20 English
Installation instructions
Installation instructions
WARNING
If the information in this manual is not followed exactly, a re or explosion may
result, causing death, personal injury, or property damage.
• Do not store or use gasoline or other ammable vapors and liquids in the vicinity
of this or any other appliance.
• WHAT TO DO IF YOU SMELL GAS:
– DO NOT light a match, candle, or cigarette.
– DO NOT try to light any appliance.
– DO NOT touch any electrical switch.
– DO NOT use any phone in your building.
– Clear the room, building, or area of all occupants.
– Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
– If you cannot reach your gas supplier, call the re department.
• Installation and service must be performed by a qualied installer,
service agency, or gas supplier.
Never use an old connector when installing a new range. If the hard-piping method
is used, you must carefully align the pipe; the range cannot be moved after the
connection is made.
To prevent gas leaks, apply pipe joint compound.
WARNING
Do not wrap pipe thread with Teon tape around which may crack the pressure
regulator.
1. Install a manual gas line shut-off valve in the gas line in an easily accessed
location outside of the range.
Make sure everyone operating the range knows where and how to shut off the
gas supply to the range.
2. Install male 0.5 in (1.3 mm) are union adapter to the 0.5 in (1.3 mm) NPT
internal thread at the regulator inlet. Use a backup wrench on the regulator
tting to avoid damage.
When installing the range from the front, remove the 90° elbow for easier
installation.
3. Install male 0.5 in (1.3 mm) or 0.75 in (1.9 mm) are union adapter to the NPT
internal thread of the manual shut-off valve, taking care to back up the shut-off
valve to keep it from turning.
4. Connect exible metal appliance connector to the adapter on the range.
Position range to permit connection at the shut-off valve.
5. When all connections have been made, make sure all range controls are in the
off position and turn on the main gas supply valve. Use a liquid leak detector at
all joints and connections to check for leaks in the system.
WARNING
To prevent death, personal injury, explosion, and/or re hazard, DO NOT use a
ame to check for gas leaks.
When using test pressures greater than ½ psig to pressure-test the gas supply
system of the residence, disconnect the range and individual shut-off valve from
the gas supply piping. When using test pressures of ½ psig or less to test the gas
supply system, simply isolate the range from the gas supply system by closing the
individual shut-off valve.
WARNING
Do not exceed 25 ft-lbs of torque when making gas line connections.
Overtightening may crack the pressure regulator resulting in a gas leak.
Flexible connector hookup
Installer: Inform the consumer of the location of the gas shut-off valve.
Adapter
Flex
Connector
(6 ft max.)
Adapter
Gas Shut-Off Valve
0.5 in or 0.75 in
Gas Pipe
Tubing Line to
Oven Burner
Control Valve
Gas Flow into Range
Pressure
Regulator
Tubing Line
to Cooktop
Control
Manifold
NOTE
If your area requires a rigid pipe hookup,
contact a qualied installer, service agency,
or gas supplier.
NOTE
The gas shut-off valve should be installed
in an accessible location in the gas piping,
external to the appliance, for the purpose
of turning on or shutting off the gas to the
appliance.
DG68-01600A-00_IM_NSG6DG8700SRAA_EN+MES+CFR.indb 20DG68-01600A-00_IM_NSG6DG8700SRAA_EN+MES+CFR.indb 20 2023-12-20 오후 2:54:202023-12-20 오후 2:54:20