sereonic Alert CA360Q
1 – User's Guide
1 – Telephone Cable
1 – AC adapter
* Batteries (user provided)
EN
07. www.sereneinnovations.com
FRONT VIEW
BACK VIEW
Unit Overview:
SPK
SOS/PAIR RESET CLOCK
MODE
EN
Copyright 2020 Serene Group, Inc. All rights reserved. 08.
3
4
2
1
Display Details:
5
8 7 6
10
9
EN
09. www.sereneinnovations.com
Display Detail Description
1Alarm-1 icon and set time.
2Detection of unregistered CA-AX audio transmitter icon
Press SPK+Alarm-2 buttons for 2 seconds to enable/disable.
When this function is disabled, the CA-360Q will only sound
alerts to its registered CA-AX audio transmitters. Default is
Off.
3Alarm-2 icon and set time.
4System mode icon - (M)aster or (S)ub (remote)
5Power and battery status icon
Show low battery status on registered CA-AX (audio sensor)
6Motion detect alerts enabled icon
Press “SPK”+“MODE” buttons for 2 seconds to enable/disable.
When function is disabled, the unit will not sound the alert on
registered CA-MX (motion sensor) is triggered. Default is Off.
7Bed shaker connection icon
The number 1 or 2 shows which bed shaker is connected.
Bed shaker-1 will shake when alarm-1 is on.
Bed shaker-2 will shake when alarm-2 is on.
Both shakers will shake when an accessory alert is received.
8Voice speech enable icon
Press MODE button for 3 seconds to change voice language.
9Speaker volume level – Off – Low – High
Press SPK button once to change the speaker volume
setting.
10 Main clock
Press CLOCK button for 2 seconds to show / hide the clock.
Press Alarm-2 button once to turn on/off the alarm
When turned on, use the (for hour) and (for minutes) to set
the alarm time while it is blinking. The time is set when
blinking stopped.
Press Alarm-1 button once to turn on/off the alarm.
When turned on, use the (for hour) and (for minutes) to set
the alarm time while it is blinking. The time is set when
blinking stopped.
EN
Copyright 2020 Serene Group, Inc. All rights reserved. 10.
Installation:
Install four AA size rechargeable NiMH batteries in battery
compartment at bottom of unit.
Warning: Do not use regular batteries, as charging of this type
can cause batteries to leak and damage to the unit.
01.
Land Line Telephone Connection:
Connect an analog telephone to the PHONE OUT jack on the
back.
Connect a telephone cord to the LINE IN jack on the back of the
unit.
01.
02.
Place a call to the telephone number corresponding to the
connected telephone line.
Verify that all alerting outputs - display icon, flasher, ring tone,
and bed shaker (if connected) - respond correctly while the
telephone is ringing.
Verify that by answering the call (from any telephone), all alerting
outputs will stop.
03.
04.
05.
Plug AC adapter into outlet and connect the plug to the unit.
Connect bed shaker to SHAKER-1 output jack.
Press the SPK button to set the volume (speaker icon).
Verify the “M” indicator is shown. Default is master mode.
02.
03.
04.
05.
Note: The CA-360Q will operate without batteries, but installing
batteries is highly recommended to continue system operations
in case of a power outage.
Telephone
EN
11. www.sereneinnovations.com
Quick Self Test:
Press SOS button once on top of the unit. Verify that alert
outputs (speaker, voice, flasher, shaker and alert icon display)
lasts for about 45 seconds, then stops.
Press RESET button can stop at any time.
Verify that the flasher can be toggled ON and OFF using the
RESET button.
01.
02.
03.
Voice Announce Language Select
01.
02.
03.
Set Alarm Time :
Press Alarm-1 or Alarm-2 button once to enable the alarm.
The alarm icon and time will blink. Use the (for hour) and
(for minute) to change the alarm time if needed. The new alarm
time willbe set when it stops blinking.
When the alarm is on, the unit will sound and the connected
shaker will shake for 45-seconds, then stops for a 5 minute
snooze period.
This snooze pattern will repeat for up to one (1) hour. Press and
hold the RESET button for 2 seconds will stop further snoozes.
01.
02.
03.
Set The Clock:
01.
02.
03.
Note: SHAKER-1 and SHAKER-2 output jack corresponds to Alarm-1
and Alarm-2 individually, but BOTH jacks will be active during alerts.
Press the MODE button for about 3 seconds. The display will
show the available language list with the current language selec-
tion highlighted.
Use the or buttons to scroll and press MODE again to select.
If no voice speech is preferred, select Off from the list. The
speech icon with an “X” will be shown for no voice announce-
ments.
If there are remote receivers in the system, this new selected
language will be updated.
Press the (UP) button for 2 seconds to start.
Use the or buttons to select 12/24 format, then press MODE.
Use the button to change the hour, and the button to change
the minutes. The hours and minutes will continue to scroll when
you press the buttons.
2TGUU/1&'QT4'5'6DWVVQPYJGPƒPKUJGF%NQEMKUUGV
EN
Copyright 2020 Serene Group, Inc. All rights reserved. 12.
During alarm clock , press once will stops alarm sounds and
starts a 5-minute snooze, or press for 2 seconds will stop further
snoozes.
In normal operations, press once will turn the flasher On / Off.
In battery mode, press once will turn display on for 3 seconds.
In menu setting, press once will exit the menu.
During alert alarms, press once will stop it, and reset all receiv-
ers.
Accessory low battery icon and warning message appeared:
press once will clear the message for 12 hours, and if press for
more than 6 seconds, the CA-360Q will temporary ignore the
condition until the next accessory check-in signal is received.
When CA-360Q operates as a remote receiver, it can ONLY paired to
a CA-360Q master unit, and cannot paired any accessories to itself.
While the CA-360Q is in remote receiver mode, some critical system
settings will be passed down from the master unit, and will not be
available to change. For normal operations, the user must perform a
system reset to convert the CA-360Q back to a master mode.
01.
02.
03.
04.
05.
06.
Sereonic Alert CA-360Q can control an external lamp via an optional
external lamp module (Model CA-LX, purchased separately).
User can control the lamp ON/OFF using the RESET button on top of
the unit. The operation of this lamp is synchronized with the flasher.
Connect to an External Lamp (Model CA-LX)
Press the Light Control button (rear) for about 6 seconds. The
display will be turned off and the unit will operate in battery mode
(with ac power attached). Press any button will cancel the mode.
All alerting functions are active during the energy saving mode.
Energy Saving Mode
RESET (Multi Function Button):
Note: The external lamp must be left in the ON position, and the lamp
must be incandescent type using less than 100 watts.
The RESET button behavior under different conditions:
Special Note when CA-360Q running as a Remote Receiver:
EN
13. www.sereneinnovations.com
Adding Extra Wireless Sensor Accessories
to the system:
01.
02.
03.
04.
05.
A new wireless sensor (example: a wireless doorbell) must be
learned (registered) into the CA-360Q unit before it can be recog-
nized.
Press and hold the SOS/PAIR button for 6 seconds until it beeps
and display “LEARN”, and the current accessories list.
Press and hold the new accessory's test button for about 6
seconds until the CA-360Q sounds, displayed the accessory
name , and then added to the accessory list.
While still in the learn mode, repeat step 3 above to learn another
accessory. Press the RESET DWVVQPVQGZKVYJGPƒPKUJGF
Test the new wireless accessory by pressing its test button. If
the CA-360Q sounds the alarms, the learning was successful. If
not, repeat the steps above and learn the accessory again.
Since the CA-AX (audio sensor) is primarily associate with detecting
GOGTIGPE[ UQWPFU GZCORNG ƒTG CNCTOU KV KU KORQTVCPV VJCV VJG
CA-360Q keeps constant monitoring with the registered CA-AX.
When the predetermined period has lapsed without receiving a signal
from the CA-AX, a low-battery icon with the AX number will appear,
and a warning message will be displayed. The message can only be
cleared by the Reset button, and will re-appear in 12-hours if the
alerting status has not been cleared.
Special Warning Message from CA-AX
CA-AX
CA-BX
CA-CX
CA-DB or CA-DX or CA-DXH
CA-MX
CA-NOAA
CA-PX
CA-RX
CA-SOS
Wireless Accessory
10
3
1
4 Any combination
3
1
10
10
4
Max Number Allowed
EN
Copyright 2020 Serene Group, Inc. All rights reserved. 14.
Press the MODE button once will display all the accessories learned
(registered) with the CA360Q for about 5 seconds.
To view accessories registered
To Set The Date:
01.
02.
03.
04.
Ignore Select Accessories
Clear All Accessories
01.
02.
03.
This function only applies to CA-360Q in master mode.
Note: CA-360Q unit will not be alarmed by the ignored accessory,
but other remote receivers will be alerted by the accessory.
Note: This action clears all accessories registered in the CA-360Q unit
ONLY, and will not clear the memory from other remote receivers.
Option 1: (will not reset alarm time)
Press SOS / PAIR button for 6 seconds to enter the LEARN
mode.The display will show all the accessories registered.
Press the SOS/PAIR button 16 times in quick successions
to clear.
When successful, the display will show no accessories.
Press the RESET button to exit.
01.
02.
03.
04.
Option 2: (will reset alarm time to 12:00)
Perform a system reset function, see in the later section.
Press the (Down) button for 2 seconds to start.
Use the or buttons to select Year, then press MODE.
Use the or buttons to select Month, then press MODE.
Use the or buttons to select Day, then press MODE.
Press the CLOCK button once will show the date shortly at any
time.
Press and hold the SOS/PAIR button for 6 seconds until it beeps
and display “LEARN”, and the current accessories list.
Use or buttons to scroll and select the accessory you want
to ignore. Press and hold the SPK+ CLOCK buttons for 2
seconds, and the accessory name will be removed from the list.
Press the RESET DWVVQPVQGZKVYJGPƒPKUJGF
EN
15. www.sereneinnovations.com
SYSTEM MENU
Press SPK + Alarm-1 + buttons for 2 seconds to initiate
1
2
M
General CA-AX Alerts Enable / Disable
Note: Press RESET at any time will exit the menu
Note: The periodic check-in and low battery signals from these
non-registered CA-AX units will not be acknowledged by the
CA-360Q, so no warning messages will be generated.
1
a.
b.
When function is enabled, the unit will sound the alerts when ANY
audio transmitter (CA-AX) that is in range and has been activated.
SYSTEM
MENU
Press or button to scroll and highlight this icon
Press the MODE button to enable / disable the function. An
icon will show on the display when enabled.
EN
Copyright 2020 Serene Group, Inc. All rights reserved. 16.
Icons Color
2
a.
b.
c.
d.
Clock Color
3
a.
b.
c.
d.
Voice Announce Language Select
4
a.
b.
c.
d.
Alert Tone Select
5
a.
b.
c.
d.
Exit Menu
6
a.
b.
Use or button to scroll to this icon. Press MODE once.
Use or button to scroll and highlight the color choice.
Press the MODE DWVVQPQPEGVQEQPƒTO
The display will return back to the menu.
Note: All icons will be changed to the new color, except the alert
icons, low battery icon and the master mode.
Use or button to scroll to this icon. Press MODE once.
Use or button to scroll and highlight the color choice.
Press the MODE DWVVQPVQEQPƒTO
The display will return to the menu.
Use or button to scroll to this icon. Press MODE once.
Use or button to scroll and highlight the choice.
Press the MODE DWVVQPVQEQPƒTO
The display will return to the menu.
Use or button to scroll to this icon. Press MODE once.
Use or button to scroll and highlight the tone. A short
sample of the tone will be played.
Press the MODE DWVVQPVQEQPƒTO
The display will return to the menu.
Use or button to scroll to this icon. Press MODE once.
Exits menu and returns to clock display.
EN
17. www.sereneinnovations.com
Note: Press RESET can cancel at this time.
Note:$VDFRQͧUPDWLRQWKHPDLQFORFNVHSDUDWRUZLOOEHGLIIHUHG
To change the system mode, it must go through a system reset. All
CA-360Q settings and paired accessories will be cleared.
System Reset
System Default on CA-360Q is Master Mode (M).
Check Mark :
“X” icon :
Yes - Go ahead with system reset.
No - Cancel system reset
01.
02.
03.
“MASTER” mode – square shaped
“SUB” (remote) mode – triangle shaped
Press SPK + buttons for 2 seconds to initiate.
#VYQNGXGNEQPƒTOCVKQPKUPGGFGF
The 1st level screen checks if still want to proceed,
Use or buttons to highlight the choice, press MODE to select:
A 2nd screen will appear, select the MAIN or SUB system mode.
Use or button to highlight, and press MODE VQEQPƒTO2TGUU
RESET will select the default selection “MAIN”. (Master)
System reset is complete. All previous accessories are cleared.
EN
Copyright 2020 Serene Group, Inc. All rights reserved. 18.
Technical Specifications:
Accessories for the Sereonic Alert
Technology
Phone Ringing Input
Phone jack type
Bed-shaker output jack
External Lamp Control output jack
Display size
Back-up batteries
AC Adapter output
Operating temperature
Storage temperature
Dimensions
Weight
2.4 GHz Smart-Code
>40 Vrms, 20 to 65 Hz
RJ-11C
9VDC, 150mA
9VDC, 150mA
5 inches diagonal
4 x AA NiMH (~1200mAh)
9VDC, 2000mA
10 to 40 C
-10 to 50 C
168 x 105 x 60 mm
377g (with batteries)
Model
CA-AX
CA-BX
CA-CX
CA-DB
CA-DX
CA-DXH
CA-LX
CA-MX
CA-NOAA
CA-PX
CA-RX
CA-SOS
BS-100
CA-BP
Wireless audio alarm sound monitor
Wireless baby-crying sound monitor
Wireless cellphone ringer/flasher
Wireless doorbell unit
Wireless door knocking sensor
CA-DX with plastic door hanger
External Lamp control module
Wireless motion sensor to detect motion
Wireless NOAA (weather alert) radio output monitor
Wireless personal pager/receiver unit
Wireless remote receiver unit
Wireless personal button for paging help
Bed shaker
A pack of four (4) AA size NiMH rechargeable batteries
Description
EN
19. www.sereneinnovations.com
FAQ:
01. Must I install batteries in CA-360Q?
Ans: Batteries are for power outage back-up. The unit works
with AC adapter and batteries are optional. It is strongly
recommended that you install batteries.
02. What type of batteries does it need?
Ans: Please install rechargeable NiMH batteries only. Use of
regular or non-rechargeable batteries will cause battery
leakage, damage unit, and void the product warranty.
04. Is it alright to place CA-360Q Master unit on a metal surface?
Ans: No! Only place it on a non-metallic surface. A metal
surface attenuates wireless signal transmission and
reduces its operating range.
05. Is the wireless doorbell water-resistant?
Ans: Yes, it is water resistant because it is protected with a
rubber gasket. However, do not submerge in water.
06. How long does the doorbell battery last?
Ans: About 8 to 16 months (depends on how often you used it).
Replace battery when its transmit indicator becomes dim
or if its operation becomes less consistent.
07. How many doorbell units can my CA-360Q system support?
Ans: It can support a total of 4 units in any combination of
doorbell (Model CA-DB), and door knock sensor (Model
CA-DX).
08. How about other accessories?
Ans: Refer to the table in the “Adding Wireless Sensors”.
The system can support up to 10 Remote-Receivers
(CA-RX), 10 Personal pagers (CA-PX), 10 audio sensors
(CA-AX), 4 SOS pendants (CA-SOS), 3 Baby-Sound sensors
(CA-BX), 1 Cell-phone sensor (CA-CX), and 1 NOAA sensor
(CA-NOAA)
03. What is the battery back-up time on CA-360Q ?
Ans: About 7 days (normal operation, infrequent alerts)
EN
Copyright 2020 Serene Group, Inc. All rights reserved. 20.
09.
Ans: All new accessory devices must be learned or registered
by a CA-360Q master-unit before they can be worked or
recognized.
I just bought an extra doorbell for my CA-360Q system, but it did
not work. What do I need to do?
13.
Ans: /CMGUWTGVJG%#3KUKPRCKTKPIOQFGƒTUVCPF[QW
press the test button on the accessory for at least 6
seconds when registering, until you hear CA-360Q sounds
CPFFKURNC[VJGEQPƒTOCVKQP
+ JCXG FKHƒEWNV[ KP TGIKUVGTKPI CP CEEGUUQT[ VQ O[ %#3
system. What should I do?
14.
Ans: Yes, CA-360Q and remote receivers has built-in repeater
functions. Each unit can relay the signal it received to the
next unit. This greatly increases effective coverage area.
I have a large home, can I use two or more CA-360Q to increase
coverage area?
10.
Ans: Yes you can. You need to convert three of the CA-360Q
units from “Master” Unit into a “Remote-Receiver” so they
can be learned (or registered) into the “Master” Unit.
I bought four CA-360Q systems for my home. Can I combine
them into a single system?
11. How do I reset accessory's low battery icon on CA-360Q?
Ans: Press the RESET button for 6 seconds. This is only tempo-
rary. The low battery icon will appear again when the next
accessory low battery signal is received.
12. What caused this accessory's low battery icon to show?
Ans: This message is associated with registered sensor's
battery is either low, or not being turned on, or it may be
placed too far from CA-360Q. Turn on its power on move
the sensor closer to CA-360Q usually solve the issue.
15. Why is my CA-360Q displays “AX-0” ?
Ans: Your CA-360Q has enabled the “General CA-AX alerts”
function. It has detected a nearby CA-AX sensor signal not
part of its own. Refer to earlier section on general CA-AX
alerts.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54

Serene Innovations CA-360Q Visual Alert System Manuel utilisateur

Taper
Manuel utilisateur