Lamp Size ED17 Profile
E26 base with E39/EX39 adapter
Type B LED
Hazardous Rated Lamp
120-277V
BEFORE YOU BEGIN
Read these instructions completely and carefully.
Save these instructions for future use.
Installation Guide
Type B 21/35/45W Hazardous Rated Lamp 120-277V
LEDL090 (A-1027119)
Risk of electrical shock or fire. Before installing this kit in
a luminaire, make sure the luminaire matches the features
and dimensions indicated in the photographs and that the
input rating of the retrofit kit does not exceed the input
rating of the luminaire. This product is rated 120-277 V,
however in the US it should only be used on branch circuits
permied in Section 210.6 of the US National Electrical
Code for E26/E39/EX39 lamp holders.
WARNING
DO NOT MAKE OR ALTER ANY OPEN HOLES IN AN
ENCLOSURE OF WIRING OR ELECTRICAL COMPONENTS
DURING KIT INSTALLATION.
Do not expose wiring to edges of sheet metal or other
sharp objects to prevent wiring damage or abrasion.
WARNING
CONTACT A QUALIFIED ELECTRICIAN if you are not
knowledgeable about luminaires and electrical systems. This
LED Retrofit Kit Installation requires a familiarity with safety
procedures, if not qualified, do not aempt installation.
DO NOT disconnect the existing wires from lamp holder
terminals in preparation for new connections. Cut the existing lamp
holder terminal wires an appropriate distance from the connection point and use two connectors to aach the new wires.
THE RETROFIT KIT IS FOR RETROFITTING LUMINAIRES IDENTIFIED IN THE LUMINAIRE FITTINGS REFERENCE TABLE. PRODUCT MUST
BE INSTALLED BY A QUALIFIED ELECTRICIAN
IN ACCORDANCE WITH THE APPLICABLE AND APPROPRIATE ELECTRICAL CODES.
ENSURE
CURRENTLY INSTALLED LUMINAIRE AND RETROFIT KITS ARE ONLY INSTALLED IN THE SAME HAZARDOUS CLASSIFIED LOCATIONS
AND MAXIMUM AMBIENT TEMPERATURES SPECIFIED ON THE RETROFIT KIT MARKING LABEL.
Input Rating
LED45ED17/YXX/HAZ 120-277V, 0.39 amps max, 45W
LED35ED17/YXX/HAZ 120-277V, 0.33 amps max, 35W
LED21ED17/YXX/HAZ 120-277V, 0.19 amps max, 21W
The Kit Includes:
1. LED lamp
2. Label for modified luminaire
3. Installation instructions
4. Wire connectors (2)
5.
E26 to E39 socket adapter
Tools needed:
1. Sloed screwdriver and adjustable wrench
2. Wire cuer
3. Wire stripper
4. Small flat blade screwdriver
NOTE: The luminaire does not need to be removed from the
mounting surface prior to modification.
Luminaire Fiings Reference Table
Luminaire Fiing Page
GE Lighting Filtr-Gard
®
3
Crouse-Hinds Champ
®
VMV 3
Appleton Mercmaster
®
III 4
Appleton Mercmaster
®
II 4
Hubbell Killark
®
VM Series 5
Holophane Petrolux
®
P3M 5
Thomas & Bes Hazlux
®
3 Series 6
GE Lighting Powr-Gard
®
H9 Series 6
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information and specifications subject to change without
notice. All values are design or typical values when measured under laboratory conditions.
Page 1 of 12
(Rev 05/09/23)
LEDL090_R01
WARNING
Disconnect electrical power to the luminaire at the supply source.
CAUTION
Avoid burn risk - allow luminaire and lamp to cool before
proceeding.
C1 Label: for Class I, Division 2, Group A, B, C, D hazardous locations
C1/C2 Label: for Class I, Division 2, Groups A, B, C, D; Class II, Division 1, Groups E, F, G; Class II, Division 2, Groups F, G hazardous locations
Refer to Table 2 for correct new label selection.
The new label specifies the replacement lamp, the hazardous location classification area and electrical ratings.
Luminaire Fiing C1 Label C1/C2 Label C2 Label
GE Lighting Filtr-Gard
®
All options - -
Crouse-Hinds Champ
®
VMV
All other options G24 -
Appleton Mercmaster
®
III Mounting covers with sux PC12D2 and PC27D2 All other options
Appleton Mercmaster
®
II Mounting covers with sux PC12D2 and PC27D2,
Mounting covers LPWB-75, LPWB-100 All other options -
Hubbell Killark
®
VM Series - All options -
Holophane Petrolux
®
P3M - All options -
Thomas & Bes Hazlux
®
3 Series Mounting covers VS4, VS5 All other options -
GE Lighting Powr-Gard H9 Series - - All options
Table 2: Modified Luminaire Label Application Guide
45W models21W models
C2 Label: for Class II, Division 1, Groups E, F, G; Class II, Division 2, Groups F, G hazardous locations
35W models
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information and specifications subject to change without
notice. All values are design or typical values when measured under laboratory conditions.
Page 2 of 12
(Rev 05/09/23)
LEDL090_R01
Installation GuideType B 21/35/45W LED Hazardous Rated Lamp 120-277V
3. Cut the black and white wires from the quick disconnect to the ballast
circuitry leaving as much wire aached to the quick disconnect as
possible. Be careful to leave the green ground wire connected.
4. Cut the white (neutral) and color (hot) wires from the lamp holder in the
center of the ballast housing, leaving as much wire aached to the lamp
holder as possible.
Instructions for retrofiing UL Listed GE Lighting Filtr-Gard® Luminaire
Fiing/Ballast Housing marked for use in USA only in Class I, Division 2,
Groups A,B,C,D; hazardous locations.
1
5
Retrofiing GE Lighting Filtr-Gard
®
A
Wiring
Lamp Installation Instructions
Lamp holder wires AC input to ballast
Fiing Filtr-Gard
®
Catalog#
Ballast Housing Series H2 ballast housings
Cover/Mounting Series H2000 mounts
Optical Assmeblies
Series H2000 opticals
5.
Strip 3/8 inch from the snipped quick disconnect wires (from step 3)
and the snipped lamp holder wires (from step 4). Using the included wire
connectors, connect white to white and black
to color (may be black).
6. Place the ballast housing hinge pin over the cover hinge. Reconnect
the mains quick disconnect device. Ensure no wires are pinched when
tightening the cover screw.
7. If there is an optical guard, remove by rotating counter-clockwise, or
removing retaining screws.
8. Remove the optical by gently turning in a counter-clockwise direction.
9. Remove old HID lamp and inspect socket for signs of wear and/or arcing.
Contact original luminaire manufacturer for replacement parts if needed.
10. If the old lamp has an E39 mogul base, install lamp with the supplied
E26 to E39 adapter into the luminaire socket. If the luminaire has an
E26 socket, remove the adapter from the lamp. Refer to the Lamp Base
Adapter Usage Table.
11. Install the new LED lamp, ensuring the lamp
is properly seated.
12. Reinstall the optical and guard (if supplied)
to their original positions.
13. Refer to Table 2 for correct new label selection.
The new label specifies the replacement lamp,
the hazardous location classification area and
electrical ratings. Clean the area and then apply
new label to a visible location on the housing.
14. Restore power to the luminaire.
Filtr-Gard
®
is a registered trademark of General
Electric Company.
Retrofiing Crouse-Hinds Champ
®
B
Instructions for retrofiing UL Listed Crouse-Hinds Champ® VMV Series HID
Luminaire Fiing/Ballast Housing marked for use in Class I, Division 2, Groups A,B,C,D;
Class II, Division 1, Groups E,F,G; Class II, Division 2, Groups F, G hazardous locations.
Fiing Champ® Catalog#
Ballast Housing VMVS & VMVM
Champ Cover
(Mounting Module)
APM2, APM3, HPM2, CM2, CM3, TWM2,
TWM3, JM5, PM5, QM25
Optical & Guard
Components
G24, S808*, P21*, RD70*, RA70*, G241*, G243*,
G245*, P241*, R2*, R3*, R5*, P23*
Wiring
4
1. Loosen the screw that holds the ballast
housing and cover together.
2.
Hinge open the ballast cover.
3. Remove wire connectors between incom-
ing wires and ballast circuitry. Be careful to
leave the green ground wire connected.
1
AC input wires
4. Remove wire connectors from the lamp holder wires.
5. Connect the lamp holder wires to incoming wires, using the
included
wire connectors. Connect white to white and black to black.
6. Place the ballast housing hinge pin over the cover hinge. Close and
secure the ballast housing and cover by tightening the screw. Ensure no
wires are pinched when closing luminaire.
5
Lamp holder wires
Lamp Installation Instructions
7. Unthread the optical assembly to remove guards, globes, or external reflectors.
8
. Remove old HID lamp and inspect socket for signs of wear and/or arcing.
Contact original luminaire manufacturer for replacement parts if needed.
9. If the old lamp has an E39 mogul base, install lamp with the supplied E26 to
E39 adapter into the luminaire socket. If the luminaire has an E26 socket, re-
move the adapter from the lamp. Refer to the Lamp Base Adapter Usage Table.
10. Install the new LED lamp, ensuring the lamp is
properly seated.
11. Thread optical assembly into ballast housing.
12.
Refer to Table 2 for correct new label selection. The
new label specifies the replacement lamp, the hazard-
ous location classification area and electrical ratings.
Clean the area and then apply new label to a visible
location on the housing.
13. Restore power to the luminaire.
1. Loosen the screw that holds the ballast
housing and cover together.
2.
Hinge open the ballast cover and pull
apart the two black plastic connectors to
separate the quick disconnect function
located between the cover and housing.
Lamp Base Adapter Usage
Ballast Housing Adapter Utilization
H2*0 SK, H2*05L, H2* 10M Remove adapter from the lamp
All others Use supplied adapter
Lamp Base Adapter Usage
Ballast Housing Adapter Utilization
VMV5050, VMVM070, VMVM100 Remove adapter from the lamp
All others Use supplied adapter
* Class I, Division 2 only
Champ® is a registered trademark of Eaton’s Crouse-Hinds.
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information and specifications subject to change without
notice. All values are design or typical values when measured under laboratory conditions.
Page 3 of 12
(Rev 05/09/23)
LEDL090_R01
Installation GuideType B 21/35/45W LED Hazardous Rated Lamp 120-277V
Instructions for retrofiing UL Listed Appleton Mercmaster
®
III Series
HID Luminaire Fiing/Ballast Housing marked for use in
Class I, Division
2, Groups A,B,C,D; Class II, Division 1, Groups E,F,G; Class II, Division 2,
Groups F,G hazardous locations.
Wiring
3. Remove wire connectors between incoming wires and ballast circuitry.
Disconnect the incoming wire to the fuse if the device has one. Discard all the
fuses if applicable. Be careful to leave the green ground wire connected.
4. Remove wire connectors from the lamp holder wires, which may be
bundled together with other wires. Carefully trace all wires from the lamp
holder. Discard any additional white wires.
1. Loosen the nut that holds the ballast
housing and cover together.
2. Hinge open the ballast cover.
1
Retrofiing Appleton Mercmaster
®
C
3
AC input wires
Fiing Mercmaster® III Catalog#
Ballast Housing MLBG, MLBR, KPB & KPBR
Mounting Hood* KPA75, KPA100, KPAF75, KPAF100, KPC75,
KPC100, KPCH75, KPCH100, KPS125, KPS150,
KPST125, KPST150, KPWB75, KPWB100
Optical & Guard
Components
CMR-4AN/4ST, KR2-AN/ST, KRG2, KGU2,
LPG-R1/R3/R5 LPRF-2/3/4/5CP, VPGL-2HR/3HR
Lamp Installation Instructions
7. Loosen screws and unthread the optical assembly to remove guards,
globes, or external reflectors.
8. Remove old HID lamp and inspect socket for signs of wear and/or arcing.
Contact original luminaire manufacturer for replacement parts if needed.
9. If the old lamp has an E39 mogul base, install lamp with the supplied E26 to
E39 adapter into the luminaire socket. If the luminaire has an E26 socket, re-
move the adapter from the lamp. Refer to the Lamp Base Adapter Usage Table.
10. Install the new LED lamp, ensuring the lamp is
properly seated.
11. Thread optical assembly into ballast housing.
12.
Refer to Table 2 for correct new label selection.
The new label specifies the replacement lamp, the
hazardous location classification area and electrical
ratings. Clean the area and then apply new label to
a visible location on the housing.
13. Restore power to the luminaire.
Mercmaster® is a registered trademark of Appleton Grp.
5. Connect the lamp holder wires to incoming wires, using the
included wire connectors. Connect white to white and black to black.
6. Place the ballast housing hinge pin over the cover hinge. Close and se-
cure the ballast housing and cover by tightening the screw.
5
Lamp holder wires
Retrofiing Appleton Mercmaster
®
D
Instructions for retrofiing UL Listed Appleton Mercmaster
®
II Series
HID Luminaire Fiing/Ballast Housing marked for use in
Class I, Division
2, Groups A,B,C,D; Class II, Division 1, Groups E,F,G; Class II, Division 2,
Groups F,G hazardous locations.
Fiing Mercmaster® II Catalog#
Ballast Housing LPB, 4 ¾” height housing only
Mounting Hood*
LPA-75, LPA-100, LPC-75, LPC-100, LPWB-75**,
LPWB-100**, LPS-125, LPS-150
Optical & Guard
Components
LPRF-2CG/5CG, VPGL-2HR, KGU2, KR2-ST/AN,
VPGU2, LPG-R1/R3/R5
1
3. Remove wire connectors between incoming wires and ballast circuitry. Be
careful to leave the green ground wire connected.
4. Locate the wire tie and cut it, separate the wiring from the bundle. Remove
wire connectors from the lamp holder wires. Discard any additional white
wires. The lamp holder wires are black and white and come from under the
ballast housing. The ballast is under the bracket in the center of the housing.
3
AC input wires
Wiring
1. Loosen the nut that holds the bal-
last housing and cover together.
2. Hinge open the ballast cover.
5. Connect the lamp holder wires to incoming wires, using the
included wire connectors. Connect white to white and black to black.
6. Place the ballast housing hinge pin over the cover hinge. Close and
secure the ballast housing and cover by tightening the nut.
5
Lamp holder wires
Lamp Installation Instructions
7. Loosen screws and unthread the optical assembly to remove guards,
globes, or external reflectors.
8. Remove old HID lamp and inspect socket for signs of wear and/or arcing.
Contact original luminaire manufacturer for replacement parts if needed.
9. If the old lamp has an E39 mogul base, install lamp with the supplied E26 to
E39 adapter into the luminaire socket. If the luminaire has an E26 socket, re-
move the adapter from the lamp. Refer to the Lamp Base Adapter Usage Table.
10. Install the new LED lamp, ensuring the lamp is
properly seated.
11. Thread optical assembly into ballast housing.
12.
Refer to Table 2 for correct new label selection. The
new label specifies the replacement lamp, the hazard-
ous location classification area and electrical ratings.
Clean the area and then apply new label to a visible
location on the housing.
13. Restore power to the luminaire.
Mercmaster® is a registered trademark of Appleton Grp.
* Mounting covers with sux “PC12D2” or “PC27D2” are Class I, Division 2 only
** Class I, Division 2 only
* Mounting covers with sux “PC12D2” or “PC27D2” are Class I, Division 2 only
Lamp Base Adapter Usage
Ballast Housing Adapter Utilization
MLBG, MLBR Remove adapter from the lamp
KPB, KPBR Use supplied adapter
Lamp Base Adapter Usage
Ballast Housing Adapter Utilization
LPB, 4 ¾”height housing only Use supplied adapter
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information and specifications subject to change without
notice. All values are design or typical values when measured under laboratory conditions.
Page 4 of 12
(Rev 05/09/23)
LEDL090_R01
Installation GuideType B 21/35/45W LED Hazardous Rated Lamp 120-277V
3. Remove wire connectors between incoming wires and ballast
circuitry. Be careful to leave the green ground wire connected.
4. Remove wire connectors from the lamp holder wires.
3
AC input wires
5. Connect the lamp holder wires to incoming wires, using the included
wire connectors. Connect white to white and black to black.
6. Place the ballast housing hinge pin over the cover hinge. Close and
secure the ballast housing and cover by tightening the screw. Ensure no
wires are pinched when closing fixture.
5
Lamp Holder Leads
1
Retrofiing Hubbell Killark®
E
Instructions for retrofiing UL Listed Hubbell Killark
®
VM Series HID Lumi-
naire Fiing/Ballast Housing marked for use in
Class I, Division 2, Groups
A,B,C,D; Class II, Division 1, Groups E,F,G; Class II, Division 2, Groups F,G
hazardous locations.
Wiring
1. Loosen the screw that holds the ballast
housing and cover together.
2. Hinge open the ballast cover.
Lamp Installation Instructions
7. Unthread the optical assembly to remove guards, globes, or external
reflectors.
8. Remove old HID lamp and inspect socket for signs of wear and/or arcing.
Contact original luminaire manufacturer for replacement parts if needed.
9. If the old lamp has an E39 mogul base, install lamp with the supplied E26 to
E39 adapter into the luminaire socket. If the luminaire has an E26 socket, re-
move the adapter from the lamp. Refer to the Lamp Base Adapter Usage Table.
10. Install the new LED lamp, ensuring the lamp is
properly seated.
11. Thread optical assembly into ballast housing.
12. Refer to Table 2 for correct new label selection.
The new label specifies the replacement lamp, the
hazardous location classification area and electrical
ratings. Clean the area and then apply new label to a
visible location on the housing.
13. Restore power to the luminaire.
Retrofiing Holophane Petrolux
®
P3M
F
Instructions for retrofiing UL Listed Holophane Petrolux
®
P3M series HID Lu-
minaire Fiing/Ballast Housing marked for use in
Class I, Division 2, Groups
A,B,C,D for USA and Canada; Class II, Division 1, Groups E,F,G; Class II,
Division 2, Groups F,G hazardous locations for USA only.
Fiing Holophane P3M Refractor
Ballast Housing
HID Source, 50-175 wa HPS or MH
Mounting Hood
ST, WL, PD, CE, UN
Optical
Components
541, 545, GD
Wiring
1. Loosen the bolt that holds the ballast
housing and cover together.
2. Hinge open the ballast cover.
1
3. Remove wire connectors between incoming wires and ballast circuitry.
Disconnect the incoming wire to the fuse if the device has one. Discard all the
fuses if applicable. Be careful to leave the green ground wire connected.
4. Remove wire connectors from the lamp holder wires, which may be bundled
together with other wires. Carefully trace all wires from the lamp holder. Dis-
connect any additional wires from the lamp holder white and black leads.
3
AC input wires
5. Connect the lamp holder wires to incoming wires, using the
included
wire connectors. Connect white to white and black to black.
6. Place the ballast housing hinge pin over the cover hinge. Close and
secure the ballast housing and cover by tightening the screw.
5
Lamp Holder Wires
Lamp Installation Instructions
7. Remove optical assembly by turning black tabs around optical counter-
clockwise.
8. Remove old HID lamp and inspect socket for signs of wear and/or arcing.
Contact original luminaire manufacturer for replacement parts if needed.
9. If the old lamp has an E39 mogul base, install lamp with the supplied E26 to
E39 adapter into the luminaire socket. If the luminaire has an E26 socket, re-
move the adapter from the lamp. Refer to the Lamp Base Adapter Usage Table.
10. Install the new LED lamp, ensuring the lamp
is properly seated.
11. Thread optical assembly into ballast housing.
12. Refer to Table 2 for correct new label selection.
The new label specifies the replacement lamp,
the hazardous location classification area and
electrical ratings. Clean the area and then apply
new label to a visible location on the housing.
13. Restore power to the luminaire.
Fiing Killark® Catalog#
Ballast Housing
VM1, VM2, VM3, VM4, VM5, VMLO, VMMO
Cover
(Mounting
Module)
VMA2B, VMA3B, VMB2B, VMB3B, VMC2B, VMC3B,
VMD4B, VMD5B, VMF2B, VMF3B, VMS4B, VMS5B,
VMX2B, VMX3B, VMX6B, VMX7B, VMX8B, VMX9B
Optical &
Guard
Components
VMG17, VMG25, VMR171, VMR175, VMR251, VMR253,
VMR255, VZRG1550, VZRG2520, VZRG2550,
VMAG17, VMAG25S, VMERG, VMRWG, VMRWG8,
VMRERG, VMPSD40, VMPA40, VMEP40, VMER40,
VMG40, VZRG4050, VZRG4020, VMAG40S
Lamp Base Adapter Usage
Ballast Housing Adapter Utilization
VM1, VM2 Remove adapter from the lamp
VM3, VM4, VM5, VMLO, VMMO Use supplied adapter
Lamp Base Adapter Usage
Ballast Housing Adapter Utilization
MH Source (E26 socket) Remove adapter from the lamp
HPS or MH Source (E39 socket) Use supplied adapter
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information and specifications subject to change without
notice. All values are design or typical values when measured under laboratory conditions.
Page 5 of 12
(Rev 05/09/23)
LEDL090_R01
Installation GuideType B 21/35/45W LED Hazardous Rated Lamp 120-277V
Retrofiing Thomas & Bes Hazlux®
G
Instructions for retrofiing UL Listed Thomas & Bes Hazlux
®
3 Series
HID Luminaire Fiing/Ballast Housing marked for use in
Class I, Division 2,
Groups A,B,C,D; Class II, Division 1, Groups E, F, G; Class II, Division 2,
Groups F,G hazardous locations.
Fiing Thomas & Bes Hazlux
®
Catalog#
Ballast Housing
DS, DH
Mounting Hood
VA2, VA3, VB2, VB3, VC2, VC3, VF2, VF3,
VL4, VL5, VP2, VP3, VS4*, VS5*
Optical & Guard
Components
VGT22, VGT22TS, VGT31S, VGT31STS, VRF22C5,
VRF31C5, VGL31R1, VGL31R3, VGL31R5, VR31CB,
VGR48, VGR64, VGU22, VGU22P, VGU31R,
VGU31RP, VRA22P, VR22P, VR31P, VRA31P
Wiring
1. Loosen the bolt that holds the ballast
housing and cover together.
2. Hinge open the ballast cover.
3
3. Remove wire connectors between incoming wires and ballast circuitry.
Disconnect the incoming wire to the fuse if the device has one. Discard all the
fuses if applicable. Be careful to leave the green ground wire connected.
4. Remove wire connectors from the lamp holder wires, which may be bun-
dled together with other wires. Carefully trace all wires from the lamp holder.
Disconnect any additional wires from the lamp holder white and black leads.
AC input wires
5. Connect the lamp holder wires to incoming wires, using the
included wire connectors. Connect white to white and black to black.
6. Place the ballast housing hinge pin over the cover hinge. Close and
secure the ballast housing and cover by tightening the screw.
5
Lamp holder wires
Lamp Installation Instructions
7. Loosen screws and unthread the optical assembly to remove guards,
globes, or external reflectors.
8. Remove old HID lamp and inspect socket for signs of wear and/or arcing.
Contact original luminaire manufacturer for replacement parts if needed.
9. If the old lamp has an E39 mogul base, install lamp with the supplied E26 to
E39 adapter into the luminaire socket. If the luminaire has an E26 socket, re-
move the adapter from the lamp. Refer to the Lamp Base Adapter Usage Table.
10. Install the new LED lamp, ensuring the lamp is properly
seated.
11. Thread optical assembly into ballast housing.
12.
Refer to Table 2 for correct new label selection. The new
label specifies the replacement lamp, the hazardous location
classification area and electrical ratings. Clean the area and
then apply new label to a visible location on the housing.
13. Restore power to the luminaire.
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation,
operation or maintenance. Should further information be desired or should particular problems arise which are not covered suciently for the purchaser’s purposes, the
maer should be referred to Current.
1
* Class I, Division 2 only
Lamp Base Adapter Usage
Ballast Housing Adapter Utilization
MH Source (E26 socket) Remove adapter from the lamp
HPS or MH Source (E39 socket) Use supplied adapter
Retrofiing GE Lighting Powr-Gard
®
H
Instructions for retrofiing UL Listed GE Lighting Powr-Gard® Luminaire Fiing/
Ballast Housing marked for use in
Class II, Division 1, Groups E,F,G; Class II,
Division 2, Groups F,G hazardous locations.
Fiing Powr-Gard® Catalog#
Ballast Housing Series H9 ballast housings
Cover/Mounting 3C, 3F, 3P, 3W, 4C, 4F, 4P, 4W, 5J, 5S
Optical & Guard Components JJ, JN, GG, GN
Wiring
1. Loosen the setscrew with a small flat
blade screwdriver and remove the optical
assembly by rotataing counterclockwise.
2. Remove old HID lamp and inspect
socket for signs of wear and/or arcing.
Contact original luminaire manufacturer
for replacement parts if needed.
1
3. Remove ballast cover
plate. Locate wires going to
lamp socket, and disconnect
from the ballast. Cut and
remove terminations, keeping
lampholder wires as long as
possible.
Optical lock setscrew
Lamp Installation Instructions
8. If the old lamp has an E39 mogul base, install lamp with the supplied E26 to
E39 adapter into the luminaire socket. If the luminaire has an E26 socket, re-
move the adapter from the lamp. Refer to the Lamp Base Adapter Usage Table.
9. Install the new LED lamp, ensuring the lamp is properly seated.
5. Strip 3/8 inch from the snipped lamp holder wires (from step 3) and the
snipped AC input wires (from step 4). Using the included wire connectors,
connect the AC to the lamp holder wires as follows: If the lamp holder wires are
white and black, then connect white to white and black to black. If the lamp
holder wires are black and blue, connect AC white to lamp holder blue, connect
AC black to lamp holder black. If the lamp holder wires are white and blue,
connect AC white to lamp holder white and AC black to lampholder blue.
6. Reinstall the ballast cover plate and lamp holder. Ensure no wires are pinched
when tightening the cover screws.
4. Disconnect the AC input wires from
the ballast and cut and remove the
terminations, keeping the wires as
long as possible.
7. Open the mounting cover. Remove
the lead with fuse by disconnecting it
from the screw terminal on the quick
disconnect terminal. Discard lead with
fuse, connect lead from branch circuit
directly to the quick disconnect terminal.
Lamp holder wires
3
4
AC Input leads
7
In-line Fuse
Lamp Base Adapter Usage
Ballast Housing Adapter Utilization
H9 Use supplied adapter
10. Reinstall the optical (and guard) by rotating the optical
assembly clockwise while supporting the optical.
11. Retighten the optical lock setscrew with a small flat
blade screwdriver.
12. Refer to Table 2 for correct new label selection. The
new label specifies the replacement lamp, the hazardous
location classification area and electrical ratings. Clean
the area and then apply new label to a visible location on
the housing.
13. Restore power to the luminaire.
Powr-Gard® is a registered trademark of General Electric Company.
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information and specifications subject to change without
notice. All values are design or typical values when measured under laboratory conditions.
Page 6 of 12
(Rev 05/09/23)
LEDL090_R01
Installation GuideType B 21/35/45W LED Hazardous Rated Lamp 120-277V
Manuel d’installation
Lampe Type B DEL 21/35/45W 120-277V Classée Dangereuse
LEDL090 (A-1027119)
Taille de la lampe Profil ED17
Culot E26 avec adaptateur E39/EX39
Lampe Type B DEL
120-277V
Classée Dangereuse
AVANT DE COMMENCER
Lisez aentivement toutes ces instructions.
Conservez ces instructions pour référence future.
Risque d’électrocution ou d’incendie. Avant d’installer
ce kit dans un appareil, assurez-vous que le luminaire
correspond aux caractéristiques et dimensions données
dans les photos et que la puissance d’entrée du kit de
conversion ne dépasse pas la puissance d’entrée du
luminaire. Ce produit est de la classe 120-277 V, toutefois,
aux États-Unis ils ne devraient être utilisés que dans des
circuits de dérivation autorisés dans la section 210.6 du «
National Electrical Code » des États-Unis pour les douilles
E26/E39/EX39.
AVERTISSEMENT
AVERTISSEMENT
IL EST INTERDIT DE FAIRE OU DE MODIFIER UNE OUVERTURE
DANS UN BOÎTIER DE CÂBLAGE OU DE COMPOSANTS
ÉLECTRIQUES AU COURS DE L’INSTALLATION DU NÉCESSAIRE.
Évitez tout contact des fils avec les arêtes métalliques
ou autres objets tranchants pour éviter des dégâts ou
éraflures aux fils.
CONTACTEZ UN ÉLECTRICIEN QUALIFIÉ si vous n’êtes pas
bien au courant des luminaires et des systèmes électriques. L’installation
de ce kit de conversion DEL exige une connaissance des procédures de
sécurité, si vous nêtes pas qualifié, ne risquez pas son installation.
NE DÉCONNECTEZ PAS les fils existants des bornes du porte-lampe en vue des nouvelles connections. Coupez les fils terminaux existants
du porte-lampe à une distance valable du point de raccordement et utilisez deux connecteurs pour aacher les nouveaux fils.
LE KIT DE MODIFICATION EST DESTINÉ À MODIFIER LES LUMINAIRES IDENTIFIÉS DANS LE TABLEAU DE RÉFÉRENCE DES LUMINAIRES. CE
PRODUIT DOIT ÊTRE MIS EN PLACE PAR UN ÉLECTRICIEN QUALIFIÉ CONFORMÉMENT AUX CODES ÉLECTRIQUES APPROPRIÉS APPLICA-
BLES. ASSUREZVOUS QUE LE LUMINAIRE ACTUELLEMENT INSTALLÉ ET LES KITS DE MODIFICATION SONT INSTALLÉS UNIQUEMENT DANS
LES MÊMES EMPLACEMENTS DANGEREUX CLASSIFIÉS SPÉCIFIÉS SUR L’ÉTIQUETTE DE MARQUAGE DU KIT DE MODIFICATION.
Alimentation nominale
LED45ED17/YXX/HAZ 120-277V, 0.39 amps max, 45W
LED35ED17/YXX/HAZ 120-277V, 0.33 amps max, 35W
LED21ED17/YXX/HAZ 120-277V, 0.19 amps max, 21W
Ce kit comprend:
1. Lampe DEL
2. Étiquee pour luminaire modifié
3. Instructions d’installation
4. Connecteurs de fils (2)
5.
Adaptateur de douille E26 à E39
Outils nécessaires:
1. Tournevis droit et clé réglable
2. Coupe fil
3. Outil à dénuder
4. Petit tournevis à lame plate
REMARQUE: Le luminaire ne doit pas être enlevé de sa surface
de montage avant modification.
Tableau de référence des adaptateurs de luminaires
Adaptateur de luminaire Page
GE Lighting Filtr-Gard
®
9
Crouse-Hinds Champ
®
VMV 9
Appleton Mercmaster
®
III 10
Appleton Mercmaster
®
II 10
Hubbell Killark
®
VM Series 11
Holophane Petrolux
®
P3M 11
Thomas & Bes Hazlux
®
3 Series 12
GE Lighting Powr-Gard
®
H9 Series 12
AVERTISSEMENT
Déconnectez l’alimentation électrique du luminaire à la source.
ATTENTION
Évitez les risques de brulure – laissez refroidir le luminaire et
la lampe avant de continuer.
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information and specifications subject to change without
notice. All values are design or typical values when measured under laboratory conditions.
Page 7 of 12
(Rev 05/09/23)
LEDL090_R01
Étiquee C1 : pour les zones dangereuses de Classe I, Division 2, Groupes A, B, C, D
Étiquee C1/C2 : pour les zones dangereuses de Classe I, Division 2, Groupes A, B, C, D ; Classe II, Division 1, Groupes E, F, G ; Classe II, Division 2, Groupes F, G
Modèles 45WModèles 21W
Étiquee C2 : pour les zones dangereuses de Classe II, Division 1, Groupes E, F, G ; Classe II, Division 2, Groupes F, G
Modèles 35W
Reportez-vous au tableau 2 pour la sélection correcte de la nouvelle étiquee. La nouvelle étiquee spécifie la lampe de
remplacement, la zone de classification des emplacements dangereux et les caractéristiques électriques.
Adaptateur de luminaire Étiquee C1 Étiquee C1/C2 Étiquee C2
GE Lighting Filtr-Gard
®
Toutes les options - -
Crouse-Hinds Champ
®
VMV
Toutes les autres options G24 -
Appleton Mercmaster
®
III
Couvercles de montage avec suxe PC12D2 et PC27D2
Toutes les autres options
Appleton Mercmaster
®
II
Couvercles de montage avec suxe PC12D2 et PC27D2,
Couvercles de montage LPWB-75, LPWB-100
Toutes les autres options
-
Hubbell Killark
®
VM Series - Toutes les options -
Holophane Petrolux
®
P3M - Toutes les options -
Thomas & Bes Hazlux
®
3 Series
Couvercles de montage VS4, VS5
Toutes les autres options
-
GE Lighting Powr-Gard H9 Series
- -
Toutes les options
Tableau 2 : Guide d’application de l’étiquee du luminaire modifié
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information and specifications subject to change without
notice. All values are design or typical values when measured under laboratory conditions.
Page 8 of 12
(Rev 05/09/23)
LEDL090_R01
Manuel d’installation
Lampe Type B 21/35/45W DEL 120-277V Classée Dangereuse
Instructions de conversion des boîtiers de montage ou de ballast du
Luminaire GE Lighting Filtr-Gard® classé UL, marqués pour une utilisation
en Classe I, Division 2, Groupes A, B, C et D emplacements dangereux.
1
5
Conversion de GE Lighting Filtr-Gard®
A
3. Coupez les fils noir et blanc de la déconnection rapide vers le circuit du
ballast en laissant le maximum possible de fil aaché à la déconnection
rapide. Faites aention de laisser le fil de masse vert connecté.
4. Coupez les fils blanc (neutre) et coloré (chaud) du support de la lampe
au centre du boîtier du ballast, en laissant le maximum possible de fil at-
taché au support de la lampe.
5. Dénudez 9,5 mm des fils de la déconnection rapide qui ont été coupés (étape
3) et de fils coupés du support de la lampe (étape 4). Avec les capuchons de
connexion fournis, raccordez le blanc au blanc et le noir au coloré (peut être noir).
6. Placez la broche de charnière du boîtier du ballast sur la charnière du couvercle.
Reconnectez l’appareil de déconnection rapide principal. Assurez-vous de ne pas
coincer de fils lorsque vous resserrez les vis du couvercle.
Instructions d’Installation de la Lampe
7.
S’il y a une protection optique, enlevez-la en tournant dans le sens anti-
horlogique, ou en enlevant les vis de retenue.
8. Enlevez l’optique en tournant délicatement dans le sens anti-horlogique.
9. Enlevez l’ancienne lampe DHI et inspectez la douille pour signe d’usure
et/ou d’arc électrique. Au besoin, contactez le fabricant original du
luminaire pour des pièces de rechange.
10. Si l’ancienne lampe a une base mogul E39, installez la lampe avec
l’adaptateur E26 à E39 fourni dans la douille du luminaire. Si le luminaire a
une douille E26, retirez l’adaptateur de la lampe. Reportez-vous au tableau
d’utilisation de l’adaptateur de culot de lampe.
11. Installez la novelle lampe DEL, en vous assurant que la lampe est
correctement montée.
Fils du support de la lampe Alimentation CA vers ballast
Montage Numéro catalogue Filtr-Gard
®
Boîtier du ballast Boîtiers du ballast Séries H2
Couvercle/Montage
Montages Séries H2000
Ensemble optique Optique Séries H2000
Câblage
1.
Desserrez la vis qui retient ensemble le boîtier
du ballast et le couvercle.
2. Faites pivoter ouvert le couvercle du ballast
et séparez les deux connecteurs de plastic
noir pour séparer la fonction de déconnection
rapide située entre le couvercle et le boîtier.
12. Réinstaller l’optique et la protection (s’ils sont
fournis) dans leurs positions d’origine.
13. Reportez-vous au tableau 2 pour la sélection
correcte de la nouvelle étiquee. La nouvelle
étiquee spécifie la lampe de remplacement,
la zone de classification des emplacements
dangereux et les caractéristiques électriques.
Neoyez la zone, puis appliquez une nouvelle
étiquee à un endroit visible sur le boîtier.
14. Reconnectez l’alimentation vers le luminaire.
Filtr-Gard® est une marque déposée de
General Electric Company.
Conversion de Crouse-Hinds Champ
®
B
Instructions de conversion des boîtiers de montage/ballast des luminaires
Crouse-Hinds Champ
®
VMV Series DHI classés UL marqués pour utilisation
en Classe I, Division 2, Groupes
A, B, C, D ; Classe II, Division 1, Groupes E, F,
G ; Classe II, Division 2, Groupes F, G emplacements dangereux.
Montage Numéro catalogue Champ
®
Boîtier du ballast VMVS et VMVM
Couvercle Champ
(Module de montage)
APM2, APM3, HPM2, CM2, CM3,
TWM2, TWM3, JM5, PM5, QM25
Composants optiques et
de protection
G24, S808*, P21*, RD70*, RA70*, G241*,
G243*, G245*, P241*, R2*, R3*, R5*, P23*
Câblage
1.
Desserrez la vis qui retient ensemble le boîtier
du ballast et le couvercle.
2. Faites pivoter ouvert le couvercle du ballast.
3. Enlevez les connecteurs de fils entre les fils
d’entrée et le circuit du ballast. Faites aention
de laisser le fil de masse vert connecté.
1
4
Fils d’entrée CA
4. Enlevez les connecteurs de fils des fils du support de lampe.
5. Raccordez les fils du support de lampe aux fils d’entrée, en utilisant les
connecteurs inclus. Raccordez le blanc au blanc et le noir au noir.
6. Placez la broche de charnière du boîtier du ballast sur la charnière du
couvercle. Fermez et fixez le couvercle et le boîtier du ballast en serrant la vis
Assurez-vous de ne pas coincer de fils lorsque vous fermez le boîtier.
Instructions d’Installation de la Lampe
7. Dévissez l’ensemble optique pour enlever les protections, les globes ou les
flecteurs extérieurs.
8. Enlevez l’ancienne lampe DHI et inspectez la douille pour signe d’usure et/
ou d’arc électrique. Au besoin, contactez le fabricant original du luminaire
pour des pièces de rechange.
9. Si l’ancienne lampe a une base mogul E39, installez la lampe avec
l’adaptateur E26 à E39 fourni dans la douille du luminaire. Si le luminaire a
une douille E26, retirez l’adaptateur de la lampe. Reportez-vous au tableau
d’utilisation de l’adaptateur de culot de lampe.
5
Fils du support de lampe
10. Installez la nouvelle lampe DEL, en vous assurant que
la lampe est correctement montée.
11. Vissez l’ensemble optique sur le boîtier du ballast.
12.
Reportez-vous au tableau 2 pour la sélection cor-
recte de la nouvelle étiquee. La nouvelle étiquee
spécifie la lampe de remplacement, la zone de classifi-
cation des emplacements dangereux et les caractéris-
tiques électriques. Neoyez la zone, puis appliquez une
nouvelle étiquee à un endroit visible sur le boîtier.
13. Reconnectez l’alimentation vers le luminaire.
Champ® est une marque déposée de Eaton’s Crouse-Hinds.
Utilisation de l’adaptateur de culot de lampe
Boîtier du ballast Utilisation de l’adaptateur
H2*0 SK, H2*05L, H2* 10M Retirer l’adaptateur de la lampe
Tous les autres Utilisez l’adaptateur fourni
Utilisation de l’adaptateur de culot de lampe
Boîtier du ballast Utilisation de l’adaptateur
VMV5050, VMVM070, VMVM100 Retirer l’adaptateur de la lampe
Tous les autres Utilisez l’adaptateur fourni
* Classe I, Division 2 uniquement
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information and specifications subject to change without
notice. All values are design or typical values when measured under laboratory conditions.
Page 9 of 12
(Rev 05/09/23)
LEDL090_R01
Manuel d’installation
Lampe Type B 21/35/45W DEL 120-277V Classée Dangereuse
Conversion du Appleton Mercmaster®
C
Instructions de conversion des boîtiers montage/ballast des luminaires
Appleton Mercmaster
®
III Series DHI classés UL marqués pour utilisation
en Classe I, Division 2, Groupes A, B, C, D ; Classe II, Division 1, Groupes E, F,
G ; Classe II, Division 2, Groupes F, G emplacements dangereux.
3. Enlevez les connecteurs des fils entre les fils d’entrée et le circuit du ballast.
Déconnectez le fil d’entrée vers le fusible si l’appareil en est équipé. Le cas éché-
ant, éliminez tous les fusibles. Veillez à maintenir le fil vert de masse connecté.
4. Enlevez les connecteurs de fil des fils du support de la lampe, qui pourraient
être groupés avec d’autres fils. Tracez avec soins tous les fils du support de la
lampe. Éliminez tous fils blancs supplémentaires.
3
Fils d’alimentation CA
Montage Numéro catalogue Mercmaster
®
III
Boîtier du ballast MLBG, MLBR, KPB & KPBR
Capuchon de montage*
KPA75, KPA100, KPAF75, KPAF100, KPC75,
KPC100, KPCH75, KPCH100, KPS125, KPS150,
KPST125, KPST150, KPWB75, KPWB100
Composants optiques
et de protection
CMR-4AN/4ST, KR2-AN/ST, KRG2, KGU2,
LPG-R1/R3/R5 LPRF-2/3/4/5CP, VPGL-2HR/3HR
1
5. Raccordez les fils du support de lampe aux fils d’entrée, en utilisant les
connecteurs inclus. Raccordez le blanc au blanc et le noir au noir.
6. Placez la broche de charnière du boîtier du ballast sur la charnière du
couvercle. Fermez et fixez le couvercle et le
boîtier du ballast en serrant la vis.
Instructions d’Installation de la Lampe
7. Desserrez les vis et dévissez l’ensemble optique pour enlever les
protections, globes ou réflecteurs extérieurs.
8. Enlevez l’ancienne lampe DHI et inspectez la douille pour signe d’usure
et/ou d’arc électrique. Au besoin, contactez le fabricant original du
luminaire pour des pièces de rechange.
9. Si l’ancienne lampe a une base mogul E39, installez la lampe avec
l’adaptateur E26 à E39 fourni dans la douille du luminaire. Si le luminaire a
une douille E26, retirez l’adaptateur de la lampe. Reportez-vous au tableau
d’utilisation de l’adaptateur de culot de lampe.
10. Installez la nouvelle lampe DEL, en vous assurant que la lampe est
correctement montée.
11. Vissez l’ensemble optique dans le boîtier du ballast.
5
Fils du support de la lampe
Câblage
1.
Desserrez l’écrou qui maintient ensemble le
boîtier et le couvercle du ballast.
2. Faites pivoter ouvert le couvercle du ballast.
12.
Reportez-vous au tableau 2 pour la sélec-
tion correcte de la nouvelle étiquee. La nouvelle
étiquee spécifie la lampe de remplacement, la
zone de classification des emplacements dan-
gereux et les caractéristiques électriques. Neoyez
la zone, puis appliquez une nouvelle étiquee à un
endroit visible sur le boîtier.
13. Reconnectez l’alimentation vers le luminaire.
Mercmaster® est une marque déposée de Appleton Grp.
Conversion du Appleton Mercmaster
®
D
Instructions de conversion des boîtiers montage/ballast des luminaires
Appleton Mercmaster
®
II Series DHI classés UL marqués pour utilisation
en
Classe I, Division 2, Groupes A, B, C, D ; Classe II, Division 1, Groupes E, F,
G ; Classe II, Division 2, Groupes F, G emplacements dangereux.
Montage
Numéro catalogue Mercmaster® II
Boîtier du ballast
LPB, uniquement boîtier de 4,75 po (12,1 cm) de haut
Capuchon de montage*
LPA-75, LPA-100, LPC-75, LPC-100, LPWB-75**,
LPWB-100**, LPS-125, LPS-150
Composants optiques
et de protection
LPRF-2CG/5CG, VPGL-2HR, KGU2, KR2-ST/AN,
VPGU2, LPG-R1/R3/R5
Câblage
1.
Desserrez l’écrou qui maintient ensemble le
boîtier et le couvercle du ballast.
2. Faites pivoter ouvert le couvercle du ballast.
1
3. Enlevez les connecteurs des fils entre les fils d’entrée et le circuit du bal-
last. Veillez à maintenir le fil vert de masse connecté.
4. Repérez l’aache du fil et coupez-la, séparez le fil de la boe. Enlevez
les connecteurs de fil des fils du support de la lampe. Éliminez tout fils
blancs supplémentaires. Les fils du support de la lampe sont noir et blanc
et arrivent de la partie inférieure du boîtier du ballast. Le ballast est sous le
support au centre du boîtier.
3
Fils d’alimentation CA
5. Raccordez les fils du support de lampe aux fils d’entrée, en utilisant les
connecteurs inclus. Raccordez le blanc au blanc et le noir au noir.
6. Placez la broche de charnière du boîtier du ballast sur la charnière du cou-
vercle. Fermez et fixez le couvercle et le boîtier du ballast en serrant l’écrou.
Instructions d’Installation de la Lampe
7. Desserrez les vis et dévissez l’ensemble optique pour enlever les protec-
tions, globes ou réflecteurs extérieurs.
8. Enlevez l’ancienne lampe DHI et inspectez la douille pour signe d’usure et/
ou d’arc électrique. Au besoin, contactez le fabricant original du luminaire pour
des pièces de rechange.
9. Si l’ancienne lampe a une base mogul E39, installez la lampe avec
l’adaptateur E26 à E39 fourni dans la douille du luminaire. Si le luminaire a
une douille E26, retirez l’adaptateur de la lampe. Reportez-vous au tableau
d’utilisation de l’adaptateur de culot de lampe.
10. Installez la nouvelle lampe DEL en vous assurant que la lampe est cor-
rectement montée.
5
Fils du support de la lampe
11. Vissez l’ensemble optique dans le boîtier du ballast.
12. Reportez-vous au tableau 2 pour la sélection cor-
recte de la nouvelle étiquee. La nouvelle étiquee
spécifie la lampe de remplacement, la zone de clas-
sification des emplacements dangereux et les carac-
téristiques électriques. Neoyez la zone, puis appliquez
une nouvelle étiquee à un endroit visible sur le boîtier.
13. Reconnectez l’alimentation vers le luminaire.
Mercmaster® est une marque déposée de Appleton Grp.
* Les couvercles de montage avec le suxe “PC12D2” ou “PC27D2” sont uniquement de Classe I, Division 2
* Les couvercles de montage avec le suxe “PC12D2” ou “PC27D2” sont uniquement de Classe I, Division 2
** Classe I, Division 2 uniquement
Utilisation de l’adaptateur de culot de lampe
Boîtier du ballast Utilisation de l’adaptateur
MLBG, MLBR Retirer l’adaptateur de la lampe
KPB, KPBR Utilisez l’adaptateur fourni
Utilisation de l’adaptateur de culot de lampe
Boîtier du ballast Utilisation de l’adaptateur
LPB, uniquement boîtier de 4,75 po (12,1 cm) de haut
Utilisez l’adaptateur fourni
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information and specifications subject to change without
notice. All values are design or typical values when measured under laboratory conditions.
Page 10 of 12
(Rev 05/09/23)
LEDL090_R01
Manuel d’installation
Lampe Type B 21/35/45W DEL 120-277V Classée Dangereuse
1
Montage Killark® Catalog#
Boîtier du ballast VM1, VM2, VM3, VM4, VM5, VMLO, VMMO
Couvercle
(Module de
montage)
VMA2B, VMA3B, VMB2B, VMB3B, VMC2B, VMC3B,
VMD4B, VMD5B, VMF2B, VMF3B, VMS4B, VMS5B,
VMX2B, VMX3B, VMX6B, VMX7B, VMX8B, VMX9B
Composants
optiques et de
protection
VMG17, VMG25, VMR171, VMR175, VMR251, VMR253,
VMR255, VZRG1550, VZRG2520, VZRG2550,
VMAG17, VMAG25S, VMERG, VMRWG, VMRWG8,
VMRERG, VMPSD40, VMPA40, VMEP40, VMER40,
VMG40, VZRG4050, VZRG4020, VMAG40S
Conversion de Hubbell Killark®
E
Instructions de conversion des boîtiers de montage ou de ballast du Lumi-
naire DHI Hubell Killark® VM Series classé UL, marqués pour une utilisation
en Classe I, Division 2, Groupes A, B, C, D ; Classe II, Division 1, Groupes E, F,
G ; Classe II, Division 2, Groupes F, G emplacements dangereux.
3. Enlevez les connecteurs de fils entre les fils d’entrée et le circuit du bal-
last. Faites aention de laisser le fil de masse vert connecté.
4. Retirez les connecteurs de fils du support de la lampe.
3
Fils d’entrée CA
5. Raccordez les fils du support de la lampe aux fils d’entrée, avec les con-
necteurs de fils inclus. Connectez le fil blanc au connecteur blanc et le fil
noir au connecteur noir.
6. Placez la broche de charnière du boîtier du ballast sur la charnière du
couvercle. Fermez et fixez le couvercle et le boîtier du ballast en serrant la
vis. Assurez-vous de ne pas coincer de fils lorsque vous resserrez les vis
du luminaire.
Instructions d’installation de la lampe
7. Dévissez l’ensemble optique pour enlever les protections, globes ou
flecteurs extérieurs.
8. Enlevez l’ancienne lampe DHI et inspectez la douille pour signe d’usure
et/ou d’arc électrique. Au besoin, contactez le fabricant original du lumi-
naire pour des pièces de rechange.
9. Si l’ancienne lampe a une base mogul E39, installez la lampe avec
l’adaptateur E26 à E39 fourni dans la douille du luminaire. Si le luminaire a
une douille E26, retirez l’adaptateur de la lampe. Reportez-vous au tableau
d’utilisation de l’adaptateur de culot de lampe.
5
Fils du support de la lampe.
Câblage
1.
Desserrez la vis qui retient ensemble le boîtier
du ballast et le couvercle.
2. Faites pivoter ouvert le couvercle du ballast.
10. Installez la nouvelle lampe DEL, en vous assurant que
la lampe est correctement montée.
11. Vissez l’ensemble optique dans le boîtier du ballast.
12. Reportez-vous au tableau 2 pour la sélection correcte
de la nouvelle étiquee. La nouvelle étiquee spécifie
la lampe de remplacement, la zone de classification
des emplacements dangereux et les caractéristiques
électriques. Neoyez la zone, puis appliquez une
nouvelle étiquee à un endroit visible sur le boîtier.
13. Reconnectez l’alimentation vers le luminaire.
Conversion de Holophane Petrolux
®
P3M
F
Instructions de conversion des boîtiers de montage ou de ballast du Luminaire DHI
Holophane Petrolux
®
P3M Series classé UL, marqués pour une utilisation en Classe
I, Division 2, Groupes A, B, C, D pour les États-Unis et le Canada; Classe II, Division 1,
Groupes E, F, G ; Classe II, Division 2, Groupes F, G emplacements dangereux pour
les États-Unis uniquement.
Montage Holophane P3M Refractor
Boîtier du ballast
Source DHI, 50-175W HPS ou MH
Couvercle de montage
ST, WL, PD, CE, UN
Composants d’optique
541, 545, GD
Câblage
1.
Desserrez la vis qui retient ensemble le boîtier
du ballast et le couvercle.
2. Ouvrez le couvercle du lest avec la charnière.
3. Enlevez les connecteurs des fils entre les fils d’entrée et le circuit du bal-
last. Déconnectez le fil d’entrée vers le fusible si l’appareil en est équipé. Le
cas échéant, éliminez tous les fusibles. Faites aention de laisser le fil de
masse vert connecté.
4. Enlevez les connecteurs de fil des fils du support de la lampe, qui pour-
raient être groupés avec d’autres fils. Suivez soigneusement tous les fils
depuis le support de la lampe. Déconnectez tous les fils supplémentaires
des fils blanc et noir du support de la lampe.
3
Fils d’entrée CA
5
Fils du support de la lampe
5. Raccordez les fils du support de lampe aux fils d’entrée, en utilisant les
connecteurs inclus. Raccordez le blanc au blanc et le noir au noir.
6. Placez la broche de charnière du boîtier du ballast sur la charnière du cou-
vercle. Fermez et fixez le couvercle et le boîtier du ballast en serrant la vis.
Instructions d’installation de la lampe
7. Retirez l’ensemble optique en tournant les paes noires autour de l’optique
dans le sens inverse des aiguilles d’une montre.
8. Enlevez l’ancienne lampe DHI et inspectez la douille pour signe d’usure et/
ou d’arc électrique. Au besoin, contactez le fabricant original du luminaire
pour des pièces de rechange.
9. Si l’ancienne lampe a une base mogul E39, installez la lampe avec
l’adaptateur E26 à E39 fourni dans la douille du luminaire. Si le luminaire a
une douille E26, retirez l’adaptateur de la lampe. Reportez-vous au tableau
d’utilisation de l’adaptateur de culot de lampe.
10. Installez la nouvelle lampe DEL, en vous
assurant que la lampe est correctement montée.
11. Vissez l’ensemble optique dans le boîtier du ballast.
12. Reportez-vous au tableau 2 pour la sélection
correcte de la nouvelle étiquee. La nouvelle
étiquee spécifie la lampe de remplacement,
la zone de classification des emplacements
dangereux et les caractéristiques électriques.
Neoyez la zone, puis appliquez une nouvelle
étiquee à un endroit visible sur le boîtier.
13. Reconnectez l’alimentation vers le luminaire.
Utilisation de l’adaptateur de culot de lampe
Boîtier du ballast Utilisation de l’adaptateur
VM1, VM2 Retirer l’adaptateur de la lampe
VM3, VM4, VM5, VMLO, VMMO Utilisez l’adaptateur fourni
Utilisation de l’adaptateur de culot de lampe
Boîtier du ballast Utilisation de l’adaptateur
Source MH (douille E26) Retirer l’adaptateur de la lampe
Source HPS ou MH (douille E39) Utilisez l’adaptateur fourni
1
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information and specifications subject to change without
notice. All values are design or typical values when measured under laboratory conditions.
Page 11 of 12
(Rev 05/09/23)
LEDL090_R01
Manuel d’installation
Lampe Type B 21/35/45W DEL 120-277V Classée Dangereuse
Conversion de Thomas & Bes Hazlux®
G
Instructions de conversion des boîtiers de montage ou de ballast du Luminaire
DHI Thomas & Bes Hazlux
®
3 Series classé UL, marqués pour une utilisation
en
Classe I, Division 2, Groupes A, B, C, D ; Classe II, Division 1, Groupes E, F, G
; Classe II, Division 2, Groupes F, G emplacements dangereux.
Montage
Numéro catalogue Thomas & Bes Hazlux®
Boîtier du ballast
DS, DH
Couvercle de
montage
VA2, VA3, VB2, VB3, VC2, VC3, VF2, VF3, VL4, VL5,
VP2, VP3, VS4*, VS5*
Composants
optiques et de
protection
VGT22, VGT22TS, VGT31S, VGT31STS, VRF22C5, VRF31C5,
VGL31R1, VGL31R3, VGL31R5, VR31CB, VGR48, VGR64, VGU22,
VGU22P, VGU31R, VGU31RP, VRA22P, VR22P, VR31P, VRA31P
3
Fils d’entrée CA
3. Enlevez les connecteurs des fils entre les fils d’entrée et le circuit du bal-
last. Déconnectez le fil d’entrée vers le fusible si l’appareil en est équipé. Le
cas échéant, éliminez tous les fusibles. Faites aention de laisser le fil de
masse vert connecté.
4. Enlevez les connecteurs de fil des fils du support de la lampe, qui pour-
raient être groupés avec d’autres fils. Suivez soigneusement tous les fils
depuis le support de la lampe. Déconnectez tous les fils supplémentaires
des fils blanc et noir du support de la lampe.
Ces instructions ne prétendent pas couvrir tous les détails ou variantes de l’équipement ni couvrir toutes les conditions possibles à satisfaire en rapport avec l’installation,
l’opération ou l’entretien. Si des informations supplémentaires sont souhaitées sur des aspects qui ne sont pas susamment couverts pour satisfaire les besoins du client,
ou si des problèmes particuliers se présentent, veuillez addresser ces questions à Current.
5. Raccordez les fils du support de lampe aux fils d’entrée, en utilisant les
connecteurs inclus. Raccordez le blanc au blanc et le noir au noir.
6. Placez la broche de charnière du boîtier du ballast sur la charnière du cou-
vercle. Fermez et fixez le couvercle et le boîtier du ballast en serrant la vis.
Instructions d’installation de la lampe
Instructions d’installation de la lampe
7. Desserrez les vis et dévissez l’ensemble optique pour enlever les protec-
tions, globes ou réflecteurs extérieurs.
8. Enlevez l’ancienne lampe DHI et inspectez la douille pour signe d’usure et/
ou d’arc électrique. Au besoin, contactez le fabricant original du luminaire pour
des pièces de rechange.
9. Si l’ancienne lampe a une base mogul E39, installez la lampe avec
l’adaptateur E26 à E39 fourni dans la douille du luminaire. Si le luminaire a
une douille E26, retirez l’adaptateur de la lampe. Reportez-vous au tableau
d’utilisation de l’adaptateur de culot de lampe.
5
Fils du support de la lampe
Câblage
1.
Desserrez le boulon qui retient ensemble le
boîtier du ballast et le couvercle.
2. Faites pivoter ouvert le couvercle du ballast.
10. Installez la nouvelle lampe DEL, en vous assurant que la
lampe est correctement montée.
11. Vissez l’ensemble optique dans le boîtier du ballast.
12. Reportez-vous au tableau 2 pour la sélection correcte
de la nouvelle étiquee. La nouvelle étiquee spécifie
la lampe de remplacement, la zone de classification
des emplacements dangereux et les caractéristiques
électriques. Neoyez la zone, puis appliquez une nouvelle
étiquee à un endroit visible sur le boîtier.
13. Reconnectez l’alimentation vers le luminaire.
* Classe I, Division 2 uniquement
Conversion de GE Lighting Powr-Gard®
H
Instructions de conversion des boîtiers de montage ou de ballast du Luminaire GE
Lighting Powr-Gard
®
classé UL, marqués pour une utilisation en Classe II, Division
1, Groupes E, F, G ; Classe II, Division 2, Groupes F, G emplacements dangereux.
Montage
Numéro catalogue Powr-Gard
®
Boîtier du ballast
Boîtiers de ballast de la série H9
Couvercle/Montage
3C, 3F, 3P, 3W, 4C, 4F, 4P, 4W, 5J, 5S
Composants optiques
et de protection JJ, JN, GG, GN
Câblage
1. Desserrez la vis de serrage avec un petit
tournevis plat et retirez l’ensemble optique
en tournant dans le sens inverse des
aiguilles d’une montre.
2. Enlevez l’ancienne lampe DHI et
inspectez la douille pour signe d’usure et/
ou d’arc électrique. Au besoin, contactez
le fabricant original du luminaire pour des
pièces de rechange.
1
3. Retirez la plaque de protection
du ballast. Localisez les fils
raccordés à la douille de la lampe
et déconnectez-les du ballast.
Coupez et retirez les terminaisons,
en gardant les fils de la douille
aussi longs que possible.
Vis de serrage du
verrou d’optique
Instructions d’installation de la lampe
8. Si l’ancienne lampe a un culot Goliath E39, installez la lampe dans la
douille du luminaire avec l’adaptateur E26 à E39 fournis. Si le luminaire
a une douille E26, enlevez l’adaptateur de la lampe. Consultez le tableau
d’Utilisation d’adaptateur de base de lampe.
9. Installez la nouvelle lampe DEL, en vous assurant que la lampe est correctement montée.
10. Réinstallez l’optique (et la protection) en tournant l’ensemble optique dans le sens
fils coupés d’entrée CA (à l’étape 4). À l’aide des connecteurs de fils inclus, connectez
le courant alternatif aux fils du support de la lampe de la manière suivante: si les fils
du support de la lampe sont blancs et noirs, connectez alors le blanc au blanc et le
noir au noir. Si les fils du support de la lampe sont noirs et bleus, connectez le fil CA
blanc au support de la lampe bleu, connectez le fil CA noir au support de la lampe
noir. Si les fils du support de la lampe sont blancs et bleus, connectez le fil CA blanc
au support de la lampe blanc et le fil CA noir au support de la lampe bleu.
6. Réinstallez la plaque de protection du ballast et le support de la lampe. Assurez-
vous de ne pas coincer de fils lorsque vous resserrez les vis du couvercle.
4. Déconnectez les fils d’entrée CA
du ballast puis coupez et retirez les
terminaisons, en gardant les fils aussi
longs que possible.
5. Dénudez 9,5 mm des fils coupés du
support de la lampe (à l’étape 3) et des
7. Ouvrez le couvercle de montage. Re-
tirez le câble avec fusible en le débran-
chant de la borne à vis sur la borne
à déconnexion rapide. Jetez le câble
avec le fusible, connectez le câble du
circuit de dérivation directement à la
borne de déconnexion rapide.
Fils du support de la lampe
3
4
Fils d’entrée CA
7
Fusible en ligne
des aiguilles d’une montre tout en soutenant l’optique.
11. Resserrez la vis de serrage du verrou d’optique avec
un petit tournevis plat.
12. Reportez-vous au tableau 2 pour la sélection correcte
de la nouvelle étiquee. La nouvelle étiquee spécifie
la lampe de remplacement, la zone de classification
des emplacements dangereux et les caractéristiques
électriques. Neoyez la zone, puis appliquez une nouvelle
étiquee à un endroit visible sur le boîtier.
13. Reconnectez l’alimentation vers le luminaire.
Powr-Gard® is a registered trademark of General Electric Company.
1
Utilisation de l’adaptateur de culot de lampe
Boîtier du ballast Utilisation de l’adaptateur
Source MH (douille E26) Retirer l’adaptateur de la lampe
Source HPS ou MH (douille E39) Utilisez l’adaptateur fourni
Utilisation de l’adaptateur de culot de lampe
Boîtier du ballast Utilisation de l’adaptateur
H9 Utilisez l’adaptateur fourni
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information and specifications subject to change without
notice. All values are design or typical values when measured under laboratory conditions.
Page 12 of 12
(Rev 05/09/23)
LEDL090_R01
Manuel d’installation
Lampe Type B 21/35/45W DEL 120-277V Classée Dangereuse
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Current LEDL090 Guide d'installation

Taper
Guide d'installation

dans d''autres langues