Simplicity 076062-00 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur

Ce manuel convient également à

GE Generator Systems
Liquid-Cooled
Generator System
Operator’s Manual
NOT
FOR REPRODUCTION
2
Thank you for purchasing this quality-built GE standby generator. We’re pleased that you’ve placed your confidence in
the GE brand. When operated and maintained according to the instructions in this manual, your generator will provide
many years of dependable service.
This manual contains safety information to make you aware of the hazards and risks associated with standby
generators and how to avoid them. Because we do not necessarily know all the applications this equipment could
be used for, it is important that you read and understand these instructions thoroughly before attempting to start or
operate this equipment. Save these instructions for future reference.
This generator requires professional installation before use. Refer to the separate installation manual for full
information. Your installer should follow the instructions completely.
Where to Find Us
You never have to look far to find GE support and service for your generator. For quick service when you need it, keep
your original receipt with this manual. You may contact Customer Service at 888 575-8226 between 8:00 AM and
5:00 PM CT, or click on Find a Dealer at BRIGGSandSTRATTON.COM, which provides a list of authorized dealers.
Generator and engine model and serial numbers should be recorded in the installation manual.
NOT
FOR REPRODUCTION
3
Table of Contents
Safety Rules..........................................................4
Installation ..........................................................7
For the Owner ..............................................................7
For the Installing Dealer/Contractor .........................................7
Owner Orientation ..........................................................8
Fuel Factors ................................................................8
Generator Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Delivery Inspection .........................................................9
Controls ...................................................................10
Operation...........................................................13
Automatic Operation.......................................................13
Setting Exercise Timer .....................................................14
Maintenance ........................................................15
Fault Detection System ....................................................15
Generator Maintenance....................................................17
Engine Oil .................................................................17
Synthetic Oils ..............................................................17
Oil Recommendation.......................................................18
Checking Engine Oil Level ..................................................18
Engine V-Belts .............................................................20
Engine Coolant System ....................................................20
Engine Air Cleaner .........................................................21
Generator Electrical System Maintenance ..................................21
Battery ....................................................................22
Fuel System Inspection and Maintenance...................................23
Storage ...................................................................24
Troubleshooting .....................................................26
Warranty ...........................................................28
Product Specifications ...............................................30
NOT
FOR REPRODUCTION
4
Safety Rules
SAVE THESE INSTRUCTIONS - This manual contains
important instructions that should be followed during
installation and maintenance of the generator and batteries.
Safety Symbols and Meanings
The safety alert symbol indicates a potential personal
injury hazard. A signal word (DANGER, WARNING, or
CAUTION) is used with the alert symbol to designate a degree
or level of hazard seriousness. A safety symbol may be used
to represent the type of hazard. The signal word NOTICE is
used to address practices not related to personal injury.
DANGER indicates a hazard which, if not avoided, will
result in death or serious injury.
WARNING indicates a hazard which, if not avoided, could
result in death or serious injury.
CAUTION indicates a hazard which, if not avoided, could
result in minor or moderate injury.
NOTICE addresses practices not related to personal injury.
Important Safety Instructions
The manufacturer cannot possibly anticipate every possible
circumstance that might involve a hazard. The warnings
in this manual, and the tags and decals affixed to the unit
are, therefore, not all-inclusive. If you use a procedure, work
method or operating technique that the manufacturer does
not specifically recommend, you must satisfy yourself that it
is safe for you and others. You must also make sure that the
procedure, work method or operating technique that you
choose does not render the generator system unsafe.
Fire
Toxic Fumes
Explosive Pressure
Rotating Fan Blade
Lift Hazard Read Manual
Exploding BatteryRotating Belt/Pulley
Chemical BurnAuto Start
Hot SurfaceRotating Parts
Electrical ShockExplosion
WARNING The engine exhaust from this product contains
chemicals known to the State of California to cause cancer, birth
defects, or other reproductive harm.
WARNING Certain components in this product and related
accessories contain chemicals known to the State of California
to cause cancer, birth defects, or other reproductive harm. Wash
hands after handling.
WARNING Running engine gives off carbon monoxide, an
odorless, colorless, poison gas.
Breathing carbon monoxide could result in death, serious
injury, headache, fatigue, dizziness, vomiting, confusion,
seizures, nausea or fainting.
• Operate this product ONLY outdoors in an area that will not
accumulate deadly exhaust gas.
• Keep exhaust gas away from any windows, doors, ventailation
intakes, soffit vents, crawl spaces, open garage doors or other
openings that can allow exhaust gas to enter inside or be drawn
into a potentially occupied building or structure.
• Carbon monoxide detector(s) MUST be installed and maintained
indoors according to the manufacturer’s instructions/
recommendations. Smoke alarms cannot detect carbon
monoxide gas.
NOT
FOR REPRODUCTION
5
WARNING Storage batteries give off explosive hydrogen gas
during recharging.
Slightest spark will ignite hydrogen and
cause explosion, resulting in death, serious
injury and/or property damage.
Battery electrolyte fluid contains acid and is extremely caustic.
Contact with battery contents could cause severe chemical burns.
A battery presents a risk of electrical shock and high short
circuit current.
• DO NOT dispose of battery in a fire. Recycle battery.
• DO NOT allow any open flame, spark, heat, or lit cigarette during
and for several minutes after charging a battery.
• DO NOT open or mutilate the battery.
• Wear protective goggles, rubber apron, rubber boots and
rubber gloves.
• Remove watches, rings, or other metal objects.
• Use tools having insulated handles.
WARNING Propane and Natural Gas are extremely flammable
and explosive, which could cause burns, fire or
explosion resulting in death, serious injury and/or
property damage.
• Install the fuel supply system according to NFPA 37 and other
applicable fuel-gas codes.
• Before placing the generator into service, the fuel system lines
must be properly purged and leak tested.
• After the generator is installed, you should inspect the fuel
system periodically.
• NO leakage is permitted.
• DO NOT operate engine if smell of fuel is present or other
explosive conditions exist.
• DO NOT smoke around the generator. Wipe up any oil spills
immediately. Ensure that no combustible materials are left in the
generator compartment. Keep the area near the generator clean
and free of debris.
WARNING Generator produces hazardous voltage.
Failure to properly ground generator could result
in electrocution.
Failure to isolate generator from utility power could result
in death or serious injury to electric utility workers due to
backfeed of electrical energy.
• DO NOT touch bare wires or bare receptacles.
• DO NOT use generator with electrical cords which are worn,
frayed, bare or otherwise damaged.
• DO NOT handle generator or electrical cords while standing in
water, while barefoot, or while hands or feet are wet.
• If you must work around a unit while it is operating, stand on an
insulated dry surface to reduce the risk of a shock hazard.
• DO NOT allow unqualified persons or children to operate or
service generator.
• In case of an accident caused by electrical shock, immediately
shut down the source of electrical power and contact the local
authorities. Avoid direct contact with the victim.
• Despite the safe design of the generator, operating this
equipment imprudently, neglecting its maintenance or being
careless could cause possible injury or death.
• Remain alert at all times while working on this equipment.
Never work on the equipment when you are physically or
mentally fatigued.
• Before performing any maintenance on the generator, disconnect
the battery cable indicated by a NEGATIVE, NEG or (-) first. When
finished, reconnect that cable last.
• After your system is installed, the generator may crank and start
without warning any time there is a power failure. To prevent
possible injury, always set the generator’s system switch to OFF,
remove the service disconnect from the disconnect box AND
remove the 15 Amp fuse BEFORE working on the equipment.
NOT
FOR REPRODUCTION
6
WARNING Moving parts could crush and cut.
Starter and other rotating parts
could entangle hands, hair, clothing,
or accessories resulting in serious injury.
• NEVER operate generator without protective housings, covers, or
guards in place.
• DO NOT wear loose clothing, jewelry or anything that could be
caught in the starter or other rotating parts.
• Tie up long hair and remove jewelry.
• Before servicing, remove 15 Amp fuse from control panel and
disconnect Negative (NEG or -) battery cable.
WARNING Hot pressurized coolant could cause serious injury
and/or property damage.
• DO NOT open radiator cap when hot.
• Before servicing, allow coolant to cool.
CAUTION Installing the 15A fuse could cause the engine
to start at any time without warning resulting in minor or
moderate injury.
• Observe that the 15 Amp fuse has been removed from the control
panel for shipping.
• DO NOT install this fuse until all plumbing and wiring has been
completed and inspected.
CAUTION Excessively high operating speeds could result in
minor injury and/or equipment damage.
Excessively low speeds impose a heavy load on generator.
• DO NOT tamper with governed speed. Generator supplies correct
rated frequency and voltage when running at governed speed.
• DO NOT modify generator in any way.
NOTICE Exceeding generators wattage/amperage capacity could
damage generator and/or electrical devices connected to it.
• Start generator and let engine stabilize before connecting
electrical loads.
NOTICE Improper treatment of generator could damage it and
shorten its life.
• Use generator only for intended uses.
• If you have questions about intended use, contact your
authorized dealer.
• Operate generator only on level surfaces.
• Adequate, unobstructed flow of cooling and ventilating air is
critical to correct generator operation.
• The access panels/door must be installed whenever the unit
is running.
• DO NOT expose generator to excessive moisture, dust, dirt, or
corrosive vapors.
• Remain alert at all times while working on this equipment.
Never work on the equipment when you are physically or
mentally fatigued.
• DO NOT start engine with air cleaner or air cleaner cover removed.
• DO NOT insert any objects through cooling slots.
• DO NOT use the generator or any of its parts as a step. Stepping
on the unit could cause stress and break parts. This may result in
dangerous operating conditions from leaking exhaust gases, fuel
leakage, oil leakage, etc.
• If connected devices overheat, turn them off and disconnect them
from generator.
• Shut off generator if:
-electrical output is lost;
-equipment sparks, smokes, or emits flames;
-unit vibrates excessively.
-unit makes unusual noises.
WARNING Exhaust heat/gases could ignite combustibles or
structures resulting in death, serious injury and/or
property damage.
Contact with muffler area could cause burns
resulting in serious injury.
• DO NOT touch hot parts and AVOID hot
exhaust gases.
• Allow equipment to cool before touching.
• Exhaust outlet side of weatherproof enclosure must have at least
5 ft. (1.5m) minimum clearance from any structure, shrubs, trees
or any kind of vegetation.
• Standby generator weatherproof enclosure must be at least
5 ft. (1.5m) from windows, doors, any wall opening, shrubs or
vegetation over 12 inches (30.5 cm) in height.
• Standby generator weatherproof enclosure must have a minimum
of 5 ft. (1.5 m) overhead clearance from any structure, overhang,
or trees.
• DO NOT place weatherproof enclosure under a deck or other type
of structure that may confine airflow.
• Use only flexible fuel line provided. Connect provided fuel line to
generator. DO NOT use with or substitute any other flexible
fuel line.
• Smoke detector(s) MUST be installed and maintained indoors
according to the manufacturer’s instructions/recommendations.
Carbon monoxide alarms cannot detect smoke.
• Keep at least minimum distances shown in General Location
Guidelines to insure for proper generator cooling and
maintenance clearances.
• Replacement parts must be the same and installed in the same
position as the original parts.
NOT
FOR REPRODUCTION
7
To help you make informed choices and communicate
effectively with your installation contractor(s),
Read and understand Owner Orientation in this manual
before contracting or starting your generator installation.
To arrange for proper installation, contact the store at
which you purchased your generator, your dealer, a licensed
electrician or your utility power provider.
The generator warranty is VOID unless the system is
installed by licensed electrical and plumbing professionals.
Every effort has been made to ensure that information in this
manual is accurate and current. However, we reserve the
right to change, alter, or otherwise improve the product and
this document at any time without prior notice.
The Emission Control System for this generator is warranted
for standards set by the U.S. Environmental Protection
Agency and by the California Air Resources Board (CARB).
For the Owner
If you need more information in this matter, please call
888 575‑8226 between 8:00 AM and 5:00 PM CT..
For most applications, the Installation manual contains
all the information required to properly install and start
the generator. This Operator’s Manual describes routine
operation and owner maintenance procedures.
For the Installing Dealer/Contractor
Installation
We sincerely appreciate your patronage. For this reason, we
have made every effort to provide for a safe, streamlined
and cost-effective installation. Because each installation is
unique, it is impossible to know of and advise the trade of all
conceivable procedures and methods by which installation
might be achieved. Neither could we know of possible
hazards and/or the results of each method or procedure. For
these reasons,
Only current licensed electrical and plumbing
professionals should attempt generator system
installations. Installations must strictly comply with all
applicable codes, industry standards and regulations.
Your generator is supplied with this “Operator’s Manual”
and a separate “Installation Manual”. These are important
documents and should be retained by the owner after the
installation has been completed.
NOT
FOR REPRODUCTION
8
Power Decrease at High Altitude or
High Temperature
Air density is less at high altitudes, resulting in less available
engine power. Specifically, engine power will decrease 3.5%
for each 1,000 feet (300 meters) above sea level and 1%
for each 10° F (5.6°C) above 77°F (25°C). Make sure you and
your installer consider these factors when determining total
generator load.
An important consideration affecting the entire installation
is the type of fuel used by your generator. The system was
factory tested and adjusted using either natural gas or
liquid propane (LP vapor). For proper engine function, factors
that are inherent to each of these fuels, your location and
the duration of possible utility interruptions are important
considerations in the following fuel guidelines:
• Useclean,dryfuel,freeofmoistureorany
particulate material. Using fuels outside the
following recommended values may cause
performance problems.
• Inenginessetuptorunonpropane(LP),commercial
grade HD5 propane with a minimum fuel energy of
2500 BTUs/ft
3
with maximum propylene content of
5% and butane and heavier gas content of 2.5% and
minimum propane content of 90%.
Natural gas rating will depend on specific fuel but typical
derates are between 10 to 20% off the LP gas rating.
Fuel Factors
gaseous fuel supply increases, and the number of 90 degree
bends in the fuel supply increases; compensations in piping
and wiring materials must be made. This is necessary to
comply with local codes and overcome electrical voltage
drops and gaseous fuel pressure drops.
The factors mentioned above will have a direct affect on
the overall price of your generator installation.
In some areas you may need to acquire electrical permits
for installing the generator, building permits for installing
gas lines, and permits for noise allowances. Your installer
should check your local codes AND obtain the permits before
installing the system.
This section provides generator owners with the information
necessary to achieve the most satisfactory and cost effective
installation possible.
The illustrations are for typical circumstances and are meant
to familiarize you with the installation options available
with your generator. A thorough understanding of these
options will provide fundamental control over the cost of
your installation, as well as ensure your final satisfaction
and security.
Federal and local codes, appearance, noise levels, fuel types,
and distances are the factors that must be considered when
negotiating with an installation professional. Remember
that as the distance from the existing electrical service and
Owner Orientation
WARNING Propane and Natural Gas are extremely flammable
and explosive, which could cause burns, fire or
explosion resulting in death, serious injury and/or
property damage.
• The generator is equipped with an automatic safety gas “fuel
shut-off” valve.
• DO NOT operate the equipment if the “fuel shut-off” valve is
missing or inoperative.
NOT
FOR REPRODUCTION
9
The actual physical location of your generator has a direct
affect on:
1. The amount of plumbing required to fuel
your generator.
2. The amount of wiring required to control and connect
your generator.
Specific location guidelines are discussed in the installation
manual. Acquaint yourself with that information and confer
with your installer. Be sure to ask how your site might
affect installation costs and compliance with local codes
and standards.
The generator must be installed outdoors. DO NOT install
generator where exhaust gas could accumulate and enter
inside or be drawn into a potentially occupied building.
Ensure exhaust gas is kept away from any windows, doors,
ventilation intakes or other openings that can allow exhaust
gas to collect in a confined area. Prevailing winds and air
currents should be taken into consideration when positioning
generator. See the installation manual for full details on safe
generator location.
Generator Location
Delivery Inspection
Carefully inspect the generator for any damage that may
have occurred during shipment.
If loss or damage is noted at time of delivery, have the
person(s) making delivery note all damage on the freight bill
and affix his signature under the consignor’s memo of loss or
damage. If loss or damage is noted after delivery, separate
the damaged materials and contact the carrier and your
installer for claim procedures. Missing or damaged parts are
not warranted.
The generator system is supplied with:
• Fully-servicedcoolantsystem
• Fully-servicedoil/lubricatingsystem
• Flexiblefuelhook-up
• Installationandstart-upmanual
• Operator’smanual
• Spareaccessdoorkeys
• Spare15AmpATO-typefuse
• Ten-pincontrolpanelconnector
• Touchuppaint
• RemoteLEDindicatorkit(LED/plate/screws)
• FuelSelectionservicetool
To be supplied by Installer:
• Startingbattery
• Reinforcedconcretemountingpad
• Connectingwireandconduit
• Fuelsupplyvalves/plumbing
• Variousspecialtytools/equipment
WARNING Exhaust heat/gases could ignite combustibles
or structures resulting in death, serious injury and/or
property damage.
• DO NOT install the generator closer than 5 feet (1.5m) from any
combustibles or structures with combustible walls having a fire
resistance rating of less than 1 hour.
WARNING Running engine gives off carbon monoxide, an
odorless, colorless, poison gas.
Breathing carbon monoxide could result in death, serious
injury, headache, fatigue, dizziness, vomiting, confusion,
seizures, nausea or fainting.
• Operate this product ONLY outdoors.
• Install a battery operated carbon monoxide alarm near
the bedrooms.
• Keep exhaust gas from entering a confined area through
windows, doors, ventilation intakes, or other openings.
NOT
FOR REPRODUCTION
10
Read this operator’s manual and Important Safety Instructions before operating your generator.
Compare the illustrations of this model with your generator to familiarize yourself with the locations of various controls
and adjustments. Save this manual for future reference.
60 kW Generator
Generator is pictured with access doors removed for clarity
and screen guard open for clarity.
Exhaust Port—High-performancemufflerlowersengine
noise to comply with most codes.
Oil/Coolant Fill Door—Providesaccessforservicing
engine with oil and coolant.
Air Cleaner—Protectsenginebyfilteringdustanddebris
out of intake air.
Battery Door opening—Providesaccesstostarting
battery and air cleaner.
Oil Filter —Filtersengineoiltoprolongsystemlife.
Oil Drain Hose—Providedtofacilitateoilchanging.
Coolant Recovery Bottle—Locatedoninsideofscreen
guard. Provides visual indicator of engine coolant level.
Screen Guard—Preventsfingersfromtouchingradiator
fan and houses the coolant recovery bottle. Must stay
closed while generator is in use.
Engine Label—Identifiesenginemodelandtype.
Oil Fill Cap—Removetoservicetheenginewith
recommended oil.
Control Panel—Usedforvarioustest,operationand
maintenance functions. See System Control Panel.
Control Panel Door opening—Providesaccesstocontrol
panel, oil filter, etc. Not pictured.
Circuit Breaker Enclosure - Equipped with removable
bottom to assist with conduit connection.
ID Label(locatedonbase)—Identifiesunitby
serial number.
Oil Dip Stick—Usedtochecktheengineoillevel.
Fuel Inlet—Fuelsupplyisconnectedhere.
Controls
A
B
H
G
F
E
D
C
J
K
L
M
N
P
R
S
A B
C
D
E
F
G
H
H
J
K
L
M
N P
R S
NOT
FOR REPRODUCTION
11
Compare this control panel illustration with your generator
to familiarize yourself with the location of these important controls:
System Control Panel
Circuit Breaker—Protectsthesystemfromshortsand
other over-current conditions. Must be ON to supply
power to the automatic transfer switch.
SET EXERCISE—Usedtosettheexercisecyclestart
time and day-of-the-week. Exercise cycle only occurs in
AUTO mode.
MANUAL OVER-RIDE—WithsystemswitchinAUTO
position, push the manual over-ride button for six
seconds to start the generator. To turn off the generator,
push and hold the manual over-ride button until
engine stops.
15 Amp Fuse—ProtectsthegeneratorDCcontrol
circuits. If the fuse has ‘blown’ (melted open) or was
removed, the engine cannot crank or start. Replace the
fuse using only an identical ATO 15 Amp fuse.
System Switch—Thistwo-positionswitchisthemost
important control on the system and is used as follows:
•AUTO” position is the normal operating position.
If a utility power outage is sensed, the system
will start the generator. When utility power is
restored, AUTO lets the engine stabilize internal
temperatures, shuts off the generator, and waits
for the next utility power outage.
•OFF” position turns off running generator,
prevents unit from starting and resets any
detected faults.
Digital Display—Displaysthetotalnumberofhours
the generator has been running, fault codes, and engine
malfunctions related to emissions components.
• Hourmeterisdisplayedasaconstantnumber
and indicates the total hours of operation. Used to
schedule maintenance tasks.
• Faultconditionsaredisplayedasanalpha-numeric,
and will flash “FC_” followed by a fault code number.
Used for troubleshooting operational problems
associated with the generator. All fault conditions are
described in Fault Detection System.
• Malfunctions related to emission components are
displayed as “ENG-”. The display will flash hours
and “ENG-” in three second intervals. The engine
will continue to operate, but an authorized service
technician must be notified to diagnose, repair, and
reset the fault condition. Engine malfunctions are
described in Fault Detection System.
G
Fuel Selection Switch —Twopositionswitchused
to set engine control unit for fuel type. Used in
conjunction with mechanical switch on fuel pressure
regulator.
fault codes:
FC_1 - low battery voltage
FC_2 - low oil pressure
FC_3 - low voltage
FC_4 - engine does not start
FC_5 - low frequency
FC_6 - engine overspeed
FC_7 - high temperature
FC_8 - transfer switch
FC_9 - over voltage
A
D
B
E
C
F
A
B
C
D
E
F
G
NOT
FOR REPRODUCTION
12
The generator is equipped with an enclosure that has
several access doors. The doors are named for a significant
component located behind them, as follows:
Fuel Inlet port (shown for reference)
Control Panel door (may be one door)
Exhaust opening (shown for reference)
D
Coolant Fill door
Battery door
Muffler door
The enclosure also includes muffler and radiator access
panels, used for cleaning those components. All panels
should remain closed at all other times to assure proper
cooling, reduce noise, and for added safety.
NOTE: Doors shown in picture may differ from those on unit.
Access Ports
Each generator is equipped with a set of identical keys. These
keys fit the locks that secure the access doors.
To open access door:
1. Insert key into lock of access door handle and turn
key one quarter turn counterclockwise.
2. Grasp door’s handle and turn one quarter turn
counterclockwise to open. Remove key.
3. Coolant Fill door is unlocked in the same manner. It
can be used for adding coolant or oil.
To close access door:
1. Close door and turn door’s handle one quarter
turn clockwise.
2. Insert key into lock of door handle and turn key one
quarter turn clockwise. Remove key.
Additional force may be required to fully close and lock
the doors because they create a pressurized seal for the
generator enclosure.
WARNING Contact with muffler area could cause burns
resulting in serious injury.
• DO NOT touch hot parts and AVOID hot exhaust gases.
• Allow equipment to cool before touching.
A
D
B E
C
F
A
B
C
E
F
Screen Guard
To gain access to the engine and cooling system
components:
1. Remove two screws
A
and washers at top and
bottom of screen guard.
2. The screen guard will swing open to allow access to
the engine and cooling system components.
A
NOT
FOR REPRODUCTION
13
Operation
Battery
The installer must supply a valve-regulated, rechargeable
12 volt DC starting battery. See Battery in Final Installation
Considerations in the installation manual.
With the battery installed, all wiring to transfer switch and
generator completed, utility power supplied to the automatic
transfer switch, the 15 Amp fuse installed, and the unit in
AUTO mode, the battery receives a trickle charge while the
engine is not running. The trickle charge cannot be used to
recharge a battery that is completely discharged.
15 Amp Fuse
The generator’s 15 Amp fuse is critical for correct system
operation. Your installer will ensure the fuse is properly
installed upon completion of the installation.
Engine Oil
The engine is shipped from the factory pre-run and filled
with non-synthetic oil (API SL 10W-30). This allows for
system operation in a wide range of temperature and
climate conditions. Before starting the engine, check oil
level and ensure that engine is serviced as described in the
Maintenance section. Oil Specifications are listed on page 20.
Coolant System
This engine is shipped from the factory filled with a 50-50 mix
of automotive (Ethylene glycol) anti-freeze and water. This
will provide optimum year round protection against freezing,
boiling and corrosion. The coolant system incorporates
an optional water heater that operates when ambient
temperature is below 80ºF AND utility power is present at
the transfer switch. Before starting the engine, check coolant
level as described in the Maintenance section
Important Owner’s Considerations
WARNING Battery posts, terminals and related accessories
contain lead and lead compounds, chemicals known to the State
of California to cause cancer and reproductive harm. Wash
hands after handling.
To select automatic operation, do the following:
1. Confirm 15 Amp fuse is installed in control panel.
2. Set the main distribution panel circuit breaker that
sends utility voltage to the transfer switch to ON.
3. Set the generator’s circuit breaker to its ON position.
4. Set the control panel system switch to AUTO.
Automatic Operation
NOTICE Any attempt to crank or start the engine before it has
been properly serviced with the recommended oil will result in
equipment failure.
• Refer to Maintenance section for coolant and oil fill information.
• Damage to equipment resulting from failure to follow this
instruction will void engine and generator warranty.
CAUTION With the system switch set to AUTO, the engine could
crank and start at any time without warning, resulting in
minor or moderate injury.
• To prevent possible injury that could be caused by such sudden
starts, always set the system switch to OFF if performing
maintenance on the system.
• Remove the 15 Amp fuse before working on or around the
generator or transfer switch.
NOT
FOR REPRODUCTION
14
The generator is equipped with an exercise timer that
will start and exercise the system once every seven days.
During this exercise period, the unit runs for approximately
20 minutes and then shuts down. Electrical load transfer
DOES NOT occur during the exercise cycle (unless an utility
power outage occurs).
A button on the control panel is labeled “SET EXERCISE”
(see System Control Panel). The specific day and the specific
time of day this button is pressed is programmed into the
control board memory. This date and time is then used
to automatically initiate the system exercise cycle. The
“SET EXERCISE” legend on the control panel will flash until the
set exercise cycle is set.
Setting Exercise Timer
Checking Automatic Operation
To check the system for proper automatic operation,
proceed as follows:
1. Turn OFF main distribution panel circuit breaker
sending power to automatic transfer switch.
When utility voltage is lost and the sensor has timed
out, the engine will crank and start. Let the system go
through its entire automatic operation sequence.
2. With the generator output supplying its loads, turn
ON the service disconnect or main distribution panel
circuit breaker that supplies utility power to the
automatic transfer switch.
3. The automatic transfer switch will transfer loads back
to utility power after a 5 minute minimum run time
and utility power is available.
4. The generator will run for one additional minute for
engine cool down, then will shut down.
If utility is restored and generator does not shut down after
10 minutes, set system switch to OFF and contact your
installer or local service center.
This completes the test procedures for automatic operation.
The generator will now start automatically and will supply
power to the transfer switch when utility power is lost.
To perform the Set Exercise procedure:
1. Choose the day and time you want your generator to
exercise.
2. On that day and time, press and hold “SET EXERCISE”
for three seconds.
The “Set Exercise” display will illuminate then turn off
to confirm that the exercise timer has been set. Then
release the button.
The unit will crank and run the exercise cycle. During
the cycle, “Set Exercise” will illuminate.
Once the exercise cycle is complete, the unit will turn
off and “Set Exercise” will no longer be displayed.
The exercise cycle may be discontinued at anytime by
turning the System Switch to OFF.
3. The unit will then start and run it’s 20 minute
exercise cycle.
For example, if you press SET EXERCISE on Sunday morning
at 10:00 AM, the unit will run an immediate exercise
cycle and an exercise cycle every following Sunday at
10:00 AM (+/- 1/2 hour).
“Set Exercise” will only work if the unit is in the AUTO mode
and this exact procedure is followed. The exerciser will need
to be re-set if the 15 Amp fuse is removed or changed, or if
the starting battery is disconnected.
If you want to change the day and time the unit exercises,
simply perform the “Set Exercise” procedure at the exact
weekday and time you want it to take place.
Generator will not exercise if timer is not set.
NOT
FOR REPRODUCTION
15
Maintenance
Before performing any generator maintenance, always
perform the following steps:
1. Set generator’s circuit breaker to its OFF position.
2. Set control panel system switch to OFF.
3. Remove 15 Amp fuse from control panel.
4. Utility voltage is present at generator control panel.
Disconnect power before servicing control panel by
removing the fuses from the transfer switch.
5. After all servicing has been completed, replace fuses
in transfer switch, replace 15 Amp fuse in control
panel, set system switch and circuit breaker ON and
reset exercise timer. See Setting Exercise Timer.
Servicing the System
The generator may have to run for long periods of time
with no operator present. For that reason, the system is
equipped with sensors that automatically shut down the
generator in the event of potentially damaging conditions,
such as low oil pressure, high temperature, over speed, and
other conditions.
The generator’s control panel has a digital display that
shows fault codes, like “FC_1”. The table below lists the
detected fault, the fault code as displayed on the control
panel, and the number of LED flashes (also described as
‘blinks’) seen on the remote LED indicator.
Fault Description Fault Codes LED Flashes
Low battery voltage FC_1 1
Low oil pressure FC_2 2
Low voltage FC_3 3
Engine fails to start FC_4 4
Low frequency FC_5 5
Engine overspeed FC_6 6
High temperature FC_7 7
Transfer switch fault FC_8 8
Over voltage FC_9 9
Emission Related Fault ENG- No Flash
The remote LED indicator is installed at a convenient inside
location. The LED will remain lit when the generator is in
AUTO. Should a system fault be detected, the LED will turn
on and off in a series of blinks that identify the problem. The
blink pattern is repeated with a brief pause between each
series of blinks.
Reset Fault Detection System
The operator must reset the fault detection system each time
it activates. To do so, place the control panel system switch
in the OFF position for 30 seconds, remove the 15 Amp
fuse, remedy the fault condition, then return the generator
to service by installing the 15 Amp fuse, placing the system
switch in the AUTO position, and resetting the exercise timer.
See Setting Exercise Timer in Operation.
A description of each fault and suggested remedies are
as follows:
LED Not Blinking - Discharged Battery
If there is a detected fault condition but the LED is not
blinking, this is because the battery is completely discharged.
To remedy the problem, remove the 15 Amp fuse and
disconnect the battery from the generator. Take the battery
to a local battery store for analysis and recharging if
possible. Reinstall battery after it has been fully recharged,
connecting the NEGATIVE cable last. Then reset the fault
detection system, as described earlier.
Low Battery Voltage (FC_1)
This fault is indicated by fault code FC_1 and one blink on the
LED indicator. This condition occurs if the generator cannot
start because the starting battery output power is below that
needed to crank the engine. Causes for this problem may be
a faulty battery or battery charge circuit.
Reinstall the battery (replace if necessary - see Battery in
Final Installation Considerations in the installation manual).
Then reset the fault detection system, as described earlier.
Low Oil Pressure (FC_2)
This fault is indicated by fault code FC_2 and two blinks on
the remote LED indicator. The unit is equipped with an oil
pressure switch that uses normally closed contacts held
open by engine oil pressure during operation. Should oil
pressure drop below the 8 psi range, switch contacts close
and the engine is shut down.
To remedy the low oil pressure condition, add the
recommended oil to the FULL mark on the dipstick.
If a low oil pressure condition still exists, the engine will start,
then shut down again. The fault code will appear and the
LED will flash. To remedy the problem, contact your installer or
an authorized dealer.
Fault Detection System
NOT
FOR REPRODUCTION
16
Low Voltage (Generator, FC_3)
This fault is indicated by fault code FC_3 and three blinks on
the LED indicator. This condition is caused by a restriction
in the fuel flow, a broken or disconnected signal lead, a
failed alternator winding, the control panel circuit breaker is
open, or the generator is overloaded.To remedy the problem,
contact your installer or a GE Authorized Dealer.
Engine Fail To Start (FC_4)
This fault is indicated by fault code FC_4 and four blinks on
the LED indicator. This feature prevents the generator from
damaging itself if it continually attempts to start in spite
of another problem, such as no fuel supply. Each time the
system is directed to start, the unit will crank for 10 seconds,
pause for 10 seconds, and repeat. If the system does not
begin producing electricity after approximately 2 minutes,
the unit will stop cranking and the LED will blink.
Check to make sure the generator’s circuit breaker is in the
ON position in order for the sensing leads to verify that the
unit is running.
The most likely cause of this problem is no fuel supply. Check
the internal and external fuel shut off valves to ensure they
are fully open. Other causes could be failed spark plug(s),
failed engine ignition, or the engine air filter is clogged. You
may need to contact your installer for assistance if you can’t
remedy these problems.
Low Frequency (FC_5)
This fault is indicated by fault code FC_5 and five blinks on
the LED indicator. This feature protects devices connected
to the transfer switch by shutting the generator down if the
engine runs slower than 55 Hz for three seconds.
This condition is caused by a failed engine component or by
excessive loads on the generator. To remedy the problem,
contact your installer or an authorized dealer.
Engine Overspeed (FC_6)
This fault is indicated by fault code FC_6 and six blinks on the
LED indicator. This feature protects devices connected to the
transfer switch by shutting the generator down if the engine
happens to run faster than the preset limit.
The overspeed fault is detected as follows:
• Ifthegeneratoroutputfrequencyis65-70Hz,after
three seconds, the generator will shut down.
• Ifthegeneratoroutputfrequencyisgreaterthan
70 Hz, the generator will shut down immediately.
This condition is caused by a failed engine component.
To remedy the problem, contact your installer or an
authorized dealer.
High Temperature (FC_7)
This fault is indicated by fault code FC_7 and seven blinks on
the LED indicator. The contacts of the temperature switch
are normally open. If the engine temperature exceeds
approximately 115°C (240°F), the fault is detected and the
engine shuts down.
Common causes for this condition include running the
unit with all access doors removed, obstructed air inlet or
exhaust port, low oil or coolant level, or debris in the engine
compartment or radiator.
To resolve the problem, let the engine cool down and remove
any accumulated debris and obstructions. Ensure that the
access doors are installed whenever the unit is running.To
remedy the problem, contact your installer or an
authorized dealer.
Transfer Switch Fault (FC_8)
This fault is indicated by fault code FC_8 and eight blinks
on the LED indicator (if transfer switch is equipped with
fault detection).
The most likely cause of this fault is a blown fuse in the
transfer switch. To remedy the problem, contact your installer
or an authorized dealer.
Over Voltage (FC_9)
This fault is indicated by fault code FC_9 and nine blinks on
the LED indicator. This feature protects devices connected
to the transfer switch by shutting the generator down if the
generator output voltage happens to increase above the
preset limit.
The overvoltage fault is detected as follows:
•Ifthegeneratoroutputvoltageisover229voltsfor
208VAC, after three seconds, the generator will shut down.
•Ifthegeneratoroutputvoltageisover264voltsfor
240VAC, the generator will shut down immediately.
This condition is most likely caused by a failed voltage
regulator, alternator excitation circuit or a load imbalance. To
remedy the problem, contact your installer or an
authorized dealer.
ENG-
The engine is equipped with on-board diagnostics that
monitor the operation of emission related components. If
an emission related problem has been detected, the system
control panel display will alternate between run hours and
ENG- in three second intervals while the generator is running.
If ENG- displays while the generator is running, a diagnostic
trouble code may be set or a problem may exist in the
system which has caused the engine emissions to go outside
the standards certified by the Environmental Protection
Agency. It is the responsibility of the operator to contact an
authorized service technician to repair this condition.
NOT
FOR REPRODUCTION
17
Generator maintenance consists of keeping the unit clean.
Operate the unit in an environment where it will not be
exposed to excessive dust, moisture or any corrosive vapors.
Cooling air louvers on the enclosure must not become
clogged with snow, leaves, or any other foreign material. To
prevent generator damage caused by overheating, keep the
enclosure cooling inlets and outlets clean and unobstructed
at all times.
Check the cleanliness of the unit frequently and clean when
dust, dirt, oil, moisture or other foreign substances are visible
on its exterior/interior surface. Inspect the air inlet and outlet
openings inside and outside the enclosure to ensure air flow
is not blocked.
DO NOT use direct spray from a garden hose to clean
generator. Water can enter the engine and generator and
cause problems.
Generator Maintenance
Cleaning the Generator
1. Set control board system switch to OFF.
2. Remove 15 Amp fuse from control panel.
3. Clean generator as desired.
• Useadampclothtowipeexteriorsurfacesclean.
• Useasoft,bristlebrushtoloosencakedondirt,etc.
• Useavacuumcleanertopickuploosedirtanddebris.
• Uselowpressureair(nottoexceed25psi)toblow
away dirt. Inspect cooling air slots and openings on
the generator. These openings must be kept clean
and unobstructed.
4. Reinstall 15 Amp fuse in control panel.
5. Set generator’s system switch to AUTO.
6. Reset exercise timer. See Setting Exercise Timer.
NOTICE Improper treatment of generator can damage it and
shorten its life.
• DO NOT expose generator to excessive moisture, dust, dirt, or
corrosive vapors.
• DO NOT insert any objects through cooling slots.
Engine Maintenance
The maintenance of an engine and related components are
critical to its operating performance and lifespan. Industrial
engines operate in an environment that often include hot
and cold temperatures and extreme dust. The recommended
maintenance schedule is listed in this section, however,
environmental operating conditions and additional installed
equipment may require more frequent inspection and
servicing.
The owner and/or authorized service technician should
review the operating conditions of the equipment to
determine the inspection and maintenance intervals. Proper
engine cooling and lubrication are very important, so pay
particular attention to these matters.
The engine is shipped from the factory pre-run and filled
with non-synthetic oil (API SL 10W-30). This allows for
system operation in a wide range of temperature and
climate conditions.
Engine Oil
Synthetic Oils
Synthetic oils have been available for use in industrial
engines for a relatively long period of time and may offer
advantages in cold and hot temperatures. However, it is not
known if synthetic oils provided operational or economic
benefits over conventional petroleum-based oils in industrial
engines.
Use of synthetic oils does not permit the extension of oil
change intervals.
Oil Specifications are listed on the next page.
NOT
FOR REPRODUCTION
18
Oil Recommendation
HOT WEATHER
COLD WEATHER
SAE 10W-30
PREFERRED
SAE 15W-40
FOR THE BEST FUEL ECONOMY AND COLD STARTING, SELECT THE LOWEST
SAE VISCOSITY GRADE OIL FOR THE EXPECTED TEMPERATURE RANGE
IF NEITHER SAE 10W-30
NOR SAE 15W-40 GRADE
OILS ARE AVAILABLE, SAE
30 GRADE MAY BE USED AT
TEMPERATURES ABOVE 4
DEGREES C (40F), SAE 40
GRADE AY BE USED AT
TEMPERATURES ABOVE 27
DEGREES C (80F).
DO NOT USE SAE 10W-40
GRADE OIL OR ANY OTHER
GRADE NOT RECOMMENDED
RECOMMENDED SAE VISCOSITY GRADE ENGINE OILS
Select an engine oil viscosity that will best match the
prevailing daytime temperature.
The oil must meet GM specification 9986231. Motor oils
meeting this specification receive the API (American
Petroleum Institute) starburst symbol.
It is noted that the GF-4 oils are also “backwards compatible”
and are equal or better that previous grades of oil in all
aspects.
Checking Engine Oil Level
NOTICE It is important to be careful when checking engine oil
level. Oil must be maintained between “ADD” and the “FULL”
mark on the dipstick. To ensure that you are not getting a
false reading, make sure the following steps are taken before
checking the oil level.
1. Stop engine.
2. Set control board system switch to OFF.
3. Remove 15 Amp fuse from control panel.
4. Allow approximately five minutes for the oil to drain
back into the oil pan.
5. Remove the dipstick. Wipe with a clean cloth or paper
towel and reinstall. Push the dipstick all the way into
the dipstick tube.
6. Remove the dipstick and note the amount of oil on the
dipstick. The oil level must be between the “ADD” and
“FULL” marks.
7. If the oil level is below the “ADD” mark, reinstall the
dipstick and proceed to step 8.
8. Remove the oil filler cap from the valve cover.
9. Add the required amount of oil to bring the level up to,
but not over the “FULL” mark on the dipstick. Reinstall
the oil filler cap to valve rocker arm cover and wipe
any excess oil clean.
NOT
FOR REPRODUCTION
19
Changing Engine Oil and Oil Filter
KEEP OUT OF REACH OF CHILDREN. DON’T POLLUTE.
CONSERVE RESOURCES. RETURN USED OIL TO
COLLECTION CENTERS.
Change oil while the engine is still warm from running.
1. Set control board system switch to OFF.
2. Remove 15 Amp fuse from control panel.
3. Place oil drain hose (B) into an approved container.
4. Open valve (A) located on bottom of oil pan.
5. When oil has drained, replace brass fitting on hose.
6. Remove oil filter and dispose of properly.
7. Before installing a new oil filter, lightly lubricate the oil
filter gasket with fresh, clean oil.
8. Install the oil filter by hand until the gasket contacts
the oil filter adapter, then tighten the oil filter ½ to ¾
turn.
9. Add the required amount of oil to bring the level up to,
but not over the “FULL” mark on the dipstick. Reinstall
the oil filler cap to valve rocker arm cover and wipe
any excess oil clean.
10. If all engine servicing is complete, replace 15 Amp
fuse in control panel and reset exercise timer. See
Setting Exercise Timer in Operation.
To make the task of adding oil more convenient, we
recommend use of a funnel attahced to a length of tubing long
enough to reach from the Coolant Fill door to the oil fill opening
on the engine valve cover.
CAUTION Avoid prolonged or repeated skin contact with used
motor oil.
• Used motor oil has been shown to cause skin cancer in certain
laboratory animals.
• Thoroughly wash exposed areas with soap and water.
A
C
B
B
A
NOT
FOR REPRODUCTION
20
Coolant
With the engine cold, check the coolant level in the coolant
recovery bottle (see Controls). Specifications for the coolant
system can be found in the Maintenance chart of this
manual. Coolant Specification - ethylene-glycol 50-50
mixture with distilled water.
WARNING Hot pressurized coolant can cause severe injury
and/or property damage.
• DO NOT open radiator cap when hot.
• Before servicing, allow coolant to cool.
Engine Coolant System
It is important that the cooling system of the engine be
maintained properly to ensure proper performance and
longevity.
NOTICE Alcohol or methanol based anti-freeze or plain water
are not recommended for use in the cooling system at any
time.
The cooling system must be maintained according to the
recommended maintenance schedule and inspection should
include:
• Theregularremovalofdust,dirt,debrisfromthe
radiator core and fan shroud.
• Inspectionofcoolanthosesandcomponentsforleaks,
especially at the radiator hose connections. Tighten
hose clamps if necessary.
• Checkradiatorhosesforswelling,separation,
hardening, cracks, or any type of deterioration.
• Inspecttheradiatorcaptoensurepropersealing.
Engine V-Belts
The engine installed in this equipment uses drive belt(s) that
drive the water pump and alternator. The drive belt(s) are an
integral part of the cooling and charging system and should be
inspected according to the maintenance schedule.
When inspecting the belts, check for:
• Cracks
• Chunkingofthebelt
• Splits
• Materialhangingloosefromthebelt
• Glazing,hardening
If any of these conditions exist, the belt should be replaced.
NOT
FOR REPRODUCTION
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100

Simplicity 076062-00 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur
Ce manuel convient également à