IMPORTANT:
Go to www.extron.com for the
complete user guide
, installation
instructions, and specifications.
Cable Cubby 1202 and 1402 • Installation Guide
This guide provides instructions for an experienced technician to install and connect the
Extron Cable Cubby 1202 and 1402.
The Cable Cubby units are furniture-mounted enclosures for cable access, connections,
and AC power. Cables that are not in use can be stored out of the way while
remaining connected to the presentation system.
NOTE: This product is intended for use only with Extron UL listed
power modules (not included).
Planning
Check with local and state regulations before starting the
installation
Ensure that the planned installation complies with national and local building and electrical codes.
Ensure that the planned installation complies with the Americans with Disabilities Act or other accessibility requirements.
Check all parts and equipment before installation
Ensure that all parts are present in each kit.
Ensure that necessary tools and equipment are available for the installation.
Kit Contents
Cable Cubby 1202
Cable Cubby 1402
1 2
4 8
1 2
1 2
6 (3/8"), 2 (1/4") 12 (3/8"), 4 (1/4")
1 2
1 2
8 16
#4-40 Module Screws
#6 Pan-head Mounting
Screws and Star Washers
AAP Frame Plate
Cable Grommet Plate
Hole Plugs
Retractor Pin & Clip
Connectivity
Bracket
#4-40 Module Screws
AAP Frame Plate
Cable Grommet
Plate
Hole Plugs
Retractor
Bracket
Retractor
Pin & Clip
#6-32 Mounting
Screws and Star
Washers
2
Cable Cubby 1202 and 1402 • Installation Guide (Continued)
Preparing the Cable Cubby
Step 1 — Assemble Connectivity Modules
Connectivity modules allow you to populate the Cable Cubby enclosure with a combination of AAPs, cable pass-through, or
Retractors. Follow the steps below to assemble the connectivity modules of your choice.
Option 1: AAP Module
Preparing the Table
Cut a hole in the surface where the enclosure will be installed. Read the following information before making a cut.
Determine the best location for the enclosure
Ensure that the location where the Cable Cubby is to be installed is convenient for as many users as possible.
Ensure that the edge on which the lid opens is oriented correctly.
Ensure that there is ample space under the table for cables. Allow at least 36 inches of cable loop for each cable (see
Routing and Connecting Cables on page 6).
When installing Retractors in the Cable Cubby, ensure that there is enough space for the Retractor assembly under the table
or furniture (see the Cable Retractor Series/2 Installation Guide for Retractor dimensions).
Choose a method for cutting the hole in the table
CAUTION: Wear safety glasses when operating power equipment. Failure to comply can result in eye injury.
ATTENTION : Portez des lunettes de sécurité lorsque vous utilisez l’équipement électrique. Ne pas respecter cela peut
conduire à une blessure à l’oeil.
ATTENTION: The opening in the table for the Cable Cubby should be cut only by licensed and bonded craftspeople.
Exercise care to prevent scarring or damaging the furniture.
ATTENTION : L’ouverture dans la table pour le CableCubby devrait être coupée seulement par des artisans autorisés et
qualiés. Faites attention à ne pas faire de marques sur le meuble et à ne pas l’endommager.
Choose one of the following methods for cutting the hole:
Hand Router and Routing Template Jigsaw and Paper Cut-Out Template CNC Wood Router
If using a CNC wood router or other
precise machinery, use the exact
cut-out dimensions for your model
(see the table below).
Visit www.extron.com for Cable Cubby routing
template part numbers and instructions.
Dimensions and cut-out templates are
available online at www.extron.com.
Product
Cut-out Dimensions
User Access
Width
Side
Dimension
CC 1202 10.00"
(254.0 mm)
4.00"
(101.6 mm)
CC 1402 10.00"
(254.0 mm)
6.75"
(171.5 mm)
Cut-Out Template for the Extron
Cable Cubby 1200
Outer Edge of Front Bezel
(Do not cut this line.)
1. Confirm the product to be installed.
2. Remove the surface cut-out area
(gray) from the template.
3. Measure the cutout and template.
4. Mark the position on the
furniture where the Cable Cubby 1200
will be installed.
5. Double check the dimensions and position,
then cut the opening.
Trim Ring
Lip
Cut-Out Radius:
0.25" (0.6 cm)
User Access
P/N 68-2472-01 Rev. A
Page Size: 11" x 17"
Print Scale 1:1
Do not Shrink
NOTE: After assembling the module, proceed to Step 2 — Install the Modules on page 4.
Secure the AAP plate
on the connectivity brackets
using four of the provided
module screws.
3
2
Insert cables through the bottom
of the connectivity bracket.
Connect cables to the AAPs.
Secure up to three single space
AAPs in the AAP panel.
#4-40 Nut with
Captive Washer
1
3
Option 2: Cable Pass-Through Module
Option 3: Retractor Bracket
Use the Retractor Bracket to mount Retractors in the Cable Cubby enclosure. There are two options for installing the bracket
(Options 3a and 3b, below).
NOTE: If installing more than one bracket in the Cable Cubby 1402, see Retractor Configuration for
Cable Cubby 1402 on page 6.
NOTE: After assembling the module, proceed to Step 2 — Install the Modules on the next page.
NOTES:
After installing the bracket, proceed to Step 2 — Install the Modules on the next page to install the power module.
After mounting the Cable Cubby on the table, install the Retractors (see Installing Retractors on page 5).
Option 3a
Use this option for the Cable Cubby 1202, and for vertical
or angular Retractor mounting in a Cable Cubby 1402.
Option 3b
Use this option for horizontal Retractor mounting in a
Cable Cubby 1402 only.
Insert the bracket as shown.
The bracket may be
installed on the left or right
side of the enclosure and must
be installed at the lowest height.
1
Secure the bracket using four of
the provided pan-head mounting
scr
the screws using a screwdriver.
2
Insert the bracket as shown.
The bracket may be
installed on the left or right
side of the enclosure and must
be installed at the lowest height.
1
Secure the bracket using four of
the provided pan-head mounting
scr
ews with star washers. Tighten
the screws using a screwdriver.
2
Secure the grommet plate on
the connectivity bracket
using four of the provided
module screws.
Insert cables through
the bottom of the connectivity
bracket and into the holes of
the grommet plate.
Snap the included
hole plugs into any
unused holes.
3
2
1
4
Cable Cubby 1202 and 1402 • Installation Guide (Continued)
Mounting the Cable Cubby in the Table
Step 1 — Mount the Cable Cubby flush with the table
CAUTION: The anged edges of the top of the surface enclosure are sharp. These edges are also soft and may be easily
nicked or bent. Exercise caution when handling the enclosure to prevent personal injury or damage to the enclosure.
ATTENTION : Les extrémités à brides du haut de la surface du boîtier sont aiguisées. Ces extrémités sont aussi lisses et
peuvent facilement être coupées ou pliées. Soyez prudents lorsque vous manipulez le boîtier an d’éviter de l’endommager
ou de vous blesser.
Step 2 — Install the Modules
Determine where the connectivity modules and power module will be installed in the Cable Cubby. The modules may be installed
on the left or right side of the enclosure and at various heights.
NOTES:
Ensure that there is enough room above the modules for the Cable Cubby lid to close completely.
Use a screwdriver to secure the modules with the screws.
WARNING: Risk of Electric Shock. To ensure proper electrical
grounding, use the provided #6-32 mounting screws with the star
washers.
AVERTISSEMENT : Risque de choc électrique. An
d’assurer une mise à la terre correcte, utilisez les xations de mise
à la terre #6-32 et les rondelles en étoile fournies.
125V~ 12A MAX TOTAL
Secure the modules using four of the provided pan-head mounting scr
ews and star washers.
Insert the modules
into the Cable Cubby.
125V~ 12A MAX
TOTAL
2
1
Remove the plastic
strips and lm on the
surface of the
Cable Cubby.
Ensure that the
side clamps are
seated against the
enclosure.
Lower the Cable Cubby into
the hole to test the t.
If necessary, carefully
enlarge the opening.
3
1
2
s
t
ic
n th
e
h
e
a
re
s
t t
h
e
Low
e
t
he
h
If
ne
c
en
l
a
r
3
5
Step 2 — Under the table, adjust the side clamps on the enclosure
Installing Retractors
Follow the steps below to install Retractors. For horizontal or angular Retractor
mounting, see the information at right,
then follow the steps below.
NOTE: To lower the side
clamp, turn the lever
down, then press and hold
the locking plate while
sliding down the clamp.
Locking
Plat
e
Insert the pin through the
Retractor mounting hole on
the side of the Cable Cubby
and Retractor assembly.
Secure the clip
on the pin.
Insert Retractors into
the Retractor bracket.
Secure the locking screw
on each Retractor. Do not
overtighten.
2
1
4
3
p
Pin
Clip
Rotate the side clamp
outward and ensure that
the lever is down.
Slide the clamp all the
way up against the bottom
of the table.
Ensure the Cable Cubby
is rmly seated in the table.
Raise the lever to secure
the Cable Cubby.
Lever
21 3
Angular Mounting
Remove the enclosure screws as shown above, then follow
this step:
Horizontal Mounting
See the Cable Retractor Series/2 Setup Guide, available on
the Extron website, for additional steps.
Remove two enclosure screws
(one on each side) from this position.
Then, mount the Retractors as shown
at left.
Cable Release
Assembly
Move the cable release assembly upward until
the angular mounting hole is visible. Reinstall the
enclosure screws in this hole (both sides).
Remove two enclosure screws
(one on each side) from this position.
Then, mount the Retractors as shown
at left.
Cable Release
Assembly
Move the cable release assembly upward until
the angular mounting hole is visible. Reinstall the
enclosure screws in this hole (both sides).
6
68-3105-01 Rev. B
07 18
Installation Checklist
Planning (page 1)
Check with local and state regulations before starting the installation
Check all parts and equipment before installation
Preparing the Table (page 2)
Determine the best location for the enclosure
Choose a method for cutting the hole in the table
Preparing the Cable Cubby (page 3)
Assemble Connectivity Modules
Install the Modules (page 4)
Mounting the Cable Cubby in the Table (page 4)
Mount the Cable Cubby ush with the table
Installing Retractors (page 5)
Routing and Connecting Cables (page 6)
Routing and Connecting Cables
For cable pass-through applications,
allow at least 36 inches (0.9 m) of cable
loop for each cable.
Connect cables to the AV system
and connect the AC power cord.
Using zip ties, secure cables to the holes
on the bottom of the Cable Cubby.
3
2
1
CAUTION:
Risk of Electric Shock.
This equipment must be grounded.
ATTENTION :
Risque de choc électrique.
Cet équipement doit être xé au sol.
NOTE: Ensure that there is no tension on the power cable.
Vertical or angular mounting:
The included brackets must be installed
diagonally in the enclosures as shown at right.
Horizontal mounting:
Install the brackets as shown below.
NOTE: Retractors may also
be mounted using the Quad
Bracket (see www.extron.com
for part numbers).
Retractor Configuration for Cable Cubby 1402
© 2017-2018 Extron Electronics — All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com
Cable Cubby 1402
Side View
Horizontal Mounting
Cable Cubby 1402
Side View
Angular
Mounting
Vertical
Mounting
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Extron Cable Cubby 1202 Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues