Troubleshooting PLB40
14
The display shows the
warning symbol and the
low/ high temperature sym-
bol flashes. The device
beeps for 15 seconds and
then switches off automati-
cally during discharging.
The ambient temperature for
discharging the device is too
low / high.
Stop discharging the device.
Turn the device off. Wait until
the ambient temperature
comes to a permitted value
(chapter “Technical data” on
page 16).
The display shows the warn-
ing symbol and the fuse
blown symbol flashes. An
error sound is continuously
beeping for 30 seconds.
The DC output fuse has
blown. Additionally the DC
symbol flashes in the display.
Turn the device off.
Change the DC fuse (chapter
“Replacing fuses” on
page 13).
The 2-PIN fuse has blown.
Additionally the 2-PIN
symbol flashes in the display.
Turn the device off.
Change the 2-PIN fuse (chap-
ter “Replacing fuses” on
page 13).
The display shows the warn-
ing symbol and the charge
arrow symbol flashes. An
error sound is continuously
beeping.
The input voltage of the
charger is wrong.
Turn the charger off. Connect
a charger with the standard
charge voltage (chapter
“Technical data” on
page 16).
The display shows the warn-
ing symbol. The discharge
arrow and either the USB or
2-pin or DC symbol flashes.
An error sound is beeping for
60 seconds.
Over current protection was
triggered.
Turn the device off. Release
some of the load before
switching the device on
again.
Short circuit protection was
triggered.
Turn the device off. Clear the
short circuit before switching
the device on again.
The battery symbol is flash-
ing. An error sound beeps
every 3 seconds for 10 times.
After the beeps the device
switches off automatically.
The battery capacity is 0 %. Charge the device.
The letters and symbols on
the display are fading.
The display is overheated. Place the battery pack in a
cool environment.
The display is defective. Contact a service center.
Problem Cause Remedy
PLB40-OPM-EMEA16.book Seite 14 Dienstag, 31. März 2020 6:44 06